Home
ACTiSYS ACT-IR100M+ Network Card User Manual
Contents
1. 19 S CONTACTINTORMA LION iane ETE EE E E 20 Copyright 2000 2008 ACTiSYS Corp Page 3 of 20 Apr 22 2008 ACTISYS Confidential Information Version 1 2 0 1 ACT IR100S L and IR100SL M ACTISYS Wireless Connectivity Expert User s Manual PRECAUTIONS To ensure trouble free operation please observe the following precautions Optical communications are easily affected by external light sources weak batteries transfer distance transfer angle etc Any of these conditions may cause a data transfer failure incomplete missing or incorrect data Make sure that the wireless interface is away from direct sunlight and other strong light source Do not terminate arbitrarily during file transfer process between DUT and computers until finished Otherwise DUT internal data integrity may be damaged which is due to the violation of DUT s Do not expose the unit to moisture as this will damage the internal circuitry Do not expose the unit to extreme temperatures It should not be placed in direct sunlight or in a closed vehicle neither should it be placed near heaters nor other heat sources Do not store the unit in a humid or dusty place Use a soft dry cloth to clean the unit Do not use a wet cloth or any solvent Do not drop the unit or handle the unit carelessly CAUTION Never touch the pins of computer connection terminal The internal circuits can be damaged by a static electricity discharge If this device requires
2. Primary Secondary Mode supported IR100S L Secondary Mode only IR100SL M Both Primary and Secondary Mode supported and mode automatically switched upon IrDA protocol negotiation with the other device Host Interface Full duplex asynchronous serial TXD RXD Or simplex TXD only and software flow control with RXD Hardware flow control RTS CTS Optional line status for link control DTR DSR Other optional inputs RI CD Designed for use in RS232C level and that it is in DTE Data Terminal Equipment configuration Host interface baud rate supported 1 2kbps 2 4kbps 4 8kbps 9 6kbps 19 2kbps 38 4kbps 57 6kbps 115 2kbps Apr 22 2008 Page 6 of 20 Version 1 2 0 1 Copyright 2000 2008 ACTiS YS Corp ACTISYS Confidential Information ACT IR100S L and IR100SL M User s Manual EM ACTISYS Wireless Connectivity Expert OVERVIEW The ACT IR100S L LM is an IrReady intelligent adapter This enables the host system with IrDA 2 communication capabilities The host system may be a serial printer a modem an industrial controller a data collector a medical instrument or any other device that may benefit from being IrDA enabled The interface between ACT IR100S L LM and the host is via a traditional asynchronous serial data port RS232C Figure 2 1 shows the system block diagram Figure 2 1 System Block Diagram ACT IR100S L IR220VACF IR8200IC RXDI 75LV4737 RXDO
3. Version 1 2 0 1 Copyright 2000 2008 ACTiSYS Corp ACTiSYS Confidential Information y T L 9 Y 9 ACT IR100S L and IR100SL M A Wireless Connectivity Expert User s Manual ACT IR100S L RS232 converter 75LV737A Buffers ACT IR8200IC L IrCOMM 9 wire OBEX Transport TinyTP TinyTP IrLMP and IAS IrLAP UARTO IrPHY encoder decoder ACT IR220VACF IrDA Transceiver Copyright 2000 2008 ACTiSYS Corp Page 9 of 20 Apr 22 2008 ACTIiSYS Confidential Information Version 1 2 0 1 ACT IR100S L and IR100SL M User s Manual ACTISYS Wireless Connectivity Expert OPERATION SETTING EEPROM amp OTHER OPTIONAL HARDWARE Serial EEPROM 4 4 1 There are some special functions if the external serial EEPROM installed The optional serial EEPROM allow users to set Host Speed and Hardware Flow Control and Connection Control The system initial sequence are shown below System Power ON Serial EEPROM data is available Blinking LED To get the Jumper setting Setting Host Note The serial EEPROM setting can override jumper settings Copyright 2000 2008 ACTiSYS Corp ACTISYS Confidential Information Page 10 of 20 Apr 22 2008 Version 1 2 0 1 ACT IR100S L and IR100SL M ACTISYS Wireless Connectivity Expert User s Manual 4 2 Baud Rate Setting Jumpers SELO 2 and serial EPROM settings are used to set the host interface RXD and TXD data rate Note that this is independent of
4. ACTISYS The Wireless Connectivity Expert 921 Corporate Way Fremont CA 94539 USA Tel 1 510 490 8024 Fax 1 510 623 7268 IrReady Website http www actisys com E mail irda info actisys com ACT IRIO0S L amp ACT IRIO0SL M IrReady Intelligent Adapter User s Manual April 22 2008 Ver 1 2 0 1 Copyright 2000 2008 ACTiSYS Corporation All Rights Reserved ACT IR100S L and IR100SL M ACTISYS Wireless Connectivity Expert User s Manual This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation WARNING FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user authority to operate this equipment NOTE This equipment has been tested and found to comply with the limits for Class B digital device pursuant to Part 15 of the FCC Rules This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will nor occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can
5. Rewestioser f 0 ors eros i BLUNT NN NN EE NN o a LA ELEM Copyright 2000 2008 ACTiSYS Corp Page 15 of 20 Apr 22 2008 ACTiSYS Confidential Information Version 1 2 0 1 A Ti 9 YS ACT IR100S L and IR100SL M Wireless Connectivity Expert User s Manual 5 HOW TO CONNECT IR100S L LM WITH HOST DEVICE IR100S L LM uses a standard RS232 DTE port to connect with the host If the host device is a Modem like device and has a RS232 DCE port then use a straight cable That is connect the signals with the same name from one side to the other Copyright 2000 2008 ACTiSYS Corp Page 16 of 20 Apr 22 2008 ACTiSYS Confidential Information Version 1 2 0 1 ACT IR100S L and IR100SL M User s Manual SACTISYS Wireless Connectivity Expert If the host device is a PC like device and has a RS232 DTE port too then you need to use a Null Modem connection between the two That is in out signal pairs need to be crossed Page 177 of 20 Copyright 2000 2008 ACTiSYS Corp ACTiSYS Confidential Information Apr 22 2008 Version 1 2 0 1 ACT IR100S L and IR100SL M LL ACTISYS Wireless Connectivity Expert User s Manual 6 OTHER ACTiSYS IrDA PRODUCTS CTi ACT 1 IrDA Primary Station Protocol Stack IrLAP IrLMP IAS and optional Tiny TP IICOMM IrMC IrTran P etc For PDA digital camera handheld data terminal palmtop computer smart phone Very tight code modular design easy porting and API int
6. any servicing use only an ACTISYS service dealer an ACTISYS approved service facility or an ACTISYS repair service e When exchanging data with host computer be sure the appropriate serial communication port is available and is not in conflict with other peripheral device or software Page 4 of 20 Apr 22 2008 Copyright 2000 2008 ACTiSYS Corp Version 1 2 0 1 ACTISYS Confidential Information A TiS YS ACT IR100S L and IR100SL M Wireless Connectivity Expert User s Manual REVISION HISTORY Revision History LN NENNEN MN 1 2 0 1 4 22 2008 Reformatted amp update Corporate Address ACTiSYS reserves the right to make changes without further notice to any products herein to improve reliability function or design ACTiSYS does not assume any liability arising out of the application or use of any product or circuit described herein All trademarks logos organization amp company names and product model names are owned by the respective organizations or companies Copyright 2000 2008 ACTiSYS Corp Page 5 of 20 Apr 22 2008 ACTiSYS Confidential Information Version 1 2 0 1 ACT IR100S L and IR100SL M ACTISYS Wireless Connectivity Expert User s Manual 1 FEATURES Support IrDA standard including IrLAP IrLMP TinyTP IrcOMM IIOBEX transport Other standards rLPT IrDA baud rate supported 9 6kbps 19 2kbps 38 4kbps 57 6kbps 115 2kbps
7. flow control HOST data flow control and baudrate is not obey IrCOMM control parameters Apr 22 2008 Page 13 of 20 Version 1 2 0 1 Copyright 2000 2008 ACTiSYS Corp ACTISYS Confidential Information A T LS YS ACT IR100S L and IR100SL M AE Wireless Connectivity Expert User s Manual 4 6 OnLine Change Host Speed and Hardware Flow Control Connection Control The ACT IR100S L LM allowed user to change Host Speed or Hardware Flow Control Connection Control in run time IRSET can change setting and write new value into the EEPROM via IR IR SETTING v1 01 ox H5 232 Baudrate bps C 1200 19200 C 2400 38400 C 4800 7 57600 C 9600 115200 lanere TS to el C YES ND IF received done COMSET can change setting and write new value into the EEPROM via COM port L COM SETTING v1 01 fel ES Ignore OSA C COM C YES tf NO H5 232 Baudrate bps cC 17200 38400 C 2400 e 57600 C 4800 e 115200 C 600 Ignore CTS gt C YES v NO mm IR 1005 L READY Copyright 2000 2008 ACTiSYS Corp Page 14 of 20 Apr 22 2008 ACTiSYS Confidential Information Version 1 2 0 1 y T LS YS ACT IR100S L and IR100SL M AE Wireless Connectivity Expert User s Manual 4 7 RS 232C DTE DB 9P Connector Pin No Name Descriptions c Daa Camer Med RO rewera 06 resero 0 Dm pae Tena Ready 0 exo semi GND osr paesane ANN WS
8. the IrDA connection data rate Data format is always 8 data bits no parity and 1 stop bit Note that this is compatible with end to end data format using 7 data bits parity and 1 stop bit That is the application at both end of the IrDA link may generate and check parity if 7 data bit is used The Host Interface can operate on eight different baud rates from 1 2kbps to 115 2kbps SEL7 SELO D12 D5 1 None 0 Install DIODE 1N4148 PCB bottom view Jumpers Baud Rate SEL2 SEL1 1 2kbps 2 4kbps 4 8kbps 9 6kbps 19 2kbps 38 4kbps 57 6kbps 115 2kbps Copyright 2000 2008 ACTiSYS Corp Page 11 of 20 Apr 22 2008 Version 1 2 0 1 ACTiSYS Confidential Information ACT IR100S L and IR100SL M e ACTISYS Wireless Connectivity Expert User s Manual 4 3 Ignore DSR dT SEL3 open means ignore the physical DSR input pretend that DSR is on This logical DSR is always used for connection control The physical DTR is used for connection indication SEL3 has no effect on DTR When SELS3 close DSR is used for connection control Active DSR permits IrDA connection Inactive DSR forbids new connection and terminates existing connection Jumper Ignore DSR SELS3 Descriptions DSR is used for IR connection control 4 4 Ignore CTS SEL4 open means ignore the Physical CTS input pretend that CTS is on This logical CTS is always used for TXD flow control The physical RTS is used for RXD flow control S
9. CT IR100S L and IR100SL M Wireless Connectivity Expert User s Manual TABLE OF CONTENTS PRECAUTION asters os sc sas Irvine MINI evi bend Mc E DM IM eM tI VENUE 4 REVIDON ES TORY 2esutiomite EDU DERIT vRSDHMTOI idm Me MM UIN EIN EINE 5 LR E OST dO E 6 RONCE c T T smog Leur Mc 8 3 1 Embedded IrDA DEOUGGOL SES E issena T 8 3 2 SIR IrPHY encoder decoder esses nn nnn n eser enne nennen 8 4 0OPERATION SETTING EEPROM amp OTHER OPTIONAL HARDVWARE ne 10 4 1 eral Fe ie DL MT 10 4 2 Baud REO DOLEO Goose rie paeti ibis dae ren dti va vid um abad E ed oone Fondi hanna FUR Uu dSPU IDE 11 4 3 Poor IE RR m 12 4 4 20 2 041 r 12 4 5 EEPROM Function Disable o oria pi o PrEI OUR oxEi ai ere A R 13 4 6 On Line Change Host Speed and Hardware Flow Control Connection Control 14 4 7 H5 2592C DLE DB OP COBlDeCDOE iueiedesessentozunssatedesense ddacencdunwaensatedensscausevesedevermasotincsecatess 15 5 HOW TO CONNECT IR100S L LM WITH HOST DEVICE eere 16 6 OTHER ACTISYS IrDA PRODUTQCTS ec cccccccsecccncceeesccensceeecceececnecseeceeecceenseeeeceeeesss 18 8 PERT NPY
10. EL4 has no effect on RTS When SEL4 close CTS is used for flow control of TXD Active CTS permits TXD Inactive CTS forbids TXD Descriptions Ignore CTS Ignore CTS input CTS is used for RXD flow control Apr 22 2008 Page 12 of 20 Version 1 2 0 1 Copyright 2000 2008 ACTISYS Corp ACTiSYS Confidential Information ACT IR100S L and IR100SL M L ACTISYS Wireless Connectivity Expert User s Manual 4 5 EEPROM Function Disable Jumper SEL7 is use to enable or disable EEPROM function If this function disable IR100S L LM will use SELO SEL4 setting only If this function enable IR100S L LM will use EEPROM setting and jumpers SELO SEL4 are ignored Jumper Descriptions Function SEL7 Disable ooo Disable EEPROM function Enable Enable EEPROM function Note 1 SEL5 SEL6 are reserved for future use 2 Independent of the SEL3 or SEL4 software flow control is automatically used and DTR always active during IrLPT connection this is used for printer host In this case if RXD received an X OFF TXD transmission is blocked If RXD received an X ON TXD transmission may resume In addition hardware flow control may also be enabled 3 For IrLPT XON XOFF flow control is always enabled This is independent of SEL3 or SEL4 4 In ICOMM 9 wire connection IR100S L always response DCE line status if line state is changed or response Poll for Line Settings via IrLMP control channel Independent of the IR
11. TXDO TXD TXDO RTSO DTRO RS232C Jumpers for Host baud rate setting and flow control etc Apr 22 2008 Version 1 2 0 1 Page 7 of 20 Copyright 2000 2008 ACTiSYS Corp ACTiSYS Confidential Information ACT IR100S L and IR100SL M ACTISYS Wireless Connectivity Expert User s Manual 3 APPLICATIONS 3 1 Embedded IrDA protocol stack The mandatory IrDA protocol layers IrLAP comply with TEST frame capability requirement and IrLMP including IAS are handled by ACT IR100S L LM In addition TinyTP IICOMM IrLPT IIOBEX transport are all included The incoming outgoing IrDA user data payload are buffered and then transferred to from the host The baud rates of IrDA traffic and host interface are independent of each other The flow controls of IrDA traffic and host interface are also independent of each other 3 2 SIR IrPHY encoder decoder The ACT IR220VACF chip use in this adapter is an IrPHY encoder decoder It translates UART or RS232 NRZ signals to from IrPHY SIR code RZI modulation The ACT IR220VACF is a half duplex infrared communication processor for exchanging data from IR and RS232 ACT IR220VACF cover data baud rate between 9 6kbps and 115 2kbps The IrPHY specification allows two kinds of modulations 3 16 of a bit duration pulse or minimum pulse duration of 1 63 us we use minimum pulse duration of 1 63 us to modulation bit data Apr 22 2008 Page 8 of 20
12. be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Increase the separation between the equipment and receiver Reorient or relocate the receiving antenna Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment is in the 2nd Class category information equipment to be used in a residential area there to and conforms to the standards set by the Voluntary Control Council For Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in such residential area When used near a radio or TV receiver it may become the cause of radio interference Read the instructions for correct handling NOTE Must be used with shielded cable only FOR YOU RECORDS For your assistance in reporting this product in case of loss or theft please record below the model number and serial which are located on the bottom of the case Please retain this information Model Number Date of Purchase Place of Purchase All indicated copyrights and trademarks in the following pages are copyrights and trademarks of their Respective corporations Copyright 2000 2008 ACTiSYS Corp Page 2 of 20 Apr 22 2008 ACTiSYS Confidential Information Version 1 2 0 1 A Th 9 YS A
13. erface well supported omall code size 20 40K bytes well tested and inter operate with all IrDA devices CTi II ACT 2 IrDA Secondary Station Protocol Stack IrLAP IrLMP IAS and optional Tiny TP IICOMM IrMC IrTran P etc For printer pager docking station medical device cell phone storage devices Very tight code modular design easy porting and API interface well supported omall code size 4 20K bytes well tested and inter operate with all IrDA devices C CTi 100M IrDA Printer Adapter ed Attached to and works well with any parallel printers IR wireless printing directly from your IrDA devices Automatic switch between mobile IR and desktop cable based printing LED indicate transmission speed and printing status CTi 220L L IrDA Com Port Serial Adapter Connects to the serial port on any computer No power eeded Data transfer wirelessly from IrDA mobile devices Model already built into Windows 95 98 2000 IR driver IR distance from 0cm 200cm with no external power fr 2000U FIR USB Adapter Plugs into any desktop PC USB port Gives you the full IrDA speeds from 9 6K to 4M bps wom e Meets both USB 1 1 and IrDA 1 1 specification inr e Bundled with drivers for Windows 98 and Windows 2000 i e USB bus powered requires no external power supply Copyright 2000 2008 ACTiSYS Corp Page 18 of 20 Apr 22 2008 ACTISYS Confidential Information Version 1 2 0 1 ACT IR100S L a
14. es do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described above or to extend the duration of any warranties beyond the time period described above on behalf of ACTISYS Corporation The warranties described above shall be the sole and exclusive remedy available to the purchaser Correction of defects in the manner and for the period of time described above shall constitute full satisfaction of all claims whether based on contract negligence strict liability or otherwise In no event shall ACTiSYS Corporation be liable or in any way responsible for any damages or defects in the Product which were caused by repairs or attempted repairs performed by anyone other than ACTiSYS technician Nor shall ACTISYS Corporation be liable or in any way responsible for any incidental or consequential economic or property damage Some states do not allow the exclusion of incidental or consequential damages so the above exclusion may not apply to you Copyright 2000 2008 ACTiSYS Corp Page 19 of 20 Apr 22 2008 ACTiSYS Confidential Information Version 1 2 0 1 ACT IR100S L and IR100SL M User s Manual E ACTISYS Wireless Connectivity Expert CONTACT INFORMATION ZO NY AZ The Wireless Infra red Expert IrDA Protocol Software For Portable Devices IrDA Test Software F
15. nd IR100SL M ACTISYS Wireless Connectivity Expert User s Manual 7 WARRANTY ACTiSYS Corporation warrants to the first consumer purchaser for a period of 1 year from the date of purchase that this wireless interface The Product Will be free from defective workmanship and materials and agrees that it will at its option either repair the defect or replace the defective Product or part thereof at no charge to the purchaser for parts or for labor This warranty does not apply to any appearance items of the Product any consumable items such as paper ink ribbon or batteries supplied with the Product or to any equipment or any hardware software firmware or peripheral other than the Product This warranty does not apply to any Product the exterior of which has been damaged or defected which has been subjected to misuse abnormal service or handling or which has been altered or modified in design construction or interfacing Tampering With Label Voids Warranty In order to enforce the rights under this limited warranty the purchaser should mail ship or carry the Product together with proof of purchase to ACTISYS The limited warranty described above is in addition to whatever implied warranties may be granted to purchasers by law To the extent permitted by applicable law ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR USE ARE LIMITED TO A PERIOD OF 1 YEAR FROM THE DATE OF PURCHASE Some stat
16. or Hardware Systems IrDA Printer And Computer Adapters 8 L Il5 2K 4M and IGM bps e w 2 E es Tia E Tre IR220L L IR100M 1000M ACTiSYS Corporation 921 Corporate Way Fremont CA 94539 USA TEL 1 510 490 8024 FAX 1 510 623 7268 E Mail irda info actisys com Web http www actisys com Apr 22 2008 Version 1 2 0 1 Page 20 of 20 Copyright 2000 2008 ACTiSYS Corp ACTISYS Confidential Information
Download Pdf Manuals
Related Search
Related Contents
User Guide - Dezidata TVE GmbH Telstra International Roaming Pocket Guide (PDF 364KB) LISTSERV Maestro 4.0 Customization Manual - L Guía del Usuario 取扱説明書ダウンロード(PDF) A user's guide to optimal transport Copyright © All rights reserved.
Failed to retrieve file