Home

Franke Consumer Products FDL 364 W Ventilation Hood User Manual

image

Contents

1. et vous comment l utiliser correctement 2 Le feu est faible et peu r pandu 3 Les pompiers sont d j pr venus 4 Vous conservez une sortie derri re vous TOUTE OUVERTURE DANS LE MUR OU LE PLANCHER PROXIMIT DE LA HOTTE DOIT SCELLE Gardez 24 po de hauteur entre le bas de la hotte et la surface de cuisson Consultez la fiche tech nique avant de d couper les armoires INSTALLATION DANS UNE MAISON MOBILE L installation de cette hotte doit tre conforme aux r glements de Manufactured Home Construc tion and Safety Standards Titre 24 CFR Section 3280 anciennement Federal Standard for Mo bile Home Construction and Safety Titre 24 HUD Section 280 Le branchement lectrique s effectue avec un raccordement 4 fils Consultez la Fiche Technique lectrique EXIGENCES DE VENTILATION VACUATION ATTENTION Afin de r duire le risque d incendie et pour bien vacuer l air assurez vous de faire chap per l air des conduits l ext rieur Ne jamais vacuer l air vers des espaces comportant des murs ou des plafonds ou dans le grenier la galerie ou le garage D terminer la m thode d vacuation de lair la plus appropri e pour application La sortie d evacuation soit par le mur soit par le toit Utilisez une longueur de tuyauterie minimale incluant le moins de coudes possible pour une plus grande efficacit Le calibre de la tuyauterie doit tre uni forme N installez jamais 2 coudes
2. Fixer le panneau arri re le cas ch ant avec les vis 12a fournies Montage du corps de la hotte Vis les deux vis 12d accompagnant les supports 7 1 Accrocher le corps de hotte sur le support 7 1 en le centrant autour de la ligne verticale Utiliser les vis de r glage 12d en dessous de la hotte pour mettre le corps de hotte niveau Note Le corps de hotte doit tre fix aux goujons muraux Si n cessaire installer un support en bois derri re le mur sec mont ras des 2 goujons Cela assurera la structure requise et le sup port de montage Branchements SORTIE D AIR VERSION ASPIRANTE En cas d installation en version aspirante brancher la hotte la tuyauterie de sortie via un tube rigide de 6 po Installer le clapet d air 10 6 po Fixer le tube par des colliers appropri s Le mat riel n ces saire n est pas fourni SORTIE D AIR VERSION NON CAR N ES Placer le raccord 15 dans le support de connexion 7 3 Fixer au support avec les 2 vis 12e fournies Raccorder la connexion de sortie d air 15 la sortie du corps de hotte avec un tuyau rigide de diam tre 6 po non inclus S assurer que les filtres charbon activ ont t ins r s 1 P L 1 a 1 1 1 91023 29 BRANCHEMENT LECTRIQUE e Retirer le couvercle du compartiment de filage l aide d un vis moue Fil de masse tournevis Phillips Passer le c ble d alimen
3. discon necting means to prevent power from being switched on accidentally When the service discon necting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For General Ventilating Use Only Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Installation Work And Electrical Wiring Must Be Done By Qualified Person s In Accordance With All Applicable Codes And Standards In cluding Fire Rated Construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors e Electrical ground is required on this rangehood e If cold water pipe is interrupted by plastic nonmetallic gaskets or other materials DO NOT use for grounding DO NOT ground to a gas pipe DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or gro
4. ensembles Scellez bien tous les joints avec un ruban adh sif m tallique l int rieur et scellez bien le clapet ext rieur en utilisant du calfeutrage L utilisation d un tuyau d vacuation flexible n est pas recommand e Les tuyaux flexibles cr ent une contre pression et de la turbulence ce qui r duit la puissance d vacuation Veillez ce que l espace pour le tuyau soit amplement suffisant ainsi vous n aurez pas d cou per les supports de mur int rieur On ne doit couper une solive ou un poteau de colombage que lorsque cela est absolument n cessaire S il est n cessaire de couper une solive ou un poteau du colombage on doit construire une structure de support appropri e AVERTISSEMENT Afin de r duire le risque d incendie utilisez seulement des conduits en m tal Le syst me d vacuation DOIT se terminer l ext rieur e N VACUEZ PAS le conduit dans un grenier ou dans tout autre espace ferm e N UTILISEZ PAS un clapet de s cheuse 4 pouces e D CONSEILLE l emploi de conduit d vacuation flexible e N ENCOMBREZ PAS la circulation d air Le fait de ne pas respecter ces avertissements pourrait occasionner un incendie FICHE TECHNIQUE LECTRIQUE Le raccordement lectrique doit se faire avec un circuit s par de 15 amp res fusibles 120 V 60 Hz courant alternatif Nous recommandons un coupe circuit La taille du fusible doit se conformer aux codes municip
5. rence Marquer le mur au niveau des centres des trous du support e Placer le support 7 2 1 sur le mur comme indiqu X en dessous du premier support X hauteur de la section sup rieure de chemin e incluse en alignant le centre entaille sur la ligne verticale e Marquer le mur au niveau des centres des trous du support e Placer le support 7 1 comme indiqu 4 5 16 de la ligne verticale de r f rence et 7 po 1 2 au dessus de la ligne horizontale de r f rence e Marquer les centres des trous du support e R p ter la m me op ration de l autre c t PANNEAU ARRI RE OPTION Le panneau arri re doit tre mont avant de fixer le corps de hotte et s il doit tre fix en haut et en bas il doit tre mont la bonne hauteur avant d installer les bases Cette op ration tant plut t complexe elle doit tre ex cut e par le monteur de la cuisine ou toute autre personne qualifi e connaissant les dimensions d finitives des unit s Pour fixer en haut seulement proc der comme suit Faire reposer le panneau arri re sur la base en ins rant le plateau inf rieur entre la surface sup rieure et le mur et en le centrant sur la ligne verticale de r f rence Marquer les centres des deux trous du plateau sup rieur e Percer des trous de 5 16 de diam tre sur tous les points marqu s Ins rer les fiches murales 11 dans les trous e Fixer les supports avec les vis 12a fournies e
6. supplied Ensure that the activated charcoal filters have been inserted 1 1 4 ae 1 1 r 11 1 e 1 lt 88 ELECTRICAL CONNECTION e Remove the cover from the Field Wiring Compartment with a phillips screwdriver Ground Feed the Power Supply Cable through the electrical knockout Connect the Power Supply Cable to the range hood cable At tach the Power Supply Cable grounding lead to the green screw provided Attach the White lead of the power supply to the White lead of the rangehood with a twist on type wire connec tor Attach the Black lead of the power supply to the Black lead of the rangehood with a twist on type wire connector Replace the cover Ground wire Power supply cable Chimney assembly Upper exhaust Chimney Slightly widen the two sides of the upper flue and hook them behind the brackets 7 3 and 7 2 1 making sure that they are well seated e Secure the sides to the brackets using the 4 screws 12c sup plied Make sure that the air outlet connection is aligned with the chimney outlets Lower exhaust Chimney Slightly widen the two sides of the chimney and hook them between the upper chimney and the wall making sure that they S are well seated Fix the lower part laterally to the hood body using the 2 screws 12c supplied USE Control board Light Switches the lighting system on
7. AX 36 1 4 22 1 16 26 3 8 9 7 16 35 7 16 9 Composantes Ref Qt Pi ces du produit 1 1 Corps de la hotte quip de commandes lumi re groupe ventilateur filtres 2 1 Chemin e t lescopique form e 2 1 1 Chemin e sup rieure 2 2 1 Chemin e inf rieure 10 1 Clapet anti reflux 15 1 Raccord de sortie d air Ref Qt Pi ces servant l installation 7 1 2 Brides de montage de la hotte 7 2 1 1 Brides de montage de la chemin e sup rieure 7 3 1 Bride de raccord de sortie d air 11 8 _Chevilles si fournies 12a 8 Vis 3 16 x 1 3 4 12c 6 Vis 1 8 x 3 8 12d 2 Vis 3 16 x1 12e 2 Vis1 8 x1 2 Qt Documentation 1 Manuel d instructions INSTALLATION Per age de la paroi et fixation des brides 116 IT T gt lt 2 Ez 721 2 24 Marquage au mur Tracer une ligne verticale sur le mur de support jusqu au plafond ou aussi haut que n ces saire au centre de la surface sur laquelle la hotte sera install e Tracer une ligne horizontale 24 po au dessus du piquet pour installation sans panneau ar ri re la hauteur hauteur de la partie visible pour l installation avec panneau arri re e Placer le support 7 3 sur le mur comme indiqu environ 1 16 po du plafond ou de la li mite sup rieure en alignant le centre entaille sur la ligne verticale de r f
8. FRANKE PRESTIGE 30 PRESTIGE 36 Range Hood Hotte Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien FDL 304 W FDL 364 W INDEX WARNINGS AND REQUIREMENTS RECOMMENDATIONS AND SUGGESTIONS 6 DIMENSIONS and MAIN PARTS wal INSTALLATION 8 USE e rs r A 11 12 READ AND SAVE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner The homeowner must keep these instructions for future reference and for local electrical inspec tors use READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium setting Always turn hood ON when cooking at high heat or when flamb ing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting lid cookie sheet or metal tr
9. Replace the metal grease filters Lighting LIGHT REPLACEMENT 20 W halogen light Remove the 2 screws fixing the Lighting support and pull it out of from the Hood Extract the lamp from the Support Replace with another of the same type making sure that the two pins are properly inserted in the lamp holder socket holes Replace the Support fixing it in place with the two screws re moved as above TABLE DES MATI RES AVERTISSEMENT ET CONDITIONS N ECESSAIRES nus 14 CONSEILS ET SUGGESTIONS nan una kl n lan G z R lad DIMENSIONS etPRINCIPALES PI CES INSTALLATION css SOIN ETENTRETIEN nania a an LIRE CONSERVER CES INSTRUCTIONS L installateur doit laisser ces instructions au propri taire Le propri taire doit conserver ces instructions en vue d une utilisation subs quente et pour le b n fice de l inspecteur en lectricit LISEZ BIEN CETTE FICHE AVANT D UTILISER LA HOTTE AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA CUISI NIERE Ne jamais laisser un l ment de la surface fonctionner sans surveillance la puissance de chauffage maximale un renversement d bordement de mati re graisseuse pourrait provoquer un incendie ou causer de la fum e Utiliser toujours une puissance de chauffage moyenne ou basse pour faire chauffer de l huile Veiller toujours faire fonctionner le ventilateur de la hotte lor
10. and off S Led Motor running led V1 Motor Switches the extractor motor on and off at low speed Used to provide contin uos and silent air change in the presence of light cooking vapours V2 Speed Medium speed suitable for most operating conditions given the optimum treated air flox noise level ratio Intensive Maximum speed used for eliminating the highest cooking vapour emission including long periods CARE Metal Grease filters CLEANING METAL SELF SUPPORTING GREASE FILTERS The filters must be cleaned every 2 months of operation or more frequently for particularly heavy usage and can be washed in a dishwasher Remove the filters one by one by pushing them backwards and pulling them down contemporaneously Wash the filters Pay attention not to bend them Make sure that filters are completely dry before putting them into their seat a possible modification of the filter surface doesn t influ ence its efficiency Place the filters again into their seats and make sure that the handle of the filter remain outside Activated charcoal filter Ductless version These filters not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or B more frequently with heavy usage REPLACING THE ACTIVATED CHARCOAL FILTER Remove the metal grease filters e Remove the saturated activated charcoal filter as shown Fit the new filters
11. aux suivant la sp cification lectrique sur la plaque int rieure CET APPAREIL DOIT TRE CONNECTE QU EN UTILISANT DES FILS EN CUIVRE Le diam tre du fil devra aussi se conformer aux r glements du code national lectrique ANSI NFPA 70 ainsi qu aux r glements locaux et les sp cifications de cet appareil On peut ob tenir ces informations aupr s de National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Raccordez cet appareil directement au coupe circuit ou au disjoncteur par l interm diaire de c ble conducteurs de cuivre blindage m tallique flexible ou gaine non m tallique Un serre c ble de 1 po 12 7 mm homologation UL ou CSA doit tre install chaque extr mit du c ble d alimentation sur la hotte et sur le bo tier de distribution Faites un trou de 1 1 4 po dans le mur S il s agit d un mur en bois sablez bien le trou Tandis qu un trou dans le m tal demande un oeillet passe fil AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE OU DE CHOC LECTRI QUE ne pas utiliser ce ventilateur en conjonction avec un dispositif de r glage de vitesse semi conducteurs AVERTISSEMENT POUR MINIMISER LES RISQUES D INCENDIE CHOC LECTRI QUES OU BLESSURES OBSERVER CETTE R GLE suivez strictement les recommandations du fabricant en cas de n cessit veuillez le contacter Avant d entreprendre un travail d entretien ou de nettoyage interromp
12. ay then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST SEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured Home Construction and Safety Standards Title 24 CFR Part 3280 formerly Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements VENTING REQUIREMENTS CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent ex haust air into spaces within walls or ceilings or into attics crawl spaces or garages Determine which venting meth
13. fixing gt 116 EEE EDED KEN eza ES Ba ET GEE __ 1 Wall marking Draw a vertical line on the supporting wall up to the ceiling or as high as practical at the center of the area in which the hood will be installed Draw a horizontal line at 24 above the hob for installation without the back panel or at height H height of the visible part of the panel for installation with the back panel Place bracket 7 3 on the wall as shown about 1 16 from the ceiling or upper limit aligning the center notch with the vertical reference line Mark the wall at the centers of the holes in the bracket Place bracket 7 2 1 on the wall as shown at X below the first bracket X height of the up per chimney section supplied aligning the center notch with the vertical line Mark the wall at the centers of the holes in the bracket Place bracket 7 1 as shown 4 5 16 from the vertical reference line and 7 1 2 above the horizontal reference line Mark the centres of the holes in the bracket Repeat this operation on the other side REAR PANEL OPTIONAL The Rear Panel must be fitted before fixing the hood body and if it is to be fixed at both top and bottom must be fitted at the correct height prior to installing the bases As this operation is rather complex it should be carried out either by the kitchen installer or a qualified person who kno
14. l rating plate located inside the unit near the field wiring compartment THIS UNIT MUST BE CONNECTED WITH COP PER WIRE ONLY Wire sizes must conform to the requirements of the National Electrical Co de ANSI NFPA 70 latest edition and all local codes and ordinances Wire size and connections must conform with the rating of the appliance Copies of the standard listed above may be obtai ned from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 This appliance should be connected directly to the fused disconnect or circuit breaker through flexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the ap pliance can be moved if servicing is ever necessary UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at the appliance and at the junction box When making the electrical connection cut a 1 1 4 hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufac turer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service
15. le moteur aspiration vitesse minimale pour un rechange d air permantent particuli rement silencieux cas de faibles va peurs de cuisson V2 Vitesse Vitesse moyenne pour la plupart des conditions d utilisation tant donn le rapport optimal entre d bit d air trait et niveau sonore V3 Vitesse Vitesse maximum pour faire face aux missions maximum de vapeur de cuisson m me pendant des temps prolong s SOIN ET ENTRETIEN Filtres anti graisse NETTOYAGE FILTRES ANTI GRAISSE METALLIQUES AUTOPORTEURS Lavables au lave vaisselle ils doivent tre lav s environ tous les 2 mois d emploi ou plus fr quemment en cas d emploi par ticuli rement intense Enlevez les filtres l un apr s l autre en les soutenant avec une main et en tirant en m me temps la poign e vers le bas avec l autre main e Laver les filtres en vitant de les plier et les laisser s cher avant de les remonter Remonter les filtres en veillant ce que la poign e reste vers la partie visible externe Filtre anti odeur Version filtrante Les filtres ne sont pas fournis avec la ne sont pas lava bles ni r g n rables il faut les remplacer au moins tous les 4 mois d emploi ou plus fr quemment cas d emploi particuli rement intense REMPLACEMENT FILTRE AU CHARBON ACTIF e Retirer les filtres anti graisse m talliques Retirer les filtres anti odeur au charbon actif satur s c
16. od is best for your application Ductwork can extend either through the wall or the roof The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance The size of the ductwork should be uni form Do not install two elbows together Use duct tape to seal all joints in the ductwork system Use caulking to seal exterior wall or floor opening around the cap Flexible ductwork is not recommended Flexible ductwork creates back pressure and air turbu lence that greatly reduces performance Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed WARNING To Reduce The Risk Of Fire Use Only Metal Ductwork Venting system MUST terminate outside the home DO NOT terminate the ductwork in an attic or other enclosed space DO NOT use 4 laundry type wall caps e Flexible type ductwork is NOT recommended DO NOT obstruct the flow of combustion and ventilation air Failure to follow venting requirements may result in a fire ELECTRICAL REQUIREMENTS 120 volt 60 Hz AC only electrical supply is required on a separate 15 amp fused circuit A timedelay fuse or circuit breaker is recommended The fuse must be sized per local codes in ac cordance with the electrical rating of this unit as specified on the seria
17. omme indiqu A Monter les nouveaux filtres Remonter le filtres anti graisse m talliques clairage REMPLACEMENT DES AMPOULES Lampe halog ne de 20 W Retirer les 2 vis qui fixent le support clairage et retirer ce der nier de la hotte e Extraire l ampoule du support Remplacer par une nouvelle ampoule poss dant les m mes ca ract ristiques en veillant ce que les deux fiches soient correctement ins r es dans le logement de la douille Remonter le support en le fixant l aide des deux vis pr c demment retir es FRANKE 436003931 01 070711
18. onduit de ventilation doit toujours se terminer l ext rieur AVERTISSEMENT Une prise la terre est n cessaire pour cette hotte e N UTILISEZ PAS un tuyau l eau froide pour la mise la terre s il est connect du plastique un joint non m tallique ou autre mat riel N EFFECTUEZ PAS la mise la terre sur la conduite de gaz NE PAS INSTALLER un fusible dans le conducteur neutre ou le conducteur de liaison la terre V rifiez avec un lectricien qualifi que la hotte est bien mise la terre Le fait de ne pas respecter ces avertissements pourrait occasionner un incendie CONSEILS ET SUGGESTIONS A Les instructions d utilisation s applique plusieurs versions de ce type d appareil En cons quence il est possible que vous trouviez des descriptions de caract ristiques ne s appliquant pas votre appareil INSTALLATION Le fabricant d cline toute responsabilit en cas de dommage une installa tion inad quate ou non conforme aux r gles de l art V rifiez que la tension du secteur correspond la valeur qui figure sur la pla quette appos e l int rieur de la hotte L alimentation lectrique doit tre ad quatement et suffisamment mise la terre Connectez la hotte la sortie de l air aspir l aide d une tuyauterie d un dia n sup rieur 6 po Le parcours de la tuyauterie doit tre le plus court possible vitez de connecter la hotte des conduite
19. r purposes other than for which it has ben designed Never leave high naked flames under the hood when itis in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames The hood should not be used by children or persons not instructed in its cor rect use CARE Switch off or unplug the appliance from the main supply before carrying out any maintenance work Clean and or replace the Filters after the specified time period Clean the hood using a damp cloth and a neutral liquid detergent DIMENSIONS and MAIN PARTS Dimensions MAX 36 1 4 22 1 16 MIN 267 3 8 977 16 30 Zi lt Components Ref Q ty Product Components 1 1 Hood Body complete with Controls Light Blower Filters 2 1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 _Lower Section 10 1 Damper 15 1 Air Outlet Connection Ref Q ty Installation Components 7A 2 Hood Body Fixing Brackets 7 2 1 1 Upper Chimney Section Fixing Brackets 7 3 1 _Air Outlet Connection Support 11 8 Plugs if supplied 12a 8 Screws 3 16 x 1 3 4 12c 6 Screws 1 8 3 8 14 2 Screws 3 16 x 1 12e 2 Screws 1 8 x 1 2 Q ty Documentation 1 Instruction Manual INSTALLATION Wall drilling and bracket
20. re l alimentation de la hotte au niveau du tableau de disjoncteur et verrouiller le tableau de disjoncteur pour emp cher tout r tablissement accidentel de l alimentation du circuit Lorsqu il n est pas possible de ver rouiller le tableau de disjoncteur une tiquette d avertissement pro minent interdisant le r tablis sement de l alimentation IMPORTANT Pour une ventilation de type g n ral seulement Ne pas utiliser cet appareil pour l vacuation de mati res ou vapeurs explosives AVERTISSEMENT POUR MINIMISER LES RISQUES D INCENDIE CHOC LECTRI QUES OU BLESSURES OBSERVER CETTE R GLE l installation et le raccordement lectrique ne doivent tre effectu s que par un technicien s qualifi selon tous les codes municipaux Afin d obtenir un rendement maximal en ce qui a trait la combustion ainsi qu l vacuation des gaz par la conduite de chemin e et pour qu il pas de reflux des gaz de combus tion une bonne a ration est n cessaire pour tous les appareils combustion Suivez les conseils et mesures de s curit du fournisseur tels que ceux publi s par la National Fire Pro tection Association NFPA et l American Society for Heating Refrigeration and Air Condition Engineers ASHRAE ainsi que les codes municipaux Lors d op ration de d coupage et de per age dans mur ou un plafond veiller ne pas endommager les c blages lectriques ou canalisations qui peuvent s y trouver Un c
21. s d une cuisson avec une puissance de chauf fage lev e ou lors de la cuisson d un mets flamber i e Cr pes Suzette Cherries Jubilee Peppercorn Beef Flamb Nettoyer fr quemment les ventilateurs d extraction Veiller ne pas laisser de la graisse s accumuler sur les surfaces du ventilateur ou des filtres Utiliser toujours un ustensile de taille appropri e AVERTISSEMENT POUR R DUIRE LE RISQUE DE DOMMAGES CORPORELS APR S LE D CLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINI RE APPLIQUER LES RE COMMANDATIONS SUIVANTES Blessures en cas de feu suivre les recommandations suivantes TOUFFEZ LE FEU AVEC UN COUVERCLE M TALLIQUE FERMEZ LE FAITES ATTENTION DE NE PAS VOUS BRULER SI LE FEU NE S TEINT PAS IMM DIATEMENT quit tez les lieux et appelez les pompiers ne touchez jamais une casserole en flammes VOUS POURRIEZ SUBIR DES BLESSURES N UTILISEZ JAMAIS DE L EAU OU UN TORCHON MOUILL POUR TEINDRE LE FEU CE QUI POURRAIT CAUSER UNE EXPLOSION DE VAPEUR vapeur br lante Utiliser un extincteur SEULEMENT si 1 Il s agit d un extincteur de classe ABC dont on conna t le fonctionnement 2 Il s agit d un petit feu encore limit l endroit o il s est d clar 3 Les pom piers ont t contact s 4 Il est possible de garder le dos orient vers une sortie pendant l op ration de lutte contre le feu N utilisez un extincteur que si 1 Vous avez sous la main un mod le
22. s d vacuation de fum es issues d une combustion tel que une chaudi re une chemin e etc Si vous utilisez des appareils qui ne fonctionnent pas l lectricit dans la pi ce ou est install e la hotte par exemple des appareils fonctionnant au gaz vous devez pr voir une a ration suffisante de l espace Si la cuisine en est d pourvue pratiquez une ouverture qui communique avec l ext rieur pour garantir l infiltration de l air pur BELARN La hotte a t con ue exclusivement pour un usage domestique dans le but d liminer les odeurs de la cuisine Ne jamais utiliser la hotte de mani re abusive pas laisser les flammes libres forte intensit lorsque la hotte est en ser vice Toujours r gler les flammes de mani re viter toute sortie lat rale de ces derni res par rapport au fond des casseroles Contr ler les friteuses lors de l utilisation car l huile surchauff e pourrait s enflammer La hotte ne doit pas tre utilis e par des enfant ou des personnes ne pouvant pas en assurer une utilisation ad quate ENTRETIEN Avant de proc der toute op ration d entretien retirer la hotte en la d bran chant ou en la mettant hors circuit Effectuer un entretien scrupuleux et en temps voulu des filtres Pour le nettoyage des surfaces de la hotte il suffit d utiliser un linge humide et un d tergent liquide neutre DIMENSIONS et PRINCIPALES PI CES Dimensions M
23. tation dans la pastille enfon able Brancher le c ble d alimentation sur la hotte le conducteur de mise la terre du c ble d alimentation la vis verte fournie Attacher le fil blanc du c ble d alimentation au fil blanc de la hotte avec une cosse connecteur de fils Atta cher le fil noir du c ble d alimentation au fil noir de la hotte avec une cosse connecteur de fils e Replacer le couvercle C ble d alimentation d nergie al Montage de la chemin e Chemin e d chappement sup rieure e largir l g rement les deux c t s de l vacuation sup rieure et les accrocher derri re les supports 7 3 et 7 2 1 en s assurant qu ils sont tous deux bien assis e Fixer les c t s aux supports avec les 4 vis 12c fournies S assurer que le raccord la sortie d air est en ligne avec les prises de chemin e Chemin e d chappement inf rieure e largir l g rement les deux c t s de l vacuation sup rieure et les accrocher entre la chemin e sup rieure et le mur en s assurant qu ils sont tous deux bien assis e Fixer la partie inf rieure lat ralement au corps de hotte en utili sant les 2 vis 12c fournies UTILISATION v2 L 5 Tableaux des commandes Lumi res Allume et teint l installation de l clairage S Del Del allumage Moteur V1 Moteur Met en marche et l arr t
24. und ing circuit could result in electrical shock e Check with a qualified electrician if you are in doubt as to whether the rangehood is prop erly grounded Failure to follow electrical requirements may result in a fire RECOMMENDATIONS AND SUGGESTIONS AThe Instructions for Use apply to several versions of this appliance Accord ingly you may find descriptions of individual features that do not apply to your specific appliance INSTALLATION The manufacturer will not be held liable for any damages resulting from incor rect or improper installation Check that the main voltage corresponds to that indicated on the rating plate fixed to the inside of the hood The electrical supply must be properly and sufficiently grounded Connect the extractor to the exhaust flue through a pipe of minimum diameter 6 The route of the flue must be as short as possible Do notconnect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc Ifthe extractor is used in conjunction with non electrical appliances e g gas buming appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The range hood has been designed exclusively for domestic use to eliminate kitchen odors Never use the hood fo
25. ws the final dimensions of the units For fixing at the top only proceed as follows Rest the back panel on the base inserting the lower plate between the upper surface and the wall centring it on the vertical reference line Mark the centres of the two holes in the upper plate Drill g 5 16 holes at all the centre points marked Insert the wall plugs 11 in the holes Fix the brackets using the 12a screws supplied Fix the back panel where present using the 12a screws supplied Mounting the hood body e Screw the two screws 12d supplied onto the brackets 7 1 e Hook the hood body onto the bracket 7 1 centring it around the vertical line Use the adjusting screws 12d underneath the hood to level the hood body Note The Hood body should be secured to wall studs If neces sary install a wood support behind the dry wall flush mounted between 2 studs This will provide the necessary structure and support for mounting Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using a rigid 6 duct e Install the damper 10 6 e Fix the duct in position using sufficient pipe clamps not sup plied DUCTLESS VERSION AIR OUTLET Put connection 15 into the connection support 7 3 Fix to the support using the 2 screws 12e supplied Connect the air outlet connection 15 to the hood body outlet using either a rigid 6 pipe not