Home
Bogen 115B Car Speaker User Manual
Contents
1. YELLOW TELCO PAGE FUNCTION TO ANY OTHER TELCO PAGE SUGGESTED TIE FUNCTION STRIP WIRING GREY DRY CONTACTS IN 4004 ce l AT fury fi ae i IN 4004 IN 4004 TGAC PBA3 PBA3 TGAC MCP35A COM BLU amp BRN TRIGGER BLK YEL GRN MCP35A MCP35A LPC4 ALL 2 o GND TELCO IF USED TIME GND TELCO BLK PAGE CLOCK PAGE BLK Figure 2 Wiring Diagram ASF4 Alarm Signaling with PBA3 CPP Handset Communication Option The CPP option uses the Bogen TPS4 panel to provide for control center to classroom and classroom to classroom phone communications The TPS4 includes an ON OFF switch which disconnects the intercom function of the MCP35A to allow private telephone conversations a CALL button which transmits a call tone to selected speakers an IN USE LED which illuminates when handsets are in use and a disconnect function which illuminates an LED and sounds a tone when all handsets are on hook Requires the Model HS201C or HS202C staff classroom phone and Model HS201C phone at the console Refer to Figure 3 Connections Two terminal strips are included to connect the HS201C telephone handset and power supply Connect the HS201C to the terminal strip labeled HS 20 and GND Connect a power supply to the terminals labeled 12V and GND Be sure to observe polarity Operation Receiving a Call From a Staff Station 1 When the call in switch at a sta
2. Options LPC4 Loop Priority Control Option The LPC4 is used to interface the school sound system with satellite systems such as those found in gymnasiums multi purpose rooms etc The option also provides emergency seizure of the satellite system and bridging of their outputs into the main system Refer to figure 1 25V COM CT 25V GABE i AMPLIFIER JIC H 2 A 7 3 E YEL CABLE 25V SPEAKER SYSTEM BOOSTER AMP REMOTE SYSTEM INSIDE MCP35A SBA 225 325 SWITCHBANK OH AUX LINE OUT di 2090 CHASSIS GND 12V 25V BAL INPUT MCP35A Figure 1 Wiring Diagram LPC4 Loop Priority Circuit MCP EXP Input Expander Option The MCP EXP Expander Panel may be used to increase the input capabilities of the sound system Each panel has two banks of four switches and adds up to eight additional inputs to the MCP35A Each bank may be connected to the microphone input MIC1 or MIC2 or AUX input of the MCP35A Banks may be interconnected allowing all eight inputs to feed into one MCP35A MIC or AUX input A multiple expander panel is easily interconnected to fur ther increase the input capacity of the system An input is provided on each bank to replace the MCP35A MIC or AUX input into which the expander is connect ed This input
3. Two staff stations can communicate privately after being connected by the operator at the console place each room selector switch in the C position The console operator may leave the conversation by hanging up the handset As long as the two staff handsets are off hook the green IN USE LED will illuminate When the handsets are returned to the switch hook the DISCONNECT LED will illuminate and the Call In Tone will sound at the MCP35A At this point the operator resets both the room selector panel switches to OFF and presses the ON OFF switch on the TPS4 to release it HS201C WHT wat CRADLE TIP f switcH Shown with phone in cradle RED at BLK L o _e CD HE SBA225 MCP35A HS201C I WHT wut CRADLE re CRN fe SWITCH Shown with phone in crade ED RED ty BLK ole Ii POWER SUPPLY Figure 3 Wiring Diagram CPP Handset Communication Feature SCT Six Circuit Time Signaling Option The SCT option is used with the 6 circuit master clocks and the Bogen TZMA Time Zone Relay module to provide automatic distribution of class change signals Class change signal interrupts programming only at those speakers programmed via the TZMA to receive the signal Requires a dedicated time signaling amplifier a dry con
4. Replace the top cover ACCESSORY CONNECTOR REAR PANEL j PC BD ASSY seel Wl J gt J z J23 8558 i stol ar i E mk lk ji oO x m lt j gt Ml ENE 52 ood J14 MONITOR RED WHT SHIELD Figure 6 Wiring Diagram Installation of Accessory Connector in MCP35A Interconnections Refer to Figure 7 1 Connect the male 6 pin cable connector labeled ACCESSORY on the MCPB to the female 6 pin connector labeled ACCESSORY on the MCP35A 2 Connect the male 9 pin cable connector labeled SWITCHBANK on the top of the MCPB to the 9 pin female connector labeled TO SWITCHBANK on the MCP35A 3 Connect the male 12 pin connector from the SBA325 switchbank to the 12 pin female connector on the MCPB labeled TO SWITCHBANK 4 Connect the MCPB Line Out to the Hi Z Input of the Channel B amplifier 5 Connect the 25V output of the amplifier to the 25V input on the MCPB 10 R 6000 L cD PLAYER ourput SBA325 N TUNER ooo SBA325 d 2 SBA325 MCP35A T725 o AYEL gt 4 ie N rt BLK O74 8 OHM SPEAKER B CHANNEL AMP COM 25V 25V CT HI Z input MCPB AUX LINE OUT OO Figure 7 Wiring Diagram Typical MCPB Interconnection Phantom Power Phantom Power may be enabled for
5. is accessed when all switches in the bank are in the out off position When a switch is placed in the on position the input from each high number switch on the bank is overridden i e the input on switch 3 overrides the input on switch 4 the input on switch 2 overrides the input on switches 3 and 4 and the input on switch 1 overrides the inputs on switches 2 3 and 4 Vertical 0 156 centerlines headers are provided to connect balanced or unbalanced microphones and auxiliary equipment tuners CD players tone generators etc The panel is designed for easy rack mounting and occupies one rack space ASF4 Alarm Signaling Option The ASF4 option provides four distinct tones for use as a manually operated class change or for alarm signaling pur poses slow whoop chime steady and interrupted tone Tones are activated by remote contact closure Note If the MCP35A built in tone signal generator is not used for time signaling it can be used as a single tone alarm and would require only a remote contact closure Refer to Figure 2 PBA3 Push Button Alarm Panel Option The PBA3 Alarm Panel is used with the ASF4 feature to provide activation of three separate alarm signals and includes a reset button Refer to Figure 2 VIOLET ORANGE GREEN BLUE TONE GENERATOR TO LPC4 ALL TERM 4 POWER 4 SUPPLY PBA3 ALARM PANEL BROWN AUDIO INPUT FROM ANY OTHER
6. light annunciated call in with 2 conductor shielded cable Refer to Figure 5 Note Do not use SCR25A with 2 wire call in Refer to MP35A Installation Manual __ To Switchbank Bogen 25 Volt Line Matching Transformer Model T725 1 2W Tap Shown Classroom Wiring Speaker EE TO CALL Console SBA325 Switchbank Wiring Annunciator Line Switchbank wiring for non private operation with two wire annunciator MCPB Figure 5 Wiring Diagram 2 Wire Call In Modification Program Control Panel The Bogen Model MCPB is a program control panel designed to operate with Bogen Series 2233R Centralized School Sound Systems It includes input and pre amplification facilities as well as monitoring control for a separately amplified program channel Channel B The panel interfaces with the Bogen Model MCP35A Master Control Panel which provides the Channel A program facilities and MCPB power supply the SBA325 room selector and annunci ator panels used to place selected speakers on the A or B program busses or select intercom function and a sep arate Channel B program amplifier The MCPB includes inputs for two Lo Z microphones and an auxiliary program source e g CD player receiver Rear panel mounted input gain controls are provided to adjust the input level of each source Phantom power is available for the microphone inputs selectable with a printed circuit board jumper see page 11 Selection of the Channe
7. MIC1 or MIC2 by connecting pins 2 and 3 on the printed circuit board shunts labeled J1 and J2 respectively MIC1 Monitor Mute If the MCP35A console microphone is connected to the MCPB MIC1 input move the shunt labeled J3 on MCPB to the ON position Technical Specifications Rated Output Frequency Response at rated output Distortion Input Sensitivity Signal to Noise Ratio Controls Indicators Input Gain rear panel Program Selection Monitor Program B Program Level Dimensions B Program 1 8V into Hi Z load line out to booster Note The output is unbalanced nominal output impedance is 5 6 kilohms B Program MIC Inputs Shaped for maximum intelligibility 3 dB 300 Hz and 15 kHz AUX Input 1 3 dB from 80 Hz to 15 kHz Less than 1 Rated Power and Bandwidth B Program MIC Inputs 300uV balanced Lo Z for rated output AUX Input 100mV unbalanced Hi Z for rated output B Program MIC Inputs 60 dB below rated output AUX Input 80 dB below rated output MIC1 MIC2 AUX MIC1 MIC2 AUX Two position switch selects program channel for monitoring from MCP35A Adjusts Channel B program level LED Indicators N normal P peak O overload 19 W x 1 3 4 H x 10 D 11 Limited Warranty Exclusion of Certain Damages The Bogen Multi Graphic is warranted to be free from defects in material or workmanship for two 2 years from the date of sale to the original purchaser Any
8. Multi Graphic MCPB amp Series 115B 2223R amp 2233R Installation and User Manual 2009 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 5875 03B 0903 Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of printing However information is subject to change Important Safety Information WARNING To Reduce The Risk of Fire Or Electric Shock Do Not Expose This Apparatus To Rain Or Moisture Always follow these basic safety precautions when installing and using the unit SD oF ew DE Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth DO NOT block any ventilation openings Install in accor dance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked o
9. R amp 2233R The Bogen Multi Graphic Series 2223R provides separate program and intercom channels to permit intercommu nication with any speaker equipped location without interrupting the distribution of program material to the remaining stations The basic system components include the MCP35A control panel SBA225 room selector and annunciator panels and a CD Player Receiver The Series 2233R provides two separate program channels Channel A Channel B and an intercom channel The basic system components include the MCP35A control panel with input and amplification facilities for the Channel A program the MCPB control panel with input and pre amplification facilities for the Channel B program the SBA325 room selector and annunciator panels CD Player Receiver and the Channel B program amplifier The Series 2223R and 2233R are available in a 42 61 1 4 and 77 upright floor rack Maximum system capacity is generally 175 speaker stations consult the Bogen Application Engineering Department if larger capacity is desired Series 2223R and 2233R include provisions for single channel time signal distribution and for call in Also provided is an emergency page function which permits emergency announcements to all speaker equipped stations These emergency announcements override all other system functions and are transmitted at a predetermined level Provisions are included to permit emergency paging from a telephone interphone or microphone
10. RISING OUT OF THE MANUFACTURE SALE OR SUP PLYING OF PRODUCTS EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES Some States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from State to State Products that are out of warranty will also be repaired by the Bogen Factory Service Department same address as above or call 201 934 8500 The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department All shipping charges in addition to parts and labor charges will be at the owner s expense All returns require a Return Authorization number For most efficient warranty or repair service please include a description of the failure Products manufactured and labeled by other companies may be covered by warranties offered by such companies Please call Bogen Customer Service or refer to product packaging for manufacturer s warranty for non Bogen branded products 12 2008 BOGEN COMMUNICATIONS INC 50 Spring Street Ramsey NJ 07446 U S A Tel 201 934 8500 Fax 201 934 9832 www bogen com
11. e vals Sada GENRE ee D KASAENAN EAS S 10 Phantom POWER oo ee SR Re GE EE cantatas Ge Re DE E ee sich De 11 MIG As Monitor Mute EE EE T ANSEES 11 TECHNICAL SPECIFICATIONS ees ese ees ees see esse ese Ge See SR ERGE DR Ge RE ER Ee ER Re Re Re ee ee 11 LIMITED WARRANTY ees seee sees sees see ee ee RE SR ER Ee Re SR EA Ee Ee Re Ee ee Back Cover System Descriptions Series 115B The Bogen Multi Graphic Series 115B Centralized School Sound Systems provides separate program and intercom channels to permit intercommunication with any speaker equipped location without interrupting the distribution of program material to the remaining stations The basic system components include the MCP35A master control panel model SBA225 room selector and annun ciator panels and a CD Player Receiver The system is available in either a single section desktop console with a capacity of up to 75 speaker equipped sta tions or in a dual section desktop console with a capacity of up to 125 speaker equipped stations All Series 115B systems include provisions for single channel time signal distribution and for voice call in Series 115B also provides an emergency page function which permits emergency announcements to all speaker equipped stations These announcements override all other system functions and are transmitted at a predetermined level Provisions are included to permit emergency paging from a telephone interphone or microphone Series 2223
12. ff location is activated the corresponding LED on the room selector panel will illuminate and a tone will sound Answer the call according to the instructions printed on the MCP35A under INTERCOM 2 To speak over handsets instruct the staff location to pick up the handset Then pick up the console handset and press the ON OFF switch on the TPS4 suspends normal intercom communication The green IN USE LED will illuminate 6 3 When a conversation is finished press the ON OFF switch to release it Note that if both parties hang up before the TPS4 is turned off the red DISCONNECT LED will illuminate and the call in tone will sound returning the switch to the OFF position will extinguish both Return the room selector switch to OFF or intercom communica tion will resume Calling a Staff Location 1 Press the ON OFF switch on the TPS4 and pick up the console handset Select the station to be called by placing the appropriate switch on the room selector panel in the C position 2 Call the staff location by pressing the CALL button which sends a call tone to the station loudspeaker Wait for the other party to respond by picking up the handset 3 When the conversation is finished follow step 3 under Receiving a Call From a Staff Station NOTE Alternate Method Call the station using the INTERCOM function of the MCP35A then follow steps 2 and 3 under Receiving a Call From a Staff Station page 6 Calls Between Staff Stations
13. l B program source is by simple push button operation following the color coded guide lines A two position switch MONITOR A B allows selective monitoring of either program channel through the built in monitor speaker on the MCP35A control panel A level control and LED meter are provided to adjust and visually monitor the level A special All Call feature overrides the Channel B bus when the MCP35A is used to make emergency announce ments telephone pages or All Call announcements Interconnection with the MCP35A SBA325 room selector panels and Channel B program amplifier are easily accomplished The panel is finished to match the associated sound system equipment and uses only one rack space Installation Caution Installation of the MCPB requires removal of equipment covers exposing the risk of electrical shock Unauthorized modification can also void the warranty For this reason installation should be performed by quali fied service individuals only Accessory Connector An Accessory connector included with the MCPB must be installed in the MCP35A prior to interconnecting these two units Refer to Figure 6 and the following instructions 1 Remove the top cover of the MCP35A 2 Insert the accessory connector in the rear panel cutout marked ACCESSORY 3 Remove the existing connectors from J10 and J14 4 Push the female connectors on the accessory cable onto the terminal pins of J10 J11 and J14 as shown in Figure 6 5
14. n or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufac turer Unplug this apparatus during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped IMPORTANT CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO PREVENT THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL The lightning flash with arrowhead sym bol within an equilateral triangle is intended to alert the user to the pres ence of uninsulated dangerous volt age within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equi lateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompa nying the appliance Contents SYSTEM DESCRIPTIONS scccsssssscsssssssssessssssscessessssssssesssesseesscesscessseessassscessce
15. part of any Bogen product covered by this warranty that with normal installation and use becomes defective as confirmed by Bogen upon inspection during the applicable warranty period will be repaired or replaced by Bogen at Bogen s option provided the product is shipped insured and prepaid to Bogen Factory Service Department 50 Spring Street Ramsey NJ 07446 USA Repaired or replacement product will be returned to you freight prepaid This warranty does not extend to any of our products that have been subjected to abuse misuse improper storage neglect accident improper installation or have been modified or repaired or altered in any manner whatsoever or where the serial number or date code has been removed or defaced THE FOREGOING LIMITED WARRANTY IS BOGEN S SOLE AND EXCLUSIVE WARRANTY AND THE PUR CHASER S SOLE AND EXCLUSIVE REMEDY BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND EITHER EXPRESS OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposi tion whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS LOSS OF DATA OR LOSS OF USE DAMAGES A
16. seseeses 4 Series VSB EE vests 4 Series 2223R Ge 2Q33R RR ER E AE ER 4 ie ale EE EE RE EE 5 LPC4 Loop Priority Control Option sesse sesse eek ee Ges ee ee ee ee ee ee gee ee ee ee eek Ge ee Re ee eke eek ee 5 MCP EXP Input Expander Option cisciisssicssssss sities gedag ee Genees doek ges ageer AE GER eke geseen Ge kRu ee Eks keed ek 5 ASF4 Alarm Signaling Option sesse see seek gee ee ee ee Ge ee ee ee ee ee ee Gee ee ee ee ee Ge ee ee ee eke Gee 6 PBA3 Push Button Alarm Panel Option ees seen ees eek ee Ge ee ee ee ee ee ee ee ee ee ee ee ee 6 CPP Handset Communication Option iess sesse seen see Geek eek ee ee ee Gee ee ee ee ee ee ee ee ee ee ee ee 6 Gelee ER EO RE OR RE N 6 Operation RE RE ee Oe a 6 Receiving a Call From a Staff Station uses ses seen eek ee eek ee Gee ee ee ee ee ee ee ee ee 6 Calling a Staff Location se De dee eer Dee ee ee eg ee Pe ee ie 7 Calls Between Staff Stations ese vee ee ee ee ee ee ee ee Gee gee ae ee ee ee ee ee Gee i 7 SCT Six Circuit Time Signaling Option sesse seek ee ee ee ee ee ee ee Ge ee ee ee ee ee ek Ge ee ee ees 8 TWK351 4 Two Wire Call in Options iese ees ee ese ee Gee ee ee ee ee ee ee ee ee Gee ee ee ee ee 9 MCPB PROGRAM CONTROL PANEL eee se ees see esse esse ese ee see SR ER Ge SR Ge RE SR ER ER Re Re Re ee 9 INSTALLATION EE N starceros eses sso rse eroas o rosserie dais 10 Accessory CONMECCOR se See De a O E ee ee BE Re RR EE ee EO ee De Ee gee 10 riterconneetionssss es ee Ee e
17. tact clo sure for each circuit plus a common closure Refer to Figure 4 EMERG SW J13 S1A EMERG N C CONTACTS INSIDE MCP35A OGEN TONE GENERATOR MMUNICATIONS Jet TONE LEVEL MASTER CLOCK Requires auxiliary circuits part BCMC 000 100 0 ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6 TN AN EN EN TN e e g fe 2 POWER SUPPLY pt pi pt dd hoe P CONTINUOUS PULSE TONE STEADY TONE N c 38 NO 40 ee n c 41 lee COMMON 42 n o4 43 ee NC 44 ee COMMON 45 nc 47 lee COMMON 48 N 04 49 N c 50 COMMON 51 N 04 52 n c 5300 COMMON 54 Nodss lee oe pt pi 1N4004 x 6 Oo 11 Ts NOTE Use part BCMC 00K 100 0 for rack mounted clocks and part BCMC 00S 100 0 for surface mounted clocks OOOOOO AMPLIFIER COM 25V Figure 4 Wiring Diagram SCT Six Circuit Time Signalling Feature TW Room Speaker NOTE The T buss to G on SBA225 or SBA325 SBA225 or SBA325 K351 and TWK354 Two Wire Call in Options The TWK351 Series 115B 2223R and TWK354 Series 2233R are used only with the CA10A Call in Switches to allow
Download Pdf Manuals
Related Search
Related Contents
User Manual HP ESR20 壁取付用ワイヤレスアンテナ YW Manual Recubrimientos Metal 2014.indd TMO2D Oxygen Analyzer - GE Measurement & Control PDRP-1001/PDRP-1001A/PDRP-1001E Preaction / Deluge System Copyright © All rights reserved.
Failed to retrieve file