1. P31300C USER S MANUAL MA17 02 C 09 11 2011 DAVIS CIA www davicia com USER S MANUAL MA17 02 C INDEX 9 DESCRIPTION INSTALLATION 2 1 Scale assembly 2 2 Location and setting 2 3 Startup OPERATION 3 1 LCD symbol description 3 2 Key functions 3 3 Weighing 3 4 Taring 3 5 Hold 3 6 Body Mass Index BMI 3 7 Pre Tare SETUP 4 1 Connecting with PC 4 2 Print function MAINTENANCE AND CLEANING 5 1 Instructions for charge and connect 5 2 Instructions for replacing batteries 5 3 Environmental 5 4 Equipment disposal TROUBLESHOOTING HEIGHT ROD ACCESSORIES 7 1 Height rod assembly 7 2 Battery installation 7 3 Key functions 7 4 Calibrating the height rod 7 5 Using the height rod 7 6 Technical Specifications AUTOMATIC HEIGHT ROD ACCESSORIES 8 1 Height rod assembly 8 2 Using the height rod 8 3 Connecting with PC 8 4 Technical Specifications TECHNICAL SPECIFICATIONS 10 WARRANTY CERTIFICATE 11 CE DECLARATION OF CONFORMITY o Q N 0 A SS WO CO CON N N OD OD 13 13 13 13 13 14 15 15 16 17 17 18 19 20 20 21 22 22 23 24 25 USER S MANUAL MA17 02 C 1 DESCRIPTION 1 Display unit 2 Mounting holes for height rod accessories 3 Scale platform 4 Adjustable feet 5 Level U USER S MANUAL MA17 02 C 2 INSTALLATION Before putting the device into use please read with care the information given in t
2. equipment CUMPLE LOS REQUISITOS DE LAS DIRECTIVAS CONFORMS WITH THE REQUISITES OF THE DIRECTIVES EC Directive 2004 108 EC Directiva de Compatibilidad Electromagnetica Electromagnetic Compatibility Directive EC Directive 2006 95 EC Directiva de Baja tension Low Voltaje Directive EC Directive 93 42 EEC Aplicable nicamente a las b sculas con aprobaci n m dica Applies only to scales with medical approval AC1200D y AC1200M cumplen con la Directiva 93 42 EEC Clase AC1200D and AC1200M are in accordance with Directive 93 42 EEC Class l FECHA 12 de Diciembre de 2010 DATE 12 December 2010 Nombre J Masana Name Firmado Cargo Gerente Function DAVI 8 CIA 25 USER S MANUAL MA17 02 C This manual and other support documents are available on the web www davicia com DAVI amp CIA C Murcia 35 Nave G Pol industrial Can Calderon Tel 3493 654 32 32 info adavicia com E 08830 Sant Boi de Llobregat Barcelona Spain Fax 34 93 654 16 62 www davicia com 26
3. routine maintenance However we recommend checking the scale s accuracy at regular intervals The regularity of these checks is dependent on the level of use and the state of the scale o We would recommend using alcohol based wipes or similar when cleaning the scale o Please do not use large amounts of water when cleaning the scale as this will cause damage to the scale s electronics you should also refrain from using corrosive liquids or high pressure washers o Always disconnect the scale from the main power supply before cleaning 5 1 INSTRUCTIONS FOR CHARGE AND CONNECT If Lo is displayed on the LCD you should charge scale with AC adaptor Locate adaptor plug at the rear of indicator CAUTION Always connect the AC adaptor to the indicator before connecting to the main power supply Please disconnect the adaptor from ma n power supply before indicator 5 2 INSTRUCTIONS FOR REPLACING BATTERIES o Remove the battery cover o Take the battery housing out o Replace new batteries o Make sure batteries are well installed o Reinstall the battery housing 1 Reinstall the battery cover 5 3 ENVIRONMENTAL All batteries contain toxic compounds disposal of batteries should be delegated to a competent organization complying with the deposit of Poisonous Waste Regulation 1972 Please do not incinerate batteries The optimum operating temperature for the scale is 5 C to 35 C although it will operate at higher and lower temp
4. used as mechanical height measurement rod For mechanical measurement range starts from 60 200cm making it an ideal measurement rod for measuring height of E children and adults as well 7 1 HEIGHT ROD ASSEMBLY 1 Fixing the bracket on the column of the scale using the screws provided with the height rod 15 USER S MANUAL MA17 02 C 2 Extend the height measuring rod and tighten it in the bracket with the help of the appertaining screw 7 2 BATTERY INSTALLATION AC1200M don t need batteries to operate AC1200D a Remove the battery cover at the rear of indicator b Install 2 AAA size batteries c Putthe batter cover back WARNING If the height rod is not in use for long time take out the batteries and store them separately in case of any leakage trom battery would damage the measuring rod NOTE When the new batteries have been installed it is recommended to reset the height rod using reset key 16 USER S MANUAL MA17 02 C 7 3 KEY FUNCTIONS Keys Description S O ON OFF Press to switch on and off UNIT To select the measurement unit between cm and inch To enable value store function during measuring Current height value of user will be stored and displayed Press again to disable the function RESET key is for user to calibrate false reading Slide right feet piece to the left at length of 35cm Press RESET key to calibrate the height rod LCD will display 35 0cm which means t
5. ANTY CERTIFICATE We provide a 1 year guarantee from the date of purchase The guarantee covers manufacturing defects or defects occurring as a result of normal use and operation It excludes all removable parts such as batteries wires power supply devices etc Faults falling within the guarantee period shall be rectified free of charge upon presentation of the purchase receipt for the appliance No other rights can be taken into consideration Return shipment is at the customer s expense if the appliance is anywhere other than at the customer s headquarters In the event of damage during shipment guarantee rights will be granted only if the appliance is shipped in the original packaging You are therefore recommended to keep the original packaging Following expiry of the guarantee period all services requested will be dealt with by our specialist technicians at the user s expense 24 USER S MANUAL MA17 02 C 11 CE DECLARATION OF CONFORMITY CE DECLARATION OF CONFORMITY FABRICANTE PRODUCTO DAVI amp CIA S L PRODUCT MANUFACTURER DIRECCION C Murcia 35 Nave G ADDRESS Poligono Industrial Can Calderon E08830 Sant Boi de Llobregat BARCELONA ESPANA DECLARAN BAJO SU RESPONSABILIDAD QUE EL PRODUCTO DECLARE UNDER THEIR RESPONSIBILITY THAT THE PRODUCT Marca DAVI amp CIA Brand Nombre PS1300C Name Tipo EQUIPO ELECTRONICO Type Electronic equipment Finalidad Prevista Equipo pesapersonas Intended Use Weighing
6. eight rod and the indicator then to the socket Plug the communications cable COM both to the height rod and to the indicator 20 USER S MANUAL MA17 02 C 8 2 USING THE HEIGHT ROD Turn on the indicator by pressing the ON OFF Step on the platform and wait for the stable O button Do not step on the platform before 0 0 sign to appear on display The scale will beep appears on display once Then press the BMI button Height will be automatically measured and shown on display NOTE It is recommended that this action will be assisted to ensure that the person on the platform is standing fully straight at the time of the measurement Otherwise the result may not be exact The result of the height and body mass index appear alternately on the screen To return to the scale to weight measurement press the BMI button 21 USER S MANUAL MA17 02 C 8 3 CONNECTING WITH PC If you d like to send the measurement results to a computer plug in the PC communications cable to the height rod 8 4 TECHNICAL SPECIFICATIONS Model AC3200D Scale mounted automatic height rod 0 200cm Dimensions 122x530x1630mm Weight 1 4kg 22 USER S MANUAL MA17 02 C 9 TECHNICAL SPECIFICATIONS Power supply AC adapter 15V 300mA Rechargeable Battery Key Functions ON OFF ZERO PRINT BMI HOLD PRE TARE TARE CLEAR ENTER 0 9 M1 5 Operation temperature 5 C 735 C 23 USER S MANUAL MA17 02 C 10 WARR
7. er calibration zero Please recalibrate the instrument range 10 while power on Zero count under calibration zero Please recalibrate the instrument range 10 while power on EEPROM Error Indicates that This error is normally caused by a serious fault on there is a fault with the scale s the scales such as faulty load cell or wiring Please software contact the local service representative 14 USER S MANUAL MA17 02 C 7 HEIGHT ROD ACCESSORIES AC1200D AC1200D is a digital height rod to be mounted on the scale with measuring range from fa s 120 200cm AC1200D have LCD display for convenient accurate and quick height o measurement lt can be connected with the scale indicator to transfer the height Y measurements directly therefore while calculating BMI the users don t need to enter the height Simply step on the weighing platform and as the weight stabilizes adjust the head piece to measure the height the scale will display the height and BMI results de AC1200M AC1200M is a mechanical height rod to be mounted on the scale with measuring range of 120 200cm AC1200M don t have LCD display instead it automatically transfers the height measurement to weighing scale therefore while calculating BMI the user don t need to enter the height Simply step on the weighing platform and as the weight stabilizes adjust the head piece to measure the height the scale will display the height E and BMI results It can also be
8. eratures the scale s battery life will adversely be affected 5 4 EQUIPMENT DISPOSAL All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities This crossed out wheeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of the equipment will help prevent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment 13 USER S MANUAL MA17 02 C 6 TROUBLESHOOTING Error Message Reason Action Low Battery This warning shows Please replace a new battery or plug the AC that the voltage of battery is too adaptor for operation low to use Overload The total load exceeds Please reduce the loading and try again the maximum capacity ofthe scale Counting error too high Indicates This error is normally caused by a serious fault on that the signal from the load cellis the scales such as faulty load cell or wiring Please too high contact the local service representative Counting error too low Indicates This error is normally caused by a serious fault on that the signal from the load cellis the scales such as faulty load cell or wiring Please too low contact the local service representative Zero count ov
9. gn will appear on the display Press numeral key 1 5 to assign the position to pre tare weight USER S MANUAL MA17 02 C The instrument will make flash and beep sound and will display the saved Pre Tare Weight Recall Pre Tare Value Long press PRE TARE key for 3 seconds the display will show the blinking m sign Press ENTER key to confirm the pre tare weight the instrument will automatically perform tare function Press PRE TARE key to return to Normal Mode 10 4 SETUP USER S MANUAL MA17 02 C Switch ON the scale and long press ZERO key for 3 seconds First SETUP and then A OFF will display successively Auto off time setup This enables operator to select the auto turn OFF time of the device Auto off time 120 sec 180 sec 240 sec 300 sec Off Buzzer on off setup This enables operator to select beep sound ON OFF Buzzer On Off Press ZERO key 3 seconds HOLD sEEUP era DFF 20S 805 2405 3005 FPF key means ADFF a i e blir rF N On OFF End NOTE To confirm the settings please press HOLD when END displays on the display 4 1 CONNECTING WITH PC The equipment can be connected to PC to transfer the weighing results 1 Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication gt Hype
10. he Operating Instructions They contain important instructions for installation proper use and maintenance of the device The manufacturer shall not be liable for damages arising out of failure to heed the following instructions o When using electrical components under increased safety requirements always comply with the appropriate regulations Improper installation will render the warranty null and void Ensure the voltage marked on the power supply unit matches your main power supply This device is designed for use indoors Observe the permissible ambient temperatures for use The device meets the requirements for electromagnetic compatibility Do not exceed the maximum values specified in the applicable standards O O O O y 2 1 SCALE ASSEMBLY 1 Assembling column with base 2 Connecting wire between column and base 3 Tightening four screws at the bottom of base Assembling is complete 2 2 LOCATION AND SETTING We strongly recommend you use this device on flat and hard surface Any soft surface like carpet will cause inaccuracy USER S MANUAL MA17 02 C 2 3 STARTUP o Connect the equipment to the power supply using the AC adaptor o Press the ON OFF button in the indicator o Wait until O appears on display USER S MANUAL MA17 02 C 3 OPERATION Before reading detailed instructions on how to use all the weighing functions that are built into your scale please read the following important guidel
11. he height rod has been well calibrated 7 4 CALIBRATING THE HEIGHT ROD AC1200D o Slide the measuring rod downward completely o Turn ON AC1200D using ON OFF key o Ifthe height display is not on 120cm press Reset button to calibrate the height It will be 120cm AC1200M Connect AC1200M with indicator Turn ON the scale by pressing ON OFF key Press BMI key to check current height Slide the measuring rod downward completely If the height display is not 120cm press Reset button to calibrate the height It will be 120cm O O O O 17 USER S MANUAL MA17 02 C 7 5 USING THE HEIGHT ROD AC1200D 1 Slide up the measuring rod upward 2 Slide down the head piece until slightly touches the head 3 When the head piece touches the head of the person display will show the exact height of the person 4 Tolock the height on the display press HOLD key 5 Press HOLD key again to disable the Hold function Connecting USB wire to the scale will enable height transfer function You can calculate BMI with height and weight taken by height rod and scale Measuring height lower than 120 cm AC1200M 1 Slide the measuring rod upward 2 Slide down the head piece until slightly touches the head 3 When the head piece touches the head of the person display will transfer height data to the scale 4 You can use BMI functions of scale to recall and calculate BMI weig
12. ht and height Connecting USB wire to the scale will enable height transfer function You can calculate BMI with height and weight taken by height rod and scale Please use AC1200M as a mechanical height rod and press buckle as shown in the picture below and slide the head piece down 18 USER S MANUAL MA17 02 C 7 7 TECHNICAL SPECIFICATIONS AC1200D AC1200M Scale mounted digital height rod Hold Reset Unit Reset Button 120 200cm Digital measuring range Measurement range 120 200cm 60 200cm Mechanical measuring range Imm Dimensions soono o Power Supply 2 AAA sizebatteries 2 19 USER S MANUAL MA17 02 C 8 AUTOMATIC HEIGHT ROD ACCESSORIES AC3200D AC3200D is an automatic height rod to be mounted on the scale with measuring range from 0 200cm AC3200D is connected with the scale indicator to transfer the height measurements directly therefore while calculating BMI the users don t need to enter the height Simply step on the weighing platform and as the weight stabilizes press a button to measure the height the scale will display the height and BMI results 8 1 HEIGHT ROD ASSEMBLY 1 AC3200D is delivered with the top part 2 Fix the top part of the height rod using the loose and folded Do not pull from this part longest screw as cables could get damaged 3 Fix the height rod to the scale by screwing 4 Connect the power supply cable PS to the the bracket to the column h
13. ines o Always be sure that the display shows Zero before use if it does not then please press the ZERO key o The equipment is designed to detect when a stable weight is achieved your reading should be taken at this point 3 1 LCD SYMBOL DESCRIPTION PRE TARE Indication HOLD Indication NET WEIGHT Indication to Indication Stable NN j 40 Minor weight lt ___ a gt Zero symbol lt Low Battery lt __ Description Zero symbol If the scale does not show exactly zero value although the scale pan is unloaded press the 0 lt key After a short waiting time the scale will be zeroed again Stable symbol If the display shows the stabilization display o the scale is in the stable condition When the scale is in the unstable condition the stabilization display o disappears Minor weight Weight under zero LOW Low Battery Battery need to change or replace USER S MANUAL MA17 02 C 3 2 KEY FUNCTIONS PRE HOLE TARE MET WEHT DAVI amp CIA Data transmission via interface Print out the results Determine Body Mass Index To hold weighing result on the display determine stable weighing value To reset the display to 0 0kg display Zero the scale 2 of full capacity To store 5 pre tare values Setup target weight for tare before weighing Tare weight during weighing process To clear the wrong entry while entering digits To confirm the performing functions Functio
14. n ON OFF switch Turn ON OFF the scale 3 3 WEIGHING Switch on the scale with the ON OFF key The diagnostic scale self check is performed and then the software version is displayed The scale is ready for weighing when the 0 00 kg weight display is shown NOTE If 0 00 kg won t display on the screen press gt 0O key to zero the scale 50 can be used any time to zero the scale Place a person in the middle of the scale Wait until the stability display 0 is shown and then read the weighing result DIRECTION Ifa person is heavier than the weighing range the display will show the Err symbol overload 3 4 TARING Tare allows the user to zero the instrument to cancel the weight of a container clothes from the reading of the instrument thus giving the true weight of the product person being tested o Turn onthe scale using ON OFF key USER S MANUAL MA17 02 C o When 0 00 kg displays on the screen and scale beeps twice place the object clothes to be tared on the tray o Press TARE key after the weight stabilizes and stable sign appears on the display o Display will return to 0 00 kg o Place the item baby to be weighed without removing the tare object The weighing result is the Net weight of the item baby To delete the saved tare value remove the tare object from the tread platform and press TARE key 3 5 HOLD The scale is provided with the integrated hold functio
15. n determination of average value It enables people to be weighed accurately although they are not still on the scale plate NOTE Determination of average value is not possible when a person moves too much O Switch on the scale with the ON OFF key The scale self check diagnostic is performed The scale is ready for weighing when the 0 00 kg weight display is shown Place a person in the centre of the scale plate Press the HOLD key When the triangle is flashing on the display the scale takes some measuring values and then the calculated average value is displayed Remove the object baby from the scale platform The object baby s weight reading will remain on the display Press the HOLD key again to return the scale to the normal weighing mode HOLD function can be activated before or after putting the weight on the platform In case of weighing babies that move alot it is recommended to press HOLD key before the person moves on the platform 3 6 BODY MASS INDEX BMI For BMI calculation height is needed therefore it is recommended to measure the height of subject before starting weighing procedure o Turn ON the scale using ON OFF key o Proceed to weigh as normal o After the weight is stable and stable sign displays on the screen press BMI key o Display will change to 0 00 kg o Key in the height of the person using numeric keys 0 9 Example 186cm the height should be in centimeters o P
16. r Terminal 2 New Connection Description Give new connection a name then click OK 3 Select Your COM Port Click Connect to select your COM port Usually there s only one option for select Then click OK 4 Port Settings Click Bits per second to set up rate at 9600 Data bits at 8 Parity at None Stop bits at 1 and Flow control at Hardware Then click OK to complete your setting 5 Output Data When the patient has been weighed and BMI calculated simply press the PRINT key to output data from scale to PC or an Optional Printer Parameters of RS232 interface Set parameters of the scale interface on the connected device It is not possible to change the scale parameters o Baudrate 9600 bps 11 USER S MANUAL MA17 02 C Parity check None Data length 8 bits Stop bit 1 bit Handshake RTS CTS Data code ASCII O O O O 4 2 PRINT FUNCTION The Weighing BMI and Height results can be printed out for records using RS232 interface cable included in accessory kit which is connected with the round plug at the back terminal After weighing and calculating BMI simply press PRINT key to print out the results The format presented below is the standard format of results print out and cannot be changed GROSS WEIGHT 88 8 kg TARE WEIGHT 2 0kg NET WEIGHT 86 8 kg PATIENT HEIGHT 188 5 cm PATIENT B M 24 4 12 USER S MANUAL MA17 02 C 5 MAINTENANCE AND CLEANING The scale does not require any
17. ress ENTER to confirm the Display will show the B M I of the person o Press BMI again to return to normal mode Categories of BMI Classification of weight for adults over 18 years on the basis of Body Mass Index according to WHO 2000 EK IV and WHO 2004 WHO World Health Organization Category BMI kom Risk of diseases accompanying overweight Underveight Normal weight 18 5 24 9 average Overweight 25 0 Preobesity 23 0 29 9 slightly increased I degree of obesity 30 0 34 9 increased Il degree of obesity 35 0 39 9 high Ill degree of obesity gt 40 very high USER S MANUAL MA17 02 C 3 7 PRE TARE The scale can store 5 sets of pre tare values and there are two methods to store pre tare value Using Dead Weight or Enter weight using 0 9 keys Using Dead Weight Press M1 5 key after loading the weight the display will show blinking m sign Press numeral key 1 5 to assign the position to pre tare weight For example Press 1 to assign position 1 to preset tare weight The display will blink and makea beep sound NOTE You can assign any other position from 1 5 to pre tare weight Enter Weight Using 0 9 Keys Press PRE TARE key and the extreme left digit will blink Enter PRE TARE weight using 0 9 keys For example 10kg Press ENTER key to confirm the pre tare weight the display will show the minus sign on left of the pre tare weight value Press M1 5 key the blinking m si
Download Pdf Manuals
Related Search
Related Contents
Oxford®/Hoyer® Arise KitchenAid KGCU467VSS Instructions / Assembly Installation suggestions Suggestions d`installation EverFocus EQ150 User's Manual MSI Gaming GS60-2PMi581 F PRO SERIE - Irrigation Ultra-Compact Digital Mixer ITI CareTaker EZ Owner`s Manual Pyrotenax® MI Cable Industrial Wiring Installation Manual Samsung Aspirapolvere SC9100 con sacco, Multi Chamber System™, 1600 W User Manual Copyright © All rights reserved.