Home

Worldwide Lighting W83001G72 Instructions / Assembly

image

Contents

1. and in the orientation depicted Refer to the parts list to avoid confusion between parts The part Numbers coincide CAUTION 1 Rated 110v 130v 60Hz bulb E12 40W maximum 2 Care Should be taken to avoid damage to the surface of lighting and wire wearing gloves is recommended when installing 3 Connect black or red wire of the lighting to live wire and white or blue wire to neutral wire and double colored or bare copper wire to ground wire 4 Never install lighting on damp ceiling the room should be dry and well ventilated 5 Keep lighting away from acid alkali and other corrosive chemical or gas clean the lighting with Clean soft cloth only 6 Installation must be carried out by qualified electrician only T Disconnect the power before installing Ceaning and replacing lighting 8 Never cover the lighting when power is connected 9 Firmness must be secured when installing ceiling tube chain pipe and other connecting parts 10 Care should be taken to avoid damage when installing glass parts 11 All electrical components must be installed by a licensed electrician and in accordance with the National Electrical Code and the appropriate local electrical codes Make sure that the elecrtrical supply to the chandellier is turned off at the main fuse or circuit breaker before doing any installation Worldwide lighting shall not be responsible for unprofessional wiring Crystal Dressing Diagram When dressing the chandelier w
2. K NUTS CONNECTING CRYSTAL COVER SCREW COLLAR Install scrolls into washer with screws provided Install arms into large arm washer Line up holes in arms with dimple in washer Use lock washer and nut tk secure arms in place Connect bare ground wires in each arm to bare ground wire in center columu Use electrical tape to secure wire nuts NO MORE THAN 5 WIRESPER WIRE NUT Sufficient quantities of jumper wires and wire nuts are provided CEILING Connect white arm wires to neutral column wire ribbed or marked is neutral Connect blak arm wires to power wire in column Carefully press wires as cloes as possible to the underside of washer 10 Attach lighe assembly with lock washer adn coupling with _ RUNNING THREAD pipe Install 5 C7 bulbs Attach glass assembly with rosette and round nut CEILING LINK 11 Install bobeches and bulbs connect power adn test the fixture BEFORE trimming If any of the bulbs do NOT light DISCONNECT POWER Double check the wire connections CANOPY hA VA VAVAVAVAVAVAVAVAVAVAVAVAVAV aug ROO WARNING CONTENTS ARE FRAGILE HANDLE WITH CARE The metal frame and crystal components of this chandelier are very delicate Please excersise extreme Caution during unpacking and installation WARNING After passing the main eiectrical wire through the 10mm pipe and connecting the pipe to the main body top connector place all remaining pieces as shown in nurmerical order
3. W 83001C72 D72 H60 L48 1 We are dedicated to providing the finest quality crystal chandelier for our customers Our master craftsmen and designer pride themselves on their attention to detail prompt efficient service is our priority Enclosed are detailed instructions on how to properly install your chandelier Please read all instructions carefully and thoroughly If you have any questions please fell free to call our toll free DHANDELIER HOTLINE AT 1 855 411 8999 C US Crystal Dressing Instructions CANOPY PARTS LIST When dressing the chandelier with the crystals please remember to wear either rubber or cotton Existing Electrical Box gloves So as to prevent any damage or smudging on the crystals Al A2 B C D2 D1 Rima g 16mmX5 16mmX7 Le 3 16mmX11 J 16mmX1 aie V Crossbar Screws 4 i E2 F Fl D3 El g 2 16mmX9 16mmX6 p 16mmX11 16mmX9 16mmX5 an A 4 4 Crossbar Screws x 2 not srpplied G Gl 16mmX7 q TEZEK RRA t4 EEK 4 4 HI I Il 16mmX1 16mmX1 18mmX1 Eai 16mmX13 t 16mmX11 i 16mmX12 16mmX8 4 j Glass Saucer Jl 16mmX18 i K L 2 16mmX15 16mmX6 2 16mmX16 3 16mmX17 i Chains 4 4 4 60mm Wire Connector i Shrinkable tube i F Cable tie 3 rings rings ngs Ground Wire TH o oo as Kap Boel Boa be Ro co eo N RTO CANOPY INSTALLATION DIAGRAM Frame Parts List GROUND WIRE LARGE HEXNUTS LOC
4. ing 3 Connect black or red wire of the lighting to live wire and white or blue wire to neutral wire and double colored or bare copper wire to ground wire 4 Never install lighting on damp ceiling the room should be dry and well ventilated 5 Keep lighting away from acid alkali and other corrosive chemical or gas clean the lighting with Clean soft cloth only 6 Installation must be carried out by qualified electrician only 7 Disconnect the power before installing Ceaning and replacing lighting 8 Never cover the lighting when power is connected 9 Firmness must be secured when installing ceiling tube chain pipe and other connecting parts 10 Care should be taken to avoid damage when installing glass parts 11 All electrical components must be installed by a licensed electrician and in accordance with the National Electrical Code and the appropriate local electrical codes Make sure that the elecrtrical supply to the chandellier is turned off at the main fuse or circuit breaker before doing any installation World wide lighting shall not be responsible for unprofessional wiring Frame Assembly Instructions Installation Please read all instructions carefully Before you proceed to install make sure that the power supply is turned off and remains off until installation is complete please note that each part has been assigned a number please proceed in a numerical order Assembly Lamp Body 01 Install Crossbar wi
5. ith the crystals please remember to wear either rubber or cotton gloves So as to prevent any damage or smudging on the crystals Frame Assembly Diagragram CANOPY INSTALLATION INSTRUCTIONS MAKE SURE POWER IS DISCONNECTED ttach washer to supporting member in ceiling sufficient to upport weight of fixture lip screw collar prismatic cover and metal canopy over hain Determine the suspension length of the fixture adn ut if necessary Use two connecting links to attach chain to handelier loop and ceiling loop nsert stem wire through chain and ceiling loop Connece ires Fixture MUST be grounded heck distance from ceiling to loop to assure canopy assembly will be fiush against ceiling Attach canopy to ceiling with screw collar Qas maaa Nn gt WARNING CONTENTS ARE FRAGILE HANDLE WITH CARE The metal frame and crystal components of this chandelier are very delicate Please excersise extreme Caution during unpacking and installation WARNING After passing the main eiectrical wire through the 10mm pipe and connecting the pipe to the main body top connector place all remaining pieces as shown in nurmerical order and in the orientation depicted Refer to the parts list to avoid confusion between parts The part Numbers coincide CAUTION 1 Rated 110v 130v 60Hz bulb E12 40W maximum 2 Care Should be taken to avoid damage to the surface of lighting and wire wearing gloves is recommended when install
6. th J Box and then Fixed the Canopy 03 Join the Lamp Body 01 and crossbar 02 with Chains 04 ake sure the positive and negative charges of wire and Lamp Body 02 match correctly screw the connect point with the junction cap Make sure the main wire is enough long and keep the rest wire in the 4 J box As the crystal pressing instruction hang the crystal parts Install lighting Source

Download Pdf Manuals

image

Related Search

Related Contents

Philips MotoVision Automotive headlighting lamp 12342MVS1    MODE D`EMPLOI PICASSA  MAGNETIC FIELD MAPPING SYSTEM MMS-1-R - USER`S MANUAL -  Vogel's PTS 1216 TabLock for iPad mini, home button hidden    XFX PV-T84G-YDQ3 GeForce 8600 GTS graphics card  ベゴ フォルナックスT  descrição do aparelho conselhos instruções de  GWH2 / 1052103 GWH3 / 1053103  

Copyright © All rights reserved.
Failed to retrieve file