1. CyberPower Reliability Quality Value User s Manual OR1500PFCRT2U OR2200PFCRT2U OR2200PFCRT2Ua K01 0000206 00 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate your UPS CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery Ensure the input power is removed before servicing the batteries There are no user serviceable parts inside except for the battery CAUTION Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected CAUTION The UPS must be connected to an AC power outlet with fuse or circuit breaker protection Do not plug into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the unit CAUTION To avoid electric shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION To reduce the risk of fire connect only to a circuit provided with 20 OR1500
2. system is receiving from the utility wall outlet The UPS is designed through the use of automatic voltage regulation to continuously correct co ei I SI output voltage to connected equipment to a safe 110 120 voltage output range In the event of a complete power loss severe brownout or over voltage the UPS relies on its internal battery to supply consistent ul 110 120 output voltage The INPUT voltage meter can be used as a Lt eee diagnostic tool to identify poor quality input power 2 OUTPUT voltage meter This meter measures in real time the AC The LCD display indicates a variety of UPS voltage that the UPS system is providing to the computer such as operational conditions All descriptions apply when the UPS is plugged into an AC outlet normal line mode AVR mode and battery backup mode Note The arid turin arte the UPS ion belies OUTPUT voltage meter shows the status of the battery backup outlets 3 ESTIMATED RUN TIME This displays the run time estimate of the UPS with current battery capacity and load 4 NORMAL icon This icon appears when the UPS is working under normal conditions 5 BATTERY icon During a severe brownout or blackout this icon appears and an alarm sounds two short beeps followed by a pause to indicate the UPS is operating from its internal batteries During a prolonged brownout or blackout the alarm will beep rapidly every 1 2 second and the BATT CAPACITY meter shows one 20 capacity se
3. Systems about The battery is worn out replacement batteries at tech cyberpowersystems com Contact CyberPower Systems at VISCHABICAWPIODIH tech cyberpowersystems com Connect the USB serial cable to the UPS The USB serial cable is not unit and an open USB serial port on the connected back of the computer You must use the cable that came with the unit l Check the back of the computer for an TONE AMS Business The USB serial cable is additional USB serial port Move the cable Edition is inactive all connected to the wrong port to this port Icons are gray Th ti i idi Shutdown your computer and turn the UPS rain PERSO off Wait 10 seconds and turn the UPS back on This should reset the unit cable that came with the unit unit for the software Additional troubleshooting information can be found under Support at www CPSww com The UPS will not turn on TECHNICAL SPECIFICATIONS On Battery Output A Voltage 120Vac 5 Transfer Time 4ms Typical Max Load for UPS Outlets 8 Outlets 1500VA 900W 2000VA 1320W 2200VA 1320W Max Load for Full Time Surge Protection outlets 12 5 Amps 16 7 Amps 18 3 Amps 8 Outlets On Battery Output Wave Operating Temperature 32 F to 104 F 0 C to 40 C Operating Relative 6 i Humidity 0 to 90 non condensing iaw a Net Weight 55 1lbs 25kg 59 3lbs 26 9kg 60lbs 27 2kg Batterv Tvpe 12V 7Ah 12V 8 5Ah 12V 8 5Ah y YP RBP433 CyberPower RBP435 CyberPo
4. environmentally friendly on the market today LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE Read the following terms and conditions carefully before using the CyberPower OR1500PFCRT2U OR2200PFCRT2U OR2200PFCRT2Ua the Product By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty and Connected Equipment Guarantee together referred to as this Warranty If you do not agree to the terms and conditions of this Warranty you should return the Product for a full refund prior to using it Who is Providing this Warranty CyberPower Systems USA Inc CyberPower provides this Limited Warranty What Does This Warranty Cover This warranty covers defects in materials and workmanship in the Product under normal use and conditions lt also covers equipment that was connected to the Product and damaged because of the failure of the Product What is the Period of Coverage This warranty covers the Product for three years and connected equipment for as long as you own the Product Who Is Covered This warranty only covers the original purchaser Coverage ends if you sell or otherwise transfer the Product How Do You Get Warranty Service 1 Before contacting CyberPower identify your Product model number the Purchase Date and each item of Connected Equipment E G Computer tower Computer Monitor Ink Jet Printer Cable Modem etc 2 Visit our web site at ht
5. power demands of these devices may overload and damage the unit 3 To protect a fax phone or modem connect a telephone cable or network cable from the wall jack outlet to the IN jack of the UPS Connect a telephone cable or network a cable from the OUT jack of the UPS to a fax machine telephone modem or network Lon devices 4 Plug the UPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment D with large electrical demands e g air conditioner copier etc The warranty prohibits a 2 the use of extension cords outlet strips and surge strips A t 5 Press the power switch to turn the unit on The Power On indicator light will illuminate and the unit will beep If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Make sure the circuit breaker is depressed and then turn the UPS on 6 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 7 To store the UPS for an extended period cover it and store with the battery fully charged While in storage recharge the battery every three months to ensure battery life 8 To use PowerPanel Business Edition software connect the serial cable to the serial port or the USB port on both
6. CyberPower Systems USA Inc 4241 12 Ave E STE 400 Shakopee MN 55379 call us at 877 297 6937 or send us an e mail message at clains cyberpowersystems com All rights reserved Reproduction without permission is prohibited 13
7. PFCRT2U and OR2200PFCRT2U or 30 0R2200PFCRT2Ua amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION The UPS is suitable for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect the operation and safety of life support equipment medical applications or patient care DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire or electric shock do not use with or near an aquarium Condensation from the aquarium can cause the unit to short out INSTALLING YOUR UPS SYSTEM INTRODUCTION Thank you for selecting a CyberPower Systems UPS product This UPS is designed to provide unsurpassed power protection operation and performance during the lifetime of the product UNPACKING Inspect the UPS upon receipt The box should contain the following a UPS unit x 1 b User s manual x 1 c Rack mount brackets x 2 d Vertical stands x 2 e Telephone cable x 1 f Emergency Power Off cable gray x 1 g PowerPanel Business Edition software CD x 1 h Serial cable x 1 i USB A B type cable x 1 j Warranty registration card x 1 SUPPORTS PFC POWER SUPPLIES This CyberPower UPS system supports High Efficiency powe
8. ate disrupting and damaging effects of momentary less than 1ms voltage spikes or impulses from lightning or other power transients If it can be shown that a voltage spike lasting longer than 1ms has occurred the occurrence will be deemed outside the rated capabilities of the Product and the Limited Warranty is void CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following 1 Lossofordamageto data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10T Ethernet lines when properly installed and connected This exclusion applies for example to fluctuations in data transmission 12 or reception by CATV or RF transmission or fluctuations or by transients in such transmission Damage from any circumstance described as excluded above with respect to the Product Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse misuse or alteration of either the product or the Connected Equipment CyberPower excludes any liability for personal injury under the Limited Warranty and Connected Equipment Guarantee CyberPower excludes any liability for direct indirect
9. ay screen without changing any settings The Mode details are described in the following table Press Display button to choose the mode you prefer When the mode is chosen press 8 seconds to save the setting If the Display button is not touched for 3 minutes you will leave Setup Mode and return to UPS LCD Status Display screen Function Setup Mode Setup Icon Description ssa DIC Low This unit is least sensitive to 86 1 42Vac Tre Ca ESTIMATE RUN_TIME voltage fluctuations tti II Sensitivity si This is the default setting 88 139Vac L INPUT nn ee Cleric l Hes FE eld High This unit is most sensitive to 90 136Vac IU Ca EE voltage fluctuations cere ll INPUT UTPUT ESTIMATE RUN_TIME On ud The LCD is always on whether or j Z m not the LCD button is pressed In Line Mode if the LCD display LCD Always On rire button is not touched for 1 minute ma Dina very the UPS will enter Sleeping Mode Off Ill The LCD will not appear until the ba h nl hal display button is pressed In Battery Mode the LCD is always on The Self Test function is on In Line Mode the UPS will switch to On battery mode to simulate the power failure condition In Battery Self Test Mode the UPS has no action INPUT OUTPUT ESTIMATE RUN_TIME Off CUI Mm The Self Test function is off The i iL UPS has no action Inni Ci Gc ESC N A Return to the LCD Status Display
10. e OR1500PFCRT2U CyberPower RBP435 for the OR2200PFCRT2U and OR2200PFCRT2Ua 2 CAUTION Risk of Energy Hazard 12 V maximum 7 for the OR1500PFCRT2U or 8 5 for the OR2200PFCRT2U and OR2200PFCRT2Ua Ampere hour battery Before replacing batteries remove conductive jewelry such as chains wrist watches and rings High energy conducted through these materials could cause severe burns 3 CAUTION Do not dispose of batteries in a fire The batteries may explode 4 CAUTION Do not open or mutilate batteries Released material is harmful to the skin and eyes It may be toxic CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS BATTERY REPLACEMENT PROCEDURE Remove the three retaining screws of the cable protection cover then remove the cover Remove the right side front panel Disconnect the black and red cable Insert the new battery pack Assemble the screws cover cable and front panel in the reverse sequence of above steps Recharge the unit for 4 8 hours to ensure the UPS performs expected runtime Remove the four retaining screws REMINDER Batteries are considered HAZARDOUS WASTE and must be disposed of properly Most retailers that sell lead acid batteries collect used batteries for recycling as required by local regulations DEFINITION FOR ILLUMINATED LCD INDICATORS 1 INPUT voltage meter This meter measures the AC voltage that the UPS
11. e the Product If the Product is defective in material or workmanship CyberPower will repair or replace it at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required If it appears that our Product failed to protect any equipment plugged into it we will also send you forms for making your claim for the connected equipment We will repair or replace the equipment that was damaged because of the failure of our Product or pay you the fair market value NOT REPLACEMENT COST of the equipment at of the time of the damage We will use Orion Blue Book or another a third party valuation guide or eBay craigslist or other source to establish that amount Our maximum liability is limited to 200 000 for the OR1500PFCRT2U 250 000 for the OR2200PFCRT2U and OR2200PFCRT2Ua Who Pays For Shipping We pay when we send items to you you pay when you send items to us What isn t covered by the warranty 1 This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records or the reinstallation of software 2 This Warranty does not cover or apply to misuse modification operation or storage outside environmen
12. from the outlet and have an electrician verify the outlet is properly wired The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet 12 Coax Cable DSS Surge Protection The Coax Cable DSS surge protection ports will protect any cable modem CATV converter or DSS receiver 13 Serial Port The serial port allows connection and communication between the UPS and the computer 14 EPO Emergency Power Off Port Use the provided gray cable to connect to a special EPO contact switch Follow the appropriate circuit diagram below to wire the cable to your EPO configuration The EPO remote switch is a switch installed in an outside area connected to the unit via the Emergency Power Off cable In case of an emergency it can be used to immediately cut off power from the UPS OPTION 1 USER SUPPLIED NORMALLY CLOSED SWITCH 4 5 JUMPER N O EPO SWITCH RJ11 PLUG NO CONNECTION BATTERY REPLACEMENT REPLACING THE BATTERY Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery CAUTION Servicing of the battery should only be performed by trained personnel familiar with batteries and their precautions For more information on battery replacement contact your dealer or call the number on this manual Replacement of batteries located in an OPERATOR ACCESS AREA 1 When replacing batteries replace with the same number of the following battery CyberPower RBP433 for th
13. gment shaded The capacity depends on how much load added and the runtime left You can setup the Low Battery Threshold through PowerPanel Business Edition software to indicate the UPS s batteries are nearly out of power You should save files and turn off your equipment immediately or allow the software to shut the system down 6 AVR Automatic Voltage Regulation icon This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power This is a normal automatic operation of your UPS and no action is required on your part 7 SILENT MODE icon This icon appears whenever the UPS is in silent mode The buzzer does not beep during silent mode until the battery reaches low capacity 8 OVER LOAD icon This icon appears and an alarm sounds to indicate the battery supplied outlets are overloaded To clear the overload unplug some of your equipment from the battery supplied outlets until the icon turns off and the alarm stops 9 FAULT icon This icon appears if there is a problem with the UPS Contact CyberPower Systems at tech cyberpowersystems com for further help and support F01 Battery Mode or Line Mode Overload fault F02 Battery Output Short fault F03 Charger Fault F04 Internal Fault 10 BATT CAPACITY meter This meter displays the approximate charge level in 20 increments of the UPS s internal battery During a blackout or severe brownout the UPS switches to battery power the BATTERY ic
14. olts or exceeds 140 volts the units automatically switch to battery back up power HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Ensure that the equipment plugged into the outlet does not exceed the UPS unit s rated capacity 1500VA 900W for OR1500PFCRT2U 2000VA 1320W for OR2200PFCRT2U and 2200VA 1320W for OR2200PFCRT2Ua If the rated capacities of the unit are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your computer system will require It is suggested that the load placed on the battery outlets not exceed 80 of the unit s capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However recharging the battery for at least 8 hours is highly recommended to ensure that the battery s maximum charge capacity is achieved A loss of charge may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet 2 With the UPS unit turned off and unplugged connect your computer monitor and any other peripherals requiring battery backup into the battery power supplied outlets For pluggable equipment the socket outlet shall be installed near the equipment and shall be easily accessible DO NOT plug a laser printer paper shredder copier space heater vacuum sump pump or other large electrical devices into the UPS The
15. on appears and the charge level decreases 11 LOAD CAPACITY meter This meter displays the approximate output load level in 20 increments of the UPS battery outlets Advanced LCD Functions Setup There are advanced LCD functions that can be setup through LCD Display button 1 Mute Enable or disable any audible alarm caused by an event 2 Sensitivity Control the sensitivity of the UPS to switch to Battery Mode by selecting UPS shutdown voltage range The higher the sensitivity the easier the UPS will switch to Battery Mode 3 LCD Always On Keep the LCD always lit 4 Self Test Perform a test in Line Mode to test Battery Mode function It will return to Line Mode after the test is completed 5 ESC Leave setup mode without changing any settings and return to LCD status display screen For the Mute function press Display button for 2 seconds to enable or disable audible alarm When you enable audible alarm the Silent icon is not lit When you disable audible alarm the Silent icon is lit L PT For the Sensitivity LCD Always On Self Test and ESC functions press Display button for 8 seconds to enter Function Setup screen Press Display button once to choose between Sensitivity LCD Always On Self Test and ESC Functions When the function is chosen press 2 seconds to enter Mode Setup screen or If the function you select is ESC press 2 seconds and you will leave the Function Setup screen and return to LCD 7 Status Displ
16. ons and messages For more information please review the Definitions for Illuminated LCD Indicators section below 4 LCD function selection switch The switch can be used to select the LCD display contents including input output voltage and estimated run time etc 5 8 Full Time Battery Powered and Surge Protected Outlets The unit has eight battery powered surge suppression outlets for connected equipments to ensure temporary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space heater vacuum sump pump or other large electrical devices into the UPS The power demands of these devices may overload and damage the unit 6 AC Input Power Cord Heavy duty extra long power cord 7 Output Circuit Breaker Resettable circuit breakers provide output optimal overload protection 8 Input Circuit Breaker Resettable circuit breakers provide input optimal overload protection 9 USB Port The USB port allows connection and communication between the USB port on the computer and the UPS unit 10 Communication Protection Ports Communication protection ports will protect any standard modem fax telephone line network or Ethernet connection RJ11 RJ45 11 Wiring Fault Indicator red This LED indicator will illuminate to warn the user that a wiring problem exists such as bad ground missing ground or reversed wiring If this is illuminated disconnect all electrical equipments
17. r supplies with Power Factor Correction PFC PFC is used to improve the efficiency of power delivery The current US Energy Star Program Requirements for Computers version 5 0 mandates PFC for all power supplies over 100 watts Additionally programs such as 80 Plus are often used to identify high efficiency power supplies with PFC WHAT IS AVR The OR1500PFCRT2U OR2200PFCRT2U OR2200PFCRT2Ua provides complete power protection from utility power that is not always consistent The OR1500PFCRT2U features 1840 Joules of surge protection and the OR2200PFCRT2U OR2200PFCRT2Ua features 2060 Joules of surge protection Both units provide long lasting battery backup during power outages with maintenance free batteries The OR1500PFCRT2U OR2200PFCRT2U OR2200PFCRT2Ua ensures consistent power to your computer system and includes software that will automatically save your open files and shutdown your computer system during a utility power loss AUTOMATIC VOLTAGE REGULATOR The OR1500PFCRT2U OR2200PFCRT2U OR2200PFCRT2Ua stabilizes inconsistent utility power voltage to nominal levels that are safe for equipment Inconsistent incoming utility power may be damaging to important data files and hardware but with Automatic Voltage Regulation AVR damaging voltage levels are corrected to safe levels AVR automatically increases low utility power and decreases high utility power to a consistent and safe 110 120 volts If incoming utility voltage drops below 90 v
18. screen DEFINITION FOR LCD ICONS amp AUDIBLE INDICATION J x NORMAL ER Alarm On Off of Jot Norma Off On Off Beeps twice Utility Failure The UPS is providing power to every 30 seconds battery power supplied outlets from its battery Rapid Beepin Utility Failure The UPS is providing battery P ping power Rapid beeping indicates the unit will every 1 2 second run out of power shortly Battery Overload Occurs when connected equipment exceeds the listed capacity of the Off On On Consan ione UPS Turn the UPS off unplug at least one piece of equipment from battery outlets wait 10 seconds reset the circuit breaker and turn the unit on TROUBLESHOOTING Circuit breaker button is projecting from the side of the unit Turn the UPS off and unplug at least one Circuit breaker has tripped due piece of equipment Wait 10 seconds reset to an overload the circuit breaker by depressing the button and then turn the UPS on Recharge the battery by leaving the UPS Battery not fully charged plugged in Contact CyberPower Systems about Battery is worn out replacement batteries at tech cyberpowersystems com Turn the UPS off Wait 10 seconds and then turn the UPS on The UPS does not perform expected runtime The on off switch is designed to prevent damage from rapidly turning it off and on The unit is not connected to an The unit must be connected to a 110 120V AC outlet 60Hz outlet Contact CyberPower
19. special incidental or consequential damages whether for damage to or loss of property EXCEPT FOR AND ONLY FOR the specific limited agreement of CyberPower to provide certain warranty benefits regarding Connected Equipment under this Warranty loss of profits business interruption or loss of information or data NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you The Product is not for use in high risk activities or with aquariums The Product is not designed or intended for use in hazardous environments requiring fail safe performance or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities or with aquariums CyberPower does not authorize use of any Product in any High Risk Activities or with Aquariums ANY SUCH USE IS IMPROPER AND IS A MISUSE OF THE PRODUCT Where Can Get More Information The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded CyberPower is the warrantor under this Limited Warranty For further information please feel free to contact CyberPower at
20. tal limits of the Product or the equipment connected to it nor for damage while in transit or in storage nor if there has been improper operation or maintenance or use with items not designed or intended for use with the Product such as laser printers appliances aquariums medical or life support devices etc What are the Limitations The sole and exclusive remedies of the Initial Customer are those provided by this Warranty 1 This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code without the use of any adapters or other connectors 2 The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not daisy chained together in serial fashion with any extension cords another Product or device similar to the Product surge suppressor or power tap Any such installation voids the Limited Warranty 3 The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license instruction manual or warnings provided with the Product and the equipment connected to it 4 The Product must have been used at all times within the limitations on the Product s VA capacity The Product was designed to elimin
21. the UPS and the computer These OR units include one serial port and one USB port to allow connection and communication between the UPS and computers The primary computer with PowerPanel Business Edition installed is the computer that you will use to control the UPS and make changes to the operation of the UPS Note only one port USB or Serial can be used at a time When one port is in use the other port will be disabled When there is a power failure the computer connected to the port will start to shut down after a user controlled delay PowerPanel Business Edition will save and close any open files prior to shutting down the system OO 8 FT our RESET e ph Tone worp Yat Sz onesie Serena DPHCE USE UT AG INPUT Me IG FAULT Primary Computer Primary Computer Install PowerPanel Install PowerPanel Business Edition Business Edition BASIC OPERATION DESCRIPTION 1 Power Switch Master on off switch for equipment connected to the UPS 2 Power On Indicator This LED is illuminated when the utility power is normal and the UPS outlets are providing power free of surges and spikes 3 LCD module display Intelligent LCD panel shows all the UPS information using ic
22. tp www cpsww com support or Call us at 877 297 6937 3 If your product requires warranty service you must provide a copy of your dated purchase receipt or invoice How Do You Open A Connected Equipment Claim 1 Call us at 877 297 6937 or write to us at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 or send us an e mail message at claims cpsww com for instructions within 10 days of the occurrence 2 When you contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and Request a Claim Number 3 You must provide a dated purchase receipt or other proof of the original purchase and provide a description of the damage to your connected equipment 4 Pack and ship the product to CyberPower and if requested the item s of Connected Equipment a repair 11 cost estimate for the damage to the Connected Equipment and all claim forms that CyberPower provides to you Show the Claim Number on the shipping label or include it with the product You must prepay all shipping costs you are responsible for packaging and shipment and you must pay the cost of the repair estimate How Long Do I Have To Make A Claim AII claims must be made within ten days of the occurrence What Will We Do To Correct Problems CyberPower will inspect and examin
23. wer RBP435 CyberPower ii 8 hours from total discharge Typical Battery Life 3 to 6 years depending on number of discharge recharge cycles Recommended Battery Sealed Maintenance Free Lead Acid Battery Safety Approvals UL1778 CSA C22 2 No 107 3 FCC DoC Class B SYSTEM FUNCTIONAL BLOCK DIAGRAM Surge Suppressor Input Output Inverter Normal Mode sn gt Battery Mode EEE gt Battery 10 CYBERPOWER GREENPOWER UPS TECHNOLOGY Advanced Energy Saving Patented Bypass Technology CyberPower s patented GreenPower UPS with Bypass Technology reduces UPS energy costs by up to 75 compared to conventional UPS models Even when utility power is normal conventional UPS models constantly pass power through a transformer By contrast under normal conditions the advanced circuitry of a GreenPower UPS bypasses the transformer As a result the power efficiency is significantly increased while ENERGY SAVING decreasing waste heat using less energy and reducing energy costs porns es When an abnormal power condition occurs the GreenPower UPS automatically runs power through its transformer to regulate voltage and provide safe power Since utility power is normal over 88 of the time the GreenPower UPS operates primarily in its efficient bypass mode The GreenPower UPS is also manufactured in accordance with the Restriction on Hazardous Substances ROHS directive making it one of the most