Emerson XMT-P-FF/FI Satellite Radio User Manual
Contents
1. 3 Keep the transmitter and sensor wiring at least one foot from high voltage conductors Be sure there is easy access to the transmitter 4 The transmitter is suitable for panel Figure 3 pipe Figure 4 or surface Figure 5 mounting duit openings and either one or four 1 2 inch knock outs The panel mount Xmt P FF F has four knock outs The pipe surface mount transmitter has two knockouts One conduit opening is for the power out put cable the other opening is for the sensor cable 9 The transmitter case has two 1 2 inch PG13 5 con Figure 1 shows how to remove a knockout The knockout grooves are on the outside of the case Place the screwdriver blade on the inside of the case and align it approximately along the groove Rap the screwdriver sharply with a hammer until the groove RENE TE cracks Move the screwdriver to an uncracked portion NEEDED GROUNDED CONNECTOR of the groove and continue the process until the TAL Steen knockout falls out Use a small knife to remove the PROVIDED WITH i TRANSMITTER POWER SUPPLY flash from the inside of the hole 9 32 VDC O 6 Use weathertight cable glands to keep moisture out to the transmitter If conduit is used plug and seal the connections at the transmitter housing to prevent moisture from getting inside the instrument
2. 7 To reduce the likelihood of stress on wiring connec tions do not remove the hinged front panel 11 mod els from the base during wiring installation Allow FIGURE 2 Power Supply Current Loop Wiring sufficient wire leads to avoid stress on conductors NEMA plug may be supplied instead of knockout for pipe surface version MODEL Xmt P INSTALLATION Panel Mounting 69 9 MILLIMETER lt lt INCH gt 21 41 5 ee KNOCKOUT 845 PLACES MN TN ELECTRICAL CONDUIT OPENINGS 41 7 CT PNE 6 PLACES F OR 2 INCH CONDUIT FITTINGS OR 13 5 CABLE ____ d GLANDS 94 5 4 4 y5 REF ae PANEL SUPPLIED BY OTHERS Aee a MAXIMUM THICKNESS 2575 IN 9 52 mq MEN aa gt rere TOP VIEW E MOUNTING BRACKET AND SCREW 4 PROVIDED WITH INSTRUMENT OO MAX RADIUS 4 PLACES PANEL CUT OUT 4 DO NOT OPERATE OR ENERGIZE INSTRUMENT WITH CASE OPEN FIGURE 3 Panel Mount Installation Access to the wiring terminals is through the rear cover Four screws hold the cover in place MODEL Xmt P INSTALLATION Pipe Mounting MILLIMETER INCH e Ul BOBEMOUNTTANALVECAE FRONT VIEW SCREW COVER 4 PLACES 2 PIPE SUPPLIED BY FRONT CUSTOMER ENCLOSURE KNOCKOUT 2 PLACES GASKET REAR ENCLOSURE KNOCKOUT BRACKET 2 INCH PIPE MOUNT Emp BUS IN KIF PN 238 FOR
3. 2 INCH PIPE 20 00 AX DO NOT OPERATE OR ENERGIZE INSTRUMENT WITH CASE OPEN VERTICAL PIPE MOUNTING SHOWN TQ HORIZONTAL PIPE ROTATE BRACKET AND U BOLTS 90 FIGURE 4 Pipe Mount Installation The front panel is hinged at the bottom The panel swings down for access to the wiring terminals MODEL Xmt P INSTALLATION Surface Mounting WALL BY OTHERS MILLIMETER INCH MOUNTING BOSS 4 PLACES SELF LAPPING SCRENS NUMBER 6 WITH O RING PLACES SUPPLIED WITH INSTRUMENT ROSEMOLNT ANALYTICA KNOCKOUT 2 PLACES WALL SCREW COVER 4 PLACES 63 85 FRONT 2 150 ENCLOSURE 21 41 24 03 843 1 3715 GASKET 2 Ul OP GS REAR gt AAA AAAA AEREE WALL KNDCKOUT BOTTOM VIEW DRILL FOR NUMBER 6 SELF TAPPING SCREWS 4 PLACES DO NOT OPERATE OR ENERGIZE INSTRUMENT WITH CASE OPEN PIERCE MEMBRANE WITH SELF TAPPING SCREW HOLE PATTERN FOR REAR SURFACE MOUNT ENCLOSURE FIGURE 5 Surface Mount Installation The front panel is hinged at the bottom The panel swings down for access to the wiring terminals MODEL Xmt P INSTALLATION 23894 7 REVO a gt 0 unu n pH ORP 5V CHLORINE OXYGEN OZONE 18 pH ORP IN pH ORP GUARD 6 SOLUTION GROUND REFERENCE REFERENCE GUARD RTD IN TB2 RTD SENSE GROUND RTD RETURN 4 20mA FF 4 20mA FF 9241581 00 FIGU
4. not call 1 800 854 8257 or 949 757 8500 to request correct manual For clarification of instructions contact your Rosemount representative Follow all warnings cautions and instructions marked on and supplied with the product Use only qualified personnel to install operate update program and maintain the product Educate your personnel in the proper installation operation and maintenance of the product Install equipment as specified in the Installation section of this manual Follow appropriate local and national codes Only connect the product to electrical and pressure sources specified in this manual Use only factory documented components for repair Tampering or unauthorized substitution of parts and procedures can affect the performance and cause unsafe operation of your process All equipment doors must be closed and protective covers must be in place unless qualified personnel are performing maintenance If this equipment is used in a manner not specified by the manufacturer the protection provided by it against hazards may be impaired WARNING EXPLOSION HAZARD DO NOT OPEN WHILE CIRCUIT IS LIVE DO NOT RUB OR CLEAN WITH SOLVENTS 9241589 00 A ROSEMOUNT Analytical EMERSON MODEL Xmt P SPECIFICATIONS GENERAL Case ABS panel mount polycarbonate pipe surface mount Both versions are NEMA 4X CSA 4 IP65 Dimensions Panel code 10 6 10 x 6 10 x 3 72 in 155 x 155 x 94 5 mm Surfa
5. Instruction Sheet PN 51A Xmt P FF Fl rev A January 2006 Model Solu Comp Xmt P FF F FOUNDATION Fieldbus Two Wire pH ORP Transmitter For additional information please refer to the Instruction Manuals CD shipped with this product or visit our website at www emersonprocess com rathome liquid ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING Your purchase from Rosemount Analytical Inc has resulted in one of the finest instruments available for your particular application These instruments have been designed and tested to meet many national and interna tional standards Experience indicates that its performance is directly related to the quality of the installation and knowledge of the user in operating and maintaining the instrument To ensure their continued operation to the design specifications personnel should read this manual thoroughly before proceeding with installation commissioning operation and maintenance of this instrument If this equipment is used in a manner not speci fied by the manufacturer the protection provided by it against hazards may be impaired Failure to follow the proper instructions may cause any one of the following situations to occur Loss of life personal injury property damage damage to this instrument and warranty invalidation Ensure that you have received the correct model and options from your purchase order Verify that this man ual covers your model and options If
6. RE 6 Loop Power and Sensor Wiring Panel Mount 10 000 c Lal c 1 2 z IH Jaa L pesez ASSY 2 4 20mA FF 4 20 GROUND X SE SOLUTION GROUND 6 pH ORP GUARD pH ORP pH ORP IN CHLORINE GXYGEN OZONE 5 19 5v Hol NOT USED FOR pH ORP ANODE NOT USED FOR pH ORP CATHODE 9241587 01 FIGURE 7 Loop Power and Sensor Wiring Pipe Surface Mount uBiu UIU MO UJEM 4 JazAjeuy sjuiodies jehusjodos Hd sinden soBessaw 0192 JOSUSS ELLA sonsoubeid pu 55216 XOp8M dMO dwong dwal 3443 enuen E J9jul 9zi iqeis 92114015 NIVIN YSALLINSNVYL ld dd d WX dINOD 1 1 9 3341 11 Jang 20 ezipiepue
7. ce Pipe code 11 6 23 x 6 23 x 3 23 in 158 x 158 x 82 mm see page 5 for dimensions of pipe mounting bracket Conduit openings Accepts PG13 5 or 1 2 in conduit fit tings Ambient Temperature 32 to 122 F 0 to 50 C Some degradation of display above 50 C Storage Temperature 4 to 158 F 20 to 70 C Relative Humidity 10 to 90 non condensing Weight Shipping Weight 2 15 3 Ib 1 kg 1 5 kg Display Two line 16 character display Character height 4 8 mm first line shows process variable pH ORP conductivity concentration oxygen ozone chlo rine monochloramine second line shows process temperature and output current For pH chlorine com bination pH may also be displayed Fault and warn ing messages when triggered alternate with temper ature and output readings During calibration and programming messages prompts and editable values appear on the two line display Temperature resolution 0 1 C lt 99 9 C 1 C gt 100 Hazardous Location Approval For details see specifi cations for the measurement of interest RFI EMI 61326 C Digital Communications For details see specifications for the measurement of interest Power amp Load Requirements A power supply voltage of 9 32 Vdc at 13 mA is required FUNCTIONAL SPECIFICATIONS pH Range 010 14 ORP Range 1400 to 1400mV Calibrations standardization The automatic buffer recognition uses stored buffer values a
8. js The right people the right answers 5 lt right now ROSEMOUNT ANALYTICAL CUSTOMER SUPPORT CENTER 1 800 854 8257 Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine CA 92606 USA Tel 949 757 8500 Fax 949 474 7250 http www raihome com Rosemount Analytical Inc 2006 ON LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http www raihome com Specifications subject to change without notice 575 a Credit Cards for U S Purchases Only 9 ied eS 150 6 b amp Qu EMERSON pm cde p rneaocc l 2cmnmaaaman rrocess iViahnagement pe
9. nd their tempera ture curves for the most common buffer standards avail able worldwide The transmitter also performs a stabilization check on the sensor in each buffer SPECIFICATIONS A manual two point calibration is made by immersing the sensor in two different buffer solutions and entering the pH values The microprocessor automatically calculates the slope which is used for self diagnostics An error message will be displayed if the pH sensor is faulty This slope can be read on the display and or manually adjusted if desired An on line one point process standardization is accom plished by entering the pH or ORP value of a grab sample Preamplifier Location A preamplifier must be used to convert the high impedance pH electrode signal to a low impedance signal for transmitter use The integral pream plifier of the Model Xmt P may be used when the sensor to transmitter distance is less than 15 ft 4 5 m Locate the preamplifier in the sensor or junction box for longer distances Automatic Temperature Compensation External 3 or 4 wire Pt 100 RTD or Pt 1000 RTD located in the sensor compensates the pH reading for temperature fluctuations Compensation covers the range 15 to 130 C 5 to 270 F Manual temperature compensation is also selectable Accuracy 1 mV 25 C 0 01 pH Repeatability 1 mV 25 C 0 01 pH Stability 0 25 year 25 C Diagnostics The internal diagnostics can detect Calibration Error Sens
10. or Failure High Temperature Warning CPU Failure Low Temperature Warning Input Warning ROM Failure Glass Warning Glass Failure Reference Failure Reference Warning Once one of the above is diagnosed the display will show a message describing the problem Digital Communications Fieldbus pH Four Al blocks assigned to pH tem perature reference impedance and glass imped ance Fieldbus ORP Three Al blocks assigned to ORP temperature and reference impedance Fieldbus pH and ORP Execution time 75 msec One PID block execution time 150 msec Device type 4085 Device revision 1 Certified to ITK 4 5 MODEL Xmt P SPECIFICATIONS SENSOR COMPATIBILITY CHART TF396 none QUICK START GUIDE FOR MODEL SOLU COMP Xmt P FF FI TRANSMITTER 1 Refer to page 5 for installation instructions 2 Wire pH or ORP sensor to the transmitter See Figure 6 for panel mount Figure 7 for pipe or surface mount Refer to the sensor instruction sheet for details Once connections are secure and verified apply power to the transmitter When the transmitter is powered up for the first time Quick Start screens appear Using Quick Start is easy a A blinking field shows the position of the cursor b Use or gt key to move the cursor left or right Use the or 4 key to move the cursor up or down to increase or decrease the value of a digit Use the or key to move the decimal point c Press ENTER to store a set
11. ting Press EXIT to leave without storing changes Pressing EXIT also returns the display to the previous screen Measure 5 Choose measurement pH ORP or Redox Use in 6 Choose preamplifier location Select Xmtr to use the integral preamplifier in the transmitter select Sensor JBox if your sensor has an integral preamplifier or if you are using a remote preamplifier located in a junction box Temperature in 7 Choose temperature units C or F 8 change output settings to scale the 4 20 mA output to change measure ment related settings from the default values and to set security codes press MENU Select Program and follow the prompts Refer to the appropriate menu tree page 11 9 To return the transmitter to default settings choose ResetAnalyzer in the Program menu MODEL Xmt P INSTALLATION UNPACKING AND INSPECTION Inspect the shipping container If it is damaged contact the shipper immediately for instructions Save the box If there is no apparent damage unpack the container Be sure all items shown on the packing list are present If items are missing notify Emerson Process Management immediately INSTALLATION 1 Although the transmitter is suitable for outdoor use do not install it in direct sunlight or in areas of extreme temperatures 2 Install the transmitter in an area where vibrations and electromagnetic and radio frequency interference are minimized or absent