Home
Breville BJE820XL Juicer User Manual
Contents
1. To Generator Ground Bus Briggs amp Stratton Power Products Automatic Transfer Switch Installation and Owner s Manual Briggs Stratton POWER PRODUCTS SYSTEM OPERATION To select automatic transfer operation do the following I Set service disconnect switch that sends utility power to transfer switch to On position 2 Set generator s main circuit breaker to its On position Install 15 Amp fuse in control panel on generator 4 Set AUTO OFF MANUAL switch on generator to AUTO position The system will now be in automatic operation mode TESTING THE AUTOMATIC TRANSFER SWITCH Turn the service disconnect feeding the transfer switch to the Off position The automatic sequence will follow To go back to utility power turn the service disconnect to the On position Automatic Sequence Utility Fail Utility voltage sensor senses when utility voltage is below 70 percent of nominal Engine start sequence is initiated after 6 second time delay Engine Warm Up Time delay to allow for engine warm up before transfer fixed at 20 seconds or 50 seconds with optional cold weather package Transfer Transfers from utility to standby supply occurs after standby voltage is above set levels Minimum engine run time is 4 minutes after transfer Utility Pickup Voltage pickup level
2. G n ratrice INSTALLATION Commutateur de transfert automatique Briggs amp Stratton Power Products Guide d installation et d utilisation Briggs amp Stratton POWER PRODUCTS MODELE 01813 N Branchement de l Electricit de Service Contacts Normalement Ferm s Branchement de Raccordement n i i des Charges la G n ratrice LT g Terminaux AT Neutre Languette de Mise la Masse Panneau de Distribution Principal Principal Barre Neutre Vers la G n ratrice Barre de Mise L la Terre 4 Vers l Alimentation de Service MOD LE 01814 Branchement de l lectricit de y T Contacts Service Normalement lt Ferm s H Raccordement Branchement de L ud la G n ratrice les Charges d Terminaux LT Neutre Languette de Mise la Masse Panneau de Distribution Principal Princip
3. Installation and Owner s Manual Briggs amp Stratton POWER PRODUCTS SCHEMATICS TRANSFER SWITCH WIRING DIAGRAM WIR AGRAM CONTROL BMARD T O UTILITY 5 O di 7 556 m 7 NI B EE 24 m L CNN 127 33 O Net Z O nci 00 00 O ncz OOo 00 Nca TRANSFER O iu PR Q o SWITCH 00 00 NE 00 00 M EY UN joo oo U amp Aes FUSE da E Ti HOLDER El Eb id al iN El Briggs amp Stratton Power Products Automatic Transfer Switch So amp LT UTILITY 240 VAC Briggs amp Stratton Power Products Automatic Transfer Switch Briggs amp Stratton Installation and Owner s Manual POWER PRODUCTS TRANSFER SWITCH EXPLODED VIEW amp PARTS LIST MODEL 01813 23 24 elsa 29 23 Item Part Description Item Part Description 192154GS ENCLOSURE 17 192151GS HOLDER Fuse 2 192155GS BACK PANEL 18 192557GS STANDOFF Purse Lock 3 191995GS TRANSFER SWITCH 100A with 19 190850GS DECAL ATS BSPP Cover amp Handle 20 192702GS DECAL Term Strip 4 36701GS SCREW 21 B5106GS DECAL Connection Utility 5 36903GS SCREW 22 B5107GS DECAL Connection Generator 6 36905GS SCREW 23 192688GS DECAL 100A ATS 7 36933GS SCREW 24 192690GS DECAL UL Listed
4. cc cc c c ce ec cc 16 MISE L ESSAI DU COMMUTATEUR DE TRANSFERT R GLES DE S CURIT 1 stecken Doria 17 AUTOMATIQUE paisa 22 INTRODUCTION j osa 18 S quence Automatique 22 Au Propri taire R sidentiel ou Commercial 18 Panne de l alimentation de service 22 Au D taillant l Entrepreneur Proc dant R chauffement du moteur 22 l Inscallation erre rent RI a 18 Transfert ari e 22 Conseils au Propri taire 18 Prise en charge de l alimentation de service 22 Responsabilit s de l installateur 18 Retranstert 026 ss ra 22 Description de l quipement 19 Refroidissement du moteur 22 INSTALLATION coord aan 19 Caract ristiques oir eii 22 Deballage rocosas Bias BSN aE 19 Mod le 01813 e eeeee 22 V rification de la Livraison 19 Mod le O1814 22 Contenu de la Bo te 19 Si vous Devez Communiquer avec l Usine 22 Dimensions d installation 19 D PANNAGE c REA RR porron 23 Consignes d installation 20 REMARQUES sss 6 425006 003000 PETERET RR Meat a 24 Interconnexions du C blage d Alimentation 20 21 SCH MAS VUES CLAT ES LISTES DES PI CES 10 13
5. v ele 4 j Dimensions du Boitier Dimensions d Installation Mod le 01813 lt AX v o Dimensions du Boitier Dimensions d Installation Modele 01814 Tel qu illustr le bo tier du commutateur de transfert est q g n ralement fix l aide des trous pr for s Commutateur de transfert automatique Bri Guide d installation et d utilisation Briggs Stratton POWER PRODUCTS Consignes d installation Le commutateur de transfert automatique est contenu dans un bo tier de type NEMA 3R adapt pour usage interne et externe Consignes d installation du commutateur de transfert automatique Installation du commutateur sur une structure portante ferme et robuste Le commutateur doit tre install avec les connexions de conduit de fo de mat riel de NEMA 3R minimum Au besoin nivelez le commutateur pour viter les distorsions Ceci peut tre accompli en ins rant des rondelles entre le bo tier du commutateur et la surface de fixation e NE JAMAIS installer le commutateur dans un endroit une substance corrosive pourrait s y
6. POWER PRODUCTS SOLUTION I R armez le disjoncteur de la g n ratrice 2 Reportez vous au manuel de la g n ratrice l R armez le disjoncteur de l alimentation de service 2 Attendez que la tension de service revienne la normale Le moteur devrait s teindre apr s minute V rifiez les contacts normalement ferm s et ou v rifiez le c blage de commande des charges externes Commutateur de transfert automatique Briggs amp Stratton Power Products Briggs amp Stratton Guide d installation et d utilisation POWER PRODUCTS REMARQUES 24 GARANTIE DU PROPRI TAIRE D UN PRODUIT BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC Prise d effet au er Janvier 2003 annule et remplace toutes les garanties pr c dentes et les garanties ant rieures au er Janvier 2003 GARANTIE LIMIT E Briggs amp Stratton Power Products Group LLC r parera ou remplacera sans frais toutes pi ces d quipement d fectueuses comportant un vice de mat riau ou un d faut de fabrication ou les deux En vertu de la pr sente garantie les frais de transport des pi ces soumises pour r paration ou remplacement sont la charge de l acheteur La pr sente garantie sera en vigueur durant les p riodes stipul es ci dessous et est assujettie aux conditions stipul es ci dessous Pour obtenir des services en vertu de la garantie veuillez consulter notre Outil de recherche d un Service apr s vente agr au http www briggsp
7. R chauffement du moteur Avant le transfert il y a un d lai de r chauffement du moteur de 20 secondes ou de 50 secondes si l ensemble pour temps froid offert en option est install Transfert Le transfert de l alimentation de service la g n ratrice de secours se produit apr s que la tension de la g n ratrice d passe un seuil pr d termin Apr s le transfert le moteur tourne durant au moins 4 minutes Prise en charge de l alimentation de service La tension de prise en charge est de 80 pourcent de la tension nominale 22 s amp Stratton Power Products S Retransfert Le transfert de l alimentation de la g n ratrice de secours l alimentation de service se fait 10 secondes apr s que la tension de service ait d pass le niveau de prise en charge Refroidissement du moteur Le moteur tourne pendant 60 secondes apr s le transfert Caract ristiques UL 1008 Enum r Commutateur de Transfert Mod le 01813 Charge maximum circuit du point d alimentation des charges 100 Amp res Tension nominale C A 250 Volts POIES io tcs 2 Fr quente emir creer ep REY aoa 50 60 Hz Intensit de d faillance nominale 22 000 Amperes Sym triques RMS Poids a eee ee Cet 9 5 kg 21 Ib Modele 01814 Charge maximum circuit du point d alimentation des charges 200 Amp res Tension nominale C A 250 Volts Pol coco iaa RR Re nn 2 Fr quence ita e dete 50 6
8. Usage a des fins commerciales aucune 90 jours 90 jours 1 an 1 an Le moteur et les batteries de d marrage sont garantis uniquement par les fabricants de ces produits 2 ans pour tous les produits grand public de l Union europ enne Les pi ces seulement la deuxi me ann e pour l usage par un consommateur de la G n ratrice portative et du Groupe lectrog ne moins de 10 kW a l ext rieur de l Union europ enne La p riode de garantie d bute a la date d achat par le premier acheteur au d tail ou par le premier utilisateur commercial final et se prolonge pour la dur e stipul e dans le tableau ci dessus Usage par un consommateur signifie utilisation domestique personnelle dans une r sidence par l acheteur au d tail Usage a des fins commerciales signifie toute autre utilisation y compris a des fins commerciales g n rant de revenus ou de location Aux fins de la pr sente garantie d s qu un quipement a t utilis commercialement une fois il est par la suite consid r comme tant d usage a des fins commerciales L quipement utilis pour l alimentation principale n est pas couvert par la pr sente garantie Les nettoyeurs a haute pression lectriques utilis s a des fins commerciales ne sont pas couverts par la pr sente garantie POUR EXERCER LA GARANTIE SUR TOUT PRODUIT FABRIQUE PAR BRIGGS amp STRATTON IL N EST PAS NECESSAIRE DE L ENREGISTRER CONSERVEZ LE REGU COMME PREUVE D ACHAT SI LORS D UNE RECLAMATION DE
9. 100A ATS 8 193159GS DECAL Reinstall After 25 190992GS DECAL Warning Shock 9 191668GS CONTROL Board 26 190984GS DECAL Fuse 10 192701GS SPACER Nylon 27 B4986GS DECAL Ground B4856GS LUG Ground 28 192597GS DECAL Utility 240V AC 12 22097GS WASHER Lock 29 192165GS DECAL APPVD CB 13 22473GS WASHER 30 193307GS DECAL Load 14 22127GS NUT 3 23897GS WASHER 15 190841GS TERMINAL Neutral 32 23762GS WASHER 16 B4857GS FUSE 33 36901GS SCREW Briggs amp Stratton Power Products Automatic Transfer Switch Installation and Owner s Manual Briggs Stratton POWER PRODUCTS TRANSFER SWITCH EXPLODED VIEW amp PARTS LIST MODEL 01814 Item Part 192156GS 192170GS 192024GS 36701GS 36903GS 36905GS 36901GS 193159GS 191668GS 192701GS B4856GS 22097GS 22473GS 22127GS 192696GS B4857GS 23 Description ENCLOSURE BACK PANEL TRANSFER SWITCH 200A with Cover amp Handle SCREW SCREW SCREW SCREW DECAL Reinstall After CONTROL Board SPACER Nylon LUG Ground WASHER Lock WASHER NUT TERMINAL Neutral FUSE Item Part 17 192151GS 18 192557GS 19 190850GS 20 192702GS 21 B5106GS 22 B5107GS 23 192689GS 24 192691GS 25 190992GS 26 190984GS 27 B4986GS 28 192597GS 29 192166GS 30 193307GS 31 23897GS 32 23762GS Description HOLDER Fuse STANDOFF Purse Lock DECAL ATS BSPP DECAL Term Strip DECAL Connection Utility DECAL Connection Generator
10. DECAL 200A ATS DECAL UL Listed 200A ATS DECAL Warning Shock DECAL Fuse DECAL Ground DECAL Utility 240V AC DECAL APPVD CB DECAL Load WASHER WASHER Briggs amp Stratton Power Products Automatic Transfer Switch Briggs amp Stratton Installation and Owner s Manual POWER PRODUCTS NOTES BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC EQUIPMENT OWNER WARRANTY POLICY Effective January 1 2003 replaces all undated Warranties and all Warranties dated before January 1 2003 LIMITED WARRANTY Briggs amp Stratton Power Products Group LLC will repair or replace free of charge any part s of the equipment that is defective in material or workmanship or both Transportation charges on parts submitted for repair or replacement under this warranty must be borne by purchaser This warranty is effective for the time periods and subject to the conditions stated below For warranty service find the nearest Authorized Service Dealer in our dealer locator map at www briggspowerproducts com THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM PURCHASE OR TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW Some states or countries do not allow limitations on how long an implied warranty lasts
11. I Rearme el disyuntor del generador 2 Consulte el manual del generador I Rearme el disyuntor de desconexi n de servicio 2 Espere a que se restablezca la normalidad en la tensi n de la red p blica El motor deber a detenerse despu s de minutos Compruebe si el contacto NC funciona correctamente y verifique el cableado de control de la carga externa Conectador autom tico de Briggs amp Stratton Power Products Manual de Instalaci n y del Propietario Briggs amp StraHon POWER PRODUCTS NOTAS 35 POL TICA DE GARANT A PARA EL PROPIETARIO DE EQUIPOS BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC Vigente a partir de Enero 1 2003 reemplaza todas las Garant as previas sin fecha y todas las Garant as fechadas antes de Enero 1 2003 GARANT A LIMITADA Briggs 8 Stratton Power Products Group LLC reparar o sustituir sin cargo alguno cualquier componente del equipo que presente defectos de materiales y o mano de obra Los gastos de transporte de las piezas enviadas para reparar o sustituir conforme a los t rminos de esta garant a correr n a cargo del comprador El periodo de vigencia y las condiciones de esta garant a son los que se estipulan a continuaci n Para obtener servicio en garant a localice el distribuidor de servicio autorizado m s pr ximo en nuestro mapa de distribuidores en www briggspowerproducts com NO EXISTE NINGUNA OTRA GARANT A EXPL CITA LAS GARANT AS IMPL CITAS INCLUIDAS LAS
12. aire libre Figura 7 Dimensiones del Conmutador de Transferencia de Energ a Autom tico Y Dimensiones del Compartimiento Dimensiones de Montaje Modelo 01813 AA v Dimensiones del Compartimiento Dimensiones de Montaje Modelo 01814 El compartimiento del conmutador de transferencia se asegura usualmente mediante orificios ya perforados tal como se muestra Conectador autom tico de Bri Manual de Instalaci n y del Propietario Briggs Stratton POWER PRODUCTS Pautas de Montaje El conectador autom tico est encerrado en una caja tipo 3R NEMA que es adecuada para uso en interiores y a la intemperie Las directrices para el montaje de conectador autom tico incluyen Instale el conmutador sobre una estructura de soporte firme y resistente e El interruptor se debe instalar con conexiones m nimas de conduit de fo de hardware de NEMA 3R e Para evitar distorsiones en el conmutador nivele la unidad si es necesario Puede hacerlo colocando arandelas entre el compartimiento del conmutador y la superficie de montaje
13. n que podr a resultar en el da o del equipo Siga los mensajes de seguridad para evitar o reducir los riesgos de heridas e inclusive la muerte El fabricante no puede prever todas las posibles circunstancias que pueden implicar riesgos Por lo tanto las advertencias que aparecen en este manual y las etiquetas y calcoman as adheridas a la unidad no incluyen todas las posibilidades Si aplica un procedimiento m todo de trabajo o t cnica de operaci n no recomendada espec ficamente por el fabricante debe estar seguro de que se trata de una pr ctica segura para usted y para otras personas Tambi n debe asegurarse de que el procedimiento m todo de trabajo o t cnica de operaci n que elija no haga que el conmutador de transferencia se torne inseguro ADVERTENCIA Unicamente los electricistas capacitados pueden intentar instalar este sistema Dicha instalaci n debe cumplir estrictamente con los c digos las regulaciones y las normas correspondientes 27 Conectador autom tico de Briggs amp Stratton Power Products Manual de Instalaci n y del Propietario Briggs Stratton POWER PRODUCTS ADVERTENCIA Pi E Si no hace tierra apropiadamente con un conmutador de transferencia puede hacer que ocurra un electrocutamiento NO toque los alambres pelados o recept culos NO use un conmutador de transferencia con cables el ctricos que est n malgastados rotos pelados o dafiados de cualquier forma NO ma
14. DE COMERCIABILIDAD O IDONEIDAD PARA UN FIN CONCRETO SE LIMITAN A UN A O DESDE LA FECHA DE COMPRA O AL L MITE DE TIEMPO PERMITIDO POR LA LEY QUEDAN EXCLUIDAS TODAS LAS GARANT AS IMPL CITAS QUEDA EXCLUIDA LA RESPONSABILIDAD POR DA OS SECUNDARIOS Y DERIVADOS HASTA EL L MITE PERMITIDO POR LA LEY Algunos pa ses o estados no permiten limitar la duraci n de una garant a impl cita ni excluir o limitar los da os secundarios y derivados Por tanto es posible que las limitaciones y exclusiones mencionadas no sean aplicables en su caso Esta garant a le otorga determinados derechos legales y es posible que tenga otros derechos que pueden variar de un pa s o estado a otro NUESTRO EQUIPO MOTOR LIMPIADORA BOMBA DE GENERADOR SISTEMA GENERADOR CONECTADOR FUERABORDA A PRESI N AGUA PORT TIL DOM STICO No disponible Incluye el conectador si se ha en EE UU SOLDADOR adquirido con el equipo Menos de 10 kW 10 kW m s PER ODO DE GARANT A Uso del consumidor 2 a os 1 a o 1 a o 2 a os 2 a os 3 a os 6 1 an a o E 3 E F A Ales hora Uso comercial ninguno 90 dias 90 dias ninguno ninguno SRE El motor y las bater as de arranque s lo est n cubiertos por la garant a de su fabricante ud 2 a os para todos los productos de consumo en la Uni n Europea Componentes s lo durante el segundo a o para uso del consumidor del generador port til y del sistema generador dom stico Menos de 10 kW fuera de la Uni n Europea El per o
15. GARANTIE VOUS NE POUVEZ PROUVER LA DATE INITIALE DE L ACHAT NOUS UTILISERONS LA DATE DE FABRICATION DU PRODUIT COMME DATE DE REFERENCE POUR DETERMINER LA PERIODE DE GARANTIE A PROPOS DE LA EQUPEMENT GARANTIE Nous acceptons de faire effectuer les r parations couvertes par la garantie et tenons a nous excuser pour tout inconv nient subi Tout agent d un service apr s vente agr peut ex cuter les r parations couvertes par la garantie La plupart des r parations couvertes par la garantie sont trait es automatiquement cependant il arrive parfois que les demandes de service en vertu de la garantie soient non fond es Par exemple la garantie ne couvre pas les dommages caus s a l quipement par une utilisation abusive par un manque d entretien p riodique durant l exp dition la manutention ou l entreposage ou en raison d une installation inad quate De m me la garantie sera annul e si la date de fabrication ou le num ro de s rie appos l quipement a t enlev ou si l quipement a t chang ou modifi Durant la p riode de garantie le distributeur de service apr s vente agr r parera ou remplacera a son gr toute pi ce qui apres examen est trouv e d fectueuse a la suite d une utilisation et d un entretien normaux La pr sente garantie ne couvre pas les r parations et les quipements suivants Usure normale Comme tout autre dispositif m canique les groupes lectrog nes d ext rieur n cessitent l
16. and some states or countries do not allow the exclusion or limitation of incidental or consequential damages so the above limitation and exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country OUR EQUIPMENT OUTBOARD PRESSURE WATER PUMP PORTABLE HOME GENERATOR SYSTEM TRANSFER MOTOR WASHER Nel STAN mine GENERATOR Includes Transfer Switch if sold with equipment SWITCH WELDER Less than 10 KW Less than 10 KW WARRANTY PERIOD Consumer Use 2 years 1 year 1 year 2 years 2 years 3 years or 1 year Commercial Use none 90 days 90 days 1 year 1 year 1500 hours The engine and starting batteries are warranted solely by the manufacturers of those products 2 years for all consumer products in the European Union Parts only on 2nd year for consumer use of Portable Generator and Home Generator System Less than 10 KW outside of European Union dee The warranty period begins on the date of purchase by the first retail consumer or commercial end user and continues for the period of time stated in the table above Consumer use means personal residential household use by a retail consumer Commercial use means all other uses including use for commercial income producing or rental purposes Once equipment has experienced commercial use it shall thereafter be considered as commercial use for purposes of this warranty Equi
17. brica Antes de ponerse en contacto con Briggs and Stratton Power Products en relaci n con el servicio o reparaci n de este conectador tome nota del n mero de modelo y del n mero de serie que figuran en la etiqueta adhesiva de datos de la unidad situada en el interior de la caja A contacto Briggs and Stratton Power Products llame al 1 800 743 41 15 entre las 8 00 AM y las 5 00 PM hora del centro Conectador autom tico de Briggs amp Stratton Power Products Manual de Instalaci n y del Propietario Briggs amp StraHon POWER PRODUCTS NOTAS 33 Briggs Stratton POWER PRODUCTS onectador autom tico de Bri Manual de Instalaci n y del Propietario REPARACION DE AVERIAS Problemo El conectador autom tico no transfiere la conexi n al generador El conectador autom tico no transfiere la conexi n a la red p blica El generador sigue funcionando despu s de que el conectador transfiera la conexi n a la red p blica Las cargas supervisadas acondicionador de aire etc no funcionan cuando se utiliza la red el ctrica Causa El disyuntor del generador est abierto La tensi n del generador no es aceptable El disyuntor de desconexi n de servicio est abierto La tensi n de la red p blica no es aceptable El per odo de enfriamiento del motor Los contactos NC no funcionan correctamente 34 s amp Stratton Power Products REPARACION DE AVER AS Accion
18. entretien p riodiques de certaines pi ces pour fonctionner ad quatement La pr sente garantie ne couvre pas les frais de r paration des pi ces ou des quipements dont la dur e de vie utile a t d pass e la suite d une utilisation normale Installation et entretien La pr sente garantie ne couvre pas les quipements ou les pi ces qui ont fait l objet d une installation ou de modifications et de changements inad quats ou non autoris s d une mauvaise utilisation de n gligence d un accident d une surcharge d emballement d entretien inad quat de r paration ou d entreposage qui selon nous auraient nui la performance et la fiabilit du produit De plus la garantie ne couvre pas l entretien normal tel que le r glage le nettoyage du circuit d alimentation et son obstruction caus e par l accumulation de produits chimiques de salet s de calamine de calcaire etc Exclusions suppl mentaires La pr sente garantie exclut les pi ces qui s usent telles que les raccords rapides les jauges d huile les courroies les joints toriques les filtres les garnitures de pompes etc les pompes ayant fonctionn sans alimentation en eau ou tout dommage ou tout mauvais fonctionnement r sultant d un accident d une utilisation abusive de modifications de changements ou d un entretien inad quat du syst me du gel ou d une d t rioration chimique La garantie du produit ne couvre pas les pi ces accessoires telles que les pi
19. fin du refroidissement de la g n ratrice Le module de commande comprend aussi des voyants rouge et vert indiquant les sources d alimentation disponibles et deux contacts command s par relais pour le contr le des charges critiques externes INSTALLATION D ballage V rification de la Livraison Apr s avoir enlev le carton examinez avec soin les l ments du commutateur de transfert automatique pour tout dommage subi durant l exp dition IMPORTANT Au moment de la livraison si vous remarquez des dommages ou des pi ces manquantes demandez au livreur de noter tous les dommages sur la facture de fret et d apposer sa signature dans l espace r serv cet effet Apr s la livraison si vous remarquez des pi ces manquantes ou des dommages mettez les pi ces endommag es de c t et communiquez avec le transporteur pour conna tre les proc dures de r clamation Les pi ces manquantes ou endommag es ne sont pas garanties Contenu de la Bo te Commutateur de Transfert Automatique e Manuel de d installation et l Utilisateur Guide d installation et d utilisation Dimensions pour l installation Briggs Stratton POWER PRODUCTS La Figure 4 illustre les dimensions physiques ainsi que l emplacement des trous de fixation du bo tier du NEMA 3R commutateur de transfert Ce bo tier convient uniquement l int rieur ext rieur Figure 4 Dimensions du Commutateur de Transfert Automatique
20. infiltrer Prot gez le commutateur en tout temps contre l humidit les poussi res les salet s les peluches le gravier et les vapeurs corrosives La Figure 5 illustre un commutateur de transfert automatique typique Il est recommand d installer le commutateur pr s du compteur de l alimentation de service soit l int rieur ou l ext rieur Discutez des suggestions changements de disposition avec le propri taire avant d entamer le processus d installation du syst me Interconnexions du Cablage d Alimentation Tout le c blage doit tre d un gabarit appropri bien fix et prot g par des conduits Effectuez les raccords suivants entre le commutateur de transfert le panneau de distribution principal l alimentation de service et la g n ratrice Figure 6 l Assurez vous que l alimentation de service est HORS TENSION Raccordez les fils d alimentation de service aux bornes UTILITY CONNECTION du commutateur de transfert 2 Raccordez le neutre de service la borne NEUTRAL du commutateur de transfert Figure 5 Installation Typique d un Interrupteur s amp Stratton Power Products INSTALLATION CAUTION Les fils de basse tension ne peuvent tre install s dans le m me conduit que les fils d alimentation L omission de suivre cet avertissement pourrait entra ner des dommages l quipement et ou son mauvais fonctionnement 3 Raccordez les fils d alimentation du panneau
21. m s informaci n en conectador llame al 1 800 743 4115 entre las 8 00 AM y las 5 00 PM hora del centro Orientaci n para el Propietario Las ilustraciones se aplican a circunstancias t picas y est n destinadas a que usted se familiarice con las opciones de instalaci n disponibles con su conmutador de transferencia Los c digos locales la apariencia y las distancias son los factores fundamentales a tener en cuenta cuando se realiza la negociaci n con el profesional que tendr a su cargo la instalaci n Recuerde que a medida que la distancia del servicio de electricidad existente aumenta se debe tener en cuenta una compensaci n igual en los materiales de cableado Esto es necesario para cumplir con los c digos locales y solucionar ca das en la tensi n el ctrica Los factores antes mencionados tendr n un efecto directo sobre el precio general de la instalaci n del conmutador de transferencia NOTA El instalador debe verificar los c digos locales Y obtener los permisos correspondientes antes de instalar el sistema e Lea y cumpla las instrucciones incluidas en el manual e Siga un programa regular para cuidar y utilizar el conmutador de transferencia seg n se especifica en el manual Responsabilidades del Instalador e Lea y observe las reglas de seguridad que se encuentran en el manual e Leay siga las instrucciones que se encuentran en este manual Consulte toda la normativa nacional y local Descripci
22. n del Equipo Estos conectadores pertenecen a una nueva generaci n destinada a transferir toda la carga de instalaciones residenciales normales La carga se conecta a la red p blica normal o a la alimentaci n dom stica de reserva emergencia El conectador monitoriza las tensiones de la red p blica y del generador y conecta autom ticamente la carga a la fuente de alimentaci n apropiada INSTALACI N Los componentes principales del conectador son un interruptor bipolar de 2 posiciones de contacto una tarjeta de circuito impreso del m dulo de control terminales con fusibles de detecci n de tensi n de la red p blica y cableado de interconexi n El conectador es accionado por un solenoide alimentado desde las entradas de la red p blica o del generador y tiene interruptores de enclavamiento mec nicos y el ctricos adecuados para eliminar la posibilidad de conectar la red p blica a la salida del generador Sus valores nominales son suficientes para conectar toda potencia de la red p blica a la residencia Para la funci n de transferencia hay una palanca de cancelaci n manual La tarjeta de circuito impreso del m dulo de control tiene circuitos activos que detectan las tensiones de la red p blica y del generador Genera una se al para el arranque del generador el conectador la retransferencia cuando se restablece la tensi n en la red p blica y los per odos de enfriamiento del generador La tarjeta de control contie
23. technique d op ration non sp cifiquement recommand e par le fabricant vous devez vous assurer qu elle ne compromet pas votre s curit ni celle des autres Vous devez galement vous assurer que la proc dure la m thode de travail ou la technique d op ration que vous choisissez ne rende pas la commutateur de transfert dangereuse AVERTISSEMENT Seuls les lectriciens et les techniciens en combustibles gazeux qualifi s peuvent proc der l installation de ce syst me laquelle doit se conformer strictement aux codes aux normes et aux r glementations applicables Commutateur de transfert automatique Briggs amp Stratton Power Products Guide d installation et d utilisation Briggs amp Stratton POWER PRODUCTS A NE PAS relier le commutateur de transfert la terre risque de provoquer des lectrocutions NE touchez PAS les fils d nud s ou les bo tiers N utilisez PAS le commutateur de transfert avec des cordons lectriques us s effiloch s ou d nud s ou ab m s de quelque sorte que ce soit NE manipulez PAS les cordons d alimentation lorsque vous tes debout dans l eau pieds nus ou avec les mains ou les pieds humides Si vous devez travaillez autour d une unit alors qu elle est en marche placez vous sur une surface s che isol e afin de r duire les risques de choc lectrique NE laissez PAS des personnes non qualifi es ou des enfants se servir ou r parer le commutateur de transfert En ca
24. 0 Hz Intensit de d faillance nominale 25 000 Amp res Sym triques RMS Poids aae nae EEE EAE sets 15 4 kg 34 Ib Si vous Devez Communiquer avec l Usine Avant de contacter Briggs and Stratton Power Products au sujet de l entretien ou de la r paration de ce commutateur de transfert veuillez noter les num ros de mod le et de s rie indiqu s sur le d calque appos sur l unit ou l int rieur de celle ci Pour contacter Briggs and Stratton Power Products veuillez appeler au 800 743 4115 de 8 h 17 h HNC D PANNAGE Commutateur de transfert automatique Briggs amp Stratton Power Products NY D PANNAGE PROBLEMES Le commutateur de transfert automatique ne transf re pas a la g n ratrice Le commutateur de transfert automatique ne transf re pas l alimentation de service La g n ratrice continue de fonctionner apr s que le commutateur eut transf r l alimentation de service Les charges r glables climatiseur etc ne fonctionnent pas sous l alimentation de service Guide d installation et d utilisation Le disjoncteur de la g n ratrice est ouvert La tension de la g n ratrice n est pas ad quate Le disjoncteur de l alimentation de service est ouvert La tension de l alimentation de service n est pas ad quate La p riode de refroidissement n a pas t compl t e Les contacts normalement ferm s ne fonctionnent pas correctement 23 Briggs Stratton
25. FONCTIONNEMENT 4 4 0 22 GARANTIE 25 n REGLES DE S CURIT REGLES DE S CURIT Le symbole indiquant un message de s curit est accompagn d un mot indicateur DANGER ATTENTION AVERTISSEMENT d un message illustr et ou d un message de s curit visant vous avertir des dangers DANGER indique un danger qui s il n est pas vit provoquera des blessures graves voire fatales ANERTISSEMENT indique un danger qui s il n est pas vit peut provoquer des blessures graves voire fatales ATTENTION indique un danger qui s il n est pas vit peut provoquer des blessures mineures ou l g res Le mot ATTENTION lorsqu il est utilis sans le symbole d alerte indique une situation pouvant endommager l quipement Suivez les messages de s curit pour viter ou r duire les risques de blessures ou de mort Ceci est la s ret le symbole vif Il est utilis pour vous alerter aux dangers de blessure personnels potentiels Ob ir tous messages de s ret qui suivent ce symbole viter la blessure ou la mort possibles Le fabriquant ne peut anticiper toutes les circonstances potentielles pouvant comporter un danger Par cons quent les avertissements contenus dans le pr sent manuel ainsi que les plaques et les d calques appos s sur l unit n englobent pas toutes les possibilit s Si vous utilisez une proc dure une m thode de travail ou une
26. Installation amp Owner s Manual Guide d Installation et d Utilisation Manual de Instalaci n y del Propietario Questions Help is just a moment away Preguntas La ayuda es justa un momento lejos Vous avez des questions Vous n avez pas besoin d aller loin pour trouver de l aide Call Transfer Switch Helpline Llamada Linea Directa de Ill MM sous ni Interruptor de Transferencia B Appelez Ligne Directe de Commutateur de Transfert 1 800 743 4115 M F 8 5 CT 1 i Web www briggspowerproducts com p a A s 100 Amp 200 Amp lt Ssriggs stratton i s POWER PRODUCTS Automatic Transfer Switch Controls by Eaton s Cutler Hammer c i US Models 01813 0 amp 01814 0 1008 LISTED Part No 192711GS Rev 11 25 03 Briggs Stratton Power Products Automatic Transfer Switch Briggs amp Stratton Installation and Owner s Manual POWER PRODUCTS TABLE OF CONTENTS TABLE OF CONTENTS 2 TESTING THE AUTOMATIC TRANSFER SWITCH 8 SAFETY RULES 4 exert ERI RR EE 3 Automatic Sequence 8 INTRODUCTION eccere sica 4 Utility False rp 8 For the Home or Business Owner 4 Engine Warm Up 8 For the Installing Dealer Contractor 4 A ape se sde sas ari 8 Owner Orientation 4 Utility Pick p wis circa i 8 Installer Responsibilities 4 R transfer vessie w
27. NNECTION 2 Connectutility neutral to the transfer switch NEUTRAL terminal Figure 2 A Typical Transfer Switch Mounting INSTALLATION CAUTION Low voltage wire cannot be installed in same conduit as power voltage wiring Failure to follow above warning could cause damage and or malfunction of equipment 3 Connect main distribution panel power leads to transfer switch terminals marked LOAD CONNECTION 4 Connect main distribution panel neutral lead to transfer switch NEUTRAL terminal 5 Connect generator power supply leads from the generator s control panel to transfer switch terminals marked GENERATOR CONNECTION 6 Connect generator Neutral from the control panel to the transfer switch NEUTRAL terminal 7 Connect generator GND from the control panel to the transfer switch GND terminal 8 Connect main distribution panel GND to the transfer switch GND terminal 9 Connect generator utility 240 VAC terminals to transfer switch utility 240 VAC terminals 10 Terminal strip on control module in transfer switch has four connections for customer use There are two sets of Normally Closed contacts available They will be activated when generator power is required These can be used for supervisory control of large connected loads on generator for example disconnecting air conditioner water heater etc or an alarm source II Tighten all wire connect
28. NOT qualify for emergency standby as defined by NFPA 70 NEC Briggs and Stratton Power Products BSPP has made every effort to provide for a safe streamlined and cost effective installation Each installation is unique it is impossible to know of and advise of all conceivable procedures and methods by which installation might be achieved We could not know of possible hazards and or the results of each method or procedure For these reasons Only licensed electrical contractors should install transfer switches Installations must strictly comply with all applicable federal state and local codes standards and regulations Your BSPP Transfer Switch is supplied with this combined Installation and Owner s Manual This is an important document and should be retained by the owner after the installation has been completed Every effort has been expended to make sure that the information in this manual is both accurate and current However the manufacturer reserves the right to change alter or otherwise improve the system at any time without prior notice For the Home or Business Owner To help you make informed choices and communicate effectively with your installation contractor s Read and understand the Owner Orientation Section of this manual BEFORE contracting or starting your transfer switch installation INSTALLATION To arrange for proper installation contact the store at which you purchased your BSPP Transfer S
29. NUNCA instale el conmutador en un lugar en el cual pueda producirse el goteo de alguna sustancia corrosiva en el compartimiento e Proteja permanentemente al conmutador contra humedad excesiva polvo suciedad pelusas arenilla para construcci n y vapores corrosivos En la Figura 8 se ilustra un Conmutador de transferencia de energ a autom tico t pico Lo mejor es montarlo cerca del contador de la compa a el ctrica en el interior o en el exterior Antes de iniciar el proceso de instalaci n del sistema analice los cambios y sugerencias de diagramaci n con el propietario de la unidad Interconexiones de Cableado de Energ a Todo el cableado debe tener el tama o adecuado y debe estar correctamente soportado Tambi n debe estar protegido mediante un conducto Realice las conexiones siguientes entre el conectador el panel principal de distribuci n la red p blica y el generador Figura 9 de la p gina siguiente I Aseg rese de que la tensi n de la red p blica no est aplicada Conecte los terminales de alimentaci n de la red p blica a los terminales del conectador con la marca UTILITY CONNECTION conexi n de la red p blica 2 Conecte el neutro de la red p blica al terminal del conectador con la marca NEUTRAL neutro Figura 8 Montaje del Conmutador T pico de s amp Stratton Power Products INSTALACI N PRECAUCION Los cables de baja tensi n no se pueden instalar en el mismo
30. R DOS 29 Modelo 01813 a o erro e race 32 Inspecci n al Momento de la Entrega 29 Modelo 01814 32 Contenido de la Caja 29 Si Llamara la F brica ese ru RR Re RR 32 Dimensiones de Montaje 29 SS iii rie e ia 33 amp 35 Pautas de Montaje 30 REPARACION DE AVER AS 34 Interconexiones de Cableado de Energ a 30 31 DIAGRAMAS VISTAS AMPLIADAS LISTAS DE PIEZAS 10 13 SISTEMA OPERACI N oia are cadenas canes 32 GARANTIA 25cm sida a 36 26 INSTRUCCIONES DE SEGURIDAD ste es el s mbolo de alerta de seguridad Sirve para advertir al usuario de un posible riesgo para su integridad f sica Siga todos los mensajes de seguridad que figuren despu s de este s mbolo para evitar lesiones o incluso la muerte El s mbolo de alerta de seguridad es usado con una palabra PELIGRO ADVERTENCIA PRECAUCI N un mensaje por escrito o una ilustraci n para alertarlo acerca de cualquier situaci n de peligro que pueda existir PELIGRO indica un riesgo el cual si no se evita causar la muerte o una herida grave ADVERTENCIA indica un riesgo el cual si no se evita puede causar la muerte o una herida grave PRECAUCI N indica un riesgo el cual si no se evita puede causar heridas menores o moderadas PRECAUCI N cuando se usa sin el s mbolo de alerta indica una situaci
31. T If loss or damage is noted at time of delivery have the person s making delivery note all damage on the freight bill and affix his signature under the consignor s memo of loss or damage If loss or damage is noted after delivery contact the carrier for claim procedures Missing or damaged parts are not warranted Shipment Contents Automatic Power Transfer Switch Installation and Owner s Manual Briggs amp Stratton Power Products Automatic Transfer Switch Installation and Owner s Manual Briggs amp Stratton POWER PRODUCTS Mounting Dimensions Figure depicts the physical size and mounting hole locations of the NEMA 3R automatic transfer switch enclosure This enclosure is suitable for indoor outdoor use Figure Automatic Power Transfer Switch Dimensions v Enclosure Dimensions Mounting Dimensions Model 01813 v Enclosure Dimensions Mounting Dimensions Model 01814 The transfer switch enclosure is commonly secured through the predrilled holes as shown Briggs amp Stratton Power Products Aut
32. a el control de supervisi n de grandes cargas conectadas al generador o como una fuente de alarma II Apriete de todas las conexiones de los cables y elementos de fijaci n al par adecuado Panel del Disyuntor Principal Conmutador de Transferencia Seccionador O de servicio Contador de vatios hora Generador Conectador autom tico de Briggs amp Stratton Power Products Manual de Instalaci n y del Propietario Briggs amp StraHon POWER PRODUCTS MODELO 01813 Conexi n de la compa a proveedora de E Contactos electricidad Normalmente Cerrados Conexi n al T Conexi n generador de la Carga Orejetas de 64 Terminales conexi n a NEUTRAL o j neutro tierra GND Panel de Distribuci n Principal Principal conductora NEUTRAL neutro Barra conductora L Ground tierra Al Generador A la Red P blica MODELO 01814 Conexi n de la compa a I proveedora de F Contactos electricidad Normalmente Cerrados Conexi n Conexi n al de la Carga generador Orejetas de Terminales conexi n a NEUTRAL tierra GND j neutro Panel de Distribuci n Principal ESTER Taling 600 voil 2 amp i Barra Principal conductora NEUTRAL neutro N rra conductora Al Generador a4 Gr
33. al YF rre de Mise Vers la G n ratrice la Terre 21 Commutateur de transfert automatique Bri Guide d installation et d utilisation Briggs amp Stratton POWER PRODUCTS FONCTIONNEMENT Pour actionner le transfert automatique suivez la proc dure d crite ci dessous I R glez sur On l interrupteur de d branchement de l alimentation de service qui transmet l alimentation de service au commutateur de transfert 2 R glez le disjoncteur principal de la g n ratrice sur On Installez le fusible de 15 amp res dans le panneau de commande de la g n ratrice 4 R glez l interrupteur AUTO OFF MANUAL de la g n ratrice sur AUTO Le syst me est maintenant en mode de fonctionnement automatique MISE L ESSAI DU COMMUTATEUR DE TRANSFERT AUTOMATIQUE R glez l interrupteur de d branchement alimentant le commutateur de transfert sur Off La s quence automatique commencera Pour revenir l alimentation de service r glez l interrupteur de d branchement sur On S quence Automatique Panne de l alimentation de service Le capteur de tension de service d tecte la chute de la tension de service sous 70 pourcent de la tension nominale La s quence de d marrage du moteur commence apr s un d lai de 6 secondes
34. al uso la falta de mantenimiento el transporte la manipulaci n el almacenamiento o la instalaci n inadecuados De manera similar la garant a quedar anulada si se ha borrado la fecha de fabricaci n o el n mero de serie del equipo o si el equipo ha sido alterado o modificado Durante el per odo de garant a el distribuidor de servicio autorizado podr reparar o sustituir a su libre elecci n cualquier pieza que previa inspecci n sea defectuosa en condiciones normales de uso y servicio Esta garant a no cubre las reparaciones y equipos que se detallan a continuaci n Desgaste normal Al igual que cualquier otro aparato mec nico los equipos de uso en exteriores necesitan piezas y mantenimiento peri dicos para funcionar correctamente Esta garant a no cubre las reparaciones cuando el uso normal haya agotado la vida til de una pieza concreta del equipo Instalaci n y mantenimiento Esta garant a no cubre los equipos ni las piezas cuya instalaci n sea incorrecta o no haya sido autorizada ni aquellos que hayan sido objeto de cualquier tipo de alteraci n mal uso negligencia accidente sobrecarga exceso de velocidad o mantenimiento reparaci n o almacenamiento inadecuados que a nuestro juicio haya afectado negativamente a su funcionamiento y su fiabilidad La garant a tampoco cubre el mantenimiento normal como los ajustes y la limpieza o la obstrucci n del sistema de combusti n debido a materias qu micas suciedad carb
35. ateur de transfert convient UNIQUEMENT aux g n ratrices de secours r sidentielles Briggs amp Stratton Ce produit est con u pour tre utilis comme groupe lectrog ne optionnel fournissant une source d lectricit alternative et pour desservir des charges comme le chauffage les syst mes de r frig ration et les syst mes de communication qui lorsqu ils sont arr t s durant une panne d lectricit peuvent causer des inconforts ou autre Ce produit ne se qualifie pas comme groupe lectrog ne d urgence tel que d fini par la NFPA 70 NEC La soci t Briggs amp Stratton Power Products BSPP a tout fait pour fournir un commutateur de transfert dont l installation soit s curitaire facile et conomique Comme chaque installation est unique il est impossible de conna tre et de recommander une marche a suivre pr sentant toutes les m thodes et consignes d installation possibles Briggs et Stratton ignore galement les dangers et ou les r sultats potentiels de chaque m thode ou proc dure C est pourquoi Seuls des entrepreneurs en lectricit qualifi s devraient proc der a l installation des commutateur de transfert Toute installation doit tre conforme tous codes de s curit applicables ainsi qu aux normes et la r glementation de l industrie Votre commutateur de transfert BSPP est livr avec le pr sent Guide d installation et d utilisation Ce guide est un document important conservez le apr s av
36. conducto que los cables de suministro de energ a Si no se respeta esta indicaci n pueden producirse da os y o el equipo puede funcionar incorrectamente 3 Conecte los terminales de alimentaci n de la red p blica a los terminales del conectador con la marca LOAD CONNECTION conexi n de la carga 4 Conecte el neutro del panel principal de distribuci n al terminal del conectador con la marca NEUTRAL neutro 5 Conecte los terminales de alimentaci n del generador desde el panel de control del generador hasta los terminales del conectador con la marca GENERATOR CONNECTION conexi n del generador 6 Conecte el neutro del generador desde el panel de control hasta el terminal del conectador con la marca NEUTRAL 7 Conecte el terminal GND tierra desde el panel de control hasta el terminal del conectador con la marca GND tierra 8 Conecte el terminal GND tierra desde el panel de distribuci n principal hasta el terminal del conectador con la marca GND tierra 9 Conecte los terminales de detecci n de tensi n de la red p blica del generador a los terminales de detecci n de tensi n de la red p blica del conectador 10 La regleta de terminales del m dulo de control del conectador tiene 4 conexiones para uso del cliente El sistema dispone de dos juegos de contactos normalmente cerrados que se activan cuando se necesita alimentaci n del generador Estos contactos se pueden utilizar par
37. de distribution principal aux bornes LOAD CONNECTION du commutateur de transfert 4 Raccordez le fil neutre du panneau de distribution principal la borne NEUTRAL du commutateur de transfert 5 Raccordez les fils d alimentation du panneau de commande de la g n ratrice aux bornes GENERATOR CONNECTION du commutateur de transfert 6 Raccordez le neutre du panneau de commande de la g n ratrice la borne NEUTRAL du commutateur de transfert 7 Raccordez le GND du panneau de commande de la g n ratrice la borne GND du commutateur de transfert 8 Raccordez le GND du panneau de distribution principal la borne GND du commutateur de transfert 9 Raccordez les bornes de d tection de l alimentation de service de la g n ratrice aux bornes de d tection de l alimentation du commutateur de transfert 10 La barrette de raccordement du module de commande du commutateur de transfert comporte quatre raccords l usage du client Deux ensembles de contacts normalement ferm s sont disponibles ils sont activ s lorsque la g n ratrice est mise en marche lls peuvent servir contr ler d importantes charges branch es la g n ratrice ou une alarme Il Serrez au couple appropri tous les raccords de fils et attaches O Watt Panneau du disjoncteur principal Commutateur de Transfert heurem tre D branchement de l alimentation de service
38. do de garant a comienza en la fecha de compra del primer consumidor o usuario comercial final y se prolonga durante el tiempo especificado en la siguiente tabla Uso del consumidor significa uso dom stico personal por parte de un consumidor final Uso comercial significa cualquier otro uso incluidos los usos con fines comerciales de generaci n de ingresos o alquiler Una vez que el equipo se haya usado con fines comerciales se considerar como equipo de uso comercial a efectos de esta garant a Los equipos utilizados para suministrar energ a en sustituci n de un servicio p blico no pueden acogerse a esta garant a Las limpiadoras a presi n con alimentaci n el ctrica para fines comerciales no est n cubiertas por la garant a NO ES NECESARIO REGISTRAR LA GARANT A PARA OBTENER SERVICIO DE BRIGGS amp STRATTON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANT A ACERCA DE LA EQUIPO GARANT A Esperamos que disfrute de nuestra garant a y le pedimos disculpas por las molestias causadas Cualquier distribuidor de servicio autorizado puede llevar a cabo reparaciones en garant a La mayor a de las reparaciones en garant a se gestionan normalmente pero algunas veces la solicitud de servicio en garant a puede no ser procedente Por ejemplo la garant a no ser v lida si el equipo presenta da os debidos al m
39. eh 8 Equipment Description 5 Engine Cool Down 8 INSTALLATION 2er Reni eal i a 5 Specifications csc se 4 ns err err herd hen 8 Unpacking accionar ne 5 Model 01813 RR 8 Delivery Inspection 5 Model 01814 4 2002646002506266 de ehh 8 Shipment Contents 5 When Calling The Factory 8 Mounting Dimensions 5 TROUBLESHOOTING npe 9 Mounting Guidelines 6 DIAGRAMS EXPLODED VIEWS PARTS LISTS 10 13 Power Wiring Interconnections 6 7 NOTES diiniita a la sica 14 SYSTEM OPERATION 4453 cer Ree hn enn 8 WARRANTY ecce RbROSEER RE riadas 15 MO SAFETY RULES SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death The safety alert symbol is used with a signal word DANGER CAUTION WARNING a pictorial and or a safety message to alert you to hazards DANGER indicates a hazard which if not avoided will result in death or serious injury WARNING indicates a hazard which if not avoided could result in death or serious injury CAUTION indicates a hazard which if not avoided might result in minor or moderate injury CAUTION when used without the alert symbol indicates a situation that could result in equipm
40. empo fr o Transferencia Las transferencias de alimentaci n desde la red p blica a la alimentaci n de reserva se producen cuando la tensi n del equipo de reserva est por encima de los niveles especificados El tiempo m nimo de funcionamiento del motor despu s de la transferencia es de 4 minutos Recuperaci n de la Red P blica El nivel de recuperaci n de la tensi n es el 80 de la tensi n nominal Retransferencia Retransferencia de la alimentaci n de reserva a la alimentaci n de la red p blica 10 segundos despu s de que la tensi n de la red p blica se sit e por encima del nivel de recuperaci n 32 s amp Stratton Power Products Enfriamiento del Motor El motor funcionar durante 60 segundos despu s de producirse la retransferencia Especificaciones UL 1008 List Conectador Modelo 01813 Carga maxima circuito desde el centro de carga 100 A Tensi n nominal c a 250V Pol yr od 2 Frecuencia 50 60 Hz Valor nominal de la corriente 22 000 Amperios Eficaces Sim trica conexi n a tierra PESO pp 21 Ibs Modelo 01814 Carga maxima circuito desde el centro de carga 200A Tensi n nominal c a 250V POlOS incitan ari ia e 2 FFECUENCIA s cs et ener mere rw 50 60 Hz Valor nominal de la corriente 25 000 Amperios Eficaces Sim trica conexi n a tierra Si Necesita Llamar a F
41. ent damage Follow safety messages to avoid or reduce the risk of injury or death The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all inclusive lf you use a procedure work method or operating technique that the manufacturer does not specifically recommend you must satisfy yourself that it is safe for you and others You must also make sure that the procedure work method or operating technique that you choose does not render the transfer switch unsafe Only qualified electricians should attempt installation of this system which must strictly comply with applicable codes standards and regulations Briggs amp Stratton Power Products Automatic Transfer Switch Installation and Owner s Manual Briggs Stratton POWER PRODUCTS WARNING Failure to properly ground transfer switch can result in electrocution DO NOT touch bare wires or receptacles DO NOT use transfer switch with worn frayed bare or otherwise damaged wiring DO NOT handle electrical cords while standing in water while barefoot or while hands or feet are wet If you must work around a unit while it is operating stand on an insulated dry surface to reduce shock hazard DO NOT allow unqualified persons or children to operate or service transfer switch In case of an accident caused by electrical shoc
42. familiariser avec les diff rentes options d installation de votre commutateur de transfert dont vous disposez Au moment de n gocier avec un installateur professionnel il faudra tenir compte des facteurs suivants les codes de s curit locaux l apparence et les distances Souvenez vous que plus grandes sont les distances entre le groupe lectrog ne et le service lectrique existant ainsi que l alimentation plus il faudra faire des compensations dans les mat riaux et le c blage Ces modifications sont n cessaires pour vous conformer aux codes de s curit locaux et pour surmonter les chutes de tension Les facteurs mentionn s ci dessus auront une incidence directe sur le prix total de l installation de votre commutateur de transfert REMARQUE Votre installateur est tenu de v rifier les codes locaux ET d obtenir les permis requis avant de proc der l installation du syst me Vous devez lire et suivre les instructions indiqu es dans le manuel tablissez un programme de soins et d utilisation r gulier de votre commutateur de transfert tel qu indiqu dans le manuel Responsabilit s de l installateur Vous devez lire et respecter les r gles de s curit d crites dans le manuel e Vous devez lire et suivre les instructions indiqu es dans le pr sent le manuel e V rifiez tous les codes f d raux provinciaux et locaux INSTALLATION Commutateur de transfert automatique Briggs amp Stratton Power P
43. iales aplicables Su conectador BSPP se suministra con este Manual de Instalaci n y del Propietario combinado Se trata de un documento importante que debe ser conservado por el propietario despu s de haber terminado la instalaci n Se han tomado todos los recaudos posibles para asegurar que la informaci n incluida en este manual sea correcta y est actualizada Sin embargo los fabricantes se reservan el derecho de cambiar alterar o mejorar el sistema de cualquier otra manera y en cualquier momento sin previo aviso Para el Propietario Comercial o Dom stico Para que pueda tomar decisiones fundamentadas y lograr una comunicaci n efectiva con el o los contratistas de instalaci n Lea y comprenda la secci n de este manual denominada Orientaci n para el Propietario ANTES de contratar o iniciar la instalaci n de su conmutador de transferencia Para coordinar y organizar una instalaci n adecuada consulte al comercio en el cual adquiri su conmutador de transferencia Briggs 8 Stratton Power Products a su agente de ventas o a la compa a proveedora de electricidad La garant a del conmutador de transferencia se ANULA si la instalaci n del sistema no est a cargo de profesionales especializados en electricidad certificados 28 s amp Stratton Power Products INSTALACION Para el Agente de Ventas Contratista que Realiza la instalacion Consulte los aspectos de la instalaci n con un inspector Si necesita
44. ions fasteners to proper torque O Disconnect Watt Service Main Breaker Panel Hourmeter Transfer Switch y Generator INSTALLATION Briggs amp Stratton Power Products Automatic Transfer Switch Installation and Owner s Manual Briggs amp StraHon POWER PRODUCTS MODEL 01813 Utility BE Normally Connection Closed Contacts Generator Load Connection Mida LT Connection Neutral D Terminal Ground Lug Main Distribution Pane ERES Neutral Bus 4 To Generator Ground Bus To Utility Power MODEL 01814 Utility MN x Normally Connection ll j Closed Contacts Generator Load Connection LA Connection Neutral L Terminal Ground Lug Main Distribution Pane peace it ai Neutral Bus
45. is 80 percent of nominal voltage Retransfer Retransfer from standby to utility supply 10 seconds after utility voltage supply is above pickup level Engine Cool Down Engine will run for 60 seconds after retransfer Specifications UL 1008 Listed Transfer Switch Model 01813 Maximum Load Circuit from Load Center 100 Amps Rated AC Voltage 250 Volts Poles risi ately A4 3984 2 Frequency 4 50 60 Hz Fault Current Rating 22 000 RMS Symmetrical Amperes Supervisory Contacts Rating 5 Amp 125 Volt AC Weight 21 lbs Model 01814 Maximum Load Circuit from Load Center 200 Amps Rated AC Voltage 250 Volts POLES oir 2 Frequency 50 60 Hz Fault Current Rating 25 000 RMS Symmetrical Amperes Supervisory Contacts Rating 5 Amp 125 Volt AC When Calling the Factory Before contacting Briggs and Stratton Power Products regarding service or repair of this transfer switch obtain the Model Number and Serial Number from the unit data decal located on or inside the case To contact Briggs and Stratton Power Products call 1 800 743 41 15 between 8 00 AM and 5 00 PM CT TROUBLE Briggs amp Stratton Power Products Automatic Transfer Switch SHOOTING Installation and Owner s Manual Briggs Stratton POWER PRODUCTS Problem Cause Correction Automatic transfer witch do s Generator breaker open l Reset generato
46. ivos conectados ap guelos y abra sus interruptores o quite sus fusibles Conectador autom tico de Bri Manual de Instalaci n y del Propietario Briggs Stratton POWER PRODUCTS INTRODUCCI N Muchas gracias por comprar un conectador autom tico de Briggs amp Stratton Este producto est pensado para utilizarlo como un sistema de reserva dom stico opcional que proporciona una fuente alternativa de energ a el ctrica con capacidad para alimentar cargas tales como sistemas de calefacci n y refrigeraci n y sistemas de comunicaciones que cuando dejan de funcionar a causa de una interrupci n de la alimentaci n el ctrica de la red pueden producir incomodidades o problemas Este producto no pertenece a la categor a de reserva de emergencia seg n lo definido por la norma NFPA 70 NEC Briggs and Stratton Power Products BSPP ha hecho todo lo posible para lograr una instalaci n segura eficiente y rentable Como cada instalaci n es nica es imposible conocer e informar acerca de todos los procedimientos y m todos mediante los cuales se puede realizar la instalaci n Tampoco es posible conocer los riesgos o resultados potenciales de cada m todo o procedimiento Por todo lo expuesto La instalaci n de los conmutador de transferencia debe estar a cargo de contratistas especializados en electricidad sin excepciones Las instalaciones deben cumplir estrictamente con todos los c digos regulaciones y normas industr
47. k immediately shut down the source of electrical power and contact local authorities Avoid direct contact with the victim CAUTION Improper treatment of transfer switch can damage it and shorten its life Use transfer switch only for intended uses If you have questions about intended use ask dealer or contact Briggs and Stratton Power Products DO NOT expose transfer switch to excessive moisture dust dirt or corrosive vapors Despite the safe design of the transfer switch operating this equipment imprudently neglecting its maintenance or being careless can cause possible injury or death Remain alert at all times while working on this equipment NEVER work on the equipment when you are physically or mentally fatigued If connected devices overheat turn them off and turn off their circuit breaker fuse Briggs amp Stratton Power Products Automatic Transfer Switch Installation and Owner s Manual Briggs Stratton POWER PRODUCTS INTRODUCTION Thank you for your purchase of this Briggs amp Stratton Power Products Automatic Transfer Switch This product is intended for use with Briggs amp Stratton Home Standby Generator sets ONLY This is an optional home standby system which provides an alternate source of electric power and to serve loads such as heating refrigeration systems and communication systems that when stopped during any power outage could cause discomfort or the like This product DOES
48. n cal etc Otras exclusiones Tambi n quedan excluidos de esta garant a el desgaste de los art culos tales como conectores medidores de aceite correas juntas t ricas filtros juntas de bombas etc las bombas que se hayan hecho funcionar sin agua y los da os derivados de accidentes uso indebido modificaciones alteraciones servicio inadecuado congelaci n o deterioro qu mico Los accesorios tales como pistolas mangueras varillas y boquillas quedan excluidos de la garant a del producto Tambi n se excluyen los equipos usados o reacondicionados y los destinados a demostraciones los equipos utilizados como fuente principal de energ a en lugar de un servicio p blico y los equipos sanitarios destinados al mantenimiento de las constantes vitales BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WI EE UU I 0 2 484710615817
49. ne tambi n luces rojas y verdes que indican las fuentes de alimentaci n disponibles y dos contactos accionados por rel que proporcionan el control de supervisi n de cargas cr ticas externas INSTALACI N Desempaque Inspecci n al Momento de la Entrega Luego de retirar la caja inspeccione cuidadosamente el los componentes del conmutador de transferencia de energ a autom tico para detectar cualquier da o que pudiera haber ocurrido durante el traslado IMPORTANTE Si en el momento de la entrega se detecta alguna p rdida o da o solicite a la persona o personas encargadas de la entrega que dejen debida constancia en la nota de entrega y que firmen debajo de la nota del consignador donde se informa acerca de la p rdida o da o Si la p rdida o el da o se detecta despu s de la entrega separe los materiales da ados y p ngase en contacto con el transportista para llevar a cabo los procedimientos de reclamo Las piezas perdidas o da adas no est n garantizadas Contenido de la Caja Conmutador de transferencia de energia autom tico e Manual de instalaci n y propietario Conectador autom tico de Briggs amp Stratton Power Products Manual de Instalaci n y del Propietario Briggs amp Stratton POWER PRODUCTS Dimensiones de Montaje La Figura 7 muestra el tama o f sico y las ubicaciones de los orificios de montaje del compartimiento del conmutador de transferencia Este compartimiento es para uso en interiores o
50. neje el cables el ctricos mientras est parado en agua descalzo o cuando las manos y los pies est n mojados Si fuera necesario realizar trabajos en cercan as de la unidad mientras est en funcionamiento p rese sobre una superficie seca y aislada para reducir los riesgos de una descarga NO permita que personas descalificadas o nifios operen o sirvan al conmutador de transferencia En caso de que se produzca un accidente causado por una descarga el ctrica cierre inmediatamente la fuente de energ a el ctrica y contacta administraci n local Evite el contacto directo con la v ctima PRECAUCION El tratamiento inadecuado del conmutador de transferencia puede da arlo y acortar su vida productiva Use el conmutador de transferencia solamente con la finalidad para el cual fue dise ado Si usted tiene alguna pregunta acerca de las finalidades de uso del generador preg ntele a su concesionario o contacte a Briggs and Stratton Power Products NO exponga al conmutador de transferencia a una humedad excesiva polvo suciedad o vapores corrosivos A pesar del dise o seguro del conmutador de transferencia si se Opera este equipo en forma imprudente si no se cumple con el mantenimiento o si se act a con descuido se pueden producir lesiones o la muerte Permanezca siempre alerta cuando trabaje con este equipo NUNCA trabaje con este equipo si se siente cansado f sica o mentalmente Si se calientan excesivamente los disposit
51. oir compl t l installation Tout a t fait pour s assurer que les renseignements contenus dans le pr sent guide soient exacts et jour Toutefois le fabriquant se r serve le droit de changer de modifier ou encore d am liorer le syst me en tout temps et ce sans pr avis Au Propri taire R sidentiel ou Commercial Afin de vous aider faire des choix avis s et communiquer efficacement avec l entrepreneur qui proc dera l installation Veuillez lire avec soin la section Conseils au propri taire dans le pr sent guide avant de contracter un entrepreneur ou de commencer l installation de votre commutateur de transfert Pour assurer une installation ad quate veuillez contacter le magasin qui vous a vendu votre commutateur de transfert Briggs amp Stratton Power Products votre d taillant ou votre fournisseur de services d lectricit Si l installation du commutateur de transfert n est pas effectu e par des professionnels certifi s en lectricit la garantie sera ANNULEE s amp Stratton Power Products INSTALLATION Au D taillant ou l Entrepreneur Proc dant l installation T l phonez un inspecteur de votre localit si vous avez des questions concernant l installation Si vous avez besoin de renseignements suppl mentaires veuillez appeler au 800 743 4115 de 8 h 17 h HNC Conseils au Propri taire Les illustrations se rapportent des cas typiques et ont pour but de vous
52. omatic Transfer Switch Installation and Owner s Manual Briggs Stratton POWER PRODUCTS Mounting Guidelines The Automatic Transfer Switch is enclosed in a NEMA Type 3R enclosure suitable for indoor outdoor use Guidelines for mounting the Automatic Transfer Switch include Install the switch on a firm sturdy supporting structure The switch must be installed with minimum NEMA 3R hardware for conduit connections To prevent switch contact distortion level and plumb the enclosure This can be done by placing washers between the switch enclosure and the mounting surface e NEVER install the switch where any corrosive substance might drip onto the enclosure Protect the switch at all times against excessive moisture dust dirt lint construction grit and corrosive vapors A typical installation of the Automatic Power Transfer Switch is depicted in Figure 2 It is best if it is mounted near the utility meter either inside or outside Discuss layout suggestions changes with the owner before beginning the system installation process Power Wiring Interconnections All wiring must be the proper size properly supported and protected by conduit Complete the following connections between the transfer switch main distribution panel utility power and generator Figure 3 on next page I Ensure utility power is turned OFF Connect utility power supply leads to transfer switch terminals marked UTILITY CO
53. ound tierra 3l Conectador autom tico de Bri Manual de Instalaci n y del Propietario Briggs Stratton POWER PRODUCTS SISTEMA FUNCIONAMIENTO Para seleccionar el funcionamiento autom tico del conectador haga lo siguiente I Ponga el seccionador de servicio que env a tensi n de la red p blica al conectador en la posici n On conectado 2 Ponga el disyuntor principal del generador en la posici n On conectado 3 Instale el fusible de 15 A en el panel de control del generador Ponga el interruptor AUTO OFF MANUAL autom tico desconectado manual en la posici n AUTO El sistema estar entonces en el modo de funcionamiento autom tico PRUEBA DEL CONECTADOR AUTOM TICO Ponga el seccionador de servicio que alimenta el conectador en la posici n Off desconectado Se realizar la secuencia autom tica correspondiente Para volver a la alimentaci n desde la red p blica ponga el seccionador de servicio en la posici n ON conectado Secuencia Autom tica Fallo de la Red P blica El sensor de tensi n de la red p blica detecta cu ndo esta tensi n est por debajo del 70 de la nominal Tras un retardo de 6 segundos se inicia la secuencia de arranque del motor Calentamiento del Motor Retardo de tiempo para permitir el calentamiento del motor antes de la transferencia fijado en 20 segundos 50 segundos con paquete opcional para ti
54. owerproducts com afin de trouver un distributeur de service apr s vente agr dans votre r gion IL N EXISTE AUCUNE AUTRE GARANTIE EXPRESSE LES GARANTIES IMPLICITES INCLUANT CELLES DE QUALIT MARCHANDE ET D ADAPTATION UN USAGE PARTICULIER SONT LIMIT ES UNE P RIODE D UN AN PARTIR DE LA DATE D ACHAT OU JUSQU LA LIMITE PERMISE PAR LA LOI TOUTE GARANTIE IMPLICITE EST EXCLUE LA RESPONSABILIT POUR DOMMAGES ACCESSOIRES OU INDIRECTS EST EXCLUE DANS LA MESURE O UNE TELLE EXCLUSION EST PERMISE PAR LA LOI Certains tats provinces ou pays n autorisent aucune restriction sur la dur e d une garantie implicite et certains tats provinces ou pays n autorisent pas l exclusion ou la limitation des dommages cons cutifs ou indirects Par cons quent les restrictions et exclusions d crites ci dessus pourraient ne pas s appliquer dans votre cas La pr sente garantie vous accorde certains droits l gaux sp cifiques et vous pourriez galement en avoir d autres qui peuvent varier d un tat ou d une province l autre et d un pays l autre NOTRE QUPEMENT MOTEUR INETTOYEUR POMPE EAU G N RATRICE GROUPE ELECTROGENE COMMUTATEUR HORS BORD HAUTE Pas disponible aux PORTATIVE inclut le commutateur de transfert lorsque vendu avec DE TRANSFERT PRESSION tats Unis l quipement SOUDEUR moins de 10 kW 10 kW ou plus P RIODE DE GARANTIE Usage par un consommateur 2 ans 1 an 1 an 2 ans 2 ans 3 ans ou 1500 heures Von
55. pment used for Prime Power in place of utility are not applicable to this warranty Electric Powered Pressure Washers used for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS amp STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD ABOUT YOUR WARRANTY We welcome warranty repair and apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty service would not apply if equipment damage occurred because of misuse lack of routine maintenance shipping handling warehousing or improper installation Similarly the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered or modified During the warranty period the Authorized Service Dealer at its option will repair or replace any part that upon examination is found to be defective under normal use and service This warranty will not cover the following repairs and equipment Normal Wear Outdoor Power Equipment like all mechanical devices needs periodic parts and service to perform well This warranty does no
56. r circuit breaker not transfer to generator Generator voltage not acceptable 2 Refer to generator manual Service disconnect breaker open I Reset service disconnect breaker Automatic transfer switch does s js Utility voltage not acceptable 2 Wait for utility voltage to return not transfer to utility to normal Generator is still running after Engine cool down period Engine should stop after minute switch transfers to utility power Supervised loads air conditioner NC contacts not operating correctly Check NC contact for proper etc are not operating when operation and or check control wiring utility is present to external load MO Briggs amp Stratton Power Products Automatic Transfer Switch Briggs amp Stratton Installation and Owner s Manual POWER PRODUCTS TRANSFER SWITCH SCHEMATIC WIRE SCHEMATIC TRANSFER SWITCH OE1 GENERATOR SUPPLY N1 O I o gt I oTi MAIN DISTRIBUTION UTILITY SUPPLY 240VAC PANEL 240 VAC Te Ne Ie TM GENERATOR UTILITY ol Fe e 240 VAC 600VAC 2 AMP FUSE Ne Ee 205 206 J3 Je Ji J4 J6 JS CONTROL BMARD PEJ N C CONTACTS SUPERV ISMRY CONTROL
57. re a new generation of transfer switches that are intended to transfer the entire load of normal residential installations The load is connected either to utility power normal or home standby power emergency The transfer switch monitors utility and generator voltages and will automatically connect to the appropriate source of power Major components of the transfer switch are a 2 pole double throw transfer switch control circuit board fused utility terminals and interconnecting wiring The transfer switch is solenoid operated from utility or generator inputs and contain suitable mechanical and electrical interlock switches to eliminate the possibility of connecting the utility service to the generator output lt has ratings capable of switching full utility power into the residence In addition a manual override lever is provided for the transfer function The control circuit board has active circuits sensing utility and generator voltages lt creates a signal for the generator start up switch transfer retransfer when utility is restored and generator cool down periods The control board also contains red and green LED s indicating the power sources available and two relay operated contacts that provide supervisory control of external loads INSTALLATION Unpacking Delivery Inspection After removing the carton carefully inspect the transfer switch components for any damage that may have occurred during shipment IMPORTAN
58. roducts Description de l quipement Ce commutateur de nouvelle g n ration a t con u pour transf rer la charge compl te d quipements r sidentiels courants La charge est branch e l alimentation de service normal ou la g n ratrice de secours r sidentielle urgence En contr lant la tension de service et celle de la g n ratrice le commutateur de transfert se branche automatiquement la source d lectricit appropri e Les principaux l ments du commutateur de transfert sont un interrupteur bipolaire bidirectionnel un module de commande comprenant une carte de circuit imprim des bornes de d tection de tension avec fusible et le c blage de raccordement Le commutateur de transfert lectromagn tique est actionn par la tension de service et de la g n ratrice et comporte des contacteurs d interdiction m caniques ou lectriques appropri s qui liminent le risque de brancher l alimentation de service la sortie de la g n ratrice Sa capacit nominale est suffisante pour commuter toute la puissance de service de la r sidence Le commutateur comporte un levier de priorit pour transf rer l alimentation manuellement La carte du module de commande comprend des circuits actifs qui contr lent les tensions de service et de la g n ratrice Elle produit les signaux de d marrage de la g n ratrice ainsi que de transfert et de retransfert lorsque l alimentation de service est r tablie et la
59. s d accident caus par un choc lectrique proc dez imm diatement la mise hors tension de l alimentation lectrique et contacter des autorit s locales vitez tout contact direct avec la victime ATTENTION Un traitement inappropri du commutateur de transfert risque de l endommager et de raccourcir sa dur e d utilisation Ne vous servez du commutateur de transfert que pour les utilisations pr vues Si vous avez des questions concernant les utilisations pr vues demandez votre distributeur ou contactez Briggs and Stratton Power Products N exposez PAS le commutateur de transfert une humidit excessive de la poussi re de la salet ou des vapeurs corrosives En d pit de la conception s curitaire du commutateur de transfert le fait d op rer l quipement de fa on imprudente de ne pas l entretenir ou d tre n gligent peut causer des blessures et la mort Demeurez alerte en tout temps lorsque vous travaillez sur cet quipement NE travaillez JAMAIS sur l quipement si vous tes fatigu physiquement ou mentalement Si les appareils branch s surchauffent teignez les et mettez leur disjoncteur ou fusible hors tension Commutateur de transfert automatique Bri Guide d installation et d utilisation Briggs Stratton POWER PRODUCTS INTRODUCTION Nous vous remercions d avoir achet ce commutateur de transfert automatique de Briggs amp Stratton Power Products BSPP Ce commut
60. stolets les boyaux les lances et les buses Est aussi exclu tout quipement us remis neuf ou de d monstration tout quipement utilis pour l alimentation principale en remplacement de l alimentation de service et tout quipement utilis pour l alimentation d appareils de maintien des fonctions vitales BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WI USA Conectador autom tico de Bri Manual de Instalaci n y del Propietario Briggs Stratton POWER PRODUCTS TABLA DE CONTENIDO s amp Stratton Power Products TABLA DE CONTENIDO L 4 k iiai 26 PRUEBA DEL CONECTADOR AUTOM TICO 32 REGLAS DE SEGURIDAD ss ccs cng RR net Rm 27 Secuencia Automatica 32 INTRODUCCION H 28 Fallo de la Red P blica 32 Para el Propietario Comercial o Dom stico 28 Calentamiento del Motor 32 Para el Agente de Ventas Contratista 28 Transferencia bebe EA Ra rues 32 Orientaci n para el Propietario 28 Recuperaci n de la Red P blica 32 Responsabilidades del Instalador 28 Retransferencia 32 Descripci n del Equipo 29 Enfriamiento del Motor 32 INSTALACI N LL 29 Especificaciones cce di 32 Desenmp que 5 254508 dinde Re ENS PODE
61. t cover repair when normal use has exhausted the life of a part or the equipment Installation and Maintenance This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or alteration and modification misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in our judgment to adversely affect its performance and reliability This warranty also does not cover normal maintenance such as adjustments fuel system cleaning and obstruction due to chemical dirt carbon lime etc Other Exclusions This warranty excludes wear items such as quick couplers oil gauges belts o rings filters pump packing etc pumps that have been run without water supplied or damage or malfunctions resulting from accidents abuse modifications alterations or improper servicing or freezing or chemical deterioration Accessory parts such as guns hoses wands and nozzles are excluded from the product warranty Also excluded is used reconditioned and demonstration equipment equipment used for prime power in place of utility power and equipment used in life support applications BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WI USA Commutateur de transfert automatique Bri Guide d installation et d utilisation Briggs Stratton POWER PRODUCTS TABLE DES MATI RES s amp Stratton Power Products TABLE DES MATI RES
62. witch your dealer or your utility power provider The Transfer Switch Warranty is VOID unless the system is installed by a licensed electrical professional For the Installing Dealer Contractor Check federal state and local codes for questions on installation If you need more information about the transfer switch call 1 800 743 4115 between 8 00 AM and 5 00 PM CT Owner Orientation The illustrations are for typical circumstances and are meant to familiarize you with the installation options available with your transfer switch Local codes appearance and distances are the factors that must be considered when negotiating with an installation professional As the distance from the existing electrical service increases compensation in wiring materials must be allowed for This is necessary to comply with local codes and overcome electrical voltage drops The factors mentioned above will have a direct effect on the overall price of your transfer switch installation NOTE Your installer must check local codes AND obtain permits before installing the system Read and follow the instructions given in this manual Follow a regular schedule in caring for and using your transfer switch as specified in the manual Installer Responsibilities Read and observe the safety rules Read and follow the instructions given in this manual e Check federal state and local codes Equipment Description These switches a
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 [PDF形式] Télécharger le numéro D10.1 conc Copyright © All rights reserved.
Failed to retrieve file