Home

Datasheet - Folksafe

image

Contents

1. ee FOLKSAFE As FS PD1001 E10 Specification Overviews FS PD1001 E10 is a kind of PD Splitter also called POE Splitter supports IEEE802 3af standard supplies power and transmits data to devices which do not support POE power supply such as IP camera The product uses the transformer for isolation design which gives you more stable more secure and Well protects the powered products Bandwidth is 10 100M Mid Span No 4 amp 5and 7 amp 8 cables supply power and End Span No 1 amp 2 and 3 amp 6 cables supply power connections are well supported Output voltage is 12V maximum current is 1 08A Some HD digital cameras do not have POE module which leads to the inconvenience and difficulty on installation However this device can solve the problem of wiring Connect POE switch with PD Splitter people can realize the power supply and data transmission of IP camera directly and timely Typical applications please refer to following picture IP Camera PD Splitter Features 1 Bandwidth 10 100M 2 Input Voltage 37 57V 3 Input port Supports No 4 amp 5 and 7 amp 8 cables supply power and End Span No 1 amp 2 and 3 amp 6 cables supply power connections 4 Output Voltage 12V 5 Output current 1 08A Max 6 Standard Supports IEEE802 3af 7 Isolation protection Using the transformer for isolation design more stable more secure 8 Protection function Overheating protection Short circuit protection overvoltage and over
2. 2 Strip about 2cm s of insulating jacket to let 4 pairs UTP can be seen 3 Separate 4 pairs UTP cable and try to straighten each pair 4 Arrange 8 cables with correct line sequence of EIA TIA 568A or EIA TIA 568B 5 Cut thread residue and leave 1 5cm wire which exposed outside the insulating layer and ensure 8 wires are straight and neat 6 Put 8 wires in RJ 45 connector then press with wire crimpers 7 Repeat above five steps make the other side of UTP cable Then using the cable tester to test whether the cat5e 6 works normally l F LKSAFE Professional UTP Balun Manufacturer Shenzhen Folksafe Technology Co Ltd www folksafe com PoE Switch i 3 a y N ENUM O hoped lesen hh Ww aa Note Ports of this device support Auto MDI MDIX so the different wire sequence at two sides of the cable is allowed when using RJ45 port for transmission After sale Service Once the clients order the device they enjoy free warranty service If the malfunction is caused by its quality itself you can return fully within 15 days replace new devices within 30 days enjoy free warranty within 3 years and enjoy lifetime maintenance The malfunctions and damages cannot enjoy free warranty if they are caused by the factors below 1 All man made damage including operation in abnormal working environment or not in accordance with the instructions and storage failures 2 Users disassemble or repair voluntarily or do the mainten
3. IEEE 802 3u 100BASE T IEEE 802 3af Power over Ethernet LED indicator lights POE input power supply indicator light E O conrra Environment temperature Work temperature 5 45 C Work Humidity 90 No condensation Storage temperature 20 70 C Storage humidity 95 No condensation Note If any changes with product specification forgive without prior notice l F LKSAFE Professional UTP Balun Manufacturer Shenzhen Folksafe Technology Co Ltd www folksafe com PoE Switch FOLKSAFE AZ Troubleshooting Such as equipment malfunction according to the following way 1 Confirm whether equipment is installed as the manufacturer s installation requirements 2 Confirm whether RJ45 cable contacted well make sure no break whether line order production complies with the EIA TIA568A or 568B international standards 3 Confirm the working power of device is less than PD Splitter s max output power 12W 4 Confirm whether PoE device can work normally Use normal PD device to test if the PoE power supply works 5 Use a set of normal work FS PD1001 E10 device to replace the broken device by which to examine whether the equipment damage 6 If still cannot troubleshooting please contact with the manufacturer Making methods of RJ45 connector Required tools wire crimpers network cable tester 1 The wire sequence of RJ45 connector must complies with international standard of EIA TIA 568A or EIA TIA 568B
4. ance at other service points undesignated by Folksafe 3 Malfunction or damage by irresistible accidents and natural disasters such as fire lightning and earthquakes etc 4 Other troubles made by un proper use F oO LKSAFE Professional UTP Balun Manufacturer Shenzhen Folksafe Technology Co Ltd www folksafe com
5. load protection Panel schematic diagram l www folksafe com ea FOLKSAFE As Front view Back view 24 5mm cE DC output POE power input Data amp power input POE power output indicator LED can be connected to indicator LED POE switch or POE module only supports Data output lt Fast ethernet Bottom view a 4 SPLITTER Model PD1001 E10 Output Voltage DC 12V Output Current 1 08A Max IEEE 802 3af CE FE R HS Installation steps 1 Before installation please check the following equipments and accessories if there are any missing please contact with your supplier 1 1pc FS PD1001 E10device 2 1pc user manual 2 Please install as below steps 1 Before installation please turn off the power of all signal sources and the monitor in case of the damage to transmission device 2 Use network cables to connect PoE power supply device and RJ45 port of PD splitter 3 Connect DC connectors and RJ45 port with right powered device 4 Check weather installation is correct and the device undamaged Before power on PoE device make sure that all connections are reliable l F LKSAFE Professional UTP Balun Manufacturer Shenzhen Folksafe Technology Co Ltd www folksafe com FOLKSAFE As Technical Specification COo reas Electrical interface parameters One input RJ45 port One Output RJ45 Plug One Power supply output DC Plug Protocol Standards IEEE 802 3i 10BASE T