IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
Contents
1. OVERLOAD indicator Red The indicator will illuminate when the output power is overload from the unit O BATT CHECK O ON OFF TEST 1 3 BATTY indicator Red The indicator illuminates when the battery is no longer useful and must be replaced 1 4 ON OFF TEST button No matter the UPS is plugged in or not Press the ON OFF TEST CD button till the beep stop to turn on or turn off the UPS It also enables the UPS self test by press the bottom less than 1 second BAZZER STOP 1 5 BUZZER STOP button In back up mode press the bottom about 1 second to C D enable the UPS silence function Rear View 1 6 Outlet Socket 1 7 Communication Port 1 8 Internet Tel Modem Port 1 9 Bypass Outlet U S socket only 1 10 Input Fuse 1 11 AC Input Can be removed if not desired 2 INSTALLATION 2 1 Inspection Inspect the UPS upon receipt The packaging is recyclable save it for reuse or dispose of it properly 2 2 Placement Install the UPS in controlled area with adequate air flowing and free of excessive dust Do not operate the UPS at outdoor area 2 3 Utility Power The input power cord needs to connect the rear inlet socket of the UPS and plug into a socket on the wall Please notice the voltage of utility power should match with the UPS For example the rating voltage of UPS is 110V 220V the input utility power should be the sam
2. condition of LOW BATTERY or OVERLOAD 3 4 Self test function Press the TEST button at LINE mode about 1 second UPS will perform self test procedure automatically 4 1 BACKUP slow alarm When the UPS is working under BACKUP mode the UPS would emit audible alarm The alarm stops when the UPS is return to LINE mode operation Attention The alarm of BACKUP is going to beep every 2 seconds Slow speed beep Attention The UPS provides mute function for the warning When the beeping sound occurs press BUZZER STOP to stop it and press BUZZER STOP again to resume the sound 4 2 LOW BATTERY rapid alarm In the BACKUP mode when the energy of battery becomes to lower level about 20 30 The UPS beeps rapidly until the UPS shuts down from battery exhaustion or returns to LINE mode operation Attention The alarm of the batteries caused by low voltage beeps every 0 5 second Attention The rapid alarm under LOW BATTERY condition cannot be muted 4 3 OVER LOAD continuous alarm When the UPS is working under overload condition the connected loads exceed the maximum rated capacity the UPS will emit continuous alarm to warn an overload condition In order to protect the unit and the loads the UPS will be automatic turn off Please disconnect nonessential devices from UPS to eliminate the overload alarm 5 SOFTWARE AND INTERFACE PORT 5 1 Power Monitoring
3. 0 or 60Hz 10 auto sensing PROTECTION Unit Input Fuse for overload amp short circuit protection Overload Protection UPS automatic shutdown if overload exceeds 105 of nominal at 20 seconds 120 at 10 seconds 130 at 3 seconds Short Circuit UPS output cut off immediately Voltage single phase BATTERY Type Sealed maintenance free lead acid batteries with3 6 years typical lifetime LED Indicators Battery Check Typical Recharge Time 4 hours to 90 of full capacity Back up Time minutes 10 25 15 30 18 33 PC with 15 monitor minutes minutes minutes Protection Automatic self test Over discharge protection short circuit protection by fuse PHYSICAL Net weight Kg Ibs 3 6 7 9 3 7 8 1 3 8 8 3 Dimension mm WxDxH 70 297 195 2 8 11 7 7 7 INTERFACE Dry contact Sends battery low amp power failure signals and receives shutdown signal from computer RS232 Detect battery low Schedule UPS on off AS input output power status display Battery Back Up Slow beeping sound every 4 seconds buzzer can be turn off by pressing buzzer stop button Battery Low Rapid beeping sound every second 105 load Continue beeping sound every 4 seconds Overload Continue beeping sound Overload LED Always On ENVIRONMENT Ambient Operation 3 500 meters max elevation 0 95 humidity non condensing water 0 40 C Audible Noise lt 40dBA 1 meter from surface 2002 March 05 Version 1 0 All right Reserved A
4. LU PrP S Uninterruptible Power System 500VA 650VA 800VA User s Manual IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries WARNING Controlled Environment Intend for installation in a controlled environment CAUTION Do not dispose of batteries in a fire the battery may explode CAUTION Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes It may be toxic CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of batteries Disconnect charging source prior to connecting or disconnecting battery terminals Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing battery replace with same type Do not to addition battery for UPS TABLE OF CONTENTS INTRODUCTION E E EEE T E A A A A IMPORTANT SAFETY INSTRUCTIONS 0 cccccecceeecceeceecaccesnceneeeesceenceeaseesutetasseststeaaeeres Ve PRESENTATION ceniicccetavecica covevinedacdeaSaedusetv
5. Software The UPS MON series software or other power monitoring software is applied standard RS 232 interface to perform monitoring functions and then provides an orderly shutdown of a computer in the event of power failure Moreover UPS MON displays all the diagnostic symptoms on monitor such as Voltage Frequency Battery level and so on The software is available for DOS Windows 3 1x Windows 95 Windows 98 Windows NT V3 5 or later Novell Netware Linux and others Call your dealer for more information on computer OS compatible solutions 5 2 Interface Kits A series of interface kits is available for operation systems that provide UPS monitoring Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating system recognizes The interface cable at UPS side must be connected to REMOTE PORT at computer side can be either COM 1 or COM 2 The other installation instructions and powerful features please refer to READ ME file CAUTION Use only factory supplied or authorized UPS monitoring cable 5 3 The characteristics of computer interface port The computer interface port has the following characteristics The communication port on the back of the UPS may be connected to host computer This port allows the computer to monitor the status of the UPS and control the operation of the UPS in some cases Its major functions normally include some or all of the fol
6. deandvabtedssPsahtesecveeideve Ge siavadwddsvemsevedundousviaee 2 INSTALLATION seer e aar coke aceutscnsettatne cSauve eb A a a a nee meeuaaidven cteseantenceweceaaeuceeac Please read and save this manual Thank you for selecting this uninterruptible power system UPS It provides you with a perfect protection for connected equipment The manual is a guide to install and use the UPS It includes important safety instructions for operation and correct installation of the UPS If you should have any problems with the UPS please refer to this manual before calling customer service 1 PRESENTATION The UPS is a standby uninterruptible power system UPS When utility input is normal the UPS would provide surge protection and energy to charge the internal battery If the utility input is abnormal the UPS can supply AC power to the load immediately 1 Utilizes microprocessor based controls it will minimizes the dependency on hardware Beside this it maximizes system flexibility and optimizes the assurance of reliability 2 Automatic frequency selection to match with utility power 3 Hi grade battery charger to prolong battery s life and fully charge the battery 4 With actual overload protection both in line and battery mode Front View 1 1 POWER indicator Green The indicator will illuminate when the utility input is normal The light becomes flash when working at back up mode v O m pej OVERTOAD 1 2
7. e as 110V 220V 2 4 Connection The employed equipment s power cords such as computer are plugged into the sockets on the rear panel Attention Service personnel installable Attention With the installation the overall leakage current of the UPS connected consumer shall not exceed 3 5mA Attention A block diagram of this unit is attached to the user s manual and to the installation instruction 3 OPERATION 3 1 Switch on When utility input is connected to the UPS press ON button at OFF mode and keep pressing until the beep stops After that connect the electrical cords of the equipment that is going to be used such as computer or monitor with the terminal at the rear panel of UPS Attention This unit is to operate by any individuals with previous training Attention At BACKUP mode UPS can be automatically turned off if none of the connected loads is operating No Load shut down function CAUTION Never connect a laser printer or plotter to the UPS with other computer equipment A laser printer or plotter periodically draws significantly more power than its idle status and may overload the UPS 3 2 Switch off Press the OFF button at LINE or BACKUP modes and keep pressing more than 1 second to turn off the UPS 3 3 Silence When UPS is under BACKUP mode press the BUZZER STOP button about 1 second to silence the audible alarm The function is disabled when UPS is under
8. ll trademarks are property of their respective owners Specifications subject to change without notice 661 EK50 000
9. lowing To broadcast a warning when power fails To close any open file before the battery is exhausted To turn off the UPS Some computers are equipped with a special connector to link with the communication port In addition special plug in cord may be needed Some computers may need special UPS monitoring software Contact your dealer for the details on the various interface Kits APPENDIX A TROUBLESHOOTING UPS cannot turn JON OFF TEST SILENCE button Press the on not pushed or push time too JON OFF TEST SILENCE button LED not light short more than 1 second Load less than 20W at battery Normal condition No load shutdown function is active always at Plug in the power cord battery mode AC FUSE burn out Replace the AC fuse Line voltage too high too low or Normal condition black out PCB failure Replace PCB call for service Back up time too battery not fully charged Recharge the UPS at least 6 short hours PCB failure Replace PCB call for service Buzzer continuous Overload Remove some loads beeping APPENDIX B SPECIFICATIONS MODEL OUTPUT Capacity 500VA 650VA 800VA Bypass Capacity 300VA 300VA 300VA No of sockets Two UPS Sockets and One Bypass Socket Voltage on battery Simulated sine wave at 100V 110V 115V 220V 240V 5 Transfer Time 2 4 milliseconds including detection time 110V 20 15 at line input 110V 115V 20 at line input 220V 25 at line input 240V 15 20 at line input 5