Home
        Magnetek Material Handling IMPULSE •LINK 4.1 Basic
         Contents
1.       Magnetek Material Handling  IMPULSE   gt LINK 4 1 Basic    Instruction Manual       Electromotive    February 2006  Part Number  140 10350    Copyright 2006 Magnetek Material Handling      2005 MAGNETEK MATERIAL HANDLING   All rights reserved  This notice applies to all copyrighted materials included with this product  including  but not limited  to  this manual and software embodied within the product  This manual is intended for the sole use of the persons to  whom it is provided  and any unauthorized distribution of the manual or dispersal of its contents is strictly forbidden  This  manual may not be reproduced in whole or in part by any means  whatsoever  without the expressed written permission of  MAGNETEK     IMPULSEsLINK 4 1 Basic Software is Copyrighted by Magnetek  All rights reserved     Table of Contents    Warning  Caution and Notice    Chapter 1     Introduction  Overview  System Requirements    Chapter 2   Installation  Software Installation  Connecting to your PC  Creating Communication Profiles Using the Wizard  Getting Started    Chapter 3     Navigation    Chapter 4   Parameter Maintenance  Read From VFD  Write To VFD  Modifying Parameters  Parameter File Comparison  Security   Password Protection    Chapter 5   Monitoring  Monitor  Fault Reset    Chapter 6     Additional Menu Features  Print Preview  amp  Print  Parameter File Conversion  Viewing Parameters Keypad Simulator  Copy  amp  Paste    Chapter 7     Troubleshooting  Drive Fault References  
2.      Emulates the keypad and allows for  navigating the keypad menu remotely    Show Error Log     shows the status of IMPULSE LINK 4 1  Basic     IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006    9    Window   Allows for easy parameter window organization when in    Window L multiple window mode  The functions in the Window menu such as   Cascade  Tile Horizontally and Vertically  Minimize All  and Close  applications     Tile Horizontal    Tile Vertical    i Cascade All  function just as they do in other Microsoft Windows based  Minimize All       Close All     v  1 ParFile1      Help       Users Manual     Displays the User Manual   Acrobat Reader must      12  User Manual be installed     IMPULSE LINK Help     Provides information on communication  2  Impulse Link Help profile settings and troubleshooting  complete Index of VFD fault    codes  and a Search function       Electromotive on the Web     provides a link to the Magnetek  ad Electro motive On the Web Material Handling website       Check for Updates     provides a link to the download software  Check for Updates page of the website that offers updates   About   Displays the version number of this Electromotive  About Systems product  copyright and legal notices     IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  10    Chapter 4   Parameter Maintenance    IMPULSEeLINK 4 1 Basic software provides flexibility in programming  uploading  downloading  and saving  parameters  With full parameter descr
3.     1  CD containing IMPULSEeLink 4 1 Basic Software   2  Cable for IMPULSE G  VG  Series 2   3  Cable for IMPULSE  P3 Series 2 or IMPULSE G  VG  Series 3 drives    4  USB to serial converter    SYSTEM REQUIREMENTS    Supported Drives  IMPULSEeLINK 4 1 Basic supports the IMPULSEsP3 Series 2  IMPULSE G  VG  Series 2 and Series 3 drives     Supported Communication    IMPULSEeLink 4 1 Basic supports the following types of communication   Serial    RS232    RS485 7  Availability Availability    IMPULSE VG  Series 2  140 10261   IMPULSE VG  Series 3    IMPULSE  P3 Series 2 Modbus RTU Modbus RTU     1   USB to Serial converters are available if an RS232 serial port is not found on your PC    2   A USB to RS485 converter  an RS232 to RS485 converter or an RS485 card is required for your PC        PC Requirements  1  Pentium class or equivalent 500M Hz processor or better  2  256 MB RAM or better  3  Minimum of 100 MB free hard disk space available  4  Windows 98 SE operating system or better    IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  3    Chapter 2   Installation    SOFTWARE INSTALLATION    The IMPULSE LINK 4 1 Basic comes with a CD containing the IMPULSE LINK 4 1 Basic Software and  Adobe  Acrobat Reader for this technical manual     e Torun the IMPULSE LINK 4 1 Basic Setup  put the IMPULSE LINK 4 1 Basic CD into your CD drive  Run  setup exe from the CD if it does not start automatically        Loading Plugins          e Select the default choices during installat
4.    Communice Mp aee    various communication and application errors that may occur      8  IP Address   Commur i    Error Reference  IMPULSE Link 4 1 has adopted anew naming convention in dealing with    IE Part Camine Errors have been placed in the following categories     3    7  Max Resends   Comr        7  Parity  Communicatic CE   Communication Error        2  Part   Communication This includes problems opening ports  sending messages and temmeouts while    o  2  Protocol   Communic  waiting Jor messages       p slave Address   Cam DLE   Download Error    32  Timeout  Communice In addition to communication errors  there are additional errors that could cause  Troubleshooting     0 Drive Fault Reference f BIRCRTORE RO a       GHGs Series 2 IF   Initialization Fault   e Ge VG   Series 3 IMPULSE Link 4 1 runs through a sel check wren if begins  These faults  Af  Error Reference cause ihe application to fai to start        CE   Communication E OE   Operator Error      amp  DLE   Download Erro This includes errors due to the user attempting to do something the program   x Q amp  IF   Initialization Faulte does not support  such as attempting to load an unsupported file format       amp  amp  OE   Operator Errore OLE   Online Edit Error   SOL OLE  Delve EH EN This wicludes various errors that may occur while online with a VED  usually  Hes during editing        IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  19    By clicking on the type of error  you will be provided
5.    Unlocked                                                 A108   Enter Password 2         Model  2003 G  Series 3  Flash ID  8001 3    Copy  amp  Paste    The copy  amp  paste function works just like a  Microsoft Windows application  You can  highlight multiple rows and or columns using  either the    shift    key or your mouse and then  right click to either copy or print that  highlighted area  If you selected  copy   when the area is highlighted  you can then  open another Windows application and paste              Locked       IMPULSE Link 4 1 Basic    ParF ile1     File Settings VFO Tools Window Help    ju LE  SA rfe   Default Profile bd    A 4129    Properties   Read Write Help    Sel       view  Group F   Options hull         Description Setting Unit Cho VF OLY    Parameter    AI 14 Input Sel    F201    Zu  O 3chindvidual     x   A         r30  Diinpt   7 Binary    lao Ch    Select   2 Output Freq  J        AO Chi Gain      100 0      AO Ch  Select      3 Dutput Current        AO Ch2 Gain           Model  2003 G  Series 3  Flash ID  8001 3    IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  1     Chapter 7   Troubleshooting       Impulse Link 4 1 Hel  In the Troubleshooting section of i    the IMPULSE LINK 4 1 Basic Help  Menu  you can select either Drive  Fault References or Error   References  The Drive Fault  References provide the fault code   description and corrective action for  all of the IMPULSE G  VG  Series 2  and Series 3 faults and IMPULSE P3   
6.  Cm   H  Pts IT  Lr   aL os qei be   UP Fik oum  gm a Pn aru ie hiram  Ri Tar e  lw Pim 5 eel tml  al cum Um oam fn Lies   aia    L dul  Fi Lise Dedi  re mur lia oun fhe  oa  pel mm dom oae   rung pb  gom lki Vu oae 8 La       d  edu gel  ilm  olli  a L ug Fh Lies Ded  L  E i   ihe  mu   amp  mde cip gm n  m Pines Lun  Em    en FE BH Mii  atl zm hu oam Em liem  ba  it Visi T ee Iz WR Lee Dui  Bot wem Pee Z Sr Lie Dua  ay pd zum bom m   ama  mu  alim LEF Mui ien  RAS Luigi   EL  Like onem ri Mii Limi Coal   EIE imum bam bp bum  stu  a 18 ieee Pee I FR Lies i  ASI iim om  m Lime Lond   M i amm h 3 mer ram  mu  oe Libi eee 2  Fin  Lem Duis  Le lerr hae Eir Lim Loin  Ln iem Faces Er Lem Dung  i bhir ee   Sr lie i  La V mr og am doom  oui  ESO  amm bu gm i rmm  5       Print Name     Allows the user to select from any printer installed on  his her system  The user s default printer is initially selected   Print Mode   Allows the user to choose the printing style   o Compact mode  1 2 pages  provides parameter names and  setting values   o Detailed mode provides parameters  descriptions  setting values   units  as well    modified    information   o As shown prints all of the information as shown on the screen   OK Button     Prints the active parameter set to the selected printer in  the chosen format    Application    Cancel     Closes this dialog box without printing  Changes to  Customer Name  Application and Job Number are not saved     SI PAUL      lt     Text placed in the C
7.  Home    paman     inden    Search     IH Weinert 16 the IMPULSE   ink      i   Danimunicshan Freshna  3 ly Troubleshooting  i P d  rom Feul Eofenmmoe  i  G Eire Rolina    Pant Gpetons           Welcome to the IMPULSE Link 4 1 Help                         Series 2 faults  Therefore  you will not  need to consult your technical manual  when you have IMPULSE  LINK 4 1  Basic running  The Error References  Are communication errors that could  occur while running IMPULSE LINK  4   Basic           System    V a Tir   T p a TT  Leo 154r IT       Drive Faults References  IMPULSE LINK 4 1 Basic offers built in Help screens for the drive faults and or alarms   The Help screens provide advanced diagnostics allowing you to troubleshoot your drive from your PC  When you    click     on the fault  the help screen provides the fault code  fault name description  and the corrective action             Bridge 1    Drive Monitor    Bridge Drive   a  Series 3           230 3 20     Flash ID  BODL  3  Model  2003    Input Terminal  OG0000000  Output Terminal 10000000        15 00  0 00    Frequency Reference  Output Frequency    Output Current        Output Voltage i  Bus Voltage 316  Toraue Reference 96    Output Speed          Monkoring  Faulted    Control Method  DWF Control    zi                  EFT   Ext Fault  7    IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  18    Or you can simply go to the Help Icon and go to the Drive Fault References for a complete list of IMPULSEsP3 Seri
8.  Ted Eid HRD Fmibm Eni   a Li Fop am s hia Lae Mrd c   I aibe Pte AIEO bar P s Em hat Mayet Hele Dx  EA Low Pewee bim iia i Hi i feline piy peA Lim Fr Pm iir a Bird edie  Piper be     r F    E    are NOT       biski MEN Ea Casar ek Be i bisigh dui Da  Spm l  Pipi i Oca i     zl Preferences  louem Lek 4  T Acces Leys    ADVANCED    dreareri Leva Setup  Parna F r   Lisername   Bassvord      Erker Curent Password  Wew senama    CO ces a Neve Leana     Hew P amp tswond  choose a New Password        IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  13    Chapter 5   Monitor Function    MONITOR    There is a     Monitor    function  in the  Tools   drop down  which  displays a select  number of monitor  parameters  U   parameters  that  are continually  updated     Bridge Drive     ae Series 3  aft  Pleh ID     Control Method  2 05    bunk Tera    uinut Torte XE    Frequency Reference 15 00    Output Frequency 15 01    Output Current 0 0  Output Voltage 1185  Bus Voltage 7156  Torque Reference O 2    Output Speed    Miriga  Aree  Fera     Hz  Hz    Amps  VAL  WORE  2   Hz         ail       FAULT RESET  In the event of a  fault condition  you  will see the fault  icon on the Monitor  window  as shown  here     You can reset a fault in the Monitor window as long as the drive doesn   t have a  Run command and the fault condition no longer exists  Once you click on   the fault reset icon  a warning message will prompt you to accept that   you acknowledge the warning  When resett
9.  specific parameter  i e   Changing this parameter from the drive keypad would not be allowed with the current access level      Over Maximum   Under Minimum  A parameter with red text implies that its value is either greater than its maximum value or less than its minimum   An invalid value in the FIF file could result in this error     MODIFYING PARAMETERS    By double clicking on the row of the parameter you would like to edit  the setting column will appear as a drop down box   a text box  or a visual programming window   1  Drop down list box of parameter setting choices    List box  F Mat User    O  Mult Step  1 Multi 5tep Ret 3  z Multi Step Ret 4    3  Multi Step Het 5   d  Speed Hold 2   Be Accel Command   B Upper Lrt 1 AO  Upper Lmt 2 AO       This will appear for list parameters  Simply select the value from the list and     ENTER to accept the change    ESC to cancel the change    2  Text box for entering a parameter value    Text box       This will appear for numerical parameters   Simply type in the value of the parameter  in the base displayed  and     ENTER to accept the change    ESC to cancel the change    3  Visual Programming Window  click once on the visual programming icon       External Fault Response Selection    External Faut Selection    Detection tethod Extenal Faut Action Sething Result    HZ During Run Stop ton Past Stop                                  IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  12    This Visual Programming Window 
10.  the error code with description and correction action       Impulse Link 4 1 Help Seles    Hide Back Home Frit Options                MagnetekMH Home   Site Map    Contents   Index   Search        2  CE00    Part Already Ope    CEUDB   Port Could Not Og      CE100  Device Not Fauni s GT  CE102   Unknown Device Communication Error Reference  CE108   Timed Out  CE108  Timed Out  Resei  CE110  Connection Requ Device Not Found  E111   Baudrate Settings      Fault Code Fault or Indicator Mame  Description Corrective Action  A E115  con Pgs b T    CE114  Unknown Comm   CE100 Device Not Found  There was not a valid l  o A    to the loop back to ettings  CE203   Could Not Open F Device Not Seepepse t9 Hp dee message B OB bases Siete    requested  The target device is either not  CE204   Unknown Host rou connected  not connected properly  not powered up     2  CE205   Unable Ta Conne 3  Ensure the target device is    powered up or an unknown device   CE206   Host Could Not Bi connected properly    CES3DU   Protocol Driver Er   pci  ibis  CE3I3   Protocol Error  hac sini 2 S A  DLE   Download Errors Series  or P3 Series 2   IF   Initialization Faults Dive    OE   Operator Errors    OLE   Online Edit Errors    li         COMMUNICATION PROFILE TEST  The Communication Profile Test Utility provides a loop  back test to the drive to determine the status of  communication  This function is found in the Tools Profile    af Shop Crane     bridge  drop down menu    p W u  gt  El       Communic
11. A  HE HM Lai     333 Lim Farms 1l Um Lir 4a ie  e Be ee Dad AED  Lee Pa i l Vale lupa BS ee i Le La  AUI be Pom ie O Ha Live Lp EIU o H ED Phi Lee Dili ARLI Lue Fmum E Pia Lim onda   oe Bi Lee Cole  SERIES Lines Piim l Me Le Ei BSG A  le Les Ew 52411 Le Famam   Vin Lie se M    l Ta  zZEi4 Les Pera H Ha Lin Zaia BITE e HAET He Le Sol Ai Le Pam H Ha Lin Zia Ri44  04H Falha Cali  dN de Fena P Ha Lin noa Bis eH F   lbn Di eet Lem Faan T Faih Lis Bd    EHCET   Palin Los  AHi bn Pam H Ha ihn lua BL e hiin LEES AHi Lin aram PB Enim 4a BI  HE Bb R3     ai iem For I  Hai khe Shera Bid   CHEE   Ha ihn Bas a2 Lhrr Faai lI Tai hm oda H ee Fade Dia  ee Lem Pae M Fa lim npa iva eH Ha ihn Dow IH Ler Forum L5 Bales ma BW ee Bele La  EPIN lhe Barus He His i bma Tora B SOME  Hlb Ee APIS Lees Fee Ba Leos Lia BIdd ete leer Geile  ae lbr Pem Yi Hale Dore Bl fa ni HET  Halhin Doe ae iher Bore Si Haike Lra Alfa  H Pibe Ra   anni ibam Fem 21 Vin i bam pta EIU o EJ  Ha lbn Lrg ur  iher Freee    Hal bam ra Edd CHARTS Fed bam Dong  pem lbe Fami Ha Lier Shag Bld ee dH He Line LE  ADS lbe Free Faibn Srg Hi EHE Halbe Pers  a lh Parum  Fa Li ord Bia ste Halban oy a Lear Farum Di Vin lem rona W eee  Pike oy  p bee Panga J LIT  Jey Hy n ihe piy H eae Pyr Ha iket Bldg rH a  Hele ey  Ag bbam Pee 7  Vin tiam La Er og EI belie  ors ee Pee bin ibm ose Bd oo YB ee Eig  AG Lb Been Minbar icy DEDE oe  ie Lee Do A Uem Ree        He ir Md eh  Amie  c4  AI  lbe Peg lie data BA ath rr Hae hee Da Al  iber Pores 2 km teat
12. Communication Error References  Communication Profile Test  Show Error Log    p 14    p 15  p 15  p 16  p 17  p 17    p 18  p 18  p 19  p 20  p 20    IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  l    Warning and Caution    DISCLAIMER OF WARRANTY    Magnetek   s Electromotive Systems  hereafter referred to as Company  assumes no responsibility for improper  programming of a drive that resulted from use of this software  This software should only be used by a trained  technician who has read and understands the contents of this manual  Normal use of this software may result in  the drive parameters becoming modified  Improper programming of a drive can lead to unexpected  undesirable   or unsafe operation or performance of the drive  This may result in damage to equipment or personal injury   Company shall not be liable for economic loss  property damage  or other consequential damages or physical  injury sustained by the purchaser or by any third party as a result of the use of this software  Company neither  assumes nor authorizes any other person to assume for Company any other liability in connection with the sale  or use of this software        A WARNING    1  Read this user manual in its entirety before installing IMPULSE  LINK 4 1 Basic Software or operating the  IMPULSE  G  VG  Series 2  IMPULSE   G  VG  Series 3   and or IMPULSE  P3 Series 2 Variable  Frequency Drives  VFD     2  DO NOT connect or disconnect wiring  or perform signal checks while the electr
13. ParFle   par                          a ine ET     Fumar 2 CDU OA ud aue rS  DODGE ae m DE dn VeRO  nil LBEo dtr leri F ET  m ee ea Sarg ing DITE Lori ajj Ey  ascen iow T E gu OR m   Alio Sector Orga d xr Lees kid TOberbangepge Ging d  Cuber   Aer  Gee L Jo  cbane La    px deal Lan kii Arren paesi e ced Lew j  eet cadsarnrd Level  AB  Sorc menus If entes 1 3 Dpr Lie H kk lone rehi fae i l 2A Litas ier   Se  reum LS HF   oR ae EEL eue a LZ  PES i  Dai Ls  AHH  iadh   acie ene B EL Lr ke karia 121 n tb d  Ean t  ABE   PA rE   TH bht 2     yrn VH Ene EL  ee CUm branded Fe SH Crus bce  Ai Eu dE   D nop Use ded Ek Etr FHF Lomia T  yam Dol es    AHA De Lil J  v Loki k MESS scar Locked Seo far Loca   NI Uem Pa i i Vii Lice Ta E141 CHEST  MEDIE Dx E ri LE hiii 1 Mi Li Tei BLIA  H  Pi hee    Ee  A tem Pile Hi Lice JF EKAI  HA Pld Wie IE ee nhia H   La SE MISMA  HE PH EE DEI  A the Pi ie Ha Ls ES IHI  HE ies IE  I ADE Lus Vul PEL IE BA  H ee DE  AA   m Fh Hie Dra nA    He  i Deme Dd A Le Fake PE ere La  HRS Phe DEN  ADi LA ham Hi Lom EEI BA CHORI  D Qe Did MZ Like Fait Vh Lid EA    EMMRIO Phi Cee L     Ae Lhe Pikia Phi Lii Si SiS   OH H Lee Dah Atel Lice F  gus Halm Ei EH ee ed Le Ded  ARD L Flin be  H   Lc 0C Si Coe E Ei A Dh Fm um  Vis Lice dca PH SRI ld Lines L4  A hi Pan ee Ha Lum ria l  HE  Ba ee Ld A Lik Fi ae Ba Lie a Lo ee  Jaen Hem aun Hid Laer 44 Bit   HES  H Kies ER A Lie     uam  Halam Dna SU He Pie Who Len  AHE Lem named Ha Lar 4a BNA  eH H i ACIE Le Pi es E Ha Liem Lda BM
14. ation Profile Test U    BENI    Bequesting Port Connection    Granted  Opening Connection    Done    Testing Loophack   0EF    Testing Register OxlOo   0F    Checking for Gt VGt Series 3   0E   Checking Gt  VGt Series 3 RBRevizsion     UE     Detected DriveType  Gt VGtr Series 3  Flash ID   8001 3       Weise P feng Link Wires  Merson  4 102 Duki 57    Deginr  ng Wrke Parareters   Dre T wpe za ER Seres 34200 e Flash  D  8505 3  Pia ana  ema    par Wte Parameters Sutter Show Error Log   This function also found in the Tools drop down    menu  brings up an additional window showing the status of  IMPULSEeLINK 4 1 Basic        IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  20    
15. es 2   IMPULSE G  VG  Series 2 and 3 drive faults  as shown below         Impulse Link 4 1 Help    In x  e M e    Hide Back Home Frint Options                     Contents Index        h  E Index   Search               Brake Ans Lost    Communication Profiles    Du Troubleshaoting Fault Code Fault or Indicator Name Description Corrective Action  E u Drive Fault Reference   BEO Brake answer back signal is lost 1  Check brake answer    di Q G  VG  Series 2 during run  While running  the multi  back circuit     I ee flashing   eld  GG  Serias 3     Ea 2   Check terminal status  i Brake A function input brake answer back is lost      2  BB  Base Black i p  U1 10        Lost    z BEU  Brake Ans Lost     8  BE1   Rollback detec           BE2  No Current          BE3  Brake Release          BE4  Brake Answer 1  rm BE5  Brake Answer    BEG   Brake Stop Ala     8  BE    Brake Welded    2  BUS   Option Com Er       7  CALL  SFF G Com C       CALL   Cam Call        Can t Run   Drive nati       2  Can t Switch   Matar F  E CE   Memaobus Cam I          CF   Control Fault g    H Mmi Co m ee aa A aa T Y     4 m                                     COMMUNICATION ERROR REFERENCES  The Help function provides an overview of the possible errors that could occur while running IMPULSE LINK 4 1 Basic   as shown here        Impulse Link 4 1 Help _ m     m e zi    Hide Back Home Print Options                     Contents   Index   Search    IL  Settings           Baud Riate   Cammur            Channel
16. ical power is turned ON    3  Improper programming of a drive through the use of this software can lead to unexpected  undesirable  or unsafe  operation or performance of the drive     Failure to observe these and other precautions indicated in this manual will expose the user to high voltages  resulting  in serious injury or death  Damage to equipment may also occur     A CAUTION    NOTICE   No patent liability is assumed with respect to the use of the information contained herein  Moreover  Magnetek is  constantly improving its high quality product therefore  the information contained in this manual is subject to change  without notice  Every precaution has been taken in the preparation of this document  Nevertheless  Magnetek assumes no  responsibility for errors or omissions  Neither is any liability assumed for damages resulting from the use of the  information contained in this publication     IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  2    Chapter 1   Introduction    OVERVIEW  IMPULSEsLINK 4 1 Basic is a user friendly  Windows   based  interactive drive communication software  It is designed  specifically for communication between Magnetek s IMPULSE G  VG  Series 2  IMPULSE G  VG  Series 3   IMPULSE  P3 Series 2 drives and your PC with the supplied cable  The IMPULSEsLink 4 1 Basic Software allows you to  upload download parameters  program and monitor your IMPULSE drives   The IMPULSEeLINK 4 1 Basic Kit  Part  157 10028  contains the following components
17. ing a drive remotely  you need   to be sure that all personnel and or operators are notified  Once you have  checked the    I accept    box  the    Continue Fault Reset    button will be available        WARNING  Confirm Reset     EJ                   I Accept    This Function will rezet the current drive Fault   Proceeding with this Functian could cause an  unexpected  undesirable  condition     All operators and or pe  notified prior to resetting  accept and proceed wit  acknowledging that rese  Fault condition may lead  personal injury  or ewe     4 1 Accept             This Function will reset the current drive Fault   Proceeding with this Function could cause an  unexpected  undesirable  or unsafe operating  condition     All operators and or personnel should be  notified prior ka resetting the Fault  IF you  accept and proceed with this Function you are  acknowledging that resetting the current drive  Fault condition may lead to equipment damage   personal injury  or ewen death       Accepr Continue  Fault Reset                                    Fault Reset Icon       ls    Shop Crane   bridge      Driv    X        Demo Drive                GT Series 3   230 3 20 4   Flash     201 3  haces  zu   Control Methad  D v re control  hot Temna  ocd000000       Output Termina  100060000    Frequency Reference 15 00 He    Output Frequency ggd He  Output Current 0 0 Amps  Output Voltage DO  VAC  Bus Voltage 318  wDcC  Torque Reference Q0 6   Qutput Speed Q D He        e       Mo
18. ion   Impulse Link 4 1   InstallShield Wizard    ugbup ub    EL SLT              Free Updates  Patches  Additional features and bug fixes may be available from time to time  These may be downloaded from the Magnetek    Material Handling website at www magnetekmh com mg support  downloads software htm     Software Removal   To remove the IMPULSE LINK 4 1 Basic Drive Interface Software  open the Control Panel   s Add Remove Programs  dialog box  double click the IMPULSE LINK 4 1 Basic entry and choose Remove All from the IMPULSE  LINK 4 1  Basic Setup dialog box     IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  4    CONNECTING TO YOUR PC  Use the appropriate cable provided in your IMPULSE LINK 4 1 Basic kit to connect your PC to the drive     For IMPULSE G  VG  Series 2 drives    1  With power off  remove the keypad from the front corner of the drive   2  Connect the female connector into the drive   s keypad receptacle   3  Attach the DB 9 connector end of the cable to the serial communication port on the PC  For IMPULSEeP3 Series 2 and IMPULSE G  VG  Series 3 drives    1  With the power off  remove the keypad   2  Connect the RJ45 plug into the drive   s keypad receptacle   3  Attach the DB 9 connector end of the cable to the serial communication port on the PC     CREATING COMMUNICATION PROFILES USING THE WIZARD   The communication profile consists of the settings available to establish communication to the IMPULSE drives  There is  a wizard available to assist yo
19. iptions and visual programming  modifying parameters from your computer has  never been easier     Read from the VFD   allows you to load the parameter values from the drive   s memory  This can be accomplished  through the    VFD    drop down menu or the    Read    Icon  as shown below     i  IMPULSE Link 4 1 Basic    ParFile1       ge settings VFO   Tools Window Help  mock v    3  B  CE geadfom vro     Crh    E 8 sre ven Chien  Properties Plead x                   Miu EF yo z p A i i       i        AO   Acceus Level Advanced Level   l o    u lu    Ai42   Control Method Geen loos Ves      2   Kk         ALGI   MoGun   Standard Hoi     a   a   X     GISO Multi Sieg    Btn iritixkre    Reading Drive Parameters       16755    Cancel    Write to VFD   saves all parameter values from memory to the VFD  Again  this can be accomplished via the drop down  on the    VFD    menu or using the    Write    Icon as shown here  Writing to VFD may result in undesirable operation of your  crane  causing danger  personal injury or death  To proceed with the write to VFD function you will need to accept that  you acknowledge the warning message as shown here  Once you have checked the    I Accept    button  the    Continue write  to VFD    button will be available     i  IMPULSE Link 4 1 Basic    ParFile1    I Eie Getting  VFO Ik Widow Hep  uu a  do ce nena rifle  D ES B    E    irl          Properties Phe   Wri verts Parameter Fila To VFD    4s WARNING  Confirm Write        Theat Furalion   a
20. its current file name and  location    Save As     Saves the active file with a different file name or  location    Print Preview     Shows how a file will look when you print it   Print     Prints the active parameter set  Select Print options  in the  Print window dialog box    Properties     Displays the properties box to view the properties of  the active file    Exit     Closes this program after prompting you to save any  unsaved files     Communication     Allows communication profiles to be added   removed  edited  copied  imported and exported   Preferences   IMPULSE LINK 4 1 Basic settings for access level     IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  8    VED     i Read from VFD     Ctrl   B Write to VED Ctr D    Tools    ke    Lonvert         ampare       Communication Test     b  Monitor     keypad Simulator    Show Error Lag    Write Flash   Allows a binary file to be written to VFD flash    memory   FACTORY USE ONLY     Read from VFD   Loads all parameter values from the VFD to    memory     Write to VFD   Saves all parameter values from memory to the    VFD     Convert     Allows for parameter files to be converted from  one software Flash ID to another  must be within the same  series     Compare Parameters   Allows for comparison of sets of  parameter files    Communication Test     performs a communication test with  the VFD    Monitor     Displays a select number of monitor parameters   U parameters   updated continuously    Keypad Simulator
21. l   2 01 2006  6    GETTING STARTED    Run IMPULSEeLINK 4 1 Basic by clicking on the    L    icon found on your desktop  A splash screen will appear for a few    seconds while the subsystem loads        Loading Plugins          Select the profile that you created in the drop down profile box as shown here  and you are ready to access your    IMPULSE drive     IMPULSE Link 4 1 Basic    File Settings WFD Tools Window Help     E    a   Prot  Y Bridge 1       B    i   Au Default Profile  F     i    Properties   Read Write    Help    IMPLILSE Link 4 1 Basic       IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  7    Chapter 3   Navigation    The IMPULSE  LINK 4 1 Basic Software is a Windows based software with easy to use menus and drop down functions   The user is able to access utilities for uploading downloading parameters  comparing parameters  saving parameters to a  file  and more from the easy to navigate toolbar     IB IMPULSE Link 4 1 Basic Baa       File Settings vFD Tools Window Help          File     Mew    Ctr M  i  Open    Ctri o  Close  Save AS            Print Preview   amp p Print    Ctrl P      2 Properties  Exit    Settings  Communication    Preferences    New     Displays the controller properties dialog to create a new  factory default parameter set  based on the drive type  software  number  model  and kVA    Open     Opens or finds a file containing a parameter set for a  specific drive type and software number    Save     Saves the active file with 
22. ll cwerverila tha curren drive  p  r amelers  Proceeding with this function  Thould be done will caution  as changing  drive parameters ray lead to unexpected   undesirable  or unzafe operation of the drive                   All operators and or personal should ba  noted of any parameler change  that may  affect    pe get is pr    TAdvanced Level  Cars esd Open Leon Ve   Motor Landed Hait  Zone Bel PD Millie                thould be done with caution  as changing  drive parameters may lead bo uriaxpached        undatirable  of unca operation of the drive        All operators and or pertonmel should be  notified of any paramaeber charges that may  affect oper ation     inti gree ery Sete isime    inter Peaid 1 Lrizched       IF you accept and proceed with thr funcban   pou are acknowledging that owenwriing dria  paraenaters miiy lead to equipment damage   personal inpary  or even death     Enba Password 2   Lesen          x    cien     Mikal  TIT     horis  3  Fluch ID  8003 5       E Rie    IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  11    Modified Constant  A parameter with blue text implies that its value is different than its default setting     This list should match the modified constants list in the drive  with the exception of Al parameters     Read Only   A grayed out  highlighted parameter implies that it cannot be modified  This can happen for the following   reason      The Access Level of the current parameter set is lower than what is needed for this
23. ntong  Fauked    Fault Icon    1 Basic Instruction Manual   2 01 2006    14    Chapter 6   Additional Menu Features    PRINT PREVIEW    IMPULSEeLINK 4 1 Basic provides a compact printing mode that displays all drive parameters in only 1 2 pages  It also  prints a more detailed mode that lists descriptions as well as units for each parameter     Compact Parameter Print Preview    E Pring Presiesus       m eee lum    FErreeerreeerre    I           I  ei a  i ri   R    i Li Lua Es E  F  Sin  eet Cost E  m     Li ima lam lma li ii j krun b b anna  d Vias mm  uin bi d Erm  Tli bin i mar  on n A F i  alum E ee DU Tig E TEAM  ki  acum  bg  E Lana   EFI SS Le i  E hene     Ei lim i rj  BE  al Seer Bode P  i mu omm oma Fi il     ima  oo  mg m  Ae d LIT aT LI ik os  Lo  LI Cal mm  aol Vin Lote  Lun TE  E  AT Sa Lie Loin     i Hi ioe Dun Fu i mm om  i bp iam  om n F E  a maium Dau Fiii r   ry  ai micum  jur Ru  Ls en LS Pole TN  Lu  stes Lo mis  LA Vin oum Luin rn          Print    Printer    Name  MpcserpiMFCANZW    Ready   Canon iR3570 iR4570 PSs  138 207 8  137  PRINT  Canon IR45 0    Balbus     Type   Where   Comment     Page Range Print  hat      all    oO Current page    Print Mode     Seiechion   Application    Copies Job Number   Number of copies     Preview       Customer Name   icuste rises    Detailed Parameter Print Preview  mi                   Ti Cem  1 me 5   L  mI  E      oe Die am m   WEN S58 Rey   idm bE heim  mu PTT UE a     koun pnm Je arm ud i acm   ran Fan Numi dup
24. ted via the RS485 connection a CF00 Comm Error  will occur     Digital Operator Emulator NOTES     1  To Activate  Select the correct drive profile from the dropdown and  click the    button    2  The RUN command has been disabled for safety reasons      3  If the drive is put into  Program Mode  and not returned to    Run   b E Mode     the user will be unable to run the drive           JVOP 140 V0 20 ES  3  Sexes 2    RLIN    Y okese       IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  16    VIEWING PARAMETERS    The    View    drop down box allows you to select how the parameters are viewed  as shown below   all  modified  or another sub group      IMPULSE Link 4 1 Basic    ParF ile1      E File Settings VFO Tools Window Help      E  m  Profle   d Default Profile v    Efex      f X        4129    Properties   Read Write    Help    Modified Constants  Group 4   Initialize  Group B   Application  Group C   ESI Special Functions  Group D   Tuning  Group E   Motor  Group F   Options  Group H   Terminal       Init Parameters                         A1 05                                     CDO VF    Setting Limit      0 English a EM         2 Advanced Level      z D    2 Open Loop Ve                                                                                i 1 Standard Hoist    1 3 5PD Multi Step                                                               0 No Initialize                                                           A1 06   Enter Password 1         
25. u setting up the communication profile  In the Settings Menu  click    Communication     and  then    New     You will then see the following screen appear     RS237 Serial Communication Wizard   Introduction    The R5232 Wizard will help you set up an RSz32  connection profile For your IMPULSE Drive        IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006    5    Highlight the IMPULSE drive RS 232 for the communication through the keypad port  and then click    Select     The  wizard will then take you through the following three steps to set up a new communication profile     Step 1  Name  Description  Crane and Motion   Step 2  Common Port  Protocol  Slave Address   Baud Rate  Parity   Step 3  Finish    RS232 Serial Communication Wizard   Step 1          To keep your profiles organized  additional Fields have  been included  These are optional selections           Type  IMPULSE Drive  R5232 Communication           Modify the communication options for your R232  Connection  IMPULSE Drive communication constants  are also shown           Comm Port  Communications Port  COMI  w             Communications Port OMi  Protocol   Keyspan USE Serial Port  COM4    Slave Address  Ox1F           Baud Rate  9600        Parity  MOME    he iz FEiricr    RS232 Serial Communication Wizard   Finished     The R5232 Wizard is Finished collecting information          Ta build Ehe  New Profile 1  communication profile   press Finish               IMPULSE   LINK 4 1 Basic Instruction Manua
26. ustomer Name  Application and Job Number  fields appear on the printout     NOTE  Only parameters that are viewable in the    Parameters Window will be printed     IMPULSE   LINK 4 1 Basic Instruction Manual   2 01 2006  15    PARAMETER FILE CONVERSION     Convert    under the    Tools    menu allows for parameter files to be converted from one software Flash ID version to  another  within the same drive series         Parameter File Conversion Ed  Convert From   No File Selected  Source     Specifies the file to be converted     Select the Parameter File vau wish Eo convert by  5  urce    clicking on the  Source  button     Flash ID     Specifies the software type that the  file will be converted to     Destination Filename     Specifies the  Convert To   No File Selected  Destination filename   Flash ID   cepere Menem GU PME te eesti Convert   Converts the parameter file specified in  uno MEINE EGO USENET IOS UAE  Source  to the format specified in the software   Destination  button      2   version in the Flash ID  The converted file is  saved to the filename and path specified in   Destination Filename         JVOP 160 Eg  PAD REW     SEG REF ALARM     REMOTE Keypad Simulator   The keypad simulator emulates the  IMPULSE P3 Series 2 or IMPULSE Series 2 or 3 keypad  which  allows for remote keypad menu navigation  This function is  available when connected via the drive s keypad connector  not  with RS485 connection   If you attempt to run the keypad simulator  while connec
27. will pop up for hexadecimal and binary parameter values  The window  provides the actual parameter value description  so that you won   t need to use the technical manual to translate a  hexadecimal or binary value  Simply click the mouse on the table to modify  and then click on the    OK    box or hit  enter to accept the change  Click the    Cancel    box or ESC to cancel the change     NOTES     1  Ifachange is made  ENTER is not pressed to accept it  and the user clicks on another row or column  the  value will revert back to what it was before the change    2  Ifa parameter is changed to an invalid value  under the minimum value or over the maximum value  an  appropriate message will be displayed and the value being edited will revert back to what it was before the    change     PARAMETER FILE COMPARISON    The Parameter File Comparison function found in  the Tools drop down menu allows for compariso    of sets of parameter files     The    Show    drop down allows you to compare     all parameters of each file     only parameters with different values     or only parameters with equal values     SECURITY   PASSWORD PROTECTION  The    Preferences    drop down menu in IMPULSE  LINK 4 1  Basic software allows you to set the access level  username    and password     By logging out of the Advanced mode you will be in the User  mode  While in the User mode  the drives can only be  monitored  Write to VFD and Reset functions    available     PAR Fe Campore   ParFiel  par lo 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Samsung SMART CAMERA MV900F Užívateľská príručka  Wireless (Sem fios) - produktinfo.conrad.com  Baja de Mobiliario y Equipo en los organismos de la Administración  Version 4.0 Bedienungsanleitung  - A.J.Pinto  XC02 User Manual  Bewahren Sie diese Gebrauchsanweisung bei dem Coolfog  Bushnell 20-3031 Film Camera User Manual  ! WARNING - Napoleon® Products  Kenwood KRC-308S Car Stereo System User Manual    Copyright © All rights reserved. 