Home
Aprilaire 8600 Thermostat User Manual
Contents
1. Model 8600 Universal rilaire Touch Screen Thermostat nes Owner s Manual IGE 8 m Includes irene Rif FILTER Operating Instructions and 9 45 Warranty Information 6 1 10 READ AND SAVE THESE INSTRUCTIONS 61000728A 8600 Tstat Owners indd 1 10 7 10 11 44 50 AM TABLE OF CONTENTS ABOUT YOUR NEW THERMOSTAT Thermostat features 3 Controls amp display overview 4 5 OPERATION Select system mode HEAT COOL 6 Change temperature set point 6 Select fan setting ON AUTO CIRC i Clean CIECZY 7 Maintenance lt 7 Screen 0 7 Battery installation 563 4394 8 61000728A 8600 Tstat Owners indd 2 PROGRAMMING set time and date 9 Understanding program schedules 10 11 Progressive 11 Changing program schedules 12 13 Program schedule holds REPRE dear rin ds 14 Permanent E Rm drei 15 NAGANO T TD 15 16 SETUP MENU How to enter the setup menu to change 17 User system settings table 18 WARRANTY Limited 19 Warranty registration 19 10 7 10 11
2. OPERATION SELECT FAN SETTING ON AUTO CIRC When the fan mode is changed during a program event It remains in that mode until the next event starts The fan must be programmed to FAN ON in the schedule to run continuously through all events MON Inside Set To 55 cer DOO Press FAN to select ON Fan runs continuously Use this mode for maximum air circulation filtering AUTO Fan runs only when the heating or cooling system Is On CIRC Same as AUTO but ensures the fan is on for at least 20 minutes per hour Use this mode for a balance of energy savings and air circulation cleaning Press DONE to save and exit Or CANCEL to exit without saving The thermostat will save and exit if nothing is pressed within 10 seconds 61000728A 8600 Tstat Owners indd 7 CLEAN SCREEN Press MENU to enter the main menu Press CLEAN SCREEN to disable the touch screen for 30 seconds for cleaning Note Use a soft damp cloth to clean the screen Use water or household glass cleaner Do not spray liquids directly on the screen MAINTENANCE REMINDERS Maintenance reminders are set up by the installer to indicate when the equipment is due for service If a maintenance reminder is displayed call your HVAC dealer for service They can be cleared by pressing MENU to enter the main menu then Next to clear each reminder SCREEN LOCKOUT The user can disable certain features of the thermostat See User System
3. Press COPY to copy the schedule of the day just Press Next to advance to the next event programmed to any other day Repeat above process for each remaining event OR Press DONE to save the schedule for the day Press CANCEL to proceed to the next day and repeat the above process 61000728A 8600 Tstat Owners indd 13 10 7 10 11 44 58 AM PROGRAMMING PROGRAM SCHEDULE HOLDS TEMPORARY TEMPORARY PROGRAM HOLD Press 4 or W to adjust the end time of the hold If Press or W to immediately adjust the temperature end time is not adjusted the Temporary Hold will end at when the schedule is running This will temporarily hold the start of the next event the temperature setting until the next scheduled event Temp Hold Hold Until CANCEL j HOLD LILI PM 8 1118 DONE Temp Hold To cancel the Temporary Hold press CANCEL HOLD 61000728A 8600 Tstat Owners indd 14 10 7 10 11 44 58 AM PROGRAMMING PROGRAM SCHEDULE HOLDS PERMANENT PROGRAM SCHEDULE HOLDS VACATION PERMANENT PROGRAM HOLD VACATION PROGRAM HOLD Press HOLD to permanently hold the temperature at This energy saving feature allows you to suspend the Its current setting while the schedule is running This programmed schedule for extended periods of time The will override the temperature settings for all events temperature you select will be maintained 24 hours a With the thermostat in Permanent Hold the temperature da
4. Press DONE to save and exit Or CANCEL to exit without saving The thermostat will discard changes and exit if nothing SETUP DONE lt thes is pressed within 60 seconds Press Next or Back to page through the settings the setting is displayed in the message center MESSAGE CENTER SCROLLING TEXT LEMRERATURE SCAL FAHRENHEIT 61000728A 8600 Tstat Owners indd 17 10 7 10 11 45 00 AM SETUP MENU USER SYSTEM SETTINGS TABLE The following table is the list of the settings and their details Default settings are shown in bold User system setting Description Factory default setting bold and setting range Temperature Set the thermostat to Fahrenheit scale Fahrenheit or Celsius mode Celsius Screen lockout Screen lockout level OFF No lockout Partial lockout Full lockout Partial lockout type only available when Screen Allow changes to Fan Mode System Mode and Setpoints lockout is set to partial lockout Allow changes to Fan Mode and Setpoints only Allow changes to Setpoints only Setpoint lockout only available when Screen 3 F or C from current setpoint limit lockout is set to partial lockout 1 to 20 OFF indicates no setpoint changes Events per day Number of program events 4 events per day per day 2 events per day Backlight intensity Backlight intensity as a 100 percentage of full on Selection of 0 100 Daylight savings Enable or disable auto OFF daylight savings
5. 17 C 82 F 28 C AUTO PROGRESSIVE RECOVERY The Progressive Recovery feature allows the thermostat to activate the heating and cooling equipment prior to an event in order to reach the desired temperature at the start of the next scheduled event Example If the WAKE time is 6 am and the temperature is 70 the heat will come on before 6 am so the temperature is 70 by the time you wake at 6 am 61000728A 8600 Tstat Owners indd 11 10 7 10 11 44 56 AM PROGRAMMING CHANGING PROGRAM SCHEDULES Press MENU to enter the main menu Press Next then A or W to set the start time of Press SET SCHEDULE to enter schedule programming the first event scHiduLe WAKE EVENT WAKE 15 897 TIME LEAVE RET gt bili Pa Press 4 or W to select the day CO OJ Press Next then MA or W to set the setpoints of the first event LIC COE INI USE hj JUIN TM LECT 1 HEAT ANS e PDT WTS Cool Next OAM gt JU Note This step is not displayed for weekday weekend schedules 12 61000728A 8600 Tstat Owners indd 12 10 7 10 11 44 57 AM PROGRAMMING CHANGING PROGRAM SCHEDULES CONTINUED Press Next then FAN to set the fan mode of the The thermostat will display the COPY option first event N 7 MONJ TUE WED THU FR SAT ON AUTO CIRC Dv MIN ITIC V CU i PL TILIHN ULT TI IF YES COPY ia sexuel PRESS FAN TO l WAK SELECT FAN MOTE ext
6. Setting Table on page 18 for details This feature can be overridden by pressing and holding MENU for 7 seconds 10 7 10 11 44 55 AM OPERATION BATTERY INSTALLATION The thermostat can either be AC or battery powered or both If the thermostat was wired to be AC powered when installed batteries are optional to provide BUTTON backup power for clock RR Z L The thermostat has a memory backup that saves the thermostat s settings in case of a power interruption The system settings will be retained but the clock will reset after 90 seconds with no battery or AC power The reset button located under the battery cover can be used to reset the thermostat to factory defaults WARNING The reset button should only be used by the installer 61000728A 8600 Tstat Owners indd 8 10 7 10 11 44 55 AM PROGRAMMING SET TIME SET DATE Press MENU to enter the main menu Press MENU to enter the main menu Press SET CLOCK to enter clock menu Press SET DATE to enter date menu Press amp or W to set the hour SET HOURS Bieg V gt 1 261 10 Press Next then 4 or W to set the minute Press Next then 4 or W to set the day Press DONE to save and exit Or CANCEL to exit Press Next then or W to set the year without saving The thermostat will save and exit if Press DONE to save and exit Or CANCEL to exit nothing is pressed within 20 seconds without saving The thermostat will sa
7. Tstat Owners indd 20 10 7 10 11 45 01 AM
8. 44 50 ABOUT YOUR NEW THERMOSTAT WARNING Do not use sharp instruments to press touch screen Only use your fingertips THERMOSTAT FEATURES e Large touch screen with adjustable backlight constant backlight available e Message center provides feedback and instructions e day programmability or separately programmable weekday weekend schedules e Thermostat can be removed from the wall for easy programming batteries must be installed e Front battery door access for fast easy replacement e Displays room temperature temperature setting and optional outdoor temperature e Air filter humidifier dehumidifier and HVAC service indicators e Programmable fan control with fan circulation mode e Fasy to use temperature control can override program schedule at any time e Progressive recovery ensures proper temperature at the start of a program event e Built in compressor protection prevents damage to your equipment 61000728A 8600 Tstat Owners indd 3 10 7 10 11 44 50 AM ABOUT YOUR NEW THERMOSTAT CONTROLS amp DISPLAY OVERVIEW HOME SCREEN ROOM TEMPERATURE CURRENT DAY OUTDOOR TEMPERATURE TEMPERATURE SETTING FAN MODE BUTTON id rilaire TEMPERATURE FAN MODE ADJUSTMENT SETTING SYSTEM MODE BUTTON HOLD BUTTON SETS OR CLEARS HOLD SYSTEM MODE SETTING IN INIT RUN HEAT PUMP MODE ONLY EQUIPMENT EM M EMERGENCY HEAT RED STATUS gt 1 SYSTEM FAULT YELLOW INDICATOR SHO
9. FROM FAILURE TO HAVE THIS THERMOSTAT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This equipment if installed in strict accordance with the manufacturer s instructions complies with the limits for a Class B computing device pursuant to Subpart J of Part 15 of FCC Rules WARRANTY REGISTRATION Please lake a few minutes to visit us on line at www aprilaire com to register your Aprilaire product If you do not have on line access please mail a postcard with your name address phone number product purchased and date of purchase to Research Products Corporation BOX 1467 Madison WI 53701 Your Warranty Registration information will not be sold or shared outside of this company 19 61000728A 8600 Tstat Owners indd 19 10 7 10 11 45 01 AM P O 1467 e Madison WI 53701 1467 e Phone 800 334 6011 e Fax 608 257 4357 www aprilaire com 61000728 10 10 B2205242A 2010 Aprilaire A division of Research Products Corporation 61000728A 8600
10. Second Sunday in March to the first Sunday in November First Sunday in April to the last Sunday in October 61000728A 8600 Tstat Owners indd 18 10 7 10 11 45 00 AM THERMOSTAT FIVE YEAR LIMITED WARRANTY Your Research Products Corporation Aprilaire Thermostat unit is expressly warranted for five 5 years from date of installation to be free from defects in materials or workmanship Research Products Corporation s exclusive obligation under this warranty shall be to supply without charge a replacement for any thermostat which is found to be defective within such five 5 year period and which is returned together with the date of installation no later than thirty 30 days after said five 5 year period by you to either your original supplier or to Research Products Corporation Madison Wisconsin 53701 THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE THERMOSTAT ITSELF IMPLIED WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECT S RESULT
11. WS THROUGH HOUSING MESSAGE CENTER SCROLLING TEXT LOW BATTERY INDICATOR CURRENT TIME amp DATE MAIN MENU BUTTON NOTE BACKLIGHT IS ACTIVATED WITH FIRST BUTTON PRESS AND AUTOMATICALLY TURNS OFF 61000728A 8600 Tstat Owners indd 4 10 7 10 11 44 52 AM ABOUT YOUR NEW THERMOSTAT CONTROLS amp DISPLAY OVERVIEW MAIN MENU CLEAN SCREEN rilaire LOCKOUT TOUCH SCREEN FOR 30 SECONDS SET VACATION HOLD HOLD TO TIME AND DATE SET CURRENT TIME SET SCHEDULE BUTTON SET CURRENT DATE DONE BUTTON EXIT MENU USER SYSTEM SETTINGS 61000728A 8600 Tstat Owners indd 5 10 7 10 11 44 53 AM OPERATION SELECT SYSTEM MODE EM HEAT HEAT OFF COOL AUTO Press MODE to select EM HEAT only for heat pumps with auxiliary heat Thermostat controls auxiliary heat Heat pump will not operate in EM HEAT mode HEAT Thermostat controls only the heating system OFF Heating and cooling systems are off COOL Thermostat controls only the cooling system AUTO if enabled in installer setup Thermostat automatically selects heating or cooling depending on the indoor temperature Press DONE to save and exit Or CANCEL to exit without saving The thermostat will save and exit if nothing is pressed within 10 seconds 61000728A 8600 Tstat Owners indd 6 CHANGE TEMPERATURE SET POINT Press 4 or W to adjust the current set point See Program Schedule Holds on pages 14 16 for more information 10 7 10 11 44 54 AM
12. ve and exit if nothing is pressed within 20 seconds 61000728A 8600 Tstat Owners indd 9 10 7 10 11 44 56 AM PROGRAMMING UNDERSTANDING PROGRAM SCHEDULES The daily schedule is split into four sections WAKE temperature you would prefer to wake up to LEAVE temperature when you are away from the house RETURN temperature you would prefer to return home to SLEEP temperature you would prefer while sleeping The times shown in the table below are the defaults The start time and temperature of each section can be changed to fit your schedule See Changing Program Schedules section on pages 12 13 This thermostat is pre set to use the following program settings see table below We recommend these settings since they can reduce your heating cooling expenses The fan program is pre set to AUTO for all events Set temperature Event designator Start time Heat Cool Fan WAKE 6 00AM 70 F 21 C 78 F 26 C AUTO LEAVE 8 00AM 62 F 17 C 85 F 29 C AUTO RETURN 5 00PM ZO FAZT C 78 F 26 C AUTO SLEEP 10 00PM 62 F 17 C 82 F 28 C AUTO 61000728A 8600 Tstat Owners indd 10 10 7 10 11 44 56 AM PROGRAMMING UNDERSTANDING PROGRAM SCHEDULES CONTINUED Optionally the thermostat can be set to a two event or commercial schedule See Setup Menu on page 17 Set temperature Event designator Start time Heat Cool Fan WAKE OCCUPIED 6 00AM 70 F 21 C 78 F 26 C AUTO LEAVE UNOCCUPIED 10 00PM 62 F
13. y until the vacation program hold end date and time setting and fan mode can be adjusted and will stay at Once the end date and time have been surpassed the that setting until the hold is cancelled previously programmed schedule will resume If you return earlier than expected press CANCEL HOLD to resume the programmed schedule Press MENU to enter the main menu Press SET VACATION to enter vacation program hold Perm Hold Press A Y To cancel the Permanent Hold press CANCEL HOLD to adjust the temperature setting 61000728A 8600 Tstat Owners indd 15 10 7 10 11 44 59 AM PROGRAMMING PROGRAM SCHEDULE HOLDS VACATION CONTINUED VACATION PROGRAM HOLD continued Press Next then 4 or W to set end date Press Next then FAN to set the fan mode EET UBFEPTERI S I V FIL I LLIIN NT Th TE U NTI Back Next 6 90 YEG ID Press Next then or W to set end time T TT GET VACATION AIN TTM NJ 1211 Back GET VACATION FAN MOD Back Next LILJ PM W 7250 Press DONE to save and exit Or CANCEL to exit without saving The thermostat will save and exit if nothing is pressed within 20 seconds 61000728A 8600 Tstat Owners indd 16 10 7 10 11 45 00 AM SETUP MENU HOW TO ENTER THE SETUP MENU TO CHANGE SETTINGS Press MENU to enter the main menu Press 4 or W to adjust the setting Selected option Press SETUP to enter the setup menu flashes
Download Pdf Manuals
Related Search
Related Contents
波高分析ソフトウェア KF-50A 3 4 5 6 7 8 Installation and Operation User Guide Epson EHDMC 10 Operating Instructions オーダーシステム カタログ No.1 - パナソニックオーダーシステム専門店 Notice d`instruction GX Works2 Beginner`s Manual (Structured Project) Copyright © All rights reserved.
Failed to retrieve file