Home
Dell 2450 Server User Manual
Contents
1. Record the system configuration settings Update the embedded server management ESM firmware Update the basic input output system BIOS if necessary Use the resource configuration utility RCU diskette to save the RCU configura tion settings see your Users Guide for complete information During the upgrade procedure you must use a wrist grounding strap for ESD protection Dell PowerEdge 2450 Systems Information Update 1 5 1 6 Recording the System Configuration View the system configuration screens in the System Setup program and make a record of the settings Updating the ESM Firmware If an ESM firmware diskette Is included with the upgrade kit update your ESM firm ware with the version contained on that diskette by performing the following steps The latest version of the ESM firmware is available at http support dell com 1 Insert the ESM firmware diskette into the diskette drive 2 Reboot the system 3 Follow the instructions on the screen after the system completes the boot routine The message Successfully Completed Done appears on the screen 4 Remove the ESM firmware diskette from the diskette drive and follow the instructions on the screen to reboot the system Updating the BIOS If a BIOS diskette is included with the kit update your BIOS with the version con tained on that diskette by performing the following steps The latest version of the BIOS is available at http support dell com
2. 1 Insert the BIOS diskette into the diskette drive 2 Reboot the system 3 Follow the instructions on the screen after the system completes the boot routine 4 After the message BIOS has been successfully installed appears on the screen remove the BIOS diskette from the diskette drive and follow the instructions on the screen to reboot the system Saving RCU Configuration Settings Use the RCU diskette provided with the kit to save the current system configuration settings by performing the following steps 1 Insert the RCU diskette into the diskette drive and reboot the system 2 Press lt Enter gt when the Welcome screen appears The Main menu is displayed 3 Select Step 5 Save and Exit and then follow the online instructions to save the current system configuration information Dell PowerEdge 2450 Systems Information Update support dell com NOTE The RCU recognizes microprocessors operating at 450 MHz and faster The latest version of the RCU is available at http support dell com Removing the SEC Cartridge and Heat Sink NOTICE Follow the instructions in Precautionary Measures to ensure that the system is properly shut down and disconnected from all power sources Ensure that the system configuration screens are recorded as described in Before You Begin 1 Turn off the system including any attached peripherals and disconnect the power cable from the electrical outlet 2 _Open the system cove
3. heat sink 7 fi A a Pull the tab on one side of the guide bracket assembly away from the end of the heat sink and pull up slightly on the SEC cartridge and heat sink see Figure 1 4 b Pull the tab on the other end of the guide bracket assembly to disengage the tab on the heat sink Then lift the SEC cartridge and heat sink away from the guide bracket assembly see Figure 1 4 1 8 Dell PowerEdge 2450 Systems Information Update heat sink SEC cartridge a g 1 sel gt SS je guide bracket SX assembly gt J Figure 1 4 Removing the SEC Cartridge and Heat Sink From the PowerEdge 2450 N Installing the New SEC Cartridge and Heat Sink NOTICE All empty microprocessor connectors must be populated with a terminator card If your system supports more than one microprocessor and you are not installing the maximum number of microprocessors the remaining microprocessor connectors must have a terminator card NOTICE The terminator card must be rated to run at 133 MHz 1 Slide the SEC cartridge and heat sink into the guide bracket assembly and firmly seat them in the assembly until the tabs snap into place over the ends of the heat sink see Figure 1 5 support dell com Dell PowerEdge 2450 Systems Information Update 1 9 heat sink sem SEC cartridge gudebradet assembly N o wl Figure 1 5 Installing the New SEC Cartridge and Heat Sink Into the PowerEdge 2450 N 2 Replac
4. Dell PowerEdge 2450 Systems INFORMATION UPDATE www dell com DALO COM support dell com Notes Notices Cautions and Warnings Throughout this guide blocks of text may be accompanied by an icon and printed in bold type or in Italic type These blocks are notes notices cautions and warnings and they are used as follows NOTE A NOTE indicates important information that helps you make better use of your computer system NOTICE A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem CAUTION A CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury WARNING A WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious bodily injury Information in this document is subject to change without notice 2000 Dell Computer Corporation All rights reserved Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden Trademarks used in this text Dell the DELL E COM logo and PowerEdge are trademarks of Dell Computer Corporation ntel and Pentium are registered trademarks of Intel Corporation Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell Computer Corporation disclaims any propri etary interest in
5. d is off before removing the card cage Dell PowerEdge 2450 Systems Information Update 1 1 securing lever Sa A expansion card cage Figure 1 1 Removing the Expansion Card Cage 4 Locate the expansion card cage securing lever see Figure 1 1 Rotate the lever upward until it stops in an upright position 5 Lift the expansion card cage up and away from the chassis 6 Open the expansion card latch see Figure 1 2 and remove the filler bracket from the expansion slot expansion card latch expansion card card guide card edge connector expansion card connector nno expansion card cage Figure 1 2 Installing an Expansion Card 1 2 Dell PowerEdge 2450 Systems Information Update support dell com 10 11 12 13 Install the new expansion card Position the expansion card cage so that the riser board lies horizontally on your work surface Insert the card edge connector firmly into the expansion card connector on the riser board until the card is fully seated When the card is seated in the connector and the card mounting bracket is aligned with the brackets on either side of it close the expansion card latch If the expansion card is a full length card secure the inner end of the card by closing the latch on the card guide over the top edge of the card With the securing lever in the upright position lower the expansion card cage into place until it is aligned Rotate th
6. e securing lever downward until it is flush with the top of the chassis Make sure the riser board is fully seated in the RISER connector on the system board Reconnect any cables you removed in step 3 See the documentation that came with the card for information about its cable connections Close the system doors and then reconnect the system and peripherals to their AC power sources and turn them on To remove an expansion card perform the following steps if To release the expansion card from the card cage rotate the expansion card latch away trom the expansion card bracket If the expansion card is a full length card release the card s inner end by opening the tab on the card guide see Figure 1 2 Grasp the expansion card by its top corners and carefully remove it from the expansion card connector If you are removing the card permanently install a metal filler bracket over the empty card slot opening NOTE Installing a filler bracket over an empty expansion slot is necessary to maintain Federal Communications Commission FCC certification of the system The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system Replace the expansion card cage In the chassis as Instructed in steps 10 through 12 of the previous procedure Close the system doors and then reconnect the system and peripherals to their AC power sources and turn them on Dell PowerEdge 2450 Syste
7. e the air blower if it was removed in step 3 of the previous procedure see Figure 1 3 a Position your right thumb on the outside of the power supply enclosure beside the narrower front part of the air blower b Push firmly on the power supply enclosure to move it slightly toward the power supplies allowing extra clearance to install the air blower c Hold the air blower above the heat sink while tilting the back of the air blower slightly down and toward the back of the chassis d Slide the metal tab at the back right of the air blower carefully into the topmost slot at the top back of the chassis e With your left hand push down firmly on the front of the air blower until you hear it snap into place f Make sure that the top of the air blower is level if it is not level lift out the air blower and reinstall it making sure the tab goes into the slot at the very top of the back chassis g Plug in the Yshaped blower power cable to the connector on the interposer board 3 Replace the system cover 4 Reconnect your system and peripherals to their power sources 1 10 Dell PowerEdge 2450 Systems Information Update
8. ms Information Update 1 3 SCSI Hard Disk Drive Support Your system s integrated SCSI host adapter supports the Ultra3 also Known as Ultra160 SCSI standard as defined by the SCSI Trade Association The Ultra3 SCSI standard supports a combination of new SCSI performance and manageability enhancements to increase data throughput up to 160 megabytes per second MB sec For specific information about the Ultra3 SCSI standard see the SCSI Trade Association Web site at http www scsita org Your system employs an implementation of Ultra3 Ultra160 known as Ultra160 m The Ultra160 m and Ultra3 Ultra160 drives supplied by Dell are identical and are interchangeable The subsections describing SCSI and redundant array of independent disks RAID settings in Using the System Setup Program of your Dell PowerEdge 2450 Systems Users Guide have been combined to read as follows SCSI RAID Controller Selections are RAID Enabled SCSI Enabled and Off When you set the SCSI RAID Controller to RAID Enabled Channel A displays RAID and Channel B displays SCSI When you set it to SCSI Enabled Channel A and Channel B display SCSI When you set it to Off Channel A and Channel B display Off When installing the SCSI backplane daughter card as addressed in Installing Hard Disk Drives of the Dell PowerEdge 2450 Systems Installation and Troubleshooting Guide make sure to slide in the daughter card until it clicks and then lock the card into
9. place by closing the retention lever on the card s front edge Installing an Upgrade Microprocessor in PowerEdge 2450 Systems This section provides instructions for e Removing the single edge contact SEC cartridge and heat sink Installing the new SEC cartridge and heat sink Precautionary Measures Before you perform any of the procedures in this section take a few moments to read the following warning for your personal safety and to prevent damage to the system from electrostatic discharge ESD WARNING Follow these steps carefully to ensure your personal safety and a to protect the equipment Before you start to work on the system perform the following steps in the sequence listed 1 Turn off your system and any devices 1 4 Dell PowerEdge 2450 Systems Information Update support dell com Ground yourself by touching an unpainted metal surface on the chassis such as the metal around the card slot openings at the back of the system before touch ing anything inside your system While you work periodically touch an unpainted metal surface on the system chassis to dissipate any static electricity that might harm internal components Disconnect your system and devices from their power sources Also disconnect any telephone or telecommunication lines from the system Doing so reduces the potential for personal injury or shock In addition take note of these safety guidelines when appropriate When you disconnec
10. r See your system s nstallation and Troubleshooting Guide for specific instruc tions If needed 3 Remove the air blower if present see Figure 1 3 a Unplug the Yshaped air blower power cable from the interposer board b Position your right thumb on the outside of the power supply enclosure beside the narrower front part of the air blower c Push firmly on the power supply enclosure to move it slightly away from the air blower and allow extra clearance to remove the air blower d With your left hand pull the front of the air blower upward and away from the power supplies to unseat it You should hear it unsnap By pulling the air blower slightly away from the power supplies you avoid the need to use excessive force to clear the power supply enclosure e Slide the air blower slightly up and toward the front of the chassis until the metal tab at the back right of the air blower slides out of the small slot at the top back of the chassis Dell PowerEdge 2450 Systems Information Update 1 7 air blower power supply ns enclosure air blower power cable Figure 1 3 Removing the Air Blower 4 Remove the SEC cartridge and heat sink as follows CAUTION The SEC cartridge and heat sink can become extremely hot dur ing system operation Be sure that they have had sufficient time to cool before you touch them CAUTION When handling the SEC cartridge and heat sink take care to avoid sharp edges on the
11. t a cable pull on its connector or on its strain relief loop not on the cable itself Some cables have a connector with locking tabs if you are disconnecting this type of cable press in on the locking tabs before disconnecting the cable As you pull connectors apart keep them evenly aligned to avoid bending any connector pins Also before you connect a cable make sure both connectors are correctly oriented and aligned Handle components and cards with care Don t touch the components or contacts on a card Hold a card by its edges or by Its metal mounting bracket Hold a component such as a microprocessor chip by its edges not by its pins NOTICE If your system has two microprocessors installed the secondary microprocessor must be the same type and have the same operating fre quency and cache size as the primary microprocessor For example if the system you are installing has a 500 megahertz MHz Intel Pentium III primary microprocessor the secondary microprocessor must also be a 500 MHz Pentium III microprocessor NOTICE All empty microprocessor connectors must be populated with a terminator card If your system supports more than one microprocessor and you are not installing the maximum number of microprocessors the remaining microprocessor connectors must have a terminator card NOTICE The terminator card must be rated to run at 133 MHz Before You Begin Before shutting down your system perform these preliminary steps
12. trademarks and trade names other than its own August 2000 P N O6NWC Rev A01 support dell com Dell PowerEdge 2450 Systems Information Update This document updates information on the following topics for your Dell PowerEdge 2450 system e installing and removing expansion cards _ Small computer system interface SCSI hard disk drive support e Installing an upgrade microprocessor in PowerEdge 2450 systems Installing and Removing an Expansion Card To install an expansion card perform the following steps WARNING Before you perform this procedure you must turn off the system and disconnect it from its AC power source For more information see the safety information in your system documentation 1 Turn off the system including any attached peripherals and disconnect the sys tem from the electrical outlet 2 Prepare the expansion card for installation and open the system doors NOTICE See Protecting Against Electrostatic Discharge in the safety instructions in your system documentation See the documentation that came with the expansion card for information on configuring the card making internal connections or otherwise customizing the card for your system 3 _ Check any cables connected to expansion cards through the back panel open ings Disconnect any cables that will not reach to where the cage must be placed upon removal from the chassis NOTICE Verify that the power LED on the riser boar