Digi-Sense TC9000 Quick Start Guide

image

Contents

1. the Alarm Action Display will remain illuminated The alarm and on screen message will not clear automatically even if the system is no longer in an alarm situation AUTO RESET mode Pressing ALARM once will silence the audible alarm and clear the on screen alarm message If the alarm situation is still present the Alarm Action Display will remain illuminated If the system leaves an alarm situation the system will automatically silence the alarm and clear the on screen alarm message 4 SELECT Button Pressing SELECT once will allow you to cycle through user configurable control Set Points The Set Point selected will be underlined Use the UP and DOWN arrow keys to change the value Quick Start Guide TC9000 Advanced PID and On Off Temperature Controller Models 89800 01 and 89800 02 Getting Started a TC9000 D D l G l a S N S E 2 Advanced Thermocouple Controller Heat Cool Tune 1 2 Front 5 MENU Button The MENU button provides access to all user configurable setup parameters of the temperature controller Pressing this key once will scroll through parameter options Pressing and holding this key will exit to the home screen saving any changes made up to that point 6 UP DOWN LEFT Arrow Buttons The UP and DOWN arrow buttons will increase or decrease the value of the Set Point selected underlined Pressing the UP or DOWN arrow keys will increase or decrease numeri
2. D DIGI SENSE Quick Start Guide Digi Sense TC9000 Advanced PID and On Off Temperature Controller with Thermocouple Input Models 89800 01 and 89800 02 Advanced Thermocouple Controller THE STANDARD IN PRECISION MEASUREMENT 1 CE Quick Start Guide TC9000 Advanced PID and On Off Temperature Controller Models 89800 01 and 89800 02 Getting Started a TC9000 D D G l S E N S E Advanced Thermocouple Controller Heat Cool Tune 1 2 Front 1 RUN STOP Button Pressing RUN STOP once will start the control process if the temperature controller is stopped or stop the control process if the temperature controller is the run mode If the temperature controller is running Heat and Cool on screen indicators will illuminate appropriately with the mode selected in the setup menu The Control Action selection is in the Advance Menu Gateway setup 2 TUNE Button Pressing TUNE once will start the AUTO TUNE cycle AUTO TUNING must be enabled in the setup menu for this key to function 3 ALARM Button In an ALARM situation the display will indicate either WARNING or ERROR with corresponding warning or error A WARNING will not stop the control process An ERROR will stop the control process MANUAL RESET mode Pressing ALARM once will silence the audible alarm and clear the on screen alarm message If the alarm situation is still present
3. bY Thermocouple input accepts types J K N R S T B and E with mini connector Quick Start Guide TC9000 Advanced PID and On Off Temperature Controller Models 89800 01 and 89800 02 Setup and Operation Initial Setup Install controller in a safe operating area Plug the heater or cooler sold separately into the output connector located on the back of the controller Connect the thermocouple sensor input connector located on the back of the controller Place the ferrite clip over the lead wire of the thermocouple sensor See page 31 in the User Manual for reference picture of installation of ferrite Plug supplied AC cord into the IEC power connector located on the back of the controller Basic Operation Setup Turn power switch ON located on the back of control Follow the instructions on the welcome screen Press SELECT key to read a brief description of each key on the front of control Press the MENU key to skip the instructions and enter into the main operation screen Press the SELECT key to make a user editable field active A line will appear under the field when the field is active for editing Use the UP DOWN arrow keys to adjust the value that is active in a user editable field Enter the user configurable setup by pressing the MENU key from the system status screen Use the MENU key to advance through each menu setting TC9000 control mode is set at the factory for PID operation with a type J t
4. cal entries by the least significant digit i e 00 0 to 00 1 1 to 2 Pressing and holding UP or DOWN arrow keys will increase or decrease numerical entries using an acceleration factor For every ten units the rate of acceleration will increase by a factor of ten Pressing and holding UP and DOWN arrow keys will increase or decrease text entries without an acceleration factor The LEFT arrow button allows you move backwards through the GENERAL SETUP MENU GSM and ADVANCED SETUP MENU ASM While in the ASM you can move backwards to the first ASM screen but cannot back into the GSM To exit to the main screen from either menu press and hold the MENU button 7 HEAT COOL AND TUNE Indicators When any of these modes are active it will have a block indicator on the display showing it is active Example When the controller is in the heat mode and is applying power to the heater output there will be an indicator block on the display next to Heat to show the heater output is active Quick Start Guide TC9000 Advanced PID and On Off Temperature Controller Models 89800 01 and 89800 02 IEC 60320 C19 230 VOLT 5 15R 115VAC Shown in image Use only 250V fuses 15 Amp Rating T C Universal Mint Plug BACK 1 IEC power cord connection see page 32 in the User Manual for additional cords Fuse Heater Cooler output see pages 33 34 in the User Manual for optional cord adapters Power switch Grid support bracket o oe A m
5. hermocouple input sensor If different control mode is desired reference the User Manual for setup instructions All changed settings will be retained in memory when returning to the System Status screen Use the screen flow charts on pages 29 30 of the User Manual to have a visual of the controls menu layout Auto Tune Operation Setup Set up your process as noted in the initial setup Verify that the Auto Tune feature is enabled in the menu settings From the main operation screen set the Set Point temperature Press the TUNE button and the indicators showing Tune and Heat will be illuminated on display The Set Point value can not be altered after the Tune process has started The value is locked until the Tune process is complete or aborted by the user Stopping the Tune operation prior to it finishing will cause the PID settings to be returned to the factory default values PID values will be saved in nonvolatile memory For complete information reference the User Manual F A DT oii 7 Cole DAVIS lt Cole Parmer HEU Delivering Solutions You Trust onan arke aenn Toll Free 1 800 323 4340 Toll Free 1 800 358 5525 Phone 1 847 549 7600 Phone 1 847 327 2000 Fax 1 847 247 2929 Fax 1 847 327 2700 ColeParmer com Digi Sense Davis com Digi Sense 1065DGMAN_TC9000_b 08 2014 Rev 1