Home

AMX 544/580 Network Card User Manual

image

Contents

1. 580 CSG Specifications continued Included PSN3 0 Power Supply 3 0A 12 0CVD FG423 31 Accessories CSG SIP Communications Gateway Installation Guide 93 2182 01 2 Surface mounting brackets 62 2182 04 4 4 40 X 250 PPH screws 80 0112 DIN Rail Mounting Bracket FG532 06 Other AMX Equipment Installing the Hardware CAUTION To reduce the risk of fire use only No 26 AWG or larger telecommunication wiring for network connections 1 Connect an Ethernet cable to the Network port 2 Connect the provided power supply to the unit s DC connector The unit immediately receives power once you connect a power source to it 3 When the unit completes the boot process the left most eight LEDs indicate how the analog ports are configured A red light indicates the port is FXO and a green light indicates the port is FXS If the light for a port is off the port is not installed Note The analog port configuration is selected when you purchase your CSG unit 4 Connect telephones to the analog ports that are configured as FXS ports and connect phone lines to the analog ports that are configured as FXO ports If you are using the CSG 500 you can skip this step WARNING If you are using the CSG 544 do NOT connect analog ports 1 4 to a phone line Since both the FXS port and the phone line supply power the hardware could sustain damage This damage is not covered under the AMX standard warran
2. an EA ATTENTION READ THIS FIRST For more detailed installation configuration programming and operating instructions refer to the CSG SIP Communications Gateway Instruction Manual available on line at www amx com Network FIG 1 CSG SIP Communications Gateway displaying CSG 544 Overview The CSG SIP Communications Gateway FIG 1 is a stand alone Private Branch Exchange PBX which runs a version of Asterisk The CSG can function not only as a PBX but also as VoIP ATA or VoIP gateway It has eight analog ports that can be configured via modules as Foreign Exchange Office FXO or Foreign Exchange Station FXS ports The CSG enables you to transform an intercom enabled Modero Touch Panel into a full featured IP phone With the CSG and an intercom enabled Modero Touch Panel you can make and receive local long distance and international phone calls and have access to phone features like call waiting caller ID call forwarding call queuing and voice mail The CSG supports AMX Session Initiated Protocol SIP enabled touch panels such as the MVP 8400i NXD 1000Vi and NXD 700Vi as well as 3rd party IP phones Specifications CSG Specifications Dimensions 1 74 x 11 45 x 5 44 4 41 cm x 29 09 cm x 13 82 cm Weight 2 25 Ibs 1 02 kg Enclosure Metal with black matte finish Power Constant current draw 2 6 A 12 VDC Requirements Memory 8MB on board serial Flash memory 64MB 16
3. ate network 4 Ensure the DHCP check box is checked Note If you have difficulty obtaining an IP address dynamically clear the DHCP check box and specify the IP address subnet gateway and DNS settings This information should be available from your network administrator or Internet Service Provider ISP 5 Click the IP Phones tab You can use the options on this tab to establish settings to access your CSG 6 Enter the IP address subnet or any other appropriate information necessary to access your CSG 7 Click the Timezones tab Select a time zone from the provided drop down combo box 9 Click Accept For full warranty information refer to the AMX Instruction Manual s associated with your Product s 7 08 2008 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com Setting Up Your Touch Panel to Work with Your CSG Follow these steps to configure your touch panel to work with the CSG 1 From the main Setup page on your touch panel press Protected Setup The Protected Setup page opens 2 Press Other Settings A slide out menu appears 3 Press SIP The SIP Settings page opens FIG 2 SIP Settings Status Gomection State ame Enable Cancel FIG 2 SIP Settings pa
4. bit parallel SDRAM Certifications FCC Class A CE IEC60950 and ROHS Operating Operating Temperature 0 C 32 F to 40 C 104 F Storage Operating Humidity 5 to 85 RH Non Condensing Environment storage Temperature 20 C 4 F to 70 C 158 F Storage Humidity 0 to 85 RH Non Condensing Front Panel Components Power LED Indicates whether the unit is turned on and receiving power Network LED Indicates whether a network cable is connected and the speed of the network IP Phones Indicates whether the corresponding link is connected and the LEDs speed of the link Analog LEDs Indicates whether the analog port is installed and the type of port FXO FXS installed Not available on all models Rear Panel Components Power 5 1mm OD 2 1mm pin 12V 3 0A center positive connector Configuration Resets the current configuration to the factory default when Reset Switch pressed continuously during the boot process Console port 1 RJ45 port for console craft port serial control Network port 1 RJ45 10 100baseT port for a general WAN connection IP Phones 4 RJ45 10 100baseT ports for IP phone connections ports Analog ports 8 RJ11 ports 4 for FXO and 4 for FXS connections CSG 544 only 8 RJ11 ports for FXO connections CSG 580 only Note The CSG 500 does not use analog ports Installation Guide CSG SIP Communications Gateway CSG 500 544
5. ff No line is connected or the interface is inactive Phones Say 4 ports Green Link is up at 100Mbps LED flashes at 1 10 second flashing intervals as traffic is detected Red flashing Link is up at 10Mbps LED flashes at 1 10 second intervals as traffic is detected LED Definitions continued Analog Off No analog port is installed in the corresponding port 8 ports Green solid Port is configured for FXS operation and is enabled An analog telephone may be connected to this port Green Telephone is ringing flashing Green slow Telephone is in use blinking Red solid Port is configured for FXO operation and is enabled A telephone line may be connected to this port Red flashing Telephone line is ringing Red slow blinking Telephone line is in use Setting Up Your System The CSG comes with a user interface framework which gives you the ability to configure it through an easy to use interface To access the interface you will need the IP address your CSG server is using Once you have the IP address you can configure your CSG via a web browser The user interface included as part of the CSG implementation provided with the CSG gives you the ability to set up a telephone system without the need to use command line configuration The user interface opens on the main menu which gives you the ability to add features or further modify an exis
6. ge 4 Inthe Proxy Address field enter the IP address or DNS name of the server you want to access The IP address depends on whether you connect the touch panel to one of the IP Phone ports or through the LAN with the CSG 5 In the Port Number field enter the port number of the server you want to access The default port number is 5060 6 In the User Name field enter a user name you can use for authentication to the server Normally the user name is the same as the phone number assigned to the extension you are using FA In the Password field enter the password for the user name 8 Press Enable to have your panel read the configuration and attempt to connect to the proxy server 9 Press Save 10 Press Back to return to the previous page Compatible Devices The following list describes all SIP enabled touch panels that are compatible with the CSG MVP 8400i NXD 700Vi NXD 1000Vi The firmware for these panels must be up to date to use SIP 93 2182 01 Bs REV D A L baag Fa
7. ting configurations The following sections provide information about procedures you may want to perform when you are getting started Logging on to the Server for the First Time Connect a computer to the LAN IP Phone port on the CSG with an Ethernet cable In the address field of a web browser enter the default IP address of http 192 168 69 1 To log on to the system enter the following user name and password Username admin Password 1988 Subsequent Logons to the CSG The method described above will work to log onto the configuration tool of the CSG In addition you can log onto the CSG using the CSG s Network port once it has been enabled In this case open a web browser on a computer which is located on the same network as the CSG In the address field of the web browser enter the IP address of the CSG as defined during the initial installation Changing Your Network Configuration DHCP is automatically enabled for Wide Area Networks WAN by default If you need to change your network configuration like set a static IP address for example the Networking Configuration page enables you to make any necessary changes Follow these steps to change your network configuration 1 Select Network Main from the System tab 2 Enter the host name for your server 3 Click the WAN Network tab You can use the options on this tab to establish the settings that enable you to connect to the Internet or to an internal priv
8. ty Instructions for Wall Mounting 1 Select the area to mount the CSG unit The unit should be mounted at or below eye level to properly view the LEDs 2 Line up one of the surface mounting brackets with the two holes on one side of the CSG Install two 4 40 X 250 PPH screws into the holes in the bracket to secure the bracket to the CSG 3 Repeat step 2 to attach the second bracket to the other side of the unit 4 Affix one screw to the wall Leave approximately 1 4 inch of the screw protruding from the wall to allow the head of the screw to slide into the settings on the mounting bracket mounting the unit to the wall 5 Repeat step 4 to attach the second bracket to the wall Understanding the LEDs There are 14 LEDs on the front panel of the CSG The eight LEDs corresponding to the analog ports on the rear panel indicate the type of interface installed The following table explains the definition of each LED and its color representation LED Definitions LED Color Description Power Blue pulsing On when the unit boots up after the bootload process has completed The LED pulses at a rate which is proportional to the BlackFin processor load Network Off No line is connected or the interface is inactive Green Link is up at 100Mbps LED flashes at 1 10 second flashing intervals as traffic is detected Red flashing Link is up at 10Mbps LED flashes at 1 10 second intervals as traffic is detected IP O

Download Pdf Manuals

image

Related Search

Related Contents

varias veces  MemCom Monitor User Manual  Manuel de Reparation de L`Emetteur Recepteur  取扱説明書 - SOOKI  Graco Inc. 1535 Pressure Washer User Manual    PRO OMIX2 0U  轟ぎ茎タルホームターミナルリモコンの ボタンを押してください。  FireWire Card  

Copyright © All rights reserved.
Failed to retrieve file