Home

CLARiTY Laser Controller Connections

image

Contents

1. 2123 e 2123 v Ka OK Language Selection Key Figure 6 16 Default Keypad c The keypad functions the same way as the keypad on a computer Make necessary changes to the information Rev AC AC CLARITY Laser Controller System Manual For date fields do the following tasks d Touch the data window to display the Calendar page see Figure 6 17 A OFFLINE X Job Select Manual Example Change Date 4 2012 Mon Tue Wed Thu Fri Sat Sun Today Default lt a 26 May 2012 Days Offset 0 Months Offset lt 121 22 23 24 25 2 a Years Offset 28 29 30 31 4 0 NN a kl v Cancel Figure 6 17 Calendar Page e Touch the or button to change the month and year f Touch the date on the calendar to choose the date of the month and touch OK Note Any dates that are not available for selection because of pre defined rules that may have been set in CLARISOFT are dimmed Touch OK when you are satisfied that the information in the data window is correct The user interface checks the check box If there are only two user editable fields in the job the user interface automatically displays the second field If there are three or more fields it d
2. Cancel OK Figure 4 14 Select Level Login at level 1 default password 1111 or level 2 default password 2222 password The current password level changes to selected password level from level 0 Where access requires a higher password level the user must first logout and then login at the required password level 4 20 How to Set the Passwords Rev AC CLARITY Laser Controller System Manual Only those functions available at the logged in password level will be visible to the user If there are no options available to the user at that password level a message will be displayed see Figure 4 15 t Access Denied Access Denied You do not have sufficient permissions to access this feature Please tap OK to continue A v OK Figure 4 15 Access Denied Rev AC How to Set the Passwords 4 21 CLARITY Laser Controller System Manual How to clear password Go to home page and touch Logout item 2 Figure 4 16 You will be able to logout from the level currently active item 1 Note Level 1 and Level 2 passwords will automatically logout after a default period of time This feature can be configured in the CLARiTY Configuration Manager Performance Throughput Op m Batch Count 2 Total Count 121 op 14 22 2511 2013 1 Segen Password Level 2 Touch to logout Figure 4 16 Logout Note
3. Enter Product Size Guides the user to measure the product size and input the data Note The first product must reach the product detection light barrier within 5 seconds after confirmation of the product size value Note This option is available only when encoder and or product detector are attached Ea SHUTDOWN X Line Speed Enter Product Size Enter Product Size Measure the product length mmm Press Next to proceed or Cancel to quit A SR Cancel Next gt Table 5 5 Line Speed Page parameters Line Setup 5 17 CLARITY Laser Controller System Manual Parameter Description A SHUTDOWN X aime Speed Enter Product Size lt Enter Product Size 1 Configure the product detector Make sure that leading and trailing edges of your product are detected 2 Measure the product length p L 3 After the Product Size has been entered the system allows 5 seconds to start the conveyor and for the arrival of the leading edge of the product Do you wish to continue and input the Edge Type and Product Size Ho Yes a SHUTDOWN X 9 Product Size Edge Type 4 External Rising v External Falling A lt gt v Cancel OK Measure Line Speed Guides the user to measure the line speed and input the measured value manually Note This option is available only when encoder and or product detecto
4. 5 12 Lane Speed uon exar Eat Seri ovile Mansit I NER a 5 16 Tigger Dex eet eK ees ah ERREUR E 5 19 Morking Field 40 saec eR axo e cr ee eR ake A OS 5 22 Starting the Laser Marking ORO te REA 5 23 Stopping the entip eee ene ea ie oed 5 25 Viewing the Current Job or 5 25 Downloading a Job File van ENEE EI 5 26 Download Job File using TCP IP or Serial Connection 5 26 Download a Job File using USB Memory Stick 5 28 Deleting a Job from the Jobs Database 5 31 Turning Off the Controller aeree Veo orte er ec ved 5 32 Chapter 6 Additional Controller Operations Availability eve ENSE RE E EXE RA RAN ENSE E UN 6 1 T trod OH s ocv EE 6 1 Availability doch coe in 6 5 Availability Fault Table soit E Pra oe Ina roseo boi e rest 6 16 User Editable Fields 5 ona per Re ee RD RR RR CA 6 24 How to Change the Text and Date Fields 6 24 2 Rev AC CLARiTY Laser Controller System Manual Touch To costos ch loce ox eate t el d ote at sa ea E qu diruta 6 28 Production Audit Log Eet S RE Ne 6 30 How to Update Controller 6 32 Updating by USB Key ies ER EE CH CR Cres 6 32 Updating by CLARITY Configuration Manager 6 33 How to Set the Screen Orientation 6 33 Howto Create Job cet eta ee Re ion 6
5. Mains Lead UK 704440 IEC Mains Lead Switzerland 704441 IEC Mains Lead Denmark 704442 Mains Lead Brazil Philippines Table 9 2 Mains Lead IEC Parts List Laser System to Controller Cables Item Part Number Description Quantity Number 1 AL 65970 Network cable 3 Meter 1 RoHS RJ45 to RJ45 Table 9 3 Cables Rev AC Laser System to Controller Cables 9 3 CLARITY Laser Controller System Manual Item Part Number Description Quantity Number 2 AL 74763 Cable Adaptor RJ45 to 1 8 PIN Table 9 3 Cables tem is not shown in the figure Note For information on Illustrated Parts Lists of the laser system refer Laser System Manual 9 4 Laser System to Controller Cables Rev AC Laser Products Limitations Note The CLARITY controller will not support all print functions currently available on the lasers Major unsupported features are as follows 1D Barcode fields Graphic fields Logo fields Preloading of prompt fields with data Custom Fonts Rev AC Limitations 1 Specifications This chapter contains the following topics Technical drawings Technical specifications System specifications Networking and External Communications Terminals Technical Drawings CLARITY Controller 244 mm 92 mm 9 6 E 8 62 inches 170 mm 6 69 inches h LI I E LI EE Figure B
6. Table 5 1 Print Position Page parameters 5 4 Print Position Rev AC CLARITY Laser Controller System Manual Parameter Description Position The Offset X and Offset Y adjustment buttons allows the user to move the position of the marking in either or both of the X or Y axis in both negative and positive direction Position 0 0 indicates the centre of the marking or lens Select one or both buttons to modify the position as required EE X Le Print Position Position Offset X 0 0000mm gt Offset Y 0 0000mm Scale The Scale X and Scale Y buttons allows the user to increase or decrease the scale of the marking in either or both of the X or Y axis Scale 100 is the default value Select one or both buttons to modify the scale as required giPrint Position Scale 100 00 Scale Y 100 0096 Table 5 1 Print Position Page parameters Continued Rev AC Print Position 5 5 CLARITY Laser Controller System Manual Parameter Description Rotation The rotation button allows the user to rotate the job in clockwise or counter clockwise by 360 degrees 0 degree rotation relates to both the line setup and job configuration OFFLINE gt Le Print Position Rotation d 4 0 Min men rn RS Max Default Cancel OK Mark Sets A mark set is a specific set of laser print param
7. 4 v Cancel OK Laser system Allows the user to toggle between laser Operational system and operational availability fault Availability pareto page Table 6 2 Fault Pareto Continued Touch gt to view the Event page see Figure 6 5 Event page displays the date time and duration of each occurrence of that specific fault This page can be used to correlate the occurrence of a fault with other events in the production facility OFFLINE x w Performance Availability Fault Pareto Event 4 E Current Month E09000 Marking head Temperature of FM MHI assembly group too high Duration Date Time mmm ss 10 12 2013 10 31 0 50 gt Figure 6 5 Event Availability 6 9 CLARITY Laser Controller System Manual Touch gt to view the Parameter page see Figure 6 6 Parameter page displays the detailed laser system health parameters logged when the specific fault occurred Gi Fault Pareto Event Parameters Current Month E09000 Marking head Temperature of FM MHI assembly group too high 10 12 2013 10 31 e 1 min 5 min Parameter Event Time batara ERO Global Print Counter 155 155 Line Speed N A N A W Marking Time 26 266ms 26 266ms Encoder Attached Undefined Undefined Y Trigger Detector Attached Undefined Undefined A KE wm Event Log Figure 6 6 Parameter Event Time Itis the time when the fault occurred
8. CLARiTY Laser Controller System Manual Termitals d Palo waked E B 3 Power Supply ius eR End Ex be d e EE da Eae a B 3 Temperature and Humidity B 4 Environment oer ok e EX EE E Re eina B 4 Appendix C CLARITY Configuration Manager rte se coo Yes EE tied utes C 1 CLARiTY Configuration C 2 Glossary 4 Rev AC Introduction The CLARITY Laser Controller is designed to operate the Videojet Laser Coding and Marking systems using the CLARITY operating system The user interface is easy to use and minimizes set up and fault finding time About the Manual This System Manual is written for the every day user of the laser system The System Manual helps the user to understand the different parts and different marking operations of the CLARITY Laser Controller Related Publications Please refer to the system manual s provided with the laser and coding system These documents contain safety setup and operation information for each laser system The following manuals are available for reference CLARiSOFT User Manual Part Number 462458 CLARiSUITE Web server User Manual Part Number 462459 Language Codes When you order this manual make sure to add the 2 digit language code at the end of the part number For example the Danish version of the system manual is part number 462446 18 Table 1 1 on page 1 2 shows the list of language codes that you can use to identify
9. Hide Hide Faults Warnings Status For more information refer to Event Time on page 6 10 Inputs Refer to Inputs on page 4 12 Relative Operating Hours Displays the operating hours since the last service operation was reset Absolute Operating Hours Displays the total number of hours laser system is in operation Laser System State Displays the current Laser system status Table 4 6 Printhead Diagnostics Page Continued Using the Tools Page 4 11 CLARITY Laser Controller System Manual Inputs It displays information about various inputs from the laser see Figure 4 8 A WEST lt Tools Diagno istic cs Printhead Inputs E Laser Clock 2014 04 041 04T13 29 40 0 Trigger Detector Attached undefined Encoder Attached undefined UI 24 Volts Supply 24 1V UI PCB Temperature 27 3 C Figure 4 8 Printhead Inputs Diagnostics Page Buttons Description Laser Clock Displays the current date and time from the laser marking system Trigger Detector Attached Indicates if the trigger detector is present TRUE Encoder Attached Indicates if the encoder is present TRUE UI 24 Volts Supply Displays the instantaneous voltage of the controller 24 V supply UI PCB Temperature Displays the PCB temperature information Table 4 7 Printhead Inputs Diagnostics Page 4 12 Using the Tools Page Rev AC AC CLAR
10. Buttons Description Internal Shows the job stored in the laser system and allows the user to transfer Jobs to the USB memory stick if available The user is also able to delete Jobs from the Internal database Capacity Shows the estimated number of Job files that could be stored on the printer based on the size of existing Job files and the number of bytes of available Job storage remaining External Shows the Jobs stored on the inserted USB memory stick and allows the user to transfer Jobs to the Internal database The user is also able to delete Jobs from the USB memory stick Note Option only available when USB memory stick is inserted in printer Table 4 11 Database Page 4 18 Using the Tools Page Rev AC CLARiTY Laser Controller System Manual How to Set the Passwords The passwords are set and configured through CLARITY configuration manager The UI has the following access levels Level 1 e Level 2 Level 3 E SHUTDOWN X t Tools Select User 9 Level 1 gt Level 2 gt Level 3 gt lt gt v Cancel Figure 4 13 Password Levels Rev AC How to Set the Passwords 4 19 CLARITY Laser Controller System Manual How to Login When a menu requires the user to be logged in above Level 0 the user will be prompted to select the required password level e amp Tools Enter Setup Password
11. Data is shown for 1 minute and 5 minutes prior to the event to illustrate data trends The laser system highlights the parameters which are out of range Combining this information to all noted symptoms can expedite root cause analysis Touch Go to Event Log to view Event log page see Figure 6 7 on page 6 11 You can also view this page by navigating through Tools gt Diagnostics gt Printhead 6 10 Availability Rev AC CLARITY Laser Controller System Manual The Event log retains all activities happening for 180 days period It can be useful to check other laser system activities occurring at the same time as a fault to understand the fault context You can filter to remove status warnings alarms as required e Event Parameters Event Log Event Date Time mmm ss OverallState 10 12 2013 10 31 A E09000 Marking head Temperature of FM MHI assembly 10 12 2013 group too high OverallState 10 12 2013 10 30 OverallState 10 12 2013 10 29 OverallState 10 12 2013 10 29 Y j o PowerOn 10 12 2013 10 29 m y Hide Hide Hide Export to Faults Warnings Status USB Figure 6 7 Event log Symbol Type Alarm event X Warning events Status a laser system event o where no warnings or alarms are wv raised Table 6 3 Event Log symbols Note If an event has caused downtime then the symbol gt will be present
12. along with the Alarm Warning or Status symbols indicating that you can view the laser system parameters at the time of that event Rev AC Availability 6 11 CLARITY Laser Controller System Manual Option Description Hide Alarms Allows the user to Show Hide any alarm events from the event log list Hide Allows the user to Show Hide any warning Warnings events from the event log list Hide Status Allows the user to Show Hide any status events from the event log list Export to Allows the user to export the event log and USB associated parameter snapshots to USB stick The UI will take the user through the steps required to download to USB Table 6 4 Event Log Page Option Touch on the event message for detailed description of the fault or warning event The user interface displays a detailed description likely cause and resolution A OFFLINE X A PECH X Event Parameters Event Log Parameters Event Log FAULT E0900 Duration Marking head Temperature of FM MHI assembly group too Je Event Date Time GEN e high g P y group OverallState 1042 2003 10 31 FAULT E0900 The temperature of the FM or MHI board has exceeded the maximum E 10 12 2013 _ Improve cooling the marking head clean cooling fins if necessary Ensure the air vents are clean Increase distance between markings if possible Check internal fan operation OverallState 10 12 2013 10 30 OverallState 10 1
13. CLARiTYupdate and select the desired software update 6 32 How to Update Controller Software Rev AC CLARITY Laser Controller System Manual Updating by CLARITY Configuration Manager 1 Start the CLARITY Configuration Utility Connect it to the controller Note Ensure that the CLARITY Configuration Utility has a valid connection to the printer This can be observed by the printer icon turning green and the Active Connection message being displayed in the status pane 2 Rightclick on the name of the coder to be updated and select CLARiTYupdate option 3 Locate the file with the same name as the part number above CLARITY update starts automatically 4 Oncompletion navigate to Tools gt Diagnostics gt Control gt Versions and ensure that all of the software versions match with those listed below Note Use of a serial link for the CLARITY update is not recommended due to the size of update and the resulting transmission time How to Set the Screen Orientation Depending on the position in which the CLARiTY controller is mounted it may be necessary to rotate the screen image by 180 degrees To change the screen orientation proceed as follows 1 Navigate to Tools gt Setup gt Control Control page appears see Figure 6 23 amp OFFLINE e Tools Setup Control lt on CLARITY Parameter Archives gt Set Screen Orientation 0 Degrees gt Internationalisation Recalibrate T
14. Clear this fault and resume operation E6203 Requested font not available on the laser Requested font 1 is not available on the laser marking head copy of the font 1 should be downloaded to the laser and the job re selected When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6204 Unsupported Field Parameter Inverse Field 1 has the Inverse parameter set This is not supported for inclusion within an XML Template When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6205 Unsupported Field Parameter Mirror Field 1 has the Mirror parameter set This is not supported for inclusion within an XML Template When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6206 Unsupported Field Parameter Transmitted Field Field 961 has the Transmitted Field parameter set This is not supported for inclusion within an XML Template When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6207 Invalid Counter Field Counter field 1 cannot be read from the Ciff file Review the field for unsupported laser content in Clarisoft and reload the job When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messa
15. Line Setup A SHUTDOWN X 9 gj Tools Setup Printhead Line Setup 4 Position And Orientation A Line Speed gt Trigger Settings gt Marking Field gt Figure 5 8 Line Setup Buttons Description Position and Orientation Allows the user to adjust the position and orientation of the laser head with respect to the product Table 5 3 Line Setup Buttons Line Setup 5 11 CLARITY Laser Controller System Manual Buttons Description production line is set to Static Line Speed Allows the user to adjust the speed of the Note This option is disabled if the line movement settings Start Delay Blocking Delay Trigger Mode page 5 19 Trigger Settings Allows the user to adjust the following print trigger For more information refer Trigger Settings on Field on page 5 22 Marking Field Defines the marking field size Allows to switch between full marking field and user defined marking field For more information refer Marking Table 5 3 Line Setup Buttons Continued Position and Orientation 5 12 Line Setup a SHUTDOWN 9 Line Setup Position And Orientation Line Movement Product Side Selection Laser Position Manual Laser Position Job Orientation Manual Job Orientation Y Current Settings lt gt v 270 gt 180 Figure 5 9 Position and Orientation Rev A
16. The following machine events are logged e CLARITY Started software version PCB serial number e CLARITY Exit Power Failure detected Fault Warning raised Fault Name Fault Warning cleared Fault Name Parameters download CCFG The following user events are logged Each user event is also labelled with name of the user performing the change when advanced passwords are turned on Parameter change Param Name old and new value CLARITY Clone restored File name CLARITY Archive restored File name CLARITY Update started update name Rev AC Production Audit Log 6 31 CLARITY Laser Controller System Manual Touch on any event log to view the details of the log see Figure 6 22 Production Audit Log Parameter change E Parameter change Occured 11 52 59 12 03 2013 Details Parameter Imaging Preview QuickPosition Field00 XPosition Parameter Type 1 Old Value 13 New Value 200 A S OK Figure 6 22 Parameter Change How to Update Controller Software You can update the controller software by following methods USB key e CLARITY Configuration Manager Updating by USB Key 1 Copy the CAB file into the clarityupdate folder on the root of a USB drive 2 Plug the USB drive into the coder 3 Follow the on screen instructions Note If the instructions does not appear automatically after 15 seconds navigate to Tools gt Setup gt Control gt
17. The laser system must be turned on to download job files 2 Click the laser system icon from the tool bar in CLARiSOFT The Print window appears see Figure 5 14 on page 5 26 3 Ensure that the Real Time Coder is selected 4 Ensure that the correct laser system is displayed in the Select Output Device menu 5 Select Download under Image Options Printer Type JWindows Printer Select Output Device Videojet CLARITY Laser 3020 Enter Number of Prints Required 0 Unlimited Image Options Download Print What Current image Figure 5 14 Select Output Device 5 26 Downloading a Job File Rev AC AC CLARITY Laser Controller System Manual 6 To download only the currently opened Job file select the Current Image button To download multiple Job files that have been saved to the PC select the File button and navigate to the location on the PC where the files are saved Highlight all of the Jobs you wish to transfer and select Open A preview or list of the selected job s appears see Figure 5 15 lob Selection Confirmation pm Piesze corte that the folowing mages cortan the corect data CLARSOFT Samay CLARICOM _ Figure 5 15 Print Preview of Job Click the OK button The Progress window which displays the status bar appears The status bar indicates the status of the job downloading process see Figure 5 16
18. 1 CLARITY Controller Dimensions Rev AC Technical Drawings 1 CLARITY Laser Controller System Manual Technical Specifications Table B 1 lists the technical specifications of the CLARITY controller Technical Speci fication Length Width Screen L in mm Height Controller User 92 interface CLARITY 8 4 TFT SVGA Table B 1 Technical Specifications System Specifications Table B 2 lists the system specifications System Specifica tions Operator Interface Description Full color LCD touch panel CLARITY Interface Job selection and database support as stan dard WYSIWYG mark preview Operator Interface Lan guages Operator Interface is available in the languages listed in Table 1 1 on page 1 2 Password protection Three user levels System Configuration CLARITY configuration manager Software Offline set up and parameter storage available as standard Diagnostics On board diagnostics as standard On board Memory SD Card Table B 2 System Specifications B 2 Technical Specifications CLARITY Laser Controller System Manual Networking and External Communications Table B 3 lists the networking and external communication systems and its components Networking and Exter Component nal Communications External Data Commu RS232 point to point communications nication Ethernet 10 100 base TX network communica tions
19. 2b 98 d0 c9 csv and PS 74 de 2b 98 d0 c9 csv OK Figure 6 13 Export Success f Select OK and remove the USB stick Availability 6 15 CLARITY Laser Controller System Manual 3 The files can be exported into Microsoft EXCEL or other spreadsheet tools and can be used to create graphs and logs for use in monitoring the laser performance see Figure 6 14 Event Id Date Time Event Type Event Duration minutes 136 10 12 2013 10 52 00 INFO OverallState 106 10 12 2013 10 34 37 INFO OverallState 105 10 12 2013 10 34 37 INFO OverallState 104 10 12 2013 10 34 04 FAULT E10813 No encoder connected 0 18 103 10 12 2013 10 31 25 INFO OverallState 102 10 12 2013 10 31 24 FAULT E09000 Marking head Temperature of FM MHI assembly group too high 0 83 101 10 12 2013 10 30 01 INFO OverallState 100 10 12 2013 10 29 56 INFO OverallState 99 10 12 2013 10 29 51 INFO OverallState 98 10 12 2013 10 29 38 INFO PowerOn Figure 6 14 Exported Data in Microsoft EXCEL Availability Fault Table This table lists the faults that affect laser and operational downtime For detail information on Error and how to clear the error refer Table 8 4 on page 8 6 Description of Fault Laser System Down Operational Downtime time faults impacting faults impacting the the laser availability operational availability E00100 Critical error SP Yes Yes E00101 Stack error SP Yes Yes 00102 SP rec
20. 9 TCP IP Parameters Using the Tools Page 4 15 CLARITY Laser Controller System Manual Laser Information 4 16 Using the Tools Page It provides information about the laser system used along with the software versions A Sonne X AOS FPGA ASP FM lt gt QMark Diagnostics Contro Laser Information Om Printer Model 3120 Serial Number Laser Name Ser 13254000180 Laser 3120 8 3 1 Figure 4 11 Laser Information Buttons Description Printer Model Displays the model of the laser system Serial Number Displays the serial number of the laser system Laser Name Displays the laser system name AOS Displays the version of AOS FPGA Displays the version of FPGA ASP Displays the version of ASP Table 4 10 Laser Information Rev AC AC CLARITY Laser Controller System Manual Buttons Description FM When selected displays the following screen OFFLINE x Control Laser Information FM o PN 0 FM Index Sw 0 0 0 0 0 QMark Displays the version of QMark Table 4 10 Laser Information Continued Using the Tools Page 4 17 CLARITY Laser Controller System Manual Working with Database Navigate to Tools gt Databases see Figure 4 12 Tools Databases E Internal Capacity o ey 5 di X External nd 4 12 Database Page
21. Binary and ASCII Comms Protocols and Win dows and Drivers Host PC mode Remote database using CLARINET USB Port Network Control Soft CLARICOM CLARINET laser system inde ware pendent network management software Table B 3 Networking and External Communications Terminals Power Supply Table B 4 lists the power supply performance values Power Supply 90 264 V 100 240 VAC 50 60 Hz Requirements 24V 25W Table B 4 Power Supply Performance Rev AC Networking and External Communications 3 CLARITY Laser Controller System Manual Temperature and Humidity Attributes Temperature Range 5 45 Rate of change Maximum 10 per ambient temperature hour Humidity 10 to 90 Relative non condensing Table B 5 Temperature Environment The laser controller is provided with IP 40 rating B 4 Terminals Rev AC CLARITY Configuration Manager Introduction CLARITY Configuration Manager lists all the configurable parameters of the printer Rev AC Introduction C 1 CLARITY Configuration Manager Menu Options Value Min Unit Availability AvailabilityScreen ProxyType value 1 0 1 Pareto Collection Sort By 0 Sort By 1 Downtime 1 Sort By Fre quency EventLog Progress Value 0 0 100 Result Value 0 0 3 Status Value 0 0 3 Devices PHds 1 Co
22. Check if the surface is As Required Clean the surface by wiping with a dry soft clean cloth or cotton pad Table 7 2 Laser System Maintenance Schedule Note Refer to laser manuals for information on maintenance of lasers For information on maintenance of the laser system refer to Laser System Manual Rev AC Maintaining the Controller 7 3 Troubleshooting This chapter contains the following topics Fault messages and warnings Controller fault Marking faults Additional faults e CLARITY error messages and warnings Diagnostics Fault Messages and Warnings If the user interface displays a fault or warning perform the following Read the fault or warning message Perform the task as per the message Clear the message from the display sometimes the message clears automatically when the fault is corrected and sometimes you have to clear it by touching the Clear button Rev AC Fault Messages and Warnings 8 1 CLARITY Laser Controller System Manual Reading a Fault Message or Warning When a fault or warning occurs CLARITY displays the fault message in the status window at the top of all pages When a fault occurs the laser system s fault output relay will open If this relay is wired into the packaging machine s stop circuit it can be used to ensure that the packaging machine is stopped in the event of an error This prevents the uncoded product from being produced when the laser system has a fa
23. Enable CLARITY Config Archive Not Archived 100 LastUpdated 05 30 2012 100 10 02 37 WebServer Enabled 0 No 1 Select yes to enable Web Server 1 Yes Table C 1 CLARITY Configuration Manager Continued 9 Glossary Availability The amount of time that an equipment is ready to run when required for production Job or Image Job is the set of characters that is required to be marked on the product label Label Job or Image Scanner Head Model After the laser beam is expanded by the telescope it reaches the marking head Two movable mirrors deflect the laser beam such that it passes over the lines of the opened template on the product The lines are divided into vectors X and Y coordinates that is horizontal and vertical LCD LCD is a thin flat display device made up of any number of color or monochrome pixels arrayed in front of a light source or reflector Line Select Line Select mode allows the controller to hold multiple jobs in RAM which in turn allows the user to select the jobs for marking Line selection mode allows up to 16 jobs to be configured on the laser system BCD mode Line Select Refresh the Print Memory The print memory is updated automatically within CLARITY Repeat Mark When Repeat marking is enabled the laser system will continue to mark even if the product is queued Repeat mark Multi mark mode Rev AC Glossary 1
24. Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10007 QMark update failed Please try the update again Please try to update QMark again using the web interface If that fails a second time contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10008 A change requires rebooting the laser Please reboot the laser to apply your changes This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10101 Version conflict command not executed An unknown command has been sent to the ACC via the Ethernet interface If the Ethernet communication has been disturbed separate the connection and then connect again When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10102 Unknown command An unknown command has been sent to the ACC via the Ethernet interface Check program which is sending the command When the fault is corrected a Clear button will appear b
25. No Yes E10007 QMark update failed Please Yes Yes try the update again E10008 A change requires rebooting Yes Yes the laser E10101 Version conflict command Yes Yes not executed E10102 Unknown command Yes Yes Table 6 5 Fault Table Continued 6 18 Availability Fault Table Rev AC Description of Fault CLARITY Laser Controller System Manual Laser System Down time faults impacting the laser availability Operational Downtime faults impacting the operational availability E10103 Key not found in system Yes Yes database E10104 Database write error Yes Yes E10105 Database read error Yes Yes E10106 Template contains no data No Yes E10107 Template does not exist No Yes E10108 No variables in template No Yes E10109 Format is invalid No Yes E10111 Errors while saving Yes Yes E10113 This database entry cannot No Yes be deleted since other entries depend on it E10114 The transmitted object cannot No Yes be saved to the database Please check whether your System supports the object E10115 Too many variables are used No Yes in the templates Please delete all templates you do not need E10116 Error while reading directory Yes Yes E10300 Data for initialization cannot Yes Yes be read completely from the database E10302 Shutter does not stay open Yes Yes E10303 Shutter does not stay closed Yes Yes E10401 Template invalid Yes Yes
26. OH 1 2 3 Max med 4 5 6 Default of 7 8 9 5 M Cancel OK Table 5 4 Position and Orientation Page Parameters Continued 5 14 Line Setup Rev AC CLARITY Laser Controller System Manual Parameter Description Job Orientation Allows the user to select the orientation of the marking with respect to the product a SHUTDOWN X 9 0 Position And Orientation Job Orientation 4 ABC H T ow pu o 2 gt Cancel OK Manual Job Allows the user to enter the angle precisely from 0 to 359 degrees Orientation a SHUTDOWN X wj Manual Job Orientation 4 180 Oje EMEN E 359 4 5 6 Default of 71 8 9 0 a gt S Cancel OK Current Settings Screen shows the graphic representation of the current line setup SHUTDOWN 9 Line Setup Position And Orientation 4 A v quM OK X Table 5 4 Position and Orientation Page Parameters Continued Rev AC Line Setup 5 15 CLARiTY Laser Controller System Manual Line Speed This option sets the rate at which the product passes the marking head see Figure 5 10 Note This option is disabled when the line movement is set to Static Note A wizard is available to take the user through the steps required to set up line speed when an encoder and or a product detector are fitted Note If there is no en
27. Output Device menu Note If you do not select the correct output device the image will not be correct for the laser system 5 Select Print to File from Image Options Select the USB memory device to use from the drop down menu Note The Print What options will not display until a suitable memory device is selected To download only the currently opened Job file select the Current Image button To download multiple Job files that have been saved to the PC select the File button and navigate to the location on the PC where the files are saved Highlight all of the Jobs you wish to transfer and select Open Downloading a Job File 5 29 CLARITY Laser Controller System Manual 8 Theconfirmation window appears see Figure 5 19 Job Selection Confirmation Please confirm that the following images contain the correct data CLARISOFT Summary Cx CLARICOM Figure 5 19 Confirmation Window 9 Click the OK button to continue After the files are downloaded the message shown in Figure 5 20 appears Progress Completed m X CLARICOM beage Coote Huragereent Sows Figure 5 20 Download Complete N Caution Failure to use the Print to File procedure will result in errors and rotated images 10 Remove the USB Memory stick from the PC 5 30 Downloading a Job File Rev AC CLARITY Laser Controller System Manual Deleting a Job fr
28. Overtemperature gt 60 When the fault is corrected a Clear button will appear below Clear this fault and resume operation E00205 Internal cooling circuit Flow too low Problems within the cooling circuit of the system Faulty coolant flow switch Check coolant level and pump operation Check coolant flow switch and cable Check fuseboard operation ACC interface and cables to ACC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00206 RF circuit VSWR fault Mis match between RF PSU and laser tube Faulty RF cable or laser tube Faulty RF PSU Check RF cable Check RF PSU operation Check laser tube operation Check ACC interface board operation and cables This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00207 RF circuit Overmodulation System software error RF PSU faulty Faulty cables between ACC ACC interface board and RF PSU Check modulation output to RF PSU Check cable between ACC and RF PSU Check RF PSU operation Check ACC interface board operation Check ACC operation This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system A
29. Power ONT time Power Off time in fault state Where Power ON time is the time for which the laser system is switched ON irrespective of the status of the laser Operation Downtime is the amount of Production Time the laser system has spent in an Operation Fault State Operational Fault state is defined as the period where the laser system is not available due to a fault identified as a operational fault Operation Downtime Total time in a fault state Operation Downtime When the laser system enters a laser system fault state as indicated in Table 6 5 on page 6 16 the downtime counter starts The laser system remains in this operation fault state until the fault is cleared The operation to clear the fault is indicated in the Table 6 5 on page 6 16 If the laser system is powered down in a operation fault state the downtime counter continues until laser system is powered on and the fault is cleared Rev AC CLARITY Laser Controller System Manual Availability Page Touch Performance on the Home page Logout Level 2 17 21 31 10 2013 E ES TEST 2 original JOB e al Performance Q Throughput Op m Batch Count 2 o Total Count 7238571 Figure 6 1 Home page Displays the Performance Page Touch Availability to access the availability page as Performance e Batch Count 3 Total Cou
30. Rising Select the trigger mode as External Rising if the trigger pulse is to be given by the product that is entering the product detection zone External Falling Select the trigger mode as External Falling if the trigger pulse is to be given by the product that is leaving the product detection zone Internal Once If Internal once is selected then marking is started on selecting the start button Internal Continuous If Internal Continuous is selected then marking is continuous and can be stopped manually Note The default value is External Rising Note If the line direction is static then all the four modes are available else only External Rising and External Falling modes are available e SHUTDOWN X 9 Line Setup Settings Trigger Mode 4 External Rising External Falling nternal Once v Internal Continuous Cancel OK Table 5 6 Trigger Settings Page parameters Continued Rev AC Line Setup 5 21 CLARITY Laser Controller System Manual Marking Field There may be obstacles on the line that obscure part of the laser marking area The actual marking area of the laser is restricted to inhibit the laser in these areas If the maximum marking field is not being used Use Max Marking Field is set to No then the user can select each border to the required size This option allows the user to increase or decrease any or all of the four borders of the laser marking area see Figure 5
31. The trigger settings page allows the user to set the following parameters Parameter Description Start Delay Start Delay defines the distance until the marking process is started which is the distance between the center of the marking field of the laser system and the center of the marking on the product After the trigger the product has to cover this distance before is in front of the marking head If No Product Movement is selected then the start delay defines the time between start trigger pulse and marking in milliseconds ms a SHUTDOWN X 9 8 Line Setup Trigger Settings Start Delay 4 0 000ms gt Min 0 000ms 1 2 3 Max 16000 000ms 4 5 6 Default 0 000ms y 8 9 0 gt Cancel OK Blocking Blocking defines the distance the product has to cover before the next marking can be started If No Product Movement is selected then the blocking defines the time that the product has to pass after a start trigger until a next trigger is accepted a SHUTDOWN X 9 Trigger Settings Blocking Delay 4 10000 000ms gt Min 0 000ms 1 2 3 Max 16000 000ms 4 5 6 Default 0 000ms 7 8 9 ES 0 i v Cancel OK Table 5 6 Trigger Settings Page parameters 5 20 Line Setup Rev AC CLARITY Laser Controller System Manual Parameter Description Trigger Mode Allows the user to select one of the following settings to determine the trigger for the product marking External
32. VIDEOJET CLARITY Laser Controller System Manual P N 462446 01 Revision AC J une 2014 Copyright June 2014 Videojet Technologies Inc herein referred to as Videojet All rights reserved This document is the property of Videojet Technologies Inc and contains confidential and proprietary information owned by Videojet Any unauthorized copying use or disclosure of it without the prior written permission of Videojet is strictly prohibited CLARITY is a registered trademark Videojet Technologies Inc 1500 Mittel Boulevard Phone 1 800 843 3610 Offices USA Atlanta Chicago Wood Dale IL Fax 1 800 582 1343 Int l Canada France Germany Ireland 60191 1073 USA Int l Fax 630 616 3629 Japan Spain Singapore Netherlands www videojet com and The United Kingdom Distributors Worldwide Compliance Information Rev AC For Customers in the U S A Safety The equipment complies to UL 60950 1 NRTL accredited certification Emissions The equipment complies with USA Part 15 of the FCC Rules subpart B Class A Operation of the equipment is subject to the following two conditions 1 This equipment may not cause harmful interference and 2 This equipment must accept any interference received including interference that may cause undesired operation A Warning PERSONAL INJURY Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to
33. are connected directly to the controller 3 2 The Complete Laser System Rev AC CLARITY Laser Controller System Manual The controller is supplied with a standard mounting bracket 1 Touch UI 4 Laser Ethernet 7 Main Power Switch 2 Ethernet 2 Connection 8 USB 3 Ethernet 1 5 Mains Lead Connector 9 Serial Port IOIOI 6 Fuse Holder Figure 3 1 Controller Connections Ports Description Ethernet 1 Allows the user to communicate with corporate LAN or local PC through RJ45 Ethernet Cable Ethernet 2 Allows the user to communicate with corporate LAN or local PC through RJ45 Ethernet Cable Laser Ethernet Allows the user to communicate with laser Connection system through standard RJ45 Ethernet Cable Mains Lead Connection to the mains power Connector Fuse Holder Threaded holder for the AC Mains Power fuse Main Power Turns the system ON OFF Switch Table 3 1 Controller Connections Rev AC CLARITY Laser Controller Connections 3 3 CLARITY Laser Controller System Manual Ports Description USB USB Port that allows the connection of a USB memory stick for functions such as laser system software updates transferring Jobs and backup restore of laser system archive or clone files Serial Port RS 232 Serial Port for connecting to PC IOIOI PLC or other capable device special adapter cable required Table 3 1 Controller Connections Interconnecting Cable Mains
34. by the customer The power supply of the customer interface is not available or switched off Check if power is supplied between terminals X16 1 and X16 5 of customer interface on ACC board For units equipped with CAN IO connect bus terminal KL9110 pin 2 or pin 6 to external 24 V and pin3 or pin7 to external GND When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10905 The CAN bus detected a not implemented event Depending on the event a function to be implemented in the future has been used e g CI terminal reserved Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10906 The customer interface Cl indicates an error of the external exhaust External exhaust defective or incorrect wiring of CI terminal Repair external exhaust or connect the corresponding Cl terminal to 24 V This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10907 The customer interface Cl indicates an external error Detection of external error or incorrect wiring of the Cl terminal Remove external error or connect the corresponding Cl terminal to 24 V This fault cannot be cleared dire
35. database and save all data This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 25 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E10005 Cannot read backup of the system database The backup has not been generated at the previous start of the system or it has been deleted Check memory space of the MMC MultiMediaCard This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10006 Overflow of system database By changing or adding an entry to the system database the admissible size has been exceeded Shorten entries of variable length and retry changes The following settings can have an impact SmartGraph Configuration dialog System Settings name in the field Identification YAG systems Number of digits after the decimal point for the ageing factor SmartGraph Configuration dialog Marking head Number of digits after the decimal point in the fields Mounting position Working distance Marking head and Pilot laser This fault cannot be cleared directly Turn off the
36. directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10508 Error while reading the laser file The laser file does not exist in the comp directory of the MMC MultiMediaCard The MMC is not inserted correctly Check MMC if necessary reinstall software on MMC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10509 Error while reading the head file The head file does not exist in the comp directory of the MMC MultiMediaCard The MMC is not inserted correctly Check MMC if necessary reinstall software on MMC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings 8 30 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E10510 No FPGA image file available The file fpgaimgX h is missing on the MMC MultiMediaCard Check the contents of the MMC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system Afte
37. edit the user field proceed as follows 1 When ajob is selected the list of user editable fields in the job are displayed 6 24 User Editable Fields Rev AC CLARITY Laser Controller System Manual 2 Touchthe required field from the list to select it the first one in the list is automatically selected The default data for that field appears in the preview window Figure 6 15 Job Select Variable Data four e FieldOO 1 Best Before gt Field01 Q9 26 Apr 2012 gt Cancel Edit SA Figure 6 15 Default Data Window Best Before 26 04 2012 3 Ifthe information in the preview window is the information that you want to print go to step 5 If you want to change the information perform step 4 4 Touch Edit to modify the information For text fields do the following tasks a Use the alpha key pad to enter the data The CLARITY Operating system supports a number of standard languages for use with User Entered text information Rev AC User Editable Fields 6 25 CLARITY Laser Controller System Manual 6 26 User Editable Fields b Touch the Language Selection Key to access the available language selections see Figure 6 16 OFFENE Xx Job Select Variable Data four FieldOO 1 Best Before 5 n
38. format Then the warning message will no longer be displayed After conversion the database cannot be read by an older AOS When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10504 Not all previously used templates have been saved New templates have been added to the database and selected for marking Then the system has been booted without saving the changed database Save the database after creating or importing new templates When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10505 The template used last was not saved A new template has been added to the database and selected for marking Then the system has been booted without saving the changed database Save the database after creating or importing new templates When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10506 Invalid value of absolute operating hours in SRAM The battery backing up the SRAM is running down Check battery and replace if necessary When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10507 Error while reading the objective file The objective file does not exist in the comp directory of the MMC MultiMediaCard The MMC is not inserted correctly Check MMC if necessary reinstall softvare on MMC This fault cannot be cleared
39. gt v Change Printer Operational Sort By Timeframe Availability Figure 6 4 Fault Pareto for Operational Availability Option Description Fault type Description of the error code and fault Touch the fault type to view the detailed description of the fault and possible solutions Downtime The total duration of time the laser system was in this fault state Table 6 2 Fault Pareto Availability 6 7 CLARITY Laser Controller System Manual 6 8 Availability Description Frequency The number of times the laser system had this fault in the time frame gj Performance Availability Fault Pareto Sort By 4 Sort By Downtime Q V Sort By Frequency A lt gt T v Cancel OK Sort By Allows the user to sort the list based on laser system downtime or fault frequency c Fault Pareto Select TimeFrame v Last 30 days Last 90 days Current Month gt KE July 2012 June 2012 Cancel OK Change Allows the user to view fault pareto page for Timeframe different available time frames Table 6 2 Fault Pareto Continued Rev AC AC CLARITY Laser Controller System Manual Option Description o Ju Availability Fault Pareto Select Type 4 Printer Availability Operational Availability Power On time Operational Availability Running time
40. interval turn on the Laser Controller and the laser marking system and confirm normal operation E10555 The AllprintBasic command Warning has been executed Depending on the AllprintBasic program When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10601 No template list selected The external template selection has failed because no template list has been selected Create and select a template list using Smart Graph When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10602 The chosen template number cannot be assigned to any template The external template selection has failed because the selected template number cannot be assigned to any template in the template list Check template list When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10701 Out of memory Cannot create database object Internal error or database is too large If the message is no longer displayed after rebooting there might be an internal error Inform the technical support group If the message is still displayed after rebooting all elements not needed should be deleted from the database When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10702 Format error while creating a database object Version conflict between dat
41. is corrected a Clear button will appear below Clear this fault and resume operation E00103 Timing error SP Fatal internal error Internal timing was not met Contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings 8 18 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E00104 AOS data transfer delayed During marking the AOS transfer of data has been delayed The marking operation is aborted Change the mark set parameters so that the marking is carried out slower When the fault is corrected a Clear button will appear below Clear this fault and resume operation E00105 Marking aborted product movement too fast The marking has been aborted because less than 50 vectors were marked before the product left the marking field Usually this is caused by the marking process being to slow It is also possible that the start distance is too small and the marking is started too late The start distance should always be long enough so that no part of the marking is in the marking field at the time the laser is triggered Enlarge the start dista
42. memory Reselect the job using the menu from the Home screen The job The orientation setting has been Check the Job Orientation settings and orientation is incorrectly set correct incorrect The mark Laser Position setting is Check the Laser Position setting and position is incorrect correct incorrect Table 8 2 Marking Faults 8 4 Controller Fault Rev AC CLARITY Laser Controller System Manual Note For information on laser system faults refer Laser System Manual Additional Faults Fault The job cannot be opened Cause The job is not compatible with this Firmware version Solution The job must be newly created for this Firmware version After a certain number of marks the user interface automatically A counter field is marked in which the counter end value is predefined and the user interface switches to OFFLINE Change the specifications for the job requested a line that is not configured switches to mode when this value is OFFLINE reached A limited mark run has been Change the specifications for the job specified in the job settings Invalid Line The line selection inputs have 1 Use CLARITY Configuration Manager to check that the correct number of lines have been setup for this system 2 Check if the line selection inputs are connected properly 3 Touch the Clear button to clear this warning message No Line Selected A mark signa
43. on the Control dialog box Communications dialog box appears gt E Diagnostics Control Communications 4 E lt TCP IP Displays the configuration and status of the laser system s network port For more information see TCP IP on page 4 15 Production Audit Log Refer to Production Audit Log on page 6 30 Image Update Queue Displays all Jobs currently in the laser system s queue and the number of times each Job has been allocated to print No Print Limit indicates that the currently loaded Job will continue to print until a new Job is loaded Laser Information Refer to Laser Information on page 4 16 Table 4 8 Control Diagnostics Page Continued 4 14 Using the Tools Page Rev AC AC TCP IP CLARITY Laser Controller System Manual OENE X Control Communi IP Address Laser IP Address Subnet Mask CLARITY Communications Text Communications cations TCP IP Figure 4 10 TCP IP Parameters Buttons Description IP Address Displays the IP Address of the controller Laser IP Address Displays the IP Address of the Laser system Subnet Mask Displays the Subnet Mask number CLARITY Communications Displays the TCP IP port number and CLARITY network status Text Communications Displays the TCP IP port number assigned for Text Communications Table 4
44. than two CI input bus terminals connected Not enough input bus terminals existing Equip system with two input bus terminals This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10922 Less than two CI output bus terminals connected Not enough output bus terminals existing Equip system with two output bus terminals This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10923 Ext template selection requires at least 4 Cl input bus terminals To use the external template selection at least 4 input bus terminals must be available at the customer interface Add two input bus terminals This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10926 Entry is missing in the database Defective database Complete or exchange database When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10929 CAN bus error Faulty line of CAN bus Check CAN bus cable and connections When the fault is corrected a Clear button
45. the Clear button below to clear this fault message E1219 Invalid Job File Invalid Barcode Size The Job file is invalid and needs to be corrected using Clarisoft A Data Matrix Barcode field in the Job file has invalid dimensions Press the Clear button below to clear this fault message E1220 Invalid Job File Invalid Barcode ECC Type The Job file is invalid and needs to be corrected using Clarisoft A Data Matrix Barcode field in the Job file has an unsupported ECC type Only ECC 200 is currently supported Press the Clear button below to clear this fault message Table 8 4 Error Messages and Warnings 8 10 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E1221 Invalid Job File Barcode uses unsupported coding The Job file is invalid and needs to be corrected using Clarisoft A Data Matrix Barcode field in the Job file uses a form of data compression not currently supported by CLARITY Press the Clear button below to clear this fault message E1222 Invalid Job File Barcode encoding failed The Job file is invalid and needs to be corrected using Clarisoft A Data Matrix Barcode field in the Job file failed to encode into a valid image Press the Clear button below to clear this fault message E1223 Invalid Job File Invalid Date Reference The Job file contains a dat
46. will appear below Clear this fault and resume operation E10930 Connected customer interface is ignored due to a database entry A customer interface is connected to the system However in the system database CI CAN it has been defined that no customer interface is to be used If the system does not require a customer interface it should be removed If it is required the entry Cl CAN IO of the database has to be set to 1 When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19201 Template does not exist The template does not exist in the database Create or transmit the corresponding template When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 37 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E19202 Faulty template The template selected for marking is defective or does not exist Check template and used parameters product registration and if existing logos Select template again When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19203 Parameter set does not exist The parameter mark set required by a template is missing Assign an existing mark set to the template or add the required parameter set to the databas
47. 1 CLARiTY Laser Controller System Manual Note Operational Availability can be changed between two separate production time proxies as required by the user power on and running mode For more information refer Operational Availability on page 6 3 Operating Time Availability Planned Production Time Where Operating Time is Total Laser system Uptime e Planned Production Time is the Actual Line Run Time Expected D Based on proxy selected power on or running Laser System Availability Laser System Availability tracks the downtime directly related to an internal error fault such as Power supply Overtemperature Fault Beam Shutter Fault Filter Full Fault Laser System Availability is defined as Laser System Downtime Laser System Availability 1 Laser System Total Time Laser System Total Time is the total amount of time for which the laser system is turned on has power applied If the laser system is powered down when a fault is active the amount of time that the laser system is off is also included in this laser system total time Laser System Total Time Power On time Power Off time in fault state 6 2 Availability Rev AC AC CLARiTY Laser Controller System Manual Laser System Downtime is the amount of Laser System Total Time the laser system has spent in a Laser System Fault State Laser System Fault State is defined as the period where the La
48. 12 e SHUTDOWN E 9 gj gt Printhead Line Setup Marking Field 4 Use Max Marking Field No ud 30 0000mm 25 0000mm ge t H 25 0000mm gt 30 0000mm A v Cancel OK Figure 5 12 Marking Field The border limits are determined by the edge of the marking area nearest to the border being moved and the current position of the opposite border For example the left border is limited by the left edge of the marking area and the current right border 5 22 Line Setup Rev AC CLARITY Laser Controller System Manual If Use Max Marking Field is set to Yes the controller uses the maximum set marking field for marking see Figure 5 13 Use Max Marking Field elt SHUTDOWN Printhead Line Setup Marking Field 33 7966mm 44 0212mm 44 0212mm 33 7966mm Yes A S v Cancel Figure 5 13 Marking Field Max Starting the Laser Marking 1 Ifthe laser system has a manual keyswitch turn to close position keyswitch button If the laser system has a software keyswitch press the on the home screen Enter the password if prompted Note There will be no password prompt if passwords are disabled or if the user has already logged in When keyswitch status is enabled closed the status bar indicates STARTING UP and changes to OFFLINE The stop and start run icons becom
49. 2 2013 10 29 This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking PowerOn 10 12 2013 10 29 system and confirm normal operation OveraliState 10 12 2013 10 29 DH v Hide Hide Hide Export to Faults Wamings Status USB Figure 6 8 Event log diagnostics This data can be exported to USB for further interrogation See Export to USB on page 6 13 section for information on how to export to USB stick 6 12 Availability Rev AC AC CLARITY Laser Controller System Manual Export to USB The following information can be exported to an external USB stick in a csv format Availability Metrics Event Log Do the following tasks to export the data to the USB stick 1 Insert USB stick to the external USB connector Note Export To USB button is activated only when a USB stick is inserted Note Ensure that the USB stick does not have any previous exported data as you will be asked to overwrite the files see Figure 6 9 vent Parameters Event Log Overwrite 4 Existing Event Log files EL 00 0f 41 00 e8 cd csv and PS 00 0f 41 00 E e8 cd csv have been found on this USB device Do you wish to overwrite A lt gt i Cancel Overwrite Figure 6 9 Overwrite Files 2 Export to USB Availability 6 13 CLARITY Laser Controller Syste
50. 34 CLARITY Power Savini Ses zelo not pet goo 6 35 Chapter 7 Maintenance Replacement Instructions EE e ERO RAS e EA 7 1 Information on Care ee Be Gut ee pw sce 7 2 Maintaining the Power Supply 7 2 Replacing the Mains 7 2 Maintaining tbe ge opt Re 7 3 Chapter 8 Troubleshooting Fault Messages and Warnings 8 1 Reading a Fault Message or 8 2 Clearing a Fault Message or Warning suussssursuuu 8 3 Controller Fault siot eoo rh tate ke ie Epid bi uos dE 8 4 Marking Faults eset idee ea Vc A CREDERE Ok EA 8 4 Additional i ere epe eee e aed 8 5 CLARITY Error Messages Warnings n u assssan suana 8 6 Ke 8 43 Chapter 9 Illustrated Parts List Standard Controller Assembly caue ee dE SUR 9 1 Laser System to Controller 9 3 Appendix A Laser Products Tamitatons o vebuueel b oe eS ee bee LG A 1 Appendix B Specifications Technical ete Vb ce pev Ae NER ee edt B 1 CLARITY Controller cess hit hot ot oe PE MU ko er ts B 1 Technical 5 B 2 System Specifications s oie ees Ee REX REY EK ERE E EK E 2 Networking and External Communications B 3 Rev AC 3
51. 3610 Fax 1 800 582 1343 International Fax 630 616 3629 Web www videojet com Service Program About Total Source Commitment Total Source TOTAL SERVICE PLUS RELIABILITY is the Videojet Technologies Inc commitment to provide you our customer the complete service you deserve The Total Source Commitment The Videojet Total Source Service Program is an integral part of our business in providing marks codes and images where when and how often customers specify for packages products or printed materials Our commitment includes Applications support nstallation services Maintenance training Customer response center Technical support Field service Extended hours phone assistance Parts and supplies Repair service iii CLARiTY Laser Controller System Manual Customer Training If you wish to perform your own service and maintenance on the laser system Videojet Technologies Inc highly recommends you complete a Customer Training Course on the laser system Note The manuals are intended to be supplements to and not replacements for Videojet Technologies Inc Customer Training For more information on Videojet Technologies Inc Customer Training Courses call 1 800 843 3610 within the United States only Outside the U S customer should contact a Videojet subsidiary office or their local Videojet distributor for more information iy Rev AC Table of Contents Compliance Informati
52. 38111 v 22444 Figure 4 7 Printhead Diagnostics Page Buttons Description Scanner Type Displays the type of scanner installed on the laser Product Counter Displays the total product count for this batch i e the number of products passing the laser coder Print Counter Displays the total number of products that have been marked by the laser marking system for this batch Global Print Counter Displays the total number of products marked Marking Time Displays the time the laser beam is ON for one mark Line Speed Displays the speed of production line Note This option will only be displayed if there is product movement Table 4 6 Printhead Diagnostics Page 4 10 Using the Tools Page Rev AC AC CLARITY Laser Controller System Manual Buttons Description Event Log Contains the log of events faults and warnings over a total period of 180 days Allows the user to select a fault or warning event on the screen for further information Also allows the user to hide various events such as faults or warnings and export the information to USB as required amp OFFLINE X D EventeParameters Event Log E Event Date Time Dato mmmss E OveraliState 10 12 2013 1031 10 12 2013 1 o OveraliState 10 12 2013 10 30 OveraliState 10 12 2013 10 29 OveraliState 10 12 2013 10 29 PowerOn 10 2 2003 10 29 Hide
53. 8 Parts of the marking are not within the marking field of the marking head Parts of the marking are outside the ellipse representing the maximum marking field of the marking head Reduce size of marking Select lens with higher focal length Reposition template fields and make sure all items are within the marking field When the fault is corrected a Clear button will appear below Clear this fault and resume operation E09012 Communication error ACC FM MHI Gaps in the data flow Faulty communication between ACC and FM MHI Check connection between ACC and marking head optical fibre or LVDS connection When the fault is corrected a Clear button will appear below Clear this fault and resume operation E09016 Communication error ACC gt FM MHI inadmissible command ACC sent a command to the marking head which is not admitted in the current mode Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E09017 Communication error ACC gt FM MHI unknown command ACC sent an unknown command to the marking head Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E09018 Communication error ACC gt
54. Basic Syntax error No Yes E10551 The template does not No Yes contain the requested variable E10553 Illegal command in No Yes AllprintBasic command string Table 6 5 Fault Table Continued 6 20 Availability Fault Table Rev AC Description of Fault CLARITY Laser Controller System Manual Laser System Down time faults impacting the laser availability Operational Downtime faults impacting the LOTO ERE ZELLE 0 E10554 The AllprintBasic command No Yes Error has been executed E10601 No template list selected No Yes E10602 The chosen template number No Yes cannot be assigned to any template E10701 Out of memory Cannot Yes Yes create database object E10702 Format error while creating a Yes Yes database object E10800 DSP does not send Yes Yes telegrams E10811 DSP buffer overflow Yes Yes E10813 No encoder connected No Yes E10814 No trigger detector connected No Yes E10900 General CAN bus error No Yes E10901 A CAN node has carried out Yes Yes an inadmissible reset E10902 Lost connection to a CAN Yes Yes node E10903 A CAN node cannot be Yes Yes initialized E10906 The customer interface Cl No Yes indicates an error of the external exhaust E10907 The customer interface Cl No Yes indicates an external error E10909 A CAN node has carried out Yes Yes an inadmissible state change E10913 File is missing
55. C CLARITY Laser Controller System Manual The position and orientation page allows the user to set the following parameters Parameter Description Line Movement Allows the user to set the direction of Job relative to the laser head Select line movement where product moves from left to right pus or from right to left 4m or is Static mb no line movement SHUTDOWN Position And Orientation Line Movement 4m L 2 m mp du A lt gt Cancel X 4 Product Side Selection Sets the side of the product that needs to be marked The red color indicates the side on which the marking happens a SHUTDOWN X 9 Product Side Selection 4 WI py a lt gt Cancel OK Note The last two selections are only available if Line Movement is set to the Static option Table 5 4 Position and Orientation Page Parameters Rev AC Line Setup 5 13 CLARITY Laser Controller System Manual Parameter Description Laser Position Allows the user to select the graphic from the four orientations available SHUTDOWN X 9 gj Position And Orientation Laser Position d L cl d S Cancel OK Manual Laser Allows the user to enter the angle precisely from 0 to 359 degrees Position ES SHUTDOWN X wj Manual Laser Position K 4 270 gt Min
56. Controller System Manual Error No Report on CLARITY Operator Interface E55001 Defective customer interface Cl Incompatible bus terminal The bus terminal used is not supported Beckhoff error Check the bus terminals of the customer interface When the fault is corrected a Clear button will appear below Clear this fault and resume operation E55002 Defective customer interface Cl EEPROM error An error occurred while saving the configuration to the EEPROM Beckhoff error Check the bus terminals of the customer interface When the fault is corrected a Clear button will appear below Clear this fault and resume operation E55003 Defective customer interface CI Connection error between bus terminals There has been a communication error between the Beckhoff terminals Terminal ERROR Beckhoff error Check the bus terminals of the customer interface When the fault is corrected a Clear button will appear below Clear this fault and resume operation E55004 Customer interface Cl Unknown error The bus coupler of the customer interface Cl has sent an undocumented error Check the bus terminals of the customer interface When the fault is corrected a Clear button will appear below Clear this fault and resume operation E58100 Customer interface Cl CAN bus warning limit exceeded The bus coupler of the customer interface received too many error frames successively Chec
57. E10404 External text Value can be No Yes marked only once E10407 The beam shutter does not Yes Yes open E10408 The beam shutter does not Yes Yes close E10409 System error during Yes Yes preparation of marking Table 6 5 Fault Table Continued Rev AC Availability Fault Table 6 19 CLARITY Laser Controller System Manual Description of Fault Laser System Down time faults impacting the laser availability Operational Downtime faults impacting the operational availability E10500 Cannot load database Yes Yes E10501 Backup database has been Yes Yes loaded E10507 Error while reading the Yes Yes objective file E10508 Error while reading the laser Yes Yes file E10509 Error while reading the head Yes Yes file E10510 No FPGA image file Yes Yes available E10511 No SP program available Yes Yes E10512 AllprintBasic Protocol No Yes configuration error E10513 AllprintBasic Configuration No Yes error of the serial interface E10514 FM MHI download error Yes Yes E10515 FM MHI download File is Yes Yes missing E10516 The marking head is not Yes Yes connected E10518 The parameter set does not No Yes correspond to the laser type Please replace this entry in the database E10519 Please select a lens Yes Yes corresponding to the marking head E10520 A marking head has been No Yes identified which is not admitted for this laser type E10550 Allprint
58. E10551 The template does not contain the requested variable The variable to be modified in the AllprintBasic command string does not exist in the template Check the corresponding template or the AllprintBasic command string and modify if necessary If the command string has been changed the ACC must be rebooted This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10552 AllprintBasic MsgBox This is a regular message no error The AllprintBasic command string triggered the output of this message When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10553 Illegal command in AllprintBasic command string This AllprintBasic version does not support the command Check command string and change if necessary If the string has been changed you have to reboot the ACC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10554 The AllprintBasic command Error has been executed Depending on the AllprintBasic program Depending on the AllprintBasic program This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short
59. Emgreencies ec pese eame xx At TRE ee pM 2 5 Chapter 3 Installation Unpack and Inspect the Laser System and the Controller 3 1 The Complete Laser EE 3 2 CLARITY Laser Controller Connections 3 2 Interconnecting Cable 2 EIERE RE ERE ER ER 3 4 How to Connect the Laser Marking System to the CLARITY Laser ENEE s De e pae ek ee preda wb dei 3 5 Rev AC CLARiTY Laser Controller System Manual How to Setup the System vt ae one eter wi ace wei e DRE eg 3 5 Prerequisites 5 e I 50 0 0 ube pee be EE 3 5 Startup EIER gros winnie erectos n eade ore teh ere Cede ete net 3 6 Chapter 4 CLARITY Operating System Inttoduetonss EE AE 4 1 Usine the Home EE 4 2 Using the TOOLS srs ove oL eda eet coa ocu e et 4 4 Working with Setup Page 4 5 Working with Diagnostics 0 cee eee eee eee 4 9 Working with Database i ces cree eee ae RR 4 18 How to Set the 4 19 imis EO ecol EE E 4 20 How to clear 4 22 Chapter 5 Controller Operation Starting the Controller s esi vb e EE EES EE apa t 5 2 Selecting a Job for Marking 0 5 3 Print Postion seest eie nTa tex ha ted trop Peu fme qe etm efte 5 4 hui do Cr 5 7 INDE Setup oe pe eo boten adel ghee ed ET RE d A bs a urs 5 11 Position and Orientation
60. FM MHI Protocol error ACC did not keep to protocol Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E09021 Internal error Cannot set control mode of the FM MHI The FM MHI cannot change to control mode This indicates an error in the communication between ACC and FM MHI Check connection between ACC and marking head This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E09022 Internal error Cannot set configuration mode of the FM MHI The FM MHI cannot change to configuration mode This indicates an error in the communication between ACC and FM MHI Check connection between ACC and marking head or MHI This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 23 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E09023 Internal error Cannot set download mode of the FM MHI The FM MHI cannot change to download mode This indi
61. File PDF417 Barcode out of Specification The Job file is invalid and needs to be corrected using Clarisoft A PDF417 or Micro PDF417 barcode field in the Job file contains more columns than the barcode symbology supports Use Clarisoft to check and correct the PDF417 and Micro PDF417 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1233 Invalid Job File PDF417 Barcode out of Specification The Job file is invalid and needs to be corrected using Clarisoft A PDF417 or Micro PDF417 barcode field in the Job file contains more rows than the barcode symbology supports Use Clarisoft to check and correct the PDF417 and Micro PDF417 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1234 Invalid Job File PDF417 Barcode out of Specification The Job file is invalid and needs to be corrected using Clarisoft A PDF417 or Micro PDF417 barcode field in the Job file contains more characters than can be encoded with the specified column and maximum row sizes Use Clarisoft to increase the number of columns or rows in the PDF417 and Micro PDF417 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1235 Invalid Job File EAN13 Price Too Large The Job file is invalid and needs to be cor
62. For information on Performance refer to Availability Page on page 6 5 Note For information on Print Position refer to Print Position on page 5 4 4 22 How to Set the Passwords Rev AC Controller Operation This chapter contains the following topics Rev AC Starting the Controller Selecting a Job for Marking Print Position Line Setup Starting the Laser Marking Stopping the Marking Viewing the Current Job or Image Downloading a job file Deleting a job from the jobs database Turning Off the Controller 5 1 CLARITY Laser Controller System Manual Starting the Controller Note Before starting the controller please ensure that the laser system is started as described in the Laser System Manual 1 Turn the controller mains power switch ON The CLARITY startup screen appears see Figure 5 1 Figure 5 1 CLARITY Startup Screen 2 Once the laser system is ON and communication is established and if the keyswitch is disabled status bar changes to SHUTDOWN see Figure 5 2 amp SHUTDOWN X 10 56 04 11 2013 0 Throughput Opim gt Batch Count 15 gt Total Count 104 Figure 5 2 Laser System ON 5 2 Starting the Controller Rev AC CLARITY Laser Controller System Manual Selecting a Job for Marking JOB 3 Touch the Job button on the home page Note Jobs are created in CLARISOFT Jobs can be downlo
63. ITY Laser Controller System Manual Working with Control Diagnostics Navigate to Tools gt Diagnostics gt Control see Figure 4 9 Versions System Information Communications Production Audit Log Image Update Queue Laser Information 4 Figure 4 9 Control Parameters Buttons Description Versions Displays the software versions of the various software components installed in the CLARITY controller Note If there is any inconsistency among the software components that are installed in the CLARITY controller the Software Part Number displays the message Incompatible Software Versions If this is seen a CLARITY software update must be performed OFFUNE x Tools Diagnostics Control Versions Software Part Number 404756 r01 2014 02 26 CLARITY 4 03 00 14646 35540 CLARITY Boot Loader 1 00 00 0015 Operating System Version 6 00 00 0015 Operating System Build Date 2014 01 06 15 49 38 Q System Information Displays the serial number and revision number of controller Printed Circuit Board PCB CPU speed and system equipment reference information Table 4 8 Control Diagnostics Page Using the Tools Page 4 13 CLARITY Laser Controller System Manual Buttons Description Communications Touch Communications
64. Manual Error No Report on CLARITY Operator Interface E10517 According to the system database there is no marking head connected The system database contains the entry MARKING_HEAD_ATTACHED 0 Thus the marking head is not addressed If you want to mark a marking head must be connected and the entry in the system database has to be changed to MARKING HEAD ATTACHED 1 Please contact the technical support group When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10518 The parameter set does not correspond to the laser type Please replace this entry in the database A database has been copied to the MMC which does not correspond to the laser type Copy a suitable database to the MMC or create a new suitable database using the Smart Graph offline Add a parameter set having the same name and transfer it to the laser In this way all parameter sets of the laser database need to be replaced This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10519 Please select a lens corresponding to the marking head A lens and laser head mismatch has been detected Please select the appropriate lens installed for this system If you receive this error and the head lens configuration has not changed it may indicate an FM b
65. No Yes E10914 Faulty transmission to a node No Yes E10915 A CAN node does not react Yes Yes after download or software reset E10916 Faulty download to node Yes Yes Table 6 5 Fault Table Continued Rev AC Availability Fault Table 6 21 CLARITY Laser Controller System Manual Description of Fault Laser System Down time faults impacting the laser availability Operational Downtime faults impacting the operational availability template sequence must be identical E10917 A CAN node signals unsuit Yes Yes able software E10918 A problem with the RF driver Yes Yes file occurred E10919 A driver error prevents Yes Yes triggers being transmitted from the CAN bus E10920 A driver error prevents control Yes Yes of the red emission LED E10921 Less than two Cl input bus Yes Yes terminals connected E10922 Less than two Cl output bus Yes Yes terminals connected E10923 Ext template selection No Yes requires at least 4 Cl input bus terminals E10926 Entry is missing in the Yes Yes database E10929 CAN bus error Yes Yes E19201 Template does not exist No Yes E19202 Faulty template Yes Yes E19203 Parameter set does not exist Yes Yes E19204 Product registration does not Yes Yes exist E19205 At least one index level does Yes Yes not exist in the parameter set E19210 The direct marking cannot be No Yes carried out E19301 The te
66. Progress x4 Completed Q i 9 eo CLARICOM Detai Figure 5 16 Progress Window Ensure the Job now exists in the laser system s database see Selecting a Job for Marking on page 5 3 Downloading a Job File 5 27 CLARITY Laser Controller System Manual 8 Disconnect the communications cable between the PC and the laser system if no longer needed Download a Job File using USB Memory Stick Do the following tasks to download a job file from the PC to the laser system using a USB memory stick 1 Insert the USB memory stick into the PC 2 Onthe File menu click Job Download see Figure 5 17 The Download window appears see Figure 5 18 on page 5 29 CLARISOFT C Users Administrator Desktop 4head_elipse ciff si Edit View Tools Help zt gt T Lane Ctrl N X Gm a zy Open Ctrl O e we Ctrl Save As Ctrl Ll Date Calculations Data Sources ee Select Coder MN ENT Properties Print Preview Print tt Hig Job Download Recent Files Exit 5 28 Downloading a Job File Rev AC Rev CLARITY Laser Controller System Manual Dowrnioad WA Documents Tech Pubs Laser POD font not fend ot X Figure 5 18 Job Download Command Ensure that the Real Time Coder is selected see Figure 5 18 Ensure that the correct laser system is displayed in the Select
67. SOFT to ensure that all jobs contain the same configuration for this global counter Press the Clear button below to clear this warning message E1239 CLARITY Data File Complete All data has been printed in the current CLARITY Data File Please select a new Job to resume printing Note you will have to install a new CLARITY Data file before selecting the Job if that job uses a CLARITY Data file Press the Clear button below to clear this fault message E1240 Missing CLARITY Data File There is no CLARITY Data File installed in this printer and the selected Job uses a CLARITY Data file to lookup the data it prints Please select a new Job or install a CLARITY Data file to resume printing Press the Clear button below to clear this fault message E1241 CLARITY Data File Failed There is a problem with the installed CLARITY Data file Please select a new Job or install a new CLARITY Data file to resume printing Press the Clear button below to clear this fault message E1242 Invalid Job File Barcode data too long The Job file is invalid and needs to be corrected using Clarisoft A QR Barcode field in the job file contains too many data characters for the selected dimensions Press the Clear button below to clear this fault message E1243 Invalid Job File Avoidance Date The Job file contains a calculated date that is an avoidance date Use Clarisoft to check and correct the calculat
68. Table C 1 CLARITY Configuration Manager Continued C 3 Rev AC CLARITY Laser Controller System Manual Menu Options Value Min Max Unit Comments PulsesPer 40 1 1000000 Revolution Position HeadRotation 0 3 Orientation r 2 3 JobOrienta 180 0 359 degree tionManual LaserPosi 270 0 359 degree tionManual LineMove 0 2 ment 1 2 ProductSide 0 5 Selection1 2 3 4 5 ProductSide 0 3 Selection2 i 2 3 Trigger Blocking 10000 0 16000000 ms Settings TriggerDelay BlockingTrig 10000 0 16000000 mm gerDistance StartTrigger 0 0 16000000 ms Delay StartTrigger 88662 0 16000000 mm Distance Table C 1 CLARITY Configuration Manager Continued Rev AC C 4 CLARITY Laser Controller System Manual Menu Options Value Min Max Unit Comments TriggerMode 0 External 3 Rising 1 External Falling 2 Internal Once 3 Internal Continuous CLARITY Data File Character Set 0 ASCII 2 1 UTF8 2 Unicode DateCodes Day Of Month lt 1 gt lt 2 gt lt 3 gt 2048 Set up required date and time Codes lt 4 gt lt 5 gt codes Day of Week lt A gt lt B gt lt C gt 512 Codes lt D gt lt E gt Hour Codes lt A gt lt B gt lt C gt 1024 lt D gt lt E gt Minute Code
69. V Check voltage supply at the marking head at the power supply module in the control unit and at the marking head connector This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 21 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E09002 Marking head Overpositioning of X mirror Due to an error the X mirror was brought to a position beyond the admitted maximum area Check X mirror Check wiring in the marking head Ensure your message is inside the marking window When the fault is corrected a Clear button will appear below Clear this fault and resume operation E09003 Marking head Overpositioning of Y mirror Due to an error the Y mirror was brought to a position beyond the admitted maximum area Check Y mirror Check wiring in the marking head Ensure your message is inside the marking window When the fault is corrected Clear button will appear below Clear this fault and resume operation E09004 Marking head Overcurrent X mirror The current consumption of the X mirror is too high Check X mirror Check wiring in the marking head Can be caused by overpositioning Reduce jump speed mark
70. abase object and AOS Check versions of Smart Graph and QMark and carry out an update if necessary When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 33 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E10800 DSP does not send telegrams The DSP has not been initialized correctly or the connection to the DSP is faulty Restart the system If the error persists contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10811 DSP buffer overflow Internal communication error This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Contact your local service representative or support team who will be able to provide assistance E10812 Invalid SmartSP telegram Internal communication error Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will a
71. aded from PC to the controller or using USB memory stick Refer Downloading a Job File on page 5 26 Note Refer to the CIFF Converter Instruction P N 468427 01 to convert Laser XML messages to CIFF jobs 4 Thelist of existing jobs are displayed see Figure 5 3 ES SHUTDOWN X 9 Job Select 30 CHARACTER TEST 2 riginal Cancel OK Figure 5 3 Job List 5 Select the required job from the list The job print preview appears 6 Touch OK the controller selects the job ready for marking Note If the job download fails warnings will be flagged on the unit Review the warnings and if necessary correct the job in CLARiSOFT and download again Rev AC Selecting a Job for Marking 5 3 CLARITY Laser Controller System Manual Print Position Touch Print Position button o at the left hand bottom side of any screen to adjust the current job parameters m e a Print Position 4 Laser Source gt Position gt Scale gt Rotation o Mark Set Figure 5 4 Print Position Screen The print position page allows the user to set the following parameters Parameter Description Laser Beam Source The user can select the beam source as pilot laser or marking laser The pilot laser if available when selected will show the path of the job without marking when job started Selecting marking laser will allow the laser to mark
72. an and printing visibly clear barcodes If possible verify the printed barcodes with a separate barcode verifier Check the scanner mounting and for obstruction preventing the scanner seeing the barcodes If the problem persists call your local service representative Once resolved and ready press the Clear button below E1602 BarcodeFault The barcode scanner has read a different barcode than the one printed onto the label The barcode scanner may not be mounted correctly Call your maintenance engineer or local service representative Press the Detail button below for maintenance assistance When ready press the Clear button below The barcode scanner has read a different barcode to the one printed on the label This could be due to the scanner seeing another barcode in its field of view check the mounting and configuration of the scanner This could also be due to a print error or a communications error with the scanner or a hardware fault with the scanner Power off and check cabling between labeller and scanner then re try If the problem persists call your local service representative Once resolved and ready press the Clear button below E1603 Miss read reported The Barcode Scanner has reported a Miss Read Consider recalibrating the scanner Press the Clear button below to clear this fault message Table 8 4 Error Messages and Warnings 8 14 CLARITY Error Messages a
73. ar this fault and resume operation E19303 The heads of templates of a template sequence must be identical Template sequences are not supported yet When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19304 The product registrations of templates of a template sequence must be identical Template sequences are not supported yet When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19305 Product registration does not exist Template sequences are not supported yet When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19306 Defective template in the template sequence Template sequences are not supported yet When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings 8 38 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E19307 The circuit for external laser enable has been opened The circuit for the external laser enable is open This can be caused by an open emergency switch Close the circuit for external laser enable When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19308 Cannot select beam source Error i
74. ar this fault message E1505 Logging Job Events Disabled Logging of Job events has been disabled This is because Job selections and Job updates are happening too frequently The printer can only log Job events once every 10 seconds Logging of Job events can be re enabled via the IncludeJobEvents parameter in CLARITY Configuration manager if the frequency of Job events is reduced Press the Clear button below to clear this warning message E1601 Barcode Fault The barcode scanner cannot read the barcodes printed onto the labels Check printhead is clean and printing clear barcodes onto the labels Check that labels are applying properly to the packs and that they are not wrinkled Check that the barcode scanner is not obstructed from scanning the barcodes If the problem persists call your maintenance engineer or local service representative Press the Detail button below for maintenance assistance When ready press the Clear button below The barcode scanner has reported multiple consecutive no reads which exceeds the pre set limit This can be caused by very poor print quality or poor label application resulting in barcodes which cannot be scanned It can also be caused by physical obstruction of the scanner or a hardware fault in the printhead or scanner Check that labels are being applied correctly to the pack Check that the applied label is not wrinkled on the pack Check that the printhead is cle
75. ark Set will be presented as a list of buttons see Figure 5 6 on page 5 8 Note If the laser key switch is closed then the buttons will be read only c RUNNING x Mark Set Default On Marking Speed 500 mm s gt O Mark Delay 20 us gt Stroke Delay 120 us gt Jump Speed 1000 mm s gt Jump Delay 200 us gt Mark Intensity 50 gt A Laser On Delay 20 ps gt lt gt Laser Off Delay 120us gt Figure 5 6 Mark Sets Parameters Buttons Description Marking Speed Allows the user to enter the marking speed in millimeter per second mm s It is the speed of movement of the laser beam when marking the product This value ranges from 1 to 30000 Mark Delay Allows the user to enter the mark delay in microseconds us It is the delay between the marking of individual vectors within a stroke This value ranges from 0 to 999 Stroke Delay Allows the user to enter the stroke delay in microseconds us It is the delay between the end of a stroke and the jump to the next stroke This value ranges from 0 to 2000 Table 5 2 Mark Sets parameters 5 8 Print Position Rev AC AC CLARITY Laser Controller System Manual Buttons Description Jump Speed Allows the user to enter the jump speed in millimeter per second mm s It is the speed of movement of the laser beam when moving from one stroke to the next The laser is switched off during a
76. atabase Check template and save it When the fault is corrected Clear button will appear below Clear this fault and resume operation E10108 No variables in template The variables requested via Ethernet do not exist in the template Check template When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10109 Format is invalid Via Ethernet a command with missing or incorrectly formatted parameters has been sent Correct the format of the command When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10111 Errors while saving The MMC MultiMediaCard is full not inserted correctly or defective Check MMC When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10113 This database entry cannot be deleted since other entries depend on it Other database entries depend on this entry Delete the depending entries first E10114 The transmitted object cannot be saved to the database Please check whether your system supports the object Version conflict Check versions and make an update if necessary When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10115 Too many variables are used in the templates Please delete all templates you do not need Number of variables or number of templates to
77. ate the checksum were not valid Use Clarisoft to check and correct fields using checksums in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1215 Invalid Job File invalid barcode height The Job file is invalid and needs to be corrected using Clarisoft The height supplied for a barcode in the Job file is smaller than the minimum allowed by the barcode specification Use Clarisoft to check and correct the barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1216 Invalid Job File Barcode Symbology Not Installed The Job file contains a barcode symbology that is not installed in this printer Use Clarisoft to remove the barcode from the Job file Then download the corrected file to the printer Press the Clear button below to clear this fault message E1217 Invalid Job File Undefined Format Identifier The Job file is invalid and needs to be corrected using Clarisoft A Data Matrix Barcode field in the Job file uses a Public Format ID which is not currently defined Press the Clear button below to clear this fault message E1218 Invalid Job File Data too long The Job file is invalid and needs to be corrected using Clarisoft A Data Matrix Barcode field in the Job file contains too many data characters for the selected dimensions Press
78. b file is invalid and needs to be corrected using Clarisoft EAN128 barcode fields with an application identifier of 23 should contain a length digit following the application identifier Use Clarisoft to check and correct the EAN128 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1206 Invalid Job File EAN barcode out of specification The Job file is invalid and needs to be corrected using Clarisoft An EAN128 barcode field in the Job file does not have the number of characters that are specified by its application identifier Use Clarisoft to check and correct the EAN128 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1207 Invalid Job File EAN barcode out of specification The Job file is invalid and needs to be corrected using Clarisoft An EAN128 barcode field in the Job file contains variable length data followed by a separator character separator characters should not be used to terminate data in an EAN128 barcode Use Clarisoft to check and correct the EAN128 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1208 Invalid Job File EAN barcode out of specification The Job file is invalid and needs to be corrected using Clarisoft An EAN128 barcode field
79. cates an error in the communication between ACC and FM MHI Check connection between ACC and marking head or MHI This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E09100 No communication with marking head No marking head connected Faulty power supply of marking head Faulty connection between ACC and FM MHI Faulty FM MHI Check power supply of marking head Check connection between ACC and marking head or MHI When the fault is corrected Clear button will appear below Clear this fault and resume operation E09101 Internal error Error status of the FM MHI cannot be reset The error flags on the FM MHI cannot be reset This indicates an error in the communication between ACC and FM MHI Check connection between ACC and marking head or MHI This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E09102 Interrupted communication with marking head There have been errors on the ACC while receiving data from the FM MHI Faulty connection between ACC and FM MHI Faulty FM MHI Check connection between ACC and marking head or MHI This fault cannot be cleared directly Turn off the Laser C
80. ce of data but that field is missing from the job file Use Clarisoft to ensure that all data source fields used in the Job file are present and correct in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1102 Invalid Job File duplicate named fields The Job file is invalid and needs to be corrected using Clarisoft Duplicate field names were found in the Job file Use Clarisoft to remove or rename fields so that there are no duplicates Then download the corrected file Press the Clear button below to clear this fault message E1103 Invalid Job File invalid graphic The Job file is invalid and needs to be corrected using Clarisoft The Job file refers to a missing or invalid graphic bitmap file Use Clarisoft to check and ensure that all bitmap files used by this Job file display properly in Clarisoft Then download the corrected file Press the Clear button below to clear this fault message Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 7 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E1104 Invalid Job File invalid date field The Job file is invalid and needs to be corrected using Clarisoft The Job file you are trying to select contains an incorrectly specified Date Calculation The Default Offset for the date falls outside of the date range sp
81. coder connected to the laser then the following options will be available Enter or Measure Fixed Speed Configure Manually Note Before running any wizard ensure that the line is stopped and follow the instructions in the wizard a SHUTDOWN X Setup Printhead Line Setup Line Speed 4 Enter Fixed Speed Measure Line Distance A A Enter Product Size gt Measure Line Speed gt gt Configure Manually lt gt Figure 5 10 Line Speed 5 16 Line Setup Rev AC AC CLARITY Laser Controller System Manual The line speed page allows the user to set the following parameters Parameter Description Enter or Measure Fixed Allows the user to input the line speed either by Speed entering it directly or measuring the speed Measure Line Distance Allows the user to record the line distance moved while the laser system counts encoder pulses Note This option is available only when encoder and or product detector are attached Pei SHUTDOWN X Line Speed Measure Line Distance 4 Measure Line Distance 1 Make reference marks on the conveyor belt and a stationary fixture that are next to each other p 2 Jog or move the line manually Ensure that the encoder rotates at least one full rotation 3 Measure the distance moved and enter the value on the next screen 2 o 4 Press Next to proceed or Cancel to quit Cancel Next gt
82. ctly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 35 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E10908 External STOP from the Cl The STOP input is supplied constantly with 0 V so that the START input is not evaluated Connect STOP input to 24 V When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10909 A CAN node has carried out an inadmissible state change The CAN node has probably carried out a reset Check wiring of CAN bus Check CAN node This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10913 File is missing The file is supposed to be on the MMC MultiMediaCard Copy desired file to the MMC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10914 Faulty transmission to a node Erroneous wiring of CAN bus Check wiring of CAN bus This fault cannot be cleared directly Tur
83. current Y Yes Yes mirror E09006 Marking head No X mirror Yes Yes connected E09007 Marking head No Y mirror Yes Yes connected E09012 Communication error ACC gt Yes Yes FM MHI Gaps in the data flow E09021 Internal error Cannot set Yes Yes control mode of the FM MHI Table 6 5 Fault Table Continued Rev AC Availability Fault Table 6 17 CLARITY Laser Controller System Manual Description of Fault Laser System Down time faults impacting the laser availability Operational Downtime faults impacting the operational availability E09022 Internal error Cannot set Yes Yes configuration mode of the FM MHI E09023 Internal error Cannot set Yes Yes download mode of the FM MHI E09100 No communication with mark Yes Yes ing head E09101 Internal error Error status of Yes Yes the FM MHI cannot be reset E09102 Interrupted communication Yes Yes with marking head E09103 Internal error FM MHI not in Yes Yes configuration mode cannot executed command E09104 No data received from the Yes Yes marking head E10001 No data can be read from the Yes Yes system database E10002 Backup of system database Yes Yes was loaded E10003 Cannot write all to the No Yes backup of the system data base E10004 Cannot write to system data Yes Yes base E10005 Cannot read backup of the Yes Yes system database E10006 Overflow of system database
84. ding routines and diagnostic functions Databases page Provides control over the jobs database of the laser system Table 4 3 Tools Page Working with Setup Page Navigate to Tools gt Setup see Figure 4 3 A OFFLINE Xx Tools Setup Printhead e Control lt Consumables Options Figure 4 3 Setup Page The Setup page allows you to access the following parameters Printhead Consumables Control for example time date language Options Note Consumables and Options are not available for Laser controller Using the Tools Page 4 5 CLARITY Laser Controller System Manual Working with the Printhead Setup Page Navigate to Tools gt Setup gt Printhead see Figure 4 4 DG OFFLINE X Lens Type go Pilot Laser lt _ gt Tools Setup Printhead Om Line Setup gt Focal Distance Working Distance CO2 F95 D36 gt 95 00mm 96 50mm gt Figure 4 4 Printhead Setting Buttons Description Line Setup For information on Line Setup Wizard refer Line Setup on page 5 11 Lens Type Shows a list of available lens types for the connected laser system when selected Select the required lens from the list Focal Distance Displays the focal distance of the selected lens Working Distance Displays the working distance for the selected lens that is the distance at which t
85. e Check wiring of the CAN bus When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings 8 42 CLARITY Error Messages and Warnings Rev AC Error No CLARITY Laser Controller System Manual Report on CLARITY Operator Interface E58106 Customer interface Cl Guarding of CAN bus delayed or failed The CAN bus has not been connected correctly to the bus coupler of the customer interface Check wiring of the CAN bus When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings Note For training support on advanced applications call Videojet Technologies Inc at 1 800 843 3610 for all customers within the United States Outside the U S customers should contact their Videojet Technologies Inc distributor or subsidiary for assistance Diagnostics The diagnostic screens show the current value of different parameters which help you in troubleshooting the laser system To access the diagnostics screen Navigate to Tools gt Diagnostics Figure 8 4 For more information refer Working with Diagnostics on page 4 9 Tools Diagnostics E Printhead Consumables B 4 Figure 8 4 Diagnostics Page Rev AC Diagnostics 8 43 Illustrated Parts List The illustrations and the associated tables provide detailed info
86. e EEPROM of the system database Check whether EEPROM has been inserted correctly Check connection between ACC and Panel lO Check whether EEPROM of Panel IO has been inserted correctly This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10002 Backup of system database was loaded Several entries are missing in the system database Therefore the backup of the system database has been loaded Check entries of system database and correct if necessary This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10003 Cannot write all to the backup of the system database Not enough space left on the MMC MultiMediaCard Check space on MMC and reduce application database if necessary 1024 Bytes are required Remove unused fonts and templates from the laser system This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10004 Cannot write to system database Faulty connection to the EEPROM of the system database Check the state of the system
87. e When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19204 Product registration does not exist The product registration required by a template is missing Assign an existing product registration to the template or add the required product registration to the database When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19205 At least one index level does not exist in the parameter set The template uses an index level which does not exist in the parameter set Add the missing index level to the parameter set or assign an existing index level to all elements of the concerned template When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19210 The direct marking cannot be carried out Faulty connection between PC and ACC Check the Ethernet connection between PC and ACC When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19301 The template sequence does not contain any template Template sequences are not supported yet When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19302 A template in the template sequence does not exist Template sequences are not supported yet When the fault is corrected a Clear button will appear below Cle
88. e key switch by software please open the hardware key switch first Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E26100 LHC has unexpected internal errors Program error Contact your local Service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E29009 Beam shutter error Defective beam shutter Defective cable between beam shutter and LHC Check beam shutter and cable This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings 8 40 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E33301 Power supply Inadmissible terminal voltage While startin
89. e reference not supported by this printer Use Clarisoft to set the Reference Date for all Calculated Dates to Current Date Then download the corrected file to the printer Press the Clear button below to clear this fault message E1224 Invalid Job File Invalid Date Rounding The Job file contains a date with a rounding calculation that is not supported by this printer Use Clarisoft to remove the Rounding for all Calculated Dates Then download the corrected file to the printer Press the Clear button below to clear this fault message E1225 Invalid Job File Invalid Counter The Job file contains a counter that is not supported by this printer Use Clarisoft to remove all counters from the job Then download the corrected file to the printer Press the Clear button below to clear this fault message E1226 Invalid Job File Invalid Price The Job file contains a price field that is not supported by this printer Use Clarisoft to remove all price fields from the job Then download the corrected file to the printer Press the Clear button below to clear this fault message E1227 Invalid Job File Invalid Transmitted Field The Job file contains a transmitted field that is not supported by this printer Use Clarisoft to disable the Transmitted Field option for all fields in the job Then download the corrected file to the printer Press the Clear button b
90. e together Press the Clear button to enable printing to be restarted E1008 Power Failure Detected A serious drop in the mains power has been detected In order to protect the printer from damage the high voltage circuits have been switched off You must now repower the printer in order to resume printing If the problem persists contact your maintenance engineer or local service representative E1009 Corrupt MAC Address The MAC address of this printer is corrupt and the printer cannot function without a valid MAC address Contact your maintenance engineer or local service representative who will be able to correct this problem Table 8 4 Error Messages and Warnings 8 6 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E1010 Invalid Line The line selection inputs have requested a line that is not configured Use CLARITY Configuration Manager to check that the correct number of lines have been setup for this system Also check that the line selection inputs are connected properly Press the Clear button below to clear this warning message E1011 Production Disabled A request to print a product has been received for a line that production has been disabled on Please press the Job button on the home screen and check that the line configuration is correct Press the Clear button below to clear
91. e active AN Warning PERSONAL INJURY Danger to Eyes and Skin People within the area of the laser must wear suitable safety goggles against direct reflected or diffusely scattered laser radiation Rev AC Starting the Laser Marking 5 23 CLARITY Laser Controller System Manual AN Warning PERSONAL INJURY Never expose flammable materials to laser radiation Always ensure appropriate shielding of the laser beam Errors during marking on flammable materials e g paper might cause fire Take suitable safety measures by installing smoke or fire detectors N Warning PERSONAL INJURY Never expose reflecting surfaces to laser radiation The reflected laser beam may cause the same dangers in individual cases even greater dangers as the original laser beam A Warning PERSONAL INJURY Never expose unknown materials to laser radiation Some materials e g polyethylene polypropylene glass are easily penetrated by the laser beam although they seem to be opaque to human eye N Warning PERSONAL INJURY Danger of explosion Make sure that the laser area is free of explosive materials or vapors Note For more safety information refer Laser System Manual 4 Touch the Run button to start marking 5 24 Starting the Laser Marking Rev AC CLARITY Laser Controller System Manual Stopping the Marking 1 Touch the Stop button The status bar changes to OFFLINE 2 To disable the laser sy
92. e laser stop switch This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E19314 SL501 Laser Extension Board cannot be identified No or incorrect board connected to the ACC Check connection to SLEB This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E19413 The interlock circuit has been opened The interlock circuit has been opened Close the interlock circuit E19502 Suction control error Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19503 The filter is full Check the filter condition and replace if necessary When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 39 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E19504 The filter is full Check the filter condition and replace if necessary When the fault is corrected a Clear button will appear below C
93. ecified by the Minimum and Maximum user concession Use Clarisoft to correct this error in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1105 Invalid Job File Multiple Transmitted Fields The Job file is invalid and needs to be corrected using Clarisoft A Transmitted Field attribute was found on more than one field Only one field can be tagged as the transmitted field Use Clarisoft to correct this error in the Job file Then download the corrected file to Clarity Press the Clear button below to clear this fault message E1200 Invalid Job File invalid barcode character The Job file is invalid and needs to be corrected using Clarisoft A barcode in the Job file contains characters which are not in the character set of the barcode type being used Use Clarisoft to check and correct the barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1201 Invalid Job File invalid barcode check digit The Job file is invalid and needs to be corrected using Clarisoft The check digit supplied for a barcode in the Job file is invalid Use Clarisoft to check and correct the barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1202 Invalid Job File EAN barcode out of specification The Job file is in
94. eck voltage adjust setting if necessary 30V to 48V to RF PSU or exchange power supply module If the voltage is OK check power contacts in the laser head This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00202 Laser overtemperature Insufficient cooling Broken umbilical Check cooling system Check signal cable between ACC and laser heatswitches When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 19 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E00203 Unknown laser beam source Incorrect entry in system database OS sends invalid laser type ID Contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00204 General error Fault in the RF circuit Voltage too high low Check voltage adjust setting if necessary 30V to ACC3 48V to RF PSU or exchange power supply module Check umbilical for electrical continuity
95. ed dates in the job Then download the corrected file to the printer Select a valid Job and then press Clear button below to clear this fault message E1500 Log File Corruption Corruption has been detected in the log file Please navigate to Tools Diagnostics Control Log Files for more details Press the Clear button below to clear this warning message E1501 Log File Space Critical The available space for logging has reached a critical level Please archive the log file or delete unnecessary files from the Job database to free up some space This fault message will clear automatically when the free space is increased E1502 Log File Space Limited The available space for logging becoming limited Please archive the log file or delete unnecessary files from the Job database to free up some space Press the Clear button below to clear this warning message E1503 Logging Space Exhausted The available space for logging is exhausted Please archive the log file to free up some space Press the Clear button below to clear this fault message Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 13 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E1504 Log File Save Failed Failed to save log file information Some log file information has been lost Press the Clear button below to cle
96. ed a clearable level 1 error Determine the cause for the error and rectify When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings 8 16 CLARITY Error Messages and Warnings Rev AC CLARITY Laser Controller System Manual Error No Report on CLARITY Operator Interface E6255 Laser Error Level 2 The laser marking head has reported a clearable level 2 warning Determine the cause for the warning and rectify When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6256 Laser Shutterlock Open The shutter on the laser marking head has been opened Ensure that the laser marking head can be operated safely and close the shutter When the fault is corrected a Clear button will appear below Clear this fault and resume operation E00001 Parts of the marking are beyond the marking field Parts of the marking are beyond the user defined marking field Reduce size of the overall message by reducing the scaling factor Expand marking field to maximum size Select objective with higher focal length thereby increasing the maximum possible marking field When the fault is corrected a Clear button will appear below Clear this fault and resume operation E00002 Incomplete marking product movement too fast Product has exited the marking field before marking could be comp
97. eived unknown Yes Yes command from AOS E00103 Timing error SP Yes Yes E00104 AOS data transfer delayed Yes Yes 00105 Marking aborted product No Yes movement too fast E00200 Laser not ready Yes Yes E00201 Laser supply voltage too high Yes Yes or too low E00202 Laser overtemperature Yes Yes E00203 Unknown laser beam source Yes Yes E00204 General error Yes Yes Table 6 5 Fault Table 6 16 Availability Fault Table Rev AC CLARITY Laser Controller System Manual Description of Fault Laser System Down Operational Downtime time faults impacting faults impacting the the laser availability ULT CREE VELLE JT ET E00205 Internal cooling circuit Flow No Yes too low E00206 RF circuit VSWR fault Yes Yes E00207 RF circuit Overmodulation Yes Yes E00208 RF circuit Incorrect RF PSU Yes Yes power E00209 Back reflection Yes Yes E00210 Red laser emission LED Yes Yes defective Hardware error E00211 Defective element in laser Yes Yes supply circuit E00212 Wrong LIC detected Yes Yes E00213 Wrong HIC detected Yes Yes E09000 Marking head Temperature No Yes of FM MHI assembly group too high E09001 Marking head Supply voltage Yes Yes too low E09002 Marking head Yes Yes Overpositioning of X mirror 09003 Marking head Yes Yes Overpositioning of Y mirror E09004 Marking head Overcurrent X Yes Yes mirror E09005 Marking head Over
98. elow Clear this fault and resume operation E10103 Key not found in system database The database entry requested via Ethernet does not exist Check program which is sending the command When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings 8 26 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E10104 Database write error Transmission error while transmitting a database object via Ethernet or version conflict between database object and AOS Repeat transfer check version When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10105 Database read error Database entry required for executing a command received via Ethernet is missing Check the database entries When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10106 Template contains no data Template information has been requested via Ethernet The corresponding template contains no data Check template and save it When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10107 Template does not exist Template information has been requested via Ethernet The corresponding template does not exist in the application d
99. elow to clear this fault message E1228 Invalid Job File Invalid Graphic Field The Job file contains a graphic field that is not supported by this printer Use Clarisoft to remove all Logo and Drawing fields in the job Then download the corrected file to the printer Press the Clear button below to clear this fault message E1229 Invalid Job File Invalid Graphic The Job file contains a graphic field that is not supported by this printer Use Clarisoft to remove all Logo fields in the job Then download the corrected file to the printer Press the Clear button below to clear this fault message E1230 Invalid Job File Invalid Drawing The Job file contains a Drawing field that is not supported by this printer Use Clarisoft to remove all Drawing fields in the job Then download the corrected file to the printer Press the Clear button below to clear this fault message Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 11 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E1231 Invalid Job File Invalid Paragraph Field The Job file contains a Paragraph field that is not supported by this printer Use Clarisoft to remove all Paragraph fields in the job Then download the corrected file to the printer Press the Clear button below to clear this fault message E1232 Invalid Job
100. en position Note On connection to the Laser System the status bar will stay at shutdown Note Once the manual keyswitch or software keyswitch is enabled the starting up message will be displayed and the unit will move to OFFLINE mode Rev AC AC 10 11 12 CLARiTY Laser Controller System Manual Confirm that the laser system and controller are connected When the units are connected the Printhead Not Present note on the home screen disappears Note Warning E10517 appears Clear the warning by selecting the status bar and following the instructions Note If the units do not connect after a short period of time refer to the troubleshooting section Printhead Absent on page 8 5 Navigate to Tools gt Setup gt Control gt Date and Time to setup the correct date and time Perform the line setup For information on line setup refer Line Setup on page 5 11 Note Always make sure that the Line Set up on the controller is as per the requirement of the PRODUCTION line This is important especially in situations where the controller is connected to the laser which was set up using a different means or if the Laser is being replaced or when the laser is not connected to a line Adjust the print position as required For information on print position refer Print Position on page 5 4 Select a job and start the laser marking For information on selecting a job and starting the marking refer Select
101. ent This should be done before attempting any maintenance or repair on any part of the product N Warning PERSONAL INJURY Ensure that any cables from the controller are secured to avoid chance of movement into walkways and becoming a trip hazard A Warning PERSONAL INJURY There will be sections of the Printed Circuit Board PCB that will be permanently powered via the on board lithium battery therefore it is essential that the board should never be placed onto nor stored in or on any conductive surface including conductive plastic bags etc as this would flatten the battery and or potentially result in battery overheating The battery is not to be replaced by the operator Do Not Remove Warning Label N Warning PERSONAL INJURY Do not under any circumstances remove or obstruct any warning caution or instruction labels present on the controller If any part of these labels become damaged worn or removed they must be immediately replaced Rev AC Equipment Safety Guidelines 2 3 CLARITY Laser Controller System Manual Grounding and Bonding AN Warning PERSONAL INJURY Always prevent static discharge from occurring Use proper Grounding and Bonding methods Always bond conductive equipment together with approved cables to maintain them at the same potential and minimize static discharge Only use videojet approved metallic service trays and ground cables Communications A Caution EQUIPMENT DAMAGE Ensure
102. eration Aborted The operation of the printer was intentionally aborted by a host control system When ready to do so the host control system will clear this abort condition and then this fault message will automatically clear and the printer will resume operation E1003 Realtime Clock Fault There is a problem with the Real time Clock which is required for the system to operate correctly E1004 Backup battery is flat The battery which powers the printer s clock is flat This means that the date and time the currently selected Job and some performance data will be lost when the printer is switched off E1005 Print Limit Exceeded The current Job was selected with a print limit i e a limit on the number of times the Job can be printed This limit has been reached but the printer has received a further print signal that would have exceeded the limit This error will become clearable after selecting a new job Alternatively a Job selection command or variable data update from an external source will also make this error clearable E1006 Image Update Failure CLARITY was unable to update the image that will be printed next This usually occurs because products are too close together Press the Clear button to enable printing to be restarted E1007 Image Update Failure CLARITY was unable to update the image that will be printed next This usually occurs because products are too clos
103. eter and is automatically sent to the Laser a SHUTDOWN gt Mark Set Parameters Mark Intensity 412 e Min 0 3 Max 10096 5 6 Default NS 8 9 lt gt v Cancel OK Figure 5 7 Data Entry Completion When you navigate away from Mark Sets Parameters screen you will be prompted to either save or discard the changes made to the parameters Note The changes to mark sets will be saved for the job until it is removed or reloaded into the controller Rev AC CLARITY Laser Controller System Manual Line Setup Rev AC Note The controller must not be in OFFLINE mode while transferring line setup changes to the laser unit Note Line setup option is not available in RUNNING mode Note On power cycle the line setup graphic will display the equivalent top side graphic However the actual line setup will not change Note Whenever the physical setup is changed ensure that the line setup is also updated on CLARiTY If an unsupported laser system is connected a fault will be displayed Power off the laser system and the controller Contact Videojet Technologies Inc at 1 800 843 3610 for all customers within the United States Outside the U S customers should contact their Videojet Technologies Inc distributor or subsidiary for more information Navigate to Tools gt Setup gt Printhead gt
104. eters where maximum and minimum values for these parameters are unique to each laser coding marking system Selecting mark set allows the user to adjust the job values for the particular marking job For more information refer Mark Sets on page 5 7 Note If no job is selected or a job has been created outside CLARISOFT without a valid mark set the mark set list will be empty gj Print Position Mark Set Default A lt gt Ni Cancel OK If a job does not have a mark set available perform the following action 1 Load the job into CLARISOFT and identify the Mark Sets available for the target laser 2 Associate the appropriate Mark Set with each field of the job 3 Once complete transfer the job to the CLARITY Controller where it can be selected for marking Table 5 1 Print Position Page parameters Continued 5 6 Print Position Rev AC Rev AC CLARITY Laser Controller System Manual Mark Sets Mark Sets button displays the parameters of the current job see Figure 5 5 A SHUTDOWN J 4 9 Print Position Mark Set 2D Matrix on Paper Default QR on Paper Text on Paper Vv Cancel OK Figure 5 5 Mark Sets Note The mark set s associated with the loaded job is displayed Print Position 5 7 CLARITY Laser Controller System Manual Mark Sets Parameters The set of available parameters for the selected M
105. figuration of the connected laser marking head You may encounter marking field warnings or incomplete print Use the scaling and positioning adjustments to adjust the message When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6250 Laser in Service Mode The laser marking head is in Service Mode This warning will clear automatically once the laser marking head is no longer in Service Mode E6251 Laser Interlock Open The safety interlock for the laser marking head has been opened Ensure that the laser marking head can be operated safely and close the interlock When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6252 Laser Interlock Timeout The timeout for the safety interlock of the laser marking head has expired Ensure that the laser marking head can be operated safely and close the interlock When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6253 Laser Fatal Error The laser marking head has reported a fatal error Determine the cause for the fatal error and rectify This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E6254 Laser Error Level 1 The laser marking head has report
106. fter a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10918 A problem with the RF driver file occurred The RF driver file on the MMC MultiMediaCard is faulty Check RF driver file on MMC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings 8 36 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E10919 A driver error prevents triggers being transmitted from the CAN bus Internal error Contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10920 A driver error prevents control of the red emission LED Internal error Contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10921 Less
107. fter a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00208 RF circuit Incorrect RF PSU power Faulty RF PSU Faulty ACC interface board or faulty cables No jump link on JP1 on ACC interface board Check RF PSU operation Check ACC interface board operation This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings 8 20 CLARITY Error Messages and Warnings Rev AC CLARITY Laser Controller System Manual Error No Report on CLARITY Operator Interface E00209 Back reflection Closed beam path laser light is reflected back into the laser This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00210 Red laser emission LED defective Hardware error The red laser emission LED is not functioning Please check and replace the LED This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00211 Defective element in laser supply circuit Hardware e
108. g Short circuit at the output of the power supply During operation 1 Defective pump chamber 2 Electr malfunction of cooler Check wiring between power supply and diode for short circuit This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E34200 Power supply Overtemperature The temperature within the power supply module is too high Check cooling system This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E34201 Internal cooling circuit Temperature above below limit value Internal cooling circuit is faulty A possibly connected external chiller has insufficient cooling power Broken cable of the signal line X6 1 Check internal cooling circuit Check external chiller Check cables This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E34203 driver Temperature error Defective cooling system Broken cable between RF driver and LPC Defective RF driver Check cooling system Check cables Exchange RF driver This fault cannot be cleared di
109. ges and Warnings Rev AC CLARITY Error Messages and Warnings 8 15 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E6208 Unsupported Date Format Code Date field 1 contains an unsupported date format code Review the field for unsupported laser content in Clarisoft and reload the job When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6209 Unsupported Time Format Code Time field 961 contains an unsupported time format code Review the field for unsupported laser content in Clarisoft and reload the job When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6210 Unsupported Date Rounding Mode Date field 961 is set to an unsupported Date Rounding mode Review the field for unsupported laser content in Clarisoft and reload the job When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6211 Unsupported Barcode Barcode field 961 is of a type that is not supported for inclusion within an XML Template Please remove the barcode field or change it to a supported barcode type When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6212 Mismatch between Job and connected laser marking head This Job has been created for 961 This does not match the con
110. he laser head needs to be mounted to the product for marking Pilot Laser If the pilot laser is available allows the user to set up the laser as needed when selected Table 4 4 Printhead Setting 4 6 Using the Tools Page Rev AC CLARITY Laser Controller System Manual Working with the Consumables Setup Page Navigate to Tools gt Setup gt Consumables Note Consumables page is not available for Laser controller Working with the Control Setup Page Navigate to Tools gt Setup gt Control see Figure 4 5 A HRENEEGHEUINEHESNENE X e Set Screen Orientation Internationalisation Recalibrate Touchscreen Date And Time Communications Contact Information E gjTools Setup Control CLARITY Parameter Archives gt Degrees gt Vv Vi Figure 4 5 Control Page Buttons Description CLARITY Parameters Archives Allows the user to save current laser system configurations and to restore previously saved laser system configurations Note When a USB memory stick is connected to the laser system archives can also be saved or restored to and from the USB drive as well CLARITY Printer Clones Allows the user to create or restore a Clone file to and from the USB memory stick A Clone file contains all of the laser system settings and Job files Note Only present when a USB memory stick is inserted CLARITY Update Allows the user to selec
111. her jobs that are not required Note You can touch Select All to remove all the jobs from the list The job preview will not be displayed if more than one job is selected 9 Touch the Home icon to return to the home page Turning Off the Controller Turn OFF the controller mains power switch To power off the laser system follow the instructions in the Laser System Manual 5 32 Turning Off the Controller Rev AC Additional Controller Operations This chapter contains the following topics Availability Availability fault table User editable fields Touch to edit Production audit log How to update controller software How to set the screen orientation How to create a job CLARITY power saving Availability Introduction Availability is a measurement of equipment uptime It is the amount of time that the equipment is ready to run when required by production This is one of the three key metrics of OEE The Availability tool helps to isolate operational versus laser system issues and allows the user to track the laser system downtime and view the downtime statistics The pareto of faults that allows the analysis of runtime measurement data helps the user to understand and eliminate the more frequent causes of both laser system and operational downtime The availability shows two basic availability metrics simultaneously Laser system Availability Operational Availability Rev AC Availability 6
112. ic safety information is listed throughout this manual in the form of Warning and Caution statements Pay close attention to these statements as they contain important information that help in avoiding potential hazards to yourself or to the equipment Warning The warning statements indicate hazards or unsafe practices that can cause severe personal injury or death They have a triangular symbol with an exclamation mark to the immediate left of the text They are always preceded by the word Warning They are always found before the step or information referring to the hazard For example A Warning PERSONAL INJURY electrical wiring and connections must comply with applicable local codes Consult the appropriate regulatory agency for further information Rev AC Content Presentation 1 3 CLARiTY Laser Controller System Manual Caution The caution statements indicate hazards or unsafe practices that result in equipment or property damage They have a triangular symbol with an exclamation mark to the immediate left of the text They are always preceded by the word Caution They are always found before the step or information referring to the hazard For example A Caution EQUIPMENT DAMAGE Read this chapter thoroughly before attempting to install operate service or maintain this equipment Notes Notes provide additional information about a particular topic For example Note You can set the pas
113. in the Job file contains data that is out of range e g an hour field set to 25 ora month field set to 13 Use Clarisoft to check and correct the EAN128 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1209 Invalid Job File EAN barcode out of specification The Job file is invalid and needs to be corrected using Clarisoft An EAN128 barcode field in the Job file contains an application identifier that requires a digit to specify the position of the decimal point but this digit is not present Use Clarisoft to check and correct the EAN128 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1210 Invalid Job File EAN barcode out of specification The Job file is invalid and needs to be corrected using Clarisoft An EAN128 barcode field in the Job file contains an application identifier that requires a check digit but this check digit was either missing or invalid Use Clarisoft to check and correct the EAN128 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1211 Invalid Job File EAN barcode out of specification The Job file is invalid and needs to be corrected using Clarisoft An EAN128 barcode could not be rendered at a size of 165mm or less which is the maximu
114. information contact Videojet Technologies Inc Refer to Chapter Support and Training for the contact information The replacement instructions are available for the parts included in the following table Spare Part Liquid Crystal Display LCD Touch Screen Printed Circuit Board PCB Controller Spares Main Switch Assembly Power Supply Unit Table 7 1 Available Instructions Replacement Instructions 7 1 CLARITY Laser Controller System Manual Information on Care f the display is soiled it can be cleaned using a commercially available screen cleaning wipe Ensure any moisture is removed immediately to avoid staining or damage to the touch screen Maintaining the Power Supply This section contains the information on how to replace the fuse Replacing the Mains Fuse The fuses are the only user serviceable parts in the power supply unit To replace the mains fuse proceed as follows 1 Carefully remove the fuse holder see Figure 7 1 A Figure 7 1 Fuse Holder removal Fuse Holder 2 Replace the 5 A fuse if it is defective 3 Refit the fuse holder in its original position 7 2 Information on Care Rev AC CLARITY Laser Controller System Manual Maintaining the Controller Inspection Check point Frequency Measures Controller Check if the touch screen is As Required Clean the touch screen by wiping with a dry clean soft cloth or cotton pad
115. ing a Job for Marking on page 5 8 and Starting the Laser Marking on page 5 23 respectively Note If the job is not downloaded correctly refer to Job Download Failure on page 8 5 Note Before marking follow the safety instructions as mentioned in the Laser System Manual How to Setup the System 3 7 CLARITY Operating System This chapter contains the following topics Introduction Using the home page Using the tools page How to set the passwords Introduction CLARITY is an icon based operator control system It has an easy to use touch screen and most areas of the display are active All technical aspects of the laser system setup and control are accessed through the Tools button Figure 4 1 on page 4 2 shows the home page of the CLARITY operator control system Rev AC Introduction 4 1 CLARITY Laser Controller System Manual Using the Home Page 8 Loggut Level 2 17 21 31 10 2013 E 80 CHARACTER TEST 2 original JOB E 4 S _ i Performance Throughput Op m Batch Count 2 5 o Total Count 7238571 1 Controller Status Bar 2 Tools Button 3 Current Job Details Bar 4 Performance Information 5 Print Position 6 System Control Buttons 7 Home Button 8 Job Select Button Figure 4 1 CLARiTY Home Page Button Description Controller Status Bar Provides information about the status of the controlle
116. ing parameter Review and optimize mark set parameters When the fault is corrected Clear button will appear below Clear this fault and resume operation E09005 Marking head Overcurrent Y mirror The current consumption of the Y mirror is too high Check Y mirror Check wiring in the marking head Can be caused by overpositioning Reduce jump speed marking parameter Review and optimize mark set parameters When the fault is corrected Clear button will appear below Clear this fault and resume operation E09006 Marking head No X mirror connected The X mirror is not connected correctly to the FM MHI board A cable might be loose or broken Check connection between X mirror and FM MHI board When the fault is corrected a Clear button will appear below Clear this fault and resume operation E09007 Marking head No Y mirror connected The Y mirror is not connected correctly to the FM MHI board A cable might be loose or broken Check connection between Y mirror and FM MHI board This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings 8 22 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E0900
117. inued Rev AC CLARITY Laser Controller System Manual Menu Options 12 115200 Value Min Max Unit Comments FlowControl 0 None 1 Software 2 Hardware Usage 0 None 1 Text Commu nications 2 CLARITY 5 Transmitted Field Database Location 0 Local 1 Remote Select the required location for the job files EnableUserTest Print 0 No 1 Yes Job Selection Mode 0 Product Code 1 Tiered Logging IncludeJob Events 0 No 1 Yes LoggingMode 0 None 1 Normal PowerSaving Mode 2 Advanced 0 None 1 Minimal 2 High 3 Full Select the required power saving mode for the controller interface Table C 1 CLARITY Configuration Manager Continued C 7 Rev AC Menu CLARITY Laser Controller System Manual Options Value Min Max Unit Comments Servicelnformation AddressLine1 0 99 No of Characters AddressLine2 0 99 No of Characters AddressLine3 0 99 No of Characters AddressLine4 0 99 No of Characters Customer 0 99 No of Name Characters PrinterLoca 0 99 No of tion Characters SerialNumber 0 99 No of Characters Telephone 0 99 No of Number Characters ShowJobDescrip 0 No 1 Select yes to show the job tionOnHome description if p
118. isplays the list of user editable fields so that you can select one When you touch OK at the final field for this job and all the check boxes are checked the user interface shows you the preview of the image At the preview perform one of the following f youare satisfied with the image and you want to run the new job touch OK Products will be printed with the new image until you make further changes or select a new job If you are not ready to print the job you can leave this screen as it is You can touch OK at a later stage to select the job at that time User Editable Fields 6 27 CLARITY Laser Controller System Manual If you want to step back through the job select screens to make alterations to the variable data touch Cancel To cancel the job selection altogether touch Home a button Touch To Edit To update and change user fields quickly and easily in a printing job the user can use the Touch To Edit feature Note Touch to Edit feature is turned off by default and needs to be activated in Clarity Configuration Manager 1 Select the Current Job Details Bar to display the job preview a SHUTDOWN Eq 4 9 TIJ Text DefaultText DefaultText 3 18 03 2013 DefaultText 2 FixedText 0 00 Figure 6 18 Message preview Touch to edit 2 Touch the button 6 28 Touch To Edit Rev AC AC CLARITY Laser Contro
119. jump This value ranges from 500 to 40000 Jump Delay Allows the user to enter the jump delay in microseconds us It is the delay between the end of a jump and the start of the marking process This value ranges from 0 to 5000 Mark Intensity Allows the user to enter the mark intensity in percentage 96 It is the output Mark Intensity through the current value with 100 corresponding to the maximum Mark Intensity of the laser This value ranges from 0 to 100 Laser On Delay Allows the user to enter the laser on delay in microseconds us It is the delay between the attainment of the start position of a stroke and the switching on of the laser This value ranges from X to 1000 Where X 20 Jump Delay gt 1000 Laser Off Delay Allows the user to enter the laser off delay in microseconds us It is the delay between the attainment of the end position of a stroke and the switching off of the laser This value ranges from 0 to 1000 Table 5 2 Mark Sets parameters Continued Print Position 5 9 CLARITY Laser Controller System Manual 5 10 Print Position Data Entry If a mark sets parameter button is selected it displays a Data Entry screen see Figure 5 7 showing the current value and the permitted range max and min that the input value takes If you modify a parameter by selecting the OK button on the Data Entry screen the new value is stored in the CLARiTY param
120. k the bus terminals of the customer interface Check wiring of CAN bus When the fault is corrected a Clear button will appear below Clear this fault and resume operation E58101 Customer interface Cl CAN bus OFF The CAN bus has not been connected correctly to the bus coupler of the customer interface Check wiring of the CAN bus When the fault is corrected a Clear button will appear below Clear this fault and resume operation E58102 Customer interface Cl CAN bus transmission buffer overflow The CAN bus has not been connected correctly to the bus coupler of the customer interface Check wiring of the CAN bus When the fault is corrected a Clear button will appear below Clear this fault and resume operation E58103 Customer interface Cl CAN bus receiving buffer overflow Internal error of bus coupler Exchange bus coupler When the fault is corrected a Clear button will appear below Clear this fault and resume operation E58104 Customer interface Cl CAN bus incorrect PDO length Internal communication error Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E58105 Customer interface Cl Sync of CAN bus delayed or failed The CAN bus has not been connected correctly to the bus coupler of the customer interfac
121. l availability data based on Availability the proxy in use for the calculation that is Power On time or Running time Table 6 1 Availability Page options 6 6 Availability Rev AC AC CLARITY Laser Controller System Manual Option Description Production Time Allows laser system availability calculation to Proxy change between user selected operating modes that is either running or laser system on mode Proxy choice ensures the calculation of availability matches the operating mode of user The operational availability column in the Avail ability page see Figure 6 3 shows the proxy selected by the user Export to USB Allows the user to export the event log to USB Stick The UI will take the user through the steps required to download to USB Touch the cell to view the Fault Pareto page for the selected availability data The page displays the fault type downtime and fault frequency see Figure 6 4 Shows that further information is available Table 6 1 Availability Page options Continued amp OFFLINE x wWPerformance Availability Fault Pareto E Current Month Operational Availability Power 98 8 Fault Type Downtime mmm ss Frequency eg Maa head Temperature of 0 50 1 gt assembly group too high 10813 No encoder connected 0 14 1 gt E10907 The customer interface Cl 8 04 1 gt indicates an external error A 4
122. l has been received for a product without any line selection 1 Check if the line selection system is functioning correctly 2 Touch the Clear button to clear this fault message Printhead Absent No communication between laser system and CLARITY configuration manager 1 Check cable connections 2 Restart laser system and controller 3 Check IP address Navigate to Tools Diagnostics Control Communications TCP IP If IP address is not at default 192 168 1 1 or as required navigate to Tools Setup Control Communications IPreset and follow the instructions to reset the IP address to default Job Download Failure Refer to CLARISOFT manual and update correct issues Touch the Clear button to clear this fault message Table 8 3 Additional Faults Rev AC Additional Faults 8 5 CLARiTY Laser Controller System Manual CLARITY Error Messages and Warnings Error No Report on CLARITY Operator Interface E1000 Job Update Failure The printer was unable to update the current Job before the next print was required This usually occurs because products are too close together Press the Clear button to enable printing to be restarted E1001 Count Limit Reached One or more of the counters in the image has reached the end value set in the image design Please select a new Job and press the Clear button to enable printing to be restarted E1002 Op
123. lear this fault and resume operation E19505 The Safety circuit is open Close the safety circuit to continue When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19506 The front panel keyswitch is open Close the keyswitch to continue When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19507 The customer interface Cl keyswitch is open Close the keyswitch to continue When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19508 The front panel stop button was pressed Release the stop button to continue When the fault is corrected a Clear button will appear below Clear this fault and resume operation E19509 Safety connector has a signal on unused line The configured safety circuit does not match the circuit attached Contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E19510 The Key switch is closed It can not be opened by software In systems with combined hardware sofware key switch the key switch cannot be opened by the software if the hardware key switch is closed To control th
124. ler and the laser marking system and confirm normal operation E10514 FM MHI download error A program has to be transmitted from the MMC to the FM MHI During this download an error occurred Check connection between ACC and FM MHI Check FM MHI Check ACC Reboot This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10515 FM MHI download File is missing The required file does not exist on the MMC MultiMediaCard Faulty connection between ACC and FM MHI Copy the missing file to the MMC Check connection Check for latest version of Qmark This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10516 The marking head is not connected Faulty connection to the marking head No marking head connected Check connection between ACC and FM MHI Connect marking head This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 31 CLARiTY Laser Controller System
125. leted Increase distance of start delay Usually this requires the sensors to be adjusted Optimize mark set parameters so that the marking can be executed faster Reduce size of the message so that it can be marked faster Select a speed optimized single line font If possible increase the marking field by selecting a lens with a longer focal distance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E00003 AOS does not send data after trigger gt 10ms After the trigger it took more than 10ms before the AOS sent marking data Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E00004 Delayed data from the AOS During the marking process it took more than 500us before the AOS sent new data If the AOS does not send the vector data as fast as they are marked artificial pauses are added to the marking This causes the laser to be switched off even within a vector stroke and switched on again as soon as data is available In this situation Laser On Delay and Laser Off Delay are used Increase the values of the start delay or trigger delay and the distance between the marking field and the product sensor This way more data can be processed before the marking execution is started When the fault is corrected a Clear button wi
126. ll appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 17 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E00005 Trigger lost Trigger queue overflow a new trigger had to be rejected That means that the trigger signals are coming in faster than they can be processed The trigger queue is a buffer for trigger signals If it is full and more signals are coming in this warning is displayed Since the trigger signals are coming faster than they can be processed the marking time has to be reduced If the marking time cannot be reduced any more the throughput has to be reduced This may also be caused by mis triggers or double triggers due to dirty product detector optics Clean the lens of the product detector and recalibrate it for your product Ensure the blocking parameter in Line Setup is set to 9096 of the product width When the fault is corrected a Clear button will appear below Clear this fault and resume operation E00006 Incorrect index step selected Internal error A not initialized index step has been selected The system uses the previously selected index step Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E00007 Debug
127. ller System Manual 3 Thejob opens with the user editable fields highlighted Note Only jobs that have user editable fields can be edited using Touch to Edit feature These are set up in CLARISOFT during message creation a SHUTDOWN E 9 TIJ Text Touch To Edit 1 a Deraultrext DefaultText 3 18 03 2013 DefaultText 2 FixedText 0 00 A gt Cancel SE Figure 6 19 User Editable Fields Highlighted 4 To edita user field touch the user field 5 The appropriate user field editor based on the user field type is displayed for the update Update the user field as required and touch OK a SHUTDOWN Touch To Edit Edit Fields Field00 1 9 USER EDIT lt QeWHeEPRETHY PUP FoPR 3 2 2 1 2 SEO SE E Cancel OK Figure 6 20 User Field Editor Touch To Edit 6 29 CLARITY Laser Controller System Manual 6 Ifthere are additional user fields repeat step 4 and step 5 for each field 7 Touch OK after editing all the required user fields The job will be updated in the printer and displayed in the current job details bar following the next p
128. m Manual To export Availability Metrics a From Home page navigate to Performance gt Availability see Figure 6 3 on page 6 6 b Select Export to USB c Confirmation page will be displayed see Figure 6 10 o es 3 w Performance vailability Export Export Availability Metrics Ready to export Availability Metrics data to attached USB device A v Cancel OK Figure 6 10 Export Availability Metrics Confirmation d Select OK e On completion success page will be displayed c ee ibility Success S Availability Metrics exported successfully to file AM 00 0f 41 00 e8 cd csv A d OK Figure 6 11 Export Success f Select OK and remove the USB stick 6 14 Availability Rev AC AC CLARITY Laser Controller System Manual To export Event Log a Navigate to Tools gt Diagnostics gt Printhead gt Event Log see Figure 6 7 on page 6 11 b Select Export to USB c Confirmation page will be displayed see Figure 6 12 D PE lt Diagnostics Printhead Event Log Export Export Event Log Ready to export Event Log data to attached USB device OK Figure 6 12 Export Event Log Confirmation d Select OK e On completion success page will be displayed A ESUESNGEEHNEREESESI X 8 Printhead9Event Log Export Success Event Log exported successfully to files EL 74 de
129. m length for this type of barcode Use Clarisoft to check and correct the EAN128 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 9 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E1212 Invalid Job File barcode length incorrect The Job file is invalid and needs to be corrected using Clarisoft A barcode field in the Job file does not have the expected number of characters Use Clarisoft to check and correct the barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1213 Invalid Job File barcode out of limits The Job file is invalid and needs to be corrected using Clarisoft A barcode field in the Job file overruns the edge of the image and it is not possible to extend the image area to accommodate the barcode Use Clarisoft to check and correct the barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1214 Invalid Job File Invalid Checksum Data The Job file is invalid and needs to be corrected using Clarisoft A field in the Job file uses a checksum e g an EAN 13 barcode with a price verifier digit but the data supplied to calcul
130. mplate sequence does No Yes not contain any template E19302 The template in the template No Yes sequence does not exist E19303 The heads of templates of a No Yes Table 6 5 Fault Table Continued 6 22 Availability Fault Table Rev AC Description of Fault CLARITY Laser Controller System Manual Laser System Down time faults impacting the laser availability Operational Downtime faults impacting the e eT LEOTE TREE E19304 The product registrations of No Yes templates of a template sequence must be identical E19305 Product registration does not No Yes exist E19306 Defective template in the Yes Yes template sequence E19307 The circuit for external laser No Yes enable has been opened E19308 Cannot select beam source Yes Yes E19309 The clock had to be restarted Yes Yes Please set the time E19311 Fiber Laser Extension Board Yes Yes has not been detected E19312 Fiber Laser Overtemperature Yes Yes E19313 The laser stop switch has No Yes been pressed E19314 SL501 Laser Extension Board Yes Yes cannot be identified E19413 The interlock circuit has been No Yes opened E19502 Suction control error Yes Yes E19504 The filter is full No Yes E19509 Safety connector has a signal No Yes on unused line E26100 LHC has unexpected internal Yes Yes errors E29009 Beam shutter error Yes Yes E33301 Power su
131. n off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10915 A CAN node does not react after download or software reset Defective connections Defective CAN node Check wiring of CAN bus Check corresponding CAN node This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10916 Faulty download to node Defective wiring of CAN bus The corresponding node is faulty Required program not available on MMC MultiMediaCard Check wiring of CAN bus Check corresponding CAN bus node if necessary update of MDB of the CAN bus node Transmit missing program to MMC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10917 A CAN node signals unsuitable software Defective wiring of CAN bus The corresponding node is faulty Required program not available on MMC MultiMediaCard Check wiring of CAN bus Check corresponding CAN bus node if necessary update of MDB of the CAN bus node Transmit missing program to MMC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system A
132. n the CAN communication Check CAN bus This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E19309 The clock had to be restarted Please set the time The clock did stop and has already been restarted The battery voltage might be too low Set the time If this happens every time after power cycle exchange the battery This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E19311 Fiber Laser Extension Board has not been detected No board or wrong board connected to the ACC Check connection to FLEB This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E19312 Fiber Laser Overtemperature Faulty fan Clogged ventilating slots Check cooling and ambient temperature This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E19313 The laser stop switch has been pressed The laser stop switch has been pressed Releas
133. nce correspondingly usually by moving the sensors farther from the marking field Optimize the mark set parameters so that the marking can be carried out faster Reduce template size so that it can be marked faster Select a speed optimized single line font If possible increase the marking field by selecting a lens with a longer focal distance When the fault is corrected Clear button will appear below Clear this fault and resume operation 00200 Laser not ready Faulty cable to voltage supply of the laser Relay for voltage supply of the laser did not switch No enable for RF PSU 50 W laser only Faulty connecting cable between laser and ACC Check Laser tube LED Laser Ready If it is off after switching the laser on there is no voltage supply of the laser The cause can be a broken cable or a defective relay Check cable and relay and replace if necessary If the laser tube LED is on the cable between laser and ACC might be defective Select a font which has been speed optimized Check cable and replace if necessary 50 W laser system Check 48 VDC to RF PSU Check enable signal Check RF PSU This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00201 Laser supply voltage too high or too low Faulty power supply module or incorrect voltage setting Ch
134. nd Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E1604 No read reported The Barcode Scanner has reported a No Read Consider recalibrating the scanner Press the Clear button below to clear this warning message E1605 Barcode verify queue empty The Barcode Scanner has been gated when there was no barcode to verify Press the Clear button below to clear this fault message E4040 Allowed Login Attempts Exceeded A user enter an incorrect password repeatedly and has been disabled E6200 Job Download failed Download of Job 961 to laser marking head failed Check communication between controller and laser and reselect job for download When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6201 Job Conversion failed Conversion of Job 961 to XML Template failed This indicates that the job may have been taken from a non laser marking system Review the warnings and resolve the issues in Clarisoft and reload the job When the fault is corrected a Clear button will appear below Clear this fault and resume operation E6202 Unsupported Field Type Field 961 is of a type that is not supported for inclusion within an XML Template Review the field for unsupported laser content in Clarisoft and reload the job When the fault is corrected Clear button will appear below
135. nfiguration Angle 0 360 360 degree Consecutive 100000 0 16000000 ms Delay Consecutive 100000 0 16000000 mm Distance Consecutive 0 auto 8 Trigger ale Source 1 trigger 1 raise 2 trigger 1 fall 3 trigger 2 raise 4 trigger 2 fall 5 trigger 3 raise 6 trigger 3 fall 7 program 8 none DistPerRot 1000 0 2147483647 FixedSpeed 1000 0 2000000 mm s Mounting 270 360 360 degree Position PulsesPerRot 2048 0 1000000 Table C 1 CLARITY Configuration Manager Rev AC CLARITY Laser Controller System Manual CLARITY Laser Controller System Manual Menu Options Value Min Max Unit Comments RotDirMonitor 0 left 2 1 right 2 none StartDelay 0 0 16000000 ms StartDistance 0 0 16000000 mm StartTrigger 0 auto 7 SE 1 trigger 1 raise 2 trigger 1 fall 3 trigger 2 raise 4 trigger 2 fall 5 trigger 3 raise 6 trigger 3 fall 7 program StopDelay 0 0 16000000 ms StopDistance 0 0 16000000 mm StopTigger 0 auto 8 SC 1 trigger 1 raise 2 trigger 1 fall 3 trigger 2 raise 4 trigger 2 fall 5 trigger 3 raise 6 trigger 3 fall 7 program 8 none Type 0 No Product 2 Movement 1 Fixed Speed 2 Encoder Line Setup LineSpeed DistancePer 150000 1 10000000 Revolution FixedSpeed 99999 0 300000 mm s
136. nt 149 _ Availability Availability Short Term Speed 0 Short Term Efficiency 0 Long Term Speed 0 PUE Long Term Efficiency 0 Ha Trend Speed 0 Figure 6 2 Performance Rev AC Availability 6 5 CLARITY Laser Controller System Manual Displays the Availability page see Figure 6 3 The user can view simultaneously the laser system availability and operational availability data against the time frame The history of the availability data in the Timeframe column enables the user to correlate seasonal changes affecting availability Performance Availability Timeframe Printer Availability operational Availability ower On time Last 30 days 100 0 gt 99 1 gt Last 90 days 100 0 gt 99 1 gt Current Month 99 896 98 3 A v Production Time Export to USB Figure 6 3 Availability Note Arrows shown in the availability cells indicates the presence of data for drilling down Select the cell to view the specific data for detailed analysis Option Description Timeframe Allows the user to view laser system and operational availability values for different available time frames The history of the availability data enables the user to correlate seasonal changes affecting availability Laser System Shows the laser system availability data Availability Operational Shows the operationa
137. nts of the external text or change the property Prompt Once warning When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10500 Cannot load database The application database and its backup cannot be loaded A new database file has to be written to the MMC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10501 Backup database has been loaded The application database is defective Please save the database Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 29 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E10502 System Message Error during determination of the current template or its variables Probably the database does not contain any templates If the database contains no template create and add a new template and save the database This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10503 The database format has changed Please save system An older database has been loaded by a new AOS Saving the database it is automatically converted to the new
138. o high Reduce number of variables or templates When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10116 Error while reading directory The MMC MultiMediaCard on the ACC cannot be read Check MMC When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 27 CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E10300 Data for initialization cannot be read completely from the database Defective system database or customer database The MMC MultiMediaCard is full or damaged Check whether the EEPROM has been inserted correctly Check connection between ACC and Panel JO Check whether the EEPROM of the Panel IO has been inserted correctly This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10301 The parameter set contains inadmissible settings which are automatically adjusted before marking The application database belongs to a different laser system and as such some parameters are out of range for this laser system To avoid the automatic adjustment of the settings you can modify the parameter set manually If you save the corrected pa
139. oard or marking head failure This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10520 A marking head has been identified which is not admitted for this laser type A laser type and marking head mismatch has been detected Please select the appropriate lens installed for this system If you receive this error and the head or laser configuration has not changed it may indicate a hardware failure This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10550 AllprintBasic Syntax error The AllprintBasic command string in the AOS database Config Input contains a syntax error Test the command string on the PC with AllprintBasic correct it and import again via SmartGraph into the AOS database Then reboot the ACC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings 8 32 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface
140. om the Jobs Database To remove jobs that are no longer required proceed as follows 1 Touch the Tools icon on the home page 2 Touch the Database icon on the tools page to open the database page 3 Select the required database internal or external and touch Edit to go to the deletion screen see Figure 5 21 This page contains a list of all the available jobs along with details of the space available for the storage of new jobs OFFLINE X e 1 A Tools Databases Internal 4 Statistics Barcode Control Image Small 3 8kB x Cartridge Test Image TwoHeadStitch Cancel 1 File Select All Delete Figure 5 21 Database Delete Window 4 Touch the name of the job that you want to remove from the list of jobs The job image appears in the preview window Make sure that the job is the one that you want to delete 5 Touch Delete to delete the job Rev AC Deleting a Job from the Jobs Database 5 31 CLARITY Laser Controller System Manual 6 Confirm the job to be removed see Figure 5 22 A OFFHNE x Tools Databases Internal Delete Job Delete Job Are you sure you want to delete the Job Cartridge Test Image ciff Y A lt gt Yes Figure 5 22 Confirmation Screen 7 Touch Yes to remove the job 8 Repeat steps 4 to 7 to remove ot
141. on For Customers in EE EE i For Customers in Canada ere Ee E EE il For Customers in the European ii Support and Training Contact LOTITO o of eh te iii DET OICE POCTAMI WEEN ERN RENS iii C stomer TTAN EE iv Chapter 1 Introduction About th Manual iu Ee ETE A 1 1 Related 5 855 1 1 Language Codes iora eh Ee HR E E EE dE SER 1 1 Content Presentation cv koe kk e Re exo dex RUE RN ES 1 3 Positional 1 3 Units of 1 3 Safety Information aee eur hr Fe oes eRe Lt DEED AS ER 1 3 INO GS d aie et oko ARES AME EINER E ER MERO CREUSE 1 4 Abbreviations and Acronyms 52v co eR RE REC CN 1 4 Chapters in the ch dx Re eee eea EXE Ee EUER PEE 1 5 Chapter 2 Safety ntrod HeHOBL ee Ee ed 2 2 Equipment Safety 2 2 Comply with Electrical Codes 2 2 Electrical 2 2 Do Not Remove Warning 2 3 Grounding and Bonding eae ees 2 4 Communications Rehn DET oe pea POS Lae ees 2 4 Placement of the Controller 2 4 Medical
142. on edit production audit log set screen orientation and Operations CLARITY power saving 7 Maintenance Contains the information on replacement instructions service and maintenance 8 Troubleshooting Contains the operator level diagnostic and troubleshooting procedures 9 IPL Contains the illustrated parts list of orderable parts 10 Appendix A Contains the information about different laser products Ti Appendix B Contains CLARITY Laser Controller specifications 12 Appendix C Contains information about CLARITY Configuration Manager Table 1 3 List of Chapters Rev AC Chapters in the Manual 1 5 Safety Rev AC This chapter contains the following topics ntroduction Equipment safety guidelines Placement of the controller Medical emergencies AN Caution EQUIPMENT DAMAGE Read this chapter thoroughly before attempting to install operate service or maintain this equipment N Warning EQUIPMENT DAMAGE This safety chapter covers the controller safety requirements Please make sure to read the Laser System Manual safety warnings before operating the laser system A Warning PERSONAL INJURY Follow the installation and operating instructions at all times Only trained personnel should carry out maintenance or repair Use of this equipment for any other purposes other than its intended use may lead to serious personal injury 2 1 CLARITY Laser Controller System Manual Introduc
143. ontroller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E09103 Internal error FM MHI not in configuration mode cannot executed command Tried to execute a command in the control mode that is only admitted in the configuration mode Contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings 8 24 CLARITY Error Messages and Warnings Rev AC CLARITY Laser Controller System Manual Error No Report on CLARITY Operator Interface E09104 No data received from the marking head The ACC receives permanently or temporarily no data from the marking head because the connection to the marking head has been separated or the power supply of the marking head failed Check connection between ACC and marking head or MHI Check power supply of marking head This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10001 No data can be read from the system database Faulty connection to th
144. operate the equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules subpart B These limits are designed to provide responsible protection against harmful interference when the equipment is operated in a industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference In such cases the users will be required to correct the interference at their own expense Shielded cables must be used with this unit to ensure compliance with Class A FCC limits The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 00 00345 4 This equipment has been tested and certified for compliance with U S regulations regarding safety by T V S D America CLARiTY Laser Controller System Manual For Customers in Canada Emissions The equipment complies with the Canada ICES 003 04 Class A Safety The equipment complies with Canadian standard C22 2 No 60950 1 This equipment has been tested and certified for compliance
145. ouchscreen gt Date And Time gt Communications gt gt Contact Information Figure 6 23 Control Page Rev AC How to Set the Screen Orientation 6 33 CLARITY Laser Controller System Manual 2 Touch Set Screen Orientation from the list Set Screen Orientation page appears see Figure 6 24 D ORNE X e Tools SetupsControl Set Screen Orientation 4 Degrees 180 j A lt gt V Cancel OK Figure 6 24 Set Screen Orientation 3 Select 0 or 180 degrees depending on your requirement and select OK The screen orientation changes Touch the Home icon to return to the home page How to Create a Job Note Jobs are created offline on a PC using CLARiSOFT software and are then downloaded to the printer For more information refer to CLARiSOFT manual Jobs can be converted from Laser XML format to CIFF format using the CIFF convertor tool Refer to CIFF convertor instructions P N 462487 6 34 How to Create a Job Rev AC CLARITY Laser Controller System Manual CLARITY Power Saving Rev AC This section describes the behavior of the controller in the various power saving states It is possible to set the power saving mode of the controller There are four modes None Minimal High Full The default power saving mode is set to Full e e BZ Archives Value Min Max Gi Code
146. part numbers 2 Make sure that there are no damaged parts If you find any damaged part contact Videojet Technologies Inc to order a new part Rev AC Unpack and Inspect the Laser System and the Controller 3 1 CLARiTY Laser Controller System Manual The Complete Laser System The laser device is classified as a class 4 laser system However the closed laser system up to the beam outlet acts as a class 1 laser system in normal operation Note Normal operation does not include service maintenance and repairs For information on safety setup and operation of the laser coding and marking system refer to relevant Laser System Manual It is important to review and understand the information contained in the Laser System Manual before installing or operating the laser system The laser system must be operated with open laser and or open beam delivery system by specially trained personnel only Make sure that the laser protection rules are always observed CLARITY Laser Controller Connections The CLARITY Laser Controller is designed to operate the Videojet Laser Coding and Marking systems using the CLARITY operating system The user interface is easy to use and minimizes set up and fault finding time The stainless steel controller is a touch screen user interface with an internal power supply You can load jobs modify user editable fields and set print parameters using the touch screen communication and power supply cables
147. plate and used parameters product registration and if existing logos Select template again When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10404 External text Value can be marked only once For an external text the property Prompt Once error has been set and it has been tried to mark an external text with the same value twice Change the contents of the external text or change the property Prompt Once error to Prompt Once warning When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings 8 28 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E10405 The parameter set contains incorrect values Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10407 The beam shutter does not open The beam shutter got jammed or is not identified Improper galvo FM board operation Check the beam shutter Check the shutter cable Check the plug in connections on the board Check galvo FM board operation When the fault is corrected Clear button will appear below Clear this fault and resume operation E10408 The beam shutter doe
148. play 4 When you have corrected the fault the Clear button is activated Press Clear to remove the fault message Fault Messages and Warnings 8 3 CLARITY Laser Controller System Manual Controller Fault Fault CLARITY controller is switched OFF Cause Cable not properly connected to the printer and controller Solution Check and correct Incorrect cable between the printer and controller Check and correct Faulty controller unit Check unit and replace the components as required Table 8 1 Controller Fault Marking Faults Fault The job is not marked Cause The job is empty i e there are no markable objects Such as text time date counter or barcode fields in the job Solution Open load and start a job with mark data in it The job was not loaded to the print memory The job must be loaded to the print memory before marking The status of the laser system is not on Running In order to start marking the START key has to be pressed A shaft encoder is being used but is not activated in the system settings Activate the shaft encoder in the system settings A shaft encoder is being used but it is activated in the system settings of the shaft encoder Deactivate the shaft encoder in the system settings and set the constant marking speed Changes made to the job are not marked The changes were not loaded to the print
149. power Standard IEC region Specific power cord Ethernet Cable RJ45 Ethernet Cable Optional Figure 3 2 Interconnecting Cable 3 4 CLARITY Laser Controller Connections Rev AC CLARiTY Laser Controller System Manual How to Connect the Laser Marking System to the CLARITY Laser Controller To connect laser marking system to CLARITY laser controller proceed as follows 1 Assemble and install the laser marking system according to the instructions provided in the Laser System Manual 2 Setup the working distance according to the instructions provided in the Laser System Manual 3 Mount the CLARITY laser controller as required in proximity to the laser marking system 4 Connect the controller to the laser marking system through the cable provided a RJ45 RJ45 b RJ45 8pin Note The connecting cable is dependent on the laser system available 5 Ensure that product detector and or encoder if required are connected to the laser marking system 6 Connect the controller and the laser marking system to the mains supply The connection of laser marking system to the CLARITY laser controller is complete How to Setup the System Once the connections are made you need to setup the system for marking Prerequisites Before you start the system confirm the following The manual keyswitch is in OFF position where manual keyswitch is available Set the local electrical isolator switch for the laser
150. ppear below Clear this fault and resume operation E10813 encoder connected 1 In the product registration an encoder was selected although no encoder is connected 2 In the product registration an encoder was selected which has been removed during operation Connect encoder or deselect encoder in line setup When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10814 No trigger detector connected 1 In the product registration external trigger was selected although no trigger detector is connected 2 In the product registration a trigger detector was selected which has been removed during operation Connect trigger detector or deselect external trigger in the line setup When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10899 Incomplete marking product movement too slow The marking has been aborted to prevent burning because the conveyor belt is moving too slow or has stopped Please check the conveyor When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10900 General CAN bus error Faulty wiring Strong source of interferences nearby Faulty assemblies Check wiring of CAN bus Eliminate source of interference Replace faulty assemblies This fault cannot be cleared directly Turn off the Laser Controller and the laser marking s
151. pply Inadmissible Yes Yes terminal voltage E34200 Power supply Yes Yes Overtemperature E34201 Internal cooling circuit Yes Yes Temperature above below limit value E34203 RF driver Temperature error Yes Yes Table 6 5 Fault Table Continued Rev AC Availability Fault Table 6 23 CLARITY Laser Controller System Manual Description of Fault Laser System Down Operational Downtime time faults impacting faults impacting the the laser availability operational availability E39009 RF driver VSWR error Yes Yes E39012 Power supply General error Yes Yes Table 6 5 Fault Table Continued User Editable Fields Some jobs contain user editable fields These fields are part of the job that can be changed There are three types of user editable fields e Variable TEXT fields For example they are used for batch codes product names and other text jobs e Variable DATE fields For example they are used for sell by dates Variable COUNTER fields Allows you to modify the starting value for a counter If the selected job has a user editable field the interface prompts the user to review this field and edit if required Note Each field has a check box The check box is unchecked initially As you enter the data and touch OK the user interface automatically checks the box You can proceed to the next step only when all the boxes are checked How to Change the Text and Date Fields To
152. r Starting Up Controller unit establishing communication with the laser marking and coding system Shutdown Laser system is turned on and the keyswitch is disabled Offline Laser system is turned on and keyswitch is enabled Running Laser system is turned on and marking Keyswitch is enabled Allows the user to enable disable marking as requested If warnings or faults are present it allows the user to access and review them when selected Table 4 1 Home Screen Buttons 4 2 Using the Home Page Rev AC CLARITY Laser Controller System Manual Button Description Tools Button Allows the user to access the Tools page and opens the tools menu Current Job Details Bar Displays the actual job being marked Selecting the bar will display the job preview If touch to edit and print position options are enabled selecting the job detail bar will allow the user to access these functions Performance Displays the following laser system performance Information information e Throughput Throughput of the laser system in marking per minute since the current Job was loaded Batch Count Number of markings since the current Job was loaded Total Count Number of markings over the life of the controller Selecting this area opens the performance page showing additional statistical information on the laser system throughput Print Position Allows the user to adjust the marking position scale rota
153. r a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10511 No SP program available The file smartspX sp is missing on the MMC MultiMediaCard Check the contents of the MMC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10512 AllprintBasic Protocol configuration error The AllprintBasic command string in the AOS database Config Input contains a configuration error for the serial protocol Modify the protocol settings on the PC with AllprintBasic and import again via SmartGraph into the AOS database Then reboot the ACC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10513 AllprintBasic Configuration error of the serial interface The AllprintBasic command string the AOS database Config Input contains a configuration error for the serial interface Modify the interface parameters on the PC with AllprintBasic and import again via SmartGraph into the AOS database Then reboot the ACC This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Control
154. r are attached G SHUTDOWN X 9 Line Speed Measure Line Speed Measure Line Speed 1 Ensure that the line is moving at constant speed during measurement and entry of line speed 2 Press Next to enter the measured speed in m min or Cancel to quit Cancel Next gt Table 5 5 Line Speed Page parameters Continued 5 18 Line Setup Rev AC CLARITY Laser Controller System Manual Parameter Description Configure Manually Allows the user to enter the Pulses per Revolution and the Distance per Revolution values manually Note This should be done by trained service engineers only A SHUTDOWN X 9 Speed Configure Manually Pulses Per Revolution 2000 gt Distance Per Revolution 170 000mm gt Ke Table 5 5 Line Speed Page parameters Continued Trigger Settings This option specifies how the product is detected and depends upon whether the products are moving past the laser on a conveyor or are placed as stationary objects manually The availability of the individual trigger settings depends on the selected trigger type and the product movement SHUTDOWN Ki Printhead Line Setup Trigger Settings 4 9 Start Delay 0 000ms 3 Blocking 10 000ms gt Trigger Mode External Falling gt Figure 5 11 Trigger Settings Rev AC Line Setup 5 19 CLARITY Laser Controller System Manual
155. rameter set to the database the error message will no longer appear When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10302 Shutter does not stay open Defective beam shutter Improper galvo FM board operation Exchange beam shutter Check galvo FM board operation This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10303 Shutter does not stay closed Defective beam shutter Improper galvo FM board operation Exchange beam shutter Check galvo FM board operation This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10304 Marking process interrupted by interlock Interlock has been opened Close the interlock to continue When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10305 Key switch has been opened while marking Keyswitch has been opened Close the keyswitch to continue When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10401 Template invalid The template selected for marking is defective or does not exist Check tem
156. rected using Clarisoft The EAN13 barcode contains a price that is too large to be encoded within the barcode Use Clarisoft to check and correct the maximum price value for price field that is referenced by the barcode Press the Clear button below to clear this warning message E1236 Invalid Job File Invalid Font The Job file contains a bitmap font field that is not supported by this printer Use Clarisoft to remove all bitmap font fields in the job Then download the corrected file to the printer Press the Clear button below to clear this warning message E1237 Invalid Job File Invalid Font The Job file refers to a missing or invalid bitmap font file Use Clarisoft to check and ensure that all text fields used by this Job file display properly in Clarisoft Then download the corrected file to the printer Press the Clear button below to clear this warning message Table 8 4 Error Messages and Warnings 8 12 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E1238 Invalid Job File Invalid Global Count Value The Job file uses a global counter that is not compatible with the current global count value The current global count value is either too long for the counter specified in the job or contains characters that are not valid The global count value will be reset when this job is selected Use CLARi
157. rectly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E39009 RF driver VSWR error Defective cable between RF driver and Q switch Defective cable between RF driver and LPC RF power supply is defective Check wiring Exchange RF driver This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E39012 Power supply General error An internal monitoring function of the power supply has detected an error Alltec DN A power supply Short circuit during operation Check power supply and exchange if necessary This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E55000 Defective customer interface Cl The arrangement of the bus terminals has been changed The hardware configuration of the CI has been changed Beckhoff error Check the bus terminals of the customer interface When the fault is corrected a Clear button will appear below Clear this fault and resume operation Table 8 4 Error Messages and Warnings Rev AC CLARITY Error Messages and Warnings 8 41 CLARiTY Laser
158. rint Production Audit Log The production audit log shows the log of machine changes and user changes made Note Production Audit Log is turned off by default and needs to be activated in Clarity Configuration Manager The logging mode can be set to None Normal or Advanced In Normal logging mode the log entries are deleted if there are over 500 log entries and older than 90 days In Advanced logging mode entries must be archived to a USB stick before logs will be deleted Figure 6 21 shows the audit log for both machine events and user events The user can also filter results to show either user events only or machine events only see Table 6 6 FE X Diagnostics Control Production Audit Log 4 Ge Parameters downloaded 13 47 00 2541 2013 5 CLARITY started 13 44 36 25 11 2013 gt n CLARITY exited 13 42 27 25 11 2013 gt Q amp CLARITY Update started Eid gt 5 Parameters downloaded 13 34 24 25 11 2013 gt a Parameters downloaded 13 34 18 25 11 2013 Parameters downloaded 13 33 57 25 11 2013 D DS Figure 6 21 Production Audit Log 6 30 Production Audit Log Rev AC CLARITY Laser Controller System Manual Button Function Lists both machine and user events Lists only user events amp LE j Lists only machine events 9 2 Table 6 6 Buttons to Filter the Log
159. rmation about the parts of controller This information is useful for ordering the spare parts for the controller Standard Controller Assembly Figure 9 1 Standard Controller Assembly Rev AC Standard Controller Assembly 9 1 CLARITY Laser Controller System Manual Figure 9 2 Yoke Assembly Item Number P N Description Qty A 406058 Controller 1 1 Bottom Case 1 Screw 2 3 405208 CLARITY LCD 8 4 Display and 1 Touch Screen 4 Screw 2 5 Top Case 1 6 Screw 6 7 406124 Control PCB 1 404457 Yoke assembly 8 Screw 2 9 Tube Mounting Bracket 1 10 Yoke Bracket 1 11 Handwheel 2 12 Washer 2 13 406377 Spare Memory Card 1 14 402797 CLARITY LCD Cable 8 4 1 15 406373 Spare Mains Switch Assembly 1 Table 9 1 Controller 9 2 Standard Controller Assembly Rev AC CLARITY Laser Controller System Manual Item Number P N Description Qty 16 406123 Power Supply Unit 1 17 Mains Lead 3 See Table 9 2 for part numbers of different languages 18 216030 Fuse Kit Set of 10 Table 9 1 Controller Continued tem is not shown in the figure Part Number Description 704432 IEC Mains Lead US Canada 704434 IEC Mains Lead Europe 704435 Mains Lead Japan 704436 IEC Mains Lead Italy 704437 IEC Mains Lead China 704438 IEC Mains Lead India South Africa 704439
160. rovided for the Screen 1 Yes print job TCPIP BinaryCom 3001 0 256000 msNetwork Port DefaultGate 0 15 way IPAddress 0 0 0 0 7 15 SubnetMask 255 255 255 0 7 15 TextCommuni JobSelection 0 Normal 1 cations Mode 1 Selection per print NetworkPort 0 0 256000 TextCommsAsync 0 0 214783647 Notifications Enabled TextComms ZipherASCIl 0 200 ParameterFile CommsProto col xml Table C 1 CLARITY Configuration Manager Continued Rev AC CLARITY Laser Controller System Manual Menu Options Value Max Comments USB PromptOn 0 No 1 Select yes to prompt if printer CLARiT YData i detects a CLARITY Data file on FileDetect 1 Yes the usb PromptOn 0 No 1 Select yes to prompt if printer CLARITYPa detects a CLARITY archive file rameterArchiv 1 Yes on the usb eDetect PromptOn 0 No 1 Select yes to prompt if printer CLARITYPrint 7 detects a CLARITY printer clone erCloneDetect 1 Yes file on the usb PromptOn 0 No 1 Select yes to prompt if printer CLARiTYUp detects CLARITY software dateDetect 1 Yes update file on the usb User CLARITY Language English 100 Select required language Interfaces a Measuremen 0 Metric 1 Select units inches or mm tUnits 1 Imperial Passwords Enable 0 Disable 2 Select the preferred password Passwords level 1 Normal 2 Advanced Recalibrate Touchscreen TouchToEdit Enabled 0 Disable 1 1
161. rror Hardware must be checked Contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00212 Wrong LIC detected Contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00213 Wrong HIC detected Contact your local service representative or support team who will be able to provide assistance E09000 Marking head Temperature of FM MHI assembly group too high The temperature of the FM or MHI board has exceeded the maximum value Improve cooling of the marking head clean cooling fins if necessary Ensure the air vents are clean Increase distance between markings if possible Check internal fan operation This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E09001 Marking head Supply voltage too low The supply voltage of the marking head is too low 16
162. rs a i a i amp Consumables Jobs Devices a gueg amp Operations Log Files amp s Sm C3 Script Files E ST mi Bl Database Location 0 Local 1 EnableUserTestPrint 1 Yes 1 Job Selection Mode D Product Code 1 G Logging Gi PowerSaving amp SATO Bl ShowJobDescriptiononHomeScreen 0 No 1 amp TCPIP P TextCommsAsyncNotificationsEnabled 0 0 2147483647 TexiCommsParameterFile ZipherASClICommsProtoc 0 200 amp Userlnterfaces J Connection open but not active Connection active Not connected Connection open but not active Connection active New Coder 1 Not connected Connection open but not active 3001 Connection active D MN Figure 6 25 Power Saving Modes CLARITY Power Saving 6 35 CLARITY Laser Controller System Manual Power Saving Mode z 0 None User interface will not dim when power is applied Power Saving Mode z 1 Minimal User interface will dim after 1 minute of inactivity Activity User touching the screen USB keyboard input Raising of an warning e g the moment the printer transitions from No Error into Warning Presence of an error Power Saving Mode 2 High User interface dims after 1 minute of inactivity User interface turns off after a further 14 minutes of inactivity Activi
163. s lt AG gt lt AH gt lt A 4096 Al Month Codes lt JA gt lt FE gt 512 lt MR gt lt AL gt MA Week Of Year lt 1 gt lt 2 gt lt 3 gt 4096 Codes lt 4 gt lt 5 gt Year of lt A gt lt B gt lt C gt 512 Decade Codes lt D gt lt E gt Line Selection EnableLine 0 No 1 Selection 1 Yes LineSelection 0 Communica 2 Mode tions 1 Binary Inputs 2 Binary Hot Bit Inputs Number of 4 16 No of lines Lines Table C 1 CLARITY Configuration Manager Continued Rev AC CLARITY Laser Controller System Manual Menu Options Value Min Unit Comments PrintHeadMapping Printhead1 Draft 12 1 1 4 Printhead2 1 1 4 Printhead3 3 1 4 Printhead4 4 1 4 Printer Codes Equipment 1 0 255 Reference Factory 1 0 255 Reference Reference ResetPrintLimitOn 0 No 1 Startup 1 Yes Shift Codes Number Of 0 0 168 Number Set up shift requirement Shifts Start Of Day 00 00 00 23 59 59 23 59 59 Start Of Hour Of 00 00 00 167 00 00 167 00 00 Week TimerCode ABCDEFGHIJ 10 10 Encryption Update Queue MaxQueue 1 1 20 Number Length System ComPort1 BaudRate 0 110 12 Baud rate selection 1 300 2 600 3 1200 4 2400 5 4800 6 9600 7 14400 8 19200 9 38400 10 56000 11 57600 Table C 1 CLARITY Configuration Manager Cont
164. s not close The beam shutter got jammed or is not identified Improper galvo FM board operation Check the beam shutter Check the shutter cable Check the plug in connections on the board Check galvo FM board operation This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10409 System error during preparation of marking Internal error during preparation of marking Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10410 The parameter set of the active template has been adjusted to the system The parameter set of the active template contains inadmissible settings for the laser The application database possibly belongs to a different laser system When the database has been saved this message will no longer appear Possibly the settings of the concerned parameter set have to be modified manually When the fault is corrected a Clear button will appear below Clear this fault and resume operation E10411 External text Value can only be marked once For an external text the property Prompt Once warning has been set and it has been tried to mark the external text with the same value twice Change the conte
165. ser System is not available due to a fault identified as a laser system fault Laser System Downtime Laser System Total time in a fault state Operational Availability This is a broader measure to reflect the full impact of the down time to production line Operational Availability tracks the downtime related to faults that might be classed as Procedural such as No encoder connected No template list selected The marking head is not connected The impact may be due to laser system issues operator related issues shift changeovers and so on Operational Availability is defined as Operation Downtime Operational Availability 1 Production Time The Production Time Proxy allows the availability calculation to change between customer selected operating modes running or laser system on The production time is defined based on the production time proxy chosen Running If both laser system and laser are switched ON Power On If the laser system is switched ON irrespective of the status of the laser If the laser system is powered down when a fault is active the amount of time that the laser system is off is also included in the production time Production Time Running Running time Power Off time in fault state Where Availability 6 3 CLARiTY Laser Controller System Manual 6 4 Availability Running time is the time when Laser is ON or requested to be turned ON Production Time Power ON
166. stem touch the software keyswitch button e 9 to toggle to disable position or open the manual keyswitch on the laser system The status bar changes to SHUTDOWN Viewing the Current Job or Image The name of the current job is displayed on the CLARiTY home page see Figure 5 3 on page 5 3 Before starting the production line make sure that the current job is the job that you want to mark To view more details of the current job proceed as follows 1 2 3 Rev AC Touch the name of the job on the home page This will display a preview of the job To magnify the image on the screen double touch on the image to zoom in and zoom out If you are satisfied that the job is displayed correctly you can start marking as described in Print Position on page 5 4 If the current job is not the job that you want to mark refer to the instructions in Selecting a Job for Marking on page 5 3 Touch the Back button on the navigation bar or the Home button to return to the home page Stopping the Marking 5 25 CLARiTY Laser Controller System Manual Downloading a Job File A job file can be downloaded from the PC to the laser system using the following methods Direct cable connection serial port of TCP IP USB memory stick Download Job File using TCP IP or Serial Connection 1 Connect the communications cable serial or ethernet between the PC and the corresponding port of the laser system Note
167. sword protection for some functions to prevent any access that is not authorised Abbreviations and Acronyms Abbreviation Expansion AC Alternating Current AOS Advanced Operating System ASP Analog Signal Processor FPGA Field Programmable Gate Array LED Light Emitting Diode UI User Interface WYSIWYG What You See Is What You Get Table 1 2 Abbreviations and Acronyms 1 4 Abbreviations and Acronyms Rev AC CLARITY Laser Controller System Manual Chapters in the Manual This manual is divided into twelve chapters An introduction to the topics that each chapter covers is shown in Table 1 3 Chapter Chapter Name Description No 1 Introduction Contains the information about this manual the main parts the related publications and writing styles used in this manual 2 Safety Contains the safety and hazard information 3 Installation Contains the information about complete laser system controller connections interconnecting cable and system setup 4 CLARITY Contains the information about CLARITY operating system and Operating System updating CLARITY operating system 5 Controller Contains the information about starting and stopping the Operation controller viewing and selecting a job for marking line setup modifying and deleting a job from the jobs database 6 Additional Contains the information about availability touch to edit quick Controller positi
168. system to ON position Laser Messages are in CIFF format Existing laser messages can be converted to CLARITY CIFF files using the CIFF converter See the CIFF Converter Instruction P N 468427 01 for additional information Rev AC How to Connect the Laser Marking System to the CLARITY Laser Controller 3 5 CLARiTY Laser Controller System Manual Startup Sequence 1 2 3 6 How to Setup the System Switch ON the power supply to the controller Start the controller For information on starting the controller refer Starting the Controller on page 5 2 Log into the UI at Level 2 Touch the Tools icon and touch Setup menu Select Level 2 and enter the password For information of passwords refer How to Set the Passwords on page 4 19 Navigate to Tools gt Setup gt Control gt Internationalisation and select the appropriate Language and Region Country a SHUTDOWN X miTools Setup Control 4 9 1 CLARITY Parameter Archives A Set Screen Orientation Degrees gt Internationalisation gt Recalibrate Touchscreen gt Date And Time gt Communications gt Contact Information gt lt gt v Figure 3 3 Control Page Once both Language and Region Country are set up confirm that the Measurement Units are as required If required setup screen orientation Switch on the laser system and start the laser system as described in the Laser System Manual Retain the Manual Keyswitch in op
169. t from a list of available updates Update files must be saved in clarityupdate folder on the root of the USB memory stick to be recognized Note Only present when a USB memory stick containing update files is inserted Table 4 5 Control Page Rev AC Using the Tools Page 4 7 CLARiTY Laser Controller System Manual Buttons Description Set Screen Orientation Allows the user to change the screen orientation by selecting 0 or 180 degrees as required 1 SetupsControl Set Screen Orientation 180 Degrees Cancel OK Internationalisation Allows the user to set the language of the CLARITY screen the international region country which control the date time formats and measurement units displayed within CLARITY Recalibrate Touchscreen Allows the user to recalibrate the touchscreen if touching the screen does not accurately locate the correct CLARITY button or Icon The laser system requests the user to touch several crosses which are displayed on the screen one after the other The screen is recalibrated when the automated process is complete Note If the calibration of the machine has too many errors and does not allow a user to navigate to this screen via the CLARITY panel the same functionality can be triggered from within CLARITY Configuration manager Date and Time Allows the user to set the system date and time of the laser system Communications Allows the user
170. that all Ethernet communication cables are shielded STP Cat5 Placement of the Controller A Warning PERSONAL INJURY Do not place the controller in a hazardous location Hazardous locations might cause an explosion leading to personal injury You must ensure compliance with all local regulations regarding equipment placement in potentially hazardous locations 2 4 Placement of the Controller Rev AC CLARITY Laser Controller System Manual Medical Emergencies This section provides important medical information in case of an accident N Warning PERSONAL INJURY In the event of a medical emergency contact a physician immediately Rev AC Medical Emergencies 2 5 Installation This chapter contains the following topics Unpack and Inspect the Laser System and the Controller The Complete Laser System CLARITY Laser Controller Connections How to Connect the Laser Marking System to the CLARITY Laser Controller OMark Version 8 5 3 2 1 or later required How to Setup the System Unpack and Inspect the Laser System and the Controller Note For information on unpacking the laser system refer Laser System Manual 1 Open the shipping box and make sure that all the parts listed in the packing list are present in the box If any part is missing contact Videojet Technologies Inc Refer to Chapter Support and Training for Videojet contact information Refer to Chapter Illustrated Parts List for
171. the translated versions of this manual For more information contact the Videojet distributor or subsidiary Rev AC About the Manual 1 1 CLARiTY Laser Controller System Manual Code Language 01 English US 02 French 03 German 04 Spanish 05 Portuguese Brazilian 06 Japanese 07 Russian 08 Italian 09 Dutch 10 Chinese Simplified 11 Arabic 12 Korean 13 Thai 15 Norwegian 16 Finnish 17 Swedish 18 Danish 19 Greek 20 Hebrew 21 English UK 23 Polish 24 Turkish 25 Czech 26 Hungarian 33 Vietnamese 34 Bulgarian 36 Chinese Traditional 55 Romanian 57 Serbian Table 1 1 List of Language Codes 1 2 Related Publications Rev AC CLARITY Laser Controller System Manual Content Presentation This System Manual contains different types of information like safety guidelines additional notes user interface UT terminology and so on To help you identify the different types of information different writing styles are used in this manual Positional References Positions and directions like left right front rear to the right and to the left are with respect to the controller when you see it from the front Units of Measurement This manual uses metric units of measurement The equivalent English measures are included in parenthesis For example 240 mm 9 44 inches Safety Information Specif
172. this fault message E1012 No Line Selected A print signal has been received for a product without any line selection Please check that the line selection system is functioning correctly Press the Clear button below to clear this fault message E1013 BETA Expired The beta period for the release has expired Contact your maintenance engineer or local service representative to correct this problem E1014 Time and Date may be incorrect The printers time and date may not be correct The most common cause for this is that the battery used to backup the printers clock is flat If this problem returns the next time the printer is power on then the battery should be replaced If the battery is flat the date and time the currently selected job and some performance data will be lost when the printer is switched off Press the Clear button below to clear this warning message E1100 Invalid Job File bad field reference The Job file is invalid and needs to be corrected using Clarisoft There is a circular reference between fields in the Job file Use Clarisoft to check and correct the relationships between fields in this Job file Then download the corrected file Press the Clear button below to clear this fault message E1101 Invalid Job File missing data source field The Job file is invalid and needs to be corrected using Clarisoft A field in the Job file refers to another field for its sour
173. tion The policy of Videojet Technologies Inc is to manufacture non contact coding systems that meet high standards of performance and reliability Therefore we employ strict quality control techniques to eliminate the potential for defects and hazards in our products The safety guidelines provided in this chapter are intended to educate the operator on all safety issues so that the operator can operate the laser system safely Equipment Safety Guidelines This section contains important safety guidelines pertaining to the operation and handling of the controller and associated equipment N Warning PERSONAL INJURY While performing maintenance or repair work disconnect the mains supply unless it is absolutely necessary to leave the supply on while carrying out adjustments Comply with Electrical Codes N Warning PERSONAL INJURY electrical wiring and connections must comply with applicable local codes Consult the appropriate regulatory agency for further information Electrical Power N Warning PERSONAL INJURY This equipment must be installed with a locally positioned mains supply isolation device This can be either a plug and socket or a switch connector or circuit breaker in accordance with IEC 60947 3 or IEC 60947 2 2 2 Introduction Rev AC CLARITY Laser Controller System Manual A Warning PERSONAL INJURY Ensure that all external energy sources mains and mains power connector are isolated from equipm
174. tion or mark sets for the current job If available allows the user to select pilot laser Control Buttons Allows the user to perform the following actions Keyswitch enable disable software keyswitch only Disable Stop the marking mode Enable Run the marking mode Keyswitch for more information refer Table 4 2 on page 4 4 Stop Run mark Home Button Allows the user to access the Home screen as shown in Figure 4 1 on page 4 2 Job Select Button Allows the user to select the required job from the list by opening the job select page Table 4 1 Home Screen Buttons Continued Rev AC Using the Home Page 4 3 CLARITY Laser Controller System Manual Icon Description Manual keyswitch closed Manual keyswitch opened Software keyswitch disabled Software keyswitch enabled A WE Table 4 2 Keyswitch Icons Using the Tools Page Touch the Tools icon on the home page to access the tools page see Figure 4 2 A OFFENE X Tools 4 E Setup Diagnostics NN Databases lt Ka Figure 4 2 Tools Page 4 4 Using the Tools Page Rev AC AC CLARITY Laser Controller System Manual Buttons Description Setup Page Permits the user to modify a small subset of the laser system setup parameters Diagnostics Page Provides on line fault fin
175. to reset all communication ports to factory default settings if corrupted These default settings configure the laser system to communicate with CLARISOFT and CLARITY Configuration Manager Contact Information Allows the user to enter the laser system location address Table 4 5 Control Page Continued Working with the Option Setup Page Navigate to Tools gt Setup gt Option Note Options page is not available for Laser controller 4 8 Using the Tools Page Rev AC CLARITY Laser Controller System Manual Working with Diagnostics Navigate to Tools gt Diagnostics see Figure 4 6 as Tools Diagnostics Om Printhead Consumables Control Options lt _ gt 4 gt a Ki d Figure 4 6 Diagnostics Page The diagnostics page allows you to access the following pages e Printhead Consumables Control for example software versions system information communications port status Options Note Consumables and Options are not available for Laser controller Rev AC Using the Tools Page 4 9 CLARITY Laser Controller System Manual Working with Printhead Diagnostics Navigate to Tools gt Diagnostics gt Printhead see Figure 4 7 aj Tools Diagnostics Printhead e Product Counter Print Counter 3 Global Print Counter 191 Marking Time 23 114ms Line Speed Om min Event Log gt Inputs A y Relative Operating Hours
176. ty User touching the screen USB keyboard input Printing Raising of a warning e g the moment the printer transitions from No Error into Warning Presence of an error 6 36 CLARiTY Power Saving Rev AC AC CLARiTY Laser Controller System Manual Power Saving Mode z 3 Full User interface dims after 1 minute of inactivity User interface turns off after a further 14 minutes of inactivity Activity User touching the screen USB keyboard input Raising of a warning e g the moment the printer transitions from No Error into Warning Presence of an error Note When an error is present the screen will be at full brightness Note When a warning occurs the printer treats it as an activity event and will dim and switch off after 15 minutes if the warning is ignored Note In High power saving mode printing is treated as an activity event CLARITY Power Saving 6 37 Maintenance This chapter contains the following topics Replacement instructions nformation on care Maintaining the power supply Maintaining the controller and laser system N Warning PERSONAL INJURY Before attempting any maintenance or repair on laser system and its environment the laser system must be disconnected from the power supply Replacement Instructions Rev AC When you order a spare part kit the replacement instructions of the respective spare part are provided along with the kit For more
177. ult oc 12 14 32 25 11 2013 On LaserCounter1b JOB 6 Performance Throughput Op m Batch Count 2 A lt gt Total Count 121 Figure 8 1 Fault Display Several faults and warnings may occur at the same time Faults will always be displayed first To view the faults warnings in more detail and to view instructions on what to do about them touch the red or yellow area in the status window at the top of the CLARITY display 6 2 Fault Messages and Warnings Rev AC AC CLARITY Laser Controller System Manual Clearing a Fault Message or Warning The instructions in this section provides information on how to clear a fault message A similar procedure is used to clear warnings To view the details of the fault list proceed as follows 1 Touch the red FAULT message on the status bar to view the list of faults see Figure 8 2 Faults FAULT E6251 n Interlock Open lt gt v Figure 8 2 Fault Selection 2 Touch the fault name in the list 3 The details of the fault is displayed Follow the on screen instruction for correcting the fault aults FAULT E6251 c e Laser Interlock Open FAULT E6251 The safety interlock for the laser marking head has been opened Ensure that the laser marking head can be operated safely and close the interlock This fault can then be cleared A lt gt i Clear Figure 8 3 Fault Details Dis
178. use only Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation 00008 Debug use only Contact your local service representative or support team who will be able to provide assistance When the fault is corrected a Clear button will appear below Clear this fault and resume operation E00100 Critical error SP Fatal internal error A not initialized interrupt has been called or similar Contact your local service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00101 Stack error SP Fatal internal error Stack overflow Contact your local Service representative or support team who will be able to provide assistance This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E00102 SP received unknown command from AOS Internal communication error on the ACC In most cases this error indicates a version conflict Check your Qmark version and use a new MMC if necessary When the fault
179. valid and needs to be corrected using Clarisoft An EAN barcode in the Job file contains more than 48 characters which is the maximum length for this type of barcode Use Clarisoft to check and correct the EAN barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1203 Invalid Job File EAN barcode out of specification The Job file is invalid and needs to be corrected using Clarisoft The field for an EAN128 barcode does not contain enough data to form a valid Application Identifier Use Clarisoft to check and correct the EAN128 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message E1204 Invalid Job File EAN barcode out of specification The Job file is invalid and needs to be corrected using Clarisoft An EAN128 barcode field contains an application identifier containing non numeric data but EAN128 application identifiers must be numeric Use Clarisoft to check and correct the EAN128 barcode fields in the Job file Then download the corrected file Press the Clear button below to clear this fault message Table 8 4 Error Messages and Warnings 8 8 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E1205 Invalid Job File EAN barcode out of specification The Jo
180. with Canadian regulations regarding safety by T V S D America For Customers in the European Union This equipment displays the CE mark to indicate conformance to the following legislation EU Electromagnetic Compatibility Directive 2004 108 EC CISPR22 Class A Radio disturbance characteristics Limits and methods of measurement for IT equipment CISPR24 Immunity characteristics Limits and methods of measurement for IT equipment EN 61000 3 2 Limits for harmonic current emissions equipment input current up to and including 16A per phase EN 61000 3 3 Limitations of voltage fluctuation and flicker in low voltage supply systems for equipment and rated currents up to and including 16A per phase EC Low Voltage Directive 2006 95 EC Essential health and safety requirements relating to electrical equipment designed for use within certain voltage limits EN 60950 1 Safety requirements for information technology equipment including electrical business equipment ii Rev AC CLARiTY Laser Controller System Manual Support and Training Rev AC Contact Information If you have any questions or need assistance contact Videojet Technologies Inc at 1 800 843 3610 for all customers within the United States Outside the U S customers should contact their Videojet Technologies Inc distributor or subsidiary for assistance Videojet Technologies Inc 1500 Mittel Boulevard Wood Dale IL 60191 1073 U S A Phone 1 800 843
181. ystem After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation Table 8 4 Error Messages and Warnings 8 34 CLARITY Error Messages and Warnings Rev AC CLARiTY Laser Controller System Manual Error No Report on CLARITY Operator Interface E10901 A CAN node has carried out an inadmissible reset The CAN bus node is defective Defective wiring Check the CAN bus node Check wiring of CAN bus This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10902 Lost connection to a CAN node The CAN bus node is defective Defective wiring Check the CAN bus node Check wiring of CAN bus This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10903 A CAN node cannot be initialized The CAN bus node is defective Defective wiring Check the CAN bus node Check wiring of CAN bus This fault cannot be cleared directly Turn off the Laser Controller and the laser marking system After a short interval turn on the Laser Controller and the laser marking system and confirm normal operation E10904 The customer interface Cl is not supplied with 24 V

Download Pdf Manuals