1. FRONT OR THE REAR GRILLS Detail A Top Hooks Inset A Detail B Bottom Hooks i Oscillating Motor Shown Figure 3 CAUTION THE SECONDARY SUPPORT CABLE PROVIDED SHOULD BE USED ANYTIME THE CIRCULATOR IS MOUNTED OVERHEAD FOR ADDITIONAL SAFETY SECONDARY SUPPORT CABLE Figure 5 1 Loop one end of Cable around the Large Guard Wires of both the Front and Rear Grills 2 Attach a Cable Clamp with the U on the tail side of the loop leaving a tail approximately Large Guard 1 to 2 inches Tighten Clamp Nuts Make sure no part of the Cable interferes with the Blade Wires 3 Wrap the other end of the Cable around a secure building joist truss or other support near the Fan Take up all excess slack in the Cable CAUTION USE ONLY THE MOUNTING HARDWARE WHICH IS RECOMMENDED FOR USE ON THIS FAN 4 Attach the remaining Cable Clamp as indicated in Step 2 The excess tail should be trimmed to extend 1 to 2 inches past the Clamp 5 Check the Assembly to assure the Blade is free of all obstructions Figure 5 CAUTION Use of the secondary support cable does not guarantee protection against injury of persons mounting of both the circulator and cable could fail if subjected to abuse neglect or improper installation Non Oscillating Motor Shown Figure 4 OP
2. pipe for the provided threaded pipe 1 Locate the Pipe Mounting Flange securely mount to ceiling structure Ensure ceiling structure can safely support the installed Fan 2 Open one tube of Loctite 243 by snapping tube neck just below end cap Be Certain to follow all warnings noted on Loctite 243 tube 3 Apply 1 ENTIRE tube of Loctite 243 onto the first 2 threads of one end of the Threaded Pipe that will be screwed into the Motor Mounting Adapter Figure 1 Inset 4 Screw Threaded Pipe into Motor Mounting Adapter The Threaded Pipe MUST BE screwed in at least 4 full revolutions Do not allow Loctite 243 to dry before joining Tighten provided 1 4 Set Screw into Motor Mounting Adapter Figure 1 5 Open second tube of Loctite 243 by snapping tube neck just below end cap Be Certain to follow all warnings noted on Loctite 243 tube 6 Apply 1 ENTIRE tube of Loctite 243 onto the first 2 threads of the opposite end of the Threaded Pipe that is now screwed into the Motor Mounting Adapter Figure 1 Inset 7 Screw Threaded Pipe with Motor Mounting Adapter to the Pipe Mounting Flange The Threaded Pipe with Motor Mounting Adapter MUST BE screwed in at least 4 full revolutions into the Pipe Mounting Flange Do not allow Loctite 243 to dry before joining Figure 1 8 Tighten provided 1 4 Set Screw into Pipe Mounting Flange Figure 1 CAUTION FAN IS HEAVY AND MAY REQUIRE TWO PEOPLE TO MOUNT 9 Attach pull string to motor sp
3. E ASSEMBLY Figures 3 and 4 NOTE The assembly of the blade and grill is identical regardless if the Fan has an oscillating motor or a non oscillating motor One of each is shown in the illustrations below 1 Install the Rear Grill onto the Motor lining up the six holes in the grill with the six threaded holes in the Motor Install 6 10 32 X 5 16 Hex Screws through the Rear Grill into the Motor Securely tighten all 6 screws Figure 3 2 Push the Fan Blade onto the Motor Shaft centering the Hub facing away from the motor until it stops against the shaft Inset A Align Square Head Bolt with flat of the Motor Shaft TIGHTEN VERY SECURELY WITH AN ADJUSTABLE WRENCH Failure to securely tighten the Bolt could result in damage to the Fan and or personal injury 3 Hold the Front Grill so that the name in the center is right side up and straight across Starting at the top Fasten Front Grillto Rear Grill by sliding the hooked wires on the Front Grill over the outermost ring on the Rear Grill Figure 4 Detail A The bottom most hooks will require the use of a flathead screwdriver to complete assembly Stand behind the Fan Slip the flat of the screwdriver between the Front and Rear Grills next to one of the unfastened hooks Figure 4 Detail B Pull screwdriver handle upwards towards the Rear Grill Slip the Front Grill hook over the Rear Grill outer ring with a push Repeat procedure with remaining hooks CAUTION DO NOT BEND WIRES ON THE
4. ERATING INSTRUCTIONS 1 TO OPERATE Plug cord into a grounded 120V 60 Hz outlet Select desired operating speed with pull cord on the rear of the motor First pull High Second pull Medium Third pull Low Fourth pull OFF NOTE THIS FAN IS VERY HEAVY Failure to securely hold onto head assembly while adjusting head angle could result in personal injury 2 TO ADJUST HEAD ANGLE While holding head firmly loosen knob under motor turn counterclockwise Tilt head to desired position FIRMLY retighten knob under motor NOTE Motor Head Adjustment Knob and the On Off Pull Cord have the same location on oscillating or non oscialling models New 8 04 3 5084416
5. IMPORTANT INSTRUCTIONS OPERATING MANUAL FOR OSCILLATING MODELS OSCILLATION Push down oscillation knob on motor housing to make fan head move from side to side NOTE FOR OSCILLATING MODELS FAN IS SHIPPED WITH 90 OSCILLATION ANGLE FOR 45 OSCILLATION ANGLE CONNECT THE OSCILLATION LINK TO THE IN NERMOST HOLE IN THE CAM GEAR Insert A Insert A MAINTENANCE WARNING ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING WARNING DO NOT IMMERSE FAN IN WATER CLEANING Use a soft cloth and mild soap solution such as liquid dish washing detergent Dry all parts completely before reconnecting to power supply CAUTION Do not use gasoline benzine thinner harsh cleaners etc as they will damage the Fan NEVER use ALCOHOL OR SOLVENTS SERVICING All other servicing with the exception of general user maintenance should be performed by an authorized service representative Call 1 800 233 0268 Monday through Friday between the hours of 8 00 a m and 5 00 p m EST for the location of your nearest service center LUBRICATION Precision bearings are sealed at the factory for life and do not require further lubrication STORAGE Store the Fan with these instructions in a clean and dry place LIMITED WARRANTY AIRKING THREE YEAR LIMITED WARRANTY Products are warranted by AirKing to the original user against defects in workmanship or materials under normal use for three years on the motor and one year on all other parts
6. ONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 8 AM AND 4 PM EST PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE Reference the type and style of product located on the underside of the product when you call FOR TECHNICAL ASSISTANCE and SERVICE CENTER LOCATIONS For any questions comments or the location of your nearest service center PLEASE CALL OUR TOLL FREE HOTLINE AT 1 800 233 0268 MONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 8 AM AND 5 PM EST Please reference product name and model no when you call Appliance Service Dept e P O Box 569 Franklin TN 37064 PLEASE DO NOT SEND PRODUCT TO THIS LOCATION New 8 04 4 5084416 IMPORTANT INSTRUCTIONS OPERATING MANUAL Ventilation Products 24 30 OSCILLATING CEILING MOUNT FAN MODEL 9324 9335 9374 9375 24 30 NON OSCILLATING CEILING MOUNT FAN MODEL 9724 9330 9371 9370 GENERAL SAFETY INFORMATION When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following 1 Read all instructions before using Fan 2 Make certain that the power source conforms to the electrical requirements of the Fan 3 Use this Fan only as described in this manual Any other use not recommended by the manufacturer may cause fire electrical shock or injury to persons 4 To reduce the risk of personal injury and electric shock the Fan should not be played with or placed whe
7. after date of purchase Any part which is determined by AirKing to be detective in material or workmanship and returned to an authorized service location as AirKing designates shipping costs prepaid will be as the exclusive remedy repaired or replaced at AirKing s option For limited warranty claim procedures see PROMPT DISPOSITION below This limited warranty gives purchasers specific legal rights which vary from state to state LIMITATION OF LIABILITY To the extent allowable under applicable law AirKing s liability for consequential and incidental damages is expressly disclaimed AirKing s liability in all events is limited to and shall not exceed the purchase price WARRANTY DISCLAIMER AirKing has made a diligent effort to illustrate and describe the products in this literature accurately however such illustrations and descriptions are for the sole purpose of identification and do not express or imply a warranty the products are merchantable or fit a particular purpose or that the products will necessarily conform to the illustrations or descriptions Except as provided below no warranty or affirmation of fact expressed or implied other than as stated in LIMITED WARRANTY above is made or authorized by AirKing PRODUCT SUITABILITY Many states and locations have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary from those in neighboring areas While Ai
8. eed switch if desired For Oscillating Motor Place the flat section on the Motor Mounting Adapter next to the Motor Neck Figure 2A For Non Oscillating Motor Slide the Motor Neck Slot over the Motor Mounting Adapter Align the 1 2 diameter hole in the Adapter with the 1 2 diameter holes in the Motor neck Slot Figure 2B 10 Insert the 1 2 X 1 Hex Bolt 3 4 head through the Motor Neck and the Motor Mounting Adapter Place 1 2 diameter Split Lockwasher then the 1 2 diameter Hex Nut 3 4 head and tighten fully with 2 adjustable wrenches 11 From the same side of the Motor Neck insert one 1 4 20 X 1 5 8 Carriage Bolt through the Arc Shaped Slot in the Motor Neck and Hole in the Motor Mounting Adapter To Fasten Place one 1 4 Flatwasher one 1 4 Internal Tooth Lockwasher a second 1 4 Flatwasher and then tighten the Adjustable Knob over the remaining threads Oscillating Motor View Motor Figure 2A ___Mounting Adapter Figure 1 Pipe Mounting ___ N 7 _ Set Screw Flange Inset ml Threaded Pipe Loctite 243 x j Application Loctite 243 Set Screw Non Oscillating Motor View Figure 2B Motor Mounting e rian Adapter O Adapter wO e O Y 2 Exploded View for Detail Ceiling Mount Assembly New 8 04 2 5084416 IMPORTANT INSTRUCTIONS OPERATING MANUAL GRILL AND BLAD
9. n with a damaged cord or plug or after the Fan malfunctions has been dropped or damaged in any manner Return Fan to authorized service facility for examination electrical or mechanical adjustment or repair 12 Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire or damage the Fan Do not block or tamper with the Fan in any manner while it is in operation 13 Locate the Power Cord so the Fan or other objects are not resting onit Do notrun Power Cord under carpeting Do not cover Power Cord with throw rugs runners or the like Arrange Power Cord away from room traffic and where it will not be tripped over 14 This Fan is not intended for use in wet or damp locations Never locate a Fan where it may fall into a bathtub or other water container 15 Do not use Fan outdoors WARNING REDUCETHE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES CAUTION BECAUSE OF THE SIZE AND WEIGHT OF THIS FAN MAKE SURE ALL PARTS ARE COMPLETELY AS SEMBLED ACCORDING TO INSTRUCTIONS FAILURE TO DO SO COULD RESULT IN FAN COMING APART DURING OPERATION AND OR PERSONAL INJURY SAVE THESE INSTRUCTIONS New 8 04 5084416 IMPORTANT INSTRUCTIONS OPERATING MANUAL CEILING MOUNT INSTALLATION Figures 1 and 2 NOTE Distance mounted from the ceiling can be changed by using a length of 1 1 2 NPT pipe Simply substitute your
10. rKing attempts to assure that its products comply with such codes it cannot guarantee compliance and cannot be responsible for how the product is installed or used Before purchase and use of a product please review the product application and national and local codes and regulations and be sure that the product installation and use will comply with them Certain aspects of disclaimers are not applicable to consumer products e g a some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you b also some states do not allow limitations on how long an implied warranty lasts consequently the above limitation may not apply to you and c by law during the period of the Limited Warranty and implied warranties of merchantability or fitness for a particular purpose applicable to consumer products purchased by consumers may not be excluded or otherwise disclaimed PROMPT DISPOSITION AirKing will make a good faith effort for prompt correction or other adjustment with respect to any product which proves to be defective within limited warranty For any product believed to be defective within limited warranty first write or call dealer from whom product was purchased Dealer will give additional directions FOR PARTS Check package contents If parts are missing or replacement parts required please call our PARTS DEPARTMENT TOLL FREE AT 1 800 233 0268 M
11. re small children can reach it 5 Unplug power cord before servicing or moving the Fan WARNING DO NOT DEPEND UPON THE ON OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN IN STALLING OR SERVICING THE FAN ALWAYS UNPLUG THE POWER CORD 6 This Fan must NOT be used in potentially dangerous locations such as flammable explosive chemical laden or wet atmospheres 7 DO NOT use Fan in or near a window Rain may create an electrical hazard 8 Completely reassemble Fan according to instructions be fore reconnecting to power supply 9 The power cord is equipped with a three prong grounded plug that must be inserted into a matching receptacle Under no circumstances must the grounding prong be cut off the plug Where a two prong wall receptacle is encountered it must be replaced with a properly grounded three prong receptacle installed in accordance with the National Electrical Code NEC and all applicable local codes and ordinances This work must be done only by a qualified electrician using copper wire only WARNING USE OF A THREE PRONG TO TWO PRONG ADAPTER IS NOT RECOMMENDED IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTROCUTION USE OF SUCH ADAPTERS ARE NOT PERMITTED IN CANADA 10 Where possible avoid the use of extension cords If they must be used minimize the risk of overheating by ensuring that they are UL listed Never use a single extension cord to operate more than one Fan 11 Do not operate any Fa