5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW
Contents
1. PLANET i E Natworking amp Communication 5 8 Port Industrial Fast Ethernet Switch ISW 500 ISW 800 User s Manual Trademarks Copyright PLANET Technology Corp 2006 Contents subject to which revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and
2. Green Off Meaning When the industrial switch has power input s the LED will light on No any power inputs Power on No power inputs Power on No power inputs The port is linking with its link partner The port is transmitting or receiving packets from the TX device No device attached The port is operating in full duplex mode Collision of Packets occurs in the port The port in half duplex mode or no device attached The port is operating in full duplex mode Collision of Packets occurs The port is in half duplex mode or no device is attached A network device is detected The port is transmitting or receiving packets from the TX device No device is attached 2 1 4 Switch Bottom Panel The bottom panel of the 5 8 Port 10 100BaseTX Industrial Switch consist one terminal block connector within two DC power inputs and one DC IN power jack for extra AC DC power adapter Figure 2 3 shows the bottom panel of the switch a A ES AMOR AN O UY AOO mf Fy OG Cy es LJ LY AA AAJ Kf SP UE AA LJ NY NY NY N a a D E EN N y gt EN a a N a N O O NY UY NY O J C LS GN Y O RIMINI Ce ee aa RY sl Ree MK MUY A MS A AJ A a NJ Y DC IN PWR2 PWR1 Power Input 12 48V DC Figure 2 3 ISW 500 800 Bottom Panel 2 1 5 Wiring the Power Inputs Please follow below steps to insert the power wire PW
3. problem try a different cable 4 1 2 Non standard cables Non standard and miss wired cables may cause numerous network collisions and other network problem and can seriously impair network performance A category 5 cable tester is a recommended tool for every 100Base T network installation 4 1 3 Improper Network Topologies It is important to make sure that you have a valid network topology Common topology faults include excessive cable length and too many repeaters hubs between end nodes In addition you should make sure that your network topology contains no data path loops Between any two ends nodes there should be only one active cabling path at any time Data path loops will cause broadcast storms that will severely impact your network performance 4 1 4 Incorrect Power Input Verify that you are using the right power cord adapter DC 12 48V please don t use the power adapter with DC output bigger than 48V or it will burn this converter down 4 2 Diagnosing LED Indicators The Switch can be easily monitored through panel indicators to assist in identifying problems which describes common problems you may encounter and where you can find possible solutions IF the power indicator does turn on when the power cord is plugged in you may have a problem with power outlet or power cord However if the Switch powers off after running for a while check for loose power connections power losses or surges at power outlet IF
4. you still cannot resolve the problem contact your local dealer for assistance 4 2 1 Cabling RJ 45 ports use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Q Category 3 4 or 5 Cable for 10Mbps connections or 100Q Category 5 cable for 100Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators the Switch can be easily monitored through panel indicators to assist in identifying problems which describes common problems you may encounter and where you can find possible solutions IF the power indicator does not turn on when the power cord is plugged in you may have a problem with power cord Than check for loose power connections power losses or surges at power outlet IF you still cannot resolve the problem contact your local dealer for assistance If the Industrial switch LED indicators are normal and the connected cables are correct and the packets still cannot transmit Please check your system s Ethernet devices configuration or status Appendix A Networking Connection A 1 Switch s RJ 45 Pin Assignments Contact A 2 RJ 45 cable pin assignment DE There are 8 wires on a standard UTP STP cable and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection Cross Over Cable 1234667 6 SIDE 1 ll 12346567865
5. R2 V V V V 1 Insert the positive and negative wires into the V and V connector on the terminal block connector 2 To tighten the wire clamp screws for preventing the DC wires to loose Power Notice The wire range of terminal block is from 12 24 AWG 2 2 Mounting Installation This section describes how to install the Ethernet Switch and make connections to it Please read the following topics and perform the procedures in the order being presented 2 2 1 DIN Rail mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch To hang the industrial switch follow the below steps Step1 Insert the top of DIN Rail into the track Step2 Lightly push the button of DIN Rail into the track Fy wt SSE 2 a EE EE a A A A A A A __ _ _ _ _ m TERETE LT Step3 Check the DIN Rail is tightly on the track Step4 To remove the industrial switch from the track reverse steps above 2 2 2 Wall Mount Plate Mounting To install the switch on the wall please follows the instructions described below Step1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail Step2 Place the wall mount plate on the rear panel of the industrial switch Step3 Use the screws to screw the wall mount plate on th
6. e industrial switch Step4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall Step5 To remove the wall mount plate reverse steps above 3 NETWORK INSTALLATION In this paragraph we will describe how to install the 5 8 Port 10 100Base TX Industrial Switch and the installation points for the attention E 100Base TX Ethernet MIA Cat3 5 UPT STP Cable SE LLL Sa Data Collect Server Human Management Interface Enterprise Switch Industrial Industrial Industrial Switch Switch Switch SS Serial Device Distribute I O Server Control System SIDA El Motors Drives PLC MAMA AAA oH Field Automatic Device Field Automatic Device UN 1 0 Devices Installation Steps Step1 Unpack the Industrial switch Step2 Check the DIN Rail is screwed on the Industrial switch Please refer to DIN Rail Mounting section for DIN Rail installation If the DIN Rail is not screwed on the Industrial switch If you want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation Step3 To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section Step4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for power input The power LED on the Industrial switch will light up Please refer to the LED Indicators section fo
7. e product in case there is a need to return it to us for repair 1 2 How to Use This Manual This User Manual is structured as follows Chapter 2 HARDWARE INSTALLATION The chapter explains the functions of the Switch and how to physically install the Switch Chapter 3 NETWORK INSTALLATION The chapter explains how to install the Switch in the Network Chapter 4 TROUBLE SHOOTING The chapter explains how to trouble shooting of the Switch Chapter 5 APPENDIX A Networking Connection The chapter contains cable information of the Switch 1 3 Product Feature Hardware Feature 0 Comply with IEEE 802 3 IEEE 802 3u CSMA CD Protocol o RJ 45 Port support auto MDI MDI X function o Wide range redundant power design Store and forward switch architecture o DIN rail and 3 way wall mount design Industrial Conformance a 12 48V DC redundant power with polarity reverse protect function and connective removable terminal block for master and slave power o O to 60 Degree C operation temperature o IP 30 Aluminum case o EMI complies with FCC Class A CE EN6100 4 2 CE EN6100 4 3 CE EN6100 4 4 CE EN6100 4 5 and CE EN6100 4 6 a Stability testing with IEC60068 2 32 Free fall IEC60068 2 27 Shock and IEC60068 2 6 Vibration Model Standard 10 100Mbps TP Protocol Switching Architecture Transfer Rate MAC address Memory Buffer Network Cable LED Backplane Packet throughput ability Power Supply Power C
8. found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at whose own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately SS Revision PLANET Industrial Fast Ethernet Switch User s Manual FOR MODELS ISW 500 ISW 800 Revision 1 0 February 2006 Part No EM_ISW500800v1 2011 AHO010 000 Table of Contents INTRODUCTION eiaicedercte ese a denea aaeeea aaaea aae aereas ieee eeaeee Eea 4 ga
9. l re A A a a meee eee 4 1 2 How to Use This Manual ooccoocnccccnccocncconnoconccnnnccnnnonononnnnonnnnnannnnnnnonnnonannonannnnaninnns 4 E A A east saree comecee 4 TA POGUE SD MC cocida 5 2 HARDWARE INSTALLATION saint aa eaa iaaa aa daa aaa aa 6 2 1 Product DESCIIDUON anssen A a a a ot ean a G 6 2 2 MOUNtINO Instala sida ias 9 3 NETWORK INSTALLATION osuna 11 A TROUBLESHOOTIN Gota S 13 AA IPICORFECT COMNE CONS caste ic cugetins sa ol e 13 4 2 Diagnosing LED INACIO Sutil 13 Appendix A Networking Connection cccccccscsssssseeeeeeeeeeeensseeeeseeeeesnseeeeeeseoeenseeeeeesseaes 15 A 1 Switch s RJ 45 Pin Assignments ccccccseeseeccesseeeceeseeeceeseeseageeessageeessauseeeseeseeenes 15 A2 RJ 45 Cable PIN assignment sins canton ideal 15 1 INTRODUCTION The 5 8 Port 10 100BaseTX Industrial Fast Ethernet Switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications It provides the redundant power inputs that prevent the power failure 1 1 Packet Contents Check the contents of your package for following parts o Industrial Fast Ethernet Switch x1 o DIN Rail kit screwed on the switch o Wall mount kit wall mount plate with 6 screws o CD ROM user s manual x1 If any of these are missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them against to repack th
10. limatically demanding environments utilization 2 1 1 Product Overview The switch provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found on plant floors or in curb side traffic control cabinets An operating temperature range of 0 to 60 Degree C coupled with hazardous location certification Class 1 Division 2 allows the switch to be placed in almost any location The switch is packaged in a compact IP 30 standard aluminum that allows either DIN or panel mounting for efficient use of cabinet space The switch provides an integrated power supply with a wide range of voltages 12 48VDC for worldwide operability or dual redundant reversible polarity 24VDC and 48VDC power supply inputs for high availability applications requiring dual or backup power inputs 2 1 2 Switch Front Panel Figure 2 1 shows the front panel of the switch 3 PLANET E a 2 i PLANET Far l Ep FD ee Colle re ACT a I5We 3500 Figure 2 1 ISW 800 Front Panel Figure 2 2 ISW 500 Front Panel LED Power Power 1 Power 2 LNK ACT port 7 amp 8 of ISW 800 port 5 of ISW 500 FDX COL port 7 amp 8 of ISW 800 port 5 of ISW 500 LED Indicator port 1 6 of ISW 800 port 1 4 of ISW 500 2 1 3 LED Indications Status Green Off Green Off Green Off Green Blinks Off Orange Blinks Off Orange Blinking Orange Off Green Blinking
11. onsumption Installation Operating environment Storage environment Dimension W x D x H Emission Stability testing 1 4 Product Specification ISW 500 ISW 800 IEEE 802 3 IEEE 802 3u 10 100Base TX 5 8 CSMA CD Store and forward 144 880 pps for Ethernet port and 1448 800 pps for Fast Ethernet port 1K 2K 512Kbits 1Mbit 10Base T 2 pair UTP STP Cat 3 4 5 cable 100Base TX 2 pair UTP STP Cat 5 cable 10Base T EIA TIA 568 100 ohm 100m Per port Link Activity Green Full duplex Collision Green Per unit Power 2 Green Power 1 Green Power Green 1Gbps 1 6Gbps 0 74Mpps 64bytes 5TX 1 19Mpps 64bytes 8TX 12 48 VDC Redundant power with polarity reverse protection function 2 8 Watts 9 5BTU 4 6 Watts 15BTU Provide DIN rail kit and wall mount plate for 3 way installation 0 60 Degree C 5 90 RH Non condensing 40 85 Degree C 5 90 RH Non condensing 54 x 105 x 155 mm FCC Class A CE mark IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration 2 HARDWARE INSTALLATION This section describes the functionalities of the Switch s components and guides how to install it on the rack or mount to the wall Basic knowledge of networking is assumed Please read this chapter completely before continuing 2 1 Product Description The PLANET entry level Industrial Ethernet Switch is industrially hardened Ethernet switch specifically designed to operate reliably in electrically harsh and c
12. r meaning of LED lights Step5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection Step6 Insert one side of Category 5 cables into the Industrial switch Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex switch Pc or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning 23 Notice Be sure the connected network devices support MDI MDI X If it does not support then use the crossover category 5 Cable Step7 When all connections are all set and LED lights all show in normal the installation is complete 4 TROUBLESHOOTING This section is intended to help you solve the most common problems on the industrial Ethernet switch 4 1 Incorrect connections The switch port can auto detect straight or crossover cable when you link switch with other Ethernet device For the RJ 45 connector should use correct UTP or STP cable 10 100Mbps port use 2 pairs twisted cable If the RJ 45 connector is not correct pin on right position then the link will fail For fiber connection please notice that fiber cable mode and fiber module should be match 4 1 1 Faulty or loose cables Look for loose or obviously faulty connections If they appear to be OK make sure the connections are snug IF that does not correct the
13. y Figure A 1 Straight Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture SIDE 1 1 White Orange 2 Orange 3 White Green d Blue 5 White Blue 6 Green T White Brown 8 Brown SIDE 1 1 White Orange 2 Orange 3 White Green d Blue 5 White Blue 6 Green T White Brown 6 Brown before deploying the cables into your network 2011 AH0010 000 SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green T White Brown 8 Brown SIDE 2 1 White Green 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange T WhitefBrowmn 8 Brown