Home
Amcor 12000E Air Conditioner User Manual
Contents
1. AMCOR ENGLISH INSTRUCTION MANUAL S20 q 9000E 12000E 15000E PLUS HEATER VERSIONS Thank you for choosing this innovative Amcor air conditioner We suggest that you keep this manual in a safe place for future reference It describes the many benefits and advanced features this unique product has to offer Before you use your new air conditioner you should carefully read these instructions to maximise this product s performance For over 50 years Amcor has specialised in complete indoor environmental control manufacturing and marketing dehumidifiers portable air conditioners coolers air purifiers ionisers and aroma therapy scent diffusers These world class products incorporate the latest technological developments ELECTRIC CONNECTION For your safety please read the following information Warning This appliance must be earthed The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse Should the fuse require replacement it must be replaced with a fuse rated at 13 amp and approved to BS1362 The plug contains a removable fuse cover that must be refitted when the fuse is replaced In the event of the fuse cover being lost or damaged the plug must not be used until a replacement cover has been obtained If the moulded mains plug is unsuitable for the socket outlet in your home or is removed for any other reason then the fuse should be removed a
2. Remove the blockage Room temperature lower than the selected value Change temperature selection The unit is noisy Unit stands uneven Place on an even solid surface less vibrations The compressor does not work The overheat protection is probably activated Wait 3 minutes until the temperature has decreased then turn on the unit again The remote control does not function Distance too great Remote control signal not detected by the control panel The batteries are drained Make sure the remote control is correctly aimed at the control panel Replace the batteries To correct problems that have not been described in the table and or if the recommended solutions fail to solve the problem contact an authorized service centre STORAGE Empty the internal water container Clean the screen filter Remove 3M Filtrete filter and active carbon filter Remove the Filtrete filter and active carbon filter before end of season storage and install new filters at the beginning of the new season The old filters can be disposed of in the Non biological rubbish container Replacement filter packages are available from Amcor Put the unit in Fan Only mode for a few hours to ensure that the inside becomes completely dry Store the cable as shown Protect the unit against dust and store in a dry place not accessible to children TE
3. temperature of 22 C The fan speed will be selected automatically Heat mode is only available on EH models Fan speed If you prefer a constant fan speed instead of the auto fan speed press the button successively the fan icon on LCD display will rotate accordingly Fast for the turbo speed e Normal for the medium speed Slow for the slow speed Alternating for the auto fan speed in the cooling mode only Heat EH models feature a 1650 W electric heater that can heat a room on cooler days With the mode switch select set the desired temperature and the unit will heat until this temperature is reached Fan speed is selected automatically Do not place the unit near anything that could catch fire or be scorched Do not obstruct the air outlet The heat function will operate with or without the hose attached Timer For all of the following TIMER programming proceed firstly with these standard steps Press the button briefly the 2 left digits of the 4 digits the LCD display are flashing e Press or to adjust the hour Press the button briefly again the 2 right digits of the 4 digits are flashing e Press O or 7 to adjust the minutes of the clock in intervals of 5 minutes The timer is set After 10 seconds the time display returns Programming the timer for ON when the unit is OFF Perform the standard steps as described above The circular time scale will be on
4. CHNICAL DATA Model 9000E 12000E 15000E 9000EH 12000EH 15000EH Cooling apacity BTU h 7000 9000 12000 kW 2 2 6 3 5 Power consumption Cooling 880 1100 1330 Heating EH only Ww 1700 heating element EH only 1600 Current Cooling 4 5 6 Heating EH only A 7 5 Mains V Hz PH 220 240 50 1 Compressor model rotary Fan speeds 3 2 1 turbo Thermostatic range 18 32 Refrigerant charge type g R407C 480 R407C 570 R407C 650 Dimensions w x h mm 555 x 800 x 455 Net weight kg 31 5 34 39 measured conform EN 14511 Subject to modifications without prior notice For greater precision please refer to the rating label placed on the product Reminder Waste electrical products must not be disposed of with household waste This product should be taken to your local recycling centre for safe treatment YOUR GUARANTEE DOMESTIC AIR CONDITIONERS If this product is found to be defective as a result of faulty materials or workmanship within one year from date of purchase it will be repaired or replaced free of charge This guarantee is subject to the following terms Amcor Limited must be notified of the fault Proof of purchase must be presented to 5 nominated representative The warranty will be void if the product is modified misused or repaired by an unauthorised person The guarantee does not cover accidental damage misuse or consumabl
5. arm air return in the room Continuous drainage is then necessary and more efficient For continuous drainage e Switch off the unit and remove the plug from the mains Remove the water stopper and rubber plug Connect a drain tube 20 mm inner dimension onto the water outlet and extend with extra water tube if needed Place the other end in a normal drain Make sure that the tube is free from twists and bends The tube must decline over its entire length AIR FILTER This air conditioner can be equipped with a 3 layer filter to clean the circulated room air a Screen filter to remove bigger dust particles b All models active carbon filter to remove odours c 3M Filtrete filter to remove unhealthy particles from the air such as pollen bacteria animal dander and dust Selected models have the 3M Filtrete filter as standard However if you require to add this to your model or wish to purchase a replacement call Amcor for details NOTE The active carbon filter and the Filtrete filter are delivered in a plastic packaging Don t forget to install these filters These filters take away unhealthy particles out of the room environment The filter holder on the rear of the unit can be opened The active carbon filter and 3M Filtrete filter can be installed or removed The screen filter is part of the filter holder see illustration a The screen filter has to be cleaned regularly with a vacuum
6. between the ON programmed times until 24 00 The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the ON timer time then the black segments in the circular time scale will disappear OFF ON Programming the timer for OFF when the unit is RUNNING Timer example Perform the standard steps as described above The circular time scale will be on between the present time to the OFF programmed time The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the OFF timer time then the black segments in the circular time scale will disappear E Programming the timer for repeat OFF and ON when the unit is RUNNING Perform the standard steps as described above Repeat the above procedure while the digits are still flashing for setting the ON The circular time scale will be ON between 00 00 to the time set with the timer to OFF and from that time until 24 00 The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes The unit will operate daily according to the timer setting Repeat ON and OFF Programming the timer for repeat ON and OFF when the unit is NOT RUNNING Perform the standard steps as described above Repeat the above procedure while the digits are still flashing for setting the OFF The circular time s
7. c slide bar connector Controls Display onvorr 4 COOLING UP FAN down HEAT 68 58 HOURS MINUTES AAH TEMPERATURE 2 SLEEP FAN SPEED INSTALLATION WARNING Before using the air conditioner it should be left in an upright position for at least 2 hours This unit can easily be moved from one room to another In doing so keep this in mind Ensure that the unit is positioned upright on a level surface and 50 cm away from obstacles place the loose filters in the filter holder Take the filter holder out of the air conditioner Release the filter fixer and place the active carbon filter black and 3M Filtrete filter white where included in the filter holder Place the filter fixer back in the holder Place the filter holder back in the air conditioner Do not operate the unit inside the bathroom shower or in any other very humid environment Connect the hose to the unit by turning it clockwise at least 5 turns Similarly connect the hose to the slide bar connector as far as possible Place the telescopic slide bar in the open window or door and adjust the length to fill as much open space as possible Put the slide bar connector in the opening in the telescopic slide bar Close the window or door as much as possible to prevent outside air entering the room Ensure that the slide bar connector has free flow outside 50cm Im
8. cale will be OFF between 00 00 to the time set with the timer to ON and from that time until 24 00 The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes The unit will operate daily according to the timer setting After a power failure or after the unit has been unplugged you will have to program the timer settings again Cancelling the timer function In order to cancel the timer programming press the button momentarily then it will return to the time display The daily mode will be cancelled as well The black segments in the circular time scale will disappear Air flow Direct the air flow by adjusting the grill on top of the air conditioner amp Move the grill by pushing or pulling in the middle see illustration This will avoid uneven positioning of the grill Adjusting the air flow is also possible by moving the direction of the vertical louvers Sleep mode The sleep mode function adjusts the set temperature of the unit to the thermal needs of the body falling asleep as follow In the COOL or AUTO COOL mode Default fan speed LOW Press the 2 button to operate the sleep mode Press the D button again in order to cancel the sleep mode The set temperature will increase 1 C after 1 hour and a further 1 C after 2 hours No FAN mode under SLEEP mode operation Dehumidification If the unit will be used mainly as a dehumidifier just let the w
9. cleaner to avoid blocking of the air flow b The positive negative electrostatically charged 3M Filtrete filter is recommended to be changed every 3 months Unusual dirt construction work pets the presence of smoke and running the air conditioning unit continuously can shorten the life time of the 3M Filtrete filter c The active carbon filter can be cleaned with a vacuum cleaner when dusty but has to be changed at the same time as the 3M Filtrete filter Filter installation 1 2 lt 3 Slide out the filter holder from the unit Separate the filter fixer from the filter holder see fig 1 Remove the active carbon filter black and the Filtrete filter white from its plastic bag Insert the active carbon filter into the filter holder see fig 2 Insert the Filtrete filter into the filter holder see fig 3 Fix the filter by reassembling the fixer into the filter holder see fig 4 NOTE Remove the Filtrete filter and active carbon filter before seasonal storage and install new filters at the beginning of the new season The old filters can be disposed in the Non biological garbage container Replacement filter packages are available directly from Amcor To run the unit without active carbon filter and or 3M Filtrete filter does not do any harm to the air conditioner In this case odours and unhealthy dust are not removed from the circulated air The scr
10. e items such as filters The guarantee after repair or replacement will not be extended beyond the original one year period All replacement parts or units will be new or reconditioned Parts or units which are replaced become the property of Amcor Limited Amcor Limited disclaims any liability for incidental or consequential damages The warranty applies for the use of the product in UK This GUARANTEE is in addition to your Statutory Rights Creating Quality Environments AMCOR LIMITED 9 Ryan Drive West Cross Centre Great West Road Brentford Middlesex TW8 9ER UK For Customer Support Call 020 8 560 4141 AMCOR www amcorgroup com Cat nr 913123790
11. een filter must always be used 3M and Filtrete are trademarks of the 3M Company REMOTE CONTROL The unit responds to all signals that are sent by the remote control There will be a beep sound from the unit after receiving the signal The operation of the unit by remote control is almost identical to the operation by the circular control panel The only exception is the clock function Instead of the button for setting the actual time and for programming the timer there 3 push buttons the remote control as follows for setting the actual time o WR TIMER ON for programming the time when the unit is ON eee TIMER OFF for programming the time when the unit is OFF EMPTYING THE INTERNAL WATER CONTAINER Under high humidity conditions it may be necessary to empty the internal water container When the internal water container is full the backlight on the LCD display flashes The unit will switch off automatically To empty the water container do the following Switch off the unit and remove the plug from the wall socket Do not move the unit Doing this can result in water leakage damaging your floor or carpet Place the water container on the floor underneath the permanent drainage point Remove the water stopper and rubber plug from the drain and let the water run out The water container has to be emptied several times before all water will be drained 1 5 li
12. nd the cut off plug disposed of safely to prevent the hazard of electric shock There is a danger of electric shock if the cut off plug is inserted into any 13 amp socket outlet Important The wires in the mains lead on this appliance are coloured in How to wire a 13 amp plug accordance with the following code Green and Yellow Earth Neutral Brown Live As the colours may not correspond with the markings identifying the terminals in your plug proceed as follows The green and yellow wire must be connected to the terminal in the plug which is marked with the letter E or with the earth symbol or coloured green and yellow Cord clamp The blue wire must be connected to the terminal marked N or coloured black The brown wire must be connected to the terminal marked L or coloured red SAFETY INSTRUCTIONS ag IMPORTANT The unit is designed for indoor operation Rating This unit must be connected to a 220 240 V 50 Hz earthed outlet The installation must be in accordance with regulations of the country where the unit is used If you are in any doubt about the electrical installation have it checked and if necessary modified by a qualified electrician e The air conditioner is safe However as with other electrical appliances use it with care Keep out of the reach of children Do not clean the air conditioner by spraying it or immersing it in water Do not insert any object int
13. o the opening of the air conditioner Disconnect it from the mains before cleaning the unit or any of its components Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a licensed electrician Any service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to do so could result in a loss of warranty A damaged supply cord should be replaced by the manufacturer its service agent or a qualified person in order to avoid a hazard WARNING Never operate this appliance if it has a damaged cord or plug Do not lead the cord over sharp edges Don t lift or move by pushing the air conditioner at the rear but always at the front side amp VAL PARTS lt gt Air outlet 2 O Control Filter holder m xe Air inl ir inlet Carrying aa 2 handle Z gt Exhaust air Le outlet Cable storage gt mal Caster Water stopper s wheels drainage point Water container Exhaust hose Remote control 0 Air filter Slide bar Telescopi
14. portant The flexible exhaust hose can be extended from 500 to 1500 mm for mounting This length has been designed especially according to the specifications of the air conditioner Do not use an extension or exchange for a different hose as that may lead to malfunctioning The exhaust air must flow freely any blockage can lead to overheating of the air conditioner Take care to prevent any sharp bow or bend in the exhaust OPERATION ON OFF Press to switch the unit or off A buzzer will beep and the LCD will display 12 00 o clock as default Setting the clock Press the button for 3 seconds to set the clock The 2 left digits of the 4 digits on the LCD display will flash Press a to adjust the hour Press 27 momentarily the 2 right digits of the 4 digits will flash Press or to adjust the minutes of the clock Press the button for 3 seconds again to activate the clock Setting the temperature If you want to change the set temperature press 2 to set the temperature The 2 digit display will indicate the set temperature Note Reaching the set temperature depends on the room and outdoor climatic conditions Mode switch Press the button successively until the icon representing the desired mode is appearing gt Cool gt Fan gt Heat gt etc On the LCD display you will see Cooling AR Fan only Heat Each time the unit starts it starts operating in cool mode with a set
15. tres Replace rubber plug and water stopper put the plug into the wall socket and switch the unit on The warning signal should be off NOTE When the air conditioner is in use under normal circumstances the condensed water will evaporate and then be discharged through the hot air outlet hose WARNING First of all switch off the unit and remove the plug from the wall socket Clean the housing with a soft damp cloth Never use aggressive chemicals petrol detergents or other cleansing solutions Clean the screen filter regularly with a vacuum cleaner See also air filter section NOTE Never use the air conditioner without the screen filter TROUBLE SHOOTING Never try to repair or dismantle the air conditioner yourself Incompetent repairs result in loss of warranty and can endanger the user and the property Problem Cause Solution The air conditioner does not function No power supply Connect to a functioning outlet and switch on Is the LCD light flashing Empty the internal water container Timer function is active Deactivate TIMER function The air conditioner does not seem to perform In direct sunlight Windows or doors open many people or a heat source in the room Close curtains Close doors and windows place an extra air conditioner Dirty filter Clean or replace the filter s Air inlet or air outlet blocked
Download Pdf Manuals
Related Search
Related Contents
Manuel d`utilisation WV-SFN480 - Psn Fujitsu PRIMERGY TX150 S8 Portafolio docente en-línea como utilizar este manual de reparacion del motor (2zz−ge) Línea Skin - Henry Schein as800 pressure sealer - Neopost Technologies Ltd GPS satellite receiver for world wide application HP ProCurve Radio Port 210 User's Manual ホーネット 728VII+取付説明書 HP L2103AHPPhotoSmart M525 Digital Camera 6 MP 3x Opt Zoom 16MB Int MemUSED Copyright © All rights reserved.
Failed to retrieve file