Home

Quick Guide - MoblVac® portable wound care pump with

image

Contents

1. MoblVac This unit is to be used by trained medical personnel only This guide is to be used as a quick reference for the operator Please refer to the operation manual supplied wih the unit for complete operating and usage instructions D Yes you can CONTINUOUS THERAPY MODE Press Power button to begin Green LED will illuminate and screen will power up Press Continuous button An audible noise will be heard as the pump begins to apply negative pressure Continue to next page O P N 1176102 2 CONTINUOUS THERAPY MODE CONTINUOUS VACUUM MODE mmHg 3 Press Increase and set pressure to prescribed vacuum level P N 1176102 3 INTERMITTENT THERAPY MODE Press Power button to begin Green LED will illuminate and screen will power up Thne press Intermittent button P N 1176102 Continue to next page 4 INTERMITTENT THERAPY MODE Kerreg Press increase decrease buttons to set the desired On timing Press Enter Repeat for desired 2 Off timing interval Press Enter when done Pump will begin to apply negative pressure P N 1176102 Continue to next page 5 INTERMITTENT THERAPY MODE 3 Press Increase and set pressure to prescribed vacuum level P N 1176102 6 O OPTIONS SLEEP MODE ILLUMINATION Once the unit is set to the proper pressure an
2. 769600 MoblVac Portable Wound Care Pump Dressing Kits Tri Fold packaging with instructions for use 769812 TruSeal Link Woundcare Kit Value 769813 TruSeal Link Woundcare Kit Economy 769814 TruSeal Link Woundcare Kit Medium Channel 769815 TruSeal Link Woundcare Kit Small Round 769816 TruSeal Link Woundcare Kit X Large Round 769804 TruSeal Link Seal Kit MoblVac Accessories 769703 Collection Canister with Solidifier 769703 NS Collection Canister without Solidifier 769605 Replacement Power Supply 769700 MoblVac Premium Transport Bag 769606 Pole Clamp P N 1176102 14 O Monitor patient for excessive bleeding which may result in serious injury or death If sudden or increased bleeding is observed immediately stop therapy and seek medical attention Do not use this or any electrical device in an explosive or flammable environment or in the presence of flammable anesthetics Read understand and follow the operation manual including the clinical considerations guidelines section for safe use The user manual can be found at www MoblVacNPWT com P N 1176102 15 CONTACT US Clinical Technical Hotline 866 985 NPWT 6798 www MoblvacNPWT com info_icc invacare com Invacare Continuing Care Inc USA 2011 Invacare Continuing Care Inc All One Invacare Way rights reserved Republication duplication or Elyria Ohio USA modification in whole or in part is prohibi
3. ank and Flashing Battery nearly depleted Plug in immediately Assuming fully charged battery n P N 1176102 H ALARMS NOTE To silence alarms for leak or canister press the Silence button LEAK ALARM If the system detects a leak an audible alarm will sound the pump will pulse frequently and the display will flash this message LEAK ALARM CORRECTIVE ACTION Check dressing for hissing sound Seal edges with tape or additional film dressing Pinch paste around drain tube Ensure tubing is firmly connected to canister Press firmly on canister in a downward motion PAUSE REMINDER ALARM If the unit is left in pause mode the alarm will sound three times every five minutes to remind the user to restart the unit To restart unit press the Run button P N 1176102 12 O ALARMS CANISTER ALARM When the canister becomes full negative pressure will cease an audible alarm will sound and the display will flash this message CANISTER ALARM CORRECTIVE ACTION Replace full canister and press Run to resume therapy Ensure unit is upright NOTE You cannot silence this alarm until plugged into wall power PAUSE REMINDER ALARM When the unit has approximately 10 minutes of battery operation remaining an audible alarm will sound CORRECTIVE ACTION Plug unit into wall power P N 1176102 13 RE ORDER PART NUMBERS MoblVac Wound Care Pump
4. d is operating normally after approximately five minutes the display will become black This feature is intended to preserve battery life Green LED indicates unit is OR Press any of the bottom four buttons to illuminate display P N 1176102 7 OPTIONS NOTE From the power up screen press Options button to get Options screen TO TURN SLEEP MODE OFF Press the Sleep Off button This will turn off the sleep mode and the screen will stay illuminated Then press Return to go back to therapy operating mode It is recommended to only use this feature when plugged into wall power as it will deplete the battery faster 1176102 8 OPTIONS TO ENGAGE LOCKOUT MODE Press the Lockout button from the options menu to lock unit This will disable the keypad and protect the settings from accidental button presses The lockout icon will appear TO DISENGAGE LOCKOUT MODE Press and hold the Hold to Unlock button and then simultaneously press the Unlock button that will appear on screen This action will unlock the keypad P N 1176102 9 SYMBOLS SYMBOLS LEGEND Power On Off T Lockout Mode Active Unit Connected to Wall Power P N 1176102 10 O e SYMBOLS SYMBOLS LEGEND Battery Level Indicator Green Battery Charged Yellow Battery Partially Charged Red Battery Needs Charging Bl
5. ted 44036 2125 without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by licensed to Invacare Corporation or its subsidiaries unless otherwise noted Manufactured by Ohio Medical Corporation Yes you can P N 1176102 RevA 12 11 16