1. Automatic Solid Liquid Extractor Model L 806 USER MANUAL Beacon Innovation International Inc Http www Biii ca Service QBiii ca Page 1 of 8 Http Biii ca BEACON Table of Content A o sce ert waste e O O 2 OperationofFrontPanel L 806 i 2 1 Operation ana setting PT Narr 2 2 AUTO mate el ae Ri COMTO EEE EEEE 2 3 LON 3 Operation Procequre seen A nn A Service Biii ca Page 2 of 8 Http Biii ca BEACON 1 Introduction The L 806 automatic solid liquid extractor adopts the highly efficient Soxlet hot extraction approach It can widely be used in various situations of solid liquid extraction such as food analysis lipid amount determination of drinks textile analysis and analysis of pulp packaging material solvable matter of soil etc Features e The hot extraction method meets AOAC official standard e Full automatic program control without human attention e Manual operation is possible at any step e 6samples 24 hour continuous operation The design of L 806 automatic solid liquid extractor has taken full accounts of various operation requirements and is outstanding for its direct control flexibility and convenience It can store up to 99 editable programs and run according to the selected program Manual intervention operation is allow in any step during a programed run Cooling water Inlet outlet Side view left Side view right Service Biii ca Page 3 o
2. action filled with solvent onto the position on the heating plate Lightly depress the handle adjust the extraction cup position so the cup opening fits well with the sample basket above and then depress the handle fully to lock in Turn on the cooling water valve or circulation pump cooling water flows through the curly cooling tube Edit or select a saved program press the Start Stop key to start the program Once completed press the Start Stop key to turn off the warning whistle While holding the extraction cups with a 6 parallel clamp open the handle lock and lift the handle slightly remove the extraction cups The extraction product in the cups can be examined or sent to further test Install back a clean set of extraction cups depress the handle and lock in Press the rinse valve key to empty the solvent in the solvent chamber Service Bili ca Page 7 of 8 Http Biii ca BEACON 4 Specification Control mode 1 PID control touch key LED display 2 Power lift of sample basket electronic control of rinse valve e Temperature range 20 C 280 C e Temperature accuracy 1 C e Extraction cup volume 90 mL e Overall Power consumption lt 2000W e Power source 220V 50Hz e Net weight 45 kg e External dimension mm L 660 water sprout 40 x W 350 Handle 190 x H 850 Service Biii ca Page 8 of 8 Http Biii ca
3. f 8 Http Biii ca BEACON All parts in the extraction system are made of inert materials They can resist corrosion of various organic solvents ensuring the accuracy and purity of results Sample Basket ESTE Step 2 Step 3 amp 4 Service QBiii ca Page 4 of 8 Http Biii ca BEACON There are four steps in the hot extraction process Step 1 Hot extraction Samples are immersed in the solvent and heated together for extraction Step 2 Rinse Either continuous or intermittent rinse with distilled recycled solvent The rinse time amount of solvent or the time interval of intermittent rinse may be set as desired Step 3 Solvent recycling Solvent is distilled and vapor is condensed collected in the solvent chamber Step 4 Drying The extraction is distilled and dried in the sample cup The system will stop heating and issue warning when drying time is up 2 Operation of Front Panel L 806 2 1 Operation and setting at power on 1 Rinse valve may be turned on at any time by pressing the or key 2 The sample baskets may be rise up or lowered down at any time by pressing the ES or y key 3 The temperature may be set as needed by pressing the key Pressing the PS or h key to desire temperature then press the key again to confirm and set 4 Create or edit a program 1 Select a program number from 01 to 99 2 Press the key to start program the flashing digit may be edited 3 Press the Q or L key
4. t and place the sample into the basket Press the ES key to raise the sample basket Place the extraction cup filled with solvent onto the heating plate at the bottom of the extraction chamber Depress the handle located at the right side of the equipment to seal the extraction cup Turn on cooling water Press the Start Stop Key to start program run Once the program is complete the system issues warning and stops heating Press the Start Stop Key to cancel the warning and resume displaying the program 2 3 Manual Operation 1 2 3 4 5 Service Biii ca Page 6 of 8 Http Biii ca Select program number 00 this is the default program for manual mode The Sample basket ES or y key can be operated as needed The rinse valve or key can be operated as needed The temperature can be set as needed by pressing the key Extraction heating can be turned on or off by pressing the Start Stop Key BEACON 3 Operation Procedure 1 2 3 4 5 6 7 8 9 10 11 12 Load sample to be extracted into a cylinder made of filter paper Place the loaded paper cylinder into the sample basket Turn on the main power switch Press the Sample basket _ or key to lower the basket to the lowest position Place the basket onto the basket sit The basket and the sit are kept together by magnet Press the Sample basket DS key raise the sample basket to the highest position Place the extr
5. to move to next digit press the Jor 4 key to change the value 4 Press the key to save the program 5 Programing demo 1 Press the key the program digit is flashing Select program number 01 2 Press the gt key the Hot Extraction position is flashing Set minute time position as 30 Press the gt key set hour position as 02 The hot extraction time is now set as 2 hours 30 minutes 3 Press the gt key the Cont Rinse position is flashing Set continuous rinse time as 01 30 1 hour 30 minutes 4 Press the i key the Intm Rinse position is flashing Set intermittent rinse time as 02 30 2 hours 30 minutes 5 Press the D key the Wait Btn Rinse position is flashing Set the waiting time between rinse as 00 45 45 minutes 6 Press the gt key the Drying position is flashing Set the drying time as 01 20 1 hour 20 minutes 7 Press the key to save the program 8 Press the key set extraction temperature as 60 C 6 To choose a saved program press the PROGI key and then use the PS or h key to select the program number press the key to confirm selection Service Biii ca Page 5 of 8 Http Biii ca BS EACON 2 2 Automatic program control 1 2 3 4 5 6 7 8 9 Edit or select a program as described in previous section Press the key check or change the temperature setting and confirm the setting Press the h key under sample baske