1. Instructions Aerada 1100 Series High Arc Faucet 53 304 DC High Arc Infrared Faucet 553 305 AC High Arc Infrared Faucet 232 006 115 volt AC Plug in Adapter 232 005 Multi use AC Adapter maximum 8 faucets 232 007 4 chrome plated Trimplate A WARNING Installations may be performed at different times of construction by different individuals For this reason this manual should be left on site with the facility or maintenance manager Read this entire installation manual to ensure proper installation then file these instructions with the owner or maintenance department Flush all the water supply lines before making connections then make sure the water supply is turned off before beginning installation Do not use pipe dope on faucet and supply connections Possible solenoid contamination could occur and will void any warranty Teflon tape is the recommended sealant The installation site should have access to an electrical box with 120 volt AC 60 Hz cycle for input to a transformer When installing the transformer the electrical box should be located within six feet of the sink The DC faucet is powered by one factory installed 6 volt lithium battery Pressurized plumbing fixtures must be installed in accordance with manufacturer s recommendations The supply piping to these devices must be securely anchored to the building structure to prevent the installed device from unnecessary movement when opera
2. To shut off water flow cover the infrared window with your hand as shown for 5 seconds Remove your hand Water flow will be halted for 90 seconds Cleaning the Inline Filter 1 Shut off the hot and cold water supply Disconnect the hot and cold water lines from the supply lines Remove the filters from the connections and clean them thoroughly of any debris Reinstall filters and connect the hot and cold water lines to the supply pipes Use Teflon tape on the threads to ensure a leak free joint Tighten connections securely Turn water supply on Cleaning the Aerator 1 Shut off the hot and cold water supply Remove the aerator with the spanner wrench and thoroughly clean out any debris Reinstall the aerator using the spanner wrench supplied with the faucet Turn the water supply on Bradley Corporation 215 1558 Rev A EN 07 202 3 8 07 5 Aerada 1100 Series High Arc Faucet Installation Instructions Changing the Battery NOTE When the battery is low the sensor will display a 2 Remove the old battery and replace with a new 6 continuous signal until the battery is completely dead volt lithium battery 1 Remove the fixing screw with wire from the back of the 3 Reinstall the spout fixing screw with wire spout and the setscrew from the side of the spout Remove temperature control knob and setscrew the external temperature control knob
3. 2 Mount the spout and rubber washer to top of base 3 Tighten the spout nut securely to prevent the spout as shown in the illustration Install the second rubber washer steel washer and spout nut underneath the base Securely tighten the spout nut from rotating If necessary support the spout from above to prevent twisting Do not overtighten IMPORTANT Do not use a wrench on spout or inlet tubes 4 AC Only Plug the power supply into the 7 appropriate 110 115V wall outlet Connect the power supply female plug into the faucet male plug NOTE Power supply is equipped with an 11 8 30cm cord For multiple faucet installation an additional extension cord is provided Refer to the wiring diagram packaged with the faucet Connect the hot and cold water lines to the supply pipes Use Teflon tape on the threads to ensure a leak free joint Tighten connections securely Turn the water supply on Remove the protective covering from the sensor Place a hand in front of the sensor for 15 seconds to activate for the first time AC High Arc Faucet shown DC model is similar RUBBER WASHER STEEL WASHER SPOUT NUT HOT AND COLD WATER SUPPLY 3 8 07 Bradley Corporation 215 1558 Rev A EN 07 202 Installation Instructions Aerada 1100 Series High Arc Faucet 2 5 2 Cleaning and Maintenance It is not necessary to shut off water supply to clean the sink
4. ct Supplies Required for Installation e Teflon Tape 1 2 NPT water inlet supply e Pipe fittings 2 3 8 07 Bradley Corporation 215 1558 Rev A EN 07 202 Installation Instructions Aerada 1100 Series High Arc Faucet Components for Aerada 1100 Series Faucet Model 553 305 shown model 553 304 is similar Carefully separate all parts from packaging and check each part with the illustrations below Make sure all parts are accounted for before discarding any packaging material If any parts are missing do not attempt to install your Bradley Faucet until you obtain the missing parts VANDAL RESISTANT AERATOR 505 176 FIXING SCREW WITH WIRE SETSCREW EXTERNAL TEMPERATURE CONTROL KNOB SOLENOID VALVE 269 1806 AC ADAPTER MODULE AC model only ELECTRONIC MODULE 269 1807 BRAIDED SUPPLY HOSE BRAIDED SUPPLY HOSE 5 115V AC PLUG IN ADAPTER 232 006 Bs BACKFLOW SNE FILTER PREVENTER on FILTER 2 ADAPTER FOR ANGLE STOP VALVE O CJ Qo 5 N Bradley Corporation 215 1558 Rev EN 07 202 3 8 07 Aerada 1100 Series High Arc Faucet Installation Instructions 1 nstallation Instructions Turn off water supply to the existing faucet and remove the faucet
5. and the spout Changing the Sensor Detection Range NOTE The detection distance setting can be used to change 2 Hold your hand in the current detection area under the detection distance the water flow until the LED flashes 1 Cover the infrared window as shown below Water will 3 Move your hand to the desired detection range switch off after 5 seconds Keep the window covered and When the LED stays lit for 2 seconds detection the water will come back on after another 5 seconds range is set Uncover the window The detection distance function is now active 6 3 8 07 Bradley Corporation 215 1558 Rev A EN 07 202 Installation Instructions Aerada 1100 Series High Arc Faucet Troubleshooting Problem No water flow Possible Cause Supply valves are closed Possible Solution Open supply valves Faucet is in cleaning mode approx 90 secs Wait for cleaning mode to end Water inlet lines are interrupted or are not in order Inlet water line filter is dirty or blocked Braided supply hose is kinked Backflow preventer BFP is blocked No external water pressure Clean inlet line filter Eliminate braided supply hose kink Eliminate problem at BFP Check water pressure Aerator is blocked or dirty Clean aerator replace if necessary Sensor distance detection is not adj
6. AWG WIRE sos TNE 40 MAX LENGTH 18 AWG WIRE INPUT 100 240 VAC 50 60 Hz 180 mA 18 WIRE NEGATIVE OUTPUT 8 VOC 800 mA 10 MAX LENGTH 16 AWG WIRE FAUCET 1 2 FAUCET 3 HFAUCET 5 7 FAUCET 6 Ph oe 200 FAUCET 8 3 3 8 07 Bradley Corporation 215 1558 Rev EN 07 202
7. e block and solenoid valve Tighten gently to prevent damage Check for rubber washers tighten securely Ensure that solenoid O rings are not damaged Carefully reinstall solenoid and tighten Do not overtighten Faucet drips solenoid valve does not close Clean or replace solenoid valve Temperature cannot be adjusted Not enough hot or cold water Supply valves are closed or not open fully Open supply valves fully Individual inlet lines hot and cold are blocked or kinked Inlet water line filter is dirty or blocked Braided supply hose is kinked Backflow preventer BFP is blocked No external water pressure Clean inlet line filter Eliminate braided supply hose kink Eliminate problem at BFP Check water pressure Temperature of hot water is too low Inspect boiler Braided supply hoses are connected improperly hot water braided supply hose on cold water connection or vice versa Correct the connections Bradley Corporation 215 1558 Rev A EN 07 202 3 8 07 7 Aerada 1100 Series High Arc Faucet Installation Instructions Transformer Connection Detail 232 005 NOTE For bank installation only FAUCET 1 8 CONNECTION DETAIL 40 LENGTH IRE 10 MAX LENGTH 18 AWG WIRE BLACK RED POSITIVE 8 AWG WIRE BLACK NEGATIVES 18 MAX LENGTH 18 AWG WIRE BLACK RED 18
8. ted by the user Use extreme caution when installing the device to prevent damage to the exposed significant surface Compliance and conformity to local codes and ordinances is the responsibility of the installer Product warranties may be found under Product Information on our web site at www bradleycorp com 215 1558 Rev A EN 07 202 P O Box 309 Menomonee Falls WI 53052 0309 2007 Bradley Corporation Phone 1 800 BRADLEY FAX 262 251 5817 Page 1 of 8 3 8 07 http www bradleycorp com Aerada 1100 Series High Arc Faucet Installation Instructions Table of Contents Faucet Dimensions 2 Supplies Required for Installation 2 Faucet Components 3 Installation Information 4 Cleaning and Maintenance 5 Changing the Battery 6 Changing the Sensor Detection 6 Faucet Troubleshooting 7 Transformer Connection Detail 8 Faucet Dimensions 4 8 122 7 6 193mm SW 1 5 38mm 14 356mm SW 0 75 19mm G 3 8 10mm 1 0 9 23mm
9. usted properly Solenoid valve does not open Fixing screw with wire is missing Wire on fixing screw too short or broken off Electronics inoperable Check sensor detection distance adjustment see Changing the Sensor Detection Range page 6 Replace fixing screw with wire Replace fixing screw with wire Contact local Bradley representative Solenoid valve does not open is inoperable Replace solenoid valve No electric power from battery to electronics Battery is drained Battery contacts are corroded Connecting cable is kinked or broken Replace battery Clean contacts Infrared does not detect any object IR window is not transparent scratched or water condensation Interfering reflections from the room Clean window replace if necessary Water runs continuously Solenoid valve does not close or closes late External water pressure is high Solenoid valve is inoperable Check external water supply Replace solenoid valve Sensor detection is not adjusted properly Change sensor detection distance Faucet turns on by itself LED is dirty or has water condensation Clean LED Input line pressure fluctuates Install appropriate line pressure regulators Faucet is leaking water Faucet is not leak tight Connections between housing and braided supply hose Braided supply hose to inlet supply Connection between valv