USER MANUAL BARRIER for printing - hi
Contents
1. USER S MANUAL AUTO BARRIER SYSTEM COPY RIGHTS 2009 MADE IN KOREA SAFETY INSTRUCTION Before to proceed to barrier installation please read this safety instruction manual carefully to avoid any damage or injury V V NN V Please check 1f all accessories such as control box boom and main body of barrier cabinet are free from any damage or physical defects During installation make sure the main power is shut off The cabinet body must be properly grounded We suggest using cable with minimum of 1 5mm2 or flat wires atleast gauge 16 Do not dismantle the original wiring or set up without proper noticed from the distributor If during power fail off please switch off the power supply first then open the cabinet and release the handle manually to open the barrier boom at top position Please install the release button at secure area to avoid any accident It should be installed out of reach of children Do not operate the remote control if you cannot see the status of barrier Please secure the wireless remote control to secured area or designated personnel only Please don t open the cabinet door if the barrier 15 at working state The users must installed safety devices such as loop vehicle detector or photocells to avoid accidents It is the responsibility of the clients since we insist the safety devices at the start The client must inform the users to not stay at barrier drop zone area and must designate prop
2. and 2 TECHNICAL DIEMENSIONS 348 X268 Max 6000mm NN CO rari 5 10 BALANCE SPRING ADJUSTMENT ADJUSTING THE BALANCE SPRING IMPORTANT The barrier is supplied al ready balanced for the exact beam length specified in the order Should a fine adjustment of the beam balance be needed proceed as follows 1 Rotate the Spanner thenopen the cover Fig 3 2 Adjustthe pre loading ring nut Fig 4 The beam is correctly balanced when it remains steady in the 0 and 90 positions If the beam tends to close turnthe ring nut clockwise fit tends to open turn the ring nut countclock wise 4 expand screws NUMBER OF BALANCE SPRING BOOM LENGTH NUMBER OF SPRING SPRING LENGTH AEA HN QUICK RELEASE FUNCTIONS During power failure and in the absent of UPS or back up power you need to switch off the main switch and release the lever manually up to TOP or vertical position then Lock it and once the power is back please switch on the main switch and the barrier boom automatically goes down at normal state Please see Fig 5 L EAS e pci E N Screw for horizontal Screw for vertical of boom of boom All limit switches motor and control unit are already connected and only photocell loop detector and power supply AC source are needed for the proper installation as shown below
3. er staying areas and proper distance from the barrier The client will provide UPS or AVR to stabilize the power supply source to avoid motor damage due to power fluctuation surges currents short circuit etc WIRELESS REMOTE CONTROL CODE SETTINGS Press Learn Button and the learn LED lights Press the button on the transmitter until the LEARN LED flash and off Coding is successful please try the coded remote control to test it Please program other transmitter based on above procedure WIRELESS REMOTE CONTROL CODE DELETING Press Learn Button and hold on until the LEARN LED light switch off gt Now deleting is successful WARRANTY The barrier is still under warranty if the following conditions are still intact The warranty void sticker is not damage or altered There is no sign of mis used tampered improper installation damage caused by fire power interruption surge current riot natural calamities and any acts of Nature gt Kindly inform us not later than 7 days from the date of purchased if found no watranty sticker attached during acceptance of the purchased item s Any claim outside that period is not covered and not entitled to any warranty parts amp Services gt For details you may contact the authorized agent distributor HI R Technology and Service Co DISTRIBUTOR INFORMATION HI R Technology and Service Co 2 Floor Alba Bldg Km 21 West Service Road Cupan
4. g Muntinlupa City Email hir main O gmail com Tel No 02 7722766 65 Contact Technical Department MAIN CONTROL CIRCUIT BOARD ee e TI TRANSFORMER e 1891 W E C X RI FI FUSEIMOTOR me F2 654 FUSE i gt un VI REMOTE RECEIVER o e Jl POWER TERMINAL STRIP e 15 LOW VOLTAGE TERMINAL STRIP VR POTERTIOMETER FOR DELAY TIME SI DIPSWITCH J SWITCH TERMINAL STRIP ERRARE 0 0000 wa ON S1 DIP switch setup 1 OFF DIP1 ON Auto close is valid the delav time is adjustable when rotating potertiometer OFF Auto close is cancled DIP2 ON The red light is on When running OFF The red light is on When closed the green light is on when opened gu Z EN al Ro So Ro Re Ra mmn DETAILED DIAGRAM COM TD ACL AC N LIGHT A TECHNICAL SPECIFICATIONS Model HI R 805AB3 Powertype 220V AC 50 60 Hz Motor Power 90Watts Maximum accessory loads 200mA gt Motor rotation speed 2 800RPM Running Type 3seconds Boom length 3M 4M Number of spring 1 spring 2 springs Temperature 20 degrees to 70 degrees Centigrade Model HI R 805AB6 Power type 220V AC 50 60 Hz Motor Power 90Watts Maximum Accessory loads 200mA Motor rotation speed 2 500RPM Running Type 6 seconds Boom length 6M Number of spring 3 springs Temperature 20 degrees to 70 degrees Centigrade VVVVV VV FIG 1
Download Pdf Manuals
Related Search
Related Contents
Liste online des documents de prêt Brennenstuhl PM 240 E Panasonic WV-NW960 surveillance camera Copyright © All rights reserved.
Failed to retrieve file