1. technology BSD BSD Plus APPLICATION NOTE How to create a Web Scada Presentation CRE Technology believes that all information provided herein is correct and reliable and reserves the right to update at any time CRE Technology does not assume any responsibility for its use E amp OE CRE Technology 130 All e Charles Victor Naudin Zone des Templiers Sophia Antipolis 06410 BIOT FRANCE Phone 33 0 4 92 38 86 82 Fax 33 0 4 92 38 86 83 www cretechnology com info cretechnology com SARL au Capital de 300 000 Euros RCS Antibes 7488 625 000 15 N TVA FR54 488 625 583 ee e Decemberr 12th 2009 First version created You can download this documentation and the different documentation relating to the BSD BSD Plus on our web site http www cretechnology com NOTE Read this entire manual and all other publications pertaining to the work to be performed before installing operating or servicing this equipment Apply all plant and safety instructions and precautions Failure to follow instructions can cause personal injury and or property damage Contact your CRE distributor for course training Trademarks All trademarks or registered marks in this manual belong to their respective manufacturers TCP Transmission Control Protocol is a set of rules used along with the Internet Protocol IP to send data in the form of message units between computers over the Internet Hyper Text Transfer H
2. Administrator Logout Select page Ea Status Devices Alarm Log Configuration Setup About Templates Devices Pages Alarm Log Bindings Edit parameter 2 Genset 1 Device Genset 1 Group Gensys Parameter General Total Power kt Description General Total Power kW Presentation format Default Presentation scaling ro Copyright CRE Technology Select the device from where the data parameter should be read Select the group where the data parameter is to be found Select the parameter Enter a name for the point or copy using down arrow at end of parameter row Select how data should be presented O oa A WO N Click save settings A61Zx_en_How to create a Web Scada Presentation 11 14 Repeat the steps above and create as many parameters as preferred for presentation on the page Below is a picture that shows what it would look like when we have configured some more parameters for presentation on the page PH Configuration Left Overview Descnpton Device Parameter General Total Power kW Gensetz General Total Power kW edit delete delete delete delete delete delete delete delete delete edit Generator Frequency Hz Genset 2 Generator Frequency Hz edit 4uto Manual Genset 2 Auto Manual edit edit Generator Global Power k VAR Genset 2 Generator Global Power k VAR edit Generator Global PH cos phil Genset 2 Generator Global PH cos phil edit AN a A M o ola Bu
3. There is also a field labelled Advanced Overview This page has restricted access and can only be accessed when logged in as admin or super admin Further details regarding the functionality of the Advanced Overview page is described in the user manual of the BSD BSD Plus If the Advanced Overview page will be used to present data a name is also set here CRE Technology BSD plus Logged in as Administrator Logout Select page ea Status Devices Alarm Log Configuration Setup About Templates Devices Pages Alarm Log Bindings LH General Page configuration Picture 62 763 kbyte used Page Name i Genset i _ as delete _ Overview name Electrical meters The picture can not be wider then 37 0px larger then 50k and it needs to be in gif png or jpg format Advanced overview name Engine state Configuration Left Overview Description Device Parameter 1 General Total Power kW Gensel 1 General Total Power kW Cedit delete 2 Ledit delete 3 edit delete 4 jm 1 Assign a name to the page 2 Set a name to describe the data viewed on the page 3 Click save settings A61Zx_en_How to create a Web Scada Presentation 9 14 When the name of the page has been set press the save settings button to store the information in the BSD BSD Plus unit The page that presents data can also show a picture describing the installation or the equipment containing the data To store a pictu
4. containing the data is properly connected to the BSD BSD Plus and the serial communication properly configured the data values for each configured parameter shall show in the data tables as shown in the picture below CRE Technology Select page ea Status Devices Alarm Log Configuration Setup About Electrical meters Engine state Description Value Description Value General Total Power kw R Generator Output Voltage U13 Generator Output Voltage U32 Generator Frequency Hz Generator Output Voltage U21 Vv Auto Manual pS Generator Current I1 A Generator Current 12 A Generator Global Power kVAR Generator Current 13 A Generator Global PH cas phi Generator Power Pi kw Generator Power P2 kw Bus frequency Generator Power P3 kW Battery Voltage Vv e Copyright CRE Technology A61Zx_en_How to create a Web Scada Presentation 13 14 9 References m OO O O e O BSD BSD Plus Technical Doc CRE Technology 1 2 BSD BSD Plus Quick Start Guide CRE Technology 1 0 How to create a device template CRE Technology 1 0 A61Zx_en_How to create a Web Scada Presentation 14 14
5. Configuration Setup About Templates Devices Pages Alarm Log Bindings Name Genset 1 Template Gensys2 0 Modbus TEP server IP address Modbus TOP server port Modbus Slave Address none Ol Gensys2 0 0 0 set J clear eae Copyright CRE Technology 1 Assign a name to the device 2 Select device template 3 Set the Modbus address 4 Click save settings The device shall now have been added to the Device Configuration list A61Zx_en_How to create a Web Scada Presentation 8 14 7 Configuring the page for presenting data values To present equipment data on a page through a web browser we need to configure which data shall be presented To do this start with selecting Pages in the menu Press the button called add page to add a page CRE Technology BSD plus Logged in as Administrator Logout Select page a Status Devices Alarm Log Configuration Setup About Templates Devices Pages Alarm Log Bindings 51 Page Configuration Descripton Genset 1 Unigen Backup Genset Genset 2 Global view clear start pane g Copyright CRE Technology 1 Click Pages 2 Click add page Assign a name to the page in the edit field labelled Page Name This is the name that will appear as the title of the browser window Also assign a name that is describing the data presented on the page in the field labelled Overview Name This name will be presented in the menu of the page
6. TTP is a set of rules for exchanging files text graphic images sound HTTP i Protocol video and other multimedia files on the Web DHCP is a standard protocol that automates the process of configuring network hosts by allowing hosts to obtain IP addresses and configuration parameters CENA A device that makes it possible to transfer data between networks of y different kind e g Modbus RTU and Modbus TCP Describes a Modbus slave device as a collection of groups and Template parameters Device a A Modbus slave unit that is connected to the BSD Plus Table 1 Terminology Transmission Control TCP IP GP Protocol Internet Protocol DHCP Dynamic Host Configuration Protocol A61Zx_en_How to create a Web Scada Presentation 2 14 Table of contents 1 MAE OG UCUION wissetecacotnse sap aseecnsesicetutnaeatecnaatasesssnacaicceetai sine vensaanesessse sa nacsspessdessanecscunaeeuseeeieoseaeees 4 2 TOEN a A evans seeesvetareseccecedeusaresseuresuncsioortessarsteeceiseiansssessiasssesicacsueteess 4 3 GUNO SOOO E EAEE sae E N E EAA 5 4 Configuring serial settings sssesesesosososososososoeoeosoeoeoeoeoeoeseoeoeoeoeoeoeoeoeoesesesesesososososososososoeoeo 6 5 Install or create a device template s sosososoeosoecsceceoeoeoecececececesesececoecsececescsesesosososososoeosseoeo 7 6 Define the Device s connected to BSD BSD PIUS s 0ccccssccesscsscscsscccessccecsccscccessecessssecsssecese 7 7 Configuring the pag
7. and it needs to be in gif png or jpg format A default welcome page was presented when we started creating this configuration and accessed the web interface of the BSD BSD Plus unit after logging in It is possible to replace that welcome page with a page presenting data as the default page to be loaded after logging in To select the page that we are creating as the default start page press the set as start page button 8 Configure the data to be presented Once the edit button has been pressed a page will be shown where we can configure the parameter that we want to present in that data field Start by selecting the device where the parameter will be stored in the drop down menu at the top all configured devices will be available here Then select the parameter group the data value is stored in In A61Zx_en_How to create a Web Scada Presentation 10 14 the example below we are configuring a temperature value stored in the parameter group named Temperature Input In the description field it is possible to enter a name describing the data that will be shown and in our case we have a temperature value Assume the value represents the temperature of a boiler The description field makes it possible to enter an appropriate name that is easier for a user to relate to such as Boiler temperature The button with the arrow can also be used to copy the default name to the parameter description CRE Technology Logged in as
8. ble Seconds 52 IP Authentication Enable IP Number raz Copyright amp CRE Technology A61Zx_en_How to create a Web Scada Presentation 6 14 5 Install or create a device template The BSD BSD Plus uses device templates when a configuration is created A template stores information about available parameters within a device or a system This application note does not describe how to create a template but this is described in a separate document How to create a device template That application note is available for download at http www cretechnology com The first step in the configuration is to make sure we have a template installed in the BSD BSD Plus unit In the menu select Configuration and then Templates in the sub menu This brings up the configuration page for templates If no templates earlier have been installed in the unit the list of available templates will be empty To install an existing template from disk press the add template button or to create a new template follow the instructions in the application note mentioned above and then click the restore button for the new template This will bring up a dialog window which is used to browse to the template file CRE Technology BSD plus Select page Status Devices Alarm Log Configuration Setup About Templates Devices Pages Alarm Log Bindings Description Gaensyaz 0 UNTGEN MOX 11939 amp copyright CRE Technalouy To g
9. e for presenting data values c ccccceccececcecccceccsccccsccccecceccccecceccccescscescs 9 8 Configure the data to be DIeSOnteG veciscsccsissactucccsetunssscvansasesssvsadivsvecvidecassc aviacsssovsrdivenseisenstes 10 I RETENOS oirin EE A A EE ted A EA 14 A61Zx_en_How to create a Web Scada Presentation 3 14 1 Introduction This application note describes how to create a configuration to present live data values through the Web server in the BSD BSD Plus module The BSD BSD Plus module acts as a bridge from Modbus TCP to Modbus RTU making it possible for a Modbus TCP based controller to connect with Modbus RTU based devices The BSD BSD Plus is a device that is not only designed to provide the bridging function but to also handle alarm management data logging as well as providing a web based user interface for accessing data The web based user interface can be used to present data of the instrument or system the BSD BSD Plus is connected with This application note describes how to create such a configuration The BSD BSD Plus has been successfully configured for many applications and CRE publishes device templates for several devices Please contact CRE Technology for further information regarding available device templates 2 Equipment BSD BSD Plus Modbus version 3 0 or later Personal computer with a Web browser Modbus RTU compatible device including manual describing available Modbus registers Et
10. e to properly communicate To modify the serial settings in the BSD BSD Plus select Setup in the menu and select Modbus in the sub menu Select transmission mode RTU for Modbus RTU or ASCII for Modbus ASCII This needs to be selected according to the communication protocol used by the connected device The physical media can be selected to either RS 485 or RS 232 Make sure the selection corresponds to the physical media being used between the BSD BSD Plus and the connected equipment Also select the Baudrate Parity and Stop bit accordingly with what is preferred for the communication Make sure all devices are configured for the same settings If this is not the case communication will not work properly Once we are done press the save settings button at the bottom of the page to store the configuration CRE Technology BSD plus 4 Logout Select page Status Devices Alarm Log Configuration Setup About Users Modbus Modem Regional E Mail SNMP Webserver GPS Ethernet System CRETechnology com b Serial Settings Modbus RTWASCI Transmission Mode Slave Response Timeout Physical interface Baudrate Character Format Extra delay between messages Character delimiter Use function code 15 when writing single bits coils Use function code 16 when writing single registers l Ethernet Settings Modbus TCP Port Humber Gateway Register Enable Address Server Idle Timeout Ena
11. et templates just click this link New template name File name FS Click Configuration in the menu Select Templates in the sub menu Click add template Enter a name and click ok This name will be changed after restore To upload template from disk click restore O a A WB N Browse the template file and click restore In this application note we will be using a template file for a Modbus RTU based I O node called BSD BSD Plus I O Extender Once we have installed the template for this unit the page looks as the picture below 6 Define the Device s connected to BSD BSD Plus A61Zx_en_How to create a Web Scada Presentation 7 14 Next we need to define the device s that we have connected to the BSD BSD Plus Click Devices in the sub menu and then press add device at the bottom of the configuration page for devices CRE Technology BSD plus Status Devices Alarm Log Configuration Setup About Description Template Gersel 1 Senay s2 i0 Genet Backup Lip UNDE Genet 2 Gendys2 0 ea Copyright CRE Technology 1 Go to Devices 2 Click add device Assign a name to the device in the field at the top of the page and select the template that represents the device from the drop down list Also set the Modbus Slave address of the device in the edit field and press save settings CRE Technology Select page iw Status Devices Alarm Log
12. hernet network including connections between the BSD BSD Plus and the PC A61Zx_en_How to create a Web Scada Presentation 4 14 3 Getting started This application note assumes that the BSD BSD Plus module is properly installed and accessible over the Ethernet network interface If this is not the case please refer to the step by step installation of the BSD BSD Plus for further instructions which describes the required steps to install this properly and access the unit over an Ethernet network Open your web browser and enter the address path IP address of the module to connect to the BSD BSD Plus module Login as administrator default login and password are both admin by entering the correct user and password information When properly logged in the default welcome page will be shown to you as below in the picture if no earlier configuration has been done If there already is a configuration stored in the module a page presenting information corresponding to that configuration will be shown CRE Technology BSD plus Logged in as Administrator 4 Logout Select page Ea Status Devices Alarm Log Configuration Setup About Welcome fez Copyright CRE Technology A61Zx_en_How to create a Web Scada Presentation 5 14 4 Configuring serial settings The serial communication link between the BSD BSD Plus module and the equipment connected to it need to be configured for the same serial settings to be abl
13. re in the module it needs to be uploaded This is done by pressing the Browse button next to the name fields at the top of the page CRE Technology BSD plus Logged in as Administrator S Logout Select page a Status Devices Alarm Log Configuration Setup About Templates Devices Pages Alarm Log Bindings LH General Page configuration Picture 62 763 kbyte used Page Name Parcourir Genset i Cmmi Caleta J arisen Electrical meters The picture can not be wider then 37 0px larger then 50k and it needs to be in gif Png or jpg format Advanced overview name Engine state 2 Configuration Left Overview Description Device Parameter 2 edit delete 1 Click Browse to select a picture 2 Click upload to save the picture 3 Preview of the picture Pressing the browse button will open up a dialog window which makes it possible to locate a picture file on the local hard drive Select the file and press the Open button of the dialog window The path to the file will appear in the text field next to the Browse button after the Open button was pressed To store the picture in the BSD BSD Plus unit press the upload button as shown in the picture above A smaller preview of the picture will show in the rectangle to the left of the upload button when the picture has been stored in the BSD BSD Plus unit The picture can not be wider then 870px larger then 50k
14. s frequency Genset 2 Bus frequency edit Battery Voltage V Genset 2 Battery Voltage edit 10 Configuration Right Overview Descnpton Device Parameter 1i Generator Output Voltage U13 w Genset Generator Output Voltage U13 W edit delete delete delete delete delete delete delete delete delete Generator Output Voltage U32 W Genset 2 Generator Output Voltage U32 W Generator Output Voltage U21 Genset 2 Generator Output Voltage Uzi edit Generator Current li A Genset 2 Generator Current I1 A edit Generator Current I2 A Genset 2 Generator Current I2 A edit Generator Current I3 A Genset 2 Generator Current I3 A edit Generator Power Pi kW Genset 2 Generator PowerPi kW edit Generator Power P2 ki Genset 2 Generator Power P2 ki edit Generator Power PS ki Genset 2 Generator Power PS ki edit Descnpton Device Parameter 71 Dil Pressure Genset 2 Dil Pressure 22 M ater Tem perature Genset 2 W ater Temperature 23 14 Llawes wie ament Lessee ee i a E E au To view the page we have configured select the title name of the page that will be available from the drop down menu at the top left of the window as shown in the picture below Select the page and press the go button Select page Genset 1 Unigen Backup Genset Genset 2 Glabal view 1 Select the page in the drop down menu A61Zx_en_How to create a Web Scada Presentation 12 14 Now we are done If the device