Home

Moxa EDS-P206A-4PoE

image

Contents

1. Rx NOTE Ifthe PD only supports MDI mode V V V V for pins 1 2 3 6 choose a cross over Ethernet cable to connect the PD and the EDS switch If the PD only supports MDI X mode V V V V for pins 1 2 3 6 choose a straight through Ethernet cable between the PD and the EDS P206 4PoE switch 100BaseFX Ethernet Port Connection The concept behind the SC ST port and cable is straightforward Suppose you are connecting devices I and II contrary to electrical signals optical signals do not require a circuit in order to transmit data Consequently one of the optical lines is used to transmit data from device I to device II and the other optical line is used transmit data from device II to device I for full duplex transmission Remember to connect the Tx transmit port of device I to the Rx receive port of device II and the Rx receive port of device I to the Tx transmit port of device II If you make your own cable we suggest labeling the two sides of the same line with the same letter A to A and B to B as shown below or Al to A2 and B1 to B2 SC Port Pinouts SC Port to SC Port Cable Wiring Cable Wiring 10 ST Port Pinouts ST Port to ST Port Cable Wiring Tx Cable Wiring AN ATTENTION This is a Class 1 Laser LED product To avoid causing serious damage to your eyes do not stare directly into the Laser Beam Redundant Power Inputs Both power inputs can be connected simultaneou
2. front panel are used to connect to Ethernet enabled devices Below we show pinouts for both MDI NIC type ports and MDI X HUB Switch type ports and also show cable wiring diagrams for straight through and cross over Ethernet cables MDI Port Pinouts MDI X Port Pinouts 8 pin RJ45 eR PoE 10 100BaseT X Ethernet Port Connection PoE 10 100BaseT X ports located on the EDS switch s front panel are used to connect to PoE enabled devices The pinout follows the Alternative A MDI X mode of 802 3af at standards Please see the details in the following table PoE Port Pinout 8 pin RJ45 NOTE According to IEEE 802 3af at standards the PD shall be implemented to be insensitive to the polarity of the power supply and shall be able to operate per MDI mode and MDI X mode However some PDs only support MDI mode or MDI X mode only The following figure shows how to select the correct cable between the PD and EDS P206A 4POE Straight Through Cable Switch Port E NIC Port ES RJ45 Plug Pin 1 RJ45 RJ45 Connector 3 Cable Wiring Connector Tx 3 3 Rx Tx 6 6 Rx Rx 1 1 Tx Rx 2 2 Tx RJ45 8 pin to RJ45 8 pin Cross Over Cable Wirin Switch Port Cross Over Cable Switch Port NIC Port NIC Port RJ45 Plug Pin 1 RJ45 RJ45 Connector Cable Wiring Connector Rx Tx 3 1 Rx Tx Rx Tx 6 2 Rx Tx Tx Rx 1 3 Tx Rx Tx Rx 2 6 Tx
3. in appearance to the EDS P206A 4Po0E M SC ST AU N EDS P206A EDS P206A 4PoE M ST 4PoE M SC Front Panel View Top Panel View BW N Rear Panel View N OON Grounding screw Terminal block for power input P1 P2 Heat dissipation vents DIP switches Power input P1 LED Power input P2 LED PoE LED 10 100BaseT X port TP port s 10 100 Mbps LED Model name 100BaseFX port FX port s 100 Mbps LED Screw hole for wall mounting kit DIN Rail kit EDS P206A 4P0E MM SC ST Panel Layouts NOTE The EDS P206A 4P0E SS SC ST are identical in appearance to the EDS P206A 4PoE MM SC ST N A EDS P206A 4PoE MM ST Front Panel EDS P206A 4PoE MM SC View afek oH Aci Top Panel View AUO N Rear Panel View N OON Grounding screw Terminal block for power input P1 P2 Heat dissipation vents DIP Switches Power input P1 LED Power input P2 LED PoE LED 10 100BaseT X port TP port s 10 100 Mbps LED Model name 100BaseFX port FX port s 100 Mbps LED Screw hole for wall mounting kit DIN Rail kit Mounting Dimensions unit mm 20 23 5 DIN Rail Mounting The aluminum DIN Rail attachment plate should already be fixed to the back panel of the EDS when you take it out of the box If you need to reattach the DIN Rail attachment plate make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 STEP 2 In
4. operation of the network such as the occasional multi cast packet are forwarded to all ports The EDS operates in the store and forward switching mode which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network Switching and Address Learning The EDS has an address table that can hold up to 1024 addresses which makes it suitable for use with large networks The address tables are self learning so that as nodes are added or removed or moved from one segment to another the EDS automatically keeps up with new node locations An address aging algorithm causes the least used addresses to be deleted in favor of newer more frequently used addresses To reset the address buffer power down the unit and then power it back up gt lt Auto Negotiation and Speed Sensing All of the EDS s RJ45 Ethernet ports independently support auto negotiation for speeds in the 10BaseT and 100BaseTX modes with operation according to the IEEE 802 3u standard This means that some nodes could be operating at 10 Mbps while at the same time other nodes are operating at 100 Mbps Auto negotiation takes place when an RJ45 cable connection is made and then each time a LINK is enabled The EDS advertises its capability for using either 10 Mbps or 100 Mbps transmission speeds with the device at the other end of the cable expected to advertise in a similar manner Depending on what type of device is conne
5. EDS P206A 4PoE Series Hardware Installation Guide Moxa EtherDevice Switch Second Edition April 2011 MOXA 2011 Moxa Inc All rights reserved P N 1802002060011 Overview The EDS P206A 4PoE series industrial Ethernet switches are entry level industrial 6 port PoE Ethernet switches that support IEEE 802 3 IEEE 802 3u and IEEE 802 3x with 10 100M full half duplex MDI MDIX auto sensing IEEE 802 3af and IEEE 802 3at The EDS P206A 4PoE series provides 24 48 VDC redundant power inputs that can be connected simultaneously to a live DC power source The switches are available with a standard operating temperature range from O to 60 C or with a wide operating temperature range from 40 to 75 C and their IP30 metal housing makes them rugged enough for any harsh industrial environment To provide greater versatility for use with applications from different industries the EDS P206A 4PoE switches also allow users to enable or disable broadcast storm protection with DIP switches on the outer panel The EDS P206A 4PoE switches can be easily installed on a DIN Rail or in distribution boxes The DIN Rail mounting capability and IP30 metal housing with LED indicators make the plug and play EDS P206A 4PoE switches reliable and easy to use NOTE Throughout this Hardware Installation Guide we use EDS as an abbreviation for Moxa EtherDevice Switch EDS Moxa EtherDevice Switch Package Checklist Your EDS is shipped with
6. I X Connection The Auto MDI MDI X function allows users to connect the EDS s 10 100BaseTX ports to any kind of Ethernet device without needing to pay attention to the type of Ethernet cable being used for the connection This means that you can use either a straight through cable or cross over cable to connect the EDS to Ethernet devices Dual Speed Functionality and Switching The Moxa EtherDevice Switch s 10 100 Mbps switched RJ45 port auto negotiates with the connected device for the fastest data transmission rate supported by both devices All models of Moxa EtherDevice Switch are plug and play devices so that software configuration is not required at installation or during maintenance The half full duplex mode for the switched RJ45 ports is user dependent and changes by auto negotiation to full or half duplex depending on which transmission speed is supported by the attached device Switching Filtering and Forwarding Each time a packet arrives at one of the switched ports a decision is made to either filter or forward the packet Packets with source and destination addresses belonging to the same port segment will be filtered constraining those packets to one port and relieving the rest of the network from the need to process them A packet with destination address on another port segment will be forwarded to the appropriate port and will not be sent to ports where it is not needed Packets that are used in maintaining the
7. cted this will result in agreement to operate at a speed of either 10 Mbps or 100 Mbps If an EDS RJ45 Ethernet port is connected to a non negotiating device it will default to 10 Mbps speed and half duplex mode as required by the IEEE 802 3u standard Specifications IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X and 100BaseFxX IEEE 802 3x for Flow Control IEEE 802 3af for PoE IEEE 802 3at for PoE rocessing Type Store and Forward Flow Control IEEE 802 3x flow control back pressure flow control 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection 100BaseFX ports SC ST connector multi single mode LED Indicators P1 P2 Power 10 100M TP port and 100M fiber port PoE DIP Switch enable disable broadcast storm protection Optical Fiber 100BaseFX Multi mode Single mode Wavelength 1300 nm 1310 nm Max TX 10 dBm 0 dBm Min TX 20 dBm 5 dBm RX Sensitivity 32 dBm 34 dBm Link Budget 12 dB 29 dB 5 kma Typical Distance 4 kmb 40 kmc Saturation 6 dBm 3 dBm using 50 125um 800 MHz km cable using 62 5 125um 500 MHz km cable using 9 125 um 3 5 PS nm km cable Pie he ae Input Voltage 24 48 VDC nput Current 5 5 2 6 A emovable 4 contact terminal block Protection Protection eee ieee use an isolated power supply to standards conform to the UL 508 standard Note We strongly recommend using an isolated power supply with maximum output current of 7 5 A d
8. he EDS 205A 208A downwards as indicated Tighten the four screws for added stability Wiring Requirements WARNING Safety First Turn the power off before disconnecting modules or wires The correct power supply voltage is listed on the product label Check the voltage of your power source to make sure that you are using the correct voltage Do NOT use a voltage greater than what is specified on the product label WARNING Safety First Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment You should also pay attention to the following points e Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately e You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together e Keep input wiring and output wiring separated e We strongly advise labeling the wiring
9. sert the top of the DIN Rail The DIN Rail attachment unit will into the slot just below the stiff snap into place as shown below metal spring Metal Metal Spring Spring DIN Rail DIN Rail To remove the EDS from the DIN Rail reverse Steps 1 and 2 above iG Wall Mounting optional For some applications you will find it convenient to mount the EDS P206A 4PoE on the wall as shown in the following figures STEP 1 Remove the aluminum DIN Rail attachment plate from the EDS P206A 4PoE s rear panel and then attach the wall mount plates as shown in the diagram at the right STEP 2 Mounting the EDS P206A 4PoE on the wall 6 0 mm requires 4 screws Use the switch with wall mount plates lt attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less than 6 0 a mm in diameter and the shafts should be less than 3 5 35mm mm in diameter as shown in the figure at the right NOTE Before tightening the screws into the wall make sure the screw head and shank size are suitable by inserting the screw into one of the keyhole shaped apertures of the wall mounting plates Do not screw the screws in completely leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws STEP 3 Once the screws are fixed in the wall insert the four screw heads through the large parts of the keyhole shaped apertures and then slide t
10. sly to live DC power sources If one power source fails the other live source acts as a backup and automatically supplies all of the EDS s power needs DIP Switch Settings The default setting for each DIP Switch is OFF The following table explains the effect of setting the DIP Switches to the ON positions ON OFF DIP Switch Setting Description o E S Serves no function reserved for future use BSP ON E Enables broadcast storm protection OFF O Disables broadcast storm protection AN ATTENTION To actively update DIP switch settings power off and then power on the EDS LED Indicators The front panel of the EDS switches contains several LED indicators The function of each LED is described in the following table LED Color _ State_ Description _ _ On Power is being supplied to power input P1 P1 AMBER Power is not being supplied to power input off p1 On Power is being supplied to power input P2 P2 AMBER Power is not being supplied to power input P2 10 100 AMBER On TP port s 10 Mbps link is active Blinking Data is being transmitted at 10 Mbps Off On TP port s 100 Mbps link is active Off On On Fx port s 100 Mbps link is active 100M GREEN Blinking Data is being transmitted at 100 Mbps loft Fx port s link is inactive Power is being supplied to Powered Device PoE AMBER PD off Power is not being supplied to Powered Device PD Auto MDI MD
11. the following items If any of these items are missing or damaged please contact your customer service representative for assistance e Moxa EtherDevice Switch e Hardware Installation Guide e Warranty card Features High wattage Power over Ethernet e Up to 30 watts per PoE port e Active circuit protection e Auto disconnection for over voltage or under voltage e Power consumption detection and classification High Performance Network Switching Technology e 10 100BaseT X RJ45 connector L1OOBaseFX SC ST connector multi single mode e 10 100M Full Half Duplex MDI MDIX auto sensing e IEEE 802 3 802 3u 802 3x e Store and Forward switching process type 1K address entries Rugged Design e Redundant dual 24 48 VDC power input e Operating temperature range from O to 60 C or extended operating temperature of 40 to 75 C for T models e IP30 metal housing e DIN Rail or panel mounting capability oe EDS P206A 4PoE Standard Panel Layouts Front Panel View 1 2 3 4 5 6 7 8 9 10 11 Top Panel View 12 AU N Rear Panel View Grounding screw Terminal block for power input P1 P2 Heat dissipation vents DIP switches Power input P1 LED Power input P2 LED PoE LED 10 100BaseT X port TP port s 10 100 Mbps LED Model name Screw hole for wall mounting kit DIN Rail kit EDS P206A 4Po0E M SC ST Panel Layouts NOTE The EDS P206A 4Po0E S SC ST are identical
12. to all devices in the system Grounding the EtherDevice Switch Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices AN ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Wiring the Redundant Power Inputs The top two contacts and the bottom two contacts of the 4 contact terminal block connector on the EDS s top panel are used for the EDS s two DC inputs Top and front views of one of the terminal block connectors are shown here STEP 1 Insert the negative positive DC wires into the V V terminals STEP 2 To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector STEP 3 Insert the plastic terminal block connector prongs into the terminal block receptor which is located on EDS s top panel Front View AN ATTENTION Before connecting the EtherDevice Switch to the DC power inputs make sure the DC power source voltage is stable Communication Connections The EDS P206A 4PoE switches have 6 7 or 8 10 100BaseT X Ethernet ports and 2 1 or O zero 100BaseFX multi single mode SC ST type connector fiber ports 10 100BaseT X Ethernet Port Connection 10 100BaseT X ports located on the EDS s
13. ue to the power de rating issue of the power supply at high operating temperatures Moreover without galvanic isolation between the redundant power inputs of this device the V1 and V2 should use the same voltage Housing Dimensions Weight i DIN Rail Mounting Wall Mounting with optional kit Operating Standard models 0 to 60 C 32 to 140 F Temperature Wide temp models 40 to 75 C 40 to 167 F Storage Temperature Ambient Relative 5 to 95 non condensing Humidity Regulatory Approvals I M FCC Part 15 CISPR EN55022 class A MS EN61000 4 2 ESD Level 3 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 3 EN61000 4 5 Surge Level 3 EN61000 4 6 CS Level 3 EN61000 4 8 Level 5 Shock reefall Vibration Time Period 5 years Details www moxa com warranty Technical Support Contact Information www moxa com support Moxa Americas Moxa China Shanghai office Toll free 1 888 669 2872 Toll free 800 820 5036 Tel 1 714 528 6777 Tel 86 21 5258 9955 Fax 1 714 528 6778 Fax 86 21 5258 5505 Moxa Europe Moxa Asia Pacific Tel 49 89 3 70 03 99 0 Tel 886 2 8919 1230 Fax 49 89 3 70 03 99 99 Fax 886 2 8919 1231 14

Download Pdf Manuals

image

Related Search

Related Contents

    Descargar ficha.  Atom user manual  PDF-Bedienungsanleitung - KOMETEC, Online  Panasonic DP-8045 Specification Sheet  #99-04-21-005E: Transfer Case Shudder (Flush and  MANUAL TÉCNICO DE MENSAGEM - Integração das Clearings da  PRODUCT LIST - SmartLink International  PN-V601 Operation-Manual GB FR ES DE RU  