Home
        Air King 9025 Fan User Manual
         Contents
1.    IMPORTANT INSTRUCTIONS   OPERATING MANUAL    FOR OSCILLATING MODELS   3 OSCILLATION  Push down oscillation knob on motor  housing to make fan head move from side to side     NOTE FOR OSCILLATING MODELS  FAN IS SHIPPED  WITH 90   OSCILLATION ANGLE  FOR 45   OSCILLATION  ANGLE  CONNECT THE OSCILLATION LINK TO THE INNER   MOST HOLE IN THE CAM GEAR   Inset A                  Inset A        MAINTENANCE   WARNING  ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING   WARNING  DO NOT IMMERSE FAN IN WATER    CLEANING  Use a soft cloth and mild soap solution such as liquid dish washing detergent  Dry all parts completely before reconnecting to  power supply    CAUTION  Do not use gasoline  benzine  thinner  harsh cleaners  etc  as they will damage the Fan  NEVER use  ALCOHOL OR SOLVENTS    SERVICING  All other servicing  with the exception of general user maintenance  should be performed by an authorized service representative  Call  1 800 233 0268  Monday through Friday  between the hours of 8 00 a m and 5 00 p m  EST for the location of your nearest service center   LUBRICATION  Precision bearings are sealed at the factory for life and do not require further lubrication    STORAGE  Store the Fan  with these instructions  in a clean and dry place        LIMITED WARRANTY    WHAT THIS WARRANTY COVERS  This product is warranted against defects in workmanship and or materials    HOW LONG THIS WARRANTY LASTS  This warranty extends only to the original purchaser of the product and lasts f
2.   30  NON OSCILLATING WALL MOUNT FAN  MODEL 9024  9030  9070  9071    GENERAL SAFETY INFORMATION    When using electrical appliances   basic precautions should always be followed  to reduce the risk of fire  electric shock and injury to person   including the following      s    Read all instructions before using Fan    2  Make certain that the power source conforms to the electrical  requirements of the Fan    3  Use this Fan only as described in this manual  Any other use not  recommended by the manufacturer may cause fire  electrical shock   or injury to persons    4  To reduce the risk of personal injury and electric shock  the Fan  should not be played with or placed where small children can  reach it    5  Unplug power cord before servicing  or moving the Fan     ARNING  DO NOT DEPEND UPON THE ON OFF SWITCH  AS THE SOLE MEANS OF DISCONNECTING POWER WHEN  INSTALLING OR SERVICING THE FAN  ALWAYS UNPLUG THE  POWER CORD    6  This Fan must NOT be used in potentially dangerous lo   cations such as flammable  explosive  chemical laden or  wet atmospheres    7  DO NOT use Fan in or near a window  Rain may create an  electrical hazard    8  Completely reassemble Fan  according to instructions  before  reconnecting to power supply    9  The power cord is equipped with a three prong grounded plug  that must be inserted into a matching receptacle  Under no  circumstances should the grounding prong be cut off the plug   Where a two prong wall receptacle is encountered  it must  be 
3.   Never locate a Fan where it may fall into a bathtub or other  water container    15  Do not use Fan outdoors    16 This Fan is not suitable for use in hazardous locations  Please  refer to National Electric Code  NEC  Article 500 or applicable  state or local codes or standards relating to electrical requirements  for Hazardous locations  THIS FAN DOES NOT MEET THE  REQUIRMENTS OF NEC ARTICLE 500  2002      WARNING  REDUCETHE RISK OF FIRE OR ELECTRIC SHOCK      DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED  CONTROL DEVICES     CAUTION  BECAUSE OF THE SIZE AND WEIGHT OF THIS  FAN  MAKE SURE ALL PARTS ARE COMPLETELY ASSEMBLED  ACCORDING TO INSTRUCTIONS  FAILURE TO DO SO COULD  RESULT IN FAN COMING APART DURING OPERATION AND OR  PERSONAL INJURY     5084414          IMPORTANT INSTRUCTIONS   OPERATING MANUAL    WALL BRACKET INSTALLATION  Figures 1 through 4     IMPORTANT INSTRUCTIONS   OPERATING MANUAL    require the use of a flathead screwdriver to complete assembly  Stand behind the Fan  Slip the flat of the screwdriver between the Front                                  NOTE  Always install the bracket to a minimum of 2  x 4  studding  and Rear Grills  next to one of the unfastened hooks   Figure 6   Detail B  Pull screwdriver handle upwards towards the Rear Grill  Slip the  1  Insert the 7 16 14 x 3 1 2  Bolt through Flag Bracket  Wall Bracket and into the 7 16 14 Lock Nut  Tighten with Adjustable Wrenches  MAKE Front Grill hook over the Rear Grill outer ring with a push  Re
4. 2 5084414 Rev  A 9 07 3 5084414    
5. BILITY SHALL TERMINATE  UPON THE EXPIRATION OF THE WARRANTY PERIOD    Some states and provinces do not allow limitations on how long an implied warranty lasts  or the exclusion or limitation of incidental or consequential damages   so these exclusions or limitations may not apply to you  This warranty gives you specific legal rights  You may also have other rights which vary from state to  state and province to province  Proof of purchase is required before a warranty claim will be accepted                 CUSTOMER SERVICE   Toll Free  800  233 0268  Email  producthelp  laskoproducts com  Our Customer Service team is available to assist you with product questions  service center locations  and replacement parts  They can be reached Monday  through Friday  8am 5pm Eastern  Please have your model number available  as well as the type and style  located on the underside of your product   Please  do not return product to place of purchase   Customer Service Dept   820 Lincoln Ave   West Chester  PA 19380  Please do not send product to this location   www laskoproducts com  PARTS FOR DISCONTINUED  OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE  DUETO SAFETY REASONS  MANY ELECTRONIC    COMPONENTS AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT     Rev  A 9 07 4 5084414    IMPORTANT INSTRUCTIONS      OPERATING MANUAL          Ventilation Products             24    30  OSCILLATING WALL MOUNT FAN  MODEL 9025  9035  9074  9075    24  
6. DARY SUPPORT CABLE  Figure Large Guard  PROVIDED SHOULD BE USED ANYTIME THE Wires  CIRCULATOR IS MOUNTED OVERHEAD FOR  ADDITIONAL SAFETY     SECONDARY SUPPORT CABLE  Figures 7 and 8  NY       Wall Bracket              Wall Mount Assembly Non Oscillating Motor Shown       1  Loop one end of Cable around the Large Guard Wires of both the Front and Rear  Grills    2  Attach a Cable Clamp with the  U  on the tail side of the loop leaving a tail  approximately 1 to 2 inches  Tighten Clamp Nuts  Make sure no part of the Cable    Fi  interferes with the Blade  D  Final Assembly of Motor to 3  Wrap the other end of the Cable around a secure building joist  truss  or other sup  i     Wall Mount Bracket port near the Fan  Take up all excess slack in the Cable     CAUTION  USE ONLY THE MOUNTING HARDWARE WHICH   IS RECOMMENDED FOR USE ON THIS FAN    4  Attach the remaining Cable Clamp as indicated in Step 2  The excess tail should be  trimmed to extend 1 to 2 inches past the Clamp    5  Check the Assembly to assure the Blade is free of all obstructions    CAUTION  Use of the secondary support cable does not guarantee    Detailed View of Hardware Oscillating Motor Shown protection againstinjury of persons  mounting of both the circulator and  cable could fail if subjected to abuse  neglect or improper installation        Figure 3 Figure 4                    M FN                            GRILL AND BLADE ASSEMBLY  Figures 5 and 6        NOTE  The assembly of the blade and grill is identic
7. al  regardless if the Fan has an oscillating motor or a non oscil  OPERATING INSTRUCTIONS  lating motor  1  TO OPERATE  Plug cord into a grounded 120V  60 Hz outlet  Select desired operating speed with pull cord on the rear of the motor   1  Install the Rear Grill onto the Motor  lining up the six holes in the grill with the six threaded holes in the Motor  Install  6  10 32 X 5 16  First pull  High Second Pe  ill i i ji Third pull  Low Fourth pull  OFF  epee a a a   i OFK NOTE  THIS FAN IS VERY HEAVY      g the Hub facing away from the motor  until it stops against the shaft  Inset A   Align          Square Head Bolt with flat of the Motor Shaft  TIGHTEN VERY SECURELY WITH AN ADJUSTABLE WRENCH  Failure to securely tighten Failure to securely hold onto head assembly while adjusting head angle  the Bolt could result in damage to the Fan and or personal injury  could result in personal injury   3  Hold the Front Grill so that the name  in the center  is right side up and straight across  Starting at the top  Fasten Front Grillto Rear Grill 2  TO ADJUST HEAD ANGLE  While holding head firmly  loosen knob under motor  turn counterclockwise   Tilt head to desired position  by sliding the hooked wires on the Front Grill over the outermost ring on the Rear Grill   Figure 6   Detail A   The bottom most hooks will FIRMLY retighten knob under motor     NOTE  Motor Head Adjustment Knob and the On Off Pull Cord have the same location on oscillating or non oscillating models   Rev  A 9 07 
8. or one  1  year from the date of original  purchase or until the original purchaser of the product sells or transfers the product  whichever first occurs    WHAT AIR KING WILL DO  During the warranty period  Air King will  at its sole option  repair or replace any part or parts that prove to be defective or replace  the whole product with the same or comparable model    WHAT THIS WARRANTY DOES NOT COVER  This warranty does not apply if the product was damaged or failed because of accident  improper handling or  operation  shipping damage  abuse  misuse  unauthorized repairs made or attempted  This warranty does not cover shipping costs for the return of products to  Air King for repair or replacement  Air King will pay return shipping charges from Air King following warranty repairs or replacement   ANY AND ALL WARRANTIES  EXPRESSED OR IMPLIED  INCLUDING  WITHOUT LIMITATION  ANY IMPLIED WARRANTY OF MERCHANTABILITY    LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS  THE PRODUCT  WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY  INCLUDE  I  INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER  OR  Il  REPLACMENT OR REPAIR OF ANY HOUSE  FUSES  CIRCUIT BREAKERS OR RECEPTACLES  NOTWITHSTANDING ANYTHING TO THE CONTRARY  IN NO EVENT SHALL AIR KING S LIABILITY  UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIA
9. peat procedure with remaining hooks   CERTAIN THE DIRECTION OF THE FLAG BRACKET is as shown in Figure 1  CAUTION  DO NOT BEND WIRES ON THE FRONT OR THE REAR GRILLS   2  THE HARDWARE TO ATTACH THE WALL BRACKET TO THE WALL STUD IS NOT SUPPLIED  Locate the wall stud nearest to the desired Figure 5 Figure 6  Fan location  Attach the Wall Bracket to the stud using  3  5 16  diameter x 2  long Lag Screws  g g DAA  3  Position the Flag Bracket in the Motor Neck and align the Pivot Hole with the Larger Hole in the Flag Bracket   Figure 2  Top Hooks  4  Attach pull string to motor speed switch  if desired   5  Insert the 1 2  X 1  Hex Bolt  3 4  head  through the Motor Neck  and the Flag Bracket  Place 1 2  diameter Split Lockwasher then the 1 2   diameter Hex Nut  3 4  head  and tighten fully with 2 adjustable wrenches   Figure 3  x  6  From the same side of the Motor Neck insert one 1 4 20 X 1 5 8  Carriage Bolt through the Arc Shaped Slot in the Motor Neck and Hole in 3  the Flag Bracket   Figure 3  z  To Fasten  Place one 1 4  Flatwasher  one 1 4  Internal Tooth Lockwasher  a second 1 4  Flatwasher and then tighten the Adjustable Knob    over the remaining threads  Final assembly of the Motor to the Wall Mount Bracket is illustrated in Figure 4   Figure 1 Figure 2  Detail B  Bottom Hooks   J 6 14 X 3 1 2  Bolt Non Oscillating Motor Shown Non Oscillating Motor Shown        Flag Bracket Placement of Motor to  Flag Bracket          7 16 14 Lock Nut Motor Neck       CAUTION  THE SECON
10. replaced with a properly grounded three prong receptacle  installed in accordance with the National Electrical Code  NEC   and all applicable local codes and ordinances  This work must  be done only by a qualified electrician  using copper wire only    WARNING  USE OF A THREE PRONG TO TWO PRONG   ADAPTER IS NOT RECOMMENDED  IMPROPER CONNECTION   MAY CREATE THE RISK OF ELECTROCUTION  USE OF SUCH   ADAPTERS IS NOT PERMITTED IN CANADA     Rev  A 9 07    SAVE THESE INSTRUCTIONS    10  Where possible  avoid the use of extension cords  If they must  be used  minimize the risk of overheating by ensuring that they  are UL listed  Never use a single extension cord to operate more  than one Fan    11 Do not operate any Fan with a damaged cord or plug or after the  Fan malfunctions  has been dropped or damaged in any manner   Return Fan to authorized service facility for examination  electrical  or mechanical adjustment or repair    12 Do not insert or allow fingers or foreign objects to enter any  ventilation or exhaust opening as it may cause an electric shock  or fire  or damage the Fan  Do not block or tamper with the Fan  in any manner while it is in operation    13 Locate the Power Cord so the Fan or other objects are not resting  onit  Do not run Power Cord under carpeting  Do not cover Power  Cord with throw rugs  runners  or the like  Arrange Power Cord  away from room traffic and where it will not be tripped over    14 This Fan is not intended for use in wet or damp locations 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
200GSM**  Crown XLS1000    Emerson Y690VB Drawings & Schematics    PDF(366KB)  WARNING Operations Getting Started  Sistema de Navegação Amundsen+ Manual de Instruções  Guia de instalação Start Here  C - k-factor    Copyright © All rights reserved. 
   Failed to retrieve file