Home

DUAL PUMP STARTER PANEL

image

Contents

1. USER MANUAL PROTON POWER CONTROL PVT LTD PUNE DUAL PUMP STARTER PANEL Product Code PSP 33M 000 FAULT RESET Features e Three digits 7 segment bright display for current Calibration using front keys User Programmable Password protected set parameters Inbuilt 3 Phase 10 A Contactor for load control e Message Display for faults The Starter Panel has is solid state Current Meters measures currents and provides protection against overload for both the motors This is based on a Microchip programmed for the application Meters supplied preprogrammed for operation and can be directly installed Specifications Nominal Input Current 0 9 A per Phase Accuracy Current 0 25 1 dgts Resolution Current 0 01 A Environmental 1 Working Temp 0 to 55 C 2 Storage Temp 10 to 70 C 3 Relative humidity 10 95 96 Non Condensing 4 Warm up time 10 Sec Enclosure 1 Mounting Panel mounting Cut Out Size 182 H X 92 W 105 W X 200 L X 193 H mm Screw ON Terminals 2 Enclosure 3 Terminal WORKING In normal running mode display shows r HP R phase Current y HP Y phase Current b HP B phase Current r Rp R phase Current y rP Y phase Current b rP B phase Current lt Faults if any gt oL HP Over load HP Ub HP Unbalance HP oL rP Over load rP Ub rP Unbalance rP SP HP Single phase HP SP rP Single phase rP
2. All the protections like Overload current unbalance are activated in Auto as well as manual mode Auto Manual selection is done from front switch In any mode if the faults are present controller immediately turns off the motor having the fault The motors can be restarted by resetting the fault by pressing the Decrement key In manual mode there are two separate switches one for each motor to turn on and off If the supply is within the range and there is no fault condition an ON timer starts decrementing to zero and motor relay is turned ON This relay interlocks with the Pump On signal After the Pump motor is switched on if any unhealthy condition occurs fault LED start blinking up to trip delay time and then the is Relay is turned OFF Fault LED continuously glows if the faulty condition persists NO oP ON LED Indications RED LED Motor 1 RWP and Motor2 HPP Over Load Current Unbalance and Single Phase Faults Green LED If auto Mode Green LED turns ON for manual mode Green LED is turned off And on LED display MAN is displayed e SET This key is used to change the controller from RUN mode to e FUNCTION mode for parameter setting e INC Up scroll the parameter amp USER MANUAL parameter value e DEC Down scroll the parameter amp parameter value For manual reset of Fault Note To Load default parameter Press INC key on power ON Front Switches 1 Auto Manual selec
3. CREMENT OR 55 1005 5 DECREMENT OR INCREMENT 5s 100s ENTER DELAY DEFAULT 5 YES DEFAULT 105 RWP MOTOR SET DECREMENT OR YES DISPLAY DECREMENT OR SET INCREMENT Y ES NO ENTER YES PASSWORD DECREMENT OR CHANGE INCREMENT 0 9999 DEFAULT 11 YES T O YES m
4. rameter value down to minimum limit 7 To save the settings value wait for five e seconds Note 1 Calibration setting is for Factory Setting only 2 For manual reset of faults press Decrement Key 3 Password 5 is applicable only When display current enable mode is disabled 4 To Load default parameter Press INC key on power ON Field Terminal Layout Back View AC SUPPLY 1PHASE HPP OUTPUT RWP OUTPUT 415V 50Hz HPP ew RWP OUTPUT TO HPP TO RWP MPV DOSING CONTACTOR CONTACTOR POWER PUMP USER MANUAL FLOWCHARTS IF FUNCTION KEY PRESSED PASSWORD DISPLAY HPP RWP CURRENT ENTER PASSWORD PASSWORD 11 YES DISPLAY SETTING PARAMETERS ENTER YES OLHP E DECREMENT OR DEFAULT 5A INCREMENT 2A 13A YES r SET we J OLRP DECREMENT OR DEFAULT 5A INCREMENT 2A 13A YES SET UBHP DEFAULT 40 DECREMENT OR INCREMENT 2026 5026 YES gt ens DECREMENT OR E o lo DEFAULT 40 NCREMENT 20 50 YES PROTON POWER CONTROL PVT LTD S NO 28 JAGTAP DAIRY PIMPLE NILAKH PUNE 411027 TEL 020 2727 0800 27276777 TEL FAX 020 2727 0100 MOBILE 9764885010 9422009655 E MAIL rdpawar protonpowercontrol com accounts protonpowercontrol com PROTON POWER CONTROL PVT LTD PUNE ENTER DECREMENT OR INCREMENT 1s 30s ENTER DECREMENT OR INCREMENT 1s 30s ENTER DE
5. tion switch 2 RWP Motor1 manual ON OFF control 3 HPP Motor 2 manual ON OFF control SETTINGS Sr Parameter Mi Max Default Unit No n 1 Over Load 2 0 13 0 5 0 Amp oLHP 2 Over Load 2 0 13 0 5 0 Amp oLrP 3 Unbalance 20 50 40 of Current Over ubHP Load 4 Unbalance 20 50 40 of Current Over ubrP Load 5 Over Load 1 30 5 sec trip Delay trp 6 Unbalance 1 30 5 sec Current trip Delay ub trp 7 HPP Motor 5 300 10 sec ON Delay HPon 8 RWP 5 300 10 Motor Delay HPon 9 HPP 3P 3P NA Single Thr ee Phase 10 RWP 3P Single Thr ee Phase 11 Display no yes yes NA Currents Enable dISP If disabled shows AUTO MAN selection PROTON POWER CONTROL PVT LTD PUNE SPP fault for the same is disabled for the motor which is selected as single phase Current displayed will be of the connected phase CONTROLLER FUNCTIONS Password is 11 for Overload setting 20 for rest parameter settings amp password 5 is for displaying currents for one cycle Procedure to change parameter settings 1 Press SET key 2 Enter Correct Password 3 Wait to check password 4 Using UP Arrow amp down Arrow key user can change setting parameters Press UP Arrow Key to increment parameter value up to maximum limit 6 Press down Arrow key to decrement pa