Home

Bantam BC8HP Specifications

image

Contents

1. Discharging Lithium battery The value of discharge current on the left side of screen may not exceed 1C for a maximum safety The final voltage at the end of discharge is on the m xm right according to the cell count and type of battery DESING ai amn For LiPo it is 3 0V cell START To start to discharge press ENTER START button for more than 3 seconds Discharge current 0 1 7 0A Dispiay number elapsed battery discharged of i voltage capacity cells time discharge current Discharge current limit by circuit power For the voltage of battery is more than 3 6V the actual amount of discharge current may be limited automatically not to exceed the charger s maximum rated discharging power of 25 watts Voltage monitoring during the discharge The charger monitors the voltage of individual cells during discharge mode of Lithium battery pack For this feature the individual plug of the battery pack should be connected to the individual port of the charger If the voltage of any one or more cells varies abnormally during discharge BC8HP terminates the process forcibly with the error message If this happens the battery pack contains a bad cell or bad connection of the cable or plug You can easily know which one cell is not normal by pressing INC button at time of showing the error message The processor found that the voltage of one of the cell in the Lithium battery pack is too low Display
2. In this case the 4th cell is bad If there happens the connection break of the cable or plug the voltage value may show zero sg NiMH NiCd battery program These programs are for charging or discharging NiMH Nickel Metal Hydride or NiCd Nickel Cadmium battery commonly used for R C model applications Charging NiCd NiMH battery Dispiay DEC INC TYPE ENTER STOP START charged battery elapsed capacity type time battery voltage charge current This program simply charges the battery using the current you set You can select charge current mode in A automatic or M manual In Auto mode you need to set the upper limit of charge current to avoid from higher feeding current that may damage the battery Because some batteries of low impedance and small capacity can lead to the higher charge current by the processor at automatic charge mode But in Man mode it will charge the battery with the charge current you set at the display Press ENTER START button to make M or A blinking Change the current mode to M or A using INC or DEC button Press ENTER START button to alter the charge current Change the current value using INC or DEC button Press ENTER START button for more than 3 seconds to start charging Discharging NiCd NiMH battery DEC INC DEC INC TYPE ENTER
3. The voltage of input power drops below the limit The voltage of Lithium battery pack was selected incorrectly Verify the voltage of battery pack carefully There happens the malfunction at the charger circuit by any reason The charger should be repaired at our factory The processor detects the voltage is lower than you set at Lithium program Please check the cell count of the battery The processor detects the voltage is higher than you set at Lithium program Please check the cell count of the battery The voltage of one of the cell in the Lithium battery pack is too low Please check the voltage of the cell one by one The voltage of one of the cell in the Lithium battery pack is too high Please check the voltage of the cell one by one There are bad connection at the individual connector Please check the connector and cables carefully The internal temperature of the unit goes too high Cool down the unit The processor can not continue to control the feeding current by any reason The unit needs to be repaired 18 Glossary of terms Amps A The unit of measure for charge or discharge electric current The program of the charger will show most of the current in amps A at its LCD screen Milli amps mA The electric current being amps A multiplied by 1000 and noted as So 2 0A is the same as 2000mA 2 0x1000 Or to convert mA to amps divide the mA number by 1000 So 200mA is the same as 0 2A If
4. Always follow the instruction which is supplied by the manufacturer of battery Charging Pb battery Set up the charge current on the left and the nominal voltage of the battery on the right The charge current ranges from 0 1 to 12 0A and the voltage should be matched with the battery being charged ENTER the charge process by pressing DEE uw ENTER START button for more than seconds DEC INC DEC INC The screen displays the state of charging process To stop charging forcibly press TYPE STOP button once Display battery elapsed battery charged type time voltage capacity charge current Discharging Pb battery Set discharge current on the left and final voltage on 2 the right The discharge current ranges from 0 1 to ERS 70A INC DEC INC TYPE STOP em START The screen displays the current state of discharge To stop discharging press TYPE STOP button once The audible sound indicates you at the end of battery discharged process battery elapsed voltage capacity time type discharge current 16 Various information during the process You can inquire various information on LCD screen during charging or discharging process When you press DEC button the charger shows the establishment of user settings And also you can monitor the voltage of individual cell by pressing INC button when the individual connectio
5. a current value is below 1 0A the LCD screen of the charger will still show the current in amps not milli amps For example a current of 600mA will be displayed as 0 6A and a current of 100mA will actually be shown as 0 1A Capacity milli amp hours mAh and amp hours Ah Charge energy stored by a battery is called capacity which is defined as how much current a battery can supply constantly over one hour of time Most hobby batteries are rated for capacity in mAh or milliamp hours A 650mAh battery can deliver 650mA of current for one hour 650mAxihr 650mAh The batteries of very large capacity such as lead acid Pb batteries are usually rated in or amp hours A 12V 60Ah car battery can deliver 60 amps of current for one hour 60Ax1hr 60Ah Nominal voltage V The nominal voltage of the battery pack can be determined as follows NiCd or NiMH multiply the total number of cells in the pack by 1 2 A 8 cell pack will have a nominal voltage of 9 6 volts 8x1 2 LiPo multiply the total number of cells in the pack by 3 7 A 3 cell LiPo wired in series will have a nominal voltage of 11 1 volts 3x3 7 Lilo multiply the total number of cells in the pack by 3 6 A 2 cell Lilo wired in series will have a nominal voltage of 7 2 volts 2x3 6 LiFe multiply the total number of cells in the pack by 3 3 A 4 cell Lilo wired in series will have a nominal voltage of 13 2 volts 4x3 3 If the nominal voltage of the batte
6. already fully charged or just slightly discharged Non rechargeable batteries Explosion hazard Batteries that require a different charge technique from NiCd NiMH Lilo LiPo LiFe or Pb Faulty or damaged battery Battery fitted with an integral charge circuit or a protection circuit Batteries installed in a device or which are electrically linked to other components Batteries that are not expressly stated by the manufacturer to be suitable for the currents the charger delivers during the charge process To avoid short circuits between the charge lead always connect the charge cable to the unit first and only then to the battery to be charged or discharged Reverse the sequence when disconnecting Do not connect more than one battery pack to the charge lead at any one time Please bear in mind of checking the following point before charge operation Did you select the appropriate program which are suitable for the type of battery Did you set up adequate current for charging or discharging Lithium battery pack can be composed with parallel and series circuits mixed You have to check the composition of the battery pack carefully before charging Are all connections firm and safe or is there an intermittent contact at any point in the circuit Q Input power source requirement When the charger runs on its maximum power the input power should be enough to run the charger safely and effectively If the input v
7. buttons Busse ON to your action The beep or melody sounded at various times during operation to alert different E mode changes These audible sounds can be on or oro DEC ING off Key Beep ON Input power low This program monitors the voltage of input battery Cut Off 10 0V If the voltage drops below the value you set the operation forcibly terminated to protect the input Z veo f nc battery Back light You can adjust the brightness of LCD screen at the 100 charger DEC INC e Program Memory BC8HP can store the setting data of every program for your convenience This feature can store up to 10 battery data for each type of batteries by number that represents the individual parameters They can be called back for the process of charging or discharging without setting up the program again PROGRAM MEMORY LP aaa MEMORY m LiPo 0 LiPo aaa ew DEC INC Select the data number using INC or DEC button Each data had been stored by their last TEE aS CHARGE setting Then press START ENTER button to 12 0A 11 TEE aS enter the program Or press TYPE STOP button to go for other program Battery connection to charger All batteries are charged should be connected through the main charge leads go to output port of charger The balance connection which goes to balance port is only required when running Balance p
8. individual voltage of each cell in the Lithium battery pack When using the optional thermal probe part no EAC110 When the software which can be downloaded at our web page is installed at PC using with USB cable kit e Exterior of the unit ec STATIOM Cooling fan Balance Charger Discharger Charging lead 1727 calls NIMH NICA 2V 36V Leadracid Pb connector Charge rate 0 1 to 12 Discharge rate 0 1 to 4mm banana female Input power cable um DC11 18V LiPo 0 BALANCE LCD screen ES 100A 22 2 65 16chr x 2lines Temperature A Individual cell sensor port connector port USB port lenior 000000000000004000074000 s TYPE STOP Dec Inc ENTER START To select main program To select sub program resume or start the operation To stop the operation To alter the value e Warnings and safety notes Never leave the charge unsupervised when it is connected to its power supply If any malfunction is observed immediately terminate the process and refer to the operation manual Keep away the unit from dust damp rain heat direct sunshine and vibration Do not drop it The circuit of the unit is designed to be powered by 11 to 18V DC only This charger and the battery to charge or discharge should be set up on a head resistant non inflammable and non conductive surface Never place them on a car seat carpet or similar Keep all the inflammab
9. ONFIRM ENTER cells found by the charger and S is the number __ er of cells selected by you at the previous screen If both numbers are identical you can start charging by press ENTER START button If not press TYPE STOP button to go back to ENTER previous screen Then carefully check the number of cells of the battery pack to charge again The screen shows the present situation during charge process To stop charging forcibly press TYPE STOP button once number charging Battery res i oltage capaci of charge varag ll current 10 Charging Lithium battery at balance mode This is for balancing the voltages of Lithium batteries of the battery pack to be charged To do this the battery pack being charged should have the individual cell connector and connect it to the individual port at the right side of charger with a suitable connection cable that fits with your battery pack And you should connect the battery output plug to the output of charger either In this mode the charger will monitor the voltages of each cell of the battery pack and controls the charging current that is feeding to each cell to equalize the voltage LiPo O BALANCE 2 0A 11 1V 3 c DEC INC DEC INC TYPE STOP ENTER START R 3SER S 3SER CONFIRM ENTER 2 Display 1138 1 2 12 59 BAL 022 43 00682 voltage charged capacity number charging o
10. Operating Manual STATION s Microprocessor controlled high performance rapid charger discharger with integrated balancer 280watts of charging power USB PC link and firmware upgrade Temperature sensor Charge current up to 12A discharge current up to 7A 1 to 8 series of Lilo LiPo LiFe 1 to 27 cells of NiCd NiMH 2 to 36V of Lead acid Pb ec sr ATIO sesue Balance Charger Discharger 1 8 series Lilo LiPo LiFe with balancer 1 27 cells NiMH NiCd 2V 36V Lead acid Pb Charge rate 0 1 to 12A Discharge rate 0 1 to 7A o c v 9 LiPo 0 BALANCE 10 0A 22 2V 6S e e ce BANTAM 2000000000000000000000000000000 jade in Korea INPUT DC11 18V 4 Balance 700007770000000004 We reserve the right to commit modifications Copyright reserved Thank you for purchasing the e STATION BC8HP charger You get a rapid charger discharger with integrated balancing circuit which is computerised with a high performance microprocessor and specialised operating software Please read this operating manual completely and attentively as it contains a wide variety of specific programming and safety information You need to keep this manual in a safe place and be sure to pass it on to the new owner if you ever dispose of BC8HP Special features Operating software Every operating program in the unit is controlled with mutual links and communications to prevent every possible error so
11. STOP START Display battery discharged battery elapsed i voltage capacity time type discharge current Set discharge current on the left and final voltage on the right The discharge current ranges from 0 1 to 7 0A and the final voltage ranges from 0 1 to 30 0V To protect the battery from damage by deep discharge set the final cut off voltage at safe range The minimum cut off voltage is 0 85V cell for NiCd and 1 0V cell for NiMH If you set the voltage as AUTO the charger will determine the final voltage depending on the battery condition 14 Display c DEC INC DEC INC TYPE ENTER STOP START Display battery discharged voltage or charged capacity battery elapsed time type discharge or charge current Display Oisplay DEC INC DEC INC TYPE ENTER STOP START Display battery elapsed type time battery charged voltage capacity charge current Cycle C gt D D gt C mode NiMH NiCd battery Set the sequence on the left and the number of cycle on the right You can use this function for balancing refreshing and break in the battery To avoid rising temperature of the battery there will a brief cool off period that already fixed at User program setup after each charge and discharge process The cycle program uses the charge current discharge current and discharge cut off voltage which are set on previous programs ch
12. al charging but the process time will be reduced You can set up the charging current and the voltage of the battery pack being charged As you press ENTER START button the voltage confirmation will be displayed And then if you TYPE STOP ENTER ENTER START button again to start charging START DEC INC i DEC INC confirm the voltage and current press This shows the present state of FAST charging To stop charging arbitrary press Displ y TYPE STOP button once number elapsed charge supplied Current time current capacity voltage of cellis battery STORAGE control Lithium battery This is for charging or discharging Lithium battery not to be used for the time being The program will determine to charge or discharge the battery to the certain voltage depending on the voltage of the battery at its initial stage They are different from the type of the battery 3 7V for Lilo 3 8V for LiPo and 3 3V for LiFe per cell If the voltage of battery at its initial stage is over the voltage level to storage the program will start to discharge first You can set up the current and the voltage of the battery pack to be charged The current will be used for charge or discharge the battery to reach the storage level of voltage Disp ay DEC INC DEC INC IYPE 1 ENTER STOP START Displey rumoer elapsed charge supplied Current time or capacity voltage of cells discharge battery current 12
13. arge and discharge The cycling number ranges from 1 to 5 At the end of the process you can see charged or discharged electric capacities of the battery at each cyclic process By pressing INC or DEC button the screen shows the charged or discharged capacity of each cycle in order Reflex charge NiMH NiCd battery The battery will be charged using the pulsed current which is very brief and high rate discharge pulses This will help to prevent from undesired side effect like memory effect When you select this mode you need to set the partial capacity which will be charged with reflex mode The charger will work with Reflex mode only until the capacity has been charged then the charger will work at Normal mode Set the charge current on the left and the partial capacity on the right The partial capacity should be less than the total capacity of battery Press and hold ENTER START button for more than 3 seconds to start the process 15 Pb acid battery program This is programmed for charging and discharging Pb lead acid battery of nominal voltage from 2 to 36V Pb batteries are totally different from NiCd or NiMH batteries They can only deliver relatively lower current compare to their capacity and similar restrictions definitely apply to charge So the optimal charge current will be 1 10 of the capacity Pb batteries must not be charged rapidly
14. ating voltage range 11 0 18 0 Volt Circuit power max 280Watts Charging max 30 Watts discharging Charge current range 0 1 12 0A Discharge current range 0 1 7 0A Current drain for balancing Lipo 200mAh cell NiCd NiMH battery cell count 1 27 cells Lithium battery cell count 1 8 Series Pb battery voltage 2 to 36V Weight 880 g Dimensions 160 X 120 X 40 mm Warranty and service We warrant this product for a period of one year 12 months from the date of purchase The guarantee applies only to such material or operational defects which are present at the time of purchasing the product During that period we will repair or replace without service charge any product deemed defective due to those causes You will be required to present proof of purchase invoice or receipt This warranty does not cover the damage due to wear overloading incompetent handling or using of incorrect accessories BANTAM Inc 623 Unitech Ville 1141 2 Electrical equipment marked with BAEKSEOKDONG ILSANDONGGU the cancelled waste bin symbol GOYANGSI KYUNGGIDO must not be discarded in the KOREA 410 722 standard household waste instead it should Phone 82 31 904 3939 Fax 82 31 901 6439 be taken to a suitable specialist disposal E mail bantamtek bantamtek com Web www bantamtek com Date of purchase delivery system Dealer BANTAM
15. can be on or off If it is on set the maximum temperature at which the charger should allow battery to reach during charge Once a battery reaches this temperature during operation the process will be terminated to protect the battery The battery which is on the cyclic process of charge and discharge can often become warm after charge or discharge period The program can insert a time delay to occur after each charge and discharge process to allow the battery adequate time to cool down before being subjected to the next process The value ranges from 1 to 60 minutes You can set the trickle charge mode on or off If it is on the charger will automatically supply the trickle charge current to achieve the full charge without overheating the battery after fast charge has been terminated When you start a charge process the integral safety timer automatically starts running at the same time This is programmed to prevent overcharge the battery if it proves to be faulty or if the termination circuit cannot detect the battery full The value for the safety timer should be generous enough to allow a full charge of the battery This program sets the maximum charge capacity that will be supplied to the battery during charge If the delta peak voltage is not detected nor the safety timer expired by any reason this feature will automatically stop the process at the selected capacity value 8 The beep sounds at every time pressing the
16. f e cells charge current The value on the left side of second line sets a charge current and the value on the right side of second line sets the voltage of the battery pack After setting the current and voltage press ENTER START button for more than 3 seconds to start the process Charge current 0 1 12 0A Voltage 2 8 series This shows the number of cells you set up and the processor detects shows the number of cells found by the charger and S is the number of cells selected by you at the previous screen If both numbers are identical you can start charging by press ENTER START button If not press TYPE STOP button to go back to previous screen Then carefully check the number of cells of the battery pack again The screen shows the present situation during charge process To stop charging press TYPE STOP button once yD 0 f it o o o o Individual bal port 1 tet Individual bal port 11 FAST charging Lithium battery The charging current is getting smaller as the process goes to the near end term of Lithium battery charging To finish charging process earlier this program eliminate certain term of CV process Actually the charging current will goes to 1 5 from the initial value to end the process while the normal charging goes to 1 10 at end of CV term The charging capacity may be a bit smaller than norm
17. isable The charger would not detect Delta peak voltage for termination To terminate charging process the charger will check the parameters set up at other safety parameters like max capacity safety timer or safety temperature If any one has been reached at its limit the charging process will be terminated for NiMH only Delicate The charger will detect a very small variation at delta peak voltage Some NiMH batteries which shows small voltage drop at peak need to be use this option n DEC INC Z DEC INC NiMH NiCd D Peak Delay time 15min DEC INC orc fc Temp Cut Off ON 80C NES DEC INC DEC INC DEC INC Waste time CHG DCHG 5min t DEC INC DEC INC DEC INC NiMH NiCd Pb Trickle 100mA DEC DEC INC Safety timer ON 120min 4 DEC INC DEC INC DEC INC Capacity Cut Off ON 5000mAh BEES DEC INC DEC INC DEC INC Default If you do not know much about this function or for ordinary batteries select this mode 12mV cell for NiCd or 8mV cell for NiMH will be used This restrains the delta peak voltage detection until the time has reached This prevents a premature cut off from the battery of high internal resistance The default value is one minute 1 15 minutes An optional feature using temperature probe contacting the surface of battery the temperature cut off
18. it introduces the maximum safety such as input voltage warning reverse polarity protection and Lithium cell count input error warning The entire firmware can be upgraded via USB from internet download at our web page when there needs to be changed High power and high performance circuit BC8HP employs the circuit that has maximum output power of 280Watts As a result it can charge or discharge up to 27 cells of NiCd NiMH and 8 series of Lithium batteries with maximum current of 12A Furthermore the cooling system is so efficient that can hold such a power without any trouble running the circuit or the operating program Accept various types of Lithium battery BC8HP can accept three types of Lithium batteries Lilo LiPo and LiFe They have different characteristics by their chemistry You can select any one of them that you are going to process before the job For their specifications refer Warnings and safety notes section Lithium battery Fast and Storage mode You can charge Lithium battery for special purposes Fast charge reduces the charging time of Lithium battery and Storage mode controls the final voltage of the battery to be suit for long time storage Maximum safety Delta peak sensitivity The automatic charge termination program works on the principle of the Delta peak voltage detection NiCd NiMH Auto charge current limit When charging NiCd or NiMH at AUTO current mode you can set the upper limit
19. le volatile materials well away from operating area Be careful to touch the charger body when charging or discharging at charger s maximum power It may be very hot and can cause a physical damage on your finger or body Be sure to understand the information of the battery to be charged or discharged accurately If the program is set up incorrectly the battery can severely be damaged Especially Lithium battery can cause a fire or an explosion by over charging NiCd NiMH voltage level 1 2V cell allowable fast charge current 1C 2C discharge voltage cut off level 0 85V cell NiCd 1 0V cell NiMH Lilo voltage level 3 6V cell max charge voltage 4 1V cell allowable fast charge current 1C or less min discharge voltage cut off level 2 5V cell or higher LiPo voltage level 3 7V cell max charge voltage 4 2V cell allowable fast charge current 1C or less discharge voltage cut off level 3 0V cell or higher LiFe voltage level 3 3V cell max charge voltage 3 6V cell allowable fast charge current 4C or less e g A123M1 discharge voltage cut off level 2 0V cell or higher Pb voltage level 2 0V cell Lead acid max charge voltage 2 46V cell allowable fast charge current 0 4C or less discharge voltage cut off level 1 75V cell or higher Do not attempt to charge or discharge the following types of battery Battery pack which consists of different types of cell including different manufacturers Battery which is
20. n cable is linked to the Lithium battery being processed Display Display Display Display Display Display Display Display Display The final voltage will be reached at the end of process The internal temperature of the charger and the temperature of battery being charged The external temperature only will be displayed when using the thermal probe The present voltage of input DC power Using the individual connection cable to the battery you can check the individual voltages of each cell in the battery pack When connect the cable to the port on the right side of the charger the program shows them for maximum 8 cells in sequence To utilise this feature the battery pack must have output connector that linked to each cells sd Warning error messages BC8HP incorporates a various functions of protective and monitoring the system to verify functions and the state of its electronics In any case of occurring error the screen displays the cause of error that is self explanatory with audible sound Display Displa Display Display Display The output is connected to a battery with incorrect polarity This will be displayed in case of detecting an interruption of the connection between battery and output or voluntarily disconnecting the charge lead during the operation of charge or discharge on output There was a short circuit at OUTPUT Please check the charging leads
21. of charge current to avoid from feeding high current to the battery This is very useful when charging the low impedance and small capacity NiMH battery in AUTO mode Capacity limit The charging capacity always calculated by multiple of the charging current and time If the charging capacity exceeds the limit the process will be terminated automatically when you set the maximum value E Temperature limit The temperature of the battery on charging will rise by its internal chemical reaction If you set the limit of temperature the process will be expired forcibly when the limit has been reached Processing time limit You can also restrain the maximum processing time to prevent from any possible defect Input power monitor To protect the car battery using as input power from being damaged its voltage always being monitored If it drops below the lower limit the process will be ended automatically Data store load For users convenience it can store maximum 10 data of different batteries You can establish the data contains program setting of the battery to charge or discharge These data can be called back at any time you need and the process can be executed without program setting PC based analysis using USB communication For technical expert BC8HP offers PC based program can analysis the characteristic of the battery by USB port It shows a graph of voltage current capacity and temperature curves It also shows the
22. oltage is lower than 11 0V the charger may be shut down or limited by its circuit power To utilize the charger s maximum power the input power source should have good power above 15V and 35A If the input voltage is lower than 12V the charger s charging power can be limited by 200W e Program flow chart ENTER a mm E lt gt aditus m ueste ueste CHARGE IN BALANCE FAST CHG TYPE STOP INC ENTER LiXX LiXX START lt gt LiFe battery DISCHARGE bee STORAGE TYPE STOP ENTER START Lilo battery v TYPE STOP mm Xx 22 22 mm EX i TYPE STOP ENTER NiXX NiCd START Reflex char ge i gt Sio rey patt a nm a CHARGE mmm HEE Power gt eee ES Low Ed off Buzzer NiMH NiCd Pb gt Sume Safety Tier Timer STOP Trickle charge d Cut off INC lt DEC INC CHG gt DCHG D Peak Waste Time E Temp Cutet LE time E SET START NiMH D Er E AE CHK Time Er C Initial parameters setup User Program Setup BC8HP will be operated with the default value of the essential user settings when it is connected to 12V DC input power source for the first time The screen displays the following information in sequence and the user can change the value of parameter on each screen When you are willing to alter the parameter value in the program pre
23. rogram e Lithium battery Lilo LiPo LiFe program These programs are only suitable for charging and discharging Lithium batteries with a nominal voltage of 3 3V LiFe 3 6V Lilo and 3 7V LiPo per cell The final voltage of charge process is very important it should be precisely matched with the charged voltage of the battery They are 4 2V for LiPo 4 1V for Lilo and 3 6V for LiFe The charge current and nominal voltage as for cell count set on the charge program must always be correct for the battery to be charged When you are willing to alter the parameter value in the program press ENTER START button to make it blinking Then change the value using INC or DEC button The value will be stored by pressing ENTER START button once Charging Lithium battery n The left side of the first line shows the type of LiPe 0 CHARGE CHARGE battery and data number The value on the left 10 11 1 s side of second line sets a charge current and the value on the right side sets the voltage of the battery pack In AUTO the charger will check the cell count of battery automatically After setting the current and voltage press TYPE ENTER ENTER START button for more than seconds STOP START to start the process Charge current 0 1 12 0A Voltage AUTO 1 8 series This shows the number of cells you set up and R 3SER S 3SER the processor detects R shows the number of C
24. ry is not printed on the battery s label consult your battery manufacturer or supplier Do not guess the rated voltage of battery C rating Capacity is also referred to as the C rating Some battery suppliers recommend charge and discharge currents based on the battery C rating A battery s 1C current is the same number as the battery s rated capacity number but noted in mA or amps A 600mAh battery has a 1C current value of 600mA and a 3C current value of 8 x 600mA 1800mA or 1 8A The 1C current value for a 3200mAh battery would be 3200mA 3 24 19 e Balancing the multi Lithium battery packs You can charge and balance several Lithium batteries at the same time by using optional Multi board adaptor 4 Please note that the battery packs being charged should have same capacity and cell count Part no EAC153 EAC154 EAC158 and EAC159 Please read the instructions come with the board for the maximum safety ex 2 x 3S connection using serial charging T Li Po 1S BC8HP T Li Po 2S Individual 7 Li Po 3S bal port Li Po 1S STATION OUTPUT Li Po 2S Multi adaptor 7 Li Po 3S ex 3 x 2S connection using serial charging T Li Po 1S BOHP 7 Li Po2S Individual 7 LiPo 18 Li Po 2S STATION OUTPUT Li Po 1S Multi adaptor 7 Li Po 2S 20 Specifications Oper
25. ss ENTER START button to make it blinking then change the value using INC or DEC button The value will be stored by pressing ENTER START button once BC8HP recognizes the cell count of Lithium battery automatically at the beginning of process to avoid from erroneous setting by user But deeply discharged battery Cm can be perceived incorrectly To prevent the error you DEC INC can set the time term to verify the cell count by the processor Normally 10 minutes are enough to perceive the cell count correctly For the battery of larger capacity you may extend the time term But if you set the time term too long for the battery of smaller capacity the charge or discharge process can be finished within the time term with the erroneous cell count This may cause the fatal result If the processor recognizes the cell count incorrectly at the beginning of charge or discharge process you may extend the time Otherwise you had better use with the default value LiPo Lilo LiFe CHK Time 10min DEC INC NiMH Sensitivity D Peak Default This shows the trigger voltage for automatic charge termination of NiMH and NiCd battery If the trigger voltage is set higher there is a danger of overcharging the battery if it is set lower there is a possibility of premature termination Please refer the technical specification of the battery NiCd Sensitivity Disable Delicate Default 5nV 20mV cell D Peak Default D

Download Pdf Manuals