1. replace light bulbs Long life bulbs are recommended to reduce the frequency of bulb changes To access the light bulb area BF33STP BF39STP models 1 Open steel curtain remove glass doors if applicable 2 Remove two screws on log bracket and set aside FIGURE 3 3 Pull front edge of plastic ember bed or plastic grate up and forward until rear tab releases from the ledge located at the bottom of the mirror FIGURE 4 Note Log set fits tightly into firebox some force may be necessary to remove Ne 4 Examine the bulbs to determine which bulbs pe S require replacement som SS 5 Unscrew bulbs counter clockwise a 6 Insert new bulbs FIGURE 3 7 Replace the log by inserting the rear tab of the logset under the back ledge of the fireplace and push down on the front edge of the logset until it snaps into place FIGURE 4 8 Replace log grate using two screws previously removed LOG EMBERBED SIDE SECTION FIGURE 4 To access the light bulb area BF33DXP BF39DXP models 1 Open steel curtain remove glass doors if applicable 2 Remove two screws on log bracket and set aside FIGURE 3 3 Pull front edge of plastic ember bed or plastic grate up and forward until rear tab releases from the ledge located at the bottom of the mirror FIGURE 4 Note Log set fits tightly into firebox some force may be necessary to remove 4 Set logset in
2. may cause an electric shock or fire or damage to the heater To prevent a possible fire do not block air intake or exhaust in any manner All electrical heaters have hot and arcing or sparking parts inside Do not use in areas where gasoline paint or flammable liquids are used or stored or where the unit will be exposed to flammable vapors Do not modify this fireplace Use it only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 10 Do not burn wood or other materials in this fireplace 11 Do not strike fireplace glass 12 Always use a certified electrician for installation 13 Disconnect all power coming to fireplace at main service panel before performing any cleaning or maintenance 14 When transporting or storing the fireplace keep in a dry place free from excessive vibration and store as to avoid damage NOTE Procedures and techniques that are considered important enough to emphasize CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose he user to the risk of fire serious injury illness or death IMPORTANT INSTRUCTIONS If you have any questions about our products please have the product model and serial numbers available upon calling Dimplex customer service To locate the model and serial number
3. FIGURE 6 Mirror Cleaning The mirror is cleaned in the factory during the Assembly operation During shipment installation Handling etc the mirror surface may collect dust Particles these can be removed by buffing lightly With a clean dry cloth To remove fingerprints or other marks the mirror can be cleaned with a damp cloth using good quality household glass cleaner The mirror should be completely dried with a lint free cloth to prevent water spots To prevent scratching do not use abrasive cleaners or spray liquids on the clear door surface ACCESSORIES Please contact your local dealer for genuine Dimplex accessories Example Glass door kits brass and stainless steel trims remote control kits plug kits and cabinets designed to fit your fireplace TWO YEAR LIMITED WARRANTY Products to which this limited warranty applies This limited warranty applies to the following models of your newly purchased Dimplex electric fireplace BF33STP BF33DXP BF39STP BF39DXP and to newly purchased Dimplex fireplace surrounds mantels and trims This limited warranty applies only to purchases made in any province of Canada except for Yukon Territory Nunavut or Northwest Territories or in any of the 50 States of the USA and the District of Columbia except for Hawaii and Alaska This limited warranty applies to the original purchaser of the product only and is not transferable Products excluded from this limited warranty
4. Light bulbs are not covered by this limited warranty and are the sole responsibility of the owner purchaser Products purchased in Yukon Territory Nunavut Northwest Territories Hawaii or Alaska are not covered by this limited warranty Products purchased in these States provinces or territories are sold AS IS without warranty or condition of any kind including without limitation any implied warranties or conditions of merchantability or fitness for a particular purpose and the entire risk of as to the quality and performance of the products is with the purchaser and in the event of a defect the purchaser assumes the entire cost of all necessary servicing or repair What this limited warranty covers and for how long Products other than fireplace surrounds mantels and trims covered by this limited warranty have been tested and inspected prior to shipment and subject to the provisions of this warranty Dimplex warrants such products to be free from defects in material and workmanship for a period of 2 years from the date of the first purchase of such products Dimplex fireplace surrounds mantels and trims covered by this limited warranty have been tested and inspected prior to shipment and subject to the provisions of this warranty Dimplex warrants such products to be free from defects in material and workmanship for a period of 1 year from the date of first purchase of such products The limited 2 year warranty period for products ot
5. STS OR DAMAGES THAT EXCEED THE PURCHASE PRICE OF THE PRODUCT SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE PURCHASER How State and Provincial law apply This limited warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction The provisions of the United Nations Convention on Contracts for the Sale of Goods shall not apply to this limited warranty or the sale of products covered by this limited warranty 1 888 DIMPLEX SC Dimplex 1 888 346 7539 C US 1367 Industrial Road Cambridge Ontario Canada N1R 7G8 Approved for use in the United States and Canada
6. X Dimplex PRACTICAL USER S GUIDE FOR THE ELECTRIC FIREPLACE MODEL NUMBERS BF33STP DXP BF39STP DXP Write Your Remote Quality checked by Control Code Number Here Valued Customer We are pleased that you have chosen to purchase an electric fireplace manufactured by Dimplex North America Ltd Over the years valuable memories will occur around the warmth and comfort of your hearth Thank you for allowing our product to be the backdrop for those special moments 7206360300REV01 QUICK REFERENCE GUIDE FOR THE ELECTRIC FIREPLACE 1 Prior to the first use of the fireplace verify the following e Are the circuit breakers for the fireplace on e Are the light bulbs in your fireplace loose to check follow the instructions for replacing the light bulbs under the maintenance section of this manual The heater on your fireplace may emit a slight harmless odor when first used This odor is a normal condition caused by the initial heating of internal heater parts and will not occur again If your heater does not emit heat ensure the large switch is on the wall thermostat is set above the current room temperature and any wall switches for the unit are on If this does not work switch the unit off for 5 minutes and try again Consult operation section of your practical users guide for further information The information regarding the model of your fireplace can be found on the rating plate located under the logs i
7. anty period for surrounds mantels and trims you have the following rights Dimplex will in its sole discretion either repair or replace such defective product or part without charge If Dimplex is unable to repair or replace such product or part or if repair or replacement is not commercially practicable or cannot be timely made Dimplex may in lieu of repair or replacement choose to refund the purchase price for such product or part Limited warranty service will be performed solely by dealers or service agents of Dimplex authorized to provide limited warranty services For products other than surrounds mantels and trims this 2 year limited warranty entitles the purchaser to on site or in home warranty services Accordingly Dimplex will be responsible for all labour and transportation associated with repairing or replacing the product or part except as follows i charges which may be levied for travel costs incurred to travel to the purchaser s site where the product is located if the purchaser s site is beyond 30 miles 48 km from the closest service depot of Dimplex s dealer or service agent and ii the purchaser is solely responsible for providing clear access to all serviceable parts of the product For surrounds mantels and trims this 1 year limited warranty does not entitle the purchaser to on site or in house warranty services The purchaser is responsible for removal and transportation of the surrounds mantels and tr
8. e heater continuously resets disconnect the power at the main service panel and call your local dealer NOTE The heater may emit a slight harmless odor when first used This odor is a normal condition caused by initial heating of internal heater parts and will not occur again MAINTENANCE WARNING Disconnect all power coming to fireplace at main service panel before attempting maintenance or cleaning to reduce risk of fire shock or damage to persons NOTE Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental burning of skin TOOL REQUIREMENTS Slot screwdriver LIGHT BULB REPLACEMENT Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental burning of skin Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log exterior disappears There are four bulbs under the log set which generate the flames and embers LIGHT BULB REQUIREMENTS Quantity of 4 clear chandelier or candelabra bulbs with an E 12 small socket base 60 watt rating Example GE 60BC or Philips 60CTC DO NOT EXCEED 60 WATTS PER BULB CAUTION When handling log only apply force to the ember bed section not directly to the logs HELPFUL HINTS It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life Group replacement will reduce the number of times you need to open the unit to
9. front of firebox Disconnect the logset LED wire harness from unit FIGURE 5 Examine the bulbs to determine which bulbs require replacement Unscrew bulbs counter clockwise Insert new bulbs Re connect the logset LED wire harness to the unit 10 Replace the log by inserting the rear tab of the logset under the back ledge of the fireplace and push down on the front edge of the logset until it snaps into place FIGURE 4 11 Replace log grate using two screws previously removed PURIFIRE FILTER The Purifire filter supplied in your fireplace is reusable and washable The filter should be cleaned or replaced on average once a year or if overheat indicator lamp is activated To clean the filter gently tap filter on a hard surface to dislodge any loose dirt or debris and then clean with water No soap or cleaning products are recommended The filter size is 20 X 10 X 1 rated at MERV 10 If using an after market filter follow the manufacturers recommended replacement instructions To replace filter 1 Remove the 2 mounting screws from the air filter bracket 2 Slide forward to remove the air filter bracket assembly from the firebox 3 Slide filter out of air filter bracket 4 Reassemble in reverse order as above NOTE If after market air filter is used ensure it is installed according to the manufacturers recommended instructions PURIFIRE FILTER FILTER BRACKET MOUNTING SCRWES
10. her than fireplace surrounds mantels and trims and the limited 1 year warranty period for fireplace surrounds mantels and trims also applies to any implied warranties that may exist under applicable law Some jurisdictions do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to the purchaser What this limited warranty does not cover This limited warranty does not apply to products that have been repaired except by Dimplex or its authorized service representatives or otherwise altered This limited warranty does further not apply to defects resulting from misuse abuse accident neglect incorrect installation improper maintenance or handling or operation with an incorrect power source What you must do to get service under this limited warranty Defects must be brought to the attention of Dimplex Technical Service by contacting Dimplex at 1 888 DIMPLEX 1 888 346 7539 or 1367 Industrial Road Cambridge Ontario Canada N1R 7G8 Please have proof of purchase catalogue model and serial numbers available when calling Limited warranty service requires a proof of purchase of the product What Dimplex will do in the event of a defect In the event a product or part covered by this limited warranty is proven to be defective in material or workmanship during i the 2 year limited warranty period for products other than fireplace surrounds mantels and trims and ii the 1 year limited warr
11. ims and any repaired or replacement product or part to and from the authorized dealer s or service agent s place of business On site or in home services for surrounds mantels and trims may be performed at the purchaser s specific request and expense at Dimplex s then current rates for such services Dimplex will not be responsible for and this limited warranty shall not include any expense incurred for installation or removal of the surrounds mantels or trims or any part thereof or any replacement product or part including without limitation all shipping costs and transportation costs to and from the authorized dealer s or service agent s place of business and all labour costs Such costs shall be the purchaser s responsibility What Dimplex and its dealers and service agents are also not responsible for INNO EVENT WILL DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY WHETHER IN CONTRACT IN TORT OR ON ANY OTHER BASIS FOR ANY INDIRECT SPECIAL PUNITIVE EXEMPLARY CONSEQUENTIAL OR INCIDENTAL LOSS COST OR DAMAGE ARISING OUT OF OR IN CONNECTION WITH THE SALE MAINTENANCE USE OR INABILITY TO USE THE PRODUCT EVEN IF DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES COSTS OR DAMAGES OR IF SUCH LOSSES COSTS OR DAMAGES ARE FORESEEABLE IN NO EVENT WILL DIMPLEX OR ITS OFFICERS DIRECTORS OR AGENTS BE LIABLE FOR ANY DIRECT LOSSES CO
12. labels see below MODEL NUMBER FREQUENC Serial Number Model Number Serial Number Model Number Firebox Model Number T bi aN Serial Number Carton Bathroom Installation This firebox must be protected by a GFI receptacle or circuit If receptacle is used it must be readily accessible To prevent electrical shock this unit is an electrical appliance that is not watertight and must be installed as to prevent water from entering the unit This unit must be installed away from showers tubs etc Never locate fireplace where it may fall into a bathtub or other water containers Keep towels and other combustible materials 3 feet away from the front of the unit OPERATION The controls for the Electric Fireplace are located at the bottom right hand corner of the unit gee OVERHEAT INDICATOR ANUAL CONTROLS FIGURE 1 MANUAL CONTROLS A Main Power Switch l FAN CONTROL Main on off switch activates the flame effect SWITCH B Heater Control Switch Heater ON OFF switch activates the heater C Fan Control Switch Fan ON OFF switch activates the fan purifier A Mine MAIN POWER SWITCH HEATER CONTROL O SWITCH FIGURE 2 WALL MOUNTED CONTROLS The fireplace can be installed with wall mounted controls These controls include wall switches and thermostats see installation guide for details A Wall Mounted Switches Thi
13. n the lighting area If you have any technical questions regarding the operation of your fireplace or require service for your fireplace contact Dimplex North America customer service at 1 888 DIMPLEX 1 888 346 7539 CONTENTS PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 9 PAGE 10 Important Instructions Model and Serial Number Information Bathroom Installation Operation Maintenance Accessories Warranty IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS PLEASE RETAIN THIS USER S GUIDE FOR FUTURE REFERENCE When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following Read all instructions before using this fireplace This fireplace is hot when in use To avoid burns do not let bare skin touch hot surfaces The trim around the heater outlet becomes hot during heater operation Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9m from the front of the unit Extreme caution is necessary when any heater is used by or near children or invalids and whenever the fireplace is left operating and unattended Do not operate any fireplace if the heater has malfunctioned or if the fireplace has been dropped or damaged in any manner Do not use outdoors Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this
14. s model may be installed such that a wall mounted switch activates the flame effect and a wall mounted heater switch activates the heater fan control switch on unit must be set at ON position A wall mounted switch can also be installed to operate the heater independent of the flame Fan control cannot be wired to a wall mounted switch B Wall Mounted Thermostat This unit may be installed such that a wall mounted thermostat can adjust the heat temperature to your individual requirements Turn the thermostat control clockwise all the way to turn on the heater When the room reaches the desired temperature turn the thermostat knob counter clockwise until you hear a click Leave in this position to maintain 4 the room temperature at this setting For additional heat turn the thermostat clockwise until you hear the click again and the heater will turn on To turn the heater off turn the thermostat counter clockwise all the way and or turn the manual heater switch on the unit to the OFF position Fan control switch must be on to activate heater THE TEMPERATURE CUTOUT SWITCH The heater on this fireplace is protected with a safety device to prevent overheating Should the heater overheat a red light Fig 1 will be activated and an automatic cut out will turn the heater off The heater will re activate once the heater has cooled The overheat cutout will be triggered if the filter is dirty Follow filter maintenance on page 8 CAUTION If th