Aarrow Fires TF 70 Stove User Manual

image

Contents

1. Im DU mm D Ne CENTRAL HEATING RETURN 22mm PIPE IRCULATING PUMP DRAIN COCK AT LOWEST POINT Note Diagrammatic representation only Design and calculations for individual systems should always be carried out by a qualified heating engineer Stratford Tf amp Ti Boiler Multifuel Stoves 23 INSTALLATION Central Heating and Domestic Hot Water System Using Three Boiler Tappings INJECTOR TEE DOMESTIC HOT WATER RETURN 28mm PIPE 22mm OPEN VENTS CENTRAL HEATING FEED AND COLD WATER TANK a COMMON RETURN TO e TN X s RETURN BOILER 28mm PIPE RADIATORS DOMESTIC HOT WATER INDIRECT HOT WATER TANK GRAVITY RADIATOR Te PIPE STAT GRAVITY FLOW 28mm PIPE GRAVITY RETURN 28mm PIPE SCH e CENTRAL HEATING RETURN 22mm PIPE IT d CIRCULATING PUMP DRAIN COCKAT LOWEST POINT INJECTOR TEE Central Heating System Without Domestic Hot Water Using Three Tappings INJECTOR TEE DOMESTIC HOT WATER RETURN 28mm PIPE Y CENTRAL HEATING m COMMON RETURN TO RETURN BOILER 28mm PIPE ED 22mm OPEN VENT 1 CENTRAL HEATING RETURN 22mm PIPE ap x T CIRCULATING PUMP DRAIN COCK AT LOWEST POINT INJECTOR TEE Note Diagrammatic representation only Design and calculations for individual systems should always be carried out by a qualified heating engineer
2. OVER FIRING Do not over fire your appliance Using flammable liquids or too much wood or firing the fire at maximum for prolonged periods may result in over firing If the chimney connector or casing glows red it is being over fired If this occurs immediately close all air inlets to the appliance to reduce the air supply to the fire Should a chimney fire occur immediately close the appliance down Get everyone out of the house and call the fire Stratford Tf amp Ti Multifuel Boiler Stoves OPERATING INSTRUCTIONS brigade A chimney fire may cause structural damage of the chimney Do not use the appliance until the chimney and connector have been inspected and any damaged parts repaired or replaced This should be done by a competent person such as a HETAS registered engineer CLEANING IMPORTANT Under some circumstances soot can quickly build up on the throat plate and adjacent areas The throat plate should be removed and checked monthly and any debris stripped off Similarly clean the upper surface of the firebox Refer to page 16 for instructions on throat plate removal inspection IF ASH BUILDS UP AROUND THE THERMOSTAT OPENING 1 Make sure the fire is unlit and cold 2 Remove the access plate See page 19 Carefully clean the cold ash from the thermostat using a vacuum cleaner Re fit the access cover Also the area to the left hand side of the firebox should be swept clean WARNING PERFORM THESE OPERATIONS WH
3. 002 AFS003 AFS003 4 Hot Plate AFSO010 AFS012 AFS012 N A 5 Operating Tool gt AFS008 AFS008 AFS008 AFS008 AFS008 6 Ashpan AFS050 AFS050 AFS052A AFS116 AFS054 7 Flue Spigot AFS009 AFS009 AFSO11 AFSO11 N A Stratford Tf amp Ti Boiler Multifuel Stoves 31 PARTS LIST E Visual Aid Tf 30b Tf 50b Tf 70b Tf 90b Ti 40b not to scale Part No Part No Part No Part No Part No 8 Airwash AFS1077 AFS1077 AFS1077 AFS1077 AFS1077 9 Glass Replacement Kit Ge with AFS088 AFS090 AFS090 AFS090 088 Gasket 10 Glass Clips amp Gasket pan AFS089 AFS091 AFS091 AFS091 AFS089 11 Hinge kit Comprises 2 Hinges amp 4 Fixings Per Set d D 4 AFS047 AFS047 AFS047 AFS047 AFS047 12 Fire Door Rope Kit Complete with Door Rope Glue 048 AFS048 AFS048 AFS048 AFS048 13 Main Door Assembly Complete with Handle Glass A AFS200 AFS201 AFS0201 AFS201 AFS200 Gaskets Clips and Seal 14 Decorative Door Surround AFS095 AFS096 AFS096 AFS096 AFS095 32 Stratford Tf amp Ti Multifuel Boiler Stoves PARTS LIST PartDescription Visual Aid Tf 30b Tf 50b Tf 70b Tf 90b Ti 40b Re not to scale Part No Part No Part No Part No Part No 15 Fire Door Te 39 AFS204 AFS204 AFS204 AFS204 AFS204 16 Thermostat Assembly Includes A ET Damper Fixing amp AFS020
4. AFS020 AFS020 AFS020 AFS023 Control Knob 17 Thermostat Control Knob AFS022 AFS022 AFS022 AFS022 AFS022 18 Thermostat Damper Plate e AFS021 AFS021 021 AFS021 AFS021 Sa 19 Fire Bed www Surround LEET AFS007 AFS007 AFS007 AFS007 AFS007 20 Comb replacement with extension shaft AFS168A AFS170A AFS0172A AFS172A AFS062 21 Spare side trims for Ti40 N A N A N A N A AFS1147 22 Replacement slot in grate bar rear MMMM AFS075A AFS077A AFS082A 082 079 landing 23 Replacement T 29 Interlock EN AFS015A AFSOISA AFSOISA AFSOISA AFS015A Stratford Tf amp Ti Multifuel Boiler Stoves 33 GUARANTEE Guarantee Once again we would like to thank you for buying a Stratford multifuel boiler stove When you buy an Stratford stove you are not only buying a first class appliance you are buying a commitment from us to look after you and your appliance for as long as you want Your Stratford stove carries a decreasing guarantee against manufacturing defects for a period of three years from date of purchase providing the registration card has been completed and returned to Arada otherwise only a one year guarantee will apply The three years guarantee applies to the main body of the fire i e the steel carcass and items fixed immovably thereto The external paint finish and thermostat carry a one year guarantee Arada Ltd cannot guarantee items which are sus
5. Aarrow Operating amp Installation Manual Stratford Tf amp Ti Multifuel Boiler Stoves Stratford Tf 70 Boiler Stove With optional stand PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Arada Ltd Rev 6 The Fireworks Nov 2006 Bridport Part No AFS1121 Dorset DT6 3BE Great Britain Tel 44 01308 427234 Fax 44 01308 427441 www aarrowfires com Congratulations on your choice of an Aarrow Stove More than 20 years experience has been put into the development of our Stratford Family to ensure ultimate performance and years of trouble free enjoyment Every detail on the fire has been carefully engineered and designed which is why we are so confident in the reliability of our product Should you have any questions about our Stratford Stoves that are not covered in this manual please contact the Aarrow dealer in your area or call our Technical support department on 01306 427234 O COPYRIGHT 2003 Arada Ltd This booklet has copyright amp may not be copied in whole or part used for any purpose other than that for which it is supplied without express written consent from Arada Ltd CONTENTS Page Page INTRODUCTION INSTALLATION Safety Notices S General Precautions 15 The Principle of the Fire S Combustible Materials 15 Check List 6 Multifuel Grate amp Grate Bars 16 Technical Data 7 Throat Plate Inspection 16 OPERATING INSTRUCTIONS Flue Outlet and Hotplate 17 Multifuel Grate 8 Flues and Chi
6. THE THERMOSTAT HAS BEEN FITTED AND CORRECTLY SET AT MANUFACTURE SO THE FOLLOWING PROCEDURES WILL ONLY BE REQUIRED WHEN REPLACING OR RE SETTING THE THERMOSTAT Stratford Tf amp Ti Boiler Multifuel Stoves INSTALLATION To fit remove thermostat on Tf models For fitting removal of thermostat on Ti models please see page 20 1 Pull thermostat knob off of the shaft 2 Remove access cover plate use a No 2 Pozi screw driver and remove the 2no CSK M5 screws 3 Remove the 2no M5 screws that secure the thermostat housing The thermostat is now free and you will be able to remove the spacer bracket 4 On the rear of the stove remove the thermostat sensor from its pocket and push this carefully through the hole in the corner cut out of the stove Take care not to kink the copper tube 5 Withdraw the thermostat from the apperture 6 If you are fitting a new thermostat you will need to remove the knob extension shaft Use a 7mm spanner To remove the M4 Grub screw 7 Re fit is the reverse of the above process Please ensure the spacer bracket is secured beneath the thermostat as in point 3 See below if adjustment is required ADJUSTMENT OF THE THERMOSTAT However it is advisable to check the cold setting distance prior to lighting a fire in it With the control set at maximum there should be a gap of 23mm between the fire and the edge of the damper plate furthest from the control shaft If this is not the case
7. control knob to position 8 Light in the normal manner with paper and kindling or use a fire lighter f using a gas poker be sure to remove it immediately the fire is alight When the fire is well alight regulate the burning rate by adjusting the setting on the thermostat control knob The air wash can be opened sufficiently to keep the door glass clean BURNING WOOD Set air wash to fully open position Proceed as for solid fuel but note the fire will burn up and become established more quickly MIXED FUELS As per coal but allow additional secondary air ANTHRACITE Anthracite is more difficult to keep in for long periods consequently more care in setting the controls and some familiarisation is necessary when burning anthracite Use the smallest size fuel Stovesse or Small Nuts Proceed as for manufactured smokeless fuel Leave the air inlet control open about a quarter or less Note The high temperature paint acquires durability by being cured during the initial firings of the appliance will give off fumes which are non toxic but which certain persons may find have an unpleasant or irritant effect Ensure that the area is well ventilated during this time 12 OVERNIGHT BURNING The appliance will burn overnight provided Sufficient fuel is placed in the firebox The controls are set correctly Excess draught is not present in the chimney Close the door If the fire goes out with unburnt fuel l
8. lugs Step 2 Slide the two glass retainer clips on one side only inwards towards the centre of the door as far as they will go Step 3 Pull this side of the glass away from the door casting easing the tags on the glass retaining clips past the edge of the aperture in the door casting OPERATING INSTRUCTIONS Step 4 Remove the glass completely Store glass retaining clips and white gasket 1f sound safely for re use Step 5 Follow this procedure in reverse to fit replacement door glass or gasket GLASS E A GLASS CLIP GASK ET FIRE DOOR Ss SS Fig 6 DOOR ADJUSTMENT The catch can be adjusted by sharply tapping the catch on the inside of the door Once the appliance has been under fire for a period of time the fire door may appear to have moved out of alignment with relation to the door aperture or catch on the door interlock mechanism This is quite normal and due to the settling of the casing The fire door can be re aligned by the user as follows When the appliance is cold open the fire door so that it is at a right angle to the front face of the fire Lift the fire door up off the hinges 10 Gently tap the two hinge pins in a direction to compensate for the misalignment fig 7 Fig 7 Refit the door and check to ensure it now sits square to the body if not repeat above steps Raising the door as follows When the appliance
9. of high speed preheated air behind the glass to help keep it clean and to provide secondary air over draught The provision of two inlets on all multifuel stoves gives a wide range of primary air secondary air under draught over draught combinations The optimum settings will only be established by experience in firing the appliance and will depend on type of fuel the position of the appliance in the house condition of chimney etc CHECK LIST Inside the appliance you should find the following Part Description amp Visual Aid Stratford Stratford Stratford Stratford Stratford Tf 30b Tf 50b Tf 70b Tf 90b Ti 40b not to scale 1 Fuel retainers EL lt a 2 2 2 2 2 2 Grate bars fc SR 5 7 9 9 7 3 Throat plate MW E 1 1 1 1 1 4 Flue spigot 1 5 1 5 1 6 1 6 N A 5 Hot plate 1 5 1 5 1 6 1 6 N A 6 Ash pan 7 Operating tool 15900 8 Fire bed supports _ 9 Fire door handle 10 Instructions 6 Stratford Tf Ti Multifuel Boiler Stoves TECHNICAL DATA Stratford Stratford Stratford Stratford Stratford EE Tf 30b Tf50b Tf70b Tf90b Ti40b Max output to room kW 2 2 9 3 5 4 5 2 BTU s 6 840 8 550 11 970 15 390 6 840 Max output to water kW 7 5 13 17 5 24 12 5 25 000 45 000 60 000 82 000 43 000 Number of radiators in avera
10. record chart Stratford Tf amp Ti Multifuel Boiler Stoves 35 FINAL FACTORY CHECK LIST DL EI A ms checked it mue ore and it s pomme oo AI A El FRE BED SURROUNDS Den mmok o Des A CS E OPERATING NSTRUCTIONS Please ensure the enclosed registration card is completed and returned to Arada and the following informa tion completed for your own information Assembled By edes Ghecked ao esc ERN Date of Please ensure installer completes BOILER CHECK LIST on page 29 and INSTALLATION CHECK LIST details on page 30 of this manual BK029
11. spray as some paints interact This could ruin the finish and invalidate the guarantee Stratford Tf amp Ti Multifuel Boiler GENERAL PRECAUTIONS Note All installations must conform to the appropriate building regulations The Building Regulations for England and Wales 2000 ref Approved Document J 2002 edition issued by the DTLR The Building Standards Scotland Consolidation Regulations Detailed recommendations for installation of appliances chimneys and flues are outlined in the current issue of the following British Standards BS6461 BS8303 and BS4543 Any Manufacturer s Instructions must not be taken as overriding statutory requirements During installation ensure that adequate precautions are taken to avoid unnecessary risk to yourself or any householder In particular the danger from the caustic nature of the fire cement should be avoided by using these accepted methods Wear gloves when handling fire cement Wear goggles when chiselling or looking up chimneys Make sure that Building Regulations are adhered to during installation along with any local by laws In the case of heating systems make sure that the pipe work is correctly bonded to ensure electrical earthing HANDLING By the time you read this you will appreciate the weight of the appliance The Safety and handling guidelines as set out on page 5 of this manual should be followed To make movement easier internal fittings fuel reta
12. E National Association of Chimney Engineer telephone 0800 0924019 www nace org uk or NACS National Association of Chimney Sweeps telephone 01785 811732 www chimneyworks co uk Stratford Tf amp Ti Multifuel Boiler INTEGRAL BOILERS Integral boilers should be connected with flow and return connection of any circuit on opposite sides of the appliance cross flowed to an indirect hot water tank system adding Fernox or similar corrosion inhibitor to prevent corrosion and the formation of lime scale It is also essential that the return water temperature remains in excess of 45 degrees centigrade Celsius The gravity return should be fitted with a thermostat which will activate a cut out on the radiator circulating pump should the temperature drop below this level Connect pipe work to the boiler unit The connected pipes should be screwed to a maximum depth of 15mm from the face of the tapping female 1 B S R Steel integral boilers should be connected to an indirect hot water tank system Note the flow and return sections of any circuit must always be opposite of appliance Remember to incorporate a draining plug tap at the lowest point to facilitate drainage amp flushing Warning if a pipe stat is not fitted then cold water corrosion can occur FAILURE TO COMPLY WITH THESE REQUIREMENTS WILL INVALIDATE THE GUARANTEE CHECKING THE THERMOSTAT AND PRESETTING TO THE CORRECT DAMPER PRESSURES PLEASE NOTE
13. EN THE STOVE IS UNLIT AND COLD ACCESSORIES STANDS Elegant stands are available for the Stratford free standing fires Stands are not available for the inset models These increase the height of the appliance and rear flue outlet by approximately Tf 30 by 125mm Tf 50 by 130mm Tf 70 by 135mm Tf 90 by 140mm TRACERIES For added decorative effect beautiful door traceries are available for the complete Stratford fires range PAINT Matching aerosol paint to tone in any connecting flues pipes or surrounding metalwork 13 SERVICING MAINTENANCE It is important that your fire is regularly serviced in accordance with these instructions This should be carried out at least annually by a qualified person and should consist of the following When the appliance is cold and unlit ensure to remove the firebrick liners and throat plate Inspect all gasketing on doors glass etc and re order any Items that may need replacing from your Aarrow dealer With a wire brush clean inside the appliance paying particular attention to the small inlet holes of the air wash on the inside above the fire door and to the door With Ti40 models ensure to sweep up around the damper flap regularly to avoid ash build up Sweep the chimney and confirm that it is sound Examine all joints in the flue pipe etc and re seal if necessary Reassemble and leave with the air inlet and air wash control about half way open This will allow a free flow o
14. RADIATORS IN GRAVITY FLOW 8mm PIPE GRAVITY RADIATOR X PIPE STAT GRAVITY RETURN 28mm PIPE 24 Stratford Tf amp Ti Multifuel Boiler Stoves BOILER TAPPING POSITIONS Stratford Tf30 Boiler Tapping Positions e 284 00 345 00 384 00 Stratford Tf50 Boiler Tapping Positions m 383 00 378 00 484 00 All dimensions in mm Stratford Tf amp Ti Multifuel Boiler Stoves 25 BOILER TAPPING POSITIONS Stratford Tf70 Boiler Tappings Positions E 432 00 400 00 285 00 580 00 Stratford Tf90 Boiler Tappings Positions Sa 432 00 400 00 285 00 580 00 26 All dimensions in mm Stratford Tf amp Ti Multifuel Boiler Stoves BOILER TAPPING POSITIONS Stratford Ti 40 Inset Boiler Tapping Positions p450 50 gac 2 Y i o 300 00 o Q O 224 50 165 00 All dimensions in mm Stratford Tf amp Ti Multifuel Boiler Stoves 27 INSTALLATION WATER CONNECTIONS Heating systems The size of the heating system which can be run will depend on the output rating of the appliance It will be necessary to work out heat loss calculations for the system proposed in order to establish the kW hr rating An appliance that will meet this figure can then be chosen for boiler outputs please refer to the brochure The constructional requirements of installing and connecting the applia
15. When warm the flue draught should be between 0 1 and 0 2 mb A chimney may comply with the regulations but still be subject to down draught and similar problems A chimney terminating above the ridge level is generally less likely to suffer such problems If a new chimney is being provided it should fully comply with the relevant Building Regulations that specify the requirements for solid fuel burning installations Suitable types of chimney include the following Masonry chimney built with clay or concrete liners or a chimney block system meeting Building Regulations These types of chimney should be installed in accordance with the Building Regulations and BS 6461 Part 1 Factory made insulated chimney complying with BS 4543 Part 2 often called Class 1 prefabricated metal chimney These types of chimney should be installed in accordance with the Building Regulations and BS 7566 Parts 1 to 4 17 INSTALLATION Due to the gradual introduction of European Chimney Standards chimneys will be specified according to their performance designation as defined in BS EN 1443 that covers the General Requirements for chimneys The minimum performance designation required for use with solid fuel burning stoves is T450 N2 S D3 The flue and chimney installation must be carefully checked by a competent person before fitting the stove to ensure it is suitable and will work safely If the chimney is old ie built of brick or stone wi
16. adjust by slackening off the lock nut and turning the adjusting nut on the damper plate When the cold setting distance has been correctly set re tighten the lock nut 19 INSTALLATION Ti MODELS ADDITIONAL INFORMATION FOR INSET STOVES Ti40B BUILDERS OPENING CHIMNEY BREAST Stratford Ti 40 fires are designed to be fitted into a rectangular recess not less than 400mm 15 3 4 deep not less than 400mm 15 3 4 wide and not less than 550mm 21 1 2 high the so called standard builder s opening The fireplace surround should be vertical and with a flat surface against which the unit can be sealed The height and width of the flat surface required will vary according to the model being installed Where the unit is to be fitted into an existing opening it will normally be necessary to cut a hole through the chimney breast so that a flue connector can be fitted between the appliance and the chimney flue Avoid damaging the lintel For boiler models it may be necessary to cut access holes through the side s or the chimney breast so that flow and return pipes can be connected to the appliance FLUE If using an insulated steel flue ensure that the manufacturer s directions are followed Take special note that the first 450mm 18 of the flue should be single skin cast iron or heavy duty steel flue When a flue lining is fitted to stainless steel or pumice chimney systems it should be supported independently to the applia
17. als instruction and the Final Installation Check List on p29 has been completed and signed by a suitably qualified engineer at the time of installation All Guarantee periods commence on the date of purchase and are non transferable Our Guarantee is offered as an addition to your statutory rights If you think your fire 1s not working correctly or in the event of a breakdown please call your local dealer When you contact them they will want to know 1 Your Name Address Post Code and Telephone Number 2 Serial Number 3 Clear and concise details of the fault CUSTOMER REGISTRATION See card enclosed To guarantee the very best in after sales service do not forget to complete and return your Customer Registration Card within 14 days a stamp is required Just complete the form and return it to us to 1 Benefit from our Guarantee 2 Register your appliance for a full year s Parts Guarantee Please contact us direct 01308 427234 if no Customer Registration Card is included Stratford Tf amp Ti Multifuel Boiler Stoves SERVICE RECORD Date of Visit Company Work Carried Out Signature Should you have any questions about your Stratford Stove that is not covered in this manual please contact your Aarrow retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits as they will complete the service
18. ce and increase the risk of chimney fire Note If you have sticky tar inside the appliance or chimney your wood is Green or too wet Recommended Reading Wood as Fuel available from the Forestry Commission Peat Can be used in turf or briquette form but again the moisture content must be low Paper paper will burn successfully Burn dry paper only or chimney damage will occur NEVER BURN PLASTICS OR WASTE IN YOUR STOVE Coal Household coal produces a large amount of ash and smoke If used the appliance and chimney will require frequent cleaning Therefore soft house coal is not recommended Recommended fuels are as follows The Hetas Ltd Three Tick appliance approval only covers the use of the following fuels in this appliance Phurnacite Phurnacite Plus Centurion Maxibrite Extracite Pureheat Blazebrite Taybrite Sunbrite Doubles Singles Anthracite Large Nuts and Welsh Dry Steam Coal Large Small Nuts Stratford Tf amp Ti Multifuel Boiler Stoves OPERATING INSTRUCTIONS Approval does not cover the use of other fuels either alone or mixed with the suitable fuels listed above nor does it cover instructions for the use of other fuels For latest details please refer to Hetas website www hetas co uk Do not use Homefire six sided and smaller sizes than Stovesse e g Beans Peas Grains Do not use petroleum based solid products such as Calco or Petrocoke To do so will invalidate the appl
19. ce some of the grate bars Periodic inspection of the bars is recommended and the removal of any nails or wire that may be present after burning wood All the grate bars in each appliance are identical and can easily be lifted out after removal of the fuel retainers Remove damaged grate bars and replace with casting of the same type fitting as per instruction above Check Identification letters on the casting when reordering FITTING BARS TO COMB THROAT PLATE INSPECTION The throat plate for all types of fires consists of a profiled steel plate with drop down facility for inspection purposes To drop the throat plate Fig 8 engage the operating tool behind the downstand tab marked throat plate and pull the plate frontward until its forward lugs drop into the cut away at the front of the side panel Check the upper surface for soot ash build up etc Reverse the procedure to return the throat plate to the working position Warning If the fire is operated with the throat plate in the down position the air wash will not operate effectively Stratford Tf amp Ti Multifuel Boiler Stoves ASSEMBLED GRATE ta 44 3 EELNE ood o 4d 4 ood Food Fig 8 16 FITTING THE FLUE OUTLET AND HOT PLATE The flue outlet spigot is found inside the appliance The hot plate blanking plate is supplied fitted to the top opening and is removed by turning clockwise as is the flue outlet Smear a very thin laye
20. ceptible to breakage or damage through careless handling dropping etc or through misuse of the appliance by over firing burning petroleum coke etc Nor can the guarantee extend to deterio ration of parts through fair wear and tear Firebox linings grate bars fuel retainer bars baffle gas keting materials and door glass are therefore not covered by the guarantee The guarantee is conditional upon the appliance being serviced and checked annually by a qualified heating engineer with documentation to be retained and to be produced in the event of a claim being made Claims are not valid where the installation does not conform to appropriate Building Regulations Parts will be repaired or replaced at the discretion of Arada Ltd The price of replacement shall be shared by the manufacturer and purchaser as fol lows e During the first year of purchase the manufacturer will pay 100 of the cost of parts only During the second year the manufacturer will pay two thirds of the cost and the purchaser one third 34 During the third year the manufacturer will pay one third of the cost and the purchaser two thirds USE OF SPARE PARTS OTHER THAN THOSE SUPPLIED BY Arada LTD WILL INVALIDATE THE APPLIANCE GUARANTEE If your appliance proves to be defective as a result of faulty materials or workmanship during guarantee we will repair or replace it FREE OF CHARGE as long as the fire has been installed according to the manu
21. d be fitted Do not use aerosol sprays or any other flame near the appliance under fire Do not fit an extractor fan in the same room as the appliance Fire cement is caustic hand and eye protection should always be worn prolonged contact with the skin should be avoided Arada Ltd will not be responsible for any consequential or incidental loss or injury however caused Before continuing any further with the installation of this appliance please read the following guide to manual handling Always obtain assistance when lifting the appliance When lifting always keep your back straight Bend your legs not your back Avoid twisting at the waist It is better to reposition your feet Avoid upper body top heavy bending Do not lean forwards or sideways when handling the fire Always grip with the palms of your hands Do not use fingertips for support Always keep the stove as close to the body as possible This will minimise the cantilever action Use gloves to provide additional grip THE PRINCIPLE OF THE FIRE Your Stratford stove is built to the highest standard of craftsmanship using the best materials and the most modern equipment available It is a highly efficient and sophisticated piece of machinery and when properly installed and operated it should pro vide a lifetime of heating satisfaction Stratford Tf amp Ti Multifuel Boiler Stoves INTRODUCTION Safety is the most important consideration
22. ected Stratford Tf amp Ti Multifuel Boiler Stoves ASH REMOVAL The ash pan should be emptied at least twice a day or when the level of ash reaches the top of the ash pan On no account should the ash be allowed to build up to touch the grate as this will greatly shorten its life DE ASHING It is necessary to maintain an ash layer on the upper surface of the grate bars in order to protect them so de ashing should cease as soon as the first red embers drop into the ash pan Further de ashing will cause heat build up under the grate which will considerably shorten its life This operation should be carried out with the doors closed to prevent dust escaping into the room Move up and down vigorously the riddling lever ash will fall into the ash pan beneath the grate When de ashing is complete re set grate to previous position Empty ash pan Note Do not force the riddling lever TO EMPTY THE ASH PAN Open the fire door open the ash door Fit the fork end of the operating tool into the ash pan and remove from the ash pit chamber WARNING The ash can be very hot Empty only to a metal container Even if the ash appears cold red hot pieces of ash may be concealed and could easily start a fire or cause an injury Replace the ash pan and close ash door Close the fire down CLINKER The formation of clinker suggests that the unit is being over fired Any clinker forming on the grate should be removed when cold
23. ed side air inlet beneath an access plate The damper plate at the rear side of the appliance regulates the amount of under draught entering depending on the setting of the thermostat control knob located at the bottom front on the left hand side of the unit and the temperature of the water transmitted through the sensor phial in the water jacket Stratford Tf and Ti with the ash door fully shut the settings range from 0 fully anti clockwise a shut off setting at which the damper will shut off the underdraught completely causing the fire to die down and in time go out to 8 fully clockwise the highest setting at which the appliance will burn fiercely and produce very high outputs For more information on the Ti inset model please see page 20 Note The area around the thermostat both inside at the back of the firebox and externally must be cleared of ash and other debris regularly See page 13 For setting instructions refer to Checking Thermostat on page 19 AARROW AIR WASH SYSTEM The air wash has an internal sliding plate with slots housed in a cover plate and is located above the fire door Sliding the control shaft to the right as far as it will go achieves the fully open position Sliding it to the left will shut off the air inlet slots The operating tool should be used to tap the control shaft to the desired setting Note Opening or part opening of the ash door is controlled by the interlock device loca
24. eft in the firebox increase the thermostat setting and vice versa In the morning Open the air control fully until embers begin to glow brightly and place pieces of fuel on the fire until it is well established WARNING When wood is burnt slowly in a closed appliance it produces moisture and tar which will create condensation and deposits in the chimney This effect can be minimised by burning hard for a short period about 20 minutes twice a day It is usually convenient to do this morning and night Note To avoid chimney problems your fire should not be burnt slowly for longer than 12 hours without a period of fast burning WARNING Properly installed with a suitable flue and chimney and operated and maintained this appliance will not emit fumes into the dwelling Occasional fumes from the de ashing and re fuelling may occur However persistent fume emission is potentially dangerous and must be investigated by a Hetas registered installer Stop using the appliance if you smell fumes or see smoke escaping If fume emission does persist the following immediate actions should be taken Open doors and windows to ventilate room Let the fire die or extinguish and safely dispose of fuel from the appliance Check for flue or chimney blockage and clean if required Seek expert advice from your HETAS registered installer Do not attempt to re light the fire until the cause of the fume emission has been identified and corr
25. em and the heat leak radiator particularly when the pump is running to ensure circulation is not reversed Be sure that the chimney is operating and that ALL smoke and fumes are vented to the atmosphere through the chimney terminal Check all joints and seals Clean the outside of the appliance to prevent any stains becoming burnt on Check the flue draught which should read 1 2mm or 0 1 0 2mbar The following details must be checked and completed in full by the installer at the time of installation Please answer all questions as fully as possible Arada Ltd can not be held responsible for chimney or installation Is the boiler cross flowed YES NO Are the pipes correctly sized YES NO What is the calculated output required to heat the system Is a heat leak fitted YES NO What is the return water temperature Is the pump thermostatically controlled by a pipe stat YES NO What is the height and distance of the hot water tank above the stove 29 CHECK LIST CHECKLIST Hearths Fireplaces Flues and chimneys This checklist is to ensure hearths fireplaces flues and chimneys are satisfactory and to show what you have done to comply with the requirements of The Building Regulations 2000 Approved Document J 2002 1 acad DE TT 4 Intended type of appliance State model and output 5 Ventilation provisions for the appliance State type a
26. f air through the appliance thus preventing moisture and condensation from building up inside the fire and chimney CHIMNEY SWEEPING Sweeping should be carried out with an appropriate sized bristle brush and rods to suit chimney size and type As with all appliances regular sweeping ofthe flue is essential to avoid the danger of blockage and the escape of poisonous fumes Access for cleaning should also be incorporated in the chimney e g soot door or access through register plate Any existing chimney should be swept prior to installation of the appliance and swept again a second time within one month of regular use after installation to establish frequency of sweeping required This should be done by a competent person such as a NACS chimney engineers who will provide a Certificate of Chimney Sweeping Sweep the whole flue way including the outlet at least twice per burning season It is important that the flue ways flue pipe and chimney be cleaned prior to lighting the fire after a prolonged shut down period 14 DOOR GLASS The door glass should remain clear during normal daytime burning However under certain conditions such as buming at a low rate with damp wood or overnight burning the glass may become somewhat blackened To remedy this operate the appliance at a fast rate Alternatively when the stove is cold open the door and clean the inside face of the glass with a damp cloth or with glass cleaner available from
27. fire stockists A piece of cloth moistened with vinegar and dipped in wood ash not coal ash will provide a good soft scourer to remove the soot without scratching the glass OUTER FINISH The outside finish of the appliance is a durable high temperature paint It is best cleaned by brushing down with a clean shoe brush Do not allow moisture to remain on the appliance whilst cold or surface rust may form The high temperature paint should not require attention for some time depending on use The hotter the fire burns the sooner repainting will be necessary Aerosol tins of paint are available for complete refurbishing Before repainting make sure that the fire is out and is cold Remove the door glass Lightly wire brush or rub with wire wool the body of the appliance to remove any loose paint powder Mask or remove items such as brass work Any adjacent brickwork mantelpiece hearth etc should be carefully masked for quite a distance around the appliance this precaution is to prevent discolouration of the surrounding brick work wallpaper etc Re spray in a well ventilated area avoid breathing the vapour Refer to safety instructions on paint cans When the paint is dry refit door glass and any other parts previously removed Leave the appliance for eight hours before re hghting Burn slowly for the first four hours then build up heat gradually to cure the paint Note Use only genuine Aarrow touch up
28. ford Tf amp Ti Multifuel Boiler Stoves 21 INSTALLATION TYPICAL METAL INSULATED CHIMNEY SYSTEM TO BE INSTALLED WITH THE CHIMNEY MANUFACTURERS INSTRUCTION BUILD REF BS7566 P11 4 E 600mm 24 minimum Rain cap Hi 50mm 2 gap to wall 2 4 metres 8 0 maximum Z Access for soot removal L Maxi mum Horizontal 150mm 6 PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES Access to chimney H for sweeping is minimum clearance for non insulated flue 1 5 x D to a non combustible surface material or 3 x D to combustible surface material 22 between support brackets or i Access for soot removal Non combustible register plate Minimum 1 5mm thick steel TOP FLUE OUTLET Stratford Tf amp Ti Boiler Multifuel Stoves INSTALLATION Central Heating and Domestic Hot Water System Using Four Boiler Tappings OPEN VENTS OLD WATER TANK FEED AND EXPANSIO ES A Im pun mi CENTRAL HEATING RETURN 22mm PIPE CIRCULATING PUMP DRAIN COCK AT LOWEST POINT Central Heating System Without Domestic Hot Water Using Four Boiler Tappings FEED AND EXPANSION TANK 22mm OPEN VENT a
29. ge installation 3to5 8 to 10 12 to 14 17 to 19 8 to 10 Height mm 596 645 709 709 595 Width mm 562 670 780 780 572 Depth to wall Depth mm 389 389 486 Dd orsus Height to centre of rear flue 447 503 555 555 N A Depth from back to centre of flue 138 138 172 172 106mm Flue diameter 127 5 127 5 152 6 152 6 127 5 Weight packed Kg 106 127 176 188 105 1kW 3420 BTU s Stratford Tf amp Ti Multifuel Boiler Stoves 25 4mm 1 inch OPERATING INSTRUCTIONS MULTIFUEL GRATE The Aarrow Multifuel grate comprises of a series of reciprocating cast iron bars seated on a pivoted comb These should come fitted in your stove if not please refer to page 16 for fitting and operation and also operating instructions on fuels for correct settings of the grate AIR INLET CONTROLS Stratford multifuel stoves have three air inlets The air wash system so called because its pre heated high speed air washes across the inner face of the door glass keeping it clear which provides over draught and The primary air inlet providing under draught to the base of the fire chamber through the gap between the body and the ash pit door Most importantly on the Stratford Boiler stoves is the thermostatic control system Please note partial opening of the ash door will over ride and negate the thermostatic control THERMOSTATIC CONTROL Stratford Tf Integral Boilers have a thermostatically controll
30. iance guarantee LIGHTING THE FIRE Prior to lighting the fire for the first time check with the installer that Installation and all building work is complete The chimney is sound and has been swept and is free from obstruction Adequate provision for combustion air has been made i e a permanent vent of at least 550mm per kW of rated output above 5 kW is fitted 1n the room in which the appliance is installed That Building Regulations and any local by laws have been followed during installation see installation instructions Throat plate 1s in place Ensure that the system is full of water and vented and precautions have been taken to prevent corrosion see installation Instructions That the chimney draw has been checked and is within specification With the chimney warm the draught should be between 1 2mm water gauge 0 1 0 2mbar WARNING An over drawing chimney can cause over firing resulting in damage to the appliance WARNING Do not light the fire if it is suspected that any part of the water system is frozen 11 OPERATING INSTRUCTIONS ENSURE THAT YOU HAVE READ UNDERSTOOD THESE INSTRUCTIONS BEFORE LIGHTING THE FIRE ALWAYS WEAR SUITABLE PROTECTIVE FIRE GLOVES WHEN REFUELLING YOUR STOVE SOLID FUEL BURNING Set the grate to coal position Ensure that the ash pan 1s in position and the fire doors are closed Set the air wash to one quarter open position Set the thermostat
31. iners grates firebox liners flue outlets hot plate throat plate etc can be removed Care should be taken to make sure that the hinges are not damaged during installation Stratford Tf amp Ti Multifuel Boiler Stoves INSTALLATION HEARTH The fire should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth should project at least 300mm 12 forward of the front of the appliance and 150mm 6 at the sides The surface of the hearth should be free of combustible materials In most buildings with solid concrete floors the requirement will be met by the floor itself but mark the perimeter of the hearth to ensure floor coverings are kept well away or use different levels to mark the hearth perimeter COMBUSTIBLE MATERIALS A gap of at least 450mm 18 should be allowed between the appliance and any combustible materials including furnishings Adjacent walls should be of suitable non combustible construction preferably brickwork In large fireplaces take care that any supporting beam is protected by a 13mm _ 0 5 sheet of Masterboard Supalux spaced 13mm 0 5 off the surface with strips of non combustible material not wood Make sure that there is a gap between an uninsulated flue system and any combustible material This gap must be at least 3 x the outside diameter of the flue pipe or 1 5 x the flue dia
32. is cold open the fire door so that it is at a right angle to the front Lift the fire door up off the hinges Drop one washer on the top and bottom hinge pin Refit the door and check to ensure door is free of the interlock If not remove and repeat fitting second washer FUEL RETAINER BARS Fuel retainer bars are supplied with the fires For wood burning 1 fuel retainer bar is used affording a better view of the fire Slide and lift the bar until it is clear of the guides at each side and remove through the fire door opening The bars are symmetrical and of even lengths making incorrect fitting impossible Note This operation should only be carried out when the appliance is unlit and cold Stratford Tf amp Ti Multifuel Boiler Stoves FUEL TYPES Wood Any type of wood is suitable provided it is well seasoned and has a moisture content below 20 This usually implies that the timber has been suitably stored to allow moisture to evaporate for at least nine months in the case of soft woods and at least eighteen months in the case of hard wood We recommend that for general burning wood should be split into logs of no more than 130mm 5 diameter Larger logs can be used for overnight burning WARNING wet wood must not be used as this will greatly contribute to the creation of tar and creosote which may in extreme cases run down the chimney in liquid form This will seriously damage both the chimney and the applian
33. ly THE FIRE DOOR MUST BE OPENED FIRST MULTI PURPOSE OPERATING TOOL Your Stratford stove comes with a multi purpose operating tool which is used to open the ashpit door riddling setting the multifuel grate position and for emptying the ash pan see fig 4 Fig 4 RIDDLING Use the operating tool for setting the grate in the coal burning position or the wood burning position This means that effective de ashing takes place and also allows the grate to be set in the coal burning or wood burning position as indicated on the right hand side of the appliance Stratford Tf amp Ti Multifuel Boiler Stoves OPERATING INSTRUCTIONS DOOR TRIM Stratford fire doors are fitted with a brushed steel finish trim as standard This clips on to the small lugs at the top and bottom of the aperture in the cast iron fire door as a spring fit When fitted the trim locks the glass retaining clips in position Fig 5 The fire door should be removed so that the above operations can be carried out on a workbench or similar Remove the door by GENTLY tapping the door upwards this will lift off of its hinges q Trim Fit Fig 5 FIRE DOOR GLASS If necessary the glass can be removed as follows Step 1 Remove the brushed steel finish trim by pressing on the curved edge at the top until the trim can be disengaged from the
34. meter to non combustible surfaces See the illustration on page 22 AIR FOR COMBUSTION There must always be a permanent means of providing air for combustion into the room in which the fire is installed A permanent vent with a total free area of at least 550mm for every kW rated output above 5kw should be connected directly to the outside air or to an adjacent room which itself has a permanent vent of the same size direct to the outside air The fitting of an extractor fan to either of these rooms is not recommended ACCESS TO THERMOSTAT A gap of 125mm around the body and 100mm to the rear of the stove is necessary to enable access to service amp repair the thermostatic control system 15 INSTALLATION MULTIFUEL GRATE All bars in the grate are identical but every other bar is turned through 180 degrees with the ends of the bars marked H sitting on the high sections of the comb and the ends marked L sitting on the low sections ASSEMBLING THE GRATE To assemble the grate fit bars to low sections of the comb first inserting end marked H into rear channel with groove on underside of bar located on upstand tab and then lowering end marked L onto the low section of the comb The upper bar is fitted in a similar manner but with the end marked L inserted in the rear channel and the end marked H seated on the high section of the comb GRATE BAR REPLACEMENT After extended use it may be necessary to repla
35. mneys 17 18 Airwash Inlet Controls 8 Integral Boilers 19 Interlock System 9 Checking the Thermostat amp Presetting to the Correct Damper Pressures 19 Multi Purpose Operating Tool 9 Additional Information for Inset Stoves 20 Riddling 9 Typical Installation for Boiler Models 21 24 Door Trim and Fire Door Glass 9 10 Boiler Tapping Positions 25 27 Door Adjustments 10 Water Connections 28 Fuel Retainer Bars 10 Hot Water Systems Check List 29 Fuel Types 11 Final Installation Check List 30 Lighting The Fire 11 PARTS LIST 31 33 Solid Fuel Burning 12 GUARANTEE 34 Overnight Burning 12 13 CUSTOMER REGISTRATION 34 Over Firing 13 SERVICE RECORD 35 Cleaning 13 FINAL FACTORY CHECK LIST 36 Accessories 13 Maintenance 14 Stratford Tf amp Ti Multifuel Boiler Stoves 3 WARNING TO ALL MULTIFUEL USERS PETROLEUM COKE SOME OF WHOSE BRAND NAMES ARE CALCO PETROCOKE OR WONDERCO MUST NOT BE BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www solidfuel co uk THE USE OF SPARE PARTS OTHER THAN THOSE SUPPLIED BY ARADA LTD WILL INVALIDATE THE APPLIANCE GUARANTEE Stratford Tf amp Ti Multifuel Boiler Stoves SAFETY A fireguard conforming to BS 8423 2002 should be used in the presence of children and old or infirm people If the appliance is used with the fire door open a spark guard conforming to BS 3248 shoul
36. nce ie with clips brackets flue lintels etc NOT simply resting on top of the appliance It should be possible to remove the fire for major maintenance work CHECKING THE THERMOSTAT Remove the thermostat knob by pulling off lift the side panel up and pull to the left to replace the opposite side repeat the above exercise The control knob which is inside the fire for despatch is fitted on to the shaft through the hole in the left hand casing It is however advisable to check the cold setting of the thermostat before installing and running the appliance This is best 20 seen from inside the appliance with the grate fuel retainer bars ash pan etc removed With the control set at minimum the damper should be just touching the side of the ash pit chamber all round the air inlet grill With the control set at maximum 8 and the damper plate parallel with the arm there should be a gap of approximately 23mm between the body and the edge of the damper plate furthest from the control shaft If the cold setting does require adjustment it will be necessary to remove the front trim to give access to the thermostat To do this first remove the control knob from the thermostat shaft then slacken the screws which fix the casing to the unit front a screwdriver can be inserted through the slots on the radius corner of the casing the back of the casing laps over the flange of the unit front Lift the casing and pull forward to remo
37. nce also need to be taken into account when selecting Design and calculations for individual heating systems should be carried out by a qualified heating engineer In many cases your supplier will be able to offer advice and assistance Direct Systems Stainless steel boilers either factory fitted or retro fitted as add in boilers enable connection to direct systems to be made without the need to change the cylinder or to fit an expansion tank This applies to domestic water supply only and should not be done when in an area with soft water If radiators are used then an indirect system must be utilised To connect the cylinder use 28mm copper pipes Ensure that the pipes rise continuously to the cylinder Ensure that the runs are not too long ie 20ft maximum each for flow and return Install the cylinder above the level of the fire and as close to it as possible the higher the cylinder the faster the circulation Ensure that no valves are present in the circulating pipes Indirect Systems The Domestic Hot Water Circuit In addition to providing hot water the primary circuit is essential in providing a heat leak to absorb excessive heat produced in the event of the circulation pump shutting down Heat is produced in varying quantities while the fire is alight and care must be taken to ensure that 28 effective circulation can occur around the primary circuit to carry heat away and thus stop boiling The output of a
38. nd area of permanently open vents 6 Chimney or flue construction State the type or make and whether new or existing internal flue size and equivalent height where calculated natural draught gas appliances only If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used If an existing chimney has been refurbished with a new liner type or make of liner fitted Details of flue outlet terminal and diagram reference Outlet Details Complies with f Number and angle of bends g Provision for cleaning and recommended frequency Hearth Form of construction New or existing Inspection and testing after completion Tests carried out by Tests and results Flue visual inspection sweeping coring ball smoke Appliance where included spillage I we the undersigned confirm that the above details are correct In my opinion these works comply with the relevant requirements in Part J of Schedule 1 to the Building regulations 30 Stratford Tf amp Ti Multifuel Boiler Stoves PARTS LIST Part Description Visual Aid Tf 30b Tf 50b Tf 70b Tf 90b Ti 40b not to scale Part No Part No Part No Part No Part No 1 Fuel Retainers ECCO mmm mm AFS152 AFS153 AFS153 AFS153 AFS152 2 Throat Plate AFS030A AFSO3I AFS034 AFS035 AFS032 3 Grate Bar Set G48 AFS001 AFSO01
39. ny radiator installed as a heat leak should not be less than 1096 of the rated output of the appliance The radiator should not be fitted with a control valve The cylinder must be of the indirect type with a minimum capacity of 110 litres conforming to BS 1566 part 1 Primary flow and return pipes should be 28mm diameter The cylinder should be installed at a higher level than the appliance and as close to it as possible the higher the cylinder the faster the circulation The flow and return pipes should not be longer than 20ft each Pipe runs should rise continually from the boiler to the cylinder A radiator of approximately 25 sq ft should be connected into the primary circuit if installed in the bathroom it provides a means of drying towels in the summer Safety Vent Circuit This circuit consists of a cold feed pipe expansion pipe and expansion tank The possibility that water may boil can never be completely ruled out and it is therefore vital to ensure that cold water can be supplied to the boiler and steam vented from it at all times The expansion tank should have a capacity of at least 7 of the system s water capacity The cold water feed pipe should be at least 22mm diameter There must not be any shut off valves in the circuit Pipes should be run to avoid air locks A safety relief valve should be fitted to the expansion pipe close to the boiler It is often possible and is good practice to utilise the p
40. r of fire cement on the faces of the flue outlet and the blanking plate Fit the outlet to the appliance in the desired position Lock into place by rotating anti clockwise and tighten by tapping with a block of wood and mallet from the inside of the appliance Similarly fit the blanking plate to the unused opening Clean off any surplus fire cement Place appliance on the hearth and make sure that it is level and does not rock Connect the chimney ensuring all joints are sealed with fire cement NOTE THE FLUE PIPE MUST BE FITTED INSIDE THE OUTLET SPIGOT FAILURE TO DO SO COULD RESULT IN THE SPILLAGE OF CONDENSATION ECT RUNNING DOWN THE FLUE Fig 13 Flue and Spigot Fitting Stratford Tf amp Ti Multifuel Boiler Stoves INSTALLATION FLUES AND CHIMNEYS Please remember that chimney draught is dependent on four main factors Flue gas temperature Flue height Flue size Flue terminal The stove must be connected to a suitable and efficient flue that provides a good updraught to safely take the products of combustion fumes from the stove outlet to the outside air To ensure a good updraught it is important that the flue gases are kept warm and that the flue size suits the stove The termination of the outlet at the top of the flue also needs to comply with the Building Regulations The minimum effective height of the flue must be at least 4 5 metres from the top of the stove to the top of the flue outlet
41. rimary flow and return as part of the safety circuit The ball valve should have a copper ball The overflow pipe from the expansion tank should be 28mm diameter copper Pipes in unheated spaces must be lagged Stratford Tf amp Ti Multifuel Boiler Stoves Temperature and Pressure Relief Valve With solid fuel appliances it is not practicable to provide a sufficiently rapid reaction for shutting down fuel in the event of a sudden rise in water temperature and a temperature relief valve or preferably a combined temperature and pressure relief valve should be installed to operate in the event of high water temperatures occurring See diagram below PIPE VENT COLD WATER HOT WATER Lp STORAGE VESSEL y HOT WATER EE Y SELF SETTING DRAIN COCK A TEMPERATURE RELIEF VALVE OR COMBINED TEMPERATURE AND PRESSURE RELIEF VALVE TUNDISH AND DISCHARGE PIPE HOT WATER SYSTEMS Before handing over the installation to the customer it is strongly recommended that the appliance is lit and the functioning of the chimney hot water and heating system is checked A checklist Pre lighting Checks appears in the Operating Instructions but in addition to this the installer should Operate the heating system and set the pump head Balance the radiators Re vent and ensure no air locks Stratford Tf amp Ti Multifuel Boiler Stoves HOT WATER SYSTEMS INSTALLATION Check the circulation round the primary syst
42. ted in the front of the unit refer to INTERLOCK section on page 9 Even when all the slots are completely shut a bleed of secondary air will be maintained ensuring that inflammable gases are burnt off DISASSEMBLE AIR WASH The Stratford air wash may be disassembled for cleaning or adjustment To achieve this the following procedure should be followed This should only be carried out when the fire is cold and unlit Support Air wash cover with one hand Move cover up by smartly tapping the bottom with a hammer Fig 3 Remove assembly from appliance Clean and or adjust Refit using reverse procedure Stratford Tf amp Ti Multifuel Boiler Stoves INTERLOCK SYSTEM Stratford Tf and Ti Multifuel Boiler Stoves are fitted with an interlock system A situation where the fire door is closed and the ash door is open may lead to serious overfiring which could damage the appliance Correct use of the doors and interlock system will ensure that this does not happen Operation is as follows A pivoted lug prevents closure of the fire door unless the ash door has been shut first When the fire door is shut the ash door knob can be turned anti clockwise by up to 95 degrees creating a variable gap between the top of the ash door and the body through which primary combustion air can enter the appliance Note In order to turn the ash door knob sufficiently for the catch to release and permit the ash door to be opened ful
43. thout a liner or being opened up for reuse additional checks and smoke testing as described in Appendix E of the Approved Document J 2002 Edition should also be carried out to ensure the flue and chimney are in good operating condition Unless the existing flue is in good condition with suitable access for collection and removal of debris If the flue size is more than 225mm 9 inches diameter or 200 x 200mm square a suitable lining of 150mm 6 inches diameter should be fitted or if the flue length is over 5 5 metres one size larger than the appliance outlet should be fitted This should be a double skin stainless steel flexible flue liner that is independently certified for use with solid fuel Details of suitable linings for use with solid fuel are given in the Official HETAS guide that can be viewed on their website at www hetas co uk It is also important that suitable flue pipe complying with the Building Regulations is used to connect the stove to the flue in the chimney and that suitable access is provided into the flue for regular inspection and sweeping of the flueways The installer should comply with the Building Regulation requirements in respect of providing a Notice Plate giving details on the chimney flue lining hearth and fireplace installation Approved Document J of the Building Regulations for England and Wales is available from The Stationery Bookshops and can also be viewed at the ODPM website at www safety odpm go
44. v uk bregs brads htm Details of the relevant Building Regulations and BS British Standards are given in the General Precautions section page 15 of these instructions 18 Chimneys should be as straight as possible Horizontal runs should be avoided except where the rear outlet of the appliance is used in which case the horizontal section should not exceed 150mm 6 in length If the fire appears to be working hard but produces very little output to the room it is likely that excessive draw is present in the chimney and that heat is being sucked out of the appliance and up the chimney If this is the case we recommend the fitting of a draught stabiliser in preference to a flue damper in the interest of safety and efficiency We do not recommend the use of a damper when burning solid fuel FOR ALL APPLIANCES Access for cleaning the flue should be incorporated in the system other than through the appliance e g a soot door or access through register plate Purpose made soot doors and inspection lengths are available from manufacturers of all systems Ensure that the whole length of the flue can be reached from the soot door Note if the appliance is fitted with a draught stabiliser or if one is fitted to the flue pipe or chimney in the same room as the appliance then the permanent air entry opening or openings should be increased by 300mm for each kW of rated output For advice on flues and chimneys contact NAC
45. ve Adjust the setting by slackening off the lock nut Replace the casing on the unit front and refit the control knob on to the thermostat shaft INSTALLATION Fill the space around the appliance level with the top unit with Vermiculite cement 6 parts Vermiculite granules to 1 part Portland cement The flue socket in the appliance is designed to receive 5 or 6 nominal cast iron or heavy duty steel pipe connector which should be caulked with asbestos rope and fire cement The length of the connector pipe will be dependent on the distance between the top of the appliance and the bottom of the chimney but should be at least 300mm 12 Fill the remaining space around the connector with the Vermiculite cement to a level where the pipe is effectively sealed in the chimney flue ensuring that the flue gases can only be discharged into the flue way Reinstate brickwork to chimney breast and make good Remember to make provision for access to boiler connections for routine observation maintenance Replace parts previously removed and check unit thoroughly Stratford Tf amp Ti Boiler Multifuel Stoves INSTALLATION Minimum 6 dia el ase 7 8 Recommended Maximum 150mm 6 Horizontal flue Soot door Fire redardent packing Minimum 150mm 6 ilius Brick up aperture H Fill void REAR FLUE OUTLET Strat
46. when installing your fire If not properly installed and operated a house fire may result Installation must comply with the Building Regulations and conform to all relevant fire safety standards Arada produce a variety of appliances ranging from units which are traditional in style to stoves which are modern in appearance all bristling with High Tech features Model types include simple room heaters convectors integral boiler models and inset units Your Stratford stove is constructed from either sin gle or twin wall steel strengthened where necessary Cast iron is used where appropriate for decorative features All fire doors are fitted with special high temperature ceramic glass panels through which the fire can be viewed Multifuel stoves are fitted with a cast iron grate to give full multifuel facility and positive de ashing All models except integral boiler models are lined with firebricks or heat reflective panels which ensure complete combustion and provide a good heat store to even out fluctuations in burning An internal throat plate produces turbulence to encourage secondary combustion and directs the flue gas around the whole upper firebox before allowing it to escape up the chimney On multifuel appliances the primary air for burning enters the ash pit chamber beneath the grate controlled by the air inlet mechanism Stratford stoves are also fitted with an air wash so called because it provides a curtain