        HCA4 User Manual
         Contents
1.     Click the    Built in Input    Tab and select the    Use high speed counter    Check Box for  high speed counters 0 to 5  and then set the counting mode  reset method  and input  setting       Reading the High speed Counter present value PV  with    PRV Instruction    Execution condition              C1  Port specifier  example for high speed counter input 0   7777       Control data  for reading PV          amp  First destination word   15 0             High speed counter PV that was read         Reading the High speed Counter Frequency with a PRV Instruction    Execution condition                 C1  Port specifier  example for high speed counter input 0         C2  Control data for reading frequency  10 ms sampling          S  First destination word  5       datalowerbytes       High speed counter frequency    Present frequency   that was read  data upper bytes    Number of frequency measurement   1 input  high speed counter 0 only   inputs    Frequency measurement range High speed counter 0        D100  D101    Differential phase inputs  0 to 50 kHz  All other input modes  0 to 100 kHz    Note  If the frequency exceeds the maximum value  the    maximum value will be stored     Measurement method Execution of the PRV instruction    Output data range   Differential phase input  0000 0000 to 0003 0040 hex  All other input modes  0000 0000 to 0001 86A0 hex    Restrictions      The frequency measurement function can be used with high speed counter 0 only          4 2 Examp
2.   ICI       HCFA CORPORATION LIMITED    User s Manual    for HCA4 series Programmable controller    1  Product overview  1 1 Product naming rules    Contents    HC indicates the Chinese Characters Pinyin Initials    Hechuan          indicates series number of PLC       PLC Types  A1 A8    36X indicates 36 input points     Input points of A4 series  8X  14X  20X  24X  28X  36X   24Y indicates 24 output points    Output points of A4 series  8Y 12Y  14Y  16Y  20Y  24Y   Total number of input amp  output points    16 points  26 points  34 points  40 points  48 points  60 points  R T  indicates output type of PLC   R  relay output T  transistor output   A D  indicates power supply type of PLC   A  85V 264V AC input D  20 4V 26 4V DC input       1 2 Part names  Example  HCA4 36X24YR A    Hoa   15x24 TR                    DStatus indicator  POWER LED  Lit when power is ON   RUN LED  Lit when executing a program in either RUN or MONITOR mode  Not lit when Operation is stopped in PROGRAM mode or due to a fatal error  ERROR LED  Flash when a non fatal error has occurred  including battery alarm   HCA4    1    operation will continue   Lit when a fatal error or a hardware error has occurred        4 operation will  stop and all outputs will be turned OFF    2 Input indicator  HCA4 input is duodecimal  One channel        12 points   Output indicator  HCA4 output is octal  One channel for 8 output points   4 RS422 4485 Communication port  Operating according to arrow directions   65422 Co
3.  supply DC power supply                                Manual         HCFA HC HCA4 001  Date        15   2013     10    
4.  with transistor output     4 Guidelines for high speed counter input and pulse output  e4 1 Example of using high speed counter input  The overall procedure for using built in HCA4 functions is described below     1    Select functions    Making the settings in  the PLC setup       Create ladder program    Special instructions    Writing related auxiliary    area words    Reading related    auxiliary area words    Transfer PLC setup    and ladder program    Start operation       Select the function to use     Example  Interrupts  high speed counter input and pulse output     Set the function with applicable numbers using the CX programmer   Example  Input interrupt      and high speed counter 0  Parameters in the PLC Setup must    be set for the following function     e Input interrupt e Origin searches   Quick response input   Minimum cycle time    High speed counters  Serial communications    Write ladder diagrams using the CX programmer     Example  Permitting interrupts with the MSKS instruction and programming high speed    counters with the CTBL instruction     Example  Stopping high speed counters     Example  Reading the present value of a high speed counter     Transfer the PLC setup and ladder program from the CX programmer to the CPU unit     Set the power of HCA4 CPU unit OFF  then ON again      Start PLC operation      Precaution for correct use    The power supply must be restarted after the PLC Setup is modified and transferred in  order to enable the settings
5. age 24V DC   10   15     Operating voltage 20 4 to 26 4 V  range    Allowable 5ms  If less than 5 ms  the PLC will continue operation   momentary power If 5 ms or more  the PLC will be shut down    failure period    Inrush current 15 A for 0 1ms  Power 8 W 15 W  consumption W     3 Input  output wiring diagram  3 1 Input wiring diagram       Programmable controller  Sinking  Programmable controller  Sourcing        AGIOO 240V    j wire sensor             Wiring diagram of input terminal  Sinking  sourcing     Input  CIO 0 00  CIO 0 01  e            Input indicator                                                       5                 d KA      m      Internal  T            i circuits  COM              a  2 100 KHZ Internal circuit of high speed input        CIO 0 02 0 07           R434  3 3K   IK R905             PHC 110  ILFPISSCIE    GND    b    100 02 0 07 internal circuit      Precaution for correct use      X CIO 0 08 2 11          R437  4        560R       7        lt  5 5         _       102    TLP291    ul  Control        ClO0 08 2 11 internal circuit of normal input    Unidirectional coupling was used in photocoupler input for all HCA4 series  and all inputs    can only be sinking input     3 2 Output wiring diagram    3 2 1 Relay output specification and wiring     lt 30V DC  x 240V AC   250V AC or less  if not a CE  UL     External power supply    Maximum load Resistive load    cUL compliant item    2A   1 point The total load current should not  exceed following 
6. are ver  9 2 or higher     Built in RS422 amp  485 Provided Online function of the port can be used only by the programming  2    Connection port for USB port    Back up time of Max  10 days at 25  C  Normal starting for more than 15 minutes    built in capacitor   Battery free Battery free operation if no battery is attached    operation In this case  only data in the built in EEPROM will be retained if the power is    interrupted for longer than 8 or 10 days        xPrecaution for correct use   For HCA4 CPU units  the following      area will be unstable after a power interruption    DM area  D   Excluding the words backed up to the EEPROM using the DM function      Holding area  H      Counter present values and completion flags C    e Auxiliary area related to clock function  A    Mount the battery  sold separately  to a CPU unit if the data in above area need to be  retained after a power interruption     2 Power specification  2 1 AC Power module specification           34 points 40 points 48 points 60 points    Supply voltage 100   240V AC   10   15     Operating voltage 85 to 264 VAC  range    Rated frequency 50 60 Hz    Allowable 10ms  If less than 10 ms  the PLC will continue operation     momentary power If 10 ms or more  the PLC will be shut down    failure period    Inrush current 100 V AC  Max 15 A for 5ms            Power 21W 30W   24V DC External   22V DC 400mA   FE RENI       2 2 DC Power module specification    om 40 points 48 points 60 points    Supply volt
7. le of using pulse output Only for transistor output models   SPED Instruction pulse output is used to specify the frequency and perform pulse output  without acceleration or deceleration     H Speed output    SPED  885     Port specifier    Output mode    Pulse frequency       P  Port specifier    0000 hex Pulse output 0  0001 hex Pulse output 1    M  Output mode  15 12 11 87 4 3 0         gt     0 hex Continuous mode  1 h amp X Independent mode       0 hex CW  1 hex CCW      Pulse output mode  1         Pulse   direction       Total Q hex    F  First pulse frequency word  15 0        F   Destination frequency lower bytes      0   100000 Hz    0000 0000     0001 86A0 hex     F 1   Destination frequency upper bytes    The unit of pulse frequency value is Hz     5 Terminal arrangements for       4 series  HCA4 8X8Y 1 A    27  mespwez m p wer com   Ww                 worms wr           4 14  12         5l 7ssTam pus osx O3 Duwo v 0                               ms  wir we  ws  wr  come   vor  wos  oom   wos   wor  eme   wiz         HCA4 20X14YLI A                      ww  ow  ws ew   wr  sm   ue   ur  LET                                                         LT w                come           wes       wr     wir                cm   zw  cw wer         ew vos                   mu                      HCA4 24X16YLI A    1 01 1 03 1 05 1 07 1 11 2 01 2 03       m Eme   NP                                         Difference between DC power terminal and AC power terminal   AC power
8. mmunication port  Operating according to arrow directions   OUSB port  Used to connect to a personal computer for programming and monitoring by  the Programmer for HCA4   Installation procedure  Start Windows and insert the Programmer for HCA4 Master Disk  in the CD ROM drive   The installation program will be started by the computer s auto run function  Complete the  installation process following the instructions provided on screen    Terminal cover   8 The right extension cover   9  The front cover  built in battery interface  40 Two analog potentiometer opening    1 3 External dimension    Points   um   Wm    Mm      Hearse pons       Wmz      9 ta                                       wo      9      M                                  __          9 8           1 4 Performance specification             Pelomawe 0  Program capacity 8K steps  DM Area capacity 8K words  of these 7K words can be written to the built in EEPROM     Mounting expansion Available  Not yet introduced     units and expansion  I O units    Models with transistor   Available  outputs    High speed counter   Increment  100 kHz x2 counters  10 kHz x 4 counters     Up  down  100 kHz    1 counter  10 kHz x1 counter     Pulse plus direction  100 kHz x2 counters    Differential phases  4x   50 kHz x 1 counter  5kHz x1 counter    Pulse output Supported  Models with transistor outputs only     Built in RS422 Provided Online function of the port can be used only by the programming       communication port softw
9. values of  common collector   Output 1 point common collector   2A  Output 4 point common oollector   8A  Output 8point common collector   8A                WX        Open circuit leakage current PEE                   About 10 ms  Circuit isolation Mechanical isolation  Operation indication When relay coil is energized  LED is lit      Precaution for correct use    The load short circuit protection circuit  When the output terminal load short circuited   printed circuit board may be burned  Please insert the fuse in the output    Contact protection circuit of inductive load  An internal protection circuit for the relays is  not provided in the relay output circuit for this product  It is recommended to use inductive  loads with built in protection circuits  When using loads without built in protection circuits   insert      external contact protection circuit composed of surge absorber to reduce  electromagnetic interference and extend the product life        3 2 2 Transistor output specification and wiring    1  Sinking output wiring           GND  DICIA3ZUATI06    v  Control       External power supply 5 30 V DC    Maximum load Resistive load The total load current should not exceed the  following values of common collector resistance  load    Output 1 point common collector  0 5A  Output 4 point common collector  0 8A    Output 8point common collector  1 6A               m  6    x Precaution for correct use  All outputs are set as sinking output modes in all       4 series
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Installation and Operating Instructions  MANUEL D` INSTRUCTIONS & PIÈCES  KOBIL mIDentity  Pentair Hot Tub Skimmer User's Manual  INSTALLATION INSTRUCTIONS  Giant BOWERY 72 User's Manual  SIP Strobe Operations Guide  Continental Platinum CP43879 User's Manual  INTIMITÉS  User Manual - Synkronizer Excel Compare    Copyright © All rights reserved. 