Home

User manual

image

Contents

1. User manual for TA electrical commode Note Before using this equipment read this manual and save for future reference Application TA commode is intended to help a person to an upright position from a normal toilet The commode shall be placed on a plane smooth surface with an inclination of max 3 degrees Warning TA commode with wheels accessories is not intended to be used for transfer of a person The wheels are only intended to be used when moving the commode Note TA commode is not intended to be used as a shower lift Exposure to heavy humidity may damage and cause malfunction of the hand control the lifting device and the electronics Before use 1 Adjustment of the commode Remove the existing toilet seat Place the commode over the toilet and adjust the four adjustable supports to a level where the clearance between the toilet seat rim of the commode and the toilet is min 10 mm Warning To avoid tilting the commode shall be adjusted so the toilet seat rim is at horizontal level and the commode is not rocking If the base of the toilet is longer than usual the lower frame can be adjusted by 2 5 or 5 cm in relation to the lifting device with the toilet seat see separate installations drawing The distance between the armrests can be adjusted by loosening the screws that lock the armrests in position and push the armrests in or out until desired width Fix the screw after adjusting Warning When folding up the armr
2. ctuator handcontrol Serial no Production year 2009 The above machinery is hereby declared to be in accordance with the essential demands of the Proclamation for Medical Equipment Ministry of Health Proclamation No 734 of August 10th 1994 EU s Directive on Medical Equipment 93 42 E F Signature Faxe Denmark the Torben Andersen TA Service Ltd User manual for TA commode Page 5 of 8 05 GINNERUP of 8 TA Service Ltd LIFTING TO UPRIGHT LOFT TIL STAENDE Keep knees at 90 degree angle Sid med kn ene i 90 grader vinkel Start lifting and move forwards keep feet on ground Begynd l ft og bevasg fremad lad f dderne hvile p jorden Lift until legs are stretched 7 Loft til benene er strakt ud User manual for TA commode Page 8 of 8
3. est closest to the vertical lifting device a risk of squeezing parts of the body may occur 2 Batteries The batteries of anew commode should always be fully charged before use see paragraph 2 Charging Use 1 Lifting If the commode is equipped with wheels accessories all four wheels shall be locked when the commode is in use Warning TA commode with wheels is not intended to be used for transfer of a person The wheels are only intended to be used when moving the commode Open the lid of the toilet seat up against the supporting pin which keeps the lid in place when commode is used To be continued TA Service Ltd User manual for TA commode Page 1 of 8 1 Lifting continued Note The supporting pin is not intended to be used as a back support but only to keep the lid in place Foldable armrests facilitate the transfer to and from wheel With armrests in upright position the commode takes up less space Warning When folding up the armrest closest to the vertical lifting device a risk of squeezing parts of the body may occur Adjust the commode up or down by pressing the buttons on the hand control Warning Parts of the body may be squeezed between the toilet and the toilet seat rim of the commode Caution shall be taken when lowering the commode in the minimum seat height range The use of splashguard accessory may decrease the risk of squeezing Warning Forward stability is decreased when the vertical
4. lifting device is lifted to its maximum height Caution shall be taken when mounting and dismounting the commode at maximum seat height The hand control may be placed in the fitting at the armrest or hung at an appropriate place in the room 2 Charging The batteries should be recharged regularly An acoustic warning signal buzzer will sound when batteries are discharged to about 50 Connect the supplied charger to the charger plug on the hand control and to a 220V wall socket Remember to switch on the wall socket Leave the charger connected for 24 hours Note Never leave the charger connected full time When the batteries have been changed they too should be fully charged before use 3 Maintenance The white frame and the armrests may be cleaned with water and a common detergent Warning The black hand control lifting motors and the black control box should only be cleaned with a damped washcloth with a mild detergent as they are not water resistant in the standard version of TA commode s After 3 years following parts should be checked e The bolts at the base of the vertical lifting device shall be tightened up to 5 kpm e The bolts at both ends of the lifting motor shall be tightened up to 5 kpm After 6 years following parts should be checked e The sliding guides inside the vertical lifting device for wear and tear e The lifting motor The inspection shall be executed only by authorised personnel from the distributor o
5. r a specialist authorised by TA Service Ltd Note TA Service Ltd cannot be rendered liable for defects or accidents due to maintenance executed by unauthorised personnel TA Service Ltd User manual for TA commode Page 2 of 8 4 Troubleshooting Problem____________ Possiblefault Action No lifting effect Before calling authorised personnel please note and describe the fault as accurate as possible This will make it easier to identify the fault Note Only original spare parts from TA Service Ltd shall be used for maintenance and repair TA Service Ltd cannot be rendered liable for defects or accidents due to repair executed by unauthorised personnel nor due to use of batteries or other spare parts not delivered by TA Service Ltd Accessories Wheels 75 mm stainless with individual brakes 4 pcs Holder for toilet roll Splashguard Specifications User weight 100 kg Seat height 48 93 cm Lifting interval 40 cm Adjustment interval supports 5 cm Seat width 37 cm Seat depth 42 cm Armrest height 22 cm Distance between armrests 49 cm Total width 61 cm Total height 92 137 cm Weight 29 kg Batteries 2x12V maintenance free Battery capacity Approx 60 liftings of 60 kg for each charging Charging alarm Acoustic Materials Seat Urea plastic Frame Powder coated stainless steel ISO Classification ISO 09 12 21 Art No 30000 TA electrical commode is manufactured and tested in accordance with the international
6. standards ISO 10535 1998 and prEN 12182 1998 TA Service Ltd User manual for TA commode Page 3 of 8 Spare parts No see drawing Reference Drawing No Batteries 2 pcs 1 Charger 250 mA 24v 2 Wheels 75 mm stainless 4 pcs Accessories 3 Lifting motor 4 Inner lifting device right 5 Inner lifting device left 6 Rubber plug for the support set of 4 pcs 7 Toilet seat Pressalit 2000 8 Gliding bushing lower set of 2 pcs 9 Gliding bushing upper set of 8 pcs 10 Adjustable support with rubber plug 4 pcs 11 Lower frame right 12 Lower frame left 13 Armrest with pad 2 pcs 14 Pads for armrests 2 pcs Fitting for the hand control 15 Hand control 16 Toilet seat rim right 17 Toilet seat rim left 18 Control CB08 19 TA Service Ltd User manual for TA commode Page 4 of 8 Agreement declaration In accordance with the Proclamation for Medical Equipment The Ministry of Health Proclamation No 734 of August 10th 1994 EU s Directive on Medical Equipment 93 42 EQF Producer TA Service Ltd Orupgade 32 B Orup DK 4640 Faxe Denmark Tel 45 56725777 Fax 45 56725776 Product name TA electrical commode ISO Classification ISO 09 12 21 Art no 30000 Rightside actuator handcontrol 30049 Leftside actuator handcontrol 30050 Wallhanging rightside actuator handcontrol 30056 Wallhanging leftside actuator handcontrol 33000 Waterresistant rightside actuator handcontrol 33014 Waterresistant leftside a

Download Pdf Manuals

image

Related Search

Related Contents

TDSHーBA 束芝LEDダゥンラィト取扱説明害  Korg AmkII User's Manual  コンパクト多機能トイレパック オストメイト対応トイレパック  Manuale Utente User Manual DMX SOFTWARE  VC-500IJ 取扱説明書_59-1315  Fountain Cellar FCL051 Use and Care Manual  

Copyright © All rights reserved.