1. 1 The custom wood hood must have a sturdy base 3 4 plywood recommended to accomodate the cut out for the Inca Pro 30 The base must be recessed to accomodate the height of the Liner see LINER DIMENSIONS on Page 4 The Liner attaches to the bottom of the base using screws appropriate for the size and material of your custom wood hood The Inca Pro 30 inserts into the cut out in the Liner and base 2 Position the rear section of the Liner so that it abuts the back edge of your custom wood hood Using a pen trace the outline of the pre cut out Remove the Liner and proceed to MAKE YOUR CUT OUTS on Page 6 Install both sections of the Liner and proceed to INSTALL THE RANGEHOOD on Page 7 Version 03 08 Page 5 ATTENTION This rangehood is designed to be connected to a remote blower pur chased separately CAUTION To reduce the risk of fire and electric shock install this rangehood only with remote blowers rated a maxi mum 1 8 Amp suitable for use with solid state fan speed controls The remote blower requires a separate wiring cable that should be installed at the same time that the ductwork is installed For best results 10 duct is recommended for the remote blower PLAN YOUR DUCTWORK To ensure that the blower performs to its highest possible capacity ductwork should be as short and straight as possilbe The ductrun should not exceed 55 equivalent feet if ducted using the required minimum of 10 round duct Cal
2. e 1 Literature Package PARTS NEEDED FOR INSTALLATION e 2 Conduit Connectors e Power Supply Cable e Screws to Reinforce Atttachment e Scews for Field Wiring Box e All Metal Ductwork WARNING When building a custom hood always follow all applicable codes and standards Inca Pro 30 can be used with custom hoods 30 wide and up Choose either a custom liner or our ProLiner designed for 36 wide installations Liners create a perfectly sealed non combustible finish for the underside of your custom wood hood The ProLiners are made up of two sections a larger rear section pre cut out for insertion of the Inca Pro 30 and a front section for a total adjustable depth between 21 and 25 Consider the shape size and weight of the Inca Pro 30 and Liner to determine the configuration of the custom wood hood See RANGEHOOD DIMENSIONS AND LINER DIMENSIONS on Page 4 RECOMMENDED ACCESSORIES AVAILABLE Remote Blower 900 CFM Blower part 630001732 1200 CFM Blower part 610000007 e Liners Create a perfectly sealed non combustible perimeter around the Inca Pro 30 Depth adjustable from 21 25 ProLiner 36 Stainless part 620000301 e Remote Wall Control Provides easy access at your finger tips to the rangehood light and speed controls by allowing you to install the control panel at another location of your choice part 620000542 FOR INSTALLATIONS WITH LINERS CUSTOM WOOD HOOD
3. Use a 1 1 4 Drill Bit to make this hole Install the cable Use caulking to seal around the hole DO NOT turn on the power until installation is complete 5 Make the cut out opening where the rangehood will be installed FIGURE 4 28 7 8 CUT OUT FIGURE 4 FIGURE 5 Version 03 08 Page 6 2 The entire bottom of the rangehood must be removed for installation as indicated in FIGURE 6 Remove the grease filters USING TWO HANDS one to hold the filter so that it doesn t fall on cooktop and one to turn the knob A in FIGURE 7 by pulling the knob out and turning to the left FIGURE 6 3 Remove the grease filter divider B in FIGURE 7 by first removing the plastic screw cover C in FIGURE 7 then removing the phillips screw under the screw cover FIGURE 7 4 Remove the two philips screws Din FIGURE 8 Remove the entire bottom of the rangehood by pushing your thumb into the side holes E in FIGURE 8 and pulling the sides free from the rangehood FIGURE 8 5 Fix the rangehood to the cabinet or custom hood using the four spring loaded brackets two on each side of the rangehood Using a philips screwdriver or drill tighten the adjustment screws F in FIGURE 9 until the brackets adhere tightly to the surface 6 IMPORTANT There are 6 holes G in FIGURE 9 for screws not provided to reinforce the rangehood to your cabinet or custom hood Use screws appropriate for the size and type of materials of you
4. cuisini re encastr e ou le dessus du comptoir pour prot ger des dommages et de la poussi re 2 D terminer et marquer clairement l aide d un crayon la ligne centrale sur le mur o la hotte sera install e 3 D terminer et faire toutes les coupes n cessaires dans le mur ou le plafond pour les conduits Installer les conduits avant la hotte 4 D terminer l emplacement appropri pour le c ble d alimentation Utiliser une m che de 1 1 4 po pour faire un trou et y passer le c ble d alimentation Utiliser du calfeutrage pour sceller tout autour du trou NE PAS mettre en circuit tant que l installation n est pas compl t e 5 D couper l ouverture o la hotte sera install e FIGURE 4 28 7 8 CUT OUT FIGURE 4 Version 03 08 Page 11 INSTALLATION DE LA HOTTE 1 Retirer l appareil de la bo te et le d poser FIGURE 5 sur une surface plate pour l assemblage Couvrir la surface pour viter tout dommage Retirer toutes les pi ces incluant les vis le registre clapet et le n ces saire de documentation avant de jeter la bo te 2 Retirer le bas de la hotte FIGURE 6 Retirerlesfiltres pour la graisse de l appareil et mettre de c t Lors de la l installation des filtres tirer faire tourner le bouton avec une main et tenir le filtre avec l autre main pour qu il ne tombe pas sur la table de cuisson Tirer le bouton A de la FIGURE7 vers l avant de la hotte en le tournant vers la g
5. Contours Cr ez un p rim tre parfaitement scell et sans danger autour du Inca Pro 30 Profondeur ajustable de 21 25 ProLiner 36 en Acier Inoxydable pi ce 620000301 e Panneau de contr les mural Vous procure l acc s du bout des doigts l clairage et aux contr les de vitesses en vous permettant d installer le panneau de contr le un autre endroit de votre choix pi ce 620000542 INSTALLATIONS AVEC CADRES HOTTE ENCASTRABLE DIMENSIONS DU CADRE la Neem page 4 1 La hotte encastrable doit avoir une base vigoureuse 3 4 contre plaqu recommand pour adapter au coupe circuit pour l Inca Pro 30 La base doit tre enfonc e pour adapter la taille du Cadre voir les DIMENSIONS DU CADRE la page 4 Les attaches de Cadre au fond de la base l aide des vis appropri es pour la hotte encastrable L Inca Pro 30 est install dans le coupe circuit dans le Cadre et la base 2 Placez la section arri re du Cadre de sorte qu il aboute le bord arri re de votre hotte encastrable En utilisant un stylo tracez le contour de la sortie pr coup e Enlevez le Cadre et proc dez FAIRE LA COUPE a la page 10 Installez les deux sections du Cadre et proc dez INSTALLATION DE LA HOTTE la page 11 Version 03 08 Page 10 ATTENTION Ceci est une hotte qui a t con ue pour tre branch e un ventilateur contr les ext rieurs tre command s par ment ATTENTION Pour r du
6. FABER INcAPRO30RB Power Pack e Installation Instructions e Use and Care Information READ AND SAVE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner The homeowner must keep these instruc tions for future reference and for local electrical inspec tors use READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium setting b Always turn hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UPA FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already
7. IAGRAMME DE C BLAGE Slide Switches pee hier ete ee mie WIRING BOX Sn ve a I QOD OY 120 Vac N TNT INCANDESCENT LAMPS LINE IN N M eCette hotte utilise des ampoules halog nes de 45 W Remplacement de la lumi re halog ne Avant de commencer s assurer que la hotte est hors circuit et que les autres ampoules ne sont pas chaudes Les ampoules halog nes sont extr mement chaudes lorsqu elles sont allum es et tout contact peut causer des blessures graves Pour remplacer l ampoule la bague autour de l ampoule doit tre retir e La bague est fix e par deux vis A de la FIGURE 11 Retirer les deux vis et la bague puis retirer l ampoule et la remplacer par une nouvelle ampoule D s que lampoule est en place replacer la bague FIGURE 11 Version 03 08 Page 13 FABER GARANTIE ET SERVICE CONOMISER POUR VOS ENREGISTREMENTS Faber garantit l utilisateur acheteur d origine que les produits Faber vendus neufs par nous sont sans vice de mat riel et de main d oeuvre d origine pour une p riode d un an a partir de la date d achat La garantie couvre la main d oeuvre et les pi ces de remplacement Afin d obtenir un service sous garantie communiquer avec le marchand ou la hotte a t achet e ou le distributeur Faber de la r gion Si l on ne peut trouver de distributeur Faber communiquer avec nous au 508 358 5353 afin d obtenir le nom d un distributeur dans la r gion Les fr
8. LLEZ PAS un fusible dans le circuit de mise terre ce qui peut causer une secousse lectrique e V rifiez avec un lectricien certifi ce que la hotte soit bien mise terre e Faute de suivre ces recommandations pourrait occasionner un feu Uniquement pour usage menager Version 03 08 Page 3 RANGEHOOD DIMENSIONS DIMENSIONS DE LA HOTTE A INCA PRO 30 LINER DIMENSIONS DIMENSIONS DU CADRE 84 35 7g ProLiner 36 Stainless 620000301 us designed for 36 wide installations ae Cadre Pro 36 Axier Inoxydable 620000301 peut tre employ e les hottes encastrable sur mesure de 36 Pre Planning Your Installation Important The recommended height to install this hood off the cooktop is a minimum of 30 for maximum effectiveness Also consult the cooktop manufacturer s recommendation Planifiez votre installation Important La hauteur recommand e pour installer cette hotte au dessus de la surface de cuisson est d un minimum de 30 pour un maximum d efficacit De plus nous vous recommandons consulter le manuel de recommandations du fabricant de la surface de cuisson Version 03 08 Page 4 TOOLS NEEDED FOR INSTALLATION e Saber Saw or Jig Saw e Drill e 1 1 4 Wood Drill Bit e Pliers e Phillips Screwdriver e Wire Stripper or Utility Knife e Metal Snips e Measuring Tape or Ruler e Level e Pencil e Caulking Gun e Duct Tape PARTS SUPPLIED FOR INSTALLATION
9. ais suivants ne sont pas couverts par la garantie Faber 1 Les appels de service pour corriger l installation de votre hotte de cuisini re pour vous indiquer comment utiliser votre hotte de cuisini re pour remplacer ou r parer les fusibles de votre maison ou pour corriger votre c blage ou votre syst me de plomberie 2 Les appels de service pour remplacer ou r parer les ampoules les fusibles ou les filtres de votre hotte de cuisini re 3 Les r parations lorsque votre hotte de cuisini re a t utilis e plus que la normale c est dire plus que pour une famille par foyer 4 Les dommages r sultant d un accident de l alt ration d une mal utilisation d un acte de Dieu d une installation inappropri e d une installation non conforme aux normes d lectricit ou de plomberie ou d une utilisation de l appareil non approuv e par Faber 5 Les pi ces de remplacement ou les frais de main d uvre pour les unit s utilis es en dehors du Canada ou des Etats Unis incluant toutes hotte de cuisini re approuv e par Faber non UL ou C UL 6 Les r parations dues des modifications non autoris es sur votre hotte de cuisini re 7 Les frais de transport de l appareil pour r parations distance Enregistrez Votre Information Ci dessous S quentiel Date d achat Version 03 08 Page 14
10. ake sure there is proper clearance within the wall or floor for exhaust duct before making cutouts Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed FOR MORE SPECIFIC DUCTWORK INFORMATION GO TO PAGE 6 WARNING To Reduce The Risk Of Fire Use Only Metal Ductwork Cold Weather installations An additional back draft damper should be installed to minimize backward cold air flow and a nonmetallic thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of the thermal break The break should be as close as possible to where the vent system enters the heated portion of the house A WARNING e To reduce the risk of fire and to properly exhaust air you MUST terminate ductwork outside of the home e DO NOT terminate the ductwork into spaces within the walls ceilings attics crawl spaces or garages e DO NOT use 4 laundry type wall caps e Flexible type ductwork is not recommended e DO NOT obstruct the flow of combustion and ventilation air e Failure to follow venting requirements may result in a fire ELECTRICAL REQUIREMENTS A 120 volt 60 Hz AC only electrical supply is required on a separate 15 amp fused circuit A time delay fuse or circuit breaker is recommended The fuse must be sized per local codes in accordance with the electrical rating of this u
11. auche Sens antihoraire pour d bloquer le levier de verrouillage FIGURE 6 3 Retirer le s parateur de les filtres pour la graisse B de la FIGURE 7 Retirer le couvercle plastique pour les vis C de la FIGURE 7 retirer le vis 4 Retirer les deux vis D in FIGURE 8 Retirer le bas de la hotte en pla ant votre pouce dans les trous E in FIGURE 8 et tirer le bas de la hotte FIGURE 8 FIGURE 9 5 Installer la hotte sur l armoire l aide de quatre fixations ressort deux de chaque c t de la hotte Utiliser un tournevis Phillips et serrer la vis de reglement F de la FIGURE 9 tandis que les fixations s attachent fortement la surface 6 IMPORTANT Installer la hotte sur l armoire l aide des 6 vis non inclues dans les trous G de la FIGURE 9 7 Si la t l commande de contr le optionnelle est utilis e veuillez consulter le feuillet d instructions inclus Apr s avoir suivi les in structions reportez vous a l tape 9 Si la t l commande n est pas utilis e vous reporter l tape 8 8 Retirer le couvercle dela bo te de c blage en enlevant les deux vis Voir FIGURE 10 pour informations Ins rer le c ble du ventilateur dans le trou de sortie de la hotte Ins rer le c ble d alimentation dans le trou de la hotte Brancher le c ble vert de mise la terre du syst me d alimentation la vis de mise laterre Brancher le c ble vert du v
12. culate the length of the ductwork by adding the equivalent feet in FIG URE 2 for each piece of duct inthe system An example is given in FIGURE 3 45 Elbow 3 0 feet 90 Elbow 5 0 feet 90 Flat Elbow 12 0 feet Wall Cap 0 0 feet FIGURE 2 9 Feet Straight Duct 9 0 feet 2 90 Elbows 10 0 feet Wall Cap 0 0 feet Total System 19 0 feet FIGURE 3 For best results use no more than three 90 elbows Make sure that there is a minimum of 24 of straight duct between elbows if more than one is used Do not install two elbows together If you must elbow right away do it as far away from the hood s exhaust opening as possible INSTALL THE RANGEHOOD 1 Remove the rangehood as seen in FIGURE 5 from the carton and place on a flat surface Cover the surface to prevent accidental damage Remove all parts including the literature package before discarding the carton MAKE YOUR CUT OUTS 1 Disconnect and move freestanding range from cabinet opening to provide easier access to upper cabinet or custom hood Put a thick protective covering over cooktop set in range or countertop to protect from damage or dirt 2 Determine and clearly mark with a pencil the center line on the cabinet or custom hood where the rangehood will be installed 3 Determine and make all necessary cuts in the wall and or ceiling for the ductwork Install the ductwork before the rangehood 4 Determine the proper location for the Power Supply Cable
13. eche bois 1 1 4 po e Pinces e Tournevis Phillips e D nude fil ou couteau tout usage e Pince coupante fil m tallique e Ruban mesurer ou r gle e Niveau e Crayon e Outil calfeutrage e Ruban a conduit PIECES FOURNIES POUR L INSTALLATION e 1 registre a clapet e 1 n cessaire de documentation PIN AVERTISSEMENT En constuisant une hotte encastrable sur commande suivez toujours tous les codes et normes applicables L Inca Pro 30 peut tre install e avec les hottes faites sur mesure 30 ou plus Pour des hottes encastrable choisissez un recouvrement fait sur commande ou notre Cadre Pro con u pour 36 installations Les Cadres cr ent une finition parfait scell e et non combustible pour le dessous de votre hotte encastrable Les Cadres Pro se composent de deux sections une plus grande arri re section et une section avant pour une profondeur r glable totale entre 21 et 25 Consid rez la forme la taille et le poids de linca Pro 30 et du Cadre determiner la configuration de la hotte encastrable Voir des DIMENSIONS DE LA HOTTE ET PI CES N CESSAIRES POUR L INSTALLATION e 2 connecteurs de conduit e Cable d alimentation e Conduit en m tal e Vis pout r inforcement e Vis pour compartiment de filage ACCESSOIRES RECOMMANDES DISPONIBLES Ventilateur contr les ext rieurs Ventilateur de 900 CFM pi ce 630001732 Ventilateur de 1200 CFM piece 61000007 e
14. ections with duct tape 11 Turn the power supply on Turn on the blower and light If the rangehood does not operate check that the circuit breaker is not tripped or the house fuse blown If the unit still does not operate disconnect the power supply and check that the wiring connections have been made properly remote blower conduit a twist on white wiring connectors violet wiring from blower Y G supply cable black wiring paar FIGURE 10 Version 03 08 Page 7 USE AND CARE INFORMATION This rangehood system is designed to remove smoke cooking vapors and odors from the cooktop area Rangehood Control Panel The control panel is located on the right hand side under the canopy The position and function of each control button are indicated in FIGURE 11 FIGURE 11 Light On Off Button L On Off switch for the halogen lights Move the switch to 1 to turn the light ON and to 0 to turn it OFF Blower On Off Button M On Off switch for the blower Move the switch to 1 to turn the blower ON and to 0 to turn it OFF Blower Speed Button V Variable Speed control for blower Move the switch from the left to the right LOW to HIGH speeds For Best Results Start the rangehood several minutes before cooking to develop proper airflow Allow the unit to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen Cleani
15. entilateur l autre vis verte de mise la terre Brancher le cable noir du moteur du ventilateur au c ble brun de la hotte et le fixer au moyen d un fil connecteur Ensuite connecter ensemble au moyen d un fil connecteur les c bles suivants C ble blanc du ventilateur et c blage du moteur C ble blanc de la hotte C ble violet de la hotte C ble d alimentation blanc 120 volts Brancher le c ble noir d alimentation au cable noir de la hotte avec un fil connecteur Replacer le couvercle de la bo te de c blage La fixer fermement avec la vis R installer le filtre Brancher l alimentation Le fil connecteur twist on est pr f rable pour brancher plusieurs fils de grosseurs diff rentes Conduit du entilateur Fil connecteur twist on C ble blanc INN Du ORZ lel I l contr le A RAVEL TANAN Jaune Vert Ventilateur Jaune Vert Cable d alimentation Cable noir Conduit de l alimentation FIGURE 10 9 Replacer le bas de la hotte et le s parateur de filtres pour la graisse et les filtres pour la graisse 10 Brancher le conduit sur le registre et sceller toutes les connexions avec du ruban conduit 11 Mettre l alimentation en circuit Mettre en circuit le ventilateur et la lumi re Si la hotte ne fonctionne pas v rifier si le disjoncteur n est pas ferm ou si le fusible n est pas grill Si l appareil ne fonctionne toujours pas d brancher l alime
16. ic gaskets or other materials DO NOT use for grounding e DO NOT ground to a gas pipe e DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in electrical shock e Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded e DO NOT use this appliance with any solid state fan speed control device e Failure to follow electrical requirements may result in a fire For residential use only Version 03 08 Page 2 REGLEMENTS D EVACUATION Confirmer la sortie d vacuation soit par le mur soit par le toit Utilisez une longueur de tuyauterie minimale avec les moindres de coudes pour la plus grande efficacite Le diametre de tuyauterie doit tre uniforme N installez jamais 2 coudes ensemble Scellez bien tous les joints avec un ruban adh sif m tallique l int rieur et scellez bien le clapet ext rieur avec du calfeutrage Utilisez un tuyau d vacuation rigide lorsque possible Un tuyau flexible gale deux fois plus qu un tuyau rigide ce qui r duit la puissance d vacuation Un conduit d vacuation flexible cr e une contre pression et une turbulence de l air qui r duisent consid rablement la performance Veillez ce que l espace pour le tuyau soit ample ainsi on n aurait pas besoin de d couper les supports de mur int rieur Si ce d coupage est n cessaire veillez bien ce qu un renforcement soit
17. ice panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For General Ventilating Use Only Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOL LOWING Installation Work And Electrical Wiring Must Be Done By Qualified Person s In Accordance With All Applicable Codes And Standards Including Fire Rated Construction Sufficient air is needed for proper combustion and exhaust ing of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors ATTENTION This hood can only be used with the Faber 900 or 1200 cfm variable speed blower part 630001732 or 610000007 A WARNING e Electrical ground is required on this rangehood e f cold water pipe is interrupted by plastic nonmetall
18. ire les risques d incendie et de chocs lec triques installer cette hotte seulement avec un ventilateur de 1 8 Am p res pr f rablement adapt des contr les de vitesses circuits int gr s Le ventilateur demande un c blage s par lequel devrait tre install au m me moment que les autres c bles Pour de meilleurs r sultats un conduit de 10 est recommand pour le ventilateur PLAN DU CONDUIT Pour assurer que le ventilateur marche le mieux le conduit doit tre aussi court et aussi droit que possible La longueur du conduit ne doit jamais exc der 55 pi s il s agit de conduit rond de 10 po Calculer la longueur du conduit en ajoutant l quivalent en pied de la FIGURE 2 pour chaque pi ce du conduit du syst me Un exemple est donn la FIGURE 3 3 0 feet 5 0 feet 12 0 feet 0 0 feet 45 Elbow 90 Elbow 90 Flat Elbow Wall Cap FIGURE 2 9 Feet Straight Duct 9 0 feet 10 0 feet 0 0 feet 19 0 feet 2 90 Elbows Wall Cap Total System FIGURE 3 Pour de meilleurs r sultats ne pas utiliser plus de trois coudes de 90 S assurer qu il y ait un minimum de 24 po de conduit droit entre les coudes si l on utilise plus d un coude Ne pas installer deux coudes ensemble FAIRE LA COUPE 1 D brancher et enlever la cuisini re afin d avoir un meilleur acc s aux armoires su p rieures et au mur arri re Placer un recouvrement pais sur la plaque de cuisson la
19. know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop This minimum clearance may be higher depending on local building code For example for gas ranges a minimum of 30 may be required The maximum depth of overhead cabinets is 13 Overhead cabinets on both sides of this unit must be a minimum of 18 above the cooking surface or countertop Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured Home Construction and Safety Standards Title 24 CFR Part 3280 formerly Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements LISEZ BIEN CETTE FICHE AVANT D INSTALLER LA HOTTE AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA TABLE DE CUISSON a Ne jamais laisser un l ment de la table de cuisson fonctionner sans surveillance a la puissance de chauffage maximale un renversement deborde ment de mati re graisseuse pourrait provoquer
20. mis en place R GLEMENTS D VACUATION ADDITIONELL PAGE 10 AVERTISSEMENT Pour Ne Pas Risquer Un Feu Utilisez Seulement Les Mat riaux M talliques Installations pour r gions climat froid On devrait installer un clapet antireflux additionnel pour minimiser le reflux d air froid et incorporer un l ment non m tallique d isolation thermique pour minimiser la conduction de chaleur par l interm diaire du conduit d vacuation de l int rieur de la maison l ext rieur Le clapet anti reflux doit tre place du c t air froid par rapport a l l ment d isolation thermique L isolant thermique doit tre aussi proche que possible de l endroit o le syst me d vacuation s introduit dans la partie chauff e de la maison L ATTENTION ce capot peut seulement tre utili s e avec le Faber 900 ou 1200 la pi ce variable 630001732 ou 610000007 de ventilateur de vitesse de cfm AVERTISSEMENT e Le syst me d vacuation DOIT sortir a l ext rieur e N EVACUEZ PAS le conduit soit dans une mansarde soit dans un espace enferm e N UTILISEZ PAS un clapet de s choir a 4 pouces e N utilisez pas un conduit flexible e N ENCOMBREZ PAS la circulation d air e Faute de suivre cet avertissement pourrait occasionner un feu FICHE TECHNIQUE LECTRIQUE Le raccordement lectrique doit se faire avec un circuit s par de 15 amperes fusible 120V 60 Hz courant alternant On recommande un coupe circuit La taille du f
21. ng The stainless steel grease filters should be cleaned frequently in hot detergent solution or washed in the dishwasher Clean exte rior surfaces with a commercially available stainless steel cleaner Abrasives and scouring agents can scratch stainless steel finishes and should not be used to clean finished surfaces WIRING DIAGRAM Slide Switches 0 min max O 1 O 1 WHT O O O O O O O 470 Ko WIRING BOX TEE Sa 120 Vac HALOGEN LAMPS LINE IN e This rangehood uses 45 watt Halogen Lamps Replacing the Halogen Lamp Before you begin make sure that the rangehood is turned off and that the other lamps have had sufficient time to cool Halogen lamps burn extremely hot and serious injury could result from touching a hot lamp Press and twist the lamp to remove If this is difficult for you you can remove the stainless bezel which is held in place by two screws A in FIGURE 12 Remove the two screws and the bezel Then remove the lamp and replace with a new lamp Once the new lamp is in place reinstall the bezel FIGURE 12 Version 03 08 Page 8 FABER WARRANTY amp SERVICE SAVE FOR YOUR RECORDS All Faber products are warranteed against any defect in materials or workmanship for the Original purchaser for a period of 1 year from the date of original purchase This warranty covers labor and replacement parts To obtain warranty service contact the dealer from
22. nit as specified on the serial rating plate located inside the unit near the field wiring compartment THIS UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordi nances Wire size and connections must conform with the rating of the appliance Copies of the standard listed above may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 This appliance should be connected directly to the fused disconnect or circuit breaker through flexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the appliance can be moved if servicing is ever neces sary A UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at the appliance and at the junction box When making the electrical connection cuta1 1 4 hole inthe wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOL LOWING Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at serv
23. ntation et v rifier si les connexions ont t effectu es correctement Version 03 08 Page 12 UTILISATION ET ENTRETIEN Cette hotte est con ue pour enlever la fum e les vapeurs de cuisson et les odeurs de la cuisine Panneau de commandes Le panneau de commandes est situ sur le c t droit sous la hotte La position et la fonction de chaque bouton sont indiqu es la FIGURE 10 FIGURE 10 Bouton marche arr t de la lumi re L Interrupteur marche arr t pour la lumi re R gler 1 pour mettre en circuit ON ou 0 pour mettre hors circuit OFF Bouton marche arr t du ventilateur M Interrupteur marche arr t pour le ventilateur R gler a 1 pour mettre en circuit ON ou 0 pour mettre hors circuit OFF Bouton de vitesse du ventilateur V R glage de la vitesse R gler a gauche pour vitesse basse LOW et a droite pour vitesse elevee HIGH Pour de meilleurs r sultats Mettre la hotte en circuit avant de commencer la cuisson Laisser l appareil fonctionner quelques minutes apr s la cuisson pour liminer la fum e et les odeurs Nettoyage Nettoyerr guli rementlesfiltres m talliques pour la graisse avec une solution d eau chaude et de d tergent ou mettre au lave vaisselle Nettoyer les surfaces ext rieures avec un d tergent pour l acier inoxydable Ne pas employer de produits abrasifs ou de poudre r curer qui endommagent les surfaces en acier inoxydable D
24. que affichez un avis de danger sur la porte AVERTISSEMENT POUR MINIMISER LE RISQUE DE CHOC LECTRIQUE Ce ventilateur doit tre install avec un mur d isolement iterrupteur de commande AVIS Pour L vacuation G n rale Veillez Ne Pas Evacuer Des Mat riaux Ou Vapeurs Explosif AVERTISSEMENT POUR MINIMISER LES RISQUES D INCENDIE CHOC ELECTRIQUE OU DOMMAGES CORPORELS OBSERVER LES PRESCRIPTIONS SUIVANTES L installation Et Le Raccordement Electrique Doivent Se Faire Par Un Technicien Qualifi Selon Tous Les Codes Municipaux Afin d obtenir un rendement maximal en ce qui a trait a la combustion ainsi qu l vacuation des gaz par la conduite de chemin e une bonne a ration est n cessaire pour tous les appareils combustion Suivez les conseils et mesures de s curit du fournisseur tels que ceux publi s par l Association Nationale de la Sauvegarde contre l incendie et l Association Am ricaine d Ing nieurs de Chauffage Frigorifaction et Air Climatis ainsi que les codes municipaux En per ant un mur veillez ne pas perforer un autre fil lectrique Une ventilateur vacuation ext rieure doit tre raccord e l ext rieur AVERTISSEMENT e Une prise terre est n cessaire pout cette hotte e N utilisez pas un tuyau l eau froide pour la mise terre s il est branch un joint plastique non m tallique ou autre e NE JOIGNEZ PAS la mise terre conduit de gaz e N INSTA
25. r cabinet or custom hood FIGURE 9 7 lf the optional remote wall control switch is being used please follow the instructions included with the remote wall switch pack age After following those instructions skip to step 9 below If the optional wall control switch is not being used continue to step 8 below 8 Remove the wiring box cover by removing the two screws See FIGURE 10 for reference Insert the cable of the remote blower into the knockout hole of the rangehood Insert the power supply cable into the hole of the rangehood Connect the green ground wire from the power supply to the ground screw Connect the green ground wire from the remote blower to the other green ground screw Con nect the black remote blower motor wire to the brown rangehood wire with a twist on wire connector Next connect together with a twist on wire connector the following wires white remote blower motor wire white rangehood wire violet rangehood wire 120 volt white supply wire Connect the black power supply wire to the black rangehood wire with a twist on connector Replace the wiring box cover Tighten the screw securely Reinstall the baffle filters Reconnect the power Twist on wire connectors should be suitable for connecting multiple wires of different sizes together 9 Replace the bottom of the rangehood and reinsert the grease filter divider and grease filters 10 Connect the ductwork to the rangehood and seal all conn
26. son Cette hauteur minimum peut tre plus haute suivant le code municipal Par exemple les cuisini res gaz peuvent requ rir 30 po de hauteur Les armoires au dessus ne d passeront pas 13 po de profondeur Les armoires au dessus de chaque c t devront tre au moins 18 po au dessus de la surface de cuisson Consultez la fiche technique avant de d couper les armoires L installation de cette hotte doit tre conforme aux R glements de Manufactured Home Construction and Safety Standards titre 24 CFR Section 3280 anciennement Federal Standard for Mobile Home Construction and Safety Standards titre 24 CFR Section 3280 anciennement Federal Standard for Mobile Home Construction and Safety titre 24 HUD Section 280 Le branchement lectrique se fait avec une raccordement a 4 fils Consultez la fiche technique lectrique Version 03 08 Page 1 VENTING REQUIREMENTS Determine which venting method is best for your application Ductwork can extend either through the wall or the roof The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance The size of the ductwork should be uniform Do not install two elbows together Use ducttape to seal all joints in the ductwork system Use caulking to seal exterior wall or floor opening around the cap Flexible ductwork is not recommended Flexible ductwork creates back pressure and air turbulence that greatly reduces performance M
27. une inflammation et le g n ration de fum e Utiliser toujours une puissance de chauffage moyenne ou basse pour le chauffage d huile b Veiller toujours faire fonctionner le ventilateur de la hotte lors d une cuisson avec une puissance de chauffage lev e ou lors de la cuisson d un mets flamber i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb c Nettoyer fr quemment les ventilateurs d extraction Veiller ne pas laisser de la graisse s accumuler sur les surfaces du ventilateur ou des filtres d Utiliser toujours un ustensile de taille appropri e Utiliser toujours un ustensile de taille adapt la taille de l l ment chauffant AVERTISSEMENT POUR PREVENIR LES BLESSURES EN CAS DE FEU SUIVRE LES RECOMMANDATIONS SUIVANTES ETOUFFEZ LE FEU avec un couvercle m tallique et fermez le br leur Si le feu ne s teint pas tout de suite QUITTEZ LES LIEUX ET APPELEZ LES POMPIERS NE TOUCHEZ JAMAIS UNE CASSEROLE EN FLAMMES N UTILISEZ JAMAIS DE L EAU ou un torchon mouill pour teindre le feu ce qui pourrait causer une explosion de vapeur N utilisez un extincteur que si 1 Vous avez un mod le ABC et vous connaissez bien son mode d emploi 2 Le feu est petit et peu r pandu 3 Les pompiers sont d j pr venus 4 Vous avez une sortie derri re vous TOUTE OUVERTURE DANS LE MUR OU LE PLANCHER PROXIMIT DE LA HOTTE DOIT TRE SCELLE Gardez 24 po de hauteur entre le bas de la hotte et la surface de cuis
28. usible doit se conformer aux codes municipaux suivant la sp cification lectrique sur la plaqueint rieure Le diam tre du fil devra aussi se conformer aux r glements du code national lectrique ANSI NFPA 70 ainsi qu aux r glements locaux et les sp cifications de cet appareil On peut obtenir ces informations chez l Association Nationale de la Pr vention du Feu Batterymarch Park Quincy Massachusetts 02269 Raccordez cet appareil directement au coupe circuit avec unfil flexiblle couvert en cuivre en laissant un peu de l chement dans le fil pour permettre le d placement de l appareil Veillez a ce qu un contact d un demi pouce 1 2 po soit install chaque bout de fil soit l appareil ainsi qu la boite fusible Faites un trou de 1 1 4 po dans le mur S il s agit d un trou en bois sablez le bien tandis qu un trou passant par le m tal demande un bouche trou AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE OU DE CHOC ELECTRIQUE ne pas utiliser ce ventilateur en conjonction avec un dispositif de r glage de vitesse semi conducteurs AVERTISSEMENT POUR MINIMISER LES RISQUES D INCENDIE CHOC ELECTRIQUE OU DOMMAGES CORPORELS OBSERVER LES PRESCRIPTIONS SUIVANTES Suivez les recommandations du fabricant et entre en communication avec lui pour toute information Fermez le courant avant tout entretien et veillez a ce qu il reste ferm Si on ne peut pas verrouiller le panneaux du service lectri
29. whom you purchased the rangehood or the local Faber distributor If you cannot identify a local Faber distributor contact us at 508 358 5353 for the name of a distributor in your area The Following is not covered by Faber s warranty 1 Service calls to correct the installation of your range hood to instruct you how to use your range hood to replace or repair house fuses or to correct house wiring or plumbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than normal single family household use 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or use of products not approved by Faber 5 Replacement parts or repair labor costs for units operated outside the United States or Canada including any non UL or C UL approved Faber rangehoods 6 Repairs to the hood resulting from unauthorized modifications made to the rangehood 7 Expenses for travel and transportation for product service in remote locations and pickup and delivery charges Faber range hoods should be serviced in the home Record Your Information Below Serial Date of Purchase Version 03 08 Page 9 OUTILS N CESSAIRES L INSTALLATION e Scie sauteuse ou d couper e Perceuse e M

Download Pdf Manuals

image

Related Search

Related Contents

Glacier Bay 20064-2204 Installation Guide  Katalog TS 2012.indd  BENDIX 03-L-5 User's Manual  竄轟K ヘッドレストー寸コンフォ一トフロント子供のせ 取  Manual de Instalación de cliente SIAP  Curtis LCD2424A Flat Panel Television User Manual    Sylvania SDPF733 Digital Photo Frame User Manual  Descargar ficha técnica  Greenlee NC-500 cable network tester  

Copyright © All rights reserved.
Failed to retrieve file