Home
        Quick Guide  - MoblVac® portable wound care pump with
         Contents
1.           MoblVac       This unit is to be used by trained medical personnel only   This guide is to be used as a quick reference for the operator   Please refer to the operation manual supplied wih the unit for  complete operating and usage instructions     D    Yes  you can           CONTINUOUS THERAPY MODE            Press    Power    button to begin  Green LED  will illuminate and screen will power up     Press    Continuous    button  An audible noise will be  heard as the pump begins to apply negative pressure     Continue to next page O  P N 1176102 2                 CONTINUOUS THERAPY MODE    CONTINUOUS VACUUM MODE    mmHg       3 Press    Increase    and set pressure    to prescribed vacuum level     P N 1176102 3             INTERMITTENT THERAPY MODE       Press  Power  button to begin  Green LED    will illuminate and screen will power up   Thne press    Intermittent    button           P N 1176102 Continue to next page       4              INTERMITTENT THERAPY MODE          Kerreg    Press increase decrease buttons to set the desired     On    timing  Press    Enter     Repeat for desired  2  Off  timing interval  Press    Enter    when done   Pump will begin to apply negative pressure              P N 1176102 Continue to next page 5       INTERMITTENT THERAPY MODE       3 Press    Increase    and set pressure    to prescribed vacuum level     P N 1176102 6 O                   OPTIONS       SLEEP MODE ILLUMINATION    Once the unit is set to the proper pressure  an
2.   769600 MoblVac   Portable Wound Care Pump    Dressing Kits   Tri Fold packaging with instructions for use    769812 TruSeal    Link Woundcare Kit  Value    769813 TruSeal    Link Woundcare Kit  Economy   769814 TruSeal    Link Woundcare Kit  Medium Channel   769815 TruSeal    Link Woundcare Kit  Small Round   769816 TruSeal    Link Woundcare Kit  X Large Round   769804 TruSeal    Link Seal Kit    MoblVac  Accessories    769703 Collection Canister with Solidifier  769703 NS Collection Canister without Solidifier  769605 Replacement Power Supply   769700 MoblVac   Premium Transport Bag  769606 Pole Clamp    P N 1176102 14 O                Monitor patient for excessive bleeding  which may  result in serious injury or death   If sudden or increased bleeding is observed     immediately stop therapy and seek medical attention     Do not use this or any electrical device in an explosive  or flammable environment or in the presence of  flammable anesthetics     Read  understand and follow the operation manual   including the clinical considerations guidelines section  for safe use  The user manual can be found at   www MoblVacNPWT com        P N 1176102 15             CONTACT US       Clinical Technical Hotline  866 985 NPWT  6798     www MoblvacNPWT com info_icc invacare com    Invacare Continuing Care  Inc     USA    2011 Invacare Continuing Care Inc  All  One Invacare Way rights reserved  Republication  duplication or  Elyria  Ohio USA modification in whole or in part is prohibi
3. ank and Flashing   Battery nearly depleted  Plug in immediately      Assuming fully charged battery     n  P N 1176102 H             ALARMS    NOTE  To silence alarms for leak or canister  press the    Silence    button   LEAK ALARM    If the system detects a leak  an audible alarm will sound   the pump will pulse frequently  and the display will flash  this message           LEAK ALARM       CORRECTIVE ACTION       Check dressing for    hissing    sound   Seal edges with tape or additional film dressing  Pinch paste around drain tube   Ensure tubing is firmly connected to canister  Press firmly on canister in a downward motion    PAUSE REMINDER ALARM    If the unit is left in pause mode  the alarm will sound   three times every five minutes to remind the user to   restart the unit  To restart unit  press the  Run  button    P N 1176102 12 O                   ALARMS       CANISTER ALARM    When the canister becomes full  negative pressure will  cease  an audible alarm will sound  and the display will  flash this message          CANISTER ALARM       CORRECTIVE ACTION    Replace full canister and press  Run  to resume therapy    Ensure unit is upright    NOTE  You cannot silence this alarm until plugged into wall power     PAUSE REMINDER ALARM    When the unit has approximately 10 minutes of battery  operation remaining  an audible alarm will sound   CORRECTIVE ACTION     Plug unit into wall power    P N 1176102 13          RE ORDER PART NUMBERS       MoblVac  Wound Care Pump 
4. d is operating normally  after approximately  five minutes  the display will become black  This  feature is intended to preserve battery life        Green LED indicates unit is       OR    Press any of the bottom four buttons to  illuminate display              P N 1176102 7       OPTIONS    NOTE  From the power up screen  press    Options    button to get    Options    screen     TO TURN SLEEP MODE OFF                            Press the    Sleep Off     button  This will turn off the sleep   mode and the screen will stay illuminated  Then press      Return    to go back to therapy operating mode  It is   recommended to only use this feature when plugged into   wall power as it will deplete the battery faster             1176102 8            OPTIONS       TO ENGAGE LOCKOUT MODE    Press the    Lockout    button from the options menu to lock  unit  This will disable the keypad and protect the settings  from accidental button presses  The lockout icon will appear     TO DISENGAGE LOCKOUT MODE    Press and hold the    Hold to Unlock    button and then  simultaneously press the    Unlock    button that will appear  on screen  This action will unlock the keypad        P N 1176102 9       SYMBOLS    SYMBOLS LEGEND    Power On Off    T Lockout Mode Active     Unit Connected to  Wall Power    P N 1176102 10 O                   e SYMBOLS    SYMBOLS LEGEND    Battery Level Indicator    Green   Battery Charged    Yellow   Battery Partially Charged    Red   Battery Needs Charging    Bl
5. ted  44036 2125 without prior written permission from    Invacare  Trademarks are identified by      and      All trademarks are owned by       licensed to Invacare Corporation or its  subsidiaries unless otherwise noted   Manufactured by Ohio Medical Corporation            Yes  you can      P N 1176102 RevA  12 11 16          
    