Home

Ericsson SP4900HDR Printer User Manual

image

Contents

1. EAcali DIGITAL COUNTING SCALE M Series OPERATING MANUAL INTRODUCTION Congratulations on your purchase of our Multifunctional Scale In order to ensure the scale continues to deliver peak performance please read these operation instructions carefully and thoroughly prior to initial usage IMPORTANT ol gt Se N ol Read all instructions before operating the scale Follow the basic safety precautions for all office equipment when using this scale The manufacturer does not warrant this unit to be waterproof Do not expose this product to rain or moisture Do not use the scale in direct sunlight Keep it away from heating appliances such as an oven stove etc This scale does not contain any user serviceable parts Do not disassemble Use the scale for its intended purpose only Note The display value may be affected by electromagnetic influences e g when a radio is operated in the immediate vicinity of the device The product can be used for its intended purpose again when the interference is discontinued but may need to be switched on again to re start BATTERY INSTALLATION 1 Turn the entire scale upside down and reset it securely on a firm flat surface 2 Open the battery door by loosing the battery door screw 3 Install four UM2 size C batteries in the battery compartment ensuring that the positive negative side is in the direction as shown in the cabinet 4 Close the ba
2. ENANCE Clean with a soft cloth Do not immerse directly into water or detergent scrub with abrasive material or use corrosive cleanser TECHNICAL SPECIFICATIONS M63 M136 M3315 M6630 Maximum Capacity 3kg 6lb 6kg 13lb 15kg 33lb 30kg 66lb Graduation 0 5g 0 10z 1g 0 102 5g 0 20z 5g 0 202 Sample size 10 20 40 60 80 100 pcs Operating Temperature 0 C 40 C Power Source 4 UM2 size C 1 5V battery or 9 0V 300mA AC DC adaptor optional Accuracy 0 2 Dillon Quality Plus Inc 3501 N E Kimball Dr Kansas City MO 64161 Phone 800 493 2263 Phone 816 453 7600 FAX 816 453 7677
3. ading when you remove all items Press the Tare key once and the negative reading will disappear USING THE COUNTING MODE A Set sample size Turn on the scale Press PCS key SET will be shown on the display Press MODE key 100 will be displayed Press MODE key again to select the sample size in the sequence of 10 20 40 60 80 100 Press PCS key to confirm the sample size pcs icon will be shown on the left hand corner of the display 6 Press PCS again to return to weighing mode a AIRON E Remark the sample weight is memorized in the scale You only need to repeat steps 2 4 and 5 for different objects or sample size B COUNTING 1 Turn on the scale 2 Place the samples on the platform 3 Press the PCS key the sample size as set by the above setting steps will be displayed 4 Place objects on the platform the scale will calculate and shown the numbers on the LCD Remark by pressing the TARE key will activate the accumulation of counting See Tare Mode steps OVERLOAD When the loading capacity exceeds the maximum capacity of the Digital Scale the word EEEEE will be displayed on the LCD screen Remove the item s from the scale platform to avoid damage to the scale POWER OFF 1 The scale can be powered off manually by pressing the On Off key 2 The scale will be totally shut down by pressing the power switch MAINT
4. een will show all characters for a few seconds and then 0 000 will be shown on the display 3 The scale turns off automatically after being idle for two minutes EL BACK LIGHT Your can turn On or Off the Back light of the scale by pressing the Back Light key WEIGHING AN ITEM 1 Turn on the scale 2 Place an item on the platform and the exact weight of item will be displayed SELECTING WEIGHT UNIT When the scale is power on press the MODE key repeatedly to change weight unit according to following sequence kg Ib oz lb oz Displays 4 modes e g kg mode T 1 500kg Ib mode L 3 32lb oz mode O 52 90z Ib oz mode O 3lb 4 90z USING THE HOLD FUNCTION When the object is on the scale platform press the HOLD key once and then take off the object from the scale platform the weight of the object will be hold for 1 minute with a HOLD icon displays on the left side of the LCD USING THE TARE MODE Turn the scale on 0 000 gt will be shown on the display after a few seconds Place an item on the weighing platform and read the value accordingly Press the TARE key the weight of this item will be eliminated and the reading will change to 0 000 Place next item on the weighing platform and get the reading Press TARE key again will show the total weight Repeat step 4 to 6 for further objects eS ALOY OJ Note The scale will display a negative re
5. ttery door and fasten it with the screw BATTERY STATUS e When the battery is low Lo will be displayed Open the battery compartment and replace the old batteries with new ones e Used batteries must not be disposed of as household waste Do not incinerate batteries because they might explode at high temperature Contact your local authority for information concerning reclamation and disposal of batteries e When replacing batteries always use brand new batteries of the same type AC DC ADAPTOR Optional 1 Open the Adaptor cabinet door 2 Plug the adaptor jack into the socket 3 Take out the adaptor and close the cabinet door 4 Plug the adaptor to the AC main PART AND KEY DESCRIPTION 8 9 AC DC Adaptor AC DC adaptor Socket 7 Adaptor Doar 1 Stainless Steel Platform 2 Bubble Leveler 3 Liquid Crystal Display LCD 4 Keypad 5 Battery Door and Compartment 6 Main power On off Switch ie 7 Adaptor door On Off Switch 8 AC DC adaptor socket 9 AC DC adaptor optional 6 10 Level adjusting feet 1 Stainless Steel Battery Door and Compartment OPERATION LEVEL THE SCALE When the scale is put to use at a new place adjust the level of the scale by turning the 4 level adjusting feet until the bubble is located in the middle position of the bubble leveler poe THE SCALE Turn on the power on off switch 5 Turn the scale on by pressing ON OFF key 2 The LCD scr

Download Pdf Manuals

image

Related Search

Related Contents

EUROLITE PAR-64 Spot w/cable & plug User Manual  Programador de riego FBC 7 A1 Computer per irrigazione    SoftBank 304ZT ユーザーガイド - 取扱説明書  TAFCO WINDOWS NU2-283S-I Instructions / Assembly  尾くじ  静電気除去ミニファン 取扱説明書  Manuel d`installation et d`entretien - Co  Sony LCM-CSVH Notes  Pression pneus.cdr  

Copyright © All rights reserved.
Failed to retrieve file