Frigidaire 242046800 Refrigerator User Manual

image

Contents

1. 20 4 Gently place dryer door face down on flat covered work surface 5 Locate the 5 indented head screws no 1 5 in the small circular recesses at 11 1 4 6 and 8 o clock positions of the inner door Remove and save these 5 screws mA IMPORTANT Do not attempt to remove the 2 tamper resistant screws that hold the inner glass in place 6 Locate the 2 pan head screws no 6 7 on the inner door nearest the metal strike and center of hinge 9 and 3 o clock positions Remove and save these 2 screws 7 Separate inner door assembly from outer door assembly REVERSING DOOR Reversing the hinge 1 Carefully pull out the 2 small round hole plugs from 4 From the back side of the inner door pinch the the front panel and save Remove and save the retaining tabs of the plastic square plug to release square T slot cover by sliding it up and pulling it Save square plug for reinstallation it out Move all 3 plugs to the opposite side of the front panel and insert ROUND PLUG SQUARE PLUG le ROUND PLUG 5 Carefully remove the 2 round plugs from the inner 2 Turn inner door assembly over to expose retaining door and move them to the opposite holes and tabs of metal strike Grip tabs fully with pliers to reinstall remove Discard old metal strike 6 Rotate the hinge and move it to the opposite side of the inner door Attach it with the 2 pan head 3
2. _ 27 0 68 5cm to front of closed door electrical 71 5 supply on 182cm rear of unit water supply connection on rear of unit centerline gas supply height for F rear vent e pipe on rear of gas unit io power cord on 37 rear of unit 94cm drain hose on rear of unit 39 99cm To obtain these minimal depth dimensions dryer must be vented straight back Using a quick turn 90 elbow right adds approximately 0 75 in 2 cm to installation depth Upward venting of exhaust on stacked dryer adds approximately 4 in 10 2 cm to installation depth Downward venting of exhaust on stacked dryer adds approximately 2 25 in 6 5 cm to installation depth Leftward venting of exhaust on stacked dryer adds approximately 3 75 in 9 5 cm to installation depth tHot and cold inlet hose length approximately 43 inches 109cm Power supply cord length approximately 60 inches 152 5cm 3Drain hose length approximately 52 inches 132cm 1 1 INSTALLATION INSTRUCTIONS Electrical installation The following are specific requirements for proper and safe electrical installation of your dryer Failure to follow these instructions can create electrical shock and or a fire hazard 4 WARNING ELECTRI CAL SHOCK HAZARD e This appliance MUST be properly grounded Electrical shock can result if the dryer is not properly grounded Follow the instructions in this manual for proper
3. 19 0 48cm lt g 13 50 34 5cm hacia el centro de la ventilaci n trasera ama 21 0 68 5cm suministro el ctrico en la parte trasera de la unidad altura de la l nea central para ventilaci n trasera manguera de drenaje en la parte trasera de la lavadora manguera de drenaje en la parte trasera de la lavadora 39 99cm Para obtener estas dimensiones m nimas de profundidad la secadora debe ser ventilada derecho hacia atr s Si se usa un codo de 90 hacia la derecha se agregan aproximadamente 0 75 2 cm a la profundidad de instalaci n Si se orienta el escape de la secadora instalada sobre la lavadora hacia arriba la profundidad de instalaci n aumentar aproximadamente en 4 10 2 cm Si se orienta el escape de la secadora instalada sobre la lavadora hacia abajo la profundidad de instalaci n aumentar aproximadamente en 2 25 6 5 cm Si se orienta el escape de la secadora instalada sobre la lavadora hacia la izquierda la profundidad de instalaci n aumentar aproximadamente en 3 75 9 5 cm lLa longitud de las mangueras de admisi n de agua caliente y fr a es de aproximadamente 48 5 123 cm La longitud del cable de alimentaci n es de aproximadamente 60 152 5 cm 3La longitud de la manguera de desag e es de aproximadamente 59 150 cm 3 5 Instalaci n el ctrica Los siguientes son requisitos necesarios para la instalaci n el c
4. 85 Accesorios anaa maa t coe eee EERE eee 48 www frigidaire com EE UU 1 800 944 9044 www frigidaire ca Canada 1 800 265 8352 INSTRUCCIONES IMPORTANTES DE SEGURIDAD 4 ADVERTENCIA Para su seguridad debe seguir la informaci n de esta gu a para minimizar el riesgo de incendio o explosi n o para evitar da os a la propiedad lesiones personales o incluso la muerte No almacene ni utilice gasolina ni otros l quidos o vapores inflamables cerca de este o de cualquier otro electrodom stico 4 ADVERTENCIA PELIGRO DE INCENDIO Lea las siguientes instrucciones antes de instalar y utilizar este electrodom stico e Despu s de desembalar la secadora destruya los cartones y las bolsas de pl stico Los ni os podr an utilizarlos para jugar Los cartones cubiertos con alfombras cubrecamas o l minas de pl stico pueden convertirse en c maras de aire herm ticamente cerradas y provocar asfixia Coloque todos los materiales en un basurero o mant ngalos fuera del alcance de los ni os La instalaci n y el servicio de la secadora de ropa deben ser llevados a cabo por un instalador calificado agencia de servicios o proveedor de gas Instale la secadora de ropa de acuerdo con las instrucciones del fabricante y los c digos locales La reparaci n el ctrica de la secadora debe cumplir con los c digos y las ordenanzas locales y la ltima edici n del C digo El ctrico Nacional National Electrical Code el ANSI NFPA 70 o bien en Canad
5. ADVERTENCIA PELIGRO DE EXPLOSI N Las tuber as de cobre sin recubrimiento se corroen al exponerse al gas natural lo que provoca p rdidas de gas Utilice SOLAMENTE tuber as de hierro negro acero inoxidable o lat n plastificado para el suministro de gas 1 La instalaci n DEBE realizarse de acuerdo con los c digos locales o en ausencia de ellos con el C digo de Gas Nacional National Fuel Gas Code ANSI Z223 1 ltima edici n 2 La l nea de suministro de gas debe ser un tubo de 1 27 cm 1 2 pulgada 3 Silos c digos lo permiten se puede utilizar un tubo de metal flexible para conectar la secadora a la l nea de suministro de gas La tuber a DEBE ser de acero inoxidable o de lat n plastificado 4 La l nea de suministro de gas DEBE tener REQUISITOS DE INSTALACI N Tomacorriente con puesta a tierra No corte retire ni deshabilite la clavija de conexi n a tierra bajo ninguna circunstancia Cord n el ctrico de 3 clavijas con puesta atierra una v lvula de cierre individual instalada de conformidad con el C digo de Instalaci n de Gas Natural y Propano B149 1 Se DEBE instalar una derivaci n N P T de 0 32 cm 1 8 pulgadas con tap n roscado que permita conectar un medidor de prueba inmediatamente despu s de la conexi n de suministro de gas a la secadora en contracorriente al flujo de gas La secadora DEBE estar desconectada de la tuber a de gas durante cualquier prueba en la que la
6. 10 5 cm installation INSTALLATION REQUIREMENTS Manufactured or mobile home installation 1 Installation MUST conform to current Manufactured Home Construction amp Safety Standard Title 24 CFR Part 32 80 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or Standard CAN CSAZ240 MH 2 Dryer MUST be exhausted outside outdoors not beneath the mobile home using metal ducting that will not support combustion Metal ducting must be 4 inches 10 16 cm in diameter with no obstructions Rigid metal duct is preferred 3 If dryer is exhausted through the floor and area beneath the mobile home is enclosed the exhaust Clearance requirements 4 WARNING EXPLOSION HAZARD Do not install the dryer where gasoline or other flammables are kept or stored If the dryer is installed in a garage it must be a minimum of 18 inches 45 7 cm above the floor Failure to do so can result in death explosion fire or burns system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure Refer to previous sections in this guide for other important exhaust venting system requirements When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet Installer MUST anchor this 1 dryer or 2 dryer mounted on pedestal to the floor with app
7. el CSA C22 1 del C digo El ctrico de Canad Canadian Electrical Code Parte 1 El servicio de gas de la electrodom stico debe cumplir con los c digos y las ordenanzas locales y la ltima edici n del C digo de Gas Nacional National Fuel Gas Code el ANSI Z223 1 o bien en Canad el CAN CGA B149 1 2000 Se debe instalar una v lvula de cierre individual manual a una distancia no mayor a 1 83 m 6 pies de la secadora de conformidad con el C digo Nacional de Gas Combustible ANSI Z223 1 NFPA 54 La secadora se dise conforme a los c digos ANSI Z 21 5 1 0 ANSI UL 2158 CAN CSA C22 2 N 2 112 ltimas ediciones solo para USO DOMESTICO No se recomienda esta secadora para uso comercial como por ejemplo en restaurantes salones de belleza etc No utilice materiales de ventilaci n de pl stico ni de papel de aluminio flexibles para instalar la secadora de ropa Por lo general dichos materiales se desarman se deterioran con facilidad y acumulan pelusa Estas condiciones obstruyen el flujo de aire de la secadora y aumentan el riesgo de incendio Las instrucciones de esta gu a y todo el material que se incluye con esta secadora no tienen como prop sito cubrir todas las condiciones y situaciones que puedan presentarse Cuando instale opere o repare cualquier artefacto DEBE tener cuidado y hacer uso de buenas pr cticas de seguridad QU HACER SI SIENTE OLOR A GAS a e No intente encender ning n electrodom stico A PRECAUCI ON e No
8. 4 Vuelva a instalar los tornillos de cabeza alomada no 6 7 retirados anteriormente Tenga cuidado de no da ar la rosca de los agujeros de pl stico 5 Ubique el nuevo pestillo de metal proporcionado con los manuales de la secadora Sostenga el pestillo nuevo con alicates como se muestra abajo Inserte firmemente el pestillo de manera que quede en posici n vertical INVERSI N DE LA PUERTA Reinstalaci n de la puerta 3 Cierre la puerta y verifique que la bisagra el 1 Mientras sostiene la puerta con ambas manos introduzca la pieza en forma de T que se pestillo y el gancho funcionan correctamente encuentra en la parte trasera de la bisagra en la ranura en forma de T del panel delantero y baje la puerta para alinear los agujeros de instalaci n PIEZA EN FORMA DE RANURA EN FORMA DE T EN EL PANEL T EN LA BISAGRA DE LA PUERTA DELANTERO 2 Mientras apoya la puerta instale el tornillo de cabeza alomada superior primero y luego el inferior L NOTA Los tornillos instalados correctamente presionar n la bisagra hasta que quede al ras del panel delantero Cualquier espacio que quede entre la bisagra y el pa nel delantero har que el pestillo y el gancho queden desalineados 4 ACCESORI OS PEDESTAL DE ALMACENAMI ENTO CONCORDANTE Pedestal de color blanco P N CFPWD15W Pedestal de color azu
9. la puerta interior Retire y guarde estos 5 tornillos 3 Mientras sostiene la puerta con ambas manos levante la puerta y la bisagra derecho hacia arriba aproximadamente 3 8 10 mm de manera que la pieza en forma de T pueda pasar por la ranura en forma de T en el panel delantero RANURA EN FORMA DE T EN EL PANEL DELANTERO PIEZA EN FORMA DE T EN LA BISAGRA DE LA PUERTA IMPORTANTE No intente retirar los 2 tornillos irremovibles que sostienen el vidrio en su lugar 6 Ubique los 2 tornillos de cabeza alomada no 6 7 en la puerta interior cerca del pestillo de metal y del centro de la bisagra en las posiciones relativas al reloj de las 9 y 3 Retire y guarde estos 2 tornillos 7 Separe el conjunto de la puerta interior del conjunto de la puerta exterior 44 Inversion de la bisagra 1 Retire cuidadosamente los dos tapones redondos del panel delantero y gu rdelos Retire y guarde la cubierta cuadrada de la ranura en forma de T desliz ndola hacia arriba y tirando de ella para retirarla Mueva los 3 tapones al lado opuesto del panel delantero TAP N REDONDO TAP N CUADRADO Lo TAP N REDONDO 2 Voltee el conjunto de la puerta para exponer las leng etas restantes del pestillo de metal Sostenga las leng etas completamente con alicates para ret
10. 30R tipo NEMA 14 30R La secadora DEBE emplear un cable de alimentaci n La secadora DEBE emplear un cable de alimentaci n el ctrica de 3 conductores tipo NEMA 10 30 SRDT el ctrica de 4 conductores tipo NEMA 14 30 SRDT o calificado para CA m nima de 240 voltios 30 amp con 3 ST seg n se especifique calificado para CA m nima conectores de terminal horquilla con extremos doblados de 240 voltios 30 amp con 4 conectores de terminal hacia arriba o de bucle cerrado y calificados para uso horquilla con extremos doblados hacia arriba o de en secadoras de ropa Para obtener instrucciones sobre Ey rel lead ee a i i eE a aaa MIS tetrafilar consulte CONEXIONES EL CTRICAS PARA UN SISTEMA TETRAFILAR L NOTA Las secadoras fabricadas para la venta en Canad vienen con un cable de alimentaci n el ctrica tetrafilar NEMA 14 30R de f brica 28 Requisitos el ctricos de la secadora a gas CIRCUITO Circuito individual de bifurcaci n de 15 amp correctamente polarizado y con conexi n a tierra con fusible de retardo de 15 amp o con interruptor autom tico SUMINISTRO EL CTRICO corriente alterna de 2 cables con conexi n a tierra 120 voltios monof sica 60 Hz CABLE DE ALIMENTACI N EL CTRICA la secadora est equipada con un cable de alimentaci n trifilar de 120 voltios CONEXI N A TIERRA consulte Requisitos de conexi n a tierra en la secci n Instalaci n el ctrica Requerimientos del suministro de gas
11. Depending on the model you purchased a drying rack may have been included in the initial purchase of your dryer If your model did not include a drying rack or you desire another drying rack you may order one UNI VERSAL APPLI ANCE WRENCH P N 137019200 A UNIVERSAL APPLIANCE WRENCH is available to aid in dryer washer pedestal feet adjustment result in personal injury property damage or damage to the dryer TOUCH UP PAI NT PENS Classic White Touch Up Pen P N 5304468812 Classic Red Touch Up Pen P N 5304471227 Classic Blue Touch Up Pen P N 5304471229 Classic Silver Touch Up Pen P N 5304471228 Classic Black Touch Up Pen P N 5304458932 Other colors may be available Contact the source where you purchased your dryer Replacement parts If replacements parts are needed for your washer A WARNING contact the source where you purchased your washer or refer to your Use and Care Guide for more information ELECTRICAL SHOCK HAZARD Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing 24 FRIGIDAIRE nstalaci n NDICE Instrucciones importantes de seguridad 26 27 Instrucciones de instalaci n ccceeeee 36 43 Requisitos de instalaci N onnninnnionccccnno css 28 34 Inversion e la pu E csoconaoncotacoaavaaboacvnau00n00L0 44 47 Dimensiones de la secadora instalada
12. INSTALACI N Conexi n de agua modelo a vapor solamente continuaci n 5 Si es posible instalar la conexi n en Y directamente en el suministro de agua fr a enrosque el conector en Y a la tuber a de agua FR A y apri telo bien a mano Luego apri telo 2 3 de vuelta m s usando alicates L NOTA Si fuera a instalar el conector en Y directamente al suministro de agua FR A vaya directo al paso 8 6 Sino es posible instalar la conexi n en Y directamente en el suministro de agua fr a enrosque una manguera de extensi n corta en la tuber a de agua FRIA y apri tela bien a mano Luego apri tela 2 3 de vuelta m s usando alicates L NOTA Extensi n corta disponible en su ferreter a mas cercana La extensi n debe estar certificada para instalaciones de lavander a 7 Enrosque el conector en Y en la manguera de extensi n corta Luego apri telo 2 3 de vuelta m s usando alicates 8 Conecte la manguera de admisi n de agua FR A al conector en Y y apri tela a mano Luego apri tela 2 3 de vuelta m s usando alicates 9 Conecte el extremo recto de la manguera larga del kit a la otra salida del conector en Y y apri telo a mano Conecte el codo de 90 de la manguera a la admisi n de agua de lat n en la parte trasera de la secadora y apri telo a mano Apriete todas las conexiones de la manguera de admisi n de agua de la secadora 2 3 de vuelta m s usando alicates 10 Abra el
13. LLAVE UNIVERSAL PARA ELECTRODOM STICOS Pieza No 137019200 Tambi n puede pedir una LLAVE UNIVERSAL PARA ELECTRODOMESTICOS para ayudarlo a ajustar las patas de las secadoras lavadoras o pedestales MARCADORES DE PINTURA DE RETOQUE Marcador de retoque de pintura blanca Pieza Ne 5304468812 Marcador de retoque de pintura rojo Pieza N 5304471227 Marcador de retoque de pintura azul Pieza N 5304471229 Marcador de retoque de pintura plateada Pieza N2 5304471228 Marcador de retoque de pintura negra Pieza N 5304458932 Es posible que hayan otros colores disponibles P ngase en contacto con el distribuidor donde adquiri la secadora Piezas de repuesto 4 PRECAUCI N El no utilizar accesorios fabricados o aprobados por el fabricante puede ocasionar lesiones personales da os a la propiedad o da os a la secadora Si su secadora necesita piezas de repuesto A ADVERTENCIA comun quese con el sitio donde la adquiri o consulte la Gu a de uso y cuidado para obtener m s PELIGRO DE DESCARGA EL CTRICA informaci n Cuando se reparen los controles rotule todos los cables antes 48 de desconectarlos Los errores de cableado pueden producir un funcionamiento incorrecto y peligroso Verifique que el funcionamiento es correcto despu s de realizar las reparaciones
14. Turn the inner door assembly back over and locate screws removed previously Reinstall plastic plug in the 2 pan head hinge screws Remove and save the the square hole next to the hinge 2 screws and separate the hinge from inner door assembly REVERSING DOOR Reassembling the door 1 Lift the inner glass ring Rotate it 180 degrees reinstall on outer door lining up indicators LH for left hand hinge or RH for right hand hinge 2 Rest the opening of the inner door at a 90 degree angle on the supports for the hinge cutout cover Pivot the inner door down onto the outer door 3 Replace indented head screws no 1 5 removed earlier Take care not to strip out the plastic holes 4 Replace pan head screws no 6 7 removed earlier Take care not to strip out the plastic holes 5 Locate new metal strike supplied with dryer manuals Grip new strike with pliers as shown below Firmly insert the strike so it is oriented vertically Reattaching the door 1 Holding the door in both hands squarely insert the T post on the back of the hinge into the T slot on the front panel and lower it to align the mounting holes T SLOT IN T POST ON FRONT PANEL DOOR HINGE 2 While supporting the door install the upper pan head screw first and then the lower one L NOTE Correctly installed
15. antes de usar este secadora Identificaci n de los s mbolos palabras y avisos de seguridad Las indicaciones de seguridad incluidas en este manual aparecen precedidas de un aviso titulado ADVERTENCIA o PRECAUCI N de acuerdo con el nivel de riesgo Definiciones A Este es el s mbolo de alerta de seguridad Se usa para alertar sobre peligros potenciales de lesiones personales Obedezca todos los mensajes de seguridad que tengan este s mbolo para evitar posibles lesiones personales o la muerte 4 PELIGRO PELIGRO indica una situaci n de peligro inminente que si no se evita podr a causar lesiones graves o la muerte ADVERTENCIA ADVERTENCIA indica una situaci n potencialmente peligrosa que si no se evita podr a causar lesiones personales graves o la muerte 4 PRECAUCI N PRECAUCI N indica una situaci n potencialmente peligrosa que si no se evita podr a causar lesiones personales leves o moderadas ma IMPORTANTE IMPORTANTE indica informaci n de instalaci n funcionamiento o mantenimiento que es importante pero que no est relacionada con la seguridad MZ Lista de verificaci n de instalaci n Ventilaci n de escape U De flujo libre y sin acumulaci n de pelusa A Conductos r gidos o semir gidos de 4 102 mm de distancias y giros m nimos A SIN materiales de ventilaci n de aluminio o de pl stico QA El sistema de evacuaci n debe ventilar al exterior y contar con una capu
16. cobre o viceversa La reacci n qu mica que tiene lugar entre el cobre y el aluminio puede causar cortocircuitos el ctricos El recept culo y el cableado correcto consiste en un cable de alimentaci n con alambres de cobre con un recept culo de cables de cobre L NOTA Las secadoras que funcionan con 208 voltios de corriente el ctrica tendr n tiempos de secado m s prolongados que las que funcionan con 240 voltios de corriente el ctrica Requisitos de conexi n a tierra secadora el ctrica Estados Unidos 4 ADVERTENCIA PELIGRO DE DESCARGA EL CTRICA Una conexi n incorrecta del conductor de conexi n a tierra del equipo puede provocar un peligro de descarga el ctrica Si no est seguro de haber realizado correctamente la conexi n a tierra del artefacto consulte a un electricista autorizado Para una secadora conectada a tierra 1 La secadora DEBE tener conexi n a tierra En el caso de que la secadora no funcione correctamente o se descomponga la conexi n a tierra reduce el riesgo de descarga el ctrica porque ofrece una trayectoria de menor resistencia para la corriente el ctrica 2 Despu s de comprar e instalar un cable de alimentaci n trifilar o tetrafilar con un conductor de conexi n a tierra el enchufe DEBE estar conectado 36 a un recept culo adecuado con cable de cobre correctamente instalado y con conexi n a tierra de acuerdo con todos los c digos y las ordenanzas locales Ante cualqu
17. e S lo se debe utilizar una red de conductos de metal r gido e Si la ventilaci n se efect a en forma vertical a trav s del techo es posible que el sistema de escape se vea expuesto a r fagas descendentes que restringir n la ventilaci n e Si el sistema de escape se extiende a trav s de un rea que no est aislada puede producirse condensaci n y una acumulaci n m s r pida de pelusa e La compresi n o los pliegues del sistema de escape aumentar n la restricci n de la ventilaci n e Se debe inspeccionar y limpiar el sistema de escape cada 18 meses como m nimo cuando se le da un uso normal Cuanto m s utilice la secadora m s a menudo deber comprobar que el sistema de escape y la capucha de ventilaci n funcionan correctamente 32 Direcci n del escape El escape direccional se puede lograr mediante la instalaci n de un codo de ventilaci n de giro r pido de 90 directamente en la salida de la secadora Los codos de ventilaci n de la secadora se encuentran disponibles a trav s de su distribuidor de repuestos o ferreter a local Consulte tambi n los REQUISITOS DE DESPEJE en la siguiente p gina L NOTA Utilice un codo de giro r pido de 90 para cumplir con la profundidad m nima de instalaci n de la secadora independiente e La ventilaci n derecho hacia atr s permite la instala ci n de la secadora a 0 0 cm de la pared e La ventilaci n hacia la derecha con un codo de 90 pe
18. garaje debe estar a una altura m nima de 45 7 cm 18 pulgadas por encima del suelo De lo contrario podr a producirse una explosi n un incendio quemaduras o incluso la muerte REQUISITOS DE INSTALACI N sistema de evacuaci n DEBE terminar fuera del espacio cerrado y el extremo debe quedar sujetado firmemente a la estructura de la casa rodante Para obtener informaci n sobre otros requisitos importantes del sistema de escape consulte las secciones anteriores de esta gu a Cuando se instale una secadora a gas en una casa rodante se debe dejar espacio en el exterior para la salida de aire Este espacio debe ser por lo menos el doble del rea de la salida de escape de la secadora El t cnico de instalaci n DEBE anclar esta secadora 1 o secadora sobre pedestal 2 al piso usando un kit de instalaci n para casas rodantes pieza n mero 137067200 IMPORTANTE NO INSTALE LA SECADORA 1 2 En una zona expuesta a la humedad o a las condiciones clim ticas externas En un rea en la que est en contacto con cortinas telas colgantes o cualquier otra cosa que pueda obstruir el flujo de aire de ventilaci n y combusti n Sobre una alfombra El piso DEBE ser firme con una pendiente m xima de 2 54 cm 1 pulgada 33 REQUISITOS DE INSTALACI N Requisitos de despeje continuaci n Instalaci n en un Nicho o Armario PARTE PARTE PARTE 1 Una secadora instalada en un dormitorio ba o nicho o armario DEBE
19. generadores a gas solares e licos ni de ninguna otra clase que no sean los empleados por su empresa de electricidad local Requisitos el ctricos de la secadora el ctrica CIRCUITO circuito independiente individual de 30 amp con fusibles de acci n retardada o disyuntores Use circuitos con fusibles separados para la lavadora y la secadora NO haga funcionar una lavadora y una secadora en el mismo circuito SUMINISTRO EL CTRICO trifilar o tetrafilar 240 V 1 fase 60 Hz corriente alterna m IMPORTANTE A menos que haya sido fabricada para la venta en Canad esta secadora est conectada a tierra internamente a trav s de un enlace a un conductor neutro La conexi n a tierra a trav s del neutro est prohibida para 1 instalaciones de circuitos de bifurcaci n nuevos 2 casas rodantes 3 veh culos recreativos y 4 reas cuyas leyes locales no permiten la puesta a tierra a trav s del neutro RECEPT CULO DEL TOMACORRIENTE recept culo NEMA 10 30 R o NEMA 14 30 R que debe estar ubicado en un lugar al que pueda acceder el cable de alimentaci n el ctrica cuando la secadora est instalada CONEXI N A TIERRA consulte Requisitos de conexi n a tierra en la secci n Instalaci n el ctrica CABLE DE ALIMENTACI N EL CTRICA TRIFILAR no CABLE DE ALIMENTACI N EL CTRICA TETRAFILAR no incluido incluido Recept culo trifilar Recept culo tetrafilar tipo NEMA 10
20. grifo y verifique que no haya fugas en ninguna de las conexiones 40 CONEXI N DIRECTA O CON EXTENSION ADMISION DE AGUA EN LA SECADORA MANGUERA DE SUMINISTRO DE AGUA FRIA A LA LAVADORA Extensi n de manguera no incluida con la secadora INSTRUCCIONES DE INSTALACI N Conexi n el ctrica fuera de Canad trifilar Recept culo trifilar tipo NEMA 10 30R 4 ADVERTENCIA PELIGRO DE DESCARGA EL CTRICA El no desconectar el suministro el ctrico antes de realizar cualquier reparaci n puede ocasionar lesiones personales o incluso la muerte 1 Desconecte el suministro el ctrico del tomacorriente 2 Extraiga el tornillo que sujeta la cubierta de acceso del bloque terminal que se encuentra en la esquina inferior de la parte trasera de la secadora 3 Instale un dispositivo de liberaci n de tensi n aprobado por U L de acuerdo con las instrucciones relativas al cable de alimentaci n dispositivo de liberaci n de tensi n del fabricante en el orificio de entrada del cable de alimentaci n debajo del panel de acceso En este momento el dispositivo de liberaci n de tensi n debe estar holgadamente en su lugar 4 Pase un cable de alimentaci n aprobado por U L DESENCHUFADO de 30 amp tipo NEMA 10 30 SRDT a trav s del dispositivo de liberaci n de tensi n 5 Conecte el conductor neutro cable del centro del cable de alimentaci n al terminal PLATEADO del cen
21. hinge screws will press hinge flush to front panel Any gap between hinge and front panel will cause misalignment of strike to latch REVERSING DOOR 3 Close the door and test operation of hinge strike and latch 23 ACCESSORIES MATCHI NG STORAGE PEDESTAL Classic White Pedestal P N CFPWD15W A CAUTION Classic Blue Pedestal P N CFPWD15N Classic Red Pedestal P N CFPWD15R Failure to use accessories manufactured by Classic Silver Pedestal P N CFPWD15A or approved by the manufacturer could Classic Black Pedestal P N CFPWD15B A storage pedestal accessory specifically designed for this dryer may be used to elevate the dryer for ease of use This pedestal will add about 15 38 cm to the height of your unit for a total height of 51 25 130 cm Other colors may be available Contact the source where you purchased your dryer DRYER STACKING KIT P N STACKIT4X Depending on the model you purchased a kit for stacking this dryer on top of O washer may have been included in the initial purchase of your dryer If your model did not include a stacking kit or you desire another stacking kit you may order one LP CONVERSION KIT P N PCK4200 Gas dryers intended for use in a location supplied with LP must use a conversion kit prior to installation MOBILE HOME I NSTALLATI ON KIT P N 137067200 Installation in a mobile home requires the use of a MOBILE HOME INSTALLATION KIT DRYING RACK P N 137067300
22. la rodea 4 ADVERTENCIA PELIGRO DE INCENDIO e No permita que materiales combustibles por ejemplo ropa tapicer a cortinas papel entren en contacto con el sistema de escape La secadora NO DEBE tener escape a una chimenea una pared un techo ni ning n espacio cerrado de un edificio que pueda acumular pelusa y constituir un peligro de incendio e No bloquee los extremos de escape del sistema de ventilaci n ni utilice tornillos remaches ni otros sujetadores que se extiendan hacia la parte interna del conducto para ensamblarlo Es posible que la pelusa quede atrapada en el filtro los tornillos o los remaches lo que puede obstruir la red de conductos y constituir un peligro de incendio as como tambi n aumentar los tiempos de secado En la salida del conducto al exterior utilice una capucha de ventilaci n aprobada y selle todas las uniones con cinta de papel aluminio Todos los accesorios macho para tubos DEBEN instalarse teniendo en cuenta el flujo de aire 4 ADVERTENCIA PELIGRO DE INCENDIO Si se excede la longitud del tubo del conducto o el n mero de codos permitidos en las tablas de LONGITUD MAXIMA se pueden acumular pelusas en el sistema de escape La obstrucci n del sistema podr a constituir un peligro de incendio as como aumentar los tiempos de secado LONGITUD M XIMA Conducto de metal r gido de 102 mm 4 pulgadas TIPO DE CAPUCHA DE VENTILACI N aberturas de 2 5 ventilaci n 6
23. tener ventilaci n al exterior 0 cm 0 0 cm 0 0 cm 0 2 No se debe instalar ning n otro artefacto de combusti n en el mismo armario que la secadora a Sous locm o Ocm 0 0cm 0 n d gas le comptoir 3 La secadora necesita espacio a Su alrededor para Placard 0 cm 0 0 cm 0 0 cm 0 2 54 cm 17 que la ventilaci n sea adecuada NO instale la secadora en un armario con puerta maciza La ventilaci n derecho hacia atr s permite la instalaci n 4 Ventilaci n requerida en la puerta del armario Se de la secadora a 0 0 cm de la pared necesita un m nimo de 774 2 cm 120 pulgadas de abertura dividido en partes iguales en la parte superior e inferior de la puerta Las aberturas de ventilaci n deben estar ubicadas a 7 6 cm 3 pulgadas de la parte superior e inferior de la puerta Es necesario que las aberturas de aire no est n obstruidas al instalar una puerta Se acepta una puerta que tenga aberturas de ventilaci n distribuidas uniformemente en toda la superficie 60 sq in 387 1cm2 y 2 54cm 60 sq in 887 1cm2 te f puerta del armario 34 DI MENSI ONES DE LA SECADORA I NSTALADA 51 4 131cm para destapar abra la puerta t P gt 30 3 77cm al frente de la puerta cerrada tuber a de suministro de gas en la parte trasera de la
24. tico fusibles 5 Consulte la Gu a de uso y cuidado que se proporciona con la secadora Dicha gu a contiene informaci n til y valiosa que le ahorrar tiempo y dinero 6 Sitiene alguna pregunta durante el funcionamiento inicial repase la Lista de control para evitar el servicio t cnico de su Gu a de uso y cuidado antes de llamar al servicio t cnico 7 Guarde estas instrucciones cerca de la secadora para referencia futura L NOTA Dentro de la consola de la secadora encontrar una hoja de informaci n t cnica y un diagrama de cableado Tomacorriente con puesta a tierra No corte retire ni deshabilite la clavija de conexi n a tierra bajo ninguna circunstancia Cord n el ctrico de 3 clavijas con puesta a tierra EE 43 INVERSI N DE LA PUERTA C mo extraer la puerta 1 Proteja las superficies de trabajo planas como la 4 Coloque cuidadosamente la puerta de la secadora parte superior de la secadora o el piso cerca de sobre una superficie de trabajo plana y protegida sta utilizando un pa o o toalla suave con la superficie exterior hacia abajo 2 Abra la puerta de la secadora y retire los dos 5 Ubique los 5 tornillos de cabeza corrugada no tornillos de la bisagra Retire el tornillo inferior 1 5 en las muescas circulares peque as en las primero y luego el tornillo superior posiciones relativas al reloj de las 11 1 4 6 y 8 de
25. toque ning n interruptor el ctrico no utilice ning n tel fono PELIGRO DE EXCESO DE PESO em venies o a Para evitar lesiones en la espalda u otro tipo e Despeje la habitaci n el edificio o el rea de todos los ocupantes de lesiones procure levantar o mover la e Llame inmediatamente a su proveedor de gas desde el tel fono electrodom stico con la ayuda de m s de una de un vecino Siga las instrucciones del proveedor de gas persona e Si no puede ponerse en contacto con el proveedor de gas llame y alos bomberos Conserve estas instruccio nes para referencia futura Requisitos de preinstalaci n Herramientas y materiales necesarios para la instalaci n e Pinzas ajustables e Nivel de carpintero e V lvula de cierre de l nea de gas e Destornilladores Philips con punta e Capucha de ventilaci n externa secadora a gas derecha y cuadrada e Conducto de escape de metal r gido o Adaptadores NPI de uni n acampa e Llave ajustable semir gido de 4 pulgadas 102 mm nada x2 y l nea flexible de sumi e Llave para tubos de suministro de Kit de cables de alimentaci n trifilar nistro de gas secadora a gas de gas o tetrafilar de 240 voltios secadora 7a 15 2 cm o e Cinta aislante resistente al gas LP el ctrica Cinta de papel aluminio no cinta para suministro de gas natural o LP Abrazadera de 4 10 2 cm adhesiva aislante 26 INSTRUCCIONES IMPORTANTES DE SEGURIDAD 4 ADVERTENCIA Lea todas las instrucciones
26. unidad de gas secadora independiente sobre el piso l nea del piso secadora colocada sobre pedestal opcional l nea del piso Para obtener estas dimensiones m nimas de profundidad la secadora debe ser ventilada derecho hacia atr s Si se usa un codo de giro r pido de 90 hacia la derecha o hacia abajo en la secadora independiente se agregan aproximadamente 0 75 2 cm a la profundidad de instalaci n Si se orienta el escape de la secadora independiente o sobre un pedestal hacia arriba la profundidad de instalaci n aumentar aproximadamente en 4 10 2 cm Si se orienta el escape de la secadora independiente o sobre un pedestal hacia la izquierda la profundidad de instalaci n aumentar aproximadamente en 3 75 9 5 cm Si se orienta el escape de la secadora sobre un pedestal hacia abajo la profundidad de instalaci n aumentar aproximadamente en 2 25 5 7 cm 3 75 9 5cm 51 4 131cm _ gt para destapar abra la puerta lt g 30 3 77cm gt al frente de la puerta cerrada 71 5 182cm conexi n del suministro de agua en la parte trasera de la lavadora tuber a de suministro de gas en la parte trasera de la unidad de gas 37 94cm e 27 0 68 5cm suministro el ctrico en la parte trasera de la unidad altura de la l nea central para ventilaci n trasera
27. 35 cm o aens ADVERTENCIA PELIGRO DE INCENDIO e No utilice material de ventilaci n flexible de pl stico o aluminio e Si va a instalar conductos de ventilaci n semirrigidos no exceda una longitud de 8 pies 2 4 m J q o 0 a o oO Q e Q ie wn o oO w o o 3l REQUISITOS DE INSTALACI N Requisitos del sistema de escape continuaci n Instale los accesorios macho en la direcci n correcta CORRECTO INCORRECTO En instalaciones en las que el sistema de escape no se describa en las tablas se debe utilizar el siguiente m todo para determinar si dicho sistema es aceptable 1 Conecte un man metro inclinado o digital entre la secadora y el punto donde el tubo de escape se conecta con la secadora 2 Coloque el temporizador y la temperatura de la secadora en la opci n Air fluff cool down Esponjado con aire enfriamiento y ponga en marcha la secadora 3 Lea la medici n del man metro 4 La contrapresi n del sistema NO DEBE ser mayor que 2 5 cm 1 pulgada de columna de agua Si la contrapresi n del sistema es menor que 2 5 cm 1 pulgada de columna de agua el sistema es aceptable Si la lectura del man metro es mayor que 2 5 cm 1 pulgada de columna de agua el sistema es demasiado restrictivo y la instalaci n es inaceptable Si bien la orientaci n vertical del sistema de escape es aceptable ciertas circunstancias atenuantes podr an afectar el funcionamiento de la secadora
28. LATION INSTRUCTIONS Electrical connection non Canada 4 wire cord A 4 wire receptacle Ea NEMA type 14 30R Neutral WHITE wire 30 AMP Ground NEMA 14 30 GREEN wire 4 WARNING o ELECTRI CAL SHOCK HAZARD Failure to disconnect power source before servicing could result in personal injury or even death ES de 1 Turn off power supply to outlet o u7 S7 cie 2 Remove the screw securing the terminal block deis access cover in the lower corner on the back of the linea dryer BRASS terminal 3 Install a UL approved strain relief according to the U aia power cord strain relief manufacturer s instructions O SILVER terminal in the power cord entry hole below the access E panel At this time the strain relief should be anal BRASS terminal 4 Thread an UNPLUGGED UL approved 30 amp Internal ground loosely in place power cord NEMA 14 30 type ST or SRDT through GREEN screw the strain relief 9 Install 5 Disconnect the internal BLACK dryer harness eri o Terminal screw recovery slot ground wire from the GREEN ground screw next to the terminal block 6 Attach the ground GREEN power cord wire to the cabinet with the ground GREEN screw Tighten the screw securely L NOTE 7 Move the internal dryer harness ground BLACK If a terminal screw falls during cord installation it can wire to the terminal blo
29. PORTANTE NO conecte la secadora al servicio de gas LP sin convertir la v lvula de gas El kit de conversi n a gas LP debe ser instalado por un t cnico calificado 2 Conecte un tubo aprobado o uno semi r gido de 1 27 cm 1 2 pulgada de di metro interior desde la l nea de suministro de gas al tubo de 0 96 cm 3 8 pulgada ubicado en la parte trasera de la secadora Utilice un reductor de 1 27 cm a 0 96 cm 1 2 pulgada a 3 8 pulgada para realizar la conexi n Aplique un sellador para roscas que sea resistente a la acci n corrosiva de los gases licuados en todas las conexiones de los tubos FLUJO DE GAS V lvula Conector Conector de cierre le doble manual a mo Y al E Tubo de admisi n en la parte posterior de la secadora Todas las conexiones deben estar ajustadas con llave Conector Conector Abierto flexible 3 IMPORTANTE La l nea de suministro de gas debe estar equipada con una v lvula de cierre manual aprobada Esta v lvula debe estar ubicada en la misma habitaci n que la secadora en una ubicaci n que permita la facilidad de apertura y cierre No bloquee el acceso a la v lvula de cierre de gas 38 3 Abra la v lvula de cierre de la linea de suministro de gas para que el gas fluya a trav s de la tuber a Espere unos minutos a que el gas fluya a trav s de la l nea de suministro de gas V lvula de cierre posici n abierta 4 Utilice un man metro para ver
30. ain relief should be loosely in place 4 Thread an UNPLUGGED UL approved 30 amp power cord NEMA 10 30 type SRDT through the strain relief 5 Attach the power cord neutral center wire conductor to the SILVER colored center terminal on the terminal block Tighten the screw securely 6 Attach the remaining two power cord outer conductors to the outer BRASS colored terminals on the terminal block Tighten both screws securely 4 WARNING ELECTRI CAL SHOCK HAZARD Do not make a sharp bend or crimp wiring conductor at connections 7 Follow manufacturer s guidelines for firmly securing the strain relief and power cord 8 Reinstall the terminal block cover mJ IMPORTANT If moving dryer from a 4 wire system and installing it in a 3 wire system move the internal ground from the center terminal back to the GREEN screw next to the terminal block NE 30 AMP LL NEMA 10 30 Neutral I center wire screw Line 2 BRASS terminal Neutral SILVER terminal N ZNL T a N Line 1 BRASS terminal Internal ground GREEN screw Install UL approved strain relief here Terminal screw recovery slot amp NOTE If a terminal screw falls during cord installation it can be retrieved in the terminal screw recovery slot below the access panel DO NOT remove internal ground in a 3 wire system Neutral terminal 17 INSTAL
31. and ordinances and the latest edition of the National Fuel Gas Code ANSI Z223 1 or in Canada CAN ACG B149 1 2000 An individual manual shut off valve must be installed within 6 ft 1 83 m of the dryer in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 e The dryer is designed under ANSI Z 21 5 1 or ANSI UL 2158 CAN CSA C22 2 No 112 latest editions for HOME USE only This dryer is not recommended for commercial applications such as restaurants beauty salons etc e Do not install a clothes dryer with flexible plastic venting material Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer airflow and increase the risk of fire e The instructions in this manual and all other literature included with this dryer are not meant to cover every pos sible condition and situation that may occur Good safe practice and caution MUST be applied when installing operating and maintaining any appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance A CAUTION Do not touch any electrical switch do not use any phone in EXCESSIVE WEI GHT HAZARD your building o To avoid back or other injury have more than e Clear the room building or area of all occupants one person move or lift the appliance e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions Save these instructions for e If you cannot reach y
32. ath of least resistance for electrical current Since your dryer is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances If in doubt call a licensed electrician DO NOT modify the plug provided with this appliance If it will not fit the outlet have a proper outlet installed by a qualified electrician Grounding requirements Gas dryer USA and Canada 1 The dryer is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle 2 The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances f in doubt call a licensed electrician 3 DO NOT modify the plug provided with this appliance If it will not fit the outlet have a proper outlet installed by a qualified electrician Grounding type wall receptacle Do not under any circumstances cut remove or bypass the grounding prong Y Power cord with 3 prong grounded plug 13 INSTALLATION INSTRUCTIONS Gas connection 1 Remove the shipping cap from gas pipe at the rear of the dryer m IMPORTANT DO NOT connect the dryer to L P gas service without converting the gas val
33. ble certain extenuating circumstances could affect the performance of the dryer e Only the rigid metal duct work should be used e Venting vertically through a roof may expose the exhaust system to down drafts causing an increase in vent restriction e Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint e Compression or crimping of the exhaust system will cause an increase in vent restriction e The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation Exhaust direction Directional exhausting can be accomplished by installing a quick turn 90 dryer vent elbow directly to exhaust outlet of dryer Dryer vent elbows are available through your local parts distributor or hardware store See also CLEARANCE REQUIREMENTS on the next page L NOTE Use of 90 quick turn elbow required to meet minimum installation depth of free standing dryer e Straight back venting allows for 0 0 cm installation e Venting right with 90 elbow allows for 0 75 2 cm installation e Venting downward with 90 elbow allows for 0 75 2 cm installation e Venting left with short straight adapter and 90 elbow allows for 3 75 9 5 cm installation e Venting upward with short straight adapter and 90 elbow allows for 4
34. box before plugging the power cord into an outlet 3 Plug the power cord into a grounded outlet 4 Turn on the power at the circuit breaker fuse box 5 Read the Use amp Care Guide provided with the dryer It contains valuable and helpful information that will save you time and money 6 If you have any questions during initial operation please review the Avoid Service Checklist in your Use amp Care Guide before calling for service 7 Place these instructions in a location near the dryer for future reference L NOTE A wiring diagram and technical data sheet are located inside the dryer console Grounding type wall receptacle Do not under any circumstances cut remove or bypass the grounding prong Power cord with 3 prong grounded plug INSTALLATION INSTRUCTIONS m 19 REVERSING DOOR Removing the door 1 Protect flat work surface such as top of dryer or floor near dryer with a soft cloth or towel 2 Open dryer door and remove the two hinge screws Remove lower screw first then upper screw 3 Supporting door with both hands squarely lift door and hinge upward approximately 3 8 10 mm so T post on back of hinge can slide out through T slot on front panel T SLOT IN FRONT PANEL T POST ON DOOR HINGE
35. cha de ventilaci n aprobada Nivelaci n A La secadora est nivelada de lado a lado y de adelante hacia atr s QA Elsecadora descansa firmemente sobre sus cuatro esquinas Suministro de gas secadora a gas O V lvula de cierre manual instalada en la tuber a de suministro Todas las conexiones selladas con un sellante aprobado y bien apretadas con una llave Kit de conversi n para el sistema de gas LP Suministro de gas abierto No hay escapes en ninguna conexi n verifique con agua jabonosa NUNCA con una llama Suministro el ctrico de 240V secadora el ctrica A Cord n de servicio el ctrico 10 30R o 10 40R aprobado por la NEMA con todos los tornillos bien apretados en el tablero de terminales a Dispositivo de liberaci n de tensi n aprobado A Tapa de acceso a los terminales instalada antes del primer uso Inversion de la puerta a Siga las instrucciones detalladas en esta gu a QA Pruebe la bisagra y el gancho para asegurarse de que funcionen Suministro el ctrico A El suministro el ctrico del hogar est activado UA La secadora est enchufada Inspecci n final Lea bien las instrucciones de instalaci n y la gu a de uso y cuidado QA La puerta se cierra y el tambor gira cuando se inicia el ciclo a Tarjeta de registro enviada QO QO QO QO 21 REQUISITOS DE INSTALACI N L NOTA Debido a posibles variaciones en el voltaje no se recomienda utilizar esta secadora con electricidad generada a partir de
36. ck and attach it along with be retrieved in the terminal screw recovery slot below the neutral WHITE power cord wire conductor the access panel to the center SILVER colored terminal on the a TE j Move internal ground WHITE eutra terminal block Tighten the screw securely wire to neutral SILVER il 8 Attach the RED and BLACK power cord conductors trina for to system Sy to the outer BRASS colored terminals on the terminal block Tighten both screws securely WHITE neutral wire 4 WARNING GREEN ELECTRI CAL SHOCK HAZARD ground screw Do not make a sharp bend or crimp wiring conductor at connections 9 Follow manufacturer s guidelines for firmly securing the strain relief and power cord 10 Reinstall the terminal block cover BLACK or RED ground wire power wire RED power wire 18 General installation 1 Connect the exhaust duct to the outside exhaust system see pages 6 through 8 Use of a 4 102 mm clamp item A is recommended to connect the dryer to the exhaust vent system Use metal foil tape to seal all other joints 2 Carefully slide the dryer to its final position Adjust one or more of the legs until the dryer is resting solidly on all four legs Place a level on top of the dryer The dryer MUST be level and resting solidly on all four legs Rock alternating corners to check for stability Remove and discard door tape m IMPORTANT Be sure the power is off at a circuit breaker fuse
37. conectado a un tomacorriente correctamente instalado y con conexi n a tierra de acuerdo con todos los c digos y las ordenanzas locales Ante cualquier duda comun quese con un electricista autorizado NO realice modificaciones al enchufe que se proporciona con este artefacto Si no calza en el tomacorrientes p dale a un electricista calificado que instale un tomacorrientes adecuado de menor resistencia para la corriente el ctrica Debido a que la secadora est equipada con un cable de alimentaci n el ctrica que cuenta con un conductor de conexi n a tierra el enchufe debe estar conectado a un tomacorriente correctamente instalado y con conexi n a tierra de acuerdo con todos los c digos y las ordenanzas locales Ante cualquier duda comun quese con un electricista autorizado NO realice modificaciones al enchufe que se proporciona con este artefacto Si no calza en el tomacorrientes p dale a un electricista calificado que instale un tomacorrientes adecuado Requisitos de conexi n a tierra secadora a gas Estados Unidos y Canad 1 La secadora est equipada con un enchufe de tres Tomacorriente con puesta a tierra No corte retire ni deshabilite la clavija de conexi n a tierra bajo ninguna circunstancia SS Cord n el ctrico de 3 clavijas con puesta a tierra 37 INSTRUCCIONES DE INSTALACI N Conexi n de gas 1 Quite el tap n del tubo de gas en la parte trasera de la secadora mJ IM
38. e NEMA type 10 30R NEMA type 14 30R The dryer MUST employ a 3 conductor power The dryer MUST employ a 4 conductor power supply supply cord NEMA 10 30 type SRDT rated at 240 cord NEMA 14 30 type SRDT or ST as required rated volt AC minimum 30 amp with 3 open end spade at 240 volt AC minimum 30 amp with 4 open end lug connectors with upturned ends or closed spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes loop connectors and marked for use with clothes dryers For 3 wire cord connection instructions see dryers For 4 wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 3 WIRE SYSTEM ELECTRICAL CONNECTIONS FOR A 4 WIRE SYSTEM amp NOTE Dryers manufactured for sale in Canada have factory installed 4 wire power supply cord NEMA 14 30R Electrical requirements for gas dryer CIRCUIT Individual properly polarized and grounded 15 amp branch circuit fused with 15 amp time delay fuse or circuit breaker POWER SUPPLY 2 wire with ground 120 volt single phase 60 Hz Alternating Current POWER SUPPLY CORD The dryer is equipped with a 120 volt 3 wire power cord GROUNDING CONNECTION See Grounding requirements in Electrical Installation section Gas supply requirements 4h WARNING EXPLOSION HAZARD Uncoated copper tubing will corrode when subjected to natural gas causing gas leaks Use ONLY black iron stainless steel or plastic coated brass piping
39. ed 4h WARNING FIRE HAZARD A clothes dryer must be exhausted outdoors Do not exhaust dryer into a chimney a wall a ceiling an attic a crawl space or any concealed space of a building A clothes dryer produces combustible lint If the dryer is not exhausted outdoors some fine lint will be expelled into the laundry area An accumulation of lint in any area of the home can create a health and fire hazard The dryer must be connected to an exhaust outdoors Regularly inspect the outdoor exhaust opening and remove any accumulation of lint around the outdoor exhaust opening and in the surrounding area 4 WARNING FIRE HAZARD Do not allow combustible materials for example clothing draperies curtains paper to come in contact with exhaust system The dryer MUST NOT be exhausted into a chimney a wall a ceiling or any concealed space of a building which can accumulate lint resulting in a fire hazard Do not screen the exhaust ends of the vent system or use any screws rivets or other fasteners that extend into the duct to assemble the exhaust system Lint can become caught in the screen on the screws or rivets clogging the duct work and creating a fire hazard as well as increasing drying times Use an approved vent hood to terminate the duct outdoors and seal all joints with metal foil duct tape All male duct pipe fittings MUST be installed downstream with the flow of air WARNING FIRE HAZARD Exceeding the l
40. ength of duct pipe or number of elbows allowed in the MAXIMUM LENGTH charts can cause an accumulation of lint in the exhaust system Plugging the system could create a fire hazard as well as increase drying times MAXIMUM LENGTH of 4 102mm Rigid Metal Duct VENT HOOD TYPE 206 JO JSQUUNN gt Ls 2 5 102mm louvered 6 35cm rss ataron suan 4h WARNING FI RE HAZARD Do not install flexible plastic or flexible foil venting material If installing semi rigid venting do not exceed 8 ft 2 4 m duct length INSTALLATION REQUIREMENTS Exhaust system requirements continued Install male fittings in correct direction CORRECT INCORRECT In installations where the exhaust system is not described in the charts the following method must be used to determine if the exhaust system is acceptable 1 Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer 2 Set the dryer timer and temperature to air fluff cool down and start the dryer 3 Read the measurement on the manometer 4 The system back pressure MUST NOT be higher than 0 75 inches of water column If the system back pressure is less than 0 75 inches of water column the system is acceptable If the manometer reading is higher than 075 inches of water column the system is too restrictive and the installation is unacceptable Although vertical orientation of the exhaust system is accepta
41. for gas supply 1 Installation MUST conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 latest edition 2 The gas supply line should be 1 2 inch 1 27 cm pipe 3 If codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass INSTALLATION REQUIREMENTS Grounding type wall receptacle Do not under any circumstances cut remove or bypass the 4 Power cord with 3 prong grounded plug The gas supply line MUST have an individual shutoff valve installed in accordance with the B149 1 Natural Gas and Propane Installation Code A 1 8 inch 0 32 cm N P T plugged tapping accessible for test gauge connection MUST be installed immediately upstream of the gas supply connection to the dryer The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1 2 psig 3 45 kPa The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa Connections for the gas supply must comply with the Standard for Connectors for Gas Appliances ANSI Z21 24 INSTALLATION REQUIREMENTS Exhaust system requirements Use only 4 inch 102 mm diameter rigid or flex
42. grounding e Do not use an extension cord with this dryer Some extension cords are not designed to withstand the amounts of electrical current this dryer utilizes and can melt creating electrical shock and or fire hazard Locate the dryer within reach of the receptacle for the length power cord to be purchased allowing some slack in the cord Refer to the pre installation requirements in this manual for the proper power cord to be purchased 4h WARNING ELECTRI CAL SHOCK HAZARD e A U L approved strain relief must be installed onto power cord If the strain relief is not attached the cord can be pulled out of the dryer and can be cut by any movement of the cord resulting in electrical shock e Do not use an aluminum wired receptacle with a copper wired power cord and plug or vice versa A chemical reaction occurs between copper and aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle L NOTE Dryers operating on 208 volt power supply will have longer drying times than dryers operating on 240 volt power supply Grounding requirements Electric dryer USA 4 WARNING ELECTRI CAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded For a grounded cord connected dryer 1 The dr
43. ible metal duct and approved vent hood which has a swing out damper s that open when the dryer is in operation When the dryer stops the dampers automatically close to prevent drafts and the entrance of insects and rodents To avoid restricting the outlet maintain a minimum of 12 inches 30 5 cm clearance between the vent hood and the ground or any other obstruction 4h WARNING FIRE HAZARD Failure to follow these instructions can create excessive drying times and fire hazards Incorrect The following are specific requirements for proper and safe operation of your dryer 4 WARNING FIRE HAZARD Do not install a clothes dryer with flexible plastic or metal foil venting materials Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer airflow and increase the risk of fire Incorrect Correct If your present system is made up of plastic duct or metal foil duct replace it with a rigid or semi rigid metal duct Also ensure the present duct is free of any lint prior to installing dryer duct INSTALLATION REQUIREMENTS Exhaust system requirements continu
44. ier duda comun quese con un electricista autorizado 3 NO realice modificaciones al enchufe que se proporciona con este artefacto Si no calza en el tomacorrientes p dale a un electricista calificado que instale un tomacorrientes adecuado Para una secadora conectada de forma permanente 1 La secadora DEBE estar conectada a un sistema de cableado permanente de metal conectado a tierra o bien se debe colocar un conductor de conexi n a tierra con los conductores del circuito y debe estar conectado al terminal de conexi n a tierra del equipo o al cable a tierra del artefacto INSTRUCCIONES DE INSTALACI N Requisitos de conexi n a tierra secadora el ctrica Canad A ADVERTENCIA PELIGRO DE DESCARGA EL CTRICA Una conexi n incorrecta del conductor de conexi n a tierra del equipo puede provocar un peligro de descarga el ctrica Si no est seguro de haber realizado correctamente la conexi n a tierra del artefacto consulte a un electricista autorizado Para una secadora conectada a tierra 1 La secadora DEBE tener conexi n a tierra En el caso de que la secadora no funcione correctamente o se descomponga la conexi n a tierra reduce el riesgo de descarga el ctrica porque ofrece una trayectoria patas conexi n a tierra para evitar el peligro de electrocuci n y debe estar conectada directamente a un recept culo de enchufe de tres patas que cuente con una conexi n a tierra adecuada El enchufe debe estar
45. ificar que no haya fugas en el suministro de gas Si no cuenta con un man metro pruebe todas las conexiones aplicando agua jabonosa en estas ADVERTENCIA PELIGRO DE EXPLOSI N NUNCA compruebe si hay fugas de gas con una llama abierta INSTRUCCIONES DE INSTALACI N Conexi n de agua modelo al vapor solamente REQUISITOS DE LA ENTRADA DE AGUA Los grifos de agua fr a DEBEN instalarse a una distancia no mayor de 107 cm 42 pulgadas de la entrada de agua de secadora Los grifos DEBEN estar a 1 9 cm 3 4 pulgadas con roscas para la conexi n de la manguera de lavado La presi n de agua DEBE ser de 30 a 120 psi El departamento hidr ulico puede asesorarlo con respecto a la presi n de agua con la que usted cuenta 1 Cierre el suministro de agua FR A a la lavadora 2 Retire la manguera de admisi n de agua FR A del suministro e inspeccione la arandela de goma Reemplace la arandela si est rota o desgastada LAS ARANDELAS DE GOMA DEBEN ESTAR PRESENTES Y SIN DANO MANGUERA DE ADMISI N DE AGUA FRIA A LA LAVADORA 3 Abra moment neamente el suministro de agua FR A y deje correr el agua en un balde o recipiente para limpiar cualquier contaminante que est presente en la tuber a 4 Retire el kit de manguera del tambor de la secadora e inspeccione los accesorios de la manguera para asegurarse de que las arandelas de goma est n en su lugar ARANDELAS DE GOMA DEBEN ESTAR PRESENTES 39 INSTRUCCIONES DE
46. inal que se encuentra debajo del panel de acceso Mueva el cable de conexi n Terminal interna a tierra BLANCO al neutro terminal del neutro PLATEADO para los sistemas tetrafilares Tornillo VERDE de conexi n a tierra Cable de alimentaci n NEGRO o ROJO Cable VERDE de conexi n a tierra Cable de alimentaci n NEGRO o ROJO INSTRUCCIONES DE INSTALACI N Instalaci n general 1 Conecte el tubo de escape al sistema de escape exterior consulte las p ginas 54 a 56 Se recomienda usar una abrazadera pieza A de 4 10 2 cm para conectar las secadora al sistema de ventilaci n de escape Utilice cinta de papel de aluminio para sellar las dem s uniones 2 Deslice la secadora a su posici n final cuidadosamente Ajuste una o varias de las patas de la secadora hasta que se encuentre firme sobre las cuatro patas Coloque un nivel en la parte superior de la secadora La secadora DEBE estar nivelada y firme sobre las cuatro patas Presione las distintas esquinas para asegurarse de que la secadora est estabilizada Retire y deseche la cinta de la puerta mJ IMPORTANTE Revise la caja del interruptor autom tico fusibles para asegurarse de que la electricidad est desconectada antes de conectar el cable de alimentaci n al tomacorriente 3 Conecte el cable de alimentaci n a un tomacorriente con conexi n a tierra 4 Conecte la electricidad desde la caja del interruptor autom
47. irarlas Deseche el pestillo de metal viejo 3 Vuelva a voltear el conjunto de la puerta interior y ubique los 2 tornillos de cabeza alomada de la bisagra Retire y guarde estos 2 tornillos y separe la bisagra del conjunto de la puerta interior INVERSI N DE LA PUERTA 4 Desde la parte trasera de la puerta interior presione las leng etas de retenci n del tap n de pl stico cuadrado para liberarlo Guarde el tap n cuadrado para volver a instalarlo m s adelante 5 Retire cuidadosamente los 2 tapones redondos de la puerta interior y mu valos a los agujeros opuestos para reinstalarlos 6 Gire la bisagra y mu vala al lado opuesto de la puerta interior F jela con los 2 tornillos de cabeza alomada que retir anteriormente Vuelva a instalar el tap n pl stico en el agujero cuadrado junto a la bisagra INVERSI N DE LA PUERTA Reensamblaje de la puerta 1 Levante el anillo interior de vidrio G relo 180 grados vuelva a instalarlo en la puerta exterior alineando los indicadores LH para la bisagra izquierda o RH para la bisagra derecha 2 Recueste la abertura de la puerta interior a un ngulo de 90 grados sobre los soportes de la compuerta de la cubierta de la bisagra Gire la puerta interior hacia abajo sobre la puerta exterior 3 Vuelva a instalar los tornillos de cabeza corrugada no 1 5 retirados anteriormente Tenga cuidado de no da ar la rosca de los agujeros de pl stico
48. l P N CFPWD15N Pedestal de color rojo P N CFPWD15R Pedestal de color plateada P N CFPWD15A Pedestal de color negra P N CFPWD15B Un accesorio de pedestal de almacenamiento especialmente dise ado para esta secadora se puede utilizar para elevar la secadora y facilitar su uso Dicho pedestal agregar aproximadamente 38 1 cm 15 pulgadas a la altura de su unidad para una altura total de 134 62 cm 53 pulgadas Es posible que hayan otros colores disponibles P ngase en contacto con el distribuidor donde adquiri la secadora KIT DE SECADORA PARA CENTRO DE LAVADO Pieza No STACKIT4X Dependiendo del modelo que haya comprado es posible que esta secadora incluya un kit para instalarla sobre la lavadora correspondiente Si el modelo que adquiri no incluye un kit de instalaci n sobre la lavadora o desea un kit diferente puede pedir uno KIT DE CONVERSI N A GAS LP Pieza No PCK4200 Las secadoras a gas dise adas para el uso en lugares con suministro de LP requieren utilizar un kit de conversi n antes de la instalaci n KIT DE INSTALACI N EN UNA CASA RODANTE Pieza No 137067200 La instalaci n en una casa rodante requiere utilizar el KIT DE INSTALACION EN UNA CASA RODANTE REJILLA DE SECADO Pieza No 1370067300 Dependiendo del modelo que haya comprado es posible que esta secadora incluya una rejilla de secado Si el modelo que adquiri no incluye una rejilla de secado o desea una rejilla adicional puede pedir una
49. n los sistemas trifilares Terminal neutro 41 INSTRUCCIONES DE INSTALACI N Conexi n el ctrica fuera de Canad tetrafilar Recept culo tetrafilar tipo NEMA 14 30R 4 ADVERTENCIA PELIGRO DE DESCARGA EL CTRICA El no desconectar el suministro el ctrico antes de realizar cualquier reparaci n puede ocasionar lesiones personales o incluso la muerte 1 Desconecte el suministro el ctrico del tomacorriente 2 Extraiga el tornillo que sujeta la cubierta de acceso del bloque terminal que se encuentra en la esquina inferior de la parte trasera de la secadora 3 Instale un dispositivo de liberaci n de tensi n aprobado por U L de acuerdo con las instrucciones relativas al cable de alimentaci n dispositivo de liberaci n de tensi n del fabricante en el orificio de entrada del cable de alimentaci n debajo del panel de acceso En este momento el dispositivo de liberaci n de tensi n debe estar holgadamente en su lugar 4 Pase un cable de alimentaci n aprobado por U L DESENCHUFADO de 30 amp tipo NEMA 14 30 SRDT o ST a trav s del dispositivo de liberaci n de tensi n 5 Desconecte el cable interno NEGRO de conexi n a tierra que integra el enchufe preformado de la secadora del tornillo de conexi n a tierra VERDE que est junto al bloque terminal 6 Conecte el cable de conexi n a tierra VERDE del cable de alimentaci n al gabinete utilizando el to
50. nstallation TABLE OF CONTENTS Important Safety Instructions 2 3 REWEISING DOO avavanosmonaacosa AN 20 23 Installation Requiem ES 4 10 Ac Sorana a E T 24 Installed DryerDiMmens One 11 ES ON 25 Installation ANSIA 12 19 VOTT VOOLZrVLET IMPORTANT SAFETY INSTRUCTIONS 4 WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance 44 WARNING RISK OF FIRE Read all of the following instructions before installing and using this appliance e Destroy the carton and plastic bags after the dryer is unpacked Children might use them for play Cartons covered with rugs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children e Clothes dryer installation and service must be performed by a qualified installer service agency or the gas supplier e Install the clothes dryer according to the manufacturer s instructions and local codes e The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the Na tional Electrical Code ANSI NFPA 70 or in Canada the Canadian electrical code C22 1 part 1 e The gas service to the dryer must conform with local codes
51. o de aire de la secadora y aumentan el riesgo de incendio Si su sistema actual est compuesto de un conducto de pl stico o papel de aluminio reempl celo por un conducto de metal r gido o semir gido Aseg rese de que el conducto existente no tenga pelusas antes de instalar el conducto de la secadora 30 Incorrecto Correcto REQUISITOS DE INSTALACI N Requisitos del sistema de escape continuaci n 4 ADVERTENCIA PELIGRO DE INCENDIO Una secadora de ropa debe tener ventilaci n al exterior No ventile la secadora a una chimenea pared techo tico pasajes entre pisos ni ning n espacio oculto de la vivienda Las secadoras de ropa producen pelusa combustible Si la secadora no tiene ventilaci n al exterior algunas pelusas finas se expulsar n en el rea de lavander a La acumulaci n de pelusa en cualquier rea de la vivienda puede constituir un peligro sanitario y un riesgo de incendio La secadora debe estar conectada a un sistema de escape que termine en el exterior de la vivienda Inspeccione la abertura de escape al exterior con frecuencia y elimine cualquier acumulaci n de pelusa en la abertura y en el rea que
52. our gas supplier call the fire department future reference Pre I nstallation Requirements Tools and materials needed for installation e Adjustable pliers e Carpenter s level e Gas line shutoff valve gas dryer e Phillips straight amp square bit e External vent hood e 14 NPT union flare adapters x2 screwdrivers e 4 inch 102 mm rigid metal or and flexible gas supply line gas e Adjustable wrench semi rigid metal exhaust duct work dryer e Pipe wrench for gas supply gas e 3 wire or 4 wire 240 volt cord kit e Metal foil tape not duct tape dryer electric dryer e LP resistant thread tape for natu 4 in 102 mm clamp ral gas or LP supply gas dryer 2 IMPORTANT SAFETY INSTRUCTIONS 4 WARNING Please read all instructions before using this dryer Recognize safety symbols words and labels Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type as described below Definitions A This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death 4 DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury 4 WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a potentially hazard
53. ous situation which if not avoided may result in minor or moderate injury m IMPORTANT IMPORTANT indicates installation operation or maintenance information which is important but not hazard related vA Installation Checklist Exhaust Venting a Free flowing clear of lint buildup Q 4inch 102 mm rigid or semi rigid ducting of minimal length and turns A NO foil or plastic venting material U Approved vent hood exhausted to outdoors Leveling UA Dryer is level side to side and front to back QA Cabinet is setting solid on all corners Gas Supply Gas Dryer O Manual shutoff valve present in supply A All connections sealed with approved sealer and wrench tight A Conversion kit for LP system A Gas supply turned on A No leaks present at all connections check with soapy water NEVER check with flame 240v Electric Supply Electric Dryer OU Approved NEMA 10 30R or 14 30R service cord with all screws tight on terminal block O Approved strain relief installed a Terminal access cover installed before initial operation Door Reversal A Follow detailed instructions in this guide O Test hinge and latch for function Electrical Power A House power turned on A Dryer plugged in Final Checks Q Installation Instructions and Use and Care Guide read thoroughly A Door latches and drum tumbles when cycle starts QU Registration card sent in INSTALLATION REQUIREMENTS L NOTE Because of po
54. presi n exceda los 3 45 kPa 1 2 psig La secadora DEBE estar aislada de la tuber a de gas durante cualquier prueba en la que la presi n sea igual o inferior a 3 45 kPa 1 2 psig Las conexiones del suministro de gas deben cumplir con la norma de conexiones de electrodom sticos a gas ANSI 221 24 29 REQUISITOS DE INSTALACI N Requisitos del sistema de escape Utilice solo un conducto de metal flexible o r gido de 102 mm 4 pulgadas de di metro m nimo y una capucha de ventilaci n aprobada que tenga uno o m s reguladores de tiro que se abran cuando la secadora est en funcionamiento Cuando la secadora se detiene el regulador de tiro se cierra autom ticamente para evitar la corriente de aire y el ingreso de insectos y roedores Para evitar restringir la salida del conducto mantenga un espacio m nimo de 30 5 cm 12 pulgadas entre la capucha de ventilaci n y el suelo o cualquier otra obstrucci n 4 ADVERTENCIA PELIGRO DE INCENDIO El no seguir estas instrucciones puede producir tiempos de secado excesivos y peligro de incendio Los siguientes son requisitos necesarios para el funcionamiento seguro y correcto de su secadora 4 ADVERTENCIA PELIGRO DE INCENDIO No utilice materiales de ventilaci n de pl stico ni de papel de aluminio flexibles para instalar la secadora de ropa Por lo general dichos materiales se desarman se deterioran con facilidad y acumulan pelusa Estas condiciones obstruyen el fluj
55. rmite la instalaci n de la secadora a 0 75 2 cm de la pared e La ventilaci n hacia abajo con un codo de 90 permi te la instalaci n de la secadora a 0 75 2 cm de la pared e La ventilaci n hacia la izquierda con un adaptador recto corto y un codo de 90 permite la instalaci n a 3 75 9 5 cm de la pared e La ventilaci n hacia arriba con un adaptador recto corto y un codo de 90 permite la instalaci n a 4 10 2 cm de la pared Instalaci n en una casa rodante 1 La instalaci n DEBE cumplir con la actual Norma de Seguridad y Construcci n de Casas Rodantes t tulo 24 CFR Parte 32 80 que anteriormente se conoc a como la Norma Federal de Seguridad y Construcci n de Casas Rodantes Federal Standard for Mobile Home Construction and Safety t tulo 24 HUD parte 280 o la Norma CAN CSAZ240 MH 2 La secadora DEBE tener evacuaci n al exterior no a la parte de abajo de la casa rodante mediante conductos met licos que no admitan combusti n Los conductos met licos deben tener un di metro de 10 16 cm 4 pulgadas y no deben presentar obstrucciones Se recomiendan los conductos de metal r gido 3 Si la secadora tiene evacuaci n a trav s del piso y el rea debajo de la casa rodante es cerrada el Requisitos de despeje 4 ADVERTENCIA PELIGRO DE EXPLOSI N No instale la secadora en el mismo lugar en el que haya o se almacene gasolina u otros productos inflamables Si la secadora se instala en un
56. rnillo VERDE de conexi n a tierra Ajuste el tornillo con firmeza 7 Mueva el cable interno NEGRO de conexi n a tierra que integra el enchufe preformado de la secadora al bloque terminal y con ctelo junto con el conductor neutro BLANCO del cable de alimentaci n al terminal PLATEADO del centro del bloque terminal Ajuste el tornillo con firmeza 8 Conecte los conductores ROJO y NEGRO del cable de alimentaci n a los terminales externos de color LATON del bloque terminal Ajuste los dos tornillos con firmeza 4 ADVERTENCIA PELIGRO DE DESCARGA EL CTRICA No forme un ngulo agudo con el cableado conductor ni los doble en el punto de conexi n 9 Siga las pautas del fabricante para sujetar firmemente el dispositivo de liberaci n de tensi n y el cable de alimentaci n 10 Vuelva a instalar la cubierta del bloque terminal 42 wa p gt Neutro cable BLANCO 30 AMP Tierra NEMA 14 30 cable VERDE Tornillo de cubierto de acceso Tablero de terminales Neutro terminal PLATEADA L nea 1 terminal de LATON Connexi n tierra interna y tornillo VERDE o Instale aqu un dispositivo de liberaci n de tensi n aprobado por U L Ranura de recuperaci n de tornillos del terminal amp NOTA Si un tornillo del terminal se cae durante la instalaci n del cable se puede recuperar en la ranura de recuperaci n de tornillos del term
57. rom your local hardware supplier Extension hose must meet qualifications for use in laundry installation COLD WATER SUPPLY 7 Thread the Y connector to the short extension HOSE TO WASHER hose and snug it by hand then tighten it another Laundry hose extension not included with dryer 2 3 turn with pliers 8 Connect the COLD inlet hose for the washer to the Y connector and snug it by hand then tighten it another 2 3 turn with pliers 9 Connect the straight end of the long hose from the kit to the other outlet on the Y connector and snug it by hand Connect the hose s 90 coupling to the brass water inlet on the back of the dryer and snug it by hand Tighten each connection of the dryer inlet hose another 2 3 turn with pliers 10 Turn on the water and check for leaks at all connections 16 INSTALLATION INSTRUCTIONS Electrical connection non Canada 3 wire cord 3 wire receptacle NEMA type 10 30R 4h WARNING ELECTRICAL SHOCK HAZARD Failure to disconnect power source before servicing could result in personal injury or even death 1 Turn off power supply to outlet 2 Remove the screw securing the terminal block access cover in the lower corner on the back of the dryer 3 Install a UL approved strain relief according to the power cord strain relief manufacturer s instructions in the power cord entry hole below the access panel At this time the str
58. roved Mobile Home Installation Kit P N 137067200 IMPORTANT DO NOT INSTALL YOUR DRYER 1 2 In an area exposed to dripping water or outside weather conditions In an area where it will come in contact with curtains drapes or anything that will obstruct the flow of combustion and ventilation air On carpet Floor MUST be solid with a maximum slope of 1 inch 2 54 cm INSTALLATION REQUIREMENTS Clearance requirements continued Installation in a Recess or Closet MINIMUM INSTALLATION CLEARANCES Inches cm er P smes Rem tor FRONT 1 A dryer installed in a bedroom bathroom recess or 0710 cm 0 emPfo 0 em closet MUST be exhausted outdoors 2 No other fuel burning appliance shall be installed in 0 0 cm 0 0 cm 0 0 cm the same closet as the gas dryer Closet 0 0 cm 0 0 cm 0 0 cm 1 2 54 cm 3 Your dryer needs the space around it for proper Closet_ 0 0 cm jo 0 cm o 0 cm 1 2 54 cm Jati Dryer must be vented straight back to achieve ventilation 0 0 cm rear installation DO NOT install your dryer in a closet with a solid door 4 Closet door ventilation required A minimum of 120 square inches 774 2 cm of opening equally divided at the top and bottom of the door is required Openings should be located 3 inches 7 6 cm from bottom and top of door Openings are required to be unobstructed when a door is installed A louvered door
59. talled within 42 inches 107 cm of your dryer s water inlet The faucet MUST be 3 4 inch 1 9 cm with threading for laundry hose con nection Water pressure MUST be between 30 and 120 psi Your water department can advise you of your water pressure 1 Turn off COLD water supply to washer 2 Remove COLD inlet hose from COLD water supply and inspect for rubber washer Replace washer if it is torn or worn out MUST BE PRESENT AND UNDAMAGED COLD INLET HOSE TO WASHER 3 Momentarily turn on COLD supply and run some water into a bucket or container to clear any contaminants in the line 4 Remove hose kit from dryer drum and inspect hose couplings for proper placement of rubber washers RUBBER WASHERS MUST BE PRESENT 15 INSTALLATION INSTRUCTIONS Water connection continued Steam Model only 5 If your installation has room for the COLD water supply to accept the Y connector directly thread DIRECT CONNECTION the Y connector to the COLD water supply and OR WITH EXTENSION snug it by hand then tighten it another 2 3 turn with pliers WATER INLET ON DRYER amp NOTE If you were able to install the Y connector directly to the COLD water supply please skip to step 8 6 If there is not room to install the Y connector directly thread a short extension hose on to the COLD water supply and snug it by hand then tighten it another 2 3 turn with pliers L NOTE Short extension available f
60. tentially inconsistent voltage capabilities the use of this dryer with power created by gas powered generators solar powered generators wind powered generators or any other generator other than the local utility company is not recommended Electrical requirements for electric dryer CIRCUIT Individual 30 amp branch circuit fused with 30 amp time delay fuses or circuit breakers Use separately fused circuits for washer and dryer DO NOT operate a washer and a dryer on the same circuit POWER SUPPLY 3 wire or 4 wire 240 volt single phase 60 Hz Alternating Current m IMPORTANT This dryer is internally grounded to neutral unless it was manufactured for sale in Canada Only a 4 conductor cord shall be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited Grounding through the neutral link is prohibited for 1 new branch circuit installations 2 mobile homes 3 recreational vehicles and 4 areas where local codes do not permit grounding through the neutral OUTLET RECEPTACLE NEMA 10 30R or NEMA 14 30R receptacle to be located so the power supply cord is accessible when the dryer is in the installed position GROUNDING CONNECTION See Grounding requirements in Electrical Installation section 3 WIRE POWER SUPPLY CORD KIT not supplied 4 WIRE POWER SUPPLY CORD KIT not supplied 3 wire receptacle 4 wire receptacl
61. trica segura y correcta de su secadora El no seguir estas instrucciones puede producir una descarga el ctrica y o incendio ADVERTENCIA PELIGRO DE DESCARGA EL CTRICA Este electrodom stico DEBE estar debidamente conectado a tierra Si la secadora no est conectada a tierra correctamente se pueden producir descargas el ctricas Siga las instrucciones de esta gu a para ver c mo se realiza una correcta conexi n a tierra No utilice un cable de extensi n con esta secadora Algunos cables de extensi n no est n dise ados para soportar la cantidad de corriente el ctrica que utiliza esta secadora y pueden derretirse lo que constituye un peligro de descarga el ctrica y o incendio Ubique la secadora en un lugar donde el cable de alimentaci n que compre est al alcance del recept culo permitiendo que el cable quede holgado Consulte los requisitos de preinstalaci n de esta gu a para ver cu l es el cable de alimentaci n correcto que se debe comprar INSTRUCCIONES DE INSTALACI N A ADVERTENCIA PELIGRO DE DESCARGA EL CTRICA e Debe instalarse en el cable de alimentaci n un dispositivo de liberaci n de tensi n aprobado por U L Si no se coloca un dispositivo de liberaci n de tensi n el cable podr a desenchufarse de la secadora y cortarse por cualquier movimiento y provocar as una descarga el ctrica e No utilice un recept culo con cableado de aluminio para un enchufe y cable de alimentaci n con cables de
62. tro del bloque terminal Ajuste el tornillo con firmeza 6 Conecte los dos conductores externos restantes del cable de alimentaci n a los terminales externos de color LATON del bloque terminal Ajuste los dos tornillos con firmeza 4 ADVERTENCIA PELIGRO DE DESCARGA EL CTRICA No forme un ngulo agudo con el cableado conductor ni los doble en el punto de conexi n 7 Siga las pautas del fabricante para sujetar firmemente el dispositivo de liberaci n de tensi n y el cable de alimentaci n 8 Vuelva a instalar la cubierta del bloque terminal ma IMPORTANTE Para mover la secadora desde un sistema tetrafilar e instalarla en un sistema trifilar mueva la conexi n a tierra interna del terminal central nuevamente hacia el tornillo VERDE que se encuentra junto al bloque terminal Neutro cable central Tornillo de cubierto de acceso Tablero de terminales L nea 2 terminal de LAT N Neutro terminal PLATEADA L nea 1 A terminal de LATON Connexi n tierra interna tornillo VERDE o Instale aqu un dispositivo de liberaci n de tensi n aprobado por U L Ranura de recuperaci n de tornillos del terminal LAAN o L NOTA Si un tornillo del terminal se cae durante la instalaci n del cable se puede recuperar en la ranura de recuperaci n de tornillos del terminal que se encuentra debajo del panel de acceso NO retire la conexi n interna a tierra e
63. ve An L P conversion kit must be installed by a qualified gas technician 2 Connect a 1 2 inch 1 27 cm D semi rigid or approved pipe from gas supply line to the 3 8 inch 0 96 cm pipe located on the back of the dryer Use a 1 2 inch to 3 8 inch 1 27 cm to 0 96 cm reducer for the connection Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections Manual Shutoff Valve UE LL a Ho GAS FLOW Flare Union Flare Union f Nipple ised a Open Inlet Pipe on Back of Dryer Flexible Connector All connections must be wrench tightened ma IMPORTANT The supply line must be equipped with an approved manual shutoff valve This valve should be located in the same room as the dryer and should be in a location that allows ease of opening and closing Do not block access to the gas shutoff valve 14 3 Open the shutoff valve in the gas supply line to allow gas to flow through the pipe Wait a few minutes for gas to move through the gas line Shutoff Valve Open position 4 Check for gas system leaks with a manometer If a manometer is not available test all connections by brushing on a soapy water solution 4h WARNING EXPLOSI ON HAZARD NEVER test for gas leaks with an open flame INSTALLATION INSTRUCTIONS Water connection Steam Model only WATER SUPPLY REQUIREMENTS Cold water faucet MUST be ins
64. with equivalent air openings for the full length of the door is acceptable AAN E 7 6cm t 60 sq in 387 1cm y 2 54cm 60 sq in 387 1cm f fem M closet door 10 INSTALLED DI MENSI ONS 51 4 131cm to clear open door A 30 3 77cm A to front of closed d G 27 0 68 5cm electrical supply on rear of unit centerline height for gas supply rear vent freestand dryer pipe on rear on floor of gas unit floor line dryer mounted on optional pedestal 19 0 48cm floor line To obtain these minimal depth dimensions dryer must be vented straight back Using a quick turn 90 3 75 elbow right or down on freestanding dryer adds approximately 0 75 in 2 0 cm to installation depth 9 5cm Upward venting of exhaust on pedestal mounted or freestanding dryer adds approximately 4 in 10 2 cm to installation depth Leftward venting on pedestal mounted or freestanding dryer adds approximately 3 75 in 9 5 cm to installation depth Downward venting of exhaust on pedestal mounted dryer adds approximately 2 25 in 5 7 cm to installation depth 4 13 50 34 5cm to center of rear vent 51 4 131 cr _ _ _ _ _ gt gt to clear open door le 30 3 77c0 lt t
65. yer MUST be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current 2 After you purchase and install a 3 wire or 4 wire power supply cord having an equipment grounding conductor and a grounding plug that matches your 12 wiring system the plug MUST be plugged into an appropriate copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances If in doubt call a licensed electrician 3 DO NOT modify the plug you ve installed on this appliance If it will not fit the outlet have a proper outlet installed by a qualified electrician For a permanently connected dryer 1 The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance INSTALLATION INSTRUCTIONS Grounding requirements Electric dryer Canada 4h WARNING ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded For a grounded cord connected dryer 1 The dryer MUST be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical shock by a p

Download Pdf Manuals

image

Related Search

Related Contents

Manual B-Speech Medo(eng)  DN-7061_manual_manual english_20110704  保 証 書  Quick SC Installation manual  Owner`s Manual - TV Connections  Insulation Testers (3213A, 2406E, MY10, 2406D, MY40)  取扱説明書[EH-NE55] (1.82 MB/PDF)  Le permis de feu  プレート&シートプリンター PP550 取扱説明書  Corsair Dominator Platinum, 16GB (4x4GB), DDR3  