Home
Compaq uSign 100 Network Router User Manual
Contents
1. Overall size 129mm wide 5 1 in 146mm length 5 75 in 40mm thick including back plate 1 57 in Display 3 3 inch diagonal signature area 6 4 LCD screen amp Resistive touch pad Touchpad Resistive transparent pressure sensitive screen Display STN monochrome LCD Sampling Rate Up to 190 samples per second Touchpad Resolution up to 929 dpi Display Resolution LCD Resolution 192 x 64 dots Overlay Screen Removable Field replaceable signature surface 6 5 Communication interface RS232 Baud rates 1200 to 115200 Default 9600 baud data bits 8 Parity none Stop bit 1 USB 2 0 Full Speed Common Device Class 6 6 LED Two individual LEDs one green amp one red Signature Pad or Host controlled 6 7 Agency Approvals FCC Class B amp CE The uSign 100 is UL Listed The product is RoHS compliant 6 8 Electronics MTBF Electronics MTBF 200 000 POH based on Bellcore standard 6 9 Electro Static Discharges ESD The electronics must survive ESD of 4kV contact and 8kV air discharge Meets or exceeds IEC 1000 4 2 6 10 Environmental Temperature ranges Operating 1to45C 34 to 113 F Storage sealed container 10 to 70 C 14 to 158 F Relative humidity Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 11 of 18 uSign User Manual 10 to 95 non condensing Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 12 of 18 uSign Us
2. 3 0 Model Designations uSign 100 IDUA 01x100 uSign 200 IDUA 01x500 The x defines the communication interface 2 RS232 and 6 USB CDC 4 0 Terms amp Abbreviations COM Host communication port Host Personal Computer Terminal or similar device LCD Liquid Crystal Display LED Light Emitting Diode mA Milli Amperes of electrical current RS232 Serial communications USB Universal Serial Bus serial communications VDC Volts Direct Current 5 0 Installing uSign uSign is designed for an indoor environment Locate the uSign where it is convenient to operate and protected from heat or direct sunlight Position the uSign so the signature pad area is easy to reach and the immediate area is clear for authoring the signature The uSign housing has threaded inserts in the bottom and relief areas for hook amp loop fasteners A metal mounting bracket with keyhole amp screw mounting is mounted to the back of the housing The uSign 100 with an RS232 interface uses a standard DB25 connector and is supplied power with a 9VDC power adaptor The uSign 200 with an RS232 interface uses a standard DB9 connector and uses a 5VDC power adaptor The input voltage on the power adaptors may be limited do not exceed the input voltage rating of the power adaptor Connect the power adaptor after the other connections are made The uSign having a USB communication interface receives power from the host through the USB port For both interface types and w
3. 7 3 2 Start Capturing use FBP format 1 Command string C1 Response string C1 7 3 3 Start Capturing use FBP format 2 Command string C2 Response string C2 7 3 4 Turn red led on Command string C3 Response string C3 7 3 5 Turn red led off Command string C4 Response string C4 7 3 6 Clear CMP format mode data Command string C5 Response string C5 7 3 7 Get data 0x00 Command string C6 or D4 or D5 Response string 00 7 3 8 Start Capturing use CMP format Command string C7 Response string C7 7 3 9 Reset points counter Command string DO Response string DO 7 3 10 Get point counter high byte Command string D1 Response string D1 7 3 11 Get point counter low byte Command string D2 Response string D2 Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 14 of 18 uSign User Manual 7 3 12 Start Capturing use FBP format 0 Command string D6 Response string D6 7 4 Multi byte commands 7 4 1 Initialize device Command string 28 10 00 00 Response string DC 05 7 4 2 Get PW120 Version Command string 2A 10 00 00 Response string 01 00 7 4 3 Test device Command string 52 12 00 00 Response string 52 12 7 4 4 Set CTS control Command string 22 15 01 00 01 enable 00 disable Response string 01 7 4 5 Set interval between two points Command string 28 15 01 00 xx Response string 01 7 4 6 Get data 0x00 0x01 Command strin
4. Manual uSign 100 SIGNATURE CAPTURE PAD Figure 4 Outline Drawing for uSign 100 Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 17 of 18 uSign User Manual uSign 200 SIGNATURE CAPTURE PAD 34 00 146 00mm 123 00mm Figure 5 Outline Drawing for uSign 200 Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 18 of 18
5. IDT CH Value thr Value through firnavation Innovation USER MANUAL uSign Signature Capture Module Models uSign 100 amp uSign 200 C FE 80084501 001 A 04 24 2007 uSign User Manual FCC WARNING STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications FCC COMPLIANCE STATEMENT This device complies with Part 15 of the FCC Rules Operation of this device is subject to the following conditions this device may not cause harmful interference and this device must accept any interference received including interference that may cause undesired operation CANADIAN DOC STATEMENT This digital apparatus does not exceed the Class B limits for radio noise for digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de las classe B prescrites dans le R glement sur le brouillage radio lectrique e dict par les minist re de
6. SB communication uses the Windows USB CDC driver included in Windows 2000 amp XP operating systems ID TECH provides an INF file for use with the CDC driver Note Windows XP with Service Pack 1 can cause intermittent problems use Service Pack 2 Connect the USB connector to the PC and insure it is fully seated into the jack If the LEDs do not light check the connections and the availability of power from the Host When the USB connection is recognized by the operating system for the first time a Found New Hardware message is given The operating system must install the uSign INF setup file uSignUsbCDC inf for the system to communicate with the uSign Retrieve the uSignUsbCDC inf and companion usbser sys files from the ID TECH website and save the files in a convenient location on the PC system The New Hardware Wizard window appears Follow the directions and the wizard properly installs the INF setup information into the operating system Select the No not this time button and Click Next gt to continue Then select the Install from a list or specific location advanced button and Click Next gt to continue Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 8 of 18 uSign User Manual Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for USB Device V D If your hardware came with an installation CD lt 3 or flo
7. USIgN 200 cece sees cee eee eens 18 Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 5 of 18 uSign User Manual 1 0 Introduction The use of electronically captured signatures has become common for Point of Service POS applications Electronic signature capture reduces transaction time eliminates sorting amp sending paper provides convenient electronic storage amp transmission and gives legal accountability non repudiation for POS transactions uSign is an electronic signature capture device with a back lighted graphic LCD display and touch sensitive screen that is the signature panel Authors can view their signatures in real time during the signing process Signatures are compressed and provided to a Host system for signature amp data storage The LCD display allows for interactive text which supports pen tap commands and function selections The interactive Host operations allow selections and navigations through transactions with just the stylus The LCD amp touch sensitive screen are surrounded in a plastic housing The housing provides a tethered non electronic stylus The stylus is fastened to the housing in a way to allow stylus replacement A mounting plate secures the uSign housing to a counter top or other mounting surface An overlay covers and protects the signature area of the uSign display The overlay is removable allowing replacement if the signature area beco
8. er Manual 7 0 uSign commands description Version 0 02 Date 2007 03 19 Note digits are given in little endian format 7 1 Command protocol Host to device STX LenL LenH CommandData Lrc1 Lrc2 ETX STX 0x02 1 byte LenL LenH sizeof CommandData 2 bytes CommandData main command string Several bytes needed Lrc1 Exclusive or of CommandData 1 byte Lrc2 Sum of CommandData 1 byte ETX 0x03 1 byte Device to Host STX LenL LenH ResponseData Lrc1 Lrc2 ETX STX 0x02 1 byte LenL LenH sizeof ResponseData 2 bytes ResponseData main response string Several bytes needed Lrc1 Exclusive or of ResponseData 1 byte Lrc2 Sum of ResponseData 1 byte ETX 0x03 1 byte 7 2 System Commands 7 2 1 Get firmware version Command string 78 01 Response string IDTECH USIGN V0 02 7 2 2 Get serial number Command string 78 02 Response string Serial number 7 2 3 Get clip area Command string 7A 04 01 Response string Clip area data 8 bytes Clip area is a rectangle coded as left 2 bytes top 2 bytes right 2 bytes bottom 2 bytes 7 2 4 Set clip area Command string 7A 04 02 Clip area data 8 bytes Response string OxEO 7 2 5 Clear clip area Command string 7A 08 Response string OxEO Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 13 of 18 uSign User Manual 7 3 One byte commands 7 3 1 Stop Capturing Command string CO Response string CO
9. g 2A 15 00 00 Response string 00 01 7 4 7 Calibrate the device Command string 30 15 00 00 Response string 01 7 4 8 Set offset position Command string 31 15 04 00 xx xx xx xx offset point Response string 01 7 4 9 Get data 0x01 Command string 32 15 00 00 Response string 01 7 4 10 Offset using control Command string 34 15 01 00 01 enable 00 disable Response string 01 Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 15 of 18 uSign User Manual 7 4 11 Stop Capturing Command string 40 30 00 00 Response string 7 4 12 Start Capturing use FBP format 1 Command string 41 30 00 00 Response string 7 4 13 Clear display screen Command string 40 32 00 00 Response string 7 4 14 Draw line Command string 43 32 08 00 X1 2 bytes Y1 2 bytes X2 2 bytes Y2 2 bytes Response string Line is defined by two points x1 y1 x2 y2 7 4 15 Draw hollow rectangle Command string 50 32 08 00 Left 2 bytes Top 2 bytes Right 2 bytes Bottom 2 bytes Response string 7 4 16 Draw solid rectangle Command string 51 32 08 00 Left 2 bytes Top 2 bytes Right 2 bytes Bottom 2 bytes Response string 7 4 17 Draw text Command string 80 32 String Length 6 00 X position 2 bytes Y position 2 bytes String Length 2 bytes String Response string Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 16 of 18 uSign User
10. hen power is applied the green amp red LED on the uSign are on for a moment go off and then the green is on and flashing If the LED does not light check the connections and the availability of power from the power outlet With the green LED flashing the LCD screen displays IDTECH uSign Version x xx When the signature screen is touched or commands are received from a Host the LED is turned off and the screen is cleared for Host operations The Green LED is controlled and is on when uSign is in the capture mode the red LED is host controlled The communication type can be RS232 or USB CDC Use the Communication Interface section that corresponds with the interface of your uSign unit Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 7 of 18 uSign User Manual 5 1 Communication Interfaces RS232 The uSign has a communication cable with a DB25 100 Model or DB 9 200 Model connector that fits the computer serial RS232 COM port connection See the Specifications Interface Section for COM port settings Connect the RS232 connector to the PC and insure it is fully seated into the connector Connect the power adaptor output to the power input socket on the back of the DB connector shell Connect the power adaptor to the AC line power outlet USB The USB interface is a Communication Device Class that opens a virtual COM Port which operates as though the COM was an RS232 device The U
11. mande nn 14 7 3 1 StoP erte lee DEE 14 7 3 2 Start Capturing use FBP format 1 0 eee eceeeeeeeeeeeeeeeeeeeeeeeeeees 14 7 3 3 Start Capturing use FBP format 2 2cccccccscatecoiiianenana 14 7 3 4 KEIER ee 14 K E Ser Nie REG led Off EE 14 7 3 6 Clear CMP format mode data 14 Foot Getdata 0X00 a nih oo cated aadi ngid ai a 14 7 3 8 Start Capturing use CMP Tomat 14 7 3 9 e eieiei EE 14 7 3 10 Get point counter high DYl6 ii an avian avian Gti ann aries 14 7 3 11 Get point counter low byte sssssssseeneeessssenrrnnnnesseerrrrnnnnnnneeerenne 14 7 3 12 Start Capturing use FBP format D 15 7 4 Multi byte COMINGS EE 15 7 4 1 iw WE Eer 15 1 42 Gr PWI2O Ee 15 7 4 3 e e Ee 15 TAA EE 15 7 4 5 Set interval between two points 15 Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 4 of 18 uSign User Manual 7 4 6 Get data 0x00 0X01 ugeet 15 7 4 7 e eene 15 7 4 8 Set Offset position AEN 15 LAO EE 15 FAO OUSEUUSING CONG E 15 PAAT Stop CAO TUM E 16 7 4 12 Start Capturing use FBP format 1 0 eee ee ceeeeeeeeeeeeeeeeeeeeeeeaeees 16 7 4 13 Clear display screen 16 TAAA le 16 7 4 15 Draw hollow ee ne UE 16 7 4 16 Draw solid rectangle E 16 7 4 17 Draw TON ege eege eet 16 Table of Figures Figure 1 New Hardware Wizard opening window 9 Figure 2 Browse for AE 9 Figure 3 Installation Warning Message 10 Figure 4 Outline Drawing for USIgN 100 17 Figure 5 Outline Drawing for
12. me for ID TECH any other liabilities in connection with the sales of any product In no event shall ID TECH be liable for any special incidental or consequential damages to purchaser or any third party caused by any defective item of equipment whether that defect is warranted against or not Purchaser s sole and exclusive remedy for defective equipment which does not conform to the requirements of sales is to have such equipment replaced or repaired by ID TECH For limited warranty service during the warranty period please contact ID TECH to obtain a Return Material Authorization RMA number amp instructions for returning the product THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES OR GUARANTEES EXPRESS OR IMPLIED OTHER THAN THOSE HEREIN STATED THIS PRODUCT IS SOLD AS IS IN NO EVENT SHALL ID TECH BE LIABLE FOR CLAIMS BASED UPON BREACH OF EXPRESS OR IMPLIED WARRANTY OF NEGLIGENCE OF ANY OTHER DAMAGES WHETHER DIRECT IMMEDIATE FORESEEABLE CONSEQUENTIAL OR SPECIAL OR FOR ANY EXPENSE INCURRED BY REASON OF THE USE OR MISUSE SALE OR FABRICATIONS OF PRODUCTS WHICH DO NOT CONFORM TO THE TERMS AND CONDITIONS OF THE CONTRACT The information contained herein is provided to the user as a convenience While every effort has been made to ensure accuracy ID TECH is not responsible for damages that might occur because of errors or omissions including any loss of pr
13. mes worn from stylus use Customer specific front overlay designs are possible as needed by an application There are two major uSign housing configurations The first is a signature pad enclosed in a stylish housing This uSign is a POS System level product intended for signature capture at a transaction counter A convenient palm rest area below the signature panel provides support during the signing process The second configuration is an OEM version with a smaller housing and intended for mounting to a vertical or near vertical surface Both products have the same internal components and operations 2 0 Features Electronic signature capture w Buffered signature capability Sampling rate up to 190 dots per second Real time signature capture with 5 1 compression Raw data output available Algorithms to filter spikes provide Smoothing amp Calibration algorithms Command amp response driven operations through an API Graphic display of signature during capture Display graphics under Host control when not in signature process Touch pad dot position matches LCD pixel locations Operates with Windows 2000 XP and Vista operating systems Replaceable non active tethered stylus Resistive touch pad with transparent replaceable protective overlay The uSign 100 is UL listed both uSign 100 amp uSign 200 are RoHS compliant Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 6 of 18 uSign User Manual
14. ofit or other commercial damage nor for any infringements or patents or other rights of third parties that may result from its use The specifications described herein were current at the time of publication but are subject to change at any time without prior notice ID TECH 10721 Walker Street Cypress CA 90630 714 761 6368 www idtechproducts com Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 3 of 18 uSign User Manual Table of Contents ENNER tele Led E 6 20 Features aana es Sit ihe Sate BP eh at eh oe eC eat ci bie Ui ce Ul ech tal eat 6 3 0 Jl 7 ALO ele Ne E 7 4 1 Communication Interface ocziesesascesiesreniee arte aussie 8 4 2 USB CDC Setup ME 10 5 0 Terms amp Abbreviations AAA 7 G0 Specifications EE 10 SCH Ewert Eege 10 6 2 Physical housing uSign TEE dee 10 6 3 Physical housing uSign 200 11 6 4 LCD screen amp Resistive touch Dad an 11 6 5 Communication Imiertace EE 11 6 amp 6 VED a A E A AIR A A A EAA 11 6 7 EEN 11 6 8 gt Electronics A DEES 11 6 9 Electro Static Discharges ESD csccsticrccctainrssatticraettioinieiisccectietaettieid 11 6 10 ENVirOniMental xj ticki Aere 11 7 0 uSign commands CeSCTIPTION EE 13 GC E ee nu ee Bee EE 13 7 2 System EIERE EELER 13 7 2 1 Get firmware version 13 7 2 2 Get serial DEUFEUEEeeeieeeddee de gece edd Seet 13 K SE E E AE E 13 Tew SOL CID EE 13 7 2 5 Clear clip re 2 E 13 7 3 One byte com
15. ppy disk insert it now What do you want the wizard to do O Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue Figure 1 New Hardware Wizard opening window Browse and select the folder where the uSignUsbCDC inf and companion usbser sys files are located Click Next gt to continue Found New Hardware Wizard Please choose your search and installation options Fae g Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed C Search removable media floppy CD ROM Include this location in the search C Program Files uSign USB CDC files w Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware lt Back Next gt Cancel Figure 2 Browse for File Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 9 of 18 uSign User Manual There is a warning window that the INF file is not registered Click Continue Anyway Click Finish to complete the INF installation Hardware Installation The software you are installing for this hardware IDTECH USB RS232 uSign has not passed Window
16. s Communications du Canada CE STANDARDS An independent laboratory performed testing for compliance to CE requirements The unit under test was found compliant to Class B ID TECH is a registered trademark of International Technologies amp Systems Corporation uSign and Value through Innovation are trademarks of International Technologies amp Systems Corporation USB Universal Serial Bus Specification is Copyright by Compaq Computer Corporation Intel Corporation Microsoft Corporation and NEC Corporation Windows Excel amp Notepad are registered trademarks of Microsoft Corporation Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 2 of 18 uSign User Manual LIMITED WARRANTY ID TECH warrants to the original purchaser for a period of 12 months from the date of invoice that this product is in good working order and free from defects in material and workmanship under normal use and service ID TECH s obligation under this warranty is limited to at its option replacing repairing or giving credit for any product which has within the warranty period been returned to the factory of origin transportation charges and insurance prepaid and which is after examination disclosed to ID TECH s satisfaction to be thus defective The expense of removal and reinstallation of any item or items of equipment is not included in this warranty No person firm or corporation is authorized to assu
17. s Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation Figure 3 Installation Warning Message 5 2 USB CDC Setup The following steps provide a check on the USB CDC COM port selected by the operating system This step is used only if there is a need to confirm operation and possible to review the communication port number Open the Windows Control Panel and follow the selections System Hardware Tab and Device Manager Expand the Port COM amp LPT folder There should be an item IDTECH USB RS232 uSign COM where is a Port number uSign is set up and communicating 6 0 Specifications 6 1 Power requirement Voltage uSign 100 is 9VDC and uSign 200 is 5VDC Current 150mA typical RS232 Power AC adapter center positive adaptor plug output USB Power Host USB port 6 2 Physical housing uSign 100 Overall size 113mm wide 77 5mm high 31 5mm thick including back plate Display 3 3 inch diagonal signature area Copyright 2006 International Technologies amp Systems Corp All rights reserved Page 10 of 18 uSign User Manual 6 3 Physical housing uSign 200
Download Pdf Manuals
Related Search
Related Contents
Klipsch IN-WALL R-1650-W User's Manual Zenith VCM321 VCR Prevenção e controlo de Legionella nos sistemas de água Benutzerhandbuch WARNING/ATTENTION USER GUIDE GUIDE D`UTILISATION orfèvrerie - céramiques - armes et souvenirs Manuel de Programmation - CCTV Gembird Universal Multimedia/HiFi kit Trust 70W Notebook Power Adapter 使用上の注意は、 カタログ又は取扱説明書をお読みください Copyright © All rights reserved.