Home
User Manual - BC Group International Inc.
Contents
1. a0 1 0 Adult ST D m Artf mone 30 BrP 1 0 ohms aF 0C 98 6 F BLOOD PRESSURE SCREEN The Blood Pressure screen shows the output settings for the Patient Simulator Invasive Blood Pressure Output 2 Static 2 Static a Static d Static Group Settings pn NOTE Not all patient simulators have four blood pressure channels Changes made to blood pressure channels that are not present on the patient simulator will not affect the performance or operation of the patient simulator NOTE Blood Pressure is not active for all operating modes OPERATING MODE SCREEN This screen shows a list of the available Operating Modes This allows for quickly changing between output modes The last list item allows for access to the Remote Control Setup screen Operating Normal Sinus Rhythm Arrhythmias Pacemaker Performance Fetal Maternal ADDITIONAL SCREENS There are two additional screens Remote Control Setup and Key List REMOTE CONTROL SETUP SCREEN This screen shows the setup for the remote control It can be accessed as the last item on the Operating Mode Screen The user can select an Auto Off period change the LCD Contrast as well as view the Battery Life and Firmware Version See Setup for more information Remate Control Setup Auto Off Timer chin 0 Backlight Timer Sec B 3256 Battery Life LCD Contrast 15 Software DT 343CC KEY
2. INSTALLING THE CONFIGURATION UTILITY To install the windows based configuration utility simply put the CD into your computer s drive and follow the on screen instructions If the CD does not auto run browse to the files contained on the CD and run the SETUP EXE program RUNNING THE CONFIGURATION UTILITY At the end of the installation process you will be prompted to run the configuration utility You can start the program at this time or close the installation program and run the Configuration Utility from an icon that was added to your desktop NOTE If the USB to Serial port converter is used the drivers must be installed before running the utility MAIN CONFIGURATION SCREEN AT A GLANCE This section is utilized to program a key sequence To end a sequence set the last step s time delay to 0 BC Biomedical MPS450 Remote Control Configurabr Ver 1 2 E 5 File Edit About Use this section of the Select a key below to view its current A 5 configuration Make changes to the 5 Normal Sinus Rhythm Screen to view configuration using the screen at right Heart Amplitude Patient Type or change the 80 BPM 10my Adult 7 configuration ST Elevation ECG Artifact of the Patient oov None al Simulator for Respiration Rate Respiration Amplitude the selected 30 BIPM Key Temperature 37 0C 98 6F x Blood Pressure Output Selection Artifact Use these buttons to sele
3. Parameter Description Range Auto Off Timer Min Determines the period of inactivity before the unit is turned OFF A timer is started when the unit is turned ON and is reset each time a key is pressed When the timer reaches the value set in this parameter the power is automatically turned OFF NOTE Setting this parameter to 0 disables the Auto Off timer When running from line power the unit does not automatically shut off Auto Off timer is inactive during a test 0 30 Minutes Backlight Timer Off Always off 1 20 sec The elapsed time after which the backlight will automatically turn off Always ON The backlight will be on Off 1 20 sec Always On Battery Life Displays current life of the battery At 1095 a warning screen will appear At 096 the unit will power down automatically 0 100 Read Only LCD Contrast Sets the contrast of the display screen 0 20 Software Displays current software program Read Only 10 OPERATIONS CONFIGURATION USING A PC The remote control can be easily programmed through a serial port on any Windows based computer For laptops and computers that do not have a serial port a USB to serial port adapter can be used This utility program can also be used to clone a specific remote control setup to multiple remotes once the initial remote control is configured and the key configuration file has been stored to the PC
4. WARRANTY BC GROUP INTERNATIONAL INC WARRANTS ITS NEW PRODUCTS TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP UNDER THE SERVICE FOR WHICH THEY ARE INTENDED THIS WARRANTY IS EFFECTIVE FOR TWELVE MONTHS FROM THE DATE OF SHIPMENT EXCLUSIONS THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE BC GROUP INTERNATIONAL INC IS NOT LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES NO PERSON OTHER THAN AN OFFICER IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR ASSUME ANY LIABILITY REMEDIES THE PURCHASER S SOLE AND EXCLUSIVE REMEDY SHALL BE 1 THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS OR PRODUCTS WITHOUT CHARGE 2 AT THE OPTION OF BC GROUP INTERNATIONAL INC THE REFUND OF THE PURCHASE PRICE P MANUALS BC Group PSR 2200 PSR 2200 MP_UM_Rev02 doc 21 SPECIFICATIONS PHYSICAL LCD Graphical 128 X 64 Pixels rbd White LED Backlight ENCLOSURE ABS Plastic NSTRUCTION FACE PLATE Lexan Back printed 5 98 x 3 27 x 1 28 Inches PEE 151 9 x 83 1 x 32 5 mm WEIGHT 1 Lbs 0 45 kg OPERATING RANGE 15 to 40 C 59 to 104 F STORAGE RANGE 20 to 65 C 4 to 149 F ELECTRICAL 9V Alkaline Battery 1 Required 1604 Alkaline or equivalent 22 APPENDIX A STANDARD CONFIGURATION OUTPUTS There are eleven keys on the remote
5. and to view edit the Keyname Key Sequence Jep notionis When a key is set to run a sequence this window is used to program Ca hor each step of the sequence the delay between each step and the action C3 0 vj to be taken at the end of the sequence Each step can be programmed C4 o x to a specific Operating Mode The delay between steps is c5 fo x programmable from 1 to 600 seconds If any step delay is set to 0 C 6 seconds the sequence will end at that step At the end of the c fp sg q p E sequence the remote can be setto halt at the current setting or to jump fo x to a specific programmable key Nested sequences can be performed zi by programming multiple key sequences and having the end of one At End of Sequence sequence jump to another Goto Keyl Trending Capabilities Through the use of Key Sequences the PSR 2200 MP is capable of running an endless loop of trended patient physiological data The 18 separate programmable keys each of which can be programmed with unique waveform outputs for up to 600 seconds each can be daisy chained to create a trending pattern with up to 180 unique steps and with a total trend duration of up to 108 000 seconds 30 hours worth of waveform data The PSR 2200 MP comes with a pre programmed set of sequence data already assigned to specific keys as listed in Appendix B PRE PROGRAMMED OUTPUTS Control Buttons Read Download to Cancel Remote Remote Chang
6. Mini Din F to DB 9F For PC to Remote Programming 20 41338 COMMUNICATION CABLE Mini DIN F to DB 9M For remote to MPS 450 Marq III OPTIONAL ACCESSORIES BC20 41339 COMMUNICATION CABLE ADAPTER USB to DB 9M For use with BC20 41342 LAYOUT This section looks at the layout of the PSR 2200 MP gives descriptions of the elements that are present 20 Dual Purpose Light Touch Keys 10 keys for control and configuration 10 Fixed function keys 18 Programmable keys LCD Graphical Display with Backlight Shows configuration and output setup 25 Coiled Cable For connection to a PC or Patient Simulator 5 20 soft touch keys are provided for system operation A Pressing and holding this key for 3 seconds will turn the unit off Pressing and releasing this key will toggle NUM LOCK MODE Num Lock mode is identified by a NUM icon in the upper right corner of the screen Bq These keys will change the selected item on the screen The selected item will be highlighted E b Inthe SELECT MODE if a parameter has been highlighted these keys with scroll through the available settings This key allows the user to exit the Choices Menu or cancel a selection that has ES not been entered This key selects a changed option This key is used to show a list of available choices for the selected setting This key toggles the display mode The a
7. 40 BrPM 15 seconds 4 60 BPM 60 BrPM 15 seconds 5 80 BPM 80 BrPM 15 seconds 6 90 BPM 80 BrPM 15 seconds 7 100 BPM 100 BrPM 15 Seconds 8 120 BPM 120 BrPM 15 Seconds 9 140 BPM 120 BrPM 15 Seconds 10 180 BPM 120 BrPM 15 Seconds End of Sequence Action Repeat Sequence from Step 1 37 Ventricular Fibrillation Common Configuration for V Fib Outputs Parameter Setting ECG Amplitude 1 0 mV Patient Mode Adult ST Segment 0 mV ECG Artifact None Respiration 30 BrPM Respiration Resistance 10 Temperature 37 0 C 98 6 F BP Channel Settings 0 mmHg KEY 18 V Fib Sequence Step Waveform Duration 1 NSR 80 BPM 30 seconds 2 Run of 5 PVCs 30 seconds 3 NSR 80 BPM 30 seconds 4 Run of 11 PVCs 30 seconds 5 Ventricular Tachycardia 15 seconds 6 Ventricular Fibrillation Course 10 seconds 7 Ventricular Fibrillation Fine 10 seconds 8 Asystole 10 seconds 9 Not Used 10 Not Used 5 End of Sequence Action Repeat Sequence from Step 1 38 5 39 NOTES 40 PARS BC Group 7 YOUR ONE STOP BioNBE Ei BC GROUP INTERNATIONAL INC 3081 ELM POINT INDUSTRIAL DRIVE ST CHARLES MO 63301 USA 1 800 242 8428 1 314 638 3800 www bcgroupintl com sales bcgroupintl com PSR 2200 MP User Manual 09 12 Rev 02 Copyright 2012 Made in the USA
8. ECG Artifact None Respiration 30 BrPM Respiration Resistance 10 BP Channel Settings 0 mmHg KEY 9 Temperature Sequence Step Temperature Duration 1 0 C 32 0 F 15 seconds 2 24 C 75 2 F 15 seconds 3 37 C 98 6 F 15 seconds 4 40 C 104 0 F 15 seconds 5 Not Used 6 Not Used 7 Not Used 8 Not Used 9 Not Used 10 Not Used End of Sequence Action Repeat Sequence from Step 1 31 Arrhythmias Common Configuration for Arrhythmia Outputs Parameter Setting ECG Amplitude 1 0 mV Patient Mode Adult ST Segment 0 mV ECG Artifact None Respiration 30 BrPM Respiration Resistance 10 Temperature 37 0 C 98 6 F BP Channel Settings 0 mmHg KEY 10 Premature Sequence Step Premature Arrhythmia Waveform Duration 1 Atrial PAC Auto 60 seconds 2 PNC Auto 60 seconds 3 PVC 1 Auto 60 seconds 4 PVC 1 Early Auto 60 seconds 5 PVC 1 Ron T Auto 60 seconds 6 PVC 2 Auto 60 seconds 7 PVC 2 Early Auto 60 seconds 8 PVC Ron T Auto 60 seconds 9 Multifocal PVC Auto 60 seconds 10 Not Used End of Sequence Action Repeat Sequence from Step 1 32 KEY 11 Supraventricular Sequence Step Supervent Arrhythmia Waveform Duration 1 Atri
9. be serviced if any parts are in question CAUTION CLEANING Do not immerse The PSR 2200 MP should be cleaned by wiping gently with a damp lint free cloth A mild detergent can be used if desired CAUTION LIQUIDS Do not submerge or spill liquids on the PSR 2200 MP Do not operate the PSR 2200 MP if it may have been exposed to fluid CAUTION ENVIRONMENT Exposure to environmental conditions outside the specifications can adversely affect the performance of the PSR 2200 MP Allow the PSR 2200 MP to acclimate to specified conditions for at least 30 minutes before attempting to operate it NOTICE ABBREVIATIONS ANSI American National Standards Institute Beats Per Minute Celsius degree s Device Under Test Electrocardiogram Fahrenheit hertz International Electrotechnical Commission pounds Light Emitting Diode millimeter s millivolt s National Electronic Distributors Association United States of America Volt s NOTICE DISCLAIMER BC GROUP INTERNATIONAL INC WILL NOT BE RESPONSIBLE FOR ANY INJURIES SUSTAINED DUE TO UNAUTHORIZED EQUIPMENT MODIFICATIONS OR APPLICATION OF EQUIPMENT OUTSIDE OF THE PUBLISHED INTENDED USE AND SPECIFICATIONS NOTICE DISCLAIMER BC GROUP INTERNATIONAL INC RESERVES THE RIGHT TO MAKE CHANGES TO ITS PRODUCTS OR SPECIFICATIONS AT ANY TIME WITHOUT NOTICE IN ORDER TO IMPROVE THE DESIGN OR PERFORMANCE AND TO SUPPLY THE BEST POSSIBLE PRODUCT THE INFORMATION IN THIS MANUAL HAS
10. 0 Hz 10 seconds 4 Triangle Wave 2 500 Hz 10 seconds 5 Not Used 6 Not Used 7 Not Used 5 8 Not Used 9 Not Used 1 10 Not Used 1 End of Sequence Action Repeat Sequence from Step 1 24 KEY 2 Sine Waves Sequence Step Waveform Duration 1 Sine Wave 0 1 Hz 10 seconds 2 Sine Wave 0 5 Hz 10 seconds 3 Sine Wave 5 0 Hz 10 seconds 4 Sine Wave 10 Hz 10 seconds 5 Sine Wave 40Hz 10 seconds 6 Sine Wave 50Hz 10 seconds 7 Sine Wave 60 Hz 10 seconds 8 Sine Wave 100 Hz 10 seconds 9 Not Used 10 Not Used End of Sequence Action Repeat Sequence from Step 1 KEY Pulse Wave Sequence Step Waveform Duration 1 Pulse Wave 30 BPM 10 seconds Pulse Wave 60 BPM 10 seconds Pulse Wave 90 BPM 10 seconds Not Used Not Used Not Used Not Used Not Used Not Used Not Used End of Sequence Action Repeat Sequence from Step 1 25 KEY 4 Step Waveform Duration 1 Triangle Wave 2 500 Hz 10 seconds 2 Triangle Wave 2 500 Hz 10 seconds 3 Triangle Wave 2 500 Hz 10 seconds 4 Triangle Wave 2 500 Hz 10 seconds 5 Triangle Wave 2 500 Hz 10 seconds 6 Triangle Wave 2 500 Hz 10 seconds 7 Not Used 8 Not Used 9 Not Used 5 10 Not Used End of Sequence Action Re
11. 10 seconds 7 80 BrPM 10 seconds 8 100 BrPM 10 seconds 9 120 BrPM 10 seconds 10 Not Used E End of Sequence Action Repeat Sequence from Step 1 28 KEY 7 Apnea Sequence Step Respiration Rate Duration 1 30 BrPM 30 seconds 2 12 Second Apnea 30 sec step time 3 30 BrPM 30 seconds 4 22 Second Apnea 30 sec step time 5 30 BrPM 30 seconds 6 32 Second Apnea 60 sec step time 7 30 BrPM 10 seconds 8 Apnea 15 seconds 9 Not Used 5 10 Not Used 2 End of Sequence Action Repeat Sequence from Step 1 29 ECG Artifact Common Configuration for Artifact Outputs Parameter Setting ECG Waveform iue M ECG Amplitude 1 0 mV Patient Mode Adult ST Segment 0 mV Respiration 30 BrPM Respiration Resistance 10 Temperature 37 0 C 98 6 F BP Channel Settings 0 mmHg KEY 8 ECG Artifact Sequence Step Artifact Duration 1 None 15 seconds 2 50 Hz Noise 15 seconds 3 60 Hz Noise 15 seconds 4 Muscle 15 seconds 5 Baseline Wander 15 seconds 6 Respiration 15 seconds 7 Not Used 8 Not Used 9 Not Used 10 Not Used x End of Sequence Action Repeat Sequence from Step 1 30 Temperature Common Configuration for Temperature Outputs Parameter Setting ECG Waveform iue M ECG Amplitude 1 0 mV Patient Mode Adult ST Segment 0 mV
12. BEEN CAREFULLY CHECKED AND IS BELIEVED TO BE ACCURATE HOWEVER NO RESPONSIBILITY IS ASSUMED FOR INACCURACIES NOTICE CONTACT INFORMATION BC BIOMEDICAL BC GROUP INTERNATIONAL INC 3081 ELM POINT INDUSTRIAL DRIVE ST CHARLES MO 63301 USA 1 800 242 8428 1 314 638 3800 www bcgroupintl com sales bcgroupintl com PSR 2200 MP User Manual Copyright 2012 www bcgroupintl com Made in the USA 09 12 Rev 02 BC BIOMEDICAL PSR 2200 MP PATIENT SIMULATOR REMOTE CONTROL The Model PSR 2200 MP is a Microprocessor based remote control for use with the model MPS 450 patient simulator series The remote allows the user to configure the patient simulator and provides pre programmed configurations as well as programmable key functions and key sequences The following are highlights of some of the main features 10 FIXED FUNCTION KEYS 18 PROGRAMMABLE FUNCTION KEYS PROGRAMMABLE KEY NAMES UP TO 20 CHARACTERS 10 STEP KEY SEQUENCE PROGRAMMABILITY UP TO 30 HOURS WORTH OF TRENDING CAPABILITY PC INTERFACE FOR SIMPLE CONFIGURATION LARGE GRAPHICS DISPLAY WITH CURSOR SELECTION OF OPTIONS AND SETUP OF PARAMETERS DISPLAY BACKLIGHT WITH ADJUSTABLE TIMER BATTERY LIFE DISPLAY 0 TO 100 SOFTWARE ADJUSTABLE CONTRAST PROGRAMMABLE AUTO SHUTDOWN TO CONSERVE BATTERY LIFE e FLASH UPGRADEABLE FOR EASY FIRMWARE UPDATES IN THE FIELD e CUSTOM PROGRAMMABLE FOR LARGE VOLUME REQUIREMENTS ACCESSORIES BC20 41342 COMMUNICATION CABLE
13. BPM 60 seconds 3 Non Capture 60 seconds 4 Non Function 60 seconds 5 Demand Occasional 60 seconds 6 Demand Frequent 60 seconds 7 AV Sequential 60 seconds 8 Not Used 9 Not Used r 10 Not Used End of Sequence Action Repeat Sequence from Step 1 34 Fetal Maternal Common Configuration for Fetal Maternal Outputs Parameter Setting Maternal ECG 80 BPM Fetal ECG 120 BPM Trigger Mode 2 Minutes KEY 15 Fetal Maternal Sequence Step IUP Simulation Duration 1 Uniform Deceleration 360 seconds 2 Early Deceleration 360 seconds 3 Late Deceleration 360 seconds 4 Uniform Acceleration 360 seconds 5 Not Used e 6 Not Used 7 Not Used 8 Not Used 5 9 Not Used 10 Not Used E End of Sequence Action Repeat Sequence from Step 1 Sick Patient Common Configuration for Sick Patient Outputs Parameter Setting ECG Amplitude 1 0 mV Patient Mode Adult Respiration Resistance 10 35 KEY 16 Sick Patient 1 Sequence Step IUP Simulation Duration Heart Rate 90 BPM ST Elevation 0 1 mV Artifact None 1 Respiration 40 BrPM 60 seconds Temperature 35 C 95 F BP Channel 1 120 80 Heart Rate 100 BPM ST Elevation 0 0 mV Artifact Respiration 2 Respiration 40 BrPM 15 seconds Temperature 40 104 BP Channel 1 120 80 w artifact Heart Rate 120 B
14. Ca CER s HH S HHA 10 77 66 i TM A UNIT OF BC GROUP INTERNATIONAL INC PROGRAMMABLE PATIENT SIMULATOR REMOTE CONTROL WITH TRENDING PSR 2200 MP USER MANUAL BC BIOMEDICAL PSR 2200 MP TABLE OF CONTENTS WARNINGS CAUTIONS NOTICES DESCRIPTION This User Manual covers the following units e PSR 2200 MP WARNING USERS The PSR 2200 MP is for use by skilled technical personnel only WARNING USE The PSR 2200 MP is intended for testing only and should never be used in diagnostics treatment or any other capacity where it would come in contact with a patient WARNING CONNECTIONS All connections to patients must be removed before connecting the DUT to the Patient Simulator and PSR 2200 MP A serious hazard may occur if the patient is connected when testing with the Patient Simulator amp PSR 2200 MP CAUTION MODIFICATIONS The PSR 2200 MP is intended for use within the published specifications Any application beyond these specifications or any unauthorized user modifications may result in hazards or improper operation CAUTION SERVICE The PSR 2200 MP is intended to be serviced only by authorized service personnel Troubleshooting and service procedures should only be performed by qualified technical personnel CAUTION INSPECTION The PSR 2200 MP should be inspected before each use for obvious signs of abuse or wear The PSR 2200 MP should not be used and should
15. LIST SCREEN This screen shows the key names for the 18 programmable keys This gives the user the ability to identify a programmed key by name instead of memorizing key numbers It can be accessed using the a key Kev List 1 MSR 3UBPm Aenea Atrial 10rm v 2 Perf Sine 50 Fetal Suto Smin Several status messages are available to indicate the present state of the system The following is a brief description of the available messages NUM LOCK This is a small graphic overlay located in the upper right corner of the screen that indicates that the remote is in NUM LOCK MODE and any further key entry will activate the user programmed key configuration Mormal Sinus Rh thir 50 BPM 1 0 m Adult ST 00m amp rtf 30 1 0 ohm 3r c S85F KEY NUMBER This is a small graphic overlay located in the lower right corner of the screen that indicates which user programmed key function has been loaded Pacemaker Vyavefor Bur Asynchronous 75 1 0m ST 0 0 Art Mane Pulse 5 0 mv 1 0 me 3r 0C 98 6FlkEv 09 SEQUENCE NUMBER This is a small graphic overlay located in the lower right corner of the screen that indicates which user programmed key sequence is running Normal Sinus Ahs thiha BPM 1 0 m Adult ST Artt none 30 BrPhi 3 0 ohms 37 0 985 Pune Sequence Step SAVE PROGRESS This indicator is shown when a key configuration has been Time until ne
16. PM ST Elevation 0 5 mV Artifact Baseline Wander 3 Respiration 60 BrPM 30 seconds Temperature 40 C 104 F BP Channel 1 120 80 w artifact Heart Rate 140 BPM ST Elevation 0 4 mV Artifact Muscle 4 Respiration 60 BrPM 10 seconds Temperature 40 C 104 F BP Channel 1 120 80 w artifact Heart Rate 180 BPM ST Elevation 0 8 mV Artifact Baseline Wander 5 Respiration 80 BrPM 15 seconds Temperature 40 C 104 F BP Channel 1 120 80 w artifact Heart Rate 140 BPM ST Elevation 0 4 mV Artifact None 6 Respiration 60 BrPM 15 seconds Temperature 40 C 104 F BP Channel 1 120 80 w artifact Heart Rate 100 BPM ST Elevation 0 1 mV Artifact Baseline Wander 7 Respiration 40 BrPM 15 seconds Temperature 37 C 98 6 F BP Channel 1 120 80 Heart Rate 90 BPM ST Elevation 0 1 mV Artifact None 8 Respiration 40 BrPM 15 seconds Temperature 35 C 95 F BP Channel 1 120 80 9 Not Used 10 Not Used End of Sequence Action Repeat Sequence from Step 1 36 NSR Rate Common Configuration for NSR Rate Outputs Parameter Setting ECG Amplitude 1 0 mV Patient Mode Adult ST Segment 0 mV ECG Artifact None Respiration 30 BrPM Respiration Resistance 10 Temperature 37 0 C 98 6 F BP Channel Settings 120 80 KEY 17 NSR Rate Ramp Sequence Step ECG Respiration Duration 1 30 BPM 15 BrPM 15 seconds 2 40 BPM 20 BrPM 15 seconds 3 45 BPM
17. al Fibrillation Course 60 seconds 2 Atrial Fibrillation Fine 60 seconds 3 Atrial Flutter 60 seconds 4 Atrial Tachycardia 60 seconds 5 Paroxysmal Atrial Tachycardia 60 seconds 6 Supraventricular Tachycardia 60 seconds 7 Sinus Arrhythmia 60 seconds 8 Missed Beat 60 seconds 9 Nodal Rhythm 60 seconds 10 Not Used End of Sequence Action Repeat Sequence from Step 1 KEY 12 Ventricular Sequence Step Ventricular Arrhythmia Waveform Duration 1 Pair of PVCs Auto 60 seconds 2 Run of 5 PVCs Auto 60 seconds 3 Run of 11 PVCs Auto 60 seconds 4 6 PVCs per Minute 60 seconds 5 12 PVCs per Minute 60 seconds 6 24 PVCs per Minute 60 seconds 7 Frequent Multifocal PVCs 60 seconds 8 Bigeminy 60 seconds 9 Trigeminy 60 seconds 10 Ventricular Tachycardia 60 seconds End of Sequence Action Repeat Sequence from Step 1 33 KEY 13 Conduction Sequence Step Conduction Arrhythmia Waveform Duration 1 15 Degree Heart Block 60 seconds 2 2 Degree Heart Block 60 seconds 3 3 Degree Heart Block 60 seconds 4 Right Bundle Branch Block 60 seconds 5 Left Bundle Branch Block 60 seconds 6 Not Used 7 Not Used 8 9 Not Used a 10 Not Used End of Sequence Action Repeat Sequence from Step 1 KEY 14 Pacemaker Sequence Step Pacemaker Waveform Duration 1 Atrial 80 BPM 60 seconds 2 Asynchronous 75
18. ct a key to configure m Use this section to select a key as single function or sequence and to name the key E 11118 E ES ES ED E List 1 Static 0 mmHg Single Function Sequence Name NSR 80 Fm 2 static mmHg Read sug to Cancel At End of 3 Staic 0 mmHg Remote ERR Changes Sequence 4 Static 0 mmHg z Edit Key Load Key Save Key Name List Config File Config File uat alt z Current Key Config File ee Arrhythmias Pacemaker No File Loaded Remote Control Info E 7 Model Number Serial Number Firmware Performance d ona P5R 2200 002 pT7348MPB Read Idle Com2 12 28 2006 7 45 Model Identification of remote Task Progress Indicator Status message TodaysDate s Date Current Time Time a ESSE r Kev Information E History of key configuration files Com Port being used 12 5 Use the buttons 1 18 to select a programmable remote key The selected key will be depressed as key 1 is shown When a key is selected the right half of the screen changes to show the configuration of that key LIST This key is used to view edit the Keynames Key Information This box allows the user to select whether a key will Single Function C Sequence Name Key 1 perform a single function or run a sequence of functions
19. es Edit Key Load Key Save Key Name List Config File Config File Current Key Contig File No File Loaded Y Read Remote This button is used to read the current settings in the remote Download To Remote This button is used to update the remote with the key configurations shown on the screen Cancel Changes This button cancels any changes that have been made to the selected key configuration Once a new key is selected the changes cannot be canceled Edit Key Name List This button is used to show the Keyname list window which shows a list of all of the Keynames Load Key Config File This button is used to open a key configuration file that has been saved on the computer As files are opened they are added to the Current Key Config File history for quick future reference If changes have been made to an open file you will be prompted to save them before loading a new file Save Key Config File This button is used to save the current key settings to a file on the computer Current Key Config File This is a listing of the previous config files that have been opened Selecting a file from the list will cause it to open If changes have been made to an open file you will be prompted to save them before loading a new file 15 1151 Key Name Configuration The Keyname List is a quick way to view and Key Key 8 change all of the Keynames By selecting a Ke9 Keyname the right hand sectio
20. ey Name List list 17 CONTROLLING A PATIENT SIMULATOR To control a patient simulator the remote control is first plugged into the AUX connector of the simulator PRE DEFINED FUNCTIONS A fixed function can be loaded by pressing the desired AAAA key To make adjustments to the output selections and d can be used to select and 23232323 modify output tings When the desired output is aaa selected the D key is used to send the configuration to the Patient Simulator Any changes made on the remote will be immediately made on the Patient Simulator USER PROGRAMMABLE FUNCTIONS User programmable functions are accessed 3 To select a pre programmed output simply press the number of the output while in NUM through the NUM LOCK MODE This mode is set by pressing the a key NOTE The NUM LOCK MODE is identified by the NUM icon in the upper right corner of the screen LOCK MODE key can be used to show the list of Keynames that correspond to the user programmable keys With the List Mode the user no longer has to remember which key number corresponds to which Output Mode The key number can be named and the name is viewed through the Key List Mode The Yes are used to select the desired Output Mode and the De key is used to activate that output When a user defined key is loaded a small icon will appear in the lower right corner to identify which key number is loaded Furt
21. her modifications can be made to the simulator output by exiting the NUM LOCK MODE and using the D E b keys to select and modify output parameters When the desired output the DL is used to send the configuration to the Patient Simulator Any changes made on the remote will be immediately made on the Patient Simulator PATIENT SIMULATOR MODE The PATIENT SIMULATOR OUTPUT MODE ECG Arrhythmia Pacemaker Performance Fetal Maternal or Cardiac can be selected easily by pressing the A key to select the Operating Mode Menu with the current operating mode selected The ee Yes are used to select the desired Operating Mode and the A or A keys are used to activate the new Output Mode POWER To turn the remote control off hold the A key for 3 seconds SPECIAL CONFIGURATIONS AVAILABLE The PSR 2200 MP is a unique and extremely versatile instrument capable of many different configurations This capability allows for custom configurations for our large volume customers who desire a dedicated and functionally unique remote control for their patient simulator fleet If you have special requirements on a large scale typically 50 units or more please feel free to contact us regarding your needs POWER The PSR 2200 MP is designed for use with a standard 9V Alkaline battery 20 MANUAL REVISIONS Revision Program Revisions Made Rev 01 DT7349MPB Origination Rev02 DT7349MPB Format Updated LIMITED WARRANTY
22. labeled to provide standard outputs The following tables detail the outputs for each of the keys Standard Outputs Key Waveform Normal Sinus Rhythm NSR 80 BPM Tachy Normal Sinus Rhythm 160 BPM Brady Normal Sinus Rhythm 30 BPM Asyst Ventricular Arrhthmias Asystole Supraventricular Arrhythmias A Flutter Atrial Flutter Supraventricular Arrhythmias A Fib Atrial Finrillation Coarse V Fib Supraventricular Arrhythmias Ventricular Fibrillation Coarse Ventricular Arrhythmias iilud Ventricular Tachycardia Z ia iom PVC2 2177 Common Configuration for Standard Outputs Parameter Setting ECG Amplitude 1 0 mV Patient Mode Adult ST Segment 0 mV ECG Artifact None Respiration 30 BrPM Respiration Resistance 10 Temperature 37 C 98 6 F BP Channel Settings 0 mmHg 23 APPENDIX PRE PROGRAMMED OUTPUTS The PSR 2200 MP comes with a pre programmed set of sequence data already assigned to specific keys as listed below Performance Waveforms Common Configuration for Performance Outputs Parameter Setting ECG Amplitude 1 0 mV Temperature 37 0 C 98 6 F BP Channel Settings Not Active KEY 1 Square Triangular Waves Sequence Step Waveform Duration 1 Square Wave 9 0 125 Hz 10 seconds 2 Square Wave 9 2 000 Hz 10 seconds 3 Triangle Wave 2 00
23. n of the NSR 30Bpm 000 configuration Pace Atrial 10m screen will be updated with that key s Save Cancel Save This button is used to accept any changes made to the Keynames and the close the Keyname screen Cancel This button is used to close the Keyname screen without saving any Keyname changes that were made NOTE Keynames are restricted to 20 characters 16 Output Configuration Arrhythmias Group Premature m Waveform Atrial PAC Auto m ECG ada ST Elevation ECG Artifact 0 0 mv 1 None Respiration Rate Respiration Amplitude 30 ohms Temperature 370 98 6 F Blood Pressure Dutput Selection Artifact 1 2 coms e 3 acom E 4 com E ES Arrhythmias Pace Fetal Cardiac Performance Meise yer File Menu This section shows the Patient Simulator configuration for the selected key The buttons at the bottom select the Output Mode The dropdown lists select the setting for each parameter available in the selected output mode This menu allows you to load a key configuration file save a File Edit About Load Key Config File key configuration file clear the loaded file list history or exit Save Key Config File Clear Key Config File History the program Exit Edit Menu The edit menu provides another way to access the Keyname File Edit About E Edit K
24. peat Sequence from Step 1 26 Blood Pressure Common Configuration for Blood Pressure Outputs Parameter Setting ECG Waveform iue M ECG Amplitude 1 0 mV Patient Mode Adult ST Segment 0 mV ECG Artifact None Respiration 30 BrPM Respiration Resistance 10 Temperature 37 0 C 98 6 F KEY 5 Blood Pressure Sequence Step BP Channels Waveform Duration 1 All Static 0 mmHg 10 seconds 2 BP1 BP2 BP3 BP4 Static 80 50 20 20 10 seconds 3 BP1 BP2 BP3 BP4 Static 160 100 40 40 10 seconds 4 BPI BPZ BPS BPA Ed d 10 seconds 5 BP1 BP2 BP3 BP4 Static 320 200 80 80 10 seconds 6 BP1 BP2 BP3IBP4 ri en m 10 seconds 7 BP1 BP2 BP3 BP4 Static 10 10 5 5 10 seconds 8 BP1 BP2 BP3 BP4 Not Used 9 BP1 BP2 BP3 BP4 Not Used 10 BP1 BP2 BP3 BP4 Not Used End of Sequence Action Repeat Sequence from Step 1 27 Respiration Common Configuration for Respiration Outputs Parameter Setting ECG Waveform iue M ECG Amplitude 1 0 mV Patient Mode Adult ST Segment 0 mV ECG Artifact None Respiration Resistance Temperature 37 0 C 98 6 F BP Channel Settings 0 mmHg KEY 6 Respiration Sequence Step Respiration Rate Duration 1 0 BrPM Apnea 10 seconds 2 15 BrPM 10 seconds 3 20 BrPM 10 seconds 4 30 BrPM 10 seconds 5 40 BrPM 10 seconds 6 60 BrPM
25. vailable display modes are ECG Output Blood Pressure Output and Operating Mode These are 10 fixed function keys that configure the Patient Simulator for a pre defined output configuration NOTE The default outputs can be adjusted using the PSR 2200 MP keys described above See the CONTROLLING A PATIENT SIMULATOR Section on page 20 for more details See APPENDIX A STANDARD CONFIGURATION OUTPUTS for a description of the default outputs of these keys These are user defined keys that are accessed via the NUM LOCK MODE Num Lock is toggled by pressing the 20 NOTE The PSR 2200 MP has been pre configured with a default set of NUM LOCK programmed outputs Each of these is a programmed sequence See the TRENDING CAPABILITIES Section on page 16 for more details See APPENDIX B PRE PROGRAMMED OUTPUTS fora listing of these pre programmed keys a This key displays the user defined keys by Keyname Keynames are programmable via the computer interface SCREENS MAIN SCREENS There are three main screens ECG Blood Pressure and Operating Mode The available screens can be toggled using ECG SCREEN The ECG screen shows the current operating mode of the Patient Simulator as well as the parameters that are available for that mode Operating modes available to the remote control are ECG Arrhythmias Pacemaker Performance Fetal Maternal and Cardiac Output Normal Sinus
26. xt step successfully sent from the PC During this process the key configuration data is being stored to non volatile memory in the remote control Normal Sinus Rhsthm saving Key Contig 37 0 96 6 F LOW BATTERY This message indicates that the batteries are low and should be replaced Normal Sinus Rhythm z LOW BATTERY 9 Life Remaining C SSBF COMMUNICATION ERROR This message indicates that the simulator did not acknowledge a command that was sent to it If the cables are connected properly cycle power on the PSR 2200 MP and the Patient Simulator and try the command again Normal Sinus Rhythm THE COMMAND 1185 ACCEPTED EY THE SIMULATOR CHECK COMECTIOM AND TRY a c 96 6 F SETUP The SETUP MODE allows the user to adjust the configuration of the remote The Setup screen can be entered using the 2 and then selecting the Remote Control Setup item from the Operating Mode list The parameters can be changed by using Bq keys to highlight the desired line and As to toggle the available options The Setup screen can be exited using either the ca or A keys The following is a breakdown of the parameters available in the configuration of the unit Remote Control Setup Auto Off Timer tina Backli sht Timer Seca a Battery Life qz LCD Contrast 15 Software and their available options System Setup Configuration