Home
AWK-4630 Workstation
Contents
1. Step 2 Click Standard Calibration FJ Device 0 PenMount 9000 25232 Advanced Mode 9 Plot calibration data i B Turn off EEPROM storage ADP 1XX5A User Manual 25 NOTE The older the touch screen is the more Advanced Mode calibration points you need for an accurate calibration Use a stylus during Advanced Calibration for greater accuracy Advanced Calibration click Advanced Calibration JF Device 0 PenMount 9000 R5232 Advanced Mode Plot calibration data Standard Calibration Advanced Calibration Turn off EEPROM storage ADP 1XX5A User Manual 26 Plot Calibration Data Check this function and a touch panel linearity comparison graph appears when you have finished Advanced Calibration The blue lines show linearity before calibration and black lines show linearity after calibration Multiple Monitors Multiple Monitors support from two to six touch screen displays for one system The PenMount drivers for Windows XP 2003 Vista 7 support Multiple Monitors This function supports from two to six touch screen displays for one system Each monitor requires its own PenMount touch screen control board either installed inside the display or in a central unit The PenMount control boards must be connected to the computer COM ports via the RS232 USB interface Driver installation procedures are the same as for a single monitor Multiple Monitors support the follow
2. APLEX ADP 1XX5A High Brightness Display Monitor User Manual Release Date Revision Feb 2015 V1 2 92015 Aplex Technology Inc All Rights Reserved Published in Taiwan Aplex Technology Inc 15F 1 No 186 Jian Yi Road Zhonghe District New Taipei City 235 Taiwan Tel 886 2 82262881 Fax 886 2 82262883 E mail aplex aplex com tw URL www aplex com tw ADP 1XX5A User Manual 1 Warning This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual it may cause interference to radio communications It has been tested and found to comply with the limits for a Class A computing device pursuant to FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference Electric Shock Hazard Do not operate the machine with its back cover removed There are dangerous high voltages inside Disclaimer This information in this document is subject to change without notice In no event shall Aplex Technology Inc be liable for damages of any kind whether incidental or consequential arising from either the use or misuse of information in this document or in any rel
3. X 0 97MB Ah 6 45MB Die ig 2014 9 20 X 4839 X 1109 12 30 X 4 54MB Ah 131 00MB Fels 3 493 00MB X 0 58MB X 23 35MB Select Yes and Close to remove the PenMount Windows XP 2003 Vista 7 driver and reboot the system ADP 1XX5A User Manual 32 lt Chapter 5 Software 5 1 Software Functions This chapter describes the special software functions that configure and adjust the PenMount controller board and touch screen hardware Please note that not all of the functions are available for every driver Software functions and their availability for specific interface and systems are shown in the table below a description for each function follows e e _ E CIT Wewewmun 0 0 t Gewewde e _ e _ Double Click Area ADP 1XX5A User Manual 33 5 2 Software Function Description Description for each of the software functions shown in the table above follows Standard Calibration The Standard Calibration function lets you match the touch screen to your display so that the point you touch is accurately tracked on screen Standard calibration only requires four points for calibration and one point for confi
4. Frances Deutach 5 Germany ql TE Spanish Traditional Chinese Simplified Chinese Japanese In the Misc menu there are Ver 1 3 Signal Source bps Select VGA Analogue VGA Input Select DVI Digital DVI D Input Select AV Composite Video Input Select SV S Video Video Input Reset Back ADP 1XX5A User Manual Chapter 3 Control Board 3 1 Introduction to PenMount 9036CH5 Control Board for RS 232 interface Touch Screen PenMount 9036CH5 Control Board is a powerful RS 232 touch screen control board to support 5 wire touch screen by executing the same drivers as all PenMount series control board and ICs PenMount 9036CH5 is good for all kinds of resistive touch screens user could put PenMount 9036CH5 control board in different systems space and connected to system s serial interface There are two connectors on board one connector is for the power and RS 232 interface power line is allowed to have 5V input RS 232 interface cable has 9 pin D sub connector another is for 5 wire different touch screens PM9036CH5 supports 5 wires touch panel there s ohm resistance of R13 in the circuit therefore we don t mount the component There s ohm resistance of R12 in the circuit Figure 3 1 Bird s Eye View of PM9036CH5 Control Board ADP 1XX5A User Manual 15 Mechanical Size of PM9036CH5 PenMount 9036CH5 Control Board 60 0 25 356 r N 0 e n v X 356
5. Unitmm PenMount 9036CH5 Control Board 60 0 Side View eo Unit mm Figure 3 2 Mechanical Size of 9036 5 Control Board Connector Definition JP2 Touch Screen Lines JP1 RS 232 Connector PIN 2 Power Input rn Gud Driver Software Windows XP 2003 2008 Vista 7 Windows CE 6 0 ADP 1XX5A User Manual pneu Pme sense _ 16 Electrical Specifications Electrostatic Discharge Air Discharge 15KV Mechanical Size 60 x 26 mm two screw holes Power Consumption Standby Mode 16 mA Active Mode 27 5 mA VCC 5V Top sheet Panel Resistance 365 ohm Bottom sheet Panel Resistance 660 ohm Note Actual current will be different by touch panel s resistance ADP 1XX5A User Manual 17 3 2 Introduction PenMount 6300 5 Control Board for USB interface Touch Screen PenMount 6300A5 USB control board is a touch screen control board designed for USB interface and specific for 5 wire touch screen It is designed with USB interface features with multiple devices supporting function PenMount 6300A5 control board using PenMount 6000 controller that has been designed for those who may like all in one solution with A D converter built in make the total printed circuit board denser There two connectors on this board one connectors is 5 wire touch screen cable and the other is for 4 pin USB A type cable PIVI6300A5 supports 5 wires touch panel there s oh
6. control board or PenMount 6300A5 USB Interface control board installed If you have an older version of the PenMount Windows XP 2003 Vista 7 driver installed in your system please remove it first Follow the steps below to install the PenMount Windows XP 2003 Vista 7 driver 1 The screen displays the installation wizard for the PenMount software Click Next Welcome to the PenMount Windows Universal Driver 2 42325 Setup Wizard This wizard will guide you through the installation of PenMount Windows Universal Driver 2 4 2 325 It is recommended that you close all other applications before starting Setup This will make it possible to update relevant system files without having to reboot your computer Click Next to continue ADP 1XX5A User Manual 21 2 License Agreement appears Click I accept and Next PenMount Windows Universal Driver V2 4 2 325 Setup TOME OPES Please review the license terms before installing PenMount Windows Universal Driver V2 40 3 325 Press Page Down to see the rest of the agreement PLEASE READ THE LICENSE AGREEMENT PenMount touch screen driver software 1s only for using with PenMount touch screen controller or control board Any person or company using a Pen Mount driver on piece of equipment which does not utilize an touch screen controller will be prosecuted to the full extent of the law If you accept the terms of the agreement
7. dick I Agree to continue You must accept the agreement to install PenMount Windows Universal Driver V2 4 2 325 MullsaFE Install System v2 46 3 Click Install to begin the installation Setup will install PenMount Windows Universal Driver V2 4 2 325 in the following folder To install in a different folder dick Browse and select another folder Click Install to start the installation I Program Files x86 PenMount Windows Universal Driver Space required 0 0KB Space available 136 868 Hullsoft Install System v2 46 ADP 1XX5A User Manual 22 4 Click Yes to continue PenMount Windows Universal Driver V2 4 2 325 Setup Click Yes if you want to use PenMount touch features Click No if you want to use system touch gestures 5 Click Finish to com plete the installation PenMount Windows Universal Driver V2 4 2 325 Setup ADP 1XX5A User Manual Completing the PenMount Windows Universal Driver 2 4 2 325 Setup Wizard PenMount Windows Universal Driver V2 4 2 325 has been installed on your computer Click Finish to dose this wizard 25 4 2 Configuring the PenMount Windows XP 2003 Vista 7 Driver Upon rebooting the computer automatically finds the new PenMount 9036 RS232 interface controller board or PenMount 6300 USB interface controller board The touch screen is connected but not calibrated Follow the procedures below to carry out calibration 1 After installation click th
8. drag function of the touch screen The point mode only allows touch interaction with the screen and does not allow the user to drag objects The point mode is useful for maintaining the location of screen icons such on POS terminals The stream mode allows a user to touch and drag icons and other items around on the screen similar to using a mouse ADP 1XX5A User Manual 37 Drawing Mode Drawing mode is a utility that lets the user draw on the screen using a finger or stylus This allows the user to test the touch screen and touch controller to see if it is operational or is mapped correctly The drawing mode can display either the matrix address of points touched or just show lines drawn One of the PenMount driver s strengths is a special mathematical algorithm that minimizes the occurrence of noise and smooths the drawing of lines Beep Sound All of PenMount s drivers support the beep sound function however some PC systems may only offer a fixed buzzer sound Beep Sound Adjustable Software drivers for Windows systems let the user adjust the frequency and length of the beep sound The drivers let the user adjust the desired touch screen sound as well as turn the sound off Wake Up Function The Wake Up function lets the user touch the screen and wake the system up from suspend mode Point Calibration Data The Plot Calibration Data function displays the touch screen linearity map which is available i
9. 00 6000 Series drivers The drivers for PenMount 9000 6000 Series can support up to six control boards Comparing Functions The difference between the Multiple Monitors function and the Multiple Devices function are illustrated below or The Multiple Monitors function shown above extends the screen into 2 more The Multiple Devices function displays the same image on two more monitors monitors ADP 1XX5A User Manual 35 Rotation There are currently a number of software packages on the market that support rotating monitors 0 90 180 and 270 However you will not be able to use a touch screen unless it is matched to the appropriate rotation Our rotation configuration function allows you to easily match the touch screen when you rotate your monitor If you use a rotating monitor you will need a display card such as from nVidia Intel SMI or ATI and software such as Portrait Pivot Pro For software operation and features please refer to your software manual Configuring the rotation function is easy Select this option and a point appears for you to touch Once the point is touched the software driver understands which degree you plan to rotate your display The rotation function supports 90 180 and 270 degrees rotation degrees 90 degrees ADP 1XX5A User Manual 36 180 degrees 270 degrees Stream Point Mode Stream and point modes control the touch and
10. A User Manual 6 000000900 oppona 00 000 HHH TTT TTT E Dmm mmn 290 00 292 00 r3 m SERE gt mco Dm _ 228888 392 00 Mounting Hole Size Figure 1 2 Dimensions of ADP 1155A ADP 1XX5A User Manual 7 ier e M4 TAPP 0000000000082000000 102000000080 O 69 3 Ol 379 00 362 00 Figure 1 3 Dimensions of ADP 1195A ADP 1XX5A User Manual 8 1 4 Brief Description of the ADP 1XX5A ADP 1125A 1155A 1195A is a Steel Enclosure LCD Display that comes with a 12 1 inch 15 inch 19 inch luminance of 1000 cd m LCD and more outstanding features thus giving you the best in monitoring and control applications The front panel of the display is sealed IP65 rating when it is VESA mounted in a NEMA rated cabinet or enclosure It is optional to be equipped with a resistive touch screen Figure 1 5 Rear View of ADP 1XX5A ADP 1XX5A User Manual 9 1 5 Display Mode Display Mode Hori Sync KHz Vert Sync Hz XGA 1024 x 768 ADP 1XX5A User Manual 10 Chapter 2 OSD 2 1 Front Panel OSD Functions Auto Adjust Up Left Down Right Power Menu Entry Power Indicator P
11. and Left Button functions Exits the PenMount Monitor function Configuring the Rotation Function 1 Install the rotation software package 2 Choose the rotating function 0 90 180 270 in the gi party software The calibration screen appears automatically Touch this point and rotation is mapped Please touch the point gt NOTE rotating function is disabled if you use Monitor Mapping ADP 1XX5A User Manual 31 4 3 Uninstall the PenMount Windows XP 2003 Vista 7 Driver 1 2 BER Tels 2570 3 Exit the PenMount monitor PM in the menu bar PenMount Windows Universal Driver and click the Add Remove button 8 Microsoft SQL Server Database Publishing Wizard 1 4 Microsoft SQL Server Desktop Engine Microsoft SQL Server System CLR Types g Microsoft SOL Server VSS Writer 3 Microsoft Sync Framework Runtime v1 0 SP1 x86 zh CHT Microsoft Sync Framework SDK v1 0 SP1 zh CHT e Microsoft Sync Framework Services v1 0 SP1 x86 zh CHT 3 Microsoft Sync Services for ADO NET v2 0 SP1 x86 zh CHT Microsoft Team Foundation Server 2010 71890 Se Pz Microsoft Visual C 2008 Redistributable x86 9 0 30729 4974 Microsoft Visual C 2010 x86 Runtime 10 0 40219 oo Microsoft Visual F 2 0 Runtime oo Microsoft Visual Ff 2 0 Runtime 28 KERN Microsoft Visual Studio 2010 ADO NET Entity Framework Tools Microsof
12. ated materials ADP 1XX5A User Manual 2 Table of Contents Warning 7 2 Chapter 1 Getting Started L 1 Features as 1 2 Specifications 1 3 Dimensions 1 4 Brief Baserhstion ADP AXX5A Rudd inea 1 5 Display Mode 10 Chapter 2 050 2 1 Front Panel OSD Functions 1 PA GIBT Ge glial 2 3 Main VT 1 Chapter 3 Control Board 3 1 Introduction to PenMount 9036CH5 Control Board for RS 232 interface Touch 5 Doo 3 2 Introduction to PenMount 630045 deant for USB Interface TOUCH Screen naar Chapter 4 Installation 4 1 Windows XP 2003 Vista 7 Universal Driver Installation for PenMount 9000 6000 series 4 2 Configuring the PenMount Windows XP 2003 Vista 7 fihus 24 4 3 Uninstall the PenMount Windows XP 2003 Vista 7 Driver 32 Chapter 5 Software FUNCU ON Gan 9 5 2 Software Function 34 ADP 1XX5A User Manual 3 Figures Figure 1 1 Dimensions of 1125 Figure 1 2 Dimensions of 11554 Figure 1 3 Dimensions of 1195 Figure 1 4 Front View of the 1 5 Fig
13. e PenMount Monitor icon inthe menu bar 2 When the PenMount Control Panel appears click Calibrate PenMount Control Panel The functions of the PenMount Control Panel are Calibrate Multiple Monitors Tools and About which are explained in the following sections Device In this window you can find out that how many devices are detected on your system lij PenMount Control Panel Device Multiple Monitors Tools About Select a device to configure 9000 65232 Configure Refresh Calibrate This function offers two ways to calibrate your touch screen Standard Calibration adjusts most touch screens Advanced Calibration adjusts aging touch screens ADP 1XX5A User Manual 24 Standard Click this button and arrows appear pointing to red squares Use Calibration your finger or stylus to touch the red squares in sequence After the fifth red point calibration is complete To skip press ESC Advanced Advanced Calibration uses 4 9 16 or 25 points to effectively Calibration calibrate touch panel linearity of aged touch screens Click this button and touch the red squares in sequence with a stylus To skip press ESC Standard Calibration Step 1 Please select a device then click Configure You can also double click the device too ig PenMount Control Panel Device Multiple Monitors Tools About Select a device to configure Configure Refresh
14. f the PenMount driver provides an Advance Calibration function when touch screens age their touch linearity declines This non linearity is apparent when the touched point on the touch screen is not the same as the point on the display The plot calibration data function shows the linearity status of the touch screen This is only a support function for the user The exact linearity of a touch screen requires a linearity test machine ADP 1XX5A User Manual 38 Right Button The Right Button function simulates the right button function of a mouse Click the right button and the user can only touch the screen once and the driver changes the touch definition to the left button Hide Cursor The Hide Cursor function keeps the cursor arrow and other cursor symbols from appearing when using the touch screen The cursor appears when the user turns this function off Cursor Offset The Cursor Offset function lets the user adjust the position of the touch point to a desired location away from the real touch point Double Click Area and Speed The Double Click Area and Speed function lets the user adjust the double click area and speed to their personal preference About This option shows the exact version of the drivers and controller firmware Updated drivers are available for download on the PenMount website ADP 1XX5A User Manual 39
15. first Then press the buttons don t let them go until the power is connected and wait 2 to 3 seconds When RGB appears repeat the above steps 2 2 OSD Controls To make any adjustment select the following 1 Press Menu to show the OSD menu disable the OSD menu 2 Select the icon that you wish to adjust with the T A or key in the menu 3 Press Menu and then choose the item with the T A or key 4 Press Menu and then adjust the quality with the T A or key ADP 1XX5A User Manual 12 2 3 Color Image Setting Position OSD Menu Language Ver 1 3 Contrast Brightness Color Adjust Color Te mp Back 1 3 Clock Phase FILII Sharpress Back ADP 1XX5A User Manual In the Main menu there are the following items Color Image Setting Position OSD Menu Language Misc Exit For Color check out the following Contrast Brightness Color Adjust Color Temp e o o Back For Image setting check out the following Clock Phase Gamma Sharpness o o o Back 13 Ver 1 3 In the Position there are the following H Position m V Fosti Position Beck V Position Back In the OSD menu there are OSD H Pos OSD V Pos OSD Timer Back In the Language menu there are 1 3 English English Frangais
16. ing modes Windows Extends Monitor Function Matrox DualHead Multi Screen Function nVidia nView Function NOTE The Multiple Monitor function is for use with multiple displays only Do not use this function if you have only one touch screen display Please note once you turn on this function the rotating function 15 disabled Enable the multiple display function as follows ADP 1XX5A User Manual 21 1 Check the Multiple Monitor Support box then click Map Touch Screens to assign touch controllers to displays li PenMount Control Panel Device Multiple Monitors Tools About 2 When the mapping screen message appears click OK 3 Touch each screen as it displays Please touch this monitor Following this sequence and touching each screen is called mapping the touch screens 4 all screens completes the mapping and the desktop reappears on the monitors 5 Select a display and execute the Calibration function A message to start calibration appears Click OK ADP 1XX5A User Manual 28 Calibrate To start callbration please touch the panel to callbrate in the following screen NOTES 1 If you use a single VGA output for multiple monitors please do not use the Multiple Monitor function Just follow the regular procedure for calibration on each of your desktop monitors 2 The Rotating function is disabled if you use the Multiple Monitor function 3 If you change the resol
17. m resistance of R12 in the circuit therefore we don t mount the component PenMount Figure 3 3 Bird s Eye View of PM6300A5 Control Board ADP 1XX5A User Manual 18 Mechanical Size of PM6300A5 56 5 Unittmm Side View Unit mm PenMount 6300A5 Control Board Figure 3 4 Mechanical Size of PM6300A5 Control Board Connector Definition JP1 USB Connector JP1 Touch Screen Lines ma uU rm sense _ Driver Software Windows XP 2003 2008 Vista 7 WinCE 6 0 ADP 1XX5A User Manual 19 Electrical Specifications Cursor accuracy lt 1 Active Area Diagonal of touch screen with PenMount Advanced calibration utility support Electro Static Discharge Air Discharge 15KV Power Consumption Standby Mode 13 4 mA Active Mode 21 5 mA VCC 5V Top sheet Panel Resistance 365 ohm Bottom sheet Panel Resistance 660 ohm Note Actual current will be different by touch panel s resistance ADP 1XX5A User Manual 20 Chapter 4 Installation This chapter describes how to install drivers and other software that will allow your touch screen work with different operating systems 4 1 Windows XP 2003 Vista 7 Universal Driver Installation for PenMount 9000 6000 series Before installing the Windows XP 2003 Vista 7 driver software you must have the Windows XP 2003 Vista 7 system installed and running on your computer You must also have the PenMount 9036CH5 RS 232 Interface
18. ower switch To turn ON or OFF the power Shift the icon to the right side or shift it up Shift the icon to the left side or shift it down Menu To enter OSD menu for related icon and item Auto Button One touch auto adjustment 1 Getting into Burn in Mode Before setting into a burn in mode first disconnect the AC power cord Then press don t letthem go the W buttons until the power cord is connected and the appears on the top left corner of your screen Now it can be put into the burn in mode for changing colors 2 Getting Out of Burn in Mode Before getting out of the burn in mode please first disconnect the AC power cord Then press the button If not workable press the A button and don t let them go until the AC power cord is connected Please don t let your fingers go until the AC power cord is connected again and the wording of RGB appears on the top left corner of your screen and wait for 3 seconds Under the non signal entry situation if Cable Not Connected is seen exit is thus successfully made ADP 1XX5A User Manual 11 When the Mode is Unable to Eradicate 1 Ifthe is still on the top left corner of the screen press to enter Miscellaneous and choose Reset and then Yes and press When the screen goes black disconnect power and repeat the above steps 2 If the RGB is not found disconnect the AC power cord
19. rmation Under normal circumstances Standard Calibration is all you need to perform an accurate calibration Advanced Calibration The Advanced Calibration function improves the accuracy of calibration by using more involved engineering calculations Use this function only if you have tried the Standard Calibration and there is still a discrepancy in the way the touch screen maps to the display You can choose 4 9 16 or 25 points to calibrate though we suggest that you first try 9 points if it is still not tracking well then try 16 or 25 points The more points you use for calibration the greater the accuracy Errors in calibration may occur due to viewing angle or individual skill and there may be little difference in using 16 or 25 points Note that a stylus is recommended for the most accurate results Multiple Monitors Until now most touch screen systems only support one monitor and users of multiple monitors have not been able to use touch screen systems This situation has inspired PenMount to design and develop Multiple Monitors support using the PenMount 9036CH5 6300A5 control board and Windows XP 2003 Vista 7 driver Our advanced design supports from 2 to 6 monitors that can be split horizontally or vertically ADP 1XX5A User Manual 34 Multiple Devices The Multiple Devices function is designed to let you use two or more monitors to display the same image Software that supports this function includes the PenMount 90
20. t Visual Studio 2010 Service Pack 1 oo Microsoft Visual Studio 2010 Tools for Office Runtime x86 38 Microsoft Visual Studio 2010 Tools for Office Runtime x86 888 99857 o0 Microsoft Visual Studio 2010 Ultimate 58425 amp Microsoft Visual Studio Macro Tools amp Microsoft Visual Studio Macro Tools CHT Language Pack 5 Monitor Asset Manager 5 MStar debug tool driver 4 PenMount Windows Universal Driver Y2 4 2 325 22m Et cim e te Ros 81220 Ar PERASA Realtek High Definition Audio Driver 5 Visual Studio 2010 Tools for SQL Server Compact 3 5 SP2 CHT WCF RIA Services V1 0 SP1 Web Deployment Tool Y WELLON Uninstall 15 Windows XP Embedded Database SP1 5 Windows XP Embedded Remote Boot Server T Windows XPe SP2 FP2007 Tools Windows u blox ubcdcacm2 Modem 08 07 2012 3 50 0 5 Windows u blox ubedeacm2 Ports 08 07 2012 3 50 0 5 Windows u blox ubusbmi2 USB 08 07 2012 3 50 0 5 Windows CHE u blox AG ubloxusb Ports 07 03 2013 1 2 0 8 HEARS Go to Settings then Control Panel and then click Add Remove program Select 51 x Ah 1018 Ah 6907MB 422 6 51 085MB 2980MB X 209MB 061 Zh 41800MB X 1019 X 26 4MB X 2 84MB Kh 0 55MB Fels 35 13MB X 16 31 Kh 7 23MB X 7 23MB Fels 2 201 00MB X 2825MB X 2825MB
21. ure 1 5 Rear View of the 1 5 Figure 3 1 Bird s Eye View of PM9036CH5 Control Board 15 OND Figure 3 2 Mechanical Size of PM9036CH5 Control Board 16 Figure 3 3 Bird s Eye View of PM6300A5 Control Board 18 Figure 3 4 Mechanical Size of PM6300A5 Control Board 19 ADP 1XX5A User Manual 4 Chapter 1 Getting Started 1 1 Features 12 1 15 19 High Brightness 1 000 cd m2 TFT LCD NEMA 4 IP 65 compliant front bezel Rear OSD VESA 75 75 and panel Mount Front glass with Anti Reflection optional touch screen AC 100 240V power input Default VGA input Optional for DVI Video and S Video input 1 2 Specifications moon LCD Viewing Angle H 178 V 178 H 140 V 125 H 170 V 160 H V Backlight Lifetime 50 000 Hours Hardware Default VGA Input AC 100 240V input Optional DVI Video S Video Touch I O ADP 1XX5A User Manual 5 External I O Port Dimensions 467 x 379 x 68 Operating 0750 Lm 2 20 60 21 Storage Humidity 10 90 240 non condensing 1 3 Dimensions TEP EEF TEF Er r Bri bilaks db Ji EE d 10001011101 c 10001107 0 50 11 Hi HI 0 0 1i 0 i MOUNTING HOLE et Te Figure 1 1 Dimensions of ADP 1125A ADP 1XX5
22. ution of display or screen address you have to redo Map Touch Screens so the system understands where the displays are Tools Tests or demonstrates the PenMount touch screen operation Right Button Icon Enable right button function The icon can show on Desktop or System Tray menu bar li PenMount Control Panel Device Multiple Monitors Tools About Test by drarwing on the touch screen Show Hide the icon for switching buttons Desktop System Tray Double Click Speed Slow Back to Default OK ADP 1XX5A User Manual About This panel displays information about the PenMount controller and this driver version PenMount Control Panel Eg I Penmount Control Panel version 1 0 0 71 Installed Device s Device 0 PenMount 5000 USB Support E mail penmauntcieseed ret ty Support Website http penmaunt corn bw PenMount Monitor Menu Icon The PenMount monitor icon PM appears in the menu bar of Windows XP 2003 Vista 7 system when you turn on the PenMount Monitor in the PenMount Utilities pm 4 04 The PenMount Monitor has the following functions Control Panel Right Button Pen Stabilizer Exit ADP 1XX5A User Manual 30 Control Panel Open Control Panel Windows Setting Beep function for each device Right Button When you select this function a mouse icon appears in the right bottom of the screen D Click this icon to switch between Right
Download Pdf Manuals
Related Search
Related Contents
balanza digital nahita nahita digital balance balance digital Special Declaration - Highlight Electronics 1000 Watt • 2500 Watt • 4500 Watt USER MANUAL - Kramer Electronics Japan Homepage Vodafone X3-02 White HP ProBook 4540s Sharp LC-50LE440U LED TV ConductimètrePierron Operating Instructions Type 2030, 2031, 2031 K Copyright © All rights reserved.