Mastervolt MASS 12/30-2 Product specifications

image

Contents

1. C Y EMR 2 thee Lp RAN SINE WAVE POWER Mastervolt Guarantee Plan 2 year product warranty worldwide service pure sine wave power galvanic isolation 38 Overview sine wave inverter charger combinations Mass Article no 230 V 50 Hz Article no 120 V 60 Hz SINE WAVE INVERTER SPECIFICATIONS DC input voltage nominal Continuous power 25 C Surge capability 5 sec resistive Parallel use to double the power Parallel with shore generator for more power Mass Combi 12 1200 60 36011205 n a I2 V 10 to 15 V 1200 VA 5 3 A 2400 VA 10 5 A no yes Output voltage adjustable via MasterAdjust software 230 V 5 Frequency Output waveform Max efficiency No load consumption 230 V Search mode consumption setting range Dimensions in mm hxwxd Weight Mass Combi 12 2000 100 36012005 37012005 12 V 10 to 15 V 2000 8 7 A 4000 VA 17 5 yes yes 230 V 5 Mass Combi 12 2500 125 available April 2008 I2 V 10 to 15 V 2500 VA 10 9 5000 VA 21 8A yes yes 230 V 5 50 Hz 0 003 60 Hz selectable true sine wave true sine wave true sine wave 9296 9296 9296 9 W lt 9 W 9W 0 5 W 40 150 VA 0 5 W 40 150 VA 0 5 W 40 150 VA 371 x 318 x 143 460 5 x 318 143 460 5 x 318 x 143 7 8 kg kg kg AUTOMATIC BATTERY CHARGER SPECIFICATIONS Input voltage nomina
2. MAGIC 12 12 20 MAGIC 12 24 10 X MasterShunt DC Distribution DC Switching MasterView Classic MasterView Easy MasterView System X IVO Smart 12 10 IP65 IVO Smart 12 15 2 IVO Smart 24 6 IP65 IVO Smart 12 35 3 IVO Smart 12 50 3 IVO Smart 24 15 3 IVO Smart 12 30 2 IVO Smart 12 50 2 Mass 12 30 2 Mass 12 60 2 Mass 12 80 2 Mass 24 15 2 Mass 24 25 2 Mass 24 50 2 Mass 24 75 C Mass 24 100 C Mass 24 100 3ph Mass 48 25 Mass 48 50 Mass 24 50 2 Mass 24 100 Mass Combi 12 1200 60 Mass Combi 12 2000 100A Mass Combi 12 4000 200A Mass Combi 24 1200 35A Mass Combi 24 2000 60A Mass Combi 24 4000 120A X qQOXOX XX XXX XXXIX ChargeMaster 12 70 3 ChargeMaster 12 100 3 ChargeMaster 24 40 3 ChargeMaster 24 60 3 ChargeMaster 24 80 3 ChargeMaster 24 100 3 Mass Systemswitch X Functions for Mass Combi The Mass Combi MasterAdjust software allows you to easily check the status of the charger inverter and transfer system and to set the parameters of your Mass Combi so as to meet your personal requirements Although the Mass Combi can be directly installed and used without the need for c
3. C 4 RI 70404110 Remote control on off for Mass sine wave inverter MasterView Easy 77010300 The MasterView Easy panel in combination with a MasterShunt art no 77020100 is the world s most advanced battery monitor TECHNICAL SPECIFICATIONS Number of battery sets 2 battery banks 3 battery banks 3 battery banks n a battery bank n a one battery set per MasterShunt Readout voltage yes yes yes yes AC yes n a yes Readout current yes yes no yes AC power yes n a yes Readout Amp hours yes yes no no no n a yes Time remaining indication yes yes no no no n a yes Battery capacity in 96 yes yes yes no no n a yes Inverter operation yes no no no yes yes yes Battery charger operation yes no no no yes no yes Power Sharing adjustment yes no no yes no no yes Compatible with MasterVision yes yes yes optional optional optoinal no Current consumption backlight off 28 mA I2 V 26 mA 24 V I4 mA I2V 11 mA 24 V 15 mA n a n a n a 32 mA I2 V 17 mA 24 V Current consumption backlight on 100 mA I2 V 50 mA 24 V 100 mA I2 V 50 mA 24 V 100 mA I2 V 50 mA 24 V n a n a n a 100 mA I2 V 50mA 24 V Supply voltage 9 to 35 V DC 9 to 35 V DC 9 to 32V DC n a n a n a 9 to 60 V DC Voltage range measurement 7 to 35 V DC 7 to 35 V DC 7 to 32V DC 180 to 260 V AC 7 to 35 V DC n a 0 to 60 V DC Voltage resolution 0 05 V 0 01 V 0 1 V n a n a n
4. Equalization charge selecteable Display mode In normal operation mode the controller displays the state of charge available energy of the battery Any change of the state of charge SOC to a lower status is additionally signaled acoustically The display percentage corresponds to the available energy until Low Voltage Disconnect in relation to a fully charged battery As long as the solar array supplies enough voltage to charge the battery this is indicated by up moving bars alternately to the state of charge display Load management In normal operation the loads can be switched on and off by pushing the button This is indicated in the display Advance features Low voltage disconnect function The solar charge controller has multiple modes to protect the battery from being discharged and is factory programmed to the following load settings disconnect at 11 4 V up to 11 9 V Nighlight timer function The controller comes with a sophisticated nightlight function It controls the load output at night The controller recognizes day and night based on the solar open circuit voltage In the programming menu this day and night threshold setting can be modified according to the requirements of the local conditions and solar array used management for Streetlights Advanced programming function The controller has an advanced programming mode for the setting of advanced features Battery setting low voltage disconnect setting n
5. frame earthing VDS l6 mm VD 3x2 5mm phase VD 3x2 5mm phase B 16A 3P N Module Astropower AP75 Voc 33 0 V stc Vmpp 26 0 V Usc 4 3 A stc Impp 4 23 A existing groups distribution board 15 kWp system installed in Greece This system was installed at the end of 2003 by a local Greek company on a building near Athens A total of 200 75 Wp Astropower solar panels supply 15 kWp of power for local consumption and returning to the grid Six Sunmaster 053200 inverters are placed between the solar panels and the grid This is powerful system that meets the required energy needs virtually autonomously QS3200 phase 3 Frequently asked questions on PV systems 1 What is the best angle for solar panels The optimal angle for placing solar panels is 50 for systems in Nordic countries and 20 for South European countries 2 How much power will I lose if panels are incorrectly placed A system set at an angle of between 20 and 50 facing south will produce around 596 less power per year When panels are installed at an angle of 35 and the system is oriented between south east and south west the energy shortfall on an annual basis will again be around 596 3 How does heat affect my system The output of a system is reduced when panels become warmer The power shortfall be 0 3 to 0 5 per C 4 What is the life span of a solar panel With proper maintenance the modules s
6. MASTERVOLT POLAND MASTERVOLT SCANDINAVIA AB MASTERVOLT SPAIN SL MASTERVOLT UK LTD Please refer to our website www mastervolt com for an actual list of our international authorised dealers Version no EN210108 Article no 5000041 30 ASTERVOLT THE POWER TO BE INDEPENDENT
7. 130394410 Data Control Pro 230 V ISDN in enclosure art no 130396310 DC Pro irradiance and temperature sensor O to 10 V art no 130394400 i 5 diem iy DC Pro ambient temperature sensor 0 to 10 V art 130394420 Documentation CD Data Control Pro includes user manual installation information and drawings PTIOO converter art no 130394440 30 Electrical power systems for absolute independence Solar modules are eminently suitable as a source of energy also in areas where the electricity network is unreliable or nonexistent Any extra power generated is stored in an energy buffer the battery and the optional monitoring system helps keep track of power consumption Mastervolt offers a wide range of sine wave inverters and combis that convert raw electricity generated by PV or wind generators into a clean and stable universally applicable AC voltage DC connection Equipment needed for autonomous grid independent systems 1 Solar modules not provided by Mastervolt Battery charge regulator with MPP tracker Mastervolt sine wave inverter charger e g Mass Combi System monitoring mn W N Back up generator Mastervolt inverters and combis deliver 230 V 50 Hz or 120 V 60 Hz sine wave power for lamps refrigerators computers tools water pumps and various other appliances Dakar and Mass Combi models incorporate an advanced three stage b
8. MasterView optional art no 70405010 Indication of AC consumption AC voltage and the fuse value of the shore generator connection Masterlink MICC optional optional option MasterView optional optional optional option MasterView optional art no 70403105 Battery consumption meter 12 24 V DC with LCD readout and remote control for Mass Sine inverter and battery charger or Mass Combi Mastervolt Guarantee Plan 9942 A YEAR SINE WAVE POWER e 2 year product warranty worldwide service Mastervolt 3 stepO charging method pure sine wave power galvanic isolation e 3STEP U 40 Overview battery chargers IVO amp Mass range IVO Smart IVO Compact Mass Mass IVO Smart Mass Mass Mass Mass Mass 12 10 IP65 12 25 3 12 60 2 12 80 2 24 6 IP65 24 50 2 24 100 C 24 100 3ph 48 25 48 50 Article no 43011000 43012500 40010600 40010800 43020600 40020500 40021005 40031000 40040250 40040500 GENERAL SPECIFICATIONS Nominal input voltage 230 V 180 to 250 V 120 230 V auto 230 V 180 to 250 V 4 2 230 V 180 to 250 V 3x400 V 360to 485 V 230 V 180 to 250 V Nominal output voltage I2 V 2 2 2 24 V 24 V 24 V 24 V 48 V 48 V Total charge current IOA 25 A 60 A 80 A 6 A 50 A 100 A 100 A 25 A 50 A Number of battery outlets 3 2 2 2 Charge current second third output n a 25 A 3 3A 3A n a 3A
9. Premium data logger continuously communicates with all connected inverters and saves all current measured values and system data every 10 minutes The device offers a large data memory for values measured over a period of up to three years depending on the configuration A QS data port connects all the inverters with the data logger Specifications Data Control Premium 11 and XS systems Premium Local Ethernet imi Data registration module for Sunmaster QS es E panum 5 Premium Remote Modem Article number 30396000 130396100 HOUSING Dimensions hxwxd 90 x 160 x 73 mm 6 TE 90 x 160 x 73 mm 6 TE Installation hat rails hat rails Mode of protection IP20 IP20 Temperature range 0 C to 55 C 0155 VOLTAGE SUPPLY Power pack 230 V internal internal Voltage supply sensors yes 24 V yes 24 V INPUTS OUTPUTS Analogue irradiation Digital kWh counter Outputs alarm large size display INTERFACES COMMUNICATION RS485 QS Databus Ethernet network PC l Modem analogue DATA READOUT Internet portal yes PC software yes ALARM FUNCTION E mail via network yes SMS no Fax no Visual yes Acoustic option Recorded values In addition to energy irradiation and operating hours numerous additional measured values are recorded Energy yield and operating hours Total ene
10. cos phi 500 VA 800 VA 1200 VA 2000 VA 800 VA 1500 VA 2500 VA 5000 VA 10 kVA 15 kVA 2500 VA Nom power Tamb 40 C cos phi 450 VA 650 VA 1000 VA 1800 VA 650 VA 1200 VA 2000 VA 4000 VA 8 kVA 13 kVA 2000 VA Peak load 1000 VA 1600 VA 2400 VA 4000 VA 1600 VA 2900 VA 5000 VA 10000 VA 20 kVA 30 kVA 5000 VA Output waveform true sine true sine true sine true sine true sine true sine true sine true sine true sine true sine true sine Max efficiency 91 92 92 92 92 92 92 90 92 92 92 Output voltage 230 V 5 230 V 5 230 V 5 230 V 5 230 V 5 230 V 5 230 V 5 230 V 5 230 V 5 230 V 5 230 V 5 Frequency 111 1 1 1 1 00 50Hz 0 005 also available in 60Hz JJ 50Hz 0 005 also available in 60Hz Dimensions in mm hxwxd 313x187x 82 325 220 x III 340 x 261 x 130 420 x 318 x 130 325 x 220 x III 340x 261x130 420x318x 130 475 5 318 254 2x C4 C5 3x C4 C5 420x 318x 130 Weight 3 4 kg 3 9 kg 6 kg 9 4 kg 3 9 kg 6 kg 9 7 kg 19 kg 44 kg 55 kg 9 7 kg Minimum battery capacity gt 100 Ah gt 00 Ah gt 50 Ah gt 200 Ah gt 50 gt 150 Ah gt 200 Ah gt 400 Ah gt 500 Ah gt 800 Ah gt 100 Ah TECHNICAL SPECIFICATIONS Switch off voltage low battery 10 V 0 5 V 10 V 0 5 V IO V 0 5 V 10 V 0 5 V 19 V 0 5 V 19 V 0 5 V 19 V 0 5 V 19 V 0 5 V 19 V 0 5 V 19 V 0 5 V
11. 10 xx 20 INTERFACES Input analogue 4 0 to 20 mA 0 to 10 V Input digital 4 meters status Bus connection RS485 Internet connection Ethernet Alarm output 24 V DC 230 V AC 2 ELECTRICAL DATA Grid connection 230 V AC Power 2 W max MECHANICAL DATA Dimensions hxwxd 90 x 160 x 73 mm Mounting hat rail mounting Protection degree IP20 ENVIRONMENTAL CONDITIONS Operating temp 0O 655 Storage temp 20 C to 65 C Data logger all current measured values and system data of the inverters Data Control Pro 230 V GSM modem art no 130396220 Accessories Data Monitoring MINIATURE WEB SERVER compared to the sun irradiation Data recording and evaluation with Safer Sun Automatic daily data recording with high resolution Evaluation per day month and year Graphic data display Alarm messages via fax SMS email Automatic comparison with the actual regional irradiance data Worldwide access through the Internet A QS data port connects all the inverters with the data logger Data Control Basic PC Link Model RS485 USB ISO art no 130391010 art no 130391040 Model RS485 232 converter art no 130391020 PC Link Industrial for the connection of more than 10 Sunmasters or 25 mtr connection cable Data Control Premium amp Data Control Pro 29 DC Pro irradiance sensor 0 to 10 V temp compensated art no
12. 36 V 0 5 V Switch on voltage low battery V 0 5 V V 0 5 V V 0 5 V V 0 5 V 22 V 0 5 V 22 V 0 5 V 22 V 0 5 V 22 V 0 5 V 22 V 0 5 V 22 V 0 5 V 44 V 0 5 V Switch off voltage high battery 15 5 V 0 5 V 15 5 V 0 5 V 15 5 V 0 5 V I5 V x0 5 V 3l V x0 5 V 33 V 0 5 V 33 V 0 5 V 33 V 0 5V 32 V 0 5 V 33 V 0 5 V 62 V 50 5 V Switch on voltage high battery 14 5 V 0 5 V 14 5 V 0 5 V 14 5 V x0 5 V 14 5 V 0 5 V 30 V 0 5 V 3l V x0 5 V 3l V 0 5 V 3l V 0 5 V 3l V x0 5V 31 V 0 5 V 59 V 0 5 V Max allowable ripple on DC 5 RMS 5 RMS 5 RMS 5 RMS 5 RMS 5 RMS 5 RMS 5 RMS 5 RMS 5 RMS 5 RMS Input current nominal load 23 A 38 A 42 A 68 A 34 A 70 A 120 A 240 A 4x 120 A 6x 120 A 60 A No load power consumption stand by mode 43 mA 0 5 W 65 mA 0 8 W 43 mA 0 5 W 50 mA 0 6 W 35 mA 0 8 W 25 mA 0 6 W 25 mA 0 6 W n a lt 10 412 lt 10 412 13 0 7 W low energy mode 208 V 300 mA3 6 W 410 mA 4 9 W 420 mA 4 5 W 420 mA 5 W 200 mA 4 9 W 180 mA 4 5 W 225 mA 5 4 W n a n a n a 110 mA 5 4 W high power mode 230 V 325 mA 3 9 W 470 mA 5 6 W 450 mA 5 W 480 mA 6 W 240 mA 5 6 W 200 A 5 W 250 A 6 W 250 mA 6 W 150 W 180 W 125 mA 6 W DC fuse required slow blow 100A 100 A 120 A 240 A 63 A 100 A 160 A 2x 160 A 4x 160 A 6x 160A 100A Minimum DC cable size 16 mm 25 mm 50 mm 70 mm l6 mm 25 mm 50 mm 2x 50 mm 50 6x 50 mm 50 37 Harmonic distortion typical
13. 396 396 396 396 396 396 396 396 2 596 2 596 396 AC connection single phase 3 wire internal internal internal internal internal internal internal internal internal internal Cos Phi p rmn z all power factors allowed 92259 2922922202 4 4 4 all power factors allowed OPTIONS Model C4 RI ET remote control on off for Mass Sine inverter J 2 remote control on off for Mass Sine inverter art no 70404110 Masterlink MICC battery consumption meter 12 24 V DC with LCD readout remote control for Mass Sine inverter and battery charger Mass Combi n a System Manager MICC battery consumption meter 12 24 V DC with LCD readout and LED bar comprehensive remote control for Mass Sine inverter and Mass charger n a art no 70400115 Transfer system Also available for 48 V art no 48 500 24040500 15 load reduction for the 120 V 60 Hz models C4 enclosure 460 6 x 318 143 mm C5 enclosure 475 5 x 318 x 254 mm hxwxd
14. Basic programme gives a schematic overview of the PV system s performance including Power and operational hours over a ten day period Voltage current and load of the solar panels current values Voltage current and frequency of the 230 V grid current values Internal temperature total power kWh total hours of operation Read out of the number of returned amperes output side Grid voltage current and frequency output side Read out of the temperature of the Sunmaster total output in kWh status of operational hours Current status and error messages For our extended monitoring program see page 26 to 29 art no 130391010 20 Sunmaster QS6400 IP23 product specifications QS6400 256400 Max l Generic article no 130606400 130706400 see the Mastervolt price list for the specific country versions and article numbers GENERAL Typical string length 4 to 6 modules of 72 cells 6 to 9 modules of 54 cells or 8 to 12 modules of 36 cells 5 to 9 modules of 72 cells 7 to 12 modules of 54 cells or 10 to 18 modules of 36 cells Operating temperature 20 C to 50 C protected against high temperatures Storage temperature 20 C to 70 C 20 C to 70 C Relative humidity max 95 not condensating PCB has anti moisture coating Protection degree IP23 IP23 Safety class class class Galvanic isolation class Il class II D
15. Hz 35 28 5 V 1170 VA 5 1 A 28 5 26 5 V 50A 25 10 ms Mass Combi 24 2000 60 36022005 37022005 24 V 20 to 31 V 2000 8 7 A 4000 VA 17 5 yes yes 230 V 5 true sine wave 9296 9 W 0 5 W 40 150 VA 460 5 x 318 143 kg 230 V 180 to 265 V 45 to 65 Hz 60 A 28 5 V 1965 VA 8 5 A 28 5 26 5 V 50A 25 A 10 ms 596 Mass Combi 24 2500 75 available April 2008 24 V 20 to 31 V 2500 VA 10 9 5000 VA 21 8A yes yes 230 V 5 true sine wave 9296 lt 9 W 0 5 W 40 150 VA 460 5 x 318 x 143 ll kg 230 V 180 to 265 V 45 to 65 Hz 75 A 28 5 V 2455 VA 10 7 A 28 5 26 5 V 50A 50A 10 ms 596 Mass Combi 24 4000 100 36024005 37024005 24 V 20 to 31 V 3750 16 5 7500 VA 32A no yes 230 V 15 true sine wav 9296 9W W 40 150 460 5 x 318 x 266 21 kg 230 V 180 to 265 V 45 to 65 Hz 120 A 28 5 V 3900 VA I7 28 5 26 5 V 50A 39 25 A 35 A Q 120 V 10 ms Remote ICC Hif T optional delivered as standard option MasterView delivered as standard optional delivered as standard option MasterView delivered as standard art no 70405000 Indication of DC consumption charge phase failure and AC availability With on off charger only switch Standard equipped with 6 metre cable Remote APC Hid optional optional option MasterView optional optional optional option
16. W 1800W 3500 W 3500 W 1800 W 3500 W Temperature compensation by means of a sensor n a 30 mV C 30 mV C 30 mV C n a 60 mV C 60 mV C 60 mV C 120 mV C 120 mV C Temperature range 0 C to 60 fully safeguarded against overheating and short circuiting 0 C to 60 C fully safeguarded against overheating and short circuiting Cooling natural cooling vario fan vario fan vario fan natural cooling vario fan vario fan vario fan vario fan vario fan Protection degree IP65 IP21 IP23 IP23 IP65 IP23 IP23 IP23 IP23 IP23 Approvals generic emission and interference standard EN 55014 1 1993 generic harmonic current emis sions EN61000 3 3 1995 generic amp safety accreditations immunity standard EN 55014 2 1997 electrostatic discharge EN 61000 4 2 1995 electrical fast transients EN 61000 4 4 1995 surge transient EN61000 4 5 1995 conducted radio frequency interference EN61000 4 6 1996 voltage dips EN 61000 4 11 1994 OPTIONS 41 Remote CC n a yes yes yes n a yes yes yes yes yes art no 70405030 Indication of charge phase charge current and battery charger operation Model C4 RB n a n a yes yes n a yes yes yes yes yes art no 70404100 Monitoring panel for Mass and IVO battery charger Model C3 RS n a yes yes yes n a yes yes yes yes yes art no 70403040 Remote monitor for battery chargers with c
17. by the photovoltaic strings into alternating current and feed it into the public mains At the same time they are used for system monitoring These extremely compact easy to mount and lightweight devices offer the highest annual efficiency rates high reliability and extensive monitoring functions The various models cover a performance range of 100 to 7200 Wp PV systems with low to very high outputs can be configured flexibly one input Soladin 600 and QS2000 two inputs QS3500 and 56500 three inputs XLIO and XLI5 or even four inputs QS6400 with independent MPP trackers are available to which two module strings of the same design can be connected In addition two phase feeding into the mains above 5 kW is possible with the QS6400 On the output side the devices can be connected in parallel in any desired combination and number The standard models convert string currents from 7 5 A up to 30 A and string voltages from 100 to 600 V DC per input with MPP control The models 053500 and QS6400 Max l especially designed for high current modules convert 0 and 75 to 260 V DC Industry leading benefits Mounted in robust aluminium cabinets and designed for use in closed rooms our inverters convert power with the latest high frequency technology Sunmaster QS3500 Sunmaster QS2000 There are numerous advantages Exceptional efficiency offers high yield scores even in the par tial load range and minimal stan
18. capacity The battery should then be cross wired to the system using the plus pole of the first and minus pole of the last battery 12V 200Ah 12V 200Ah o e 12V 200Ah 12V 200Ah 24 V 400 Ah series parallel connection Tec oc 12V 200Ah 12V 200Ah 12V 200Ah 12V 200Ah 48 V 200 Ah series connection 46 Overview of battery monitoring panels amp inverter charger A Mastervolt battery monitoring system brings an end to unpleasant surprises A clear display shows performance consumption and available battery capacity Below we have listed the available monitoring panels for Mass Sine Mass Combi and Dakar Combi models Article no Application Masterlink MICC 70403105 Battery consumption meter 12 24 V DC with LCD readout Remote control for Mass Sine inverter and battery charger or Mass Combi Masterlink BTM III 70403163 Battery consumption meter 12 24 V DC with LCD readout and LED bar Also available for 48 V DC Masterlink DCV 70403180 Battery condition meter for three independent batteries 12 24 V DC remote panels APC remote control for Mass Combi 70405010 Indication of AC consumption AC voltage and the fuse value of the shore generator connection With Power Sharing setting Modell ICC for Mass Combi standard 70405000 Indication of DC consumption charge phase failure and AC availability With on off charger only switch
19. connected in parallel the current will add up with the number of units connected in parallel while voltage remains constant With both parallel or series connection the total power generated is the sum of all the power generated by the connected solar cells Underdimensioning Means that the nominal input power of an inverter is less than the power of the PV array expressed in kWp In one year the solar array will seldom generate the specified Watt peak power In Northern Europe the inverter input power can generally be chosen to be around 8096 of the PV capacity without introducing significant losses Watt peak Wp A measure of the electrical power a solar cell or module will generate at standard conditions See also STC Working principle of a solar cell Solar cells consist of two layers of semi conducting material usually silicon Between these two layers the n layer above and the p layer below is an electric field When sunlight shines on the n layer it is partly absorbed by the semi conductor and converted into energy heat This energy generates electrons that are free to move through the material The crystalline structure of the silicon and the electrical field ensure that the free electrons move in a certain direction This phenomenon is called electricity and the flow is taken from the cell for use in external applications 5 52 System example grid connected DC switch 440V DC 10A double pole
20. cycle Minimum duration of the absorption phase Maximum duration of the absorption phase 50 Technical definitions Amorphous silicon solar cells The term amorphous refers to the non crystalline structure of silicon atoms The efficiency is lower than crystalline silicon and typically ranges from 596 to 1096 The energy yield per installed Watt peak is higher compared to crystalline silicon modules because of the relatively high efficiency at low irradiation Autonomous PV systems Supply electricity to locations where no public grid is available or a long distance from that grid In such situations a PV system is significantly cheaper than connecting to the mains or a non stop generator Energy neutral building A building where the balance between energy production and energy consumption is zero on a yearly basis This can be achieved by installing various renewable energy sources like PV cells hot water systems heat pumps etc Grid connected PV system The low voltage direct current DC electricity is converted to 230 V alternating current AC power by an inverter The inverter feeds the electricity produced by the PV system back into the utility grid This means the PV system actually functions as a mini power station If the solar energy production is higher than the electricity consumption at any given moment most electricity meters spin backwards The returned electricity is automatically incorporated
21. electrical resistance within a closed current loop This resistance causes the shaded cells to heat up and if the temperature rises sufficiently to break down the Hot Spot effect To prevent this small groups of cells are protected by a bypass diode that stops the shaded solar cells from heating up Silicon Raw material for solar cells Solar cell In a solar cell light energy photons is converted into electric power See also Working principle of a solar cell Solar energy applications The active or passive heating of buildings The heating of tap water The generation of electricity photovoltaic solar energy or PV Solar panel A group of PV cells combined in one unit STC or standard conditions Conditions used to set the panel capacity a cell temperature of 25 C and light intensity of 1000 W m String A group of solar cells or solar panels connected in a series When solar cells or modules are series connected the voltage will add up with the number of cells modules while the current is equal to the current of one cell Because of the relatively low current electrical losses in wiring are low as well A string of cells or modules performs only as well as the worst cell module in the string If differences between solar cells or panels are significant it may be worthwhile separating lower performance modules from higher and combining them into separate strings If cells modules or strings are
22. optional 3 A optional 3 A n a n a Charge characteristic IUoUo automatic 3 step IUoUo automatic 3 step Charge voltage Bulk 25 C 14 40 V 14 40 V 14 25 V 14 25 V 28 80 V 28 50 V 28 50 V 28 50 V 57 0 V 57 0 V Charge voltage Absorption 25 C 14 25 V 14 25 V 14 25 V 14 25 V 28 50 V 28 50 V 28 50 V 28 50 V 57 0 V 57 0 V Charge voltage Float wet 25 C 13 25 V 13 25 V 13 25 V 13 25 V 26 50 V 26 50 V 26 50 V 26 50 V 53 0 V 53 0 V Charge voltage Float gel AGM 25 13 80 V 13 80 V 13 80 V 13 80 V 27 60 V 27 60 V 27 60 V 27 60 V 55 2 V 55 2 V Max absorption time 6 hours 6 hours 6 hours 6 hours 6 hours 6 hours 6 hours 6 hours 6 hours 6 hours Min absorption time 5 min 5 min 5 min 5 5 min 5 min 5 min 5 min 5 min 5 Dimensions in mm hxwxd 180 x 121 x 50 228 x 153 x 82 340 x 261 x 130 340 x 261 x 130 180 x I21 x 50 340 x 261 x 130 420 x 318 x 130 420 x 318 x 130 340 x 261 x 130 420 x 318 x 130 Weight kg 8 kg 4 6 kg 4 6 kg kg 4 6 kg 7 7 kg 7 7 kg 4 6 kg 7 7 kg Battery capacity recommendation 25 to 150 Ah 50 to 300 Ah 120 to 600 Ah 160 to 800 Ah 25 to 100 Ah 100 to 500 Ah 200 to 1000 Ah 200 to 1000 Ah 50 to 250 Ah 100 to 500 Ah TECHNICAL SPECIFICATIONS Power factor regulation 20 95 0 99 20 95 20 95 20 95 20 95 20 95 20 95 20 95 20 95 Full load consumption 230 V AC 170W 440 W 1100 W 1400 W 210
23. setting Power factor 0 99 0 99 0 99 gt 0 99 Harmonic distortion THD 396 at rated load in compliance with IEEE p929 Standby power 0 W 0 W 0 W lt 0 5 W European efficiency 9496 9496 94 596 9596 Maximum efficiency 9596 9596 9596 9696 connection 7 z PG 13 5 gland screw terminals 2 5 to 4 mm Dynamic two string connections each are connected in parallel In Germany 4600 W single phase AS C YEAR eM ARAN Mastervolt Guarantee Plan 5 year product warranty worldwide service 48 hour replacement service sunmaster 44 product specifications SAFETY DEVICES General galvanic separation between DC and AC side by means of a class HF transformer Island protection ENS models redundant impedance voltage and frequency window monitoring independent switch off by two pole relay and solid state switch VDE V 0126 1 1 2006 compliant QNS models redundant voltage and frequency window monitoring independent switch off by two pole relay and solid state switch UK models software controlled frequency adjustment according to G83 Temperature protection DC side protection AC side protection Reclosure time MONITO
24. software with telephone and modem dial up facilities Data Control Professional datalogger using meteo data from the internet Certificates All Sunmaster solar inverters have been approved by local authorities which is indispensible guarantee for safe and reliable functioning The certificates in the Download amp Support Area of our www mastervolt com website represent some of the documents we have obtained allowing trouble free use in the United Kingdom Germany the Netherlands Denmark the Scandinavian countries Spain France Italy Greece Cyprus and Korea 315 Dimensions QS6400 and QS6400 Max l in mm 22 New Sunmaster XL series for high power PV systems The most recent development is a new high power solar inverter with a power rating between 10 and 15 kW The new Sunmaster XL models are delivered in a waterproof IP55 enclosure which can be installed in either a grid connected solar tracker system or a stationary PV system The inverter consists of three highly efficient switch mode power modules of 3 3 or 5 kW power rating each dependent on the model The unit has an operating DC voltage window of 100 600 V DC Galvanic isolation is provided by class high frequency trans formers The output voltage is 230 V AC three phase 50 Hz Islanding protection is foreseen according to local standards Extended di
25. sulphuric acid mixture is as follows percentage battery specific percentage charged voltage gravity discharged 096 11 64 Volt 1 100 100 20 11 88 Volt 1 140 80 40 12 09 Volt 1 175 60 60 12 30 Volt 1 210 40 80 12 51 Volt 1 245 20 100 12 72 Volt 1 280 0 Different types of battery in terms of the thickness and number of plates per cell correspond to different applications The maximum current that can be delivered is determined by the total plate surface The number of times that a battery can be discharged and recharged the number of cycles depends on the thickness of the plates A battery can feature either many thin plates or a few thick ones The starter battery A starter battery has many thin plates per cell leading to a large total plate surface This type of battery is therefore suitable for delivering a high level of current over a short period of time The number of times that a starter battery can be heavily dis charged is limited to around 50 But as starting the engine uses only a small part of the energy stored around 0 01 the battery lasts for many years This type of battery is unsuitable for cyclical use as a service battery Mastervolt s AGM and gel batteries are suitable to be used as starter batteries The semi traction battery A semi traction battery has fewer but thicker plates in each cell These batteries supply relatively less starter current bu
26. the outside world in various ways This optimises the user friendliness of Mastervolt power systems and makes interfacing with other onboard functions possible With this purpose in mind the following protocols have been developed MasterBus System intended for all communications between the Mastervolt system components As it is a closed MasterBus system it is not able to communicate with other systems MassNet Open protocol for communication with the outside world and the Mastervolt system components which are in mutual communication with MasterBus Using MassNet Mastervolt system information and controls can be easily integrated MasterAdjust software Order handy and up to date MasterAdjust software free from the Mastervolt website This software can be used by the installer to accurately tune Mastervolt equipment to its relevant application and allows various parameters to be read and set according to need Parameters such as voltage current switch off points and charging algorithms are just a few of the many options for adjust ment MasterBus USB interface The MasterBus USB interface enables communication between PC laptop and all MasterBus products lt is possible to adapt specific installations or functions to the demands of the power system MasterBus PC Link In order to make use of MasterAdjust software you will usually need a MasterBus PC Link to serve as an interface between your computer laptop and M
27. to recharge these batteries is around 2 7V per cell or 16 2V for a 12V system and 32 4V for a 24V system These high levels of voltage are extremely dangerous for the connected equipment and the large amount of gas generated makes these batteries unsuitable for use on board boats Mastervolt recommends to install maintenance free 2 volt gel cells An appropriate charge protocol should be followed 100 EN Mastervolt gel ES starter battery 80 25 6096 discharge at 800 cycli discharge in 96 500 100 1500 2000 2500 3000 CYCLIC VERSUS LIFE SPAN Parallel connection Parallel coupling involves connecting the plus poles of multiple batteries to each other and the same with the minus poles The plus of the first battery and the minus of the last battery are then connected to the system This type of arrangement is used to increase capacity in this case 400 Ah 2 9 12V 200Ah 12V 200Ah 12 V 400 Ah parallel coupling Series connection Batteries are coupled in series to gain higher voltage for instance 24 or even 48 Volt The plus pole of each battery is connected to the minus pole of the following one with the minus pole of the first battery and plus pole of the last battery connected to the system Tec oo 12V 200Ah 12V 200Ah 24 V 200 Ah series connection Series parallel connection A combination of series and parallel connections is required if you need for example a 24 Volt battery set with a higher
28. x 207 x 693 212x 192 693 211 x 234 x 693 211 x 276 x 693 211 x 276 x 843 214 399 819 214 488 819 Installation length 134 mm 134 mm 155 mm 176 mm 155 mm 210 mm 220 mm 220 mm 220 mm 223 mm 222 mm Number of pole pairs l l l l 2 2 2 2 3 4 Weight 22 kg 32 kg 37 kg 42 kg 50 kg 68 kg 82 kg 98 kg 112 kg 153 kg 196 kg Guarantee period 12 V battery set consists of six 2 V elements while 24 V configuration consists of twelve elements The sets are supplied complete with connection cables to connect the poles All models are suitable for both horizontal and vertical mounting rack or stack configuration allowed CIO stands for capacity at a discharge time of 10 hours at 10 discharge rate See next pages for comprehensive battery information 2 year product warranty 7 year product warranty 2 V cells worldwide service AS C3 pt RAS Mastervolt Guarantee Plan 44 Your battery as a power source Mastervolt gel batteries There are different kinds of rechargeable batteries The most common and widespread type is the lead acid battery A less familiar one is the nickel cadmium NiCad battery which can still often be found in old emergency power systems Due to the complex charge method required by a NiCad battery and the fact that they are environmentally unsound these batteries are not suitable for use onboard a boat The principle of the lead acid battery A battery is a device t
29. 180 180 180 180 Cold starter current DIN 492 A 617A 885 A 1249 A ISI8A 1980 2239 IIO A 230 A 270 A 450 A 540 A 630 A Cold starter current SAE 562 A 705 A 1012 A 1425 A 1722 A 2261 A 2557 A 175 A 380A 450 A 760 A 920A 1100A Short circuit current 1500A 1620 A 2700 A 2000 A 3500 A 3650 A 4400 A 583A 1403 2018A 2475 A 3132 A 3606 A IEC 60896 21 Guarantee period 2 year 2 year 2 year 2 year 2 year 2 year 2 year 2 year 2 year 2 year 2 year 2 year 2 year C20 standard battery capacity at a discharge time of 20 hours at 596 discharge rate Compare batteries on the basis of their weight See next pages for comprehensive battery information a j MVSV 280 MVSV 420 MVSV 500 MVSV 580 MVSV 750 MVSV 1000 MVSV 1250 MVSV 1500 MVSV 1650 MVSV 2200 MVSV 2700 2 V gel cell 2 V gel cell 2 V gel cell 2 V gel cell 2 V gel cell 2 V gel cell 2 V gel cell 2 V gel cell 2 V gel cell 2 V gel cell 2 V gel cell a Article no 68000280 68000420 68000500 68000580 68000750 68001000 68001250 68001500 68001650 68002200 68002700 Nominal voltage 2 2 2 V 2V 2 V 2V 2 V 2V 2V 2 V 2 V Capacity 10 280 Ah 420 Ah 500 Ah 580 Ah 750 Ah 1000 Ah 1250 Ah 1500 Ah 1650 Ah 2200 Ah 2700 Ah Dimensions lxwxh in mm excl poles 125 x 207x357 125 207 473 146 207 473 167 207 473 146 x 207 x 648 211 x 192 x 647 211 x 234 x 648 211 x 276 x 648 211 x 276 x 798 214 x 399 x 775 214 x 488 x 774 Dimensions Ixwxh in mm incl poles 125 x 207x401 125x207x517 146 207 517 167 207 517 146
30. 4 QS3500 IP44 QS3500 IP44 XS6500 IP44 Article number 130802000 130803500 130903500 131006500 GENERAL 5 to 9 modules of 72 cells 7 to 12 modules of 54 cells or 10 to 18 modules of 36 cells Typical string length 4 to 6 modules of 72 cells 6 to 9 modules of 54 cells or 8 to 12 modules of 36 cells 12 to 25 modules of 36 cells 7 to 17 modules of 54 cells or 6 to 12 modules of 72 cells Extremely efficient up to 2596 more yield As a result of the advanced switch mode technology applied Mastervolt solar inverters have negligible power loss in the DC to AC conversion process resulting in a much higher AC power return to the grid Even at 596 of nominal power the inverter realizes more than 9096 efficiency The maximum efficiency is almost 9596 which is extremely high considering the input to output galvanic isolation EU efficiency 94 596 Operating temperature 7 20 to 50 protected against overtemperature Storage temperature 20 to 70 C 20 to 70 C 20 to 70 C 20 to 70 C 80 Relative humidity max 9596 not condensating PCB has anti moisture coating 19 Protection degree IP44 IP44 IP44 IP44 gt Safety degree Class Class Class Clas
31. MASTERVOLT SOLAR POWER SYSTEMS conversion solutions for I ccudcoHnestedandautanomous solar systems 202592022 Light and heat The power to stay healthy The capacity to grow The sun is the sustainable source of energy for life on this planet And thanks to modern technology we can optimise the output taken from this energy The sun is a shining example of efficient power generation without harming the environment Turning solar energy with the best possible output into electrical power that comes out of a socket is the ultimate challenge And this is where Mastervolt comes in Mastering the power of the sun Mastervolt develops and manufactures top quality power electronics that converts the power of the sun into usable electrical energy Equally at home with grid connected and autonomous applications Mastervolt is a vital link in PV systems throughout the world Mastervolt A partner with power A reliable energy supply in all places and at all times With this mission Mastervolt has developed into a leading player in a wide range of markets over the past decade On a global scale Mastervolt now plays a key role in the fields of mobile and maritime power provision both recreational and professional And the same applies to solar energy Mastervolt offers the craftsmanship expertise and products you need to turn the power of the sun into high quality energy Custom m
32. Mastervolt s already extended portfolio which includes a wide variety of maintenance free batteries sine wave inverters and inverter charger combinations amp hour counters battery chargers and DC AC distribution components Adding an advanced solar controller is fitting entirely into the famous Mastervolt system approach which is now becoming reality in the autonomous solar field as well Mastervolt developed the Solar ChargeMaster series to guarantee an optimum charging process with cost efficiency This highly advanced equipment converts unstable current from the solar panels into accurate charge current The 3 step charging method guarantees that batteries will be charged safely and efficiently under all circumstances A battery temperature sensor is standard designed to regulate the optimum charge voltage at each temperature to prolong the lifespan of the battery e R NS Mastervolt Guarantee Plan 5 year product warranty worldwide service 48 hour replacement service Description of functions The charge controller protects the battery from being overcharged by the solar array and from being discharged too deeply by the load The charge controller adjusts itself automatically to 12 V or 24 V system voltage Pushbutton to switch the load on and off The charge controller can be programmed for lighting applications Many safety and display functions Negative ground Battery type presets
33. RING On the front External communication Optional monitoring accessories power derating at Tambient gt 40 C switch off at Tindoor gt 90 C earth fault detection over voltage detection polarity protection diodes current limitation transients varistor and buffer capacitor overload temperature controlled power derating current limitation over and undervoltage over and underfrequency short circuit ceramic fuse transients surge varistors 10 to 300 s model dependent integrated LCD display two RS485 connections to connect to the QS databus Data Control Basic software for PC QS PC Link PC adapter for QS databus e Data Control Premium 11 data logger and PC local remote monitoring internet connection Data Control Professional data logger and PC local remote monitoring internet connection using current weather data or optional sensors REGULATIONS amp DIRECTIVES CE conformity yes EMC directive EMC 89 336 EEC Emission EN 50081 55011 EN 55014 EN 55022 VDE 0871 class Harmonics EN 61000 3 2 929 Flicker 61000 3 3 Immunity EN 50082 2 LV directive 73 23 EEC Electrical safety EN 60950 ENS VDE 0126 UK G83 2003 certification AS C YEAR eM ARAN Mastervolt Guarantee Plan 5 year product warranty worldwide service 48 hour replacement service Basic monitoring as standard The Ma
34. V 5 Frequency Dimensions hxwxd 74 x 152 x 242 mm 74 x 152 x 242 mm 74 x 152 x 242 mm 74 x 152 x 242 mm 35 Weight 1 65 kg 1 85 kg 1 65 kg 1 85 kg Protection degree IP21 IP21 IP21 IP21 Min battery capacity gt 50 Ah gt 80 Ah gt 25 Ah gt 40 Ah TECHNICAL SPECIFICATIONS Switch off voltage low battery 10 5 V 0 5 V 10 5 V 0 5 V 21V 0 5 V 21 V 0 5 V Switch on voltage low battery V 0 5 V V 0 5 V 22 V 0 5 V 22 V 0 5 V Switch off voltage high battery l6 V XIV l6V XIV 32y 32V XIV Switch on voltage high battery 15 5 V I V 5 5 V I V V XIV 3I V xIV Max allowable riple on DC 5 RMS 5 RMS 5 RMS 5 RMS Input current nom load 23 A 38 A ISA 25A No load power consumption Off mode 0 mA 0 mA 0 mA 0 mA high power mode 230 V 0 8A 9 6 W 0 8A 9 6 W 0 5 A 12 0 5 12 DC fuse required slow blow 30A 40 A 20A 30A Min DC cable size supplied supplied supplied supplied Harmonic distortion typical 396 396 396 396 Cooling 44 9 e Meeell0 conventional forced conventional forced Cos Phi H all power factors allowed all power factors allowed Operating temperature specified full spec 0 to 40 C ambient t
35. a 0 01 V Voltage deviation 0 6 1 figure 0 6 1 figure 0 6 1 figure n a n a n a 0 6 1 figure Amps measurement range to 500A 0 to 500A n a n a n a n a 0 to 500A Max Amp hour capacity 9999 Ah 9999 Ah 9999 Ah n a n a n a 9999 Ah Shunt specification 500 A 50 mV service set 500 A 50 mV service set n a n a n a n a digital shunt m Dimensions instrument w x h 120 x 65 mm 120 x 65 mm 120 x 65 mm 120 x 24 mm 120 x 24 mm 60 x 65 mm 113 113 mm Built in depth incl excl cover box 55 mm 40 mm 55 mm 40 mm 55 mm 40 mm 18 5 mm 18 5 mm 28 mm surface mount Weight instrument incl shunt 0 9 kg 0 9 kg 0 25 kg 140 gr 140 gr 60 gr 1 2 kg Dimensions shunt hxwxd 84 x 44 x 44 mm M8 84 x 44 x 44 mm M8 n a n a n a n a 228 x 150 x 64 mm Battery alarm contact yes potential free yes open collector yes open collector no no n a yes via MasterBus alarm interface Connection cable 6 wire necessary yes 2 pcs no no yes yes yes MasterBus cable included Art no 6801601200 Languages english english dutch german english english english english english dutch german french italian danish norwegian swedish amp finnish french italian danish norwegian swedish amp finnish oDu 5 amm Y ERR S dii LPR AS Mastervolt Guarantee Plan 2 year product warranty worldwide service 48 Communication using Mastervolt system components Mastervolt equipment communicates with each other and
36. ade power The Sunmaster series Developed for grid connected applications and offering an exceptionally high efficiency Mastervolt Sunmaster inverters get the most out of solar panels The power of global experience Partnering with Mastervolt brings you all the benefits of international experience and know how Whether standalone or connected to the grid our high tech equipment is installed throughout the world by those who value a reliable and sustainable energy supply From isolated villages in Nicaragua to mountain towns in Spain From new residential projects in Germany to the Philippine countryside From America to Asia and Australia In close cooperation with local utility companies and solar module providers Mastervolt ensures that the sun s power is used for the benefit of people For the grid connected PV market alone Mastervolt has an installed base of more than 250 000 solar Mastervolt Switch mode technology makes bulky and heavy inverters around the world Master grid connected inverter systems transformer technology superfluous As a result Sunmaster inverters are exceptionally compact and Mastervolt technology applies international Mastervolt string inverters are integrated in high tech dual axis solar tracking systems These systems increase lightweight Monitoring via a PC is standard and an standards and conforms to national requirements In the production of photovoltaic solar energy by mor
37. agnostics and remote monitoring is delivered as a standard oDy Res CA YEAR Mastervolt Guarantee Plan 5 year product warranty worldwide service 48 hour replacement service mM ARAN Sunmaster XL product specifications GENERAL SPECIFICATIONS Description integrated 3 phase solar inverter consisting of one IP55 Outdoor enclosure and 3 power modules Enclosure and modules to be shipped separately Protection degree Operating temperature 20 C to 60 C ambient full power up to 45 C ambient air temperature derating 3 C above 45 C IP55 enclosure PCB protected against humidity and condensing air by coating Safety class class metal housing with earth connection Galvanic isolation class safety transformer Weight 135 kg 96 kg enclosure 3x 13 kg modules Dimensions hxwxd 1200 x 580 x 480 mm with legs 1408 x 638 x 480 mm Connections power module DC input is fitted with MC2 4mm connectors AC output fitted with 100 cm AC cable 2 5485 communication ports Enclosure mounting positions prepared for 2x 50 cm DIN rail not included SOLAR INPUT DC Model XLIO Model XLI5 Recommended PV power range 9 to 13 kWp 14 to 20 kWp Maximum input power 11 200 W DC 16 800 W DC Continuous power 45 C 10 650 W DC 15 975 W DC Start up power 3x 10 W 3x 10 W Operating voltage 100 to 550 V DC nominal 400 V DC 100 to 600 V DC nominal 400 V DC MPP voltage range no
38. alibration A Mastervolt installer can by means of a password and the Mastervolt website access more advanced functions This way the Mass Combi can be set and calibrated according to the specific technical requirements of the electrical installation The functions described below are available as standard The first screen Status Overview gives you a complete and instant over view on the status of your Mass Combi The readings and settings of the Combi are indicated both graphically and numerically AC system Voltage Current Load Operation mode Monitoring and setting the Power Sharing mode DC system Voltage Current Load Error diagnosis Charge current Status of the 3 step charge characteristic bulk absorption and float You can monitor and adjust all variables in the screen Setpoints Changing the settings of the battery charger e Maximum voltage in the bulk charge phase Maximum charge voltage in the absorption phase Output voltage in the float phase The undervoltage level for the starting of a new charge cycle Forced float voltage constant output voltage in two step charger mode Voltage compensation for the use of gel or AGM batteries Return amps the output current of the battery charger at which the battery is considered to be fully charged Maximum charge current Maximum duration of the bulk phase Return to bulk time delay before the start of a new charge
39. ar PV application is the connection of solar panels to the electricity network This type of grid connected system functions as a miniature power station Whenever the solar power production is higher than the consumption the extra electricity is fed back into the public grid Electricity companies pay handsomely for this kWh generation in an increasing number of countries such as Japan Germany Italy Spain Belgium the United States and an increasing number of countries in the Asia Pacific region DC connection Basic equipment required for a grid connected system Solar modules not provided by Mastervolt Mastervolt solar inverter with integrated kWh meter Mastervolt data logger for monitoring optional DC connection The Mastervolt inverter is the dynamic heart of any grid connected PV system The power conversion system takes place with minimal power loss and maximum reliability while extensive system monitoring offers accurate actual and historical data The products available for these applications are described on the following pages The diagram below shows all the ingredients of a grid connected power system AC connection 2 3 4 A kWh meter for the registration of generated and used power not provided by Mastervolt 5 Energy consumers in the house not provided by Mastervolt Sunmaster XS6500 The heart of any PV system Mastervolt solar inverters convert direct current generated
40. are guaranteed even in the most arduous of locations The IP44 waterproof enclosure allows for installation in most protected outdoor areas Once connected to the PV modules in your system the low weight inverter delivers the power Both on a bright midsummer day when it s 40 C or more and on cloudy winter morning Sometimes even in bright moonlight Mounting bracket supplied as standard Corossion proof steel metal Sunmaster IP44 range e Sunmaster 052000 e Sunmaster 053500 Sunmaster 053500 Max l e Sunmaster XS6500 offering 5 kW cont output connect inverters from Mastervolt Our world proven HF transformer technology is as ever built in to a compact housing making installation simple and quick Integrated heavy duty DC load switching adds to greater safety and simplicity in use this comes standard on all ENS versions Mastervolt is proud to offer you yet another innovative product with the introduction of a new and advanced LCD display with miniature data logger storage of data for up to 30 days giving you the profitable facts No more guesswork Aluminium all weather resistant enclosure Location for type sticker Excellent access to all in and output connections have been focused on further integrating the various functions of the Sunmaster grid connected solar inverter The new Sunmaster IP44 range is the result of this process with a wider application now also suitable for pro
41. astervolt equipment This MasterBus PC Link can be directly connected to a computer serial port Overview of the available software Mastervolt aims to create the broadest package of software for as many products as possible The software available will be conti nuously expanded in the coming years Check our website regularly for the latest updates MasterAdjust software for system components This software can be used to configure monitor and log multiple products The key aspects are One software package for 47 different products Easy to use Windows Explorer like user interface Connect multiple products simultaneously Log multiple products to a data file system logger Connect the Mastervolt products via PC Link article no 21730100 This is an interface between one Mastervolt product and a PC or Laptop or e PC Link with galvanic isolation article no 21730300 This is an interface between one Mastervolt product and a PC or Laptop MasterBus USB interface with galvanic isolation article no 77030100 This is an interface between a MasterBus network which may consist of one or several Mastervolt products All these products should be equipped with MasterBus compatibility System component via PC Link art no 21730100 or 21730300 via MasterBus USB Interface art no 77030100 48 V X BTM III MAC 24 12 20 MAGIC 24 12 20 MAGIC 24 24 20
42. attery charger for use on cloudy days by connecting a small diesel or petrol generator This system guarantees you genuine independence from the electricity company and ensures a high quality power supply AC connection 6 Mastervolt deep cycle batteries for power storage AGM or gel 7 Energy consumers in the house not provided by Mastervolt The best choice for autonomous PV systems Mastervolt offers a wide range of highly efficient sine wave inverters and inverter charger combinations ranging from 250 W to I5 kW In this brochure we have listed our Mass Sine standalone solar inverter Mass Combi inverter charger and the recently upgraded Dakar Combi series All product ranges are designed to operate in harsh environments with high ambient temperatures We also highlight our maintenance free lead batteries and battery chargers which are ideal for quickly and completely charging the batteries using a diesel or petrol generator Mastervolt Combi Combination of functionalities Conversion of battery power to 230 V 50 Hz or 120 V 60 Hz sine wave power Battery charging in case generator or utility power is available Automatic load switching from generator or utility to inverter Programmable all system variations can be selected by MasterAdjust software Energy management by means of advanced monitoring through remote panel and or PC Can be stacked to double the power Ma
43. ch of our products sets a new standard in reliability efficiency and output Practical experience shows the ease of installation and comfort Accessible monitoring functions offer a complete overview of performance Thanks to power of our approach Mastervolt is the beating heart the small dimensions of the Sunmaster it is easy to find a suitable place for installation The carefully considered design of countless solar energy systems with a neatly arranged LCD read out further optimises the user friendliness Clear monitoring functions Mastervolt data control monitoring facilitates extra output for larger grid 6 connected solar systems for example in a housing estate The monitoring guarantees you optimal control Poor performance due for instance to No weak links shading on the roof is quickly registered Permanent data monitoring offers a clear insight into the output per hour day or year Vital functions are controlled with the utmost precision by powerful microprocessors 4 E Meticulously developed control electronics SENT 4 Hs protect the system from malfunctioning Smart temperature controlled cooling fans perform their task in absolute silence Each link in a Mastervolt system makes its own contribution to the overall reliability sustainability and user friendliness Production and control in your own hands As one of the most delicate parts of a PV system the Mastervol
44. dby and night consumption The complete electronics for power conversion fits on a single or double circuit board hence the compact design The cooling requirement is low cooling is effected by temperature controlled and maintenance free ventilators The output voltage only slightly deviates from the pure sine wave shape of the grid THD 396 at nominal load The galvanic isolation in the high frequency transformer between DC input and AC output ensures optimised system safety A high capacity microprocessor precisely regulates all inverter functions measures all output data and monitors the correct functioning of the inverter the connected photovoltaic strings and the power grid The respective data can be shown on an optional display or via the integrated communication interfaces Mastervolt solar inverters comply with international standards Country specific models are supplied with the respective nationally approved anti islanding safety equipment in case of power failure in most countries the QS anti islanding will comply For Germany and Austria we deliver the QS solar inverters as ENS models in full compliance with VDE 0126 1 1 In addition various safety circuits prevent damages or failures caused by incorrect operating conditions The new Sunmaster 44 series the new generation of compact easy to install high performance grid With the new Sunmaster 44 series efficiency and optimum power output
45. e free batteries For larger systems with intensive deep cycle application These batteries are extremely suitable for use in solar and back up power applications Mastervolt batteries can be shipped by air freight non hazardous declaration available on request AGM 12 55 AGM 12 70 AGM 12 90 AGM 12 130 AGM 12 160 AGM 12 225 AGM 12 270 MVG 12 25 MVG 12 55 MVG 12 85 MVG 12 120 MVG 12 140 MVG 12 200 12 V 12 V 12 V 12 V 12 V 12 V 12 V 12 V gel 12 V gel 12 V gel 12 V gel 12 V gel 12 V gel Article no 62000550 62000700 62000900 62001300 62001600 62002250 62002700 64000250 64000550 64000850 64001200 64001400 64002000 Nominal voltage 12 V 12 V 12 V 12 V 12 V 12 V 12 V 12 V 12 V 12 V 12 V 12 V 12 V Capacity C20 55 Ah 70 Ah 90 Ah 130 Ah 160 Ah 225 Ah 270 Ah 25 Ah 55 Ah 85 Ah 120 Ah 140 Ah 200 Ah Dimensions Ixwxh in mm 257 x 132 200 348x 167x178 330 173 212 410x 177x225 485x 170 x242 522 x 240 x 218 522 268 220 164 173 126 253x 133x208 330 171 214 475x178x195 475 210 195 475 x 265 x 216 excl poles Dimensions lxwxh in mm 257x132x207 348 x 167 x 181 330 173 237 410 177 228 485 170x245 522 x 240 x 241 522x268x243 167x 176x126 26 136 230 330 171 236 513x189x223 513x223x223 518 x 274 x 238 incl poles Weight 17 kg 21 5 kg 28 kg 37 kg 42 3 kg 63 5 kg 73 kg 9 6 kg 19 kg 32 6 kg 41 kg 49 kg 70 kg Max installation angle 180 180 180 180 180 180 180 180 180
46. e than 35 compared to fixed installations The photograph extensive data logging system is available as an option doing so we ensure safe operation together with shows recently installed systems in Navarra Spain utilizing Sunmaster solar inverters utility companies and installers of on site photo voltaic systems Mastervolt Master autonomous power systems Electrical power supply is the basis for development A light allowing a book to be read at night The power to operate a refrigerator The benefits of Mastervolt stand alone equipment are seen worldwide from a bamboo house in Africa to a rural school in Central America This is the other specialty of Mastervolt equipment Powering rural locations without a utility grid connection The power of technology development and design Thanks to our range of high tech products Mastervolt has become a leading A brand in the mobile and maritime markets And our equipment is an equally essential part of the fast growing solar market Every product is designed to meet the most stringent requirements Our research and development team constantly seeks new ways to translate tomorrow s technology into improved performance today Every part is designed to play a The power of comfort and accessibility reliable role within an electrical power system And a regular supply of new innovations offers increased Mastervolt equipment has proved its worth in daily practice Ea
47. e there to help you e e e A e 1 e e e e A e e e e e 9 x e e 40 e e 4 A e e e 2 e e 2 o e e e9 e e e e e e e e e o e On time delivery At Mastervolt we take our obligations in terms of meeting after sales guarantees very seriously Our logistical approach is geared towards on time delivery regardless of the size of your project In this way we make sure that our customers can always rely on Mastervolt 2 GR Nr UO ay cs m 2 I i 5 i The power of 24 hour service It is essential that power electronics equipment is completely reliable Mastervolt underlines its commit ment to this principle by offering a worldwide extended warranty on all products The Mastervolt Guarantee Plan Should an unsolvable breakdown occur our experts are ready to assist you 24 hours a day Wherever you are in the world Erla sss eom rm ind mum um um cmm mm a nom Um een 18 7 eal od ptm www mastervolt com Always up to date A vital part of our communication is the extensive web site offering accurate information about products projects and events Our extended support area contains literally all operating manuals technical and commercial documents and software Mastervolt solar inverters offer tailor made power for every configuration large o
48. ee Plan 5 year product warranty worldwide service 48 hour replacement service SAFETY DEVICES General galvanic separation between DC and AC side by means of a class HF transformer Island protection ENS models redundant impedance voltage and frequency window monitoring independent switch off by two pole relay and solid state switch VDE V 0126 1 1 2006 compliant QNS models redundant voltage and frequency window monitoring independent switch off by two pole relay and solid state switch Temperature protection power derating at Tambient gt 40 C switch off at Tindoor gt 90 C DC side protection earth fault detection over voltage detection polarity protection diodes current limitation transients varistor and buffer capacitor overload temperature controlled power derating AC side protection current limitation over and undervoltage over and underfrequency short circuit ceramic fuse Reclosure time MONITORING On the front External communication Monitoring optional transients surge varistors 10 to 300 s model dependent six LEDs for indication of power and system diagnosis two RS485 connections to connect to the QS databus QS display integrated LCD standard for ENS models Data Control Basic software for PC shareware from www mastervolt com e QS PC Link to connect the QS databus to the PC e Data Control Premium Il datalogger and
49. emperature 40 to 60 derating with 596 C Shutdown 80 C heat sink temperature will meet specified tolerances Practical operating temperature 25 C to 40 C ambient temperature 40 to 60 derating with 5 C Shutdown 80 C heat sink temperature may not meet specified tolerances Relative humidity z Max 9596 non condensing protected against humidity and condensing air by conformal coating on both sides of all PCB s Standard and Approvals 120 V model 120 Volt 5 60 Hz 0 00596 See f 2 gt AN SINE WAVE POWER VS U ARAN Mastervolt Guarantee Plan 2 year product warranty worldwide service pure sine wave power galvanic isolation 36 Overview sine wave inverters Mass Sine range lt E Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine 12 500 12 800 12 1200 12 2000 24 800 24 1500 24 2500 24 5000 24 1 0kVA 24 15kVA 48 2500 Article no 230 V 26010510 24010800 24011200 24012000 24020800 24021500 24022500 24095100 24026000 24027000 24042500 Article no 120 V 27010510 n a 25011000 25012000 n a 25021000 25022500 25024000 n a n a n a GENERAL SPECIFICATIONS Nominal battery voltage 2 2 2 2 24 V 24 V 24 V 24 V 24 V 24 V 48 V P30 power Tamb 25 C
50. hat stores electric power in the form of chemical energy When necessary the energy is again released as electric power for DC consumers such as lighting and starter motors A battery consists of several galvanic cells with a voltage of 2 Volt each For a 12 Volt battery six cells are linked in series and fitted inside a single casing To achieve 24 Volt two 12 Volt batteries are linked in series Each cell has positive oxidised lead plates and negative lead metal plates and has an electrolyte con sisting of water and sulphuric acid During discharging the lead oxide on the lead plates is converted into lead The acid content decreases because sulphuric acid is required for this process To recharge the battery an external power source such as a battery charger alternator or solar panel with a voltage of around 2 4 Volt per cell must be connected The lead sulphate will then be converted back into lead and lead oxide and the sulphuric acid content will rise There are limits set for the charge voltage to prevent the release of an excessive amount of hydrogen A charge voltage of more than 2 4 Volt per cell for instance releases a lot of hydrogen gas which can form a highly explosive mixture with the oxygen in the air The upper limit on charge voltage for a 12 Volt battery is 14 4 Volt and the corres ponding value for a 24 Volt battery is 28 8 Volt The relationship between how full a battery is and the specific gravity of the water
51. hould last at least 30 years 5 How long do inverters last You should expect an inverter to function for at least ten years The actual figures depend on the location of the inverter the hotter the temperature the shorter the life span and whether or not regular maintenance is carried out A humid environment will affect the life span as well The ideal place to install an in verter is always in a dry and preferably conditioned environment 6 Is it possible to remotely collect system data There are various options for accessing inverter data See this brochure for more information or ask your supplier for advice 7 Do the panels have to be kept clean The modules are in principle maintenance free and the panels are washed clean by rain It is worth considering cleaning the panels with water once every year 8 What happens if the grid breaks down The solar energy unit will stop returning power to the grid This is necessary to ensure the safety of the system at times when maintenance is being carried out or there is a failure on the grid Please consult your supplier if you wish to keep receiving a 230 Volt current when the grid shuts down Mastervolt has various handy options for providing emergency power 9 Do the panels also provide electricity doing cloudy weather The panels continue to produce energy even when it is cloudy albeit on a smaller scale 10 Can I connect equipment directly to the panels Equi
52. ightlight function and enable of acoustic alarm can be set to customers demands The setting can be secured and locked by the programming lock mode Solar ChargeMaster product specifications SCM N 20 SCM N 40 Article no 131802000 131804000 Charge current 20A 40 A Max DC load 20A 40 A System voltage 12 24 V auto detect 12 24 V auto detect DC grounding negative ground the negative terminals are connected internally No load 4 mA 4 mA Functions LCD display battery status V A charge amp discharge Connections screw terminal Settings load disconnect 3 step charging algorithm Dimensions hxwxd 41 x 140 x 105 41 x 140 x 105 Protection degree enclosure IP20 IP20 Weight 189 gr 189 gr screw terminal 33 34 Overview sine wave inverters AC Master range AC Master AC Master AC Master AC Master 12 200 12 350 24 200 24 350 Article no 230 V continental European socket CEE 7 7 28010200 28010350 28020200 28020350 Article no 230 V IEC I socket 28010201 28010351 28020201 28020351 Article 120 V 60 Hz US socket NEMA 5 15 n a 28510350 n a n a GENERAL SPECIFICATIONS Nominal battery voltage 12 V 12 V 24 V 24 V Nom power Tamb 40 C cos phi I 200 VA 350 VA 200 VA 350 VA Peak load 400 VA 700 VA 400 VA 700 VA Output waveform true sine true sine true sine true sine Max efficiency 90 90 93 89 Output voltage 230 V 5 230 V 5 230 V 5 230
53. imensions hxwxd 476 x 315 x 254 mm 476 x 315 x 254 mm Weight 14 kg 14 kg SOLAR INPUT DC Nominal power to 40 ambient temp 5500 W or 4870 W DC 5500 W or 4870 W DC PV power range 3200 to 7200 Wp 3200 to 7200 Wp Maximum DC power 5900 W 5900 W MPP Tracker dynamic 4 MPP trackers 4 MPP trackers MPP voltage range 100 to 380 V DC 75 to 260 V DC Maximum voltage 450 V DC 325 V DC Nom rated current 4x 7 5 4x IOA 2x I5 A or 2x 20A Start up power power drawn from the solar side 8 W 8 W String connections 4x 2 4x 2 DC connector glands PCB spring terminals 4 mm max or MultiContact connectors GRID OUTPUT AC Voltage 230 V 184 to 265 V depending on the model single or double phase Nom AC power 5200W or 4600 W 5200 W or 4600 W Max AC power 5500W or 4600 W 5500 W or 4600 W Current fused 2x 12 A 2x I2 Frequency 50 Hz 48 to 52 Hz depending on the model Power factor 0 99 0 99 THD 396 rated load in compliance with IEEE p929 Stand by power 0 W DC voltage controlled relay European efficiency 9496 94 596 Maximum efficiency 9596 9696 AC connector gland with PCB spring terminals Limited to 4600 W AC 4870 W DC in case of ENS and one phase feeding two phase feeding with 5200 W AC 5500 W DC possible AS C YEAR eM ARAN Mastervolt Guarant
54. in the energy bill Inverter efficiency A percentage that indicates which proportion of the incoming solar generated electricity is being transformed into useful AC energy Modern high quality inverters have efficiencies higher than 9296 Irradiation The light intensity in a given area Africa for example receives around twice as much sun as the Netherlands Irradiation varies within a country too In the Netherlands for example it varies between 980 kWh m per year in the east to 1070 kWh m on the west coast The average air temperature is also of importance for the annual energy yield of a PV system solar cells perform better at lower temperatures see also Underdimensioning Maximum Power Point Tracker An intelligent voltage regulator that adjusts the operating voltage of the PV array to variations in temperature and cell type A good MPP tracking algorithm draws the maximum solar power from the PV array in all conditions Monocrystalline silicon solar cells Monocrystalline silicon solar cells are cells made from one large monocrystal Thanks to this method of production we have round solar cells each made from one silicon crystal The standard dimensions 10 by 10 cm Monocrystalline silicon solar cells typically have an efficiency of 1696 to 1896 Output of a PV system Solar panels have an efficiency that varies between 896 and 1896 The orientation and shading of the panels and the panel temperature can al
55. ions Two Premium versions are available for different fields of applications Premium Local with incorporated Ethernet network interface Applications Data transmission to PC port directly or via network evaluation via Premium Il PC software Data transmission via internet with the existing ADSL connection evaluation via the Mastervolt portal Premium Remote with integrated analogue modem Applications e Remote data transmission to PC evaluation via Premium Il PC software Remote data transmission via the Mastervolt server evaluation via the Mastervolt portal lik 7 An additional PC be connected to the data logger qm INTERNE CONNECTIVITY The collected data is sent to the internet Data Control Premium 11 Interfaces All inputs and outputs you may wish for are included as standard QS Databus interface for six QS inverters or 30 kW maximum e Analogue input 0 10 for irradiation sensor Mastervolt temperature compensated sensor available as option Digital input for kWh counter Digital output for alarm connection or large size display Integrated power pack Ethernet port Premium II Local Telephone connection for integrated analogue model Premium Remote Data registration A QS data interface connects all inverters with the Premium 11 data registration unit Up to six inverters can be connected The
56. isconnect above 80 C DC polarity protection DC connection is protected MC connectors can be damaged NORMS CE EMC guideline Emission Harmonisation Immunity LV guideline Safety yes EMC 89 336 EEC EN 50081 1 EN 61000 3 2 EN 50082 2 LV 73 23 EEC EN 60950 Products developed for countries where an ENS circuit is not required Fitted with QNS anti islanding as standard UL versions not available 240 V 60 Hz available upon request Mastervolt Guarantee Plan 5 year product warranty worldwide service 48 hour replacement service Front view of the Soladin 600 with clearly visible the intelligent LED human interface 365 76 71 5 L 71 5 Side view Rear view installation bar delivered as standard m Easy to connect kWh meter art no 130500560 25 PC Link with 6 metre cable for system and unit monitoring on the computer art no 130391030 Soladin 600 Wizard software for monitoring on the computer freeware from www mastervolt com 26 Data monitoring Data Control Premium II As a follow up to the successful Premium model for medium sized systems the new Premium offers numerous new functions and an extended operating range Based on the Data Control Professional concept it provides a functional scope previously only found in extremely large systems Professional quality at a reasonable price A unique offer Vers
57. l Frequency Max charge rate adjustable Primary AC consumption full charge Charge voltage 25 C bulk float Battery type settings Second charge output 3 step Temperature sensor for the battery DOUBLE POLE TRANSFER SYSTEM Max current first output Max current shortbreak inverter output Transfer time GENERAL SPECIFICATIONS Harmonic distortion typical Temperature range Grounding Forced air cooling Listings REMOTE CONTROL AND MONITORING 230 V 180 to 265 V 45 to 65 Hz 60 A 14 25 V 1000 VA 4 4 A 14 25 13 25 V 50A 25 A 10 ms 230 V 180 to 265 V 45 to 65 Hz 100 14 25 V 1635 7 2 14 25 13 25 50A 25 A 35 A Q 120 V 10 ms 596 230 V 180 to 265 V 45 to 65 Hz 125 A 14 25 V 2045 VA 8 9 A 14 25 13 25 V 50A 50A 10 ms 596 fully CE and E marking according Automotive Directive 95 54 EG Mass Combi 12 4000 200 36014005 37014005 I2 V 10 to 15 V 3750 VA 16 5 7500 VA 32A no yes 230 V 5 true sine wave 9296 9 W W 40 150 460 5 x 318 x 266 21 kg 230 V 180 to 265 V 45 to 65 Hz 200 14 25 V 3270 14 4 A 28 5 26 5 V 50A 25 A 35 A Q 120 V 10 ms Mass Combi 24 1200 35 36021205 n a 24 V 20 to 31 V 1200 VA 5 3 2400 VA 10 5 A no yes 230 V 5 true sine wave 9296 9 W 0 5 W 40 150 VA 371 x 318x 143 7 8 kg 230 V 180 to 265 V 45 to 65
58. m power 180 to 480 V DC 180 to 480 V DC Maximum voltage 600 V DC 600 V DC Number of inputs 3 3 Rated current 3x I5 A 3x 30A MPP tracker DC connectors GRID OUTPUT AC 3 MPP trackers with 99 996 MPP efficiency Fraunhofer algorithm 6 Multi Contact Il connectors 6 Multi Contact connectors Voltage Power Nominal current 230 V AC three phase 230 V AC three phase 10 000 W nominal 10 500 W maximum 15 000 W nominal 15 750 W maximum 3x I5 A 3x 22 Frequency Power factor Harmonic distortion 50 Hz models 48 to 52 Hz programmable 60 Hz models 57 to 63 Hz programmable gt 0 99 at full power gt 0 99 at full power THD lt 3 at full power THD lt 3 at full power Stand by power Efficiency AC connector lt 5W lt 5W EU 95 Unom maximum 96 EU 95 Unom maximum 96 AC and DC glands on detachable plate in bottom of connection compartment Power modules supplied with 3x 4 mm cable DIN rail connection equipment fuses terminal blocks etc not included Fuse SAFETY DEVICES General Internal PCB fuse in power modules Internal PCB fuse in power modules galvanic separation between DC and AC side by means of class HF transformers Island protection Safety devices DC side Safety devices AC side 2 An AC fault in any of the phases will disable all three power modules 5 Redundant voltage and frequency window monitoring QNS Independent cut off by means of 2
59. ontrol for reducing shore power consumption Masterlink MICC n a yes yes yes n a yes yes yes n a n a art no 70403105 Battery consumption meter 12 24 V DC with LCD readout and remote control for Mass Sine inverter and battery charger or Mass Combi System Manager MICC n a n a yes yes n a yes yes yes n a n a art no 70400115 Battery consumption meter 12 24 V DC with LCD readout and LED bar Comprehensive remote control for Mass Sine inverter and Mass charger MasterAdjust communication connection QORS232 QRS232 QRS232 QRS232 QRS232 QRS232 QRS232 RS485 QRS232 QRS232 RS485 QRS232 RS485 Universal connection cables for the remote controls 6 metre art no 6502001030 10 metre art no 6502100100 15 metre art no 6502100150 Autoranging operates on 120 V and 230 V charge current reduction at 120 V 20 to 3096 T connection necessary to connect both temperature sensor and remote CC art no 21730200 ALIN Galvanic isolation RS485 communication port yen 3STEP 7 Mastervolt Guarantee Plan 2 year product warranty worldwide service Mastervolt 3 stepO charging method galvanic isolation 42 Overview Mastervolt maintenance free batteries 2 V AGM batteries sealed batteries with glass fibre technique For cyclic application 2 V gel batteries sealed batteries with electrolyte in a gel substance For intensive cyclic application 2 V gel batteries extremely durable absolutely maintenanc
60. ovides monitoring read outs and alarm warnings via the internet During the day the data logger extracts information on power output directly from up to 20 Sunmaster inverters via the QS data port This eliminates the need for external kWh meters Overnight the collected data is sent to a web page from which it can later be accessed from anywhere in the world using a log in code Exceptionally accurate weather prediction data is used to assess the output of the PV system An important advantage of the system is the link from the local monitoring to the weather registration of Meteomedia in Germany An external reference cell is not required Should the Sunmaster inverters report a system fault or the solar yield not conform to the expected specified value an alarm routine of the Safer Sun Programme is activated According to the settings an alarm is triggered on site at the device itself or a warning message is sent by email fax or SMS This superior monitoring method ensures a high availability of the recording device which in turn enables a large number of systems to be monitored Online visualising of energy production during one day based on current online weather data by Safer Sun TERNE CONNECTIVITY Data Control Pro The collected data is sent to the internet Data Control Pro specifications Data logger Data Control Pro Integrated modem analogue ISDN GSM Art no 1303 96 2xx xx 00 xx
61. pment cannot be connected directly to a grid connected solar installation an electricity grid is always necessary AC consumers can be directly connected to grid independent sine wave inverters in island systems Is there any difference in the electricity coming from a solar system No the current is the same 12 Can my solar installation attract lightning There is no record of this ever occurring The chance of lightning striking is equal regardless of whether or not you have a solar system 13 Can a solar installation cause damage to my household equipment No this is not possible The inverter functions as a sort of filter between the grid and the PV system and complies with the highest suppression standards 14 What happens to the electricity that has been generated but not used The electricity generated by the solar panels is first consumed by the various equipment in the building concerned Any excess power produced is returned to the public grid Make sure you request from your energy supplier a meter that turns backwards if one is not already installed 53 54 Technical Notes Cover photo George Burggraaff MASTERVOLT INTERNATIONAL BV MASTERVOLT ADRIA MASTERVOLT AUSTRALIA MASTERVOLT BENELUX MASTERVOLT CHINA MASTERVOLT DENMARK MASTERVOLT FINLAND MASTERVOLT FRANCE SARL MASTERVOLT GMBH MASTERVOLT INC MASTERVOLT ITALIA SRL MASTERVOLT NEW ZEALAND
62. pole relay and solid state switch ENS according to VDE 0126 1 1 2006 DC to earth isolation resistance monitoring DC over voltage detection LED warning and switch off DC inverse polarity protection diodes DC current limiting by up shifting operating voltage transients varistors and buffer capacitor overload power limiting and temperature controlled power derating AC current limiting DC current injection protection short circuit ceramic fuse transients surge up to 4 kV varistors Reclosure time wait 10 to 300 s model dependant after AC grid fault SYSTEM INFORMATION DIAGNOSTICS COMMUNICATION User interface 6 status LED s on each power module External communication 2 surge protected RS485 connections 10 XL units can be connected to Data Control Pro datalogger REGULATIONS AND DIRECTIVES CE Conformity yes EMC Directive EMC 89 336 EEG Emmision EN 55022 Harmonics EN 61000 3 2 IEEE 1547 Dips variations flicker EN 61000 4 11 EN 61000 3 3 Immunity EN 61000 6 2 LV directive 73 23 EEG Electrical safety EN 60950 Anti islanding VDE 0126 1 1 2006 24 Soladin 600 amp Windmaster 500 product specifications Article no Soladin 600 solar energy 1 30000600 Italy 130000610 Spain 130000620 UK 130000630 Article no Windmaster 500 wind energy 140000500 GENERAL Work temperature storage temperature 20 C to 40 C 20 C
63. r small Leading edge technology ensures that the energy supplied by solar cells is of a consistently high quality and optimally efficient And our SysCalc calculation tool means it couldn t be easier to choose the right Mastervolt inverter for your needs Solar power conversion amp monitoring solutions Grid connected applications Introduction to grid connected PV systems 12 13 New Sunmaster 44 series 14 15 Power range 1200 7000 Wp IP44 series 16 18 Standard data monitoring 19 Power range 3200 7200 Wp IP23 series 20 21 New Sunmaster XL series for high power PV systems 22 23 Power range 100 600 Wp Soladin series 24 25 Data monitoring 2o t a a 26 29 Autonomous systems Introduction to autonomous PV systems 30 31 Solar ChargeMaster series 32 33 Sine wave inverters 200 15 34 37 Sine wave inverter charger combinations 38 39 Automatic battery chargers 40 41 Maintenance free batteries 42 45 Battery monitoring panels 46 47 Mastervolt communication software 48 49 Background information Technical definitions 50 51 System example grid connected 52 Frequently asked questions on PV systems 53 Inverters for grid connection The most effective and popul
64. rgy yield and total operating hours since commissioning Voltage current and power output of the connected solar modules Voltage current frequency and impedance of the 230 V mains Current internal temperature of the inverter Power currently supplied to the mains Serial number communication address inverter number Current status and fault messages e g overvoltage ENS switch off over temperature The cause of any failure can be easily determined and the fault remedied with the additional operating data With Premium 11 6 WR 30 kW 6WR 30 kW yes yes yes yes yes yes option Remote installers can dial in via an internet or modem connection and assess in advance what has to be done Evaluation Data inquiry and evaluation is via a PC The connection to the Data Control Premium Local is optionally established via direct or network connection The Premium Remote can be optionally evaluated via the data telecommunication modem connection or worldwide via the Mastervolt Internet Portal Five years free access to the Mastervolt Internet Portal is included in the price There is only an initial charge payable for setting up your system in the portal Monitoring alarm function Email fax SMS visual acoustic optional The connected inverters are automatically detected 27 Internet data monitoring Data Control Pro The Data Control Professional data logger pr
65. s Galvanic isolation Class Il Class Il Class Il Class Il 30 Dimensions hxwxd 471 x 356 x 145 mm 545 x 356 x 145 mm 545 x 356 x 145 mm 725 x 356 x 145 mm 20 Weight 6 kg kg kg 15 kg SOLAR INPUT DIRECT CURRENT 0 500 1000 1500 2000 Nominal power 1700 W DC 2750 W DC 2750 W DC 5250 W DC AC output rating Higher yield due to HF technology PV power range 1200 to 2100 Wp 2000 to 3600 Wp 2000 to 3600 Wp 4500 to 7000 Wp especially at partial load Maximum output 1800 W 2950 W 2950 W 5600 W Mastervolt inverter MPP tracker MPP tracker 2 MPP trackers 2 MPP trackers 2 MPP trackers o MPP voltage range 100 to 380 V DC 100 to 380 V DC 75 to 260 V DC 180 to 480 V DC Maximum voltage 450 V DC 450 V DC 325 V DC 600 V DC Nominal rated current 7 5 A 2x 7 5 2x l0 A 2x ISA or Ix 15 or Ix 20A or Ix 30A Start up power 2W 4 W 4 W 8 W String connections 2x 2x 2x DC connector MultiContact connectors or glands spring terminals 4 mm GRID OUTPUT INVERTER Voltage 0 000 230 V AC 184 to 265 V depending on model single phase Nominal output at 45 C 1600 W 2600 W 2600 W 5000 W Maximum output 1725 W 2750 2750 5250 W Maximum current 8A 25 Frequency 2 50 Hz 48 to 52 Hz depending model
66. so affect the eventual output Photovoltaic systems Also known as PV systems The word Photovoltaic is a combination of the Greek word for light and the name of the physicist Alessandro Volta It denotes the direct conversion of sunlight into energy by means of solar cells Polycrystalline multicristalline silicon solar cells Solar cells made up of multiple silicon crystals As the crystal edges can impede the electron flow multicrystalline silicon solar cells are usually less efficient than the monocrystalline equivalent The output is usually between 14 and 16 Most poly crystalline silicon solar cells are blue in colour Power loss Power loss can be caused by the location and orientation of the solar cells and other factors such as Placement losses caused by non ideal orientation to the sun Shading losses Even partial shading of cells or modules causes relatively high losses Panel losses caused by the electrical resistance of inter connections inside the solar module and losses introduced by series connection of the cells see String Inverter losses Solar energy converted to heat and therefore not fed back into the grid Cable losses caused by the electrical resistance of the wiring Temperature losses solar voltage and power decreases with 0 5 per degree Celsius This may lead to relatively large losses at full irradiance see also Underdimensioning Shading Shading of solar cells may lead to
67. ss Combi inverter charger models Features Switch mode technology Mass models Extremely efficient and minimal heat loss Exceptionally quiet Easy to mount in a central IP54 or IP65 cabinet High peak power 20096 offered by a build in soft start to handle inductive loads smoothly Pure sine wave output under all load circumstances Power factor corrected battery charger accepts almost any type of generator Mass Combi models 3 Step charge method ensures the fastest and most complete recharge 3l Complete range Output capacity ranging from 250 W to 15 kW Available for both 230 V 50 Hz and 120 V 60 Hz Available in 12 24 and 48 V DC Perfectly compatible with existing systems Pure sine wave output protection of your appliances and trouble free operation Simple and extremely safe installation Available as complete system including batteries 32 Mastervolt advanced solar charge controller Mastervolt is pleased to announce its latest product release the Solar ChargeMaster range offering a 20 and a 40 A solar charge controller This range has been developed using Mastervolt s 16 years of excellent expertise in the field of battery charging technologies The Solar ChargeMaster was designed specifically to meet the needs of rural solar electrification and small PV systems for tele com remote cabins weekend homes and RV caravans and boats The new product range is a welcome addition to
68. stervolt communication modules offer a flexible reliable and user friendly possibility to permanently monitor your grid connected photovoltaic system also from a remote location This ensures a constant overview of the solar power yield and all important system data When a value is no longer within the specified limits you can quickly take corrective actions External energy counters are not required The modules Data Control Basic Data Control Premium and Data Control Pro offer different functional possibilities extending from the display of the current systems data on the optional display to the web based remote monitoring and visualisation Data Control Basic standard for the Sunmaster range Every Sunmaster model comes as standard with an integrated RS485 communication interface and a ten day power output memory This makes the entire PV system interactive with the option of reading the most essential information using your PC or laptop All that is required to connect the Sunmaster with your computer is a communication cable and PC link adapter plug m 3 15 45 eee ECT T T T FE i I P L Tr Basic monitoring via the PC Data Control Basic Software PC Link optional The software for reading out the data under Microsoft Windows is available free of charge in the Download amp Support section of our website under www mastervolt com The Data Control
69. t can be discharged more often and to a greater extent approximately 300 full cycles This kind of battery is highly appropriate for the combined function of starter service battery Mastervolt recommends to use maintenance free deep cycle AGM or gel batteries see previous pages lt is important to charge the batteries according to the appropriate charge characteristic Sealed traction battery The traction battery This type of battery has even fewer but very thick flat or cylin drical plates It can therefore be discharged many times and fairly completely 1000 full cycles This is why wet traction batteries are often used in forklifts and industrial grade cleaning machines But wet traction batteries require a special charge method Because these batteries are mostly tall they are sensitive to the accumulation of sulphuric acid at the bottom of the battery container This phenomenon is called stratification and occurs because sulphuric acid is denser than water Acid content increases in the lower part of the battery locally intensifying plate corrosion and decreases in the upper part reducing capacity The battery is discharged unevenly significantly reducing the life span In order to spread out the acid evenly again the battery has to be purposefully overloaded using excessive voltage This generates a large amount of hydrogen gas which will form a dangerous mixture with oxygen in the air The voltage required
70. t inverter or combi is responsible for numerous vital functions These include accurate converting of DC array voltage to AC power providing information on DC and AC output as well as volts and amps and system security Manufactured according to ISO 9001 2000 Mastervolt solar inverters meet the highest standards Every product and component is thoroughly examined with an ICT computerised test before delivery Education and training In addition to the quality of our products Mastervolt s reputation for reliability is also due to a service network that offers fast local support Thanks to a continuous education and training programme our dealers are always up to speed with the latest developments and fully trained to safely install Mastervolt equipment Our solar specialists are dedicated to this sector and will be pleased to offer you advice and support on any project i PACTE TAER E INTEL E EDATE a Tee LLB X m ia MTS Ka ETT A 2 i The sustainable power of worldwide service and support Mastervolt is committed to sustainable relationships as well as sustainable power Nowhere is this more apparent than in our service and support network which is spread across more than 50 countries Setting up a new solar energy project Extending or adapting an existing system An experienced Mastervolt specialist and system adviser will b
71. tected outdoor use user friendliness smarter connections and a stunning read out facility This is one of my best designs so far Industrial Designer Rob van Opdorp Menu selection key Attractive LCD display measurements actual with backlight and clear day total and graphics for optimal system information readability Source selection key data measurements Failure LED enabling a fast and secure trouble shooting Actual reading key W V Hz kWh etc Selection key historical data All weather proof poly carbonate UV resistant MultiContact DC string connections MC2 Y adapter set available upon request art no 130362900 Integrated heavy duty DC switch Standard for all ENS versions optional for remaining models Gland for communication connection cable QS databus Easy acces terminal Connection connection for AC grid cable compartment Gland for AC grid connection cable HF transformer technology combines ideal with all PV modules mono poly and multi cristalline thin film and amorphous Extremely compact only 15 cm deep Smart cooling concept enables 100 output Light weight power even at high and easy to 40 ambient install the temperatures XS6500 only weighs 18 kg solar solar 2 AC grid Sunmaster 44 product specifications a L QS2000 IP4
72. to 70 C Relative humidity max 9596 not condensating Protection degree safety class IP23 class Il Dimensions hxwxd 365 x 143 x 76 mm Weight 2 kg Casing plastic ABS SOLAR INPUT DC Power 535 W nominal 600 W maximum PV power 160 to 700 Wp MPP voltage 40 to 125 V DC Maximum voltage 155 V DC Nom rated current 8A Starting up power W DC 40 V DC DC connection MultiContact 4 mm GRID OUTPUT AC sun amp Wind applications Voltage 230 V 184 to 265 V programmable Maximum power 2 25 A Fuse 3 15 slow Frequency 50 Hz 49 8 to 50 2 Hz Cos phi 0 99 Zero load 0 05 W AC DIMENSIONS IN MM ACCESSORIES European output max output 9196 9396 AC connection Euro socket READ OUT FUNCTION Indicator two LEDs yellow and red Correct working flashes yellow speed of flashing is in relation to the power generated Malfunction grid or inverter red 6 different flashing codes PROTECTIONS Island protection monitoring of voltage and frequency frame disconnects within 100 ms ENS not available Protection of peak capacity automatic control dependent on the temperature of the converter by raising the Vmpp It is impossible to damage the converter with too much power Temperature protection reducing the power in case of a higher temperature of the converter will d