SecureSync Version 4.8.9 Release Notes

image

Contents

1. Software update Release Notes SecureSync SecureSync Version 4 8 9 Release Notes Release Notes for SecureSync System software updates up to and including Version 4 8 9 Spectracom releases software updates for SecureSync on a regular basis in order to improve features enhance existing functionality apply security updates and software fixes This document captures legacy release notes for all 4 x SecureSync software updates Newer updates are captured in a separate document please refer to Links to download SecureSync software and user manual updates Table of Contents New features 5 2506 dend Suadacadvasndsesyasiepastsssdeed a RA EREE E E O RANT EEEE RRR EEEE E EES O ERARE 2 SoftWare enhancements sc assenaaassasempansoneneunshcezaancesecesiraanaasaatenedtanthaatiandsvsauaseasauustacstaushaateanebarstastaciuastonsinesasaee 12 Determining the version of software currently tis talled gsccssacess ssucesscadavyssnadacaesvaccusesieacisivvacassessaeeedeeeaeerss 25 Links to download SecureSync software and user manual updates nnssssseessesseesseesseeeessetsseessessseesssessseesseese 26 Spectracom Tech SUpport eits minesine e a ei E a eea E aa eaa 21 www spectracomcorp com 1 SecureSync Release Notes 4 x spectracom New features Version 4 8 9 System features e Extended the SNMPv3 EngineID field to support more than 32 characters o EngineID field now supports up to 50 characters e The servget and se
2. Scale selection of either GPS or TAI time scale as configured in the Setup Time Management page of the browser Moved the oscillator DAC messages from the Timing log to the Oscillator log Also removed redundant frequency error log messages from the Timing log which were also present in the Oscillator log as well Added a display of the selected Local Clock name to the Status Outputs IRIG as well as the Status Inputs IRIG web browser pages o If no local clock is selected for IRIG Input Output the Local Clock field will display NONE instead Lengthened the Time Scale data fields in the ASCII RS 232 and RS 485 and NENA Option Card s Status inputs configurations in order to show the entire name of the selection Fixed a typographical error on a note that is displayed in the Security tab of the Tools Users page of the browser Version 4 8 2 Software changes incorporated for potential security vulnerabilities Applied changes to the ssl conf configuration file to mitigate CVE 2011 3389 SSLv3 0 TLSv1 0 Protocol Weak CBC Mode Other software enhancements Added protection against an NTP input reference from scheduling a Leap Second pending too early o A Leap second pending that is detected by NTP input earlier than one month before a leap second is to be asserted aren t scheduled until no earlier than the first day of either the following June or following Dece
3. TFOM gt 7 and NavConv was NEVER being cleared Now if SecureSync exits sync NavConc is 1 and if not in Sync or Holdover NavConf is 0 5101 messages are now only outputted when TFOM lt 7 and message is enabled or connected Also TFOM is set to 9 if SecureSync is not in sync and is the actual value when SecureSync is in sync Models 1204 14 SAASM GPS Receiver Option Cards if installed e Resolved an issue which was preventing the zeroize CLI command from working System enhancements e Option 04 Rubidium Oscillator when installed Shortened Rubidium oscillator sync time after each subsequent boot up o After a sync threshold of 3 5 hours the currently calculated frequency error correction is saved when entering holdover in addition to the 24 hour save e Option 04 Rubidium Oscillator when installed Fixed an issue that could cause a TFOM value of 1 to be reported at system boot up e Fixed a minor issue with Low Phase Noise LPN Rubidium oscillator tracking while in Holdover mode no input references present and valid e Network Access table is now properly backed up and restored when using either the Save Configuration or Restore Configuration processes Tools gt Upgrade Backup page of the browser Configuration tab e IPv6 main default gateway can now be configured e SSH Rate limiting fix o Resolved an issue of login counts not being cleared e Resolved an issue with the User Defined Minor and M
4. card to be controlled by software Version 4 4 0 www spectracomcorp com 9 SecureSync Release Notes 4 x spectracom e Added Demo support for Simulcast features option cards e Added Demo support for new SAASM GPS receiver option card e Added Demo support for new PTP input output option card e Added several new 30 minute and 15 minute Time Zone Offsets to Setup Local Clock page o Previously Local Clocks could only be configured for whole hour UTC offsets Added several new partial hour Time Zone Offset values to select from in the Manual UTC Offset drop down box for countries outside of the US e clean and cleanhalt commands can now be issued via the front panel SERIAL port o These two commands allow SecureSync to be either reset to factory default values and then power cycled clean or to be reset to factory default values and then halted for equipment shutdown cleanhalt using the front panel RS 232 port Version 4 3 1 e An optional user defined login banner was added o An optional banner can be configured for display on the login page each time a user attempts to login to SecureSync The user defined banner is configured in the Network General Setup page of the browser in the Banner tab An example of a login banner that can be displayed if desired is a phrase that states A user must be authorized to access this appliance Just knowing the login password is not suffic
5. installed e Added Forced Holdover mode Replaces Alternate Master mode o Applicable only to PTP Slave mode not PTP Master mode o Enabling this mode suspends the phase and frequency corrections of the PTP clock System features e Added a feature to allow the system PPS to restart tracking of the 1PPS input reference o Setup gt Disciplining page of the web browser This new feature can be used to allow rapid alignment of the system 1PPS with an input 1PPS reference which is useful in cases where either the system 1PPS has drifted far from the reference because the reference has been lost for an extended period of time and is then restored or if the reference 1PPS has changed by a large offset Otherwise the System PPS is very slowly slewed into alignment with the 1PPS reference e Added a feature to allow the user to set an offset of 0 seconds when configuring a leap second o Selecting 0 will clear the previously configured leap second e Added a new CLI command called syncstate which will return the synchronization status of the system o Returns the value of Sync Holdover or Free Run e Added a feature to allow the user to disable the SecureSync s position information from being displayed on the front panel LCD Setup gt Front panel page e Updated the Spectracom organization and address information in the Global MIB file e Added a feature to display the system hostname and Sp
6. minor issue that caused relay configuration information to persist if this Option Card had been removed Models 1204 02 and 1204 03 ASCII Option Cards if installed e Fixed an ASCII output RS 232 interfaces simultaneously e Fixed an issue that prevented generation of emulated SAASM GPS messages on multiple e Fixed a defect that required an NMEA 0183 GGA message to have HDOP gt 1 0 in order to be used for synchronization After this fix HDOP gt 0 0 is required for synchronization System enhancements www spectracomcorp com 16 SecureSync Release Notes 4 x spectracom e Fixed a defect that caused changes to the syslog configuration to not be recorded in the Journal log e Improved the descriptive text of several of the Web browser pages e Fixed a defect that could cause the quick phase alignment of the system 1PPS to the reference to continue for an indefinite period of time now limited to 60 seconds e Fixed a defect that caused the System Time to be offset by approximately 500ms after a power cycle e Fixed a defect that caused the domain name entry on the network interface configuration page to persist after being deleted e Fixed a defect that caused the configuration archive file to be deleted following a configuration restoration e Fixed a defect that prevented the names of local clocks from using non alpha numeric characters o The local clock names must now consist of a single word made up of t
7. second values provided in the input data stream Resolved a web browser display issue when no GPS receiver is installed in the appliance o Error messages were being asserted in the System log if displaying certain web pages when the 30 second screen refresh occurs www spectracomcorp com 22 SecureSync Release Notes 4 x spectracom e Updated the ICD153 ASCII output from the ASCII time code Option Cards Models 1204 02 and 1204 04 to provide better interoperability with a SINCGARS radio system e Daylight Saving Time DST in user configurable Local System Clocks can now be configured to occur in the last week of the month if necessary e Added rotation of NTP statistics logs NTP peerstats clockstats and loopstats Version 4 4 0 e Improved NTP performance by making NTP a higher priority o Due to the priority settings of NTP the NTP output was exhibiting higher jitter measurements as compared with other NTP servers on the same network as viewed with an NTPQ peers command Increased the priority of NTP for improved performance of NTP e If an ASCII RS 485 or RS 232 option card is installed in SecureSync this update fixes an issue that was causing SecureSync to lock up if an ASCII reference was applied to the input of this option card the ASCII option cards outputs operated normally e Changed the Reference Status table indications Status Time and Frequency page of the web browser o This status tab
8. server is configured for AC input only DC input power status is no longer displayed on this page of the browser Version 4 8 0 Software package version updates for potential vulnerabilities Apache web server software updated to version 2 2 21 to address security vulnerabilities in earlier versions OpenSSL software updated to version 1 0 0e to address security vulnerabilities in earlier versions OpenSSH software updated to version 5 9p1 to address security vulnerabilities in earlier versions Other software enhancements Fixed a defect in setting local clocks in ASCII EBU IRIG Display and HaveQuick components which resulted in a local clock being set on a different instance than the one selected Fixed a minor issue that caused the Web browser to stop responding after configuring SNMP o If the User Community field in the Notifications tab was left blank when the Submit button was pressed the web browser was no longer accessible until a clean command was performed Fixed a limitation that wouldn t allow creation of new usernames that were a sub string of another username that already existed o Examples include admin a sub string of the spadmin account and user a sub string of spuser account Fixed a defect that didn t allow the setting of IPv6 addresses in the web browser Fixed a defect that caused the HTTPS certificate request to contain truncated fields Network HTTPS SS
9. C time e Corrected an issue with displaying changing the SNMP notification Port in the Network SNMP Setup page of the web browser Notifications tab e The web browser login banner if one has been created Security certificates and public private HTTPS keys are now preserved through a clean command e Fixed an issue that could periodically prevent the NTP statistics graphs from being displayed in the web browser www spectracomcorp com 21 SecureSync Release Notes 4 x spectracom Version 4 6 0 e Improved DNS server functionality o DNS servers are now managed per each network interface EthO Eth1 Eth2 and Eth3 o The web browser now supports two DNS servers per network interface Fixed a minor issue that prevented certain unique network IP address values from being able to be configured via the front panel LCD but could still be successfully configured via the web browser Applicable to the PTP Option Card module Model 1204 12 Added a Peer Delay feature for use with Transparent PTP clocks e CLI Clean command no longer responds with additional jibberish when command is issued Version 4 5 1 e Resolved a limitation of not being able to exceed a total of 12 IRIG outputs from SecureSync via installed Option Cards O Increased the total number of available IRIG outputs that can be supplied via multiple installed Option Cards to 24 this value is based on all s
10. H Setup page of the web browser HTTPS tab Applicable to the PTP Option Card only Added P2P Peer to Peer mode to the Delay Mechanism drop down field in the PTP Protocol tab o Previous versions of software only allowed E2E End to End Delay mechanism to be selected The Clean command now restores the GPS receiver to factory default mode www spectracomcorp com 19 SecureSync Release Notes 4 x spectracom o Mobile or Single Satellite modes are now returned to factory default Stationary mode upon a clean command being issued e Fixed an issue where NTP wasn t reporting stratum 16 while NTP was out of sync e Fixed an issue that caused the reported phase error to not degrade when all input references were removed on SecureSyncs that are equipped with Rubidium oscillators Status Time and Frequency page of the browser e A User is now logged out automatically after clearing the unit s configurations as performed in the Tools Upgrade Backup page of the browser Configuration tab e LDAP certificates are now preserved across software updates and also deleted when clearing the unit s configuration as performed in the Tools Upgrade Backup page of the browser Configuration tab e Fixed a defect that didn t allow leap second information from the timing system to be propagated by NTP e Removed Web browser configuration for notifications SNMP traps and email alerts that are not curr
11. Refer to Figure 1 Actions Indication of the current software version installed Figure 1 Software revision reported in the Tools gt Upgrade Backup Page B Using the Classic Interface Software versions 5 0 2 and below Log in to the unit s web browser user interface At the top of the page click on Tools In this drop down click on Versions The System Version table on this page will contain a field stating Archive version The number next to this is the current Archive software version Refer to Figure 2 SYSTEM VERSION ee A Spectiavem SasinuSyes Version 4 00 z E an OW VIAA PPSA M Voi OC 10 VAOR POA 1h vaine DE FI VIO PPAA 90 yone OCHA VE FPGA OS veio DE FF VENIT FPA et vooo OC FE VOII FPGA 90 vorne OL FE VOLE PPRA OO viise FPGA AND FIRMWARE VERSION im sm Aa 1o Indication of the current Archive software version installed Figure 2 Archive software revision reported in the Tools gt Versions Page www spectracomcorp com 25 SecureSync Release Notes 4 x spectracom Links to download SecureSync software and user manual updates Download SecureSync software updates The SecureSync software update can be downloaded from the Spectracom website To obtain the SecureSync software update file please visit http www spectracomcorp com Support HowCanWeHelpY ou Software tabid 61 Default aspx SecureS ync SecureSync user ma
12. Sync as a Stratum 2 time server o The NTP Servers table located on the Network NTP Setup page NTP Servers tab contains two new checkboxes One checkbox allows the System Time references to be selected de selected as an input to NTP The other checkbox allows the System Time 1PPS to be selected deselected as an input to NTP Prior to having these checkboxes available NTP performance could be affected by either poor System Time reference inputs or when using SecureSync as a dedicated Stratum 2 time server e Implemented Mobile mode for GPS reception o The GPS receiver when installed can now be configured to operate in a mobile environment such as on an airplane ship boat truck etc www spectracomcorp com 11 SecureSync Release Notes 4 x spectracom Software enhancements Version 4 8 9 Option Card enhancements All Models of 1PPS Output Option Cards if installed e SecureSync now allows more than 12 1PPS outputs All 6 Option Bays containing 1PPS Output Option Cards is now supported Model 1204 06 Gigabit Option Card if installed e Upgraded the network processor driver to a newer version to help prevent potential of network packets being dropped Also disabled network flow control Models 1204 02 and 1204 04 ASCII Output Option Cards if installed e Fixed minor issues with 5040 and 5101 ASCII Output messages o Fixed a defect in which TFOM would display incorrect values 5101 messages would be output when
13. This change allows 15 logins per minute for each Ethernet connection type e Added capability to enable rotation of the LCD content display through all available content screens o Rotation duration is configurable from 1 30 seconds e Added new ppsctrl CLI interface command o This new command provides the ability to enable disable the 1PPS outputs in the system using a telnet ssh connection in lieu if of using the web browser e Added a report of the selected PPS reference to the CLI status command message when the SecureSync is synced to another NTP server on the network e Added commented set options to email configuration file to show how to send the username in a notification email as something other than root followed by domain name O Capability to edit this email alert value previously existed in all earlier versions of software But the example email config file did not provide information on changing this value www spectracomcorp com 3 SecureSync Release Notes 4 x spectracom e Added ability to restore the factory default configuration during a software update e Added support for new Fiber Optic 1PPS and IRIG Option Cards o Model 1204 1E 4 IRIG Output Fiber Optic o Model 1204 27 2 IRIG Input 1 IRIG Output Fiber Optic o Model 1204 2A 1 PPS Input 2 PPS Output Fiber Optic o Model 1204 2B 4 PPS Output Fiber Optic Version 4 8 6 Option Card features Model 1204 12 PTP Option Card if
14. ajor GPS Threshold alarms counters www spectracomcorp com 12 SecureSync Release Notes 4 x spectracom o The elapsed count down timers weren t resetting if the GPS receiver started tracking greater than the number of specified satellites again before the counter expired e Text of ss tar was erroneously being displayed while performing a software upgrade using the web browser e The Services controller daemon is now restarted whenever a network service is enabled or disabled e Resolved an issue with the Version field in the Network gt SNMP Setup page of the web browser Notifications tab displaying a null when V3 is selected e Fixed an issue when using ASCII input and external 1PPS input as the selected Input References o Resolved an issue where external 1PPS input validity could be affected if a user was to detach the 1PPS input cable or switches the Data Format in the ASCII time code generator Version 4 8 8 Option Card enhancements Model 1204 02 ASCII RS 232 Option Card if installed e Applicable to ASCII 5101 Input messages only improved processing of Day of Year DOY information Model 1204 12 PTP Option Card if installed e PTP configuration changes are now being recorded in the Journal log e Sync E was removed from the web browser e Fixed an issue where only 4 installed PTP Option Cards were supported o Slots 5 and 6 weren t able to support PTP Option Card
15. another user to be automatically exited out of the web browser www spectracomcorp com 20 SecureSync Release Notes 4 x spectracom e NTP will now automatically restart if a System Time change greater than 1000 seconds occurs o If System Time which is synced by the SecureSync s input references and is also the time reference that NTP syncs with happens to be significantly changed which may occur when either manually setting the System Time or if the system switches from one selected input reference to another reference that is not aligned with the same time as the previously selected reference and this time change is greater than 1000 seconds while NTP is running the NTP sanity check will fail This will cause NTP to automatically stop restart itself in order to compensate for the necessary large time correction Otherwise if the System Time happens to change by less than 1000 seconds NTP will slowly slew itself to the new time instead of restarting itself e Fixed a minor web browser display issue associated with the Prefer Timing System Reference and the Enable Timing System 1PPS Reference check boxes Network NTP Setup page of the browser NTP servers tab o Though both of these fields are enabled by default the check boxes for these two fields were indicating they weren t selected in the background these functionalities were being enabled but the two checkboxes were just indicating othe
16. ctually were These large frequency error calculations were intermittently asserting the Frequency Error alarm O An intermittent 1PPS reference input to the Rubidium oscillator was causing large phase error measurements e The ASCII timecode Data Format 09 output Available with an RS 232 or RS 485 ASCII time code Option Module installed was not using the correct Quality indicators when SecureSync was not synchronized to any input references Data Format 09 was selecting the Format 02 Quality indicators instead of the Format 09 Quality indicators a space when in sync or the letters A B C or D were being inserted for loss of sync instead of the correct indication of a space when in sync or the characters of an or being inserted for loss of sync Version 4 2 1 e Static network settings are not able to be saved after a Clean of the configuration files has occurred O After the configurations are cleaned reset back to the factory default values either at the factory prior to initial shipment or in the field using the web browser static network settings are not able to be configured and retained Version 4 1 0 e Added the ability to select a Local Clock via the web browser in order to offset the LED time display for local time O Local Clock allows the output time to be offset for local Time Zone and DST Rules Version 4 0 0 allowed a Local Clock for the front panel LED tim
17. e assigned to SecureSync e Increased the maximum number of remote Syslog servers from 5 to 8 Version 4 8 4 System features e Users can now save and re save overwrite existing the configuration archive file via the web browser o Performing a Restore configuration will delete the configuration archive file e Added fields in the Status NTP page of the browser to display the NTP Leap Indicator LI Bits for each configured NTP server NTP peer and reference clock drivers o The NTP LI bits indicate the sync state of the NTP reference and if a leap second is scheduled to occur e Added a mechanism to automatically restart NTP when it has only one available reference and if that reference changes its time by more than 10 minutes o Example User User is the only valid input reference and if a user manually changes the time by more than 10 minutes NTP will be restarted Otherwise NTP would stop using the reference Version 4 8 2 Option Card features e Released four new Option Cards Models 1204 21 1204 26 1204 28 and 1204 29 www spectracomcorp com 5 SecureSync Release Notes 4 x spectracom System features e Added software support for four new Option Cards Models 1204 21 1204 26 1204 28 and 1204 29 e Added feature to support separate on time point pulse widths from standard pulse widths for generated square wave outputs e Oscillator disciplining enhancement that provides a growing time constant to provide b
18. e display to be selected via the front panel LCD and keypad but not via the web browser Version 4 1 0 adds a Local Clock drop down selection to the Setup Front Panel page of the web browser in order to configure the front panel LED time display e Added ability to send each individual log file to a Syslog server o Version 4 1 0 adds fields to define up to five separate Syslog servers to be able to send each log file to a Syslog server for remote log storage e GPS altitude field now allows a negative value Below Sea Level to be entered o Version 4 1 0 now allows a negative value to be entered in the GPS altitude field Previously only positive values would be accepted e Added support for the RS 485 and RS 232 ASCII time code RS 485 and RS 232 Input Output Option Modules o Version 4 1 0 allows ASCII time code Input Output Option Modules to be installed www spectracomcorp com 24 SecureSync Release Notes 4 x speciracom Determining the version of software currently installed To determine the current software version of your SecureSync A Using the newer web browser interface Software versions 5 1 0 and above Log in to the unit s web browser user interface At the top of the page click on Tools In this drop down click on Upgrade Backup The System Configuration table on this page will contain a field stating System The number next to this is the current Archive software version
19. ectracom logo icon on the web browser window tabs e Re ordered the log tabs on the Tools gt Logs page of the web browser e Added a feature to allow enable disable and prefer of the Local reference clock driver for NTP from the Web UI Network gt NTP Setup page NTP Servers tab o When disabled this can help prevent NTP from switching back and forth from Stratum 16 to a higher Stratum such as Stratum 1 or 2 when NTP is syncing to a marginal input reference such as one with high jitter for instance www spectracomcorp com 4 SecureSync Release Notes 4 x spectracom e Combined the Time Scale and Local Clock selection fields on the web browser configuration page for the front panel display Setup gt Front panel page e Added a new Oscillator Disciplining Status page to the web browser Status gt Disciplining page o Reports phase errors TFOM and MaxTFOM values etc o Adds new indications for when the following conditions last occurred since power up gt The TFOM value last changed Defaults to 1 JAN 2000 00 00 01 if SecureSync hasn t synced yet Note The following default to None if SecureSync hasn t synced yet gt Input References last changed gt SecureSync declared either Sync or loss of Sync status gt SecureSync went into or out of Holdover mode Version 4 8 5 System features e Network General Setup page of the browser General tab now displays the hostnam
20. el 1204 15 e Added support for the new PTP Master slave Option Card Model 1204 12 e Implemented changes for SNMP monitoring o Added new Net SNMP MIB file for generic start restart or shut down traps o Implemented ability to configure control the Input Reference Priority table via SNMP o Added new CLI command testevent to send test notifications SNMP traps and email alerts e Added indication for type of 10 MHz Oscillator installed as viewed in the Status Time and Frequency page of the web browser e Configurable support for access to the web UI from load sharing systems that make requests from multiple IPs e Reversed the order of log entries the latest log entries are now at the beginning of the log files e Added the SecureSync Model and Serial Number to the web browser e Implemented NTP manycast mode supported via NTP expert mode e Added Client key generation for NTP Autokey e Implemented new NTP Status graphs as viewed on the Status NTP page of the web browser Time Offset frequency Offset and RMS Jitter tabs e Improved the logging of Option Card configuration changes Tools Logs page of the browser Journal log e Added a notice to the GPS Receiver mode configuration Standard Mobile for invalid combinations with associated Dynamics codes e Enabled a new feature that allows the Tx enable line to the UART in the Simulcast 485 communications option
21. ently supported Tools Notifications page of the browser e Fixed a defect that didn t allow the update of the PTP Option Card firmware when it was in master mode when the available PTP Option Card is installed e Fixed a defect that did not allow backup restore of the input reference priority table e Fixed a defect in the Web UI that caused the IRIG instance numbers in reference priority table to not be displayed e Fixed a defect that caused IRIG configuration setting to revert to other values after reboot e Fixed a defect that caused the timing system to be updated with the wrong time during update of the PTP option card e Fixed a defect that caused some Option Card update FPGA images to be written incompletely to the serial flash resulting in an FPGA that would not program properly Version 4 7 0 e Fixed two issues associated with SecureSyncs that have a Rubidium oscillator installed when entering the Holdover mode not applicable to SecureSyncs with either an OCXO or low phase noise OCXO oscillator installed o While in the Holdover mode no valid input references currently being available two potential conditions can occur 1 The SecureSync s 1PPS output can become erratic unstable 2 The SecureSync s System Time can significantly drift off from the correct time causing significant time errors to occur e Resolved an issue where only one user can be logged into the SecureSync web browser without causing
22. equency Error Phase Error and DAC values graphs were added to display the monitoring of the internal 10 MHz oscillator operation www spectracomcorp com 2 SecureSync Release Notes 4 x spectracom Version 4 8 7 Option Card features Model 1204 12 PTP Option Cards if installed e Loss of PTP FollowUp packets is now detected o If this occurs the PTP Slaves remain in an Uncalibrated state as is also the case with the loss of Sync status or Delay_Response packets e Removed the need to Save Settings to ROM after configuration changes are made e The PTP module is automatically restarted when required by configuration changes being made by a user System features e Added alarm masking capability in the Tools gt Notifications page of the web browser to allow users to be able to disable unwanted alarm indications Note The Log files will still indicate the alarm condition has been asserted but the corresponding Alarm Fault lamp indications won t be asserted o Examples of alarm indications that can now be masked include gt Antenna Problems Alarms if the GPS antenna is not connected for example gt Frequency Alarms if the NTP server is synced only to other NTP servers user hand set time etc and therefore the oscillator is not being disciplined This operation results in the Frequency alarm being asserted e Increased the number of ssh ftp scp sftp logins and http https connections from 5 to 15 o
23. etter phase noise This results in fewer adjustments to the oscillator control DAC e MAC address is now only displayed on the Web UI for users with admin rights e Implemented new front panel Power LED indications o GREEN w ORANGE BLINKING Power fault Power inputs don t match configuration o ORANGE SOLID DC ONLY DC only power detected AC amp DC supported o ORANGE SOLID AC ONLY AC only power detected AC amp DC supported o GREEN SOLID All configured power is present e Added additional password security options configurable from the Web UI o Added configurable password complexity requirements e Added a new read only object to the SNMP MIB to allow getting the system time and date o New versions of the SNMP MIB files are available to support this new capability Version 4 8 0 Option Card features e Released new Stanag Option Cards Models 1204 1B and 1204 1D System features e Added out bound network tools to the command line interface for troubleshooting network issues associated with the SecureSync s network o Added the following network troubleshooting tool commands ifconfig arp rarp route netstat domainname dig host nslookup and traceroute e Added SNMP trap and or Email alerts upon each SecureSync reboot when enabled o The new reboot trap email alert requires new MIB files to be compiled in the SNMP Manager the new MIB files can either FTP SCP transferred out of the SecureSync s ho
24. he following characters A Z a z 0 9 and _ A space character will be replaced with an underscore e Fixed a defect that caused reload of Web UI pages to default to the first tab on the page instead of the previously selected tab on the page e Fixed a defect that caused the previous HTTPS certificate request to be displayed when creating a new HTTPS certificate request Version 4 8 5 e Applicable only to SecureSyncs with Archive version 4 8 4 software installed and one of more Model 1204 12 PTP Option Cards currently installed Fixed a defect in the Setup Inputs or Setup Outputs PTP Option Card page of the browser which prevented some of the tabs from being displayed and therefore prohibited configuration of the installed PTP Option Cards s Version 4 8 4 Software changes incorporated for potential security vulnerabilities e Fixed a defect that was preventing a fix added in version 4 8 2 software against a potential security vulnerability CVE 2011 3389 Protocol Weak CBC Mode from being applied during a software update Other software enhancements e Users can now save and re save overwrite the existing configuration archive file via the web browser o Performing a Restore configuration will delete the configuration archive file www spectracomcorp com 17 SecureSync Release Notes 4 x spectracom Fixed defects affecting the processing of leap second insertion when using a System Time
25. ient for access e Added two new proprietary ASCII timecode messages for use with the RS 485 and RS 232 ASCII Option Cards Version 4 2 0 e Implemented changes to support the Gigabit Ethernet Option Module P N 1220 06 which adds capability of having three additional Ethernet ports in addition to the base Ethernet port supplied with all SecureSync appliances o The Gigabit Ethernet Option Module For three additional Ethernet ports was made available for SecureSync Version 4 2 0 software changes were incorporated to accommodate the configuration of the three additional Ethernet ports that are provided by this Option Module o In support of multiple Ethernet ports added a Management Access table to define which network computers can access SecureSync using the available Management protocols such as HTTPS telnet SSH etc e Added idle time login restrictions and a logout button to the web browser o For security purposes added a logout button to the SecureSync s web browser interface o For security purposes users are automatically logged out of the web browser interface 15 minutes after the last keyboard or mouse click has occurred Note The SecureSync s login screen will look a little different with version 4 2 0 software installed it is now a conventional web page instead of a pop up window This change is to incorporate the above network security features as well as to allow support for planned additional net
26. ing able to achieve GPS sync Starting with version 4 7 0 software after the GPS receiver has initially obtained the UT1 correction value from the GPS satellites and upon each power up thereafter SecureSync will now assume this correction value is unchanged since it was last powered down So GPS sync will now occur shortly after the GPS receiver is tracking at least four satellites instead of having to wait for the GPS receiver to read this specific data from GPS This change results in GPS sync typically occurring within about 2 to 3 minutes after each boot up In the highly unlikely chance that a UTC leap second has been asserted since SecureSync was last shut down a one second time correction will occur after initial time sync to GPS has been achieved This new UT1 correction value would then be used for all subsequent reboots e Added new Save Log Files field to the Tools Upgrade Backup page of the web browser and a savelog command to the list of available commands for the front panel SERIAL port o The Save Log Files field or the savelog command issued via the front panel can create a bundled file of all of the SecureSync s log entries Once this bundled file named securesync log has been created and placed in the home spectracom xfer log directory this file can then be manually transferred out of SecureSync using FTP or SCP in order to extract all log files with a single file for archivi
27. ix available slots having 4 IRIG Output Cards installed Version 4 5 0 Cleaned up both the list of available CLI commands deleted a couple of commands that were no longer going to be implemented and the CLI help GPS receiver now supports negative altitude Below Sea Level GPS alarm thresholds can now be disabled Minimum satellite alarms Fixed an issue with a Rubidium 1PPS output offset occurring at start up Applicable only to SecureSyncs with a Rubidium Rb oscillator installed O Eliminated a 150ns 180ns variable offset to the 1PPS after each start up After each start up this 1PPS offset value wasn t consistently the same value GPS Qualification log now shows all 3600 seconds of each hour was intermittently displaying less than 3600 seconds for the hour such as 3599 seconds instead of 3600 Added a sub second placeholder of x 00 tenths and hundredths of a second to the NMEA ASCII Data streams o The NMEA 0183 specifications require the hour minute and second time data be provided in the ASCII data streams Sub second time information is optional per this specification However if a manufacturer of a device does not closely follow the NMEA 0183 data stream specifications they may expect to see sub second data values included in the input data streams Version 4 4 S adds a sub second tenths and hundredths place holder value to the ASCII data streams for those systems that may be expecting to see sub
28. le lists all available input references that can be provided to SecureSync such as GPS IRIG Stanag ASCII data etc If each listed input either has no external reference signal connected to it or the external reference is considered invalid the fields in the table will no longer indicate ALARM with a red fill The fields will now display Not Valid with orange fill instead Version 4 3 2 e Prevents intermittent erroneous Frequency Error alarms from occurring when a Rubidium oscillator is installed On rare occasions these alarms were still occurring in version 4 3 1 software O Resolved an intermittent issue with the 1PPS input reference provided to the Rubidium oscillator for the internal disciplining of its 10 MHz output Version 4 3 1 e Prevents intermittent erroneous Frequency Error and Oscillator Maintenance alarms from occurring when a Rubidium oscillator is installed Also prevents large phase noise measurements from intermittently occurring O Measurements of the Rubidium oscillator s output frequency were being affected by the oscillator internally changing its time constants while in the middle of performing frequency measurements This was affecting the formula that is used to calculate the frequency error which was resulting in the calculated frequency errors intermittently and erroneously being www spectracomcorp com 23 SecureSync Release Notes 4 x spectracom larger than they a
29. mber to prevent System Time from asserting the Leap Second too early Fixed a minor defect causing Not Supported to be displayed when resetting the admin password from the front panel keypad Fixed a defect causing the unit to add an entry to the Journal log that the battery backed time sync is changed enabled every time the Setup Time Management page of the browser is submitted by a user Fixed a defect causing a DHCP lease to be used instead of a user configured static IP address Fixed a defect causing the DNS servers and host name values to not be retained after submitting a change to them from the web browser Fixed a defect that was causing units with a commercial GPS receiver installed to potentially enter holdover for 130 seconds after a GPS Week rollover www spectracomcorp com 18 SecureSync Release Notes 4 x spectracom Fixed an issue that prevented creation of a local system clock with a name that is a sub string of another name for a local system clock Fixed a defect that caused single satellite mode to fail in some SecureSyncs with a commercial GPS receiver installed Fixed a defect that was preventing the clearing of GPS settings Reference Priority Table and Local System Clocks back to the factory default state after a clean operation was performed Status Power page of the browser now only displays the AC and or DC input power configuration s which is actually installed o For example if the NTP
30. me spectracom mibs directory or emailed from Spectracom Tech Support e Added new Battery Backed Clock option for those customers who don t care about accurate traceable time to external references those that desire to just have a relative time source instead of deriving time from an external time reference Added the ability for SecureSync to declare Time Sync after each boot up with no additional user interactions being required o Earlier versions of software required user interaction for those who wanted SecureSync to sync with no external time reference as the time had to be manually set to declare it valid after every reboot power cycle This new checkbox alleviates this user interaction requirement Version 4 7 0 www spectracomcorp com 6 SecureSync Release Notes 4 x spectracom Option Card features e Released new Event Capture with Broadcast Option Card Model 1204 23 System features e Faster GPS synchronization after reboots power cycles o When using GPS as a SecureSync input reference the time it takes for GPS to re synchronize after any subsequent reboots or power cycles that may occur is now significantly reduced In previous versions of software SecureSync could take anywhere up to about 13 minutes to resynchronize with GPS This delay was needed in order to read the UTI time correction provided in the GPS ephemeris data message which is broadcasted by the GPS satellites every 12 5 minutes prior to be
31. ng purposes or if is necessary to send the logs to Spectracom Tech Support for review e Added stateset to the list of available commands for the front panel SERIAL port o The stateset command can be used to perform either of the following from the front panel 1 Read the configured entries in the Input Reference Priority table 2 Enable disable or change the priority of each of the individual entries in the Input Reference Priority table e Added clean to the list of available commands for the front panel SERIAL port o The clean command resets the SecureSync back to factory default configurations and deletes log files Clean does not reset the GPS receiver or the stored GPS position information e Applicable only to SecureSyncs with a SAASM GPS receiver installed added HotStart to the list of available commands for the front panel SERIAL port www spectracomcorp com 7 SecureSync Release Notes 4 x spectracom Version 4 6 0 e Enhanced networking functionality relating to the available multiple port Ethernet Option Card Model 1204 06 o Added Static Route control for all interfaces and a main common route section o New routing tables were added to allow SecureSync to be able to exchange packets with subnets that are not directly connected to the base SecureSync Ethernet port or to the three available Ethernet ports of the Gigabit Ethernet Option Card subnets that are connected via rou
32. nual updates Manual updates reflecting the software changes have been uploaded to the Support page of Spectracom s website Please refer to http www spectracomcorp com Support HowCanWeHelpY ou Library tabid 59 Default aspx EntryId 218 to download the latest version of the SecureSync manual Hard copies of the new SecureSync manual may also be purchased from the Spectracom Sales department at US 1 585 321 5800 www spectracomcorp com 26 SecureSync Release Notes 4 x spectracom Spectracom Tech Support Please contact one of the global Spectracom Technical Support centers for more information regarding any of these features or fixes USA www spectracomcorp com techsupport spectracomcorp com 1565 Jefferson Road Suite 460 Rochester NY 14623 USA 1 585 321 5800 FRANCE www spectracom fr techsupport spectracom fr 3 Avenue du Canada 91974 Les Ulis Cedex 33 0 1 64 53 39 80 UK www spectracom co uk techsupport spectracom co uk 6A Beechwood Chineham Park Basingstoke Hampshire RG24 8WA 44 0 1256 303630 www spectracomcorp com 27 SecureSync Release Notes 4 x
33. ocal Clock with the name of UTC 5 because a factory default system Local Clock name of UTC already exists e The Software Update process was made to be more robust and continues even if individual Option Card updates happen to fail o Update process logging is improved to include recording when the software update process begins o Adds more details concerning any update problems which may have occurred during the update process e New Log entries can now be written after log files have been cleared o A System Reboot is no longer required to be performed after deleting log files e Applicable only to SecureSync s with a Rubidium oscillator installed Corrected display of DAC Get Errors being displayed in the Status gt Disciplining page of the web browser e Applicable only to SAASM GPS receiver installed Improved Leap Second and UTC GPS offset detection e Fixed a very minor reporting issue when performing a status CLI command with NTP disabled which caused the top of the response to indicate error heading Version 4 8 6 www spectracomcorp com 15 SecureSync Release Notes 4 x spectracom Option Cards enhancements Model 1204 06 Gigabit Option Card if installed e Fixed a defect that can potentially and randomly cause dropped network packets without any notification this is occurring o Could result in loss of ping HTTP HTTPS NTP SNMP etc o This applies only to the three network por
34. p com 14 SecureSync Release Notes 4 x spectracom e Applicable only to Model 1204 02 ASCII RS 232 Option Card now aligns the PPS input signal to the rising edge rather than the falling edge Model 1204 0B RS 485 Comm Protocol Option Card if installed e Modified the RGCS command to report information on all 12 GPS receiver channels instead of just 8 channels o The maximum number of reported satellites being tracked is 8 even if the GPS receiver is tracking 12 satellites for instance e Added 1FO ACD and AT3 commands to emulate RS485 communications with Model 8195 series Master Oscillators System enhancements e Resolved an issue with the commercial GPS receiver restarting its GPS survey after each power up if the GPS Mode configuration has been repeatedly toggled between available modes From Standard mode to Continuous Mobile mode and then back to Standard mode again for instance o Normally the 34 minute GPS Survey is only performed once after the first power up at a new location o The GPS receiver restarting its GPS survey after each power up was delaying the time required to attain initial time synchronization to GPS after each power up e When creating a new Local Clock Setup gt Local Clock page of the web browser corrected a defect forbidding the use of Local Clock names which are super sets of other local clock names that already exist o An example of this includes not being able to create a new L
35. pabilities Tools Users page of the web browser Security tab o Configurable idle time outs can either disable or configure how long after no activity before the need to login again o Password aging can enable the ability to either prevent the passwords from being changed and or configure them to expire before or after a configurable amount of time o Password complexity can enable minimum criteria for new passwords when they are created o Can remove default factory accounts Hard coded in software not configurable www spectracomcorp com 8 SecureSync Release Notes 4 x spectracom o Limits the number of failed login attempts before needing to wait to try again o Password re use can t re use the last 10 previously used passwords e Enhanced the version CLI command to be able to query for the specific versions of the different SecureSync modules Apache SSH SSL etc e Added support for Simulcast features CTCSS Data Clock Data Sync Option Card Model 1204 14 e Added support for RS 485 Communication Protocol Option Card Model 1204 0B e Added support for a four 1PPS outputs Option Card Model 1204 18 e Added support for the Alarm Relay Minor Major alarm Option Card Model 1204 0F e Added support for the four square wave output Option Card Model 1204 17 e Added support for the new SAASM GPS receiver Option Card Model 1204 1A e Added support for the new four output IRIG Option Card Mod
36. rvset CLI interface commands now include SNMP and NTP in the list of Services that can be stopped started or the current running status viewed using these two CLI commands Version 4 8 8 Option Card features Models 1204 07 and 1204 1A SAASM GPS receiver if installed e Added zeroize command to CLI to support emergency zeroize and zeroize keys e Added emergency zeroize to occur with all clean commands Model 1204 09 E1 Output Option Card if installed e Added SSM Sync Status Messaging functionality e Add 75ohm T1 DS1 output capability o This Option Card can now provide either 1 544 MHz DS1 outputs OR 2 048MHz E1 outputs Model 1204 12 PTP Option Card if installed e Added PTP Unicast mode e Added PTP Minicast mode Combination of both Unicast and Multicast modes Model 1204 0A T1 E1 Output Option Card if installed e Added SSM Sync Status Messaging functionality System features e Added New CLI Command Line Interface commands o Added two new CLI commands to support the ability to perform remote scripted configuration file backups includes the saveconf command to save configs to a tar file inside SecureSync and the loadconf command to load configs from a tar file inside SecureSync o Added the sysupgrade CLI command to support the ability to perform remote scripted software updates if desired e Added three new graphs to the Status gt Disciplining page of the web browser o Fr
37. rwise However if the Submit button was pressed again while in this state the functionalities would then become disabled e Changed the default DNS server configuration to having no DNS servers specified o Having one or both DNS server configured in the SecureSync but no DNS server actually exists on the network with those addresses can result in delays while trying to establish telnet ssh and other network based connections with the SecureSync These connections will attempt to communicate with the configured DNS servers but if they don t actually exist the attempted connections will eventually just time out However if no DNS servers are incorrectly configured no attempt to contact the DNS servers will occur alleviating any unnecessary delays when establishing these connections e Added necessary additional spaces to the EndRun ER and ERX ASCII output formats e IP address prefix fields are now grayed out on the web browser when DHCP is enabled o Prevents the ability to manual change network settings that have been configured by a DHCP server e Having a local clock selected for the front panel LCD display will no longer affect the UTC time in the system o System Time can now be manually entered using the time scale that it is configured to display if the LCD displays local time the time can be manually entered as local time instead of needing to first convert local time to UTC in order to enter the time as UT
38. s being installed when PTP Option Cards were also installed in Slots 1 through 4 Model 1204 17 Square wave output Option Card if installed e Couldn t set period and scale without error o Period and Scale values are now calculated at the same time to avoid incompatibilities Model 1204 28 Option Card if installed e Added control for the third 1PPS output o Earlier software versions did not display configuration selections for all three separate 1PPS outputs that are available from this Option Card Instead it displayed only two The 3rd 1PPS output was still present but it was not configurable Model 1204 0B RS 485 Comm Protocol Option Card if installed e Modified rgcs command to output support for up to 12 satellites 8 or more satellites display as a value of 8 www spectracomcorp com 13 SecureSync Release Notes 4 x spectracom e rach output message contained an extra linefeed OxOA value Removed to make message 39 characters long Security related software changes incorporated e Updated Apache web server to version 2 2 23 to mitigate potential vulnerabilities o CVE 2012 0053 Apache httpOnly Cookie Disclosure o CVE 2012 0031 Apache denial of service o CVE 2011 3607 Apache Integer overflow in the ap_pregsub function in server util c o CVE 2011 3192 httpd Range header remote DoS o CVE 2000 0868 Apache CGI Source Code Viewing Vulnerability e Changed fac
39. ters to the networks connected directly to the SecureSync gt Each of the three network ports on the Gigabit Option Card now has an available default gateway address for configuring the router s address for each network port gt The new main routing table is used to route network traffic that does not originate from networks connected directly to SecureSync such as unrequested SNMP traps that can be sent from SecureSync upon events occurring o Enhanced front panel LCD display keypad operation and CLI interface to support the changes made to the network functionality e Faster NTP synchronization time to transition out of Stratum 16 after each power cycle reboot o Once SecureSync has declared Sync with one or more input references such as GPS IRIG User set time etc as indicated by the front panel Sync LED turning green NTP will now achieve synchronization as indicated by Stratum 1 Stratum 2 etc much faster than in earlier versions of the SecureSync software The NTP s minpoll interval was changed in this version from 64 seconds to 16 seconds so NTP can poll the System Time much faster resulting in NTP Stratum 1 synchronization after each power up reboot in about 5 minutes instead of about 17 minutes as was required in earlier versions Version 4 5 0 e Added a new Oscillator Log to the list of available SecureSync logs Tools Logs page of the web browser e Enhanced security login ca
40. tory default RSA Private key Bit length to 2048 and added support for SSH Elliptic Curve DSA ECDSA keys of 512 384 521 bits e Added autocomplete off to password input line on login page to mitigate potential security vulnerability Web Server Allows Password Auto Completion PCI DSS variant System enhancements e Syslog log messages now report the current hostname rather than a hard coded hostname of Spectracom Version 4 8 7 Option Card enhancements Model 1204 12 PTP Option Card if installed e PTP Clock Identity values of all 1 s are recognized and acknowledged to PTP Master as valid e Removed the following web browser tabs associated with PTP for simplification of setup o PTP Setup Module Tab o PTP Setup Statistics Tab o PTP Setup VLAN Tab Model 1204 05 and 1204 15 IRIG Option Cards if installed e The IEEE 1344 Extensions when configured to be included in the IRIG output data stream s Control Functions CF fields now only provide Local time DST and Time Zone Offset information if a Local Clock name has been selected as the output timescale Models 1204 02 and 1204 04 ASCII output Option Cards if installed e Removed support for Spectracom Format 4 as an input reference selection for synchronization e Fixed a case where the Timing System would lock up requiring a reboot if switching from a selected format to the NONE drop down when using the ASCII output www spectracomcor
41. ts on this Option Card Eths 1 2 and 3 Does not apply to the base Ethernet port Eth0 installed on all SecureSyncs Model 1204 12 PTP Option Card if installed e Fixed a condition that can cause a one second PTP output time error when SecureSync is first synced to a Stratum 1 time server via NTP and if the PTP Option Card is configured as a PTP Master e Fixed a defect that caused the software update of multiple PTP option cards to fail Important Note SecureSyncs with multiple PTP Option Cards installed must first be updated to special release version 4 8 P prior to updating to version 4 8 6 in order to update more than one installed PTP Option Card Contact Tech Support for more information or to obtain the version 4 8 P software update file e Fixed a defect that caused the PTP Option Card to not respond to ping requests e Fixed a defect that caused the Web browser update page to stall when updating this Option Card e Removed FTP configurations for software update from the web browser o Software updates to the PTP Option Card are handled by the SecureSync Update process Manual FTP update file transfers directly to the PTP module are not needed Models 1204 01 and 1204 18 1PPS input Option Cards if installed e Made improvements to the FPGA implementation to address 5ns shifts of the 1PPS output when these Option Cards are installed in rear panel slots 5 or 6 Model 1204 0F Relay Option Card if installed e Fixed a
42. work security features such as limited number of login retries a login banner etc to be added in future software releases www spectracomcorp com 10 SecureSync Release Notes 4 x spectracom Version 4 1 0 Implemented Expert Mode for NTP configuration o Normally NTP is configured using the SecureSync s web browser pages Some users may prefer to edit the NTP conf configuration file directly instead of using the supplied web browser pages Expert Mode allows the NTP conf file to be edited directly by a user Please refer to the SecureSync instruction manual for more information on the Expert Mode prior to using this new configuration method e Improved SNMP Event Notification capability and added Email alert capability o Added a web browser Notification page to configure whether each SecureSync event that may occur such as loss of Time Sync going into or out of the Holdover mode etc will trigger an SNMP trap or an email or both to be sent out to a desired email recipient In version 4 0 0 two SNMP traps were available the Time Sync trap and the Holdover trap Version 4 1 0 also adds several new available traps such as a minimum satellites trap frequency alarm traps etc Each SNMP trap can be either selected or de selected as desired e Added the ability to either enable disable for NTP to prefer the System Timing references and configuration to either use or not use the System Time s 1PPS when using Secure