Home

AVE RS-485 All in One Printer User Manual

image

Contents

1. AVE Power A B RS 485 Network System Master Operation Manual January 2007 WAVE STRENGTH IN THE BUSINESS E A CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN TO PREVENT ELECTRIC SHOCK DO NOT REMOVE THE COVER DO NOT EXPOSE THE EQUIPMENT TO RAIN OR MOISTURE NO USER SERVICEABLE PARTS ARE INSIDE REFER SERVICING TO QUALIFIED PERSONNEL WARNING THIS EQUIPMENT GENERATES USES AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL MAY CAUSE INTERFERENCE TO RADIO COMMUNICATIONS IT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A COMPUTING DEVICE PURSU ANT TO SUBPART J OF PART 15 OF FCC RULES WHICH ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST SUCH INTERFERENCE WHEN OPERATED IN A COMMERCIAL ENVIROMENT OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE INTERFERENCE IN WHICH CASE THE USER AT HIS HER OWN EXPENSE WILL BE REQUIRED TO TAKE WHATEVER MEASURES MAY BE REQUIRED TO CORRECT THE INTERFERENCE The lightning flash with the arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the produc s enclosure that may be of sufficient magnitude to constitute a risk of electrical shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating
2. removed altered or defaced 5 products returned without an RMA number and sales or delivery receipt showing the date of original purchase 7 use of components that do not meet Seller s specifications 9 external parts such as cabinets or keypads 10 periodic maintenance and adjustments resulting from normal use WARRANTIES EXCLUDED SELLER EXPRESSLY DISCLAIMS AND EX CLUDES ANY EXPRESS OR IMPLIED WARRANTY OR MERCHANTABIL ITY OR FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEEDS OR IS INCONSISTENT WITH THE WARRANTY HEREIN EXPRESSLY SET FORTH NON WARRANTY CLAIMS Inthe event Buyer makes a warranty claim and Seller s warranty does not apply Buyer shall reimburse Seller for all reason able expenses incurred by Seller in diagnosing the installation repair problem T WAVE STRENGTH IN THE BUSINESS ASIA AVE Thailand Ltd 217 4 Crystal Garden Soi 4 Nanatai Sukhumvit Road Klongtoey Klongtoey Bangkok 10110 Thailand Tel 662 656 8231 Fax 662 656 9554 Email ave avethailand com http www ave co th Thai http www avethailand com English NORTH AMERICA AVE Multiview USA 2000 West Governors Circle Suite E Houston Texas 77092 Tel 1 281 443 2300 Fax 1 281 443 8915 Email sales aveusa com http www americanvideoequipment com WESTERN EUROPE AVE Multiview Unit 1C The Potteries Woodgreen Road Waltham Abbey Essex EN9 3SA UK Tel 440 870 770 9323 Fax 440 870 770 9363 Email ave uk
3. XD The Hydra output protocol is commonly called VSI ADD Therefore when connecting to a VSI Pro select this format in the register selection menu When using an AVE DVR select this format when configuring the RS 232 and Text Insertion menus LIMITED WARRANTY Terms and Conditions For 2 years from the date of shipment Seller warrants to Buyer that the Prod uct is free from defects in material or workmanship under normal use and service Equipment manufactured by other than Seller but furnished by Seller carries the same warranty to Buyer as Seller receives from the other manufac turer notwithstanding any provision to the contrary If Buyer has specified a particular manufacturer s product which is not the brand standardly supplied by Seller Buyer shall look only to the other manufacturer s warranty and Seller shall not warrant such item EXCLUSIONS Sellers warranty does not cover the following 1 in transit damage claims improper handling by carrier or post office Note only the consignee of the shipment can file a claim with the common carrier 2 damages caused by incorrect use modification carelessness improper storage hostile operating conditions or unauthorized service installation or repairs without proper training from the Seller 3 damages caused by fire flood lightning collision acts of God or other events beyond the control of Seller 4 products or parts thereof that have had serial numbers
4. and maintenance servicing instructions in the literature accompanying the appliance Copyright C AVE Thailand Co Ltd 2000 2007 2 5 2 PECCAN 3 EEE 4 OIC OID 2 5 Address Eao Riada rea iria 6 LED Status UGC AUG Asses tice de 6 __ SPECIFICATIONS Electrical Characteristics Operating VOMAGC cisscssssticcmcenaseinvenasetodsnaseciedenendiesanicocnaasedsensusenccie 9 12VDC lt 200 12VDC Data 1 x RS 232 DB 9 2 RS 485 RJ45 Physical Characteristics SZC esas E E E A EE 130 x 125 x 32 mm 5 1 x 4 9 x 1 3 in AE E EE E E TE T A AE T E T E E TA 600 g 1 3 Ibs eee een eee E EE Beige Metal RS 232 Parameters Baud AE nak eee cues 9600 Dala B enea E 8 AE AEE EAE None OD 1 Network Parameters 40 o ee ee RS 485 Max Line 5 4000 ft Typ 120 Ohm Terminated INTRODUCTION The Hydra is an interface device that allows the connection of multiple cash register terminals using the Regcom Networker Vnetworker slave units for the purpose of transaction logging The Hydra receives RS 485 data from the Regcom Networker Vnetworker networks and converts this to an RS 232 format that DVRs or the VSI Pro can rea
5. d Master Device Hydra RS 485 Network Regcom Regcom Regcom Cash Register Cash Register Cash Register Figure 1 Network Diagram CONNECTIONS The Hydra uses a bi directional 2 wire RS 485 data bus to communicate to the slave devices device at each end of the network must be terminated An 8 DIP switch on the rear of the unit is used to set the termination Switch No 8 is the terminal switch When set to ON the device is terminated When set to OFF it will be un terminated E a 12V06 ae SWI Figure 2 Regcom Rear Panel OO y OPNI _ 2 PIN4A o OPNS PIN5 PIN 4 PING PING PINS O PIN7Z Y Y OPNS si PINS _ Table 1 DB 9 Pin Out Table 2 RJ45 Pin Out 120 Ohm impedance terminated RJ45 RJ45 PIN4 PIN4 PIN 5 PIN 5 Table 3 RS 485 Network Data Cable Wiring 5 LED STATUS INDICATION The front panel of the unit has 3 LED indicators one to show when power 15 connected and two to indicate the status of the device as follows When the unit is powered up it performs a self test status light B will illuminate to indicate the test has completed successfully and that the unit is functioning correctly Status light A will flash whenever data is received at the RS485 input Cable Connections Hydra PC DVR VSI Pro DB9M DB9F DB9M GND 5 5 GND 5 GND VAD e 2 2R
6. multiview net www multiview net

Download Pdf Manuals

image

Related Search

Related Contents

lève-personnes - Laboratoire national de métrologie et d`essais  secretaire m edical(e)  OPERATING INSTRUCTIONS  JBL ESC333 Stereo System User Manual  

Copyright © All rights reserved.
Failed to retrieve file