Home

I/P Transducer - Sullivan & Sons, Inc.

image

Contents

1. Division 1 Groups A B C D T6 60 C Max T2000 Part Matrix 2K E 1 00 Electrical Port N 1 2 NPT Conduit Pneumatic Ports Manifold Mount Agency Approval FMICSA FM Natural Gas Approval for US and Canada Electrical Input Bottom O Ring Ports Direct Acting Reverse Acting Pneumatic Output Full Range Split Range High Split Range Low Dust Ignition Proof Class Il Ill Division 1 Groups E FG T6 Pressure Ranges 60 C Max PSIG BAR CE Conduit Connector Only EN 50081 1 Residential commercial amp 0 5 0 0 3 light industry EN 50082 2 Heavy Industrial 0 15 0 1 0 3 15 0 2 1 0 1 17 0 07 1 2 Maximum supply for Terminal Block I P Transducer E P Transducer 0 30 0 2 1 oe ranges S N C Signal 6 30 0 4 2 1 Signal Power Supply 3 97 0 2 1 9 Signal Common rated NRTL Listed or Certified conduit seal 0 60 0 4 1 100 0 100 0 6 9 It is mandatory for the user to install a suitably 0 120 0 8 3 Maximum supply for these pressure ranges is 140 psig Specials OO None E E ns and Switch Positions Switch 3 Split Low Switch A 3 OFF Full Split High 4 5 f tage Split Low Reverse nput E P Full Acting 4 5 Current Input I P 8 Split Low Split High Split High belgas net Mounting Options Mounting Method Explosion Proof E Model In Line Yes Direct Mounting Side or Bottom Holes Panel Bracket Accessory Valve
2. SF 04IMF 1 2 Iron w nipple Epa als E 4 i alled approx 1 16 oz of d 1 5 oz of compound is used QD Part Number Description SC 4 4 oz Sealing Compound SC 8 8 oz Sealing Compound FP 4 4 oz Packing Fiber Larger quantities of fiber and compound available upon request belgas net Supply Pressure Effect Vibration Effect Mounting Position Effect RFI EMI CE Compliant _ Belegs Accessories Part Number Panel Mounting Kit 010 135 000 Valve Mounting Kit 010 134 000 2 Pipe Mounting Kit Valve Mounting Kit is required 010 143 000 DIN Rail Adapter 010 115 000 Manifold Adapter Kit 971 158 000 Filter Kit 60 microns 010 139 000 Pressure Gauge Kit 15 psig 1 BAR 010 138 000 Pressure Gauge Kit 30 psig 2 1 BAR 010 138 001 Pressure Gauge Kit 60 psig 4 1 BAR 010 138 002 010 138 003 Pressure Gauge Kit 160 psig 11 BAR T2000 Specifications includes effects of hysteresis dead band and repeatability Electrical Switch Selectable 4 20mA 0 5 1 5 1 9 1 10 or 0 10VDC Connections 1 2 NPT or 20mm Conduit Power Supply 5 28VDC with voltage inputs only Direct Reverse Acting Switch Selectable Pneumatic Inputs 0 5 0 15 3 15 1 17 0 30 6 30 3 27 0 60 0 100 or 120 B 0 0 1 0 0 3 0 1 0 0 2 1 0 0 07 1 2 0 2 1 0 4 2 1 0 2 1 9 0 4 1 0 6 9 0 8 3 AR 1 4 NPT BSPT or BSPP threads pokes vipueiQutpuy Bottom ported for Manifold Mounting Exp
3. inert Gases Explosion Proof Class Div 1 Groups A B C amp D T6 Ta 60 C Dust Ignition Proof Classes Il amp Ill Div 1 Groups E F amp G T6 Ta 60 C TYPE 4X IP 66 intrinsically Safe Class Il amp Ill Div 1 Groups A B C D E F amp G T4 Ta 60 C TYPE 4X IP 66 Non Incendive Class Div 2 Groups A B C amp D T4 Ta 60 C Suitable Class Il Div 2 Groups F amp G T4 Ta 60 C Suitable Class Ill Div 2 T4 Ta 60 C Type 4X IP 66 Entity Parameters I P Vmax SOV Iwa 200 MA Pux TW Ci O Li O E P V 30V Iux 100 MA Pus 0O78 W Ci O Li O E Model with G approval Explosion Proof United States and Canada For use with natural gas or other non inert gases as APPROVED a process medium up to a maximum input pressure of 140 PSI when installed with suitable NRTL listed D certified or approved conduit seal installed at the enclosure Explosion Proof Class Div 1 Groups A B C amp D T6 Ta 60 C Dust Ignition Proof Classes II amp Ill Div 1 Groups E F amp G T6 Ta 60 C Ex NEMA 4X IP 66 CANADIAN STANDARD ASSOCIATION Drawings and E Model with F approval Explosion Proof Intrinsically Safe dimensions are for Certified to Two Standards reference only Certified to CLASS 2258 04 PROCESS CONTROL EQUIPMENT Class l Div 1 amp 2 Groups A B C D Class Il Div 1 Groups E F and G Div 2 Groups F and G Class Ill Rated 28Vdc 8mA T6 E
4. the easiest way to recalibrate would be to change the switch se tch to split range low eld Selectable Features Onboard switches allow the t T2000EX for any of several el calibration may be nec a Direct Reverse Acting Direct Acting transducers regulate to their mini mum output when supplied with minimum input maximum out with maximum in Reverse Acting transducers regulate to their maximum output at minimum input Split Ranging High amp Low The T2000EX can be configured to regulate either half top or bottom of it s normal output range when supplied with it s normal full ranging electri cal input For example a O 10V 0 30 PSIG unit set to split range low will regulate O 15 PSIG O 10V It will regulate 15 30 PSIG O 10V if set to split range high Hazardous Area amp Usage Classification F model Dual Listing of FM CSA for following approvals Explosion Proof Class Division 1 Groups A B C D T6 60 C Max Dust Ignition Proof Class Il Ill Division 1 Groups E F G T6 60 C Max Intrinsic Safety FM CSA Class Il Ill Division 1 Groups A B C D E F G T4 60 C Max Non incendive Class Division 2 Groups A B C D T4 60 C Max Suitable for use in Class II Ill Division 2 Groups F G T4 60 C Max Environmental rating TYPE 4X IP66 G model Listing of FM for using Natural Gas as a process medium in US and Canada for following approvals Explosion Proof Class
5. Bracket Supplied Pipe Bracket Accessory DIN Rail Bracket Accessory Manifold Plate Accessory Mounting The Type 2000 can be mounted in line or directly to a panel via mounting holes located in the side and bottom of the unit In addition the S model includes a panel mounting bracket while the E model includes a valve mountingQ bracket Kits are available for mounting of either model to panel valve pipe or DIN Rail A custom plate is available for mounting of the bottom ported version to a manifold See Accessories Sealing Fittings for FM approved T2000 EX Transducers Application amp Installation Class I Divisions 1 amp 2 Seals in a Class hazardous location minimize the passage of gases and vapors and prevent the passage of flames from one electrical installation to another through the conduit system Seals are required to be installed within 18 inches on any con duit run entering an enclosure which contains devices that may produce arcs sparks or high temperatures The T2000 Explosion Proof Transducer is available with the seal supplied as a component to be applied at the installation of the system It is mandatory for a suitably rated conduit seal to be installed with the FM approved T2000 EXP Transducer Vertical or Horizontal Seals All seal housings are approx 3 1 2 in laying length and 1 1 2 OD Part Number Description SF 04AMM 1 2 Aluminum SF O4AMF 1 2 Aluminum w nipple SF 04IMM 1 2 Iron
6. T2000 Explosion Proof I P amp E P Transducers e Field selectable inputs and direct reverse split ranging e Multiple input output mounting configurations e Precise reliable performance under extreme conditions of temperature vibration orientation supply pressure changes supply voltage changes RFI EMI humid oil laden media and corrosive surroundings The T2000EX is a robust electronic instrument that regulates an incoming supply pressure down to a precise output pressure which is directly proportional to an electrical control signal The secret to the T2000EX s precise reliable performance under a va riety of demanding environmental conditions is a patented piezo ceramic actuator with many industry wide firsts Applications Chemical amp Petrochemical Industries Petroleum Production Pipeline Transmission e Valve Actuators e Valve Positioners e Relay e Controllers The T2000EX I P and E P transducers utilize closed loop pres sure feedback control for precision pressure output and mini mized effects of temperature supply pressure changes supply voltage changes and mounting angle Supply pressure is reduced by the supply valve to provide an out put pressure which is internally routed to a precision temperature compensated piezo resistive pressure sensor Supply pressure is also routed to an externally removable orifice which provides a re duced pilot pressure to a chamber containing a servo diaphragm and
7. be fine tuned in the field An easily removable cover provides access to the isolated electronics All potentiom eters connections jumpers and switches are clearly marked on the circuit board or on the handy chart located on the inside of the cover The three elements of calibration Gain Zero and Span are described below Consult the T2000EX User s Manual for detailed calibration procedures cautions and instrumentation requirements Gain Damping Adjustment The output response of the T2000EX can be optimized for vary ing downstream volumes by adjusting the system gain of the con trol circuit Adjust the Gain Pot counterclockwise for increased gain clockwise for increased oscillation damping For maximum allowable gain in your application the pot should be turned clock wise until oscillation just disappears Zero amp Span Adjustments The T2000EX contains multi turn Coarse Zero Fine Zero and Span adjustment potentiometers which are clockwise positive Adjustment of either Zero Pot changes the unit s minimum output while the Span Pot changes the maximum output The adjust ments are interactive so it may take iterations to reach the de sired settings Wide Rangeability The T2000EX can be field calibrated to pressure ranges other than the standard ones by combinations of recalibration pressure a range outside its pressure sensor family switched to a 3 15 PSIG but not to 0 30 PS exceed the range of the onboard
8. losion proof only 1 8 27 NPT AIBNPT Ports Gauge 1 8 NPT For 0 5 PSIG 0 3 BAR Through 0 60 PSIG From 5 PSIG 0 3 BAR above maximum output to 100 PSIG maximum Outputs For 0 100 PSIG and 0 120 PSIG Ranges From 5 PSIG 0 3 BAR above maximum output to 140 PSIG maximum si Switch Selectable Full Range or Split Range High or Split Ranging Split Range Low 4 scth maximum 1 9 LPM Range Sensor PSIG BAR PSIG 05 003 5 03 015 010 15 10 315 0 21 0 15 1 0 117 0 07 1 2 15 1 0 e oe 0 60 041 50 35 17 Co gt JI N s i oo 3 R93 RO RO RO RO RO I wl GO Go GO GO GO No 480 Typical Flow 100 PSIG 6 9 BAR in and maximum out 0 100 069 100 69 21 0 120 0 8 3 100 69 21 Typical Flow 140 PSIG 9 7 BAR in and maximum out 3 SCFM 85 LPM 5 PSIG 0 3 BAR above setpoint 0 15 PSIG range unit set at mid range Exhaust Capacity N feb lt Supply Voltage Effect None lt 1 FS 1G 5 1000Hz2 lt 02 FS F 40 to 180 F 40 to 82 C 40 to 200 F 40 to 93 C O lbs 1 35 kg Temperature Effect Storage Temperature Approximate Weight y Ww Type 2000 Explosion Proof Dimensions Agency Approvals Applies only to units ordered with approvals FACTORY MUTUAL E Model with F approval Explosion Proof Intrinsically Safe Not for use with natural gas or other Non
9. nclosure TYPE 4X IP66 Max Ambient Temperature 60 C Entity Parameters I P Vax SOV Iga 2ZOOMA Prax OW Ci OuF Li OuH E P Vuxs SOV Iya 100MA P uax 70 75W Ci 0uF Li 0OuH REGULATED PRESSURE VS FLOW Certified to CLASS 2258 02 PROCESS CONTROL EQUIPMENT PSIG BAR 140 psig supply pressure Rated 28Vdc 8mA T6 Ende A TYPE 4X IF aaO TNT pe 60 4 1 dT dT dT tS Se oa ttt ttt Trt yy 40 28 REGULATED PRESSURE es PTT EET a ttt SCFM 0 2 4 6 8 10 12 14 22 24 LPM 0 57 113 170 227 283 340 397 a i A 623 680 Forwarb Flow It is mandatory for the user to install a suitably rated NRTL Listed or Certified conduit seal belgas net
10. nozzle Pilot pressure is controlled by modulating the gap between the face of a nozzle and an adjacent piezo ceramic ac tuator which is part of a unique patented mechanism The piezo ceramic actuator serves as a control link between elec trical input and pressure output as follows e The input current I P or voltage E P signal is conditioned to provide a normalized control signal directly proportional to the desired pressure output e Simultaneously the output of the pressure sensor is ampli fied and conditioned to produce a feedback signal e The sum of the control signal and the feedback signal pro duce a command signal which is delivered as a DC voltage to the piezo ceramic actuator e As voltage increases the force applied by the actuator increases so as to restrict nozzle bleed and thus increase pilot pressure 1C d pilot pressure applied to the servo diaphragm uses Opening of the supply valve and an increase put pressure until the output feedback signa a A dew point less than 35 F b No particles larger than th c Maximum oil content oi belgas net Belegs a i q hs i j EH iin 1 Note The combined adjustments of Gain Zero and Span are all interac tive It may take several adjustment attempts to accomplish final desired setting Fine Tuning Your Application For optimal performance in your application the calibration of the Type 2000EX can

Download Pdf Manuals

image

Related Search

Related Contents

FAMIS Web Time User Manual - Facilities Net Services  HTC 8310 Cellular Phone  emetteur em10  戸建て向け - me-eco  cp-j-7 - Printemps des Etudes  カラフルでスタイリッシュな生活、はじめよう。  Rexel 803939 folder  Catálogo - chemaide, sa  Infinity Speaker System Total Speaker Solutions User's Manual  L`Ordre des choses-album - Clairière  