WireXpert - User Manual - Copper Certification Testing

image

Contents

1. IA Cat 6 Channel IA Cat 6 Permanent Link IA Cat 64 Channel al IA Cat 8 Draft Channel I IA Cat 8 Draft Permanent ink IA TSB 155 Channel DN wireXpert User Manual Chapter 5 Performing an AUTOTEST Press the AUTOTEST button once settings and limits have been selected WireXpert will use the last configuration or factory settings to perform the AUTOTEST if new settings are not configured WireXpert will display summarized result with PASS or FAIL once AUTOTEST is completed Press the View details button to view the comprehensive result or the Save button to save the results 2 09 06 2015 GU 09 06 2015 c 09 06 2015 Z8 A 1 A 1 TIA Cat 64 Channel TIA Cat 6A Channel see AUTOTEST in progress AUTOTEST complete View results 1 2 3 B A 7 8 5 Coco Qna coro Click on the parameter to display a more comprehensive individual result In plot view press the Worst Margin button to view the worst margin Press again to view the Worst Value or press the Manage button for more options 2015 05 26 2 C 09 06 2015 2 es 09 06 2015 es None IL RL ISO Class D Channel 9 a QOO 1A Gra coro 1 2 3 B 5 A 7 S Am m amm m ee m m RR RR UR RR i i il IMEEM Pair 36 Good Pair 45 Good v Pair78 Sei 25d eee LE 1 00 MHz 100 00 Good of Shield Good Wir
2. 09 06 2015 a 09 06 2015 Z3 0 09 06 2015 O Custom Connector Recent Connector Custom Connector Construction Performance Grade c M a Add customized cable Manage customized cables o Wi DW wireXpert User Manual Advanced Test Options Advanced Test Options determines how the test will be conducted and results will be displayed General o Locator If enabled WireXpert will display NEXT and Return Loss RL fault information in an AUTOTEST result Disabled by default o Cable Pairing Type Choose T568A or T568B copper cable wiring standard B selected by default o Start AUTOTEST On Connection If enabled WireXpert will perform AUTOTEST as soon as a connection between Local and Remote is established Disabled by default o Direct Attach If enabled WireXpert will perform Direct Attach copper installation test Attach Permanent Link adapter to the Local and Patch Cord adapter to the Remote unit to perform this test Connect Local unit to patch panel and Remote to field terminated end Disabled by default o AC Wire map If enabled WireXpert is able to measure test runs with Power over Ethernet PoE midspan devices in between The WireXpert supports cable runs with IEEE 802 3 af and 802 3 at injectors Disabled by default Lab Labratory use only Please contact your local WireXpert Vendor for more information o WireMap Test If enabled WireXpert will ignore
3. A1 Wx4500 A3 TRAME Wx4500 None D olninlnln ln LL PS PU PU F Local Ser No pw20100003 Remote Ser No Cable Manufacturer Generic UTP Cable Name CAT 6A UTP Cable Type UTP Connector Manufacturer Un Shielded Connector Connector Name UTP Mod Jack 6A Connector Type UnShielded Limit TIA Cat6A Channel bIk flrO tel 1 rck 1 pnlI 0 por1 Total Records 14 Selected Record No 1 v Measurement Value Margin Length m Delay ns Cable NVP Resistance Ohms Insertion Loss dB Return Loss dB NEXT dB PSNEXT dB ACRF dB PSACRF dB Refer User Manual eXport for more information on how to use the software DN wireXpert User Manual Appendix A Icons Glossary Add Adds a site operator or customised cable connector to the database Cancel Discards option isl Manage Enables Rename and Select all option 1 Device info Displays device firmware build information Restart Restarts current procedure Retest Performs an AUTOTEST on selected result on List Based Testing Xu Delete Deletes a site operator or customised cable connector from the database Format Reset Performs non reversible setting data restoration to factory defaults rl Okay Confirms and saves current option Save Saves current test result Icon will disappear after a successful save
4. None NEXT RL TIA Cat 64 Channel N a ee Data 7 73 Location 0 40 Data 5 32 Location 0 40 10 0 20 m NEXT Locator 3 I ile RL Locator 0 00 m 0 60 m 0 00 m 0 60 m Cancel Pairs Local Remeeirs Local Remo Pairs Local Remeeirs Local Remo S 249 6 V S 4 5 3 6 V Wu vNu5 v S 4 5 1 2 F 3 6 7 8 V Vee Nos v Nera SF 0 2 0 8 AEST 7 A Locator To enable press the NEXT Locator Return Loss Locator SETUP button Test Settings Test Options Locator Managing test result s Test results can be manually saved by pressing the Save button after an AUTOTEST is completed When prompted enter label name and click OK to save 09 06 2015 09 06 2015 a 09 06 2015 Ye pos Enter Label pet TIA Cat 6A Channel TIA Cat 6A Channel CCo A NT Co ro COTE wr Qoo A GIG Go ho e MONAT eor The Save icon will disappear once saving is completed Pass test results will be automatically saved with reference to the selected Label Source SETUP Project Settings Label Source when AUTOTEST is completed DN wireXpert User Manual 09 06 2015 Project Settings Unspecified gt Unspecified gt Label Source Simple Label gt Next Label am Project To view saved results Press the DATA button Select Copper or Fiber and press the View button Select the test resu
5. Choose from a list of standards to determine the performance criteria in a given category or class Three of the most commonly used limits will be listed in the Recent Limit list Press the SETUP button gt Test Settings gt Test Limits to choose from a list of commonly used limits Three recently used limits will be on top of the list 09 06 2015 a fo 09 06 2015 2 es 09 06 2015 2 es Test Limit Recent Limit IA Cat 5e Permanent Link IA Cat 6 Channel Cable amp Connector Cable CAT 6A UTP gt Manufacturer Generic UTP NVP 68 gt IA Cat 6 Permanent Link Limit Standard Connector UTP Mod Jack 64 gt IA Cat 64 Channel IA Cat 8 Draft Channel Advanced oo in IA TSB 155 Channel Cable Choose from a list of cable manufacturer for more specific test parameters If unsure of manufacturer choose Generic UTP or Generic Shielded or Customized Cable to create custom cable Press the SETUP button Test Settings Cable Manufacturer to choose from a list of cable manufacturers If unsure of manufacturer choose Generic UTP or Generic Shielded or Customised Cable to create custom cable Customized Cable Click Add to add or Delete to remove customized cable s from the customised cable list DU wireXpert User Manual 09 06 2015 zy 09 06 2015 Z 09 06 2015 a Custom Cable Custom Cable Name Custom Generic Shielded Custom Customized Cable Pair Cou
6. WM DW wireXpert User Manual 09 06 2015 m 09 06 2015 m 09 06 2015 e O NEXT TIA Cat 6A Channel A 1 TIA Cat 64 Channel 000 2 OT wor 1 2 3 B 5 A 7 3 50 f Resistance 1 40 Ohms gt ei Laud Insertion Loss 45 20 dB gt 75 4 um hs ji nu of Return Loss 12 40 dB gt M f NEXT 11 90 dB gt lt f Return Loss 12 40 dB gt AUTOTEST results View detail results 125 of ACRF 14 70 dB gt The type of results will differ depending on the Test Limits and type of cable The SETUP button provides setting options necessary to conduct an AUTOTEST and configure the device These options include Quick Settings Quick Settings provides quick selection using predefined TIA CAT 5e 6 6A and ISO Class D E EA FA configurations for UTP FTP cables WireXpert will detect if Channel or Permanent Link adapter is used and changes its test limits automatically 09 06 2015 Zi 09 06 2015 zy gt 09 06 2015 Z mw Quick Setup CAT 6A Test Settings Limit TIA Cat 64 Channel Cable Generic UTP NVP 68 Connector Generic Unshielded Project Settings Site Unspecified Label Source UnShielded Shielded Simple Label System Settings gt DW wireXpert User Manual Test Settings Test Settings provides results oriented configurations necessary to perform an AUTOTEST Test Limit
7. completed You will receive any of the following 4 results after the AUTOTEST e Green PASS Good test result in accordance to pre defined settings e Green PASS PASS result with one or more test parameters that have margin in the range of uncertainty of the tester e Red FAIL Unacceptable results with severe disturbance on one or more test parameters e Red FAIL FAIL result with one or more test parameters that have negative margin in the range of uncertainty of the tester Note Marginal Pass Fail is enabled by default Press the SETUP button gt Test Settings gt Test Options Lab Marginal Pass Fail to change the presentation of the test result to clear PASS or FAIL results Uncertainty of the tester is then not taken into account Contact Psiber Data for more information You will be given the following option after performing an AUTOTEST e Retest can be conducted on a PASS or FAIL result if list based testing labeling scheme is selected e View details will display additional test parameters and plots e Save test results to device An AUTOTEST will fail in the event of missing connection between the Local and Remote units wrong settings configured or if setting reference is required WireXpert will perform an initial wire map test before testing other parameters Disable wire map test at Test Settings Test Options Lab Wire map to bypass this test o
8. failed wire maps during test Enabled by default o Marginal Pass Fail If enabled WireXpert will display marginal pass PASS and marginal fail FAIL results Enabled by default o Save Phase Data If enabled WireXpert will generate information for phase data plot generation Export saved results to CSV format using eXport software to obtain phase data Impedance plot will be displayed on eXport Disabled by default o 3 4 dB Rule If enabled WireXpert will ignore RL failures if Insertion Loss IL is lt 3dB and NEXT failures if IL is lt 4dB Disabled by default Project Settings Project Settings provides non results oriented configurations before performing an AUTOTEST EELLLLLLL EE DN wireXpert User Manual Site To add a site D Press the SETUP button gt Project Settings gt Site to begin adding a new site Click the Add button to add a new site Enter a Site Name Site Name is a required field Test results and label source will be saved under the created Site Site Address and Site Notes are optional fields but they provide additional information of the site Press OK to save site and proceed By default WireXpert creates an UNSPECIFIED site for default saving as long as new sites are not created 09 06 2015 Zw 09 06 2015 Z 09 06 2015 Project Settings Site New Site Name Site Address Next Label A 1 Site Notes ana cr aM Project d To delete a
9. fl E File Import Export Settings Tools Help Languages DPB Oh Qu ESSA Please mark the desired site s you would like to import Site pw20100717 UNSPECIFIED _ pw20100003 UNSPECIFIED pw20100003 UNSPECIFIED FX pw20100003 NEW SITE pw20100003 DA CH PL pw20100003 DA PC PL pw20100003 DA CH CH pw20100003 PHASE DATA _ pw20201471 REGRESSION TEST 14 OCT Q Connected Connected DN wireXpert User Manual X File Import Export Settings Tools Help Languages DOBUddqe c 3 Device Type Cable Label Wx4500 blk fir04el 1 rck 1 pni 0 por1 Wx4500 blk lr0 el1 ck1 pnl 2 por1 Wx4500 blk fir04el 1 rck2 pni 0 por1 Limit Type TIA Cat 6A Channel 8 TIA Cat 6A Channel TIA Cat 6A Channel TIA Cat 6A Channel Q I um E Mere sm Wx4500 blkir04el 1 ck2 pni 2 por1 Wx4500 PR BLHAAXZA TIA Cat 6A Channel Wx4500 PRELHAA Y ZA eo wo TIA Cat 6A Channel Wx4500 PRBLHAAZZA TIA Cat 6A Channel Wx4500 A2 TIA Cat 6A Channel oon DO amp WH Wx4500 M TIA Cat 6A Channel Wx4500 A3 c TIA Cat 6A Channel Wx4500 None N NININ N TIA Cat 6A Channel a ee ee v Total Records 14 Selected Record No 1 Local Ser No Remote Ser No Cable Manufacturer Generic UTP Cable Name CAT 6AUTP Cable Type
10. for Horizontal Link generally refers to 1 Floor A Tel Room A Panel 1 Port The default 1A 1B for Backbone Cable generally refers to 1 Tel Room 1 Floor A Tel Room 1 Name 1 Tel Room 1 Floor B Tel Room 2 Name followed by Backbone Cable Cable 09 06 2015 es 09 06 2015 es Template Label Template Label IA 606 A Class 1 IA 606 A Class 1 Single Room Horizontal Link Single Room Horizontal Link IA 606 A Class 2 Single Building Horizontal lA 6506 Class 2 Single Building Backbone IA 606 A Class 3 IA 606 A Class 3 ids ampus Backbone Cable ENA ampus Backbone Cable i TIA 606 A Class 3 Campus Backbone Cable TIA 606 A Class3 standard labelling scheme mainly used to support labelling for multiple buildings in a single site Ee DW wireXpert User Manual The default A 1A A 1A generally refers to A Building 1 Name 1 Tel Room 1 Floor A Tel Room 1 Name A Building 2 Name 1 Tel Room 2 Floor A Tel Room 2 Name followed by Backbone Cable Cable 2109 06 2015 dl es Template Label 1A 606 A Class 1 Single Room Horizontal Link IA 606 A Class 2 Single Building Horizontal IA 606 A Class 2 Single Building Backbone Start Label A 1AJA 1A End Label A 1AJA 1A Free Form Free Form provides simple numeric increments to 2 or more prefix The default start A 1 and end B 5 labels will generate labels A1 to A5 and B1 to B5 2
11. saved site 1 2 Press the Manage button Select site s and press the Delete to delete site s WireXpert introduces the Manage button on version 7 0 firmware Manage enables multiple saved items such as sites operators customized cables customised connectors and results to be selected and deleted simultaneously DN wireXpert User Manual Operator To add a site po I9 p Press the SETUP button Project Settings Operator to begin adding an operator Click the Add button to add a new operator Enter Operator Name Press OK to save site and proceed By default WireXpert creates an UNSPECIFIED operator for default saving if new operators are not created 09 06 2015 Z 09 06 2015 Z 09 06 2015 Z Project Settings Operator Unspecified gt Operator F gt Operator Site Unspecified gt Operator F nants re Project e l m adus fx f z To delete a saved operator 3 Press the Manage button 4 Select operator s and press the Delete to delete operator s Label Source Press the SETUP button Test Settings Label Source to choose from a list of scheme DN wireXpert User Manual 09 06 2015 Z mw 09 06 2015 Z 09 06 2015 zy Project Settings Cable Label Source Template Label lA 606 A Class 2 Single Building Horizontal IA 606 A Class 2 Single Building Backbone IA 606 A Class 3 am
12. 109 06 2015 2 es Template Label IA 606 A Class 2 Single Building Backbone IA 606 A Class 3 ampus Backbone Cable ERANT Start Label End Label List Based Testing List based testing allows creation of label list in the eXport software on PC and then bring the list to WireXpert It further allows easy selection of labels from the list to help technician select the cables to be tested quickly This testing method is carefully optimized for typical test work flow and it significantly improves productivity 1 Insert USB flash drive to USB port on WireXpert Ee DW wireXpert User Manual g 224 a odio Device will automatically detect USB flash drive Select Label List Select the custom label list s to be copied from the USB flash drive Press Copy label files from USB to proceed Click OK 10 06 2015 S 10 06 2015 Se 10 06 2015 m Firmware List Based Test Label Source F List Based Test Label Source F v Upgrade Firmware Build 2171 7 0 gt Franklin Building Ibt Export Test Results Franklin Ibt Import RE pem eer NEC us ET mae x In mt Press the SETUP button Project Settings Label Source List Based Testing Select label source file and click OK to continue 09 06 2015 D 09 06 2015 YB 09 06 2015 2 Cable Label Source Cable Label Source None Franklin Building gt Simple Cable Label Template Label 6 l
13. EC CISPR 24 1997 modified A1 2001 A2 2002 EN 55024 1998 A1 2001 A2 2003 DIN EN 55022 VDE 0878 22 2008 05 IEC CISPR 22 2005 modified A1 2005 EN 55022 2006 A1 2007 Aw Pal Signature Arvind C Patel Quality Management Psiber Data Pte Ltd www psiberdata com Date December 14 2010 oo EH DN wireXpert User Manual Contents Chapter 1 Getting SEaFEBOU das vu T EIN deKs Draw sus VivSleq ententes Dole cochonne 7 Unpacking the box WX4500 FA WX500 FA nn nnne nnn nennen seems 7 Key differences between WX4500 and WX500 ss 8 WireX pert OVER VICW e 10 D al Control System DCS RON 11 Wire XPE AIP E a A O EA E E EA E T A E R 12 Copper Cable Certification I CSUN 22 282 enr ERU Dx NE EE asc T 12 Mise a E a E E A E S EE EE E 13 BAC AIO AIO a ea ee de D 13 POWE SUD a P 15 DIMEN IO a ee de a a MM ME 15 Environmental COHCICIOFIS astetentundiste Er EE en et den ed Do 15 Chapter 2 Configuring WireXpert oae ados cd eee uns cie 16 WV OO Sr MN d Busse ae a de ee 16 TOUGH SCO LAVOUE Tm 16 The One Touch Access BUTIONS 22 eden estet tots eb rekerk e rates eR ertsdt upto cie eee dessus 17 bags DOR FINI TE Sm Em 35 Chapter 3 Setting RETRO d een di qeN RENT E NIA ROTEN T eee ne toc nee cie 38 Chapter 4 Configuring an AUTOTEST cscscsccscscsccccccscsccccccscsccccecscscescccscncescececscesescess 39 Testing Guide for Permane
14. Hz 500 MHz Accuracy Specification Level 2G Level Ille Fiber Testing option Yes Class FA CAT 8 options Yes Patch Cord Test adapters Yes DN wireXpert User Manual For Users of WireXpert Software 6 x and Earlier The software on WireXpert since version 7 x features notable changes on the interface These improvements have been made emphasizing on loading time responsiveness and stability The main functions from the previous version remains unchanged The new interface is clean and simple providing quick settings selection and distinct identification between the Local and Remote units Booting up is faster and hardware remains compatible Main changes from previous version Status bar 1 BSL Units can now be identified by the background colours on boot up ABC Device name function is removed 3 Connection between devices can now be identified by the Talk set icons Devices are not connected Devices are connected Press icon to activate Talk set Mode Devices are connected in Talk set Mode Use headset provided in kit 4 Available storage can now be found in System Settings Settings 2 Storage 5 Battery information can now be found System Settings gt Settings 2 gt Battery SETUP gt Test Settings 1 Quick Setup can now be found in the main SETUP page 2 Site and Label Source can now be found in Project Settings SETUP gt System Settings 1 Operator and Auto Save Results can now be found in Pr
15. TION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met Operating procedure practice if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met General Safety Information Do not use the device if it is damaged Before you use the device inspect the casing Look for cracks or missing plastic Do not operate the device around explosive gas vapor or dust Always use the device with the cables provided Observe all markings on the device before establishing any connection Turn off the device and application system power before connecting to the 1 0 terminals When servicing the device use only the specified replacement parts Do not operate the device with the cover removed or loosened Use only the power adapter provided by the manufacturer to avoid any unexpected hazards dE DN wireXpert User Manual CAUTION If the device is used in a manner not specified by the manufacturer the device protection may be impaired Always use dry cloth to clean the device Do not use ethyl alcohol or any other volatile liquid to clean the device Do no
16. UTP Connector Manufacturer Un Shielded Connector UTP Mod Jack 6A Connector Type UnShielded Limit TIA Cat6A Channel pw20100003 Connector Name bIk flrO tel 1 rck1 pni 0 por1 Direct connection via USB cable 1 Connect WireXpert to your PC using a mini USB cable pU UE databases Launch eXport software Go to Import Device Measurement Length m Delay ns Cable NVP Resistance Ohms Insertion Loss dB Return Loss dB NEXT dB PSNEXT dB ACRF dB PSACRF dB Value Margin Go to File Create New Project to create new project space Select database and click Import Selected to import or click Import AII for all WireXpert User Manual X File port Settings Tools Help Languages A USB Flash Drive mH From PC 3 OTDR Other Format Connected X File Import Export Settings Tools Help Languages DOBSUyds ee Do i Coach PHASE DATA CT liNSPCEIFIED TX AC COXIPLE POE C DEMO Connected Device Type Wx4500 Wx4500 RE rE Ji Cable Label Overall Result blk 4ir04el 1ack 1 pnl D por1 v blk ir04el 1 rck 1 pni 2 por v Limit Type TIA Cat 6A Channel Wx4500 blk4ir04el 1 ck2 pni 0 por1 X Wx4500 blk4ir04el 1 ck2 pni 2 por v go E rer Le Wx4500 PR BLAAAXZA 4 Wx4500 PRBLZA A Y ZA eo wo Wx4500 PRBLZAAZZA Wx4500 A2 Wx4500
17. Wire X pert User Manual Copper Certification Testing User Manual WireXpert v7 0 0 WireXpert4500 Copper IT EN U 201506 100 Copyrights 2015 Psiber Data Pte Ltd a Softing Company DW wireXpert User Manual WX Series WX4500 WX500 Wire pert Wire pert vm n te M LOCAL DN wireXpert User Manual Notices No part of this manual may be reproduced in any form or by any means including electronic storage and retrieval or translation into a foreign language without prior agreement and written consent from Psiber Data as governed by international copyright Laws Warranty The material contained in this document is provided as is and is subject to being changed without notice in future editions Further to the maximum extent permitted by applicable law disclaims all warranties either express or implied with regard to this manual and any information contained herein including but not limited to the implied warranties of merchantability and fitness for a particular purpose Psiber Data shall not be liable for errors or for incidental or consequential damages in connection with the furnishing use or performance of this document or of any information contained herein Should Psiber Data and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these Terms the warranty terms in the separate agreement shall control CAUTION A CAU
18. abels imported Refer User Manual eXport for more information on generating list based labels Press the AUTOTEST button to display the loaded cable list 10 Select label from list to begin AUTOTEST 11 WireXpert will automatically save a PASS result and return to the list or allows you o WH to save or conduct a re test for a FAIL result manually DW wireXpert User Manual 12 Select a tested label to view the results A green result indicates a PASS and a red result indicates a FAIL test A re test can be conducted by pressing Retest 13 Press the AUTOTEST button to return to the list AutoSave Enable option for WireXpert to auto save every PASS result System Settings Length Unit dE FT M Press the SETUP button gt System Settings gt Settings 1 gt Device Settings gt Length Unit to select the preferred length unit to be displayed Feet FT and Meters M are available Plot Y axis Direction Press the SETUP button gt System Settings gt Settings 1 gt Device Settings gt Plot Y axis Direction to select the how the plot s Y axis will be display Normal and Inverted Y axis are available Sleep and Auto Power off Interval For Sleep Interval Press the SETUP button gt System Settings gt Settings 1 gt Sleep Interval to select the idle duration before WireXpert enters the sleep power saving mode For Auto Power off Interval Press the SETUP button gt System Settings gt Setti
19. charging Reducing the screen brightness and enabling the sleep function allows WireXpert to run longer on a charge DN wireXpert User Manual WARNING Do not set reference or operate WireXpert while the battery is hot immediately after charging Make sure that the WireXpert is always operated within the allowed temperature reange from 0 409C If a significant increase or devrease of the temperature is discovered repeat the set reference procedure to remain the instrument s accuracy CAUTION Use only the supplied power supplies with the WireXpert kit Using other powers may damage the tester and void its warranty Battery Safety 1 To avoid the risk of fire burns or damage to your battery pack do not allow metal objects to touch the battery contacts 2 The battery pack is suitable for use only with compatible WireXpert devices Do not disassemble the battery pack There are no user serviceable parts inside Do not dispose the battery pack in fire or water 4 Handle a damaged or leaking battery with extreme care If you come into contact with the electrolyte wash the exposed area with soap and water If the electrolyte contacts the eye flush the eye with water for 15 minutes and seek medical attention 5 Do not expose the battery pack to high storage temperatures above 55 C 6 When discarding a battery pack contact your local waste disposal provider regarding local restrictions on the disposal or recycling of Li
20. ction between Local and Remote units DN wireXpert User Manual Chapter 4 Configuring an AUTOTEST After configuring the system settings follow these steps to set up an AUTOTEST 1 Press the SETUP button Project Settings a b C d Site Create or select a Site Operator Create or select an Operator Label Source Select cable labelling scheme Load labels from USB flash drive if using List Based Testing LBT AutoSave Enable option for WireXpert to auto save every PASS result 2 Press the SETUP button Quick Setup to select pre defined test limit settings using matching generic UTP FTP cable and FTP connector 3 Manual Setup Press the SETUP button Test Settings a b C Test Limit Select a test limit Cable Create a custom or select cable from list Select Generic if unsure Connector Create a custom or select connector from list Select Generic if unsure Test Options General i Locator Enable option to display the worst NEXT and Return Loss RL fault information in an AUTOTEST result Default has been set to OFF ii Cable Pairing Type Select if cable under test is paired using the T568 A or T568 B standard T 568A T 568B iii Auto Test on Connection Enable option to perform AUTOTEST on i e as soon as the connection between Local and Remote units is established Default option has been set to OFF G G O B B OBr Br O O G B B GBr Br iv Direc
21. d cost efficient method of replacing the link cords instead of the expensive link adapters Adapter Configuration Warnings WireXpert will display a warning a potential conflict is detected between the adapter and the test settings It is important to use the appropriate adapters as accuracy of measurements will be affected Cabling Certification and Testing Certification testing with WireXpert is highly intuitive and simple The AUTOTEST function performs a series of measurements between the Local and Remote devices and analyses the results to determine if the cabling run passes or fails the selected standards Copper Cable Certification Testing Test at both ends of structured twisted pair cables for the worst case performance are required in accordance to the ISO TIA standards All certification testing requires a two part test consisting of a main and remote unit both bearing similar test capabilities The test would be conducted with one end from the telecommunication closet and the other at the outlet DW wireXpert User Manual There are two primary considerations regarding the test method e Whether the user patch cords are included in the cabling run during the test f so channel test configuration is required f not link test configuration is required e Which standard TIA or ISO should be used Category or Class Permanent Link Configuration Tests The Permanent Link configuration is generally used in facili
22. e Room 208 Building 1 No 388 Tianlin Road 1103 09 The Franklin Xuhui District 200233 Singapore Science Park 1 Shanghai China Singapore 118223 Phone 65 6569 6019 ext 105 Phone 86 21 54133123 E mail asiasales psiber data com E mail chinasales psiberdata com Web apen psiberdata com Web china psiberdata com Europe Middle East Africa Psiber Data GmbH Psiber Data France a Softing Company 87 Rue du G n ral Leclerc Creteil 94000 Paris a Softing Company Lise Meitner Str 3 82152 Krailling Phone 49 0 89 89136060 Phone 33 66 097 0910 E mail info psiber data com E mail infofr psiber data com Web www psiberdata com Web www psiberdata com Softing Italia Srl Via M Kolbe 6 20090 Cesano Boscone MI Phone 39 02 4505171 E mail info softingitalia it Web www softingitalia it ER
23. e map Insertion Loss Return Loss Sn 6 a WireXpert User Manual 09 06 2015 D 09 06 2015 eS 09 06 2015 a 10 ul wis PI OLI Ii A A W i lh DTA TUE 80 Ni Nu J Hh whi Ww H y UN Th 90 m I GE D ee mA em 1 00 MHz Attentuation to Crosstalk Attentuation to Crosstalk Near end Crosstalk Ratio Far end Ratio Near end ISO only 09 06 2015 Zw 09 06 2015 a 09 06 2015 20 0 10 oe 1 00 MHz 100 00 1 00 MHz 100 00 Power sum ACRF Power sum ACRN ISO only Power sum NEXT DN wireXpert User Manual 09 06 2015 NC 09 06 2015 m es 09 06 2015 None J Local Y Remote eee ISO Class D Channel 1 1 3 3 b b 5 5 4 4 7 7 5 5 All Pairs Pairs Length m Delay Plot By Pair Pairs Resistance Pair 12 0 30 sone Pair 36 0 20 2 Worst Plot Margin Pair 36 Pair 45 0 20 2 Na E Pair 45 Pair 78 0 30 3 Pair 78 OverAll 0 20 eS NEAN mcm NEM mum Manage plots Resistance Length amp Delay NEXT and RL Fault Locating If the Locator option is enabled in the Test Settings Test Options WireXpert will display extremely critical troubleshooting information in the form of a Time Domain Reflection plot for NEXT and Return Loss Near End Crosstalk NEXT is an undesired effect of interference between two pairs in a cable measured at the same end of the cable as the inter
24. eXpert User Manual RJ 45 Ethernet port Enables communication between two sets of WireXpert for Alien Crosstalk testing Power Supply port Performs charging of device when connected to power adapter shipped with WireXpert One touch access buttons Main functional buttons AUTOTEST SETUP DATA and TOOLS for WireXpert Enables quick AUTOTEST and results viewing in a single click Brightness Control Adjusts the brightness level of the LCD display Navigation scroll buttons Performs navigation in long lists Context sensitive help Provides simple explanation relevant to the functionality on the current screen available in future version Probe interface connector When connected with different probe adapters e g CAT6A channel or Permanent Link WireXpert will enable specified certification test to be conducted Battery compartment Battery storage compartment Unscrew to replace battery WX AC BATT Dual Control System DCS WireXpert consists of two identical devices Local and Remote for dual end testing and certification Both devices utilise easy to use LCD touch screen technology and graphical user interface The DCS ensures the same graphical data on the Local units are received on the Remote unit real time improving efficiency and productivity significantly as test data and settings can be viewed from Remote and Local side In the event of a wire map failure the DCS will enable the operator on the far end to visual
25. estore the default settings that were loaded Touch Screen Calibra when this unit was shipped from the factory Restore Factory Sett Device Info H Settings 2 i CAUTION Restoring WireXpert to default settings is an irreversible action All user defined settings and stored will be erased and cannot be recovered Touch Screen Calibration Press the SETUP button gt System Settings gt Settings 2 gt Touch Screen Calibration to re adjust mechanical alignments of the touch screen Follow on screen instructions to begin calibration press and briefly hold stylus on the center of the Repeat as the target moves around the screen Device Info Press the SETUP button System Settings Settings 2 Device Information to check the device and probe serial numbers software and hardware version numbers device last calibrated date and probe test count EE DW wireXpert User Manual Click on the Info button for more information on the firmware 09 06 2015 4 m S Local Unit Unit SNo jw20301001 Hardware Rev 1 0 Software Ver 7 0 Calibration Date 31 Oct 2014 Probe Type Cat 64 Channel Probe SNo pa0110 1666 Probe Test Count 1759 Remote Unit Unit SNo pw201007 18 Hardware Rev 2 0 Software Ver 7 0 Calibration Date 20 Dec 2014 Probe Type Cat 64 Channel Probe SNo pa0210 0001 Probe Test Count 813 CAUTION To ensure accurate test results it is recommended t
26. fering transmitter In crosstalk the signals traveling through adjacent pairs of wire in twisted pair cabling interfere with each other Cross talk is undesirable The NEXT Locator displays the locations where crosstalk is excessive in the cable and indicate the exact location in meters or feet from the Local unit of where high crosstalk issue is seen View individual plot by selecting deselecting cable pairs Each two pairs of cables that have been tested for crosstalk are represented by different colour in the plot Return Loss RL is the measurement in dB of the amount of signal that is reflected back toward the transmitter Impedance mismatches and discontinuities caused by terminations to plugs or jacks and within the plug jack connection itself contributes to RL Excessive bends and damaged cable will also contribute to RL The greater the variation in impedance the greater the return loss reading The RL Locator displays the locations where return loss occurred during an AUTOTEST and indicates the exact location of where the highest return loss occurs View individual plot by selecting deselecting cable pair Each pair of cables that has been tested is represented by different colour in the plot Each peak result in NEXT and RL Locator could represent a new joint connection rarely a coupler and not necessary a bad cable that requires replacement Ee DN wireXpert User Manual 09 06 2015 eS 09 06 2015 A 09 06 2015 D
27. lid NVP value WireXpert Firmware Adapter Detection WireXpert firmware detects which adapters are connected to the Local and Remote units and configures the testing program to match these adapters Test limits are automatically changed to the type of adapter Channel or Permanent Link upon a Quick Setup selection For instance if a Channel adapter is attached and a CAT6 profile is selected the limit is automatically configured for CAT6 Channel Testing Digital Fault Finding WireXpert software automatically pinpoints cable fault locations and causes speeding problem resolution and increasing operator productivity Applications WX4500 provides complete certification solutions to major copper cabling and fiber optic installations Depending on requirements separate kits components or customised adapters can be purchased to provide more specialised tests and certifications Ee DW wireXpert User Manual WX500 provides the best cost efficient solution for installers who wish to certify only up to Cat6A WX500 runs on the same hardware and firmware as WX4500 but is calibrated to test only up to 500MHz For a list of available adapters please visit www psiberdata com Data Management WireXpert data management software eXport enables management of saved results such as finding renaming deleting printing and creating custom labels Please refer to User Manual eXport for more information Adapter Configuration WireX
28. lt Back Returns to previous screen Unsaved options will be discarded OQ Details View selected result gt Forward Proceed to the next screen ab Rename Renames saved test result in the DATA menu f USB Reads USB flash drive to perform upgrade firmware test result export or custom limit and label list import DU wireXpert User Manual Select all Selects all data on Next pair View next pair of screen plots of the current result E PO chart grid Toggles Scope live test Toggles between displaying of power between Live and Test loss in bar chart or grid format mode when inspecting a for fiber testing SM MM fiber with the inspection scope h Transmit ON OFF Toggles between enabling and disabling of light source on the Remote unit Fibermap Displays mapping of fiber being tested Q Set Reference Performs result referencing between the Local and Remote units DN wireXpert User Manual Technical Support Worldwide Offices Psiber Data s global presence ensures our customers receives sales and technical support anywhere around the world North America Softing Inc 7209 Chapman Highway Knoxville TN 37920 Phone 1 865 251 5252 E mail wirexpert softing com Web itnetworks softing com us Asia Pacific Psiber Data Pte Ltd Psiber Data China a Softing Company a Softing Company 3 Science Park Driv
29. lts click View to view results d m Select the next page for more results To delete a saved result Press the DATA button Select Copper or Fiber and press the View button Press the Manage button om Select result s and press the Delete to delete result s To rename a saved result Press the DATA button Select Copper or Fiber and press the View button Press the Manage button BD m OE Select result and press the Rename to rename result DN wireXpert User Manual 09 06 2015 m ow 09 06 2015 Se Franklin 5 gt 3 Pass 2 Fail Exporting test results into eXport PC Software 09 06 2015 e S eXport is a data management software designed to work seamlessly with WireXpert Saved results can be exported using the following methods USB Flash Drive 1 Insert USB flash drive to USB port on WireXpert 2 Device will automatically detect flash drive 3 Otherwise press the SETUP button gt System Settings 2 gt Storage gt USB 4 Select Test Results 5 Click OK to proceed 10 06 2015 M 09 06 2015 m Firmware Firmware Upgrade Firmware Build 2171 7 0 gt Upgrade Firmware Build 2171 7 0 gt Export Test Results gt V oo Test Results Custom Limits Copying Test Results to USB Drive Import Label List 6 Launch eXport software 09 06 2015 3 Firmware Export Test Results g
30. ly identify which pair of wires is causing the error instead of just a LED indication on traditional testers 2m 30m 2m 10m 2m m m M oo 00 x gt WW HmHm Fimm ml Traditional tester with single display screen usually WireXpert with LCD screens display on both Local on Local unit only and Remote units l B DN wireXpert User Manual WireXpert Adapters All test adapters are designed to fit onto every WireXpert units The device automatically detects adapters when connected and prompts to change in the matching interface depending on the type of adapter Via SETUP Quick Setup the matching limite can be selected automatically to the type of adapter Link and Channel Adapters Every standard WireXpert kit includes adapters for testing copper cablings in Permanent Link and Channel configurations Channel adapters connect to the patch cords at the wall plates and telecommunication panels WireXpert software compensates for the adapter s transmission characteristics to ensure test results accuracy Permanent Link adapters connect to the wall plates and telecommunication panel jacks WireXpert software compensates for the adapter s transmission characteristics to ensure test results will not be affected WireXpert s Permanent Link adapters high precision interface reduces the degrading issue between the RJ 45 jack and link cord providing highly accurate and repeatable measurements an
31. ngs 1 gt Auto Power Off Interval to select the idle duration before WireXpert performs an automatic shutdown DW wireXpert User Manual 09 06 2015 ay gt Device Settings Plot Y axis Direction Timing Settin Sleep Interval minut Auto Power Off Inter Sound Settings Dee Settings 1 Audio Settings 09 06 2015 SS Sleep Interval Never Sleep 10 Minutes 3 Minutes edd Auto Power off interval Never Auto Power Off 30 Minutes 10 Minutes did Press the SETUP button System Settings Settings 1 Audio Settings to configure various audio options for WireXpert 09 06 2015 ay Audio Settings Touch Click Speaker amp Tone Voice Prompt Volume Control Date and Time Touch Click Enable option to trigger clicking sound options on screen touch Speaker amp Tone Enable option to trigger system sound options e g boot up Voice Prompt Enable option to trigger system vocal notifications on action Volume Control Adjust for audio loudness Press the SETUP button System Settings Settings 2 Date amp Time to configure date time and display format Ee DN wireXpert User Manual 09 06 2015 Date amp Time Format ddimmiyyyy 24 00 mmiddiyyyy 12 00 yyyylmmidd Language 09 06 2015 a es 09 06 2015 Date amp Time Day EEE CE ES 04511 C 12 00 HUE OK wyyylmmidd Date setting
32. nt Pair 12 M Pair 45 M m AT amp T Cabling Systems Performance Grade NUN Belden erk Tek m wee c Go Learn NVP Add customised cable Manage customised cables When creating customised cable determining the cable name number of pairs construction type performance grade S FTP and cable s NVP is required WireXpert introduces the Manage button on version 7 0 firmware Manage enables multiple saved items such as sites operators customized cables customized connectors and results to be selected and deleted simultaneously NVP Determine the Nominal Velocity of Propagation NVP value of the cable The NVP factor is required to determine the accurate length of the cable run to be measured Based on this constant value the WireXpert performs it s TDR calculations Please see the cable s data sheet for the specific value of the cable type in use If the specfic NVP value is unknown go to TOOLS Learn NVP to determine the value using the predefined cable run of at least 30 meters or 100 feet DW wireXpert User Manual 09 06 2015 a Connector Press the SETUP button Test Settings Cable Manufacturer to choose from a list of connector manufacturers If unsure of manufacturer choose Generic UTP or Generic Shielded or Customised Connector to create custom cable Click Add to add or Delete to remove customised connector s from the customised connector list
33. nt Link Testing ss 41 Testing Guide Tor Channel T SCINR 2 2 sens INS Tau Y dUvESNVI 6 Un T Eu pNII Ae TE UT corses 42 Chapter 5 Performing an AUTOTEST ccsceccccscsccccccscsccccccscsceccccscscescecscscescececscesescess 43 NEXT and RE Fault LOCO TB uova iei qe aired aye Uie nasa cocta imde usto dao desse sU UI tutiPd ers EC I IUE 45 Managing test POSING ENERO 46 Exporting test results into eXport PC Software ss 48 CSS eh DIVE co castum acra EE ora UE RUN EUER II NIMM UM ERE MEUM M EIE 48 Direct connection via USB Cable abs bens daria Iu Sus S end arsi ido tan ES onacoo des Ev RU ur tix 52 Appendix A Icons GIDSSAFV she val Rs eXx C2R Ced CVM Aa a l o cq UU SEV Ka CAPERE SI Fed CMEa 55 Technical SUD DOM a de a ace NEEE Error Bookmark not defined nn MH DN wireXpert User Manual Chapter 1 Getting Started Unpacking the box WX4500 FA WX500 FA x E Soft case WireXpert WX4500 or WX AC SOFTCASE WireXpert WX500 Local and Remote Calibration Certificate amp USB Flash Drive Power Adapters Input 100 240VAC 0 8A Output 12VDC 3 0A WX AC CHARGER Talk set headphones LCD Protective Cover WX AC TALKSET1 WX LCD COVER CAT 6A Channel Permanent Link adapters adapters amp cords WX AD 6ACH2 Straps WX AD 6ALKIT2 o MH DU wireXpert User Manual Key differences between WX4500 and WX500 Feature WX4500 WX500 Frequency of measurement 2500 M
34. o have WireXpert units calibrated every year Contact vendor for more information The DATA button provides archive and data management ability to saved sites and test results Saved test results can be renamed or deleted in this option 09 06 2015 v 3 09 06 2015 v 3 09 06 2015 v Franklin 5 gt 3 Pass 2 Fail S Y View results Manage results Note Deleting a site will also delete its containing test results BEEN B DN wireXpert User Manual The TOOLS button provides advanced options for in depth troubleshooting and expert WireXpert users These options include Requires 7 Local and Remote N Requires ie Requires Local or Remote v Local and Remote Set Reference Performs loss Length amp Delay Performs a Wiremap Verifies the correct compensation through test to determine the length wiring and detects split pairs calculation from setting of and propagation delay of each referencing point pair using the NVP value programmed by the user Requires ff Local or Remote Requires Local and Remote Learn NVP Performs a test to Reset Probe Resets Perm About Displays worldwide determine the NVP of the Link adapter usage count once contact information for Psiber cable using the length value a new link cord is in place Data and Softing programmed by the user Note 30 meters 100 feet cable length is at least required to get a va
35. oject Settings SETUP gt Device Info 1 Device Info can now be found in System Settings gt Settings 2 gt Device Info DN wireXpert User Manual WireXpert Overview Power ON OFF button Touch sensitive color LCD screen USB device port Audio port USB host connector for flash drive RJ 45 Ethernet port for remote control Power supply port 12V One Touch access buttons Brightness control button Navigation scroll buttons Context sensitive Help button Probe interface connector Battery compartment Functionality Power ON OFF Button To turn on the device press the power button for 5 seconds To turn off the device press the power button and select OK on the power off dialog box Alternately press and hold the power button for 10 seconds not recommended The LED in the power button turns freen if the unit is turned on The LED on the power button turns red when the device is charging in standy by mode orange if it s turned on Touch Sensitive LCD screen Performs test executions and viewing of results USB device port Enables remote connection to the PC for remote control update and exporting saved results Audio port Enables vocal communication between Local and Remote units when connected to talk set headphones WX AC TALKSET USB Host port Enables results to be exported and firmware upgrade via USB flash drive Enables loading of custom limits and labels for list based testing DW wir
36. on to begin AUTOTEST PL adapter PL adapter gE3c a pgcoggcd B lt Patch Panel Horizontal Cabling Outlet Local Remote 09 06 2015 2 es IA Cat 5e Channel Cat 5e Permanent Link Cat 6 Channel Cat 6 Permanent Link Cat 6A Channel Cat 8 Draft Channel Cat 8 Draft Permanent DN wireXpert User Manual Testing Guide for Channel Testing Channel Ch test is comprised of the connection from an active device egg Router in a data rack a telecommunication outlet horizontal cabling and the connecting patch cords at both ends using Channel test adapters at each end of the link under test The recommended length for the patch cord from the patch panel and the outlet is 5m 1 Insert the Channel adapters into the Local and Remote units of the WireXpert 2 Power ON WireXpert Check that WireXpert is in Copper testing mode 3 Set reference is required if the units are being paired for the first time Refer to Chapter 2 on how to set reference 4 Choose the Channel limits and configure other settings if necessary 5 Connect the Local unit to the patch panel and Remote unit to the outlet using the patch cord connected to be used 6 Press the AUTOTEST button to begin AUTOTEST Channel under test Ch adapter Ch adapter G3 00000000 Or Patch Panel Horizontal Cabling Outlet e Local Remote 09 06 2015 2 a IA Cat 5e Channel IA Cat 5e Permanent Link
37. pert uses different adapters to test and certify different cabling runs The device automatically detects which adapters are attached and selects matching test parameters Adapter Insertion Counts Every WireXpert adapter can keep track of the number of tests performed This data ensures up to date information on the adapter s lifespan WireXpert will indicate a warning when the adapter insertion counts has expired the specified insertion counts lifespan This can be checked by pressing the SETUP button System Settings 2 Device Info Probe Test Count Upgrading the firmware Upgrade WireXpert firmware to ensure latest test standards and device features are up to date To upgrade WireXpert s firmware e Download and install the latest build of eXport software from psiberdata com e Export the firmware using an USB flash drive e Backup the test results in the device e Insert the flash drive to the USB port on WireXpert e Choose the upgrade firmware option and click Yes to begin upgrade If the upgrade prompt do not appear after inserting the USB flash drive press the SETUP button System Settings 2 Storage USB and select Upgrade Firmware Upgrading from an older version v7 0 0 Upgrading from older version is possible by following the same procedures WireXpert will detect the firmware from the USB flash drive and upgrade the firmware DN wireXpert User Manual 10 06 2015 m Export Import Cus
38. pus Backbone Cable ESRR Simple Cable Label Template Label List Based Testing ite ator Start Label End Label ee K i aaa Project Template Label None Manual input of label names is required for every saving of result Simple Label Provides simple numeric increments to a prefix To configure the simple label scheme 1 Enter desired Prefix e g Office Company X The prefix will remain unchanged by every result 2 Set a numeric start value e g 1 33 245 The counting value will raise one number with every test made 09 06 2015 Z mw Simple Cable Label DENN Start Value Template Label TIA 606 A Class 1 Single Room Horizontal Link TIA 606 A Class 1 standard labelling scheme mainly used to support labelling for a building or premises that is served in a single equipment room or a horizontal cross connect Ee DW wireXpert User Manual The default 1A A1 generally refers to Floor Tel Room Panel Port 09 06 2015 Z Template Label IA 606 A Class 2 Single Building Horizontal __ lA 606 A Class 2 Single Building Backbone IA 606 A Class 3 ampus Backbone Cable Ld Start Label End Label 2B B6 TIA 606 A Class 2 Single Building Horizontal Single Building Backbone Cable TIA 606 A Class 2 standard labelling scheme mainly used to support labelling of infrastructure with one or more telecommunication spaces in a single building The default 1A A1
39. s Time settings Press the SETUP button System Settings 2 Language to select preferred display language Storage 09 06 2015 a Language English Polski 4 e tina T rk e f Suomi Portugu s Fran ais Pyccku Deutsch Espa ol 4 Italiano Svenska Bas 0 C mibox C Sm Press the SETUP button gt System Settings gt Settings 2 gt Storage to view available storage space on WireXpert and USB flash drive if inserted Read USB flash drive by clicking the USB icon if prompt did not appear or closed after inserting USB flash drive o EH DN wireXpert User Manual 09 06 2015 M D 09 06 2015 2 Storage Local Storage USB Storage 418 44 MB of 3893 65MB Used Read USB flash drive Battery Press the SETUP button gt System Settings gt Settings 2 gt Battery to view battery level Battery levels of Local and Remote will be displayed if units are connected 09 06 2015 VS Battery Status Local Charging Remote Charging Restore Factory Settings Press the SETUP button gt System Settings 2 gt Settings 2 gt Restore Default Settings to restore WireXpert to factory settings Click OK to begin restoration DW wireXpert User Manual 09 06 2015 aZ 09 06 2015 ye Clock amp Languages Restore Factory Settings Date amp Time English gt Others Storage Battery Click on the Tick Icon at the bottom of this page to r
40. sponsive system and quick access menus WireXpert boots up to the SETUP screen It is categorised into 5 groups 09 06 2015 D 1 Status bar Quick Setup 2 Quick Setup group CAT 6 Test Settings 3 Test Settings group Limit TIA Cat 64 Channel Cable Generic UTP HVP 66 Connector Generic Unshielded Project Settings 4 Project Settings group Site Unspecified Label Source Simple Label 5 System Settings group System Settings 1 The Status bar displays the current date and time talk set and battery level The Quick Setup group provides quick selection with predefined configurations The Test Settings group provides results oriented configurations necessary to perform an AUTOTEST 4 The Project Settings group provides non results oriented configurations before performing an AUTOTEST 5 The System Settings group settings provides device time localization and device related configurations o MH DN wireXpert User Manual The One Touch Access Buttons Z 22 SETUP DATA AUTOTEST The fundamental philosophy behind the WireXpert User Interface is simplicity in its ease of use The main functions of the One Touch access buttons as follows AUTOTEST The AUTOTEST button will perform an immediate certification test on the last configured settings If no settings were configured default settings will be used Test results will be generated automatically after the test is
41. t Copying Completed 7 GotoFile Create New Project to create new project space o WH DU wireXpert User Manual 8 Goto Import USB Flash Drive and select the flash drive Click Import 9 Select database and click Import Selected to import or click Import All for all databases Open Project Save Project Close Project bit WireXpert User Manual X File Import Export Settings Tools Help Languages D P H 0 Q Cable Label vo T k d Kemere Heber PRE Tie Creer r basa Feder Phats Marire De ikal de Ererchihonie J Pul Dal zinc k FEsterence Je Flute de ils js Materia ds Hors de Prey de Lai Based 1 des FRA dee de nmp Tas x Puer rar iae pre 12 12 15 ERE A er eri eet idm A Dor Em 14441 FM Tek Fri File x kemeri Heire pra IL 11 14 ASE FFA er reet le A Mipu 2 14 Heer AM TH Fred Fhe X Iizarrx Jr a hi ask re aet X Frardkdin qi HI I 8 Tm 4s Tes En ext M nat City Fal pe l RES Tz marre A Praject Hien ial pra 1 1 In ns Pest rno ent X eh AIT pix 5 E3 1 Ph Tz Frol Fle Wes Fot nane ave ae hipe am Panpa le pro Hele Frankie Q Connected Tools Help Languages USB Flash Drive From PC OTDR Other Format U Connected WireXpert User Manual File Import Export Settings Tools Help Languages D B 4 Soc vd Please choose the deed USE Ash dise you woud ike te moni
42. t Attach Enable option only if performing Direct Attach installation test Default option has been set to OFF v AC Wire map Enable option to bypass testing DC parameters Default option has been set to OFF DU wireXpert User Manual Please ensure you have the following components before conducting the test e WireXpert Local amp Remote units WX4500 Permanent Link Testing e 2xPermanent Link Adapter WX AD 6APL2 e 2xPatch Cord WX AC 6ALCORD2 Channel Testing e 2xChannel Adapter WX AD 6ACH2 CAUTION Do not connect WireXpert to a voltage source such as an active telephone jack Excessive voltage will damage the units and the adapter and void the warranty DN wireXpert User Manual Testing Guide for Permanent Link Testing Permanent Link PL test is comprised of the connection from a patch panel to a telecommunication outlet horizontal cabling using Permanent Link test adapters at each end of the link under test 1 Insert the Permanent Link adapters into the Local and Remote units of the WireXpert 2 Power ON WireXpert Check that WireXpert is in Copper testing mode 3 Set reference is required if the units are being paired for the first time Refer to Chapter 2 on how to set reference 4 Choose the Permanent Link limits and configure other settings if necessary 5 Connect the Local unit to the patch panel and Remote unit to the outlet using the patch cord provided 6 Press the AUTOTEST butt
43. t permit any blockage of the ventilation holes of the device Environmental Conditions This instrument is designed for indoor use and in an area with low condensation The table below shows the general environmental requirements for this instrument Environmental conditions Requirements Operating Temperature 0 C to 40 C Operating humidity 20 to 85 RH non condensing Relative humidity 10 to 80 The WX4500 WX500 complies with the following Safety and Regulatory requirements DIN EN 55024 Edition 2003 10 IEC CISPR 24 1997 modified A1 2001 A2 2002 EN 55024 1998 A1 2001 A2 2003 DIN EN 55022 VDE 0878 22 2008 05 IEC CISPR 22 2005 modified A1 2005 EN 55022 2006 A1 2007 Regulatory Markings The CE mark is a registered trademark of the European Community This CE mark shows that the product complies with all the relevant European Legal Directives DU wireXpert User Manual Declaration of Conformity Manufacturer s Name Psiber Data Pte Ltd Manufacturer s Address 3 Science Park Drive 803 08 The Franklin Singapore Science Park 1 Singapore 118223 Declares under sole responsibility that the product as originally delivered Model Number WireXpert WX4500 FA WX500 Description Cable Certification Tester Kit Equipment Cable Certifier Complies with the essential requirements of the following applicable European Directives and carries the CE marking accordingly DIN EN 55024 Edition 2003 10 I
44. thium lon batteries 7 To obtain a replacement battery part number WX AC BATI1 contact your local dealer 8 Do not charge the battery pack if the ambient temperature is above 40 C Replacing Battery The batteries are located and secured at the bottom of the WireXpert units for safety reasons To replace the batteries Switch off WireXpert and disconnect external power supplies Unscrew the battery compartment and remove the cover Remove and replace a new battery into the compartment a E m Close fasten and secure the screw onto the compartment cover DW wireXpert User Manual CLLLLLR VAAN Power Supply e Removable rechargeable Li lon batteries provide more than 8 hours of continuous operation e AC power 100 240V AC plugs directly into the battery Alternatively the batteries can be recharged using an external charging kit that can be ordered separately WX AC CHARGER Dimension e Size 220mmH x 110mmW x 53mmD LOE e Weight approx 1 0 kg approx 2 2 Ibs B dl Environmental Conditions e Operating temperature 0 C to 40 C e Storage Temperature 20 C to 60 C H e Relative humidity 10 to 80 eee f AW nM e S amp P Sea y DN wireXpert User Manual Chapter 2 Configuring WireXpert WireXpert User Interface Touch Screen Layout The Graphical User Interface GUI in version 7 0 s firmware has been updated with a more re
45. ties still under construction and does not include user patch cords As the link configuration does not include the two additional connections of the patch cords performance standards are more stringent Special link adapters are used on both local and remote units for links that are under test Channel Configuration Tests User patch cords are included for the Channel configuration The pass fail limits for this configuration allows performance degradation inherent in the two additional patch cords included in the measurements thus are less stringent Special channel adapters are used on both local and remote units for channels that are under test Memory 1 Gigabyte internal flash memory External USB Flash Drive included allows for flexible data management and storage Memory Requirements The amount of memory that each test result takes up depends on the options that is configured before starting the test If plots are saved with each test file size of test results will be generally larger than one that has plots option omitted WireXpert allocates approximately 1 GB of internal flash memory for test result storage Battery Information WireXpert units are powered by Lithium lon rechargeable batteries These batteries contain circuitry that reports their state of charge to WireXpert The units can be powered by external AC DC power adapters A fully charged battery can operate WireXpert for five to eight hours before requiring re
46. tom Limits 09 06 2015 m Storage Local Storage NE Ni MB of 707 16MB Used ge AS AT MB of 3893 65 ME Used Upgrade prompt CAUTION If the Upgrade prompt did not appear press SETUP button System Settings 2 Storage and click the USB button to launch the prompt manually Test results and custom data in the device will be permanently removed during firmware upgrade Please export all results and data to USB flash drive before proceeding DW wireXpert User Manual Chapter 3 Setting Reference It is recommended to perform a set reference measurement if the Local and Remote units are being paired for the first time If there is a mismatch in firmware versions or expired calibrations AUTOTEST will be denied To set reference li 2 3 4 Connect a Permanent Link adapter to the Local unit Connect a Channel adapter to the Remote unit Connect the 2 units together using the patch cord provided in the kit Press the TOOLS button Set Reference 09 06 2015 Se 09 06 2015 2109 06 2015 c es Set Reference Length amp Wiremap Delay Learn NVP Reset Probe About Us aJ Factory Calibration Set Reference Success Lc M SEC DEN EC A A AN Set Reference will fail in the event of For Developer e Adapter probe mismatch i e two channel or permanent link adapters e Firmware version mismatch between Local and Remote units e No conne