1.    aa Bullard    Eclipse    Thermal Imager  User Manual       Congratulations  Congratulations on the purchase of your new Bullard Eclipse Thermal Imager     The Eclipse represents a milestone in handheld firefighting thermal imaging   offering breakthroughs in portability  ease of use  and affordability to create   the market   s first truly personal issue thermal imager  Designed with high heat   impact resistant engineered polymers and infused with the latest thermal imaging  technology  the Eclipse is a powerful firefighting tool     The benefits of using thermal imaging technology as a firefighting tool encompass  nearly every aspect of a firefighter   s job  Thermal imaging is not  however  a  technology designed to replace current firefighting tactics  Rather  it is a tool that  allows the firefighter to be more effective and make better decisions  Some of the  many uses for your Bullard Eclipse Thermal Imager include     e Search and rescue   e Scene assessment   e Locating the seat of the fire   e Determining the spread of the fire  e Locating hot spots   e Identifying potential flashover situations  e Determining ventilation points   e Determining entry and exit points  e Overhaul   e Hazmat   e Wildland firefighting   e Incident investigation   e Training    AWARNING    Read all instructions and warnings before using this product     Your thermal imager is like any other tool  It must be used properly and safely  All  users should be trained on the proper and safe 
2.  have other rights which vary from state to state     Extended Warranty    The extended warranty has all the same terms and conditions as the one year  warranty  except it is for a period totaling two years  standard one year warranty  plus one additional year   This warranty can be purchased through any authorized  Bullard distributor        ISO 9001  certified      2012 Bullard  All rights reserved   Eclipse and Electronic Thermal Throttle are trademarks of Bullard    6050068839C  0512     
3.  registration  you will see a screen advising you  of the need to register your Eclipse  This screen will be displayed for 30 seconds   after which  the Eclipse will function normally  After registration  however  the  advisory screen will disappear and the Eclipse will power up to normal operation  in less than four seconds     Registration is accomplished by installing the Eclipse Control Panel software onto  your computer and then connecting your Eclipse Thermal Imager via the enclosed  data cable  when prompted during the installation process  Once this is done   simply follow the on screen instructions     Connecting Your Eclipse    After installing the Eclipse Control Panel software  you will need to connect your  Eclipse Thermal Imager to your computer  In order to connect your Eclipse to your  computer  please follow these steps  Figure 1      l  Press in firmly and pull back on battery release to release battery    2  Press in firmly and pull back on battery release and insert data cable assembly   3  Connect power adaptor to data cable assembly    4  Connect power adaptor to power outlet    5  Connect USB to PC     6  Turn on Eclipse by pressing power button     Figure 1       www bullard com       aa Sullard       Use and Operation  Power    To turn on your Bullard Eclipse  Thermal Imager  depress the black  power button located on top of   the unit  Figure 2   Upon pressing  the power button  you will hear   an audible click  and the thermal  imager will display t
4.  this printing  the Bullard Eclipse is not  certified as intrinsically safe  Failure to follow these instructions could result in  death  serious injury and or product damage     Thermal imaging is not a technology designed to replace current fire fighting  tactics  Rather  it is a tool that allows the firefighter to be more effective and to  make better decisions    Firefighters should not stop using basic fire safety tactics  All firefighters should  receive proper training on the following topics  how thermal imagers work  the  uses and limitations of thermal imagers  image interpretation  and the safety  considerations for thermal imaging use     Service    If your Bullard Thermal Imager is not performing properly  consult the Eclipse  Control Panel software and click on the Troubleshooting   FAQ tab  If the  information in your troubleshooting session does not help remedy your issue   contact Bullard Customer Service at 877 BULLARD  285 5273   Outside the   U S  and Canada  call 1 859 234 6611  Describe the problem to the Bullard  representative as completely as possible and provide the reference number  from your Eclipse Control Panel troubleshooting session  For your convenience   your representative will try to help you diagnose or correct the problem over the  phone  Before returning your Bullard Thermal Imager  you should verify with your  representative that the product should be returned to Bullard  Bullard Customer  Service will provide you with written permissio
5.  value  The accuracy of  the indicators is dependent on numerous factors including the distance from   the object being viewed and its emissivity  which is the object   s ability to radiate  heat  Units are calibrated with a preset emissivity corresponding with normal  construction materials  Objects with emissivities that vary greatly from this   such as metals and shiny objects  will reduce the accuracy of the temperature  indication  Additionally  temperature measurement accuracy decreases as the  distance from the object in the    crosshairs    increases     NOTE    The RHI and numeric temperature indicators provide a quick reference  to compare objects of similar emissivities to serve as a guide to pinpoint  intense heat sources  Due to the inherent issues with accuracy  use these  features with caution and verify indicated heat levels through traditional  means whenever possible     High Heat Colorization Feature    Your Eclipse may be equipped with High Heat Colorization  a feature which  colorizes heat levels in various color hues  Starting at 500 degrees  heated objects  are tinted yellow and gradually transition to orange and then to solid red as heat  levels rise  This feature identifies specific heat layers alerting firefighters to areas  of intense heat providing an enhanced visual awareness of the hottest objects in   a scene     Electronic Thermal Throttle      Your Eclipse may be equipped with Electronic  Thermal Throttle  ETT   a highly useful and unique  fea
6. actory within 48  business hours     Americas    E D  Bullard Company   1898 Safety Way   Cynthiana  KY 41031 9303   Toll free  877 BULLARD  285 5273   Tel  859 234 6616   Fax  859 234 8987  www bullard com    Europe    Bullard GmbH  Lilienthalstrasse 12   53424 Remagen    Germany  Tel   49 2642 999980   Fax   49 2642 9999829  www bullardextrem com       Asia Pacific    Bullard Asia Pacific Pte  Ltd   LHK Building   701  Sims Drive   04 03  Singapore 387383   Tel   65 6745 0556   Fax   65 6745 5176  www bullard com    Warranty    Bullard warrants to the original purchaser that the Bullard Eclipse and all  features accessories installed in the unit as well as battery charging units are  free of defects in materials and workmanship under intended use and service for  a period of one  1  year from date of activation  Bullard   s obligation under this  warranty is limited to repairing or replacing  at Bullard   s option  articles that are  returned within the warranty period and that  after examination  are shown to  Bullard   s satisfaction to be defective  subject to the following limitations     a  Article must be returned to Bullard with shipping charges prepaid   b  Article must not be altered from its original configuration   c  Article must not have been misused  abused  or damaged in transport     d  Maintenance and field replaceable items  if defective  are covered under  warranty for a ninety  90  day period from the date of purchase  These items  include     e Batterie
7. he Bullard logo   A thermal image will appear within  a few seconds  This image consists  of black  white and gray elements  indicating heat signatures of objects and scene dynamics  Warmer elements  appear as lighter shades  while cooler elements appear as darker shades        Figure 2    To turn off power  depress the power button     Battery Status Indicator    A battery status indicator  located at the bottom center of the display  indicates  the remaining battery charge for the Eclipse  A full charge Is indicated by a full  green bar in the battery indicator  During operation  the bar will deplete from left  to right  changing to yellow when it reaches 40  charge  and then to red when it  reaches 20   charge  At 10  remaining charge  the red bar will flash     NOTE    You will periodically observe a momentary freeze in the image  This is normal  and is a function of the self calibration shutter  The shutter will activate  every 30 seconds to three minutes  depending on the environment     Temperature Measurement Features    Your Eclipse may be equipped with optional temperature measurement features   If equipped with the Relative Heat Indicator  RHI   the display on the Eclipse will  Show a bar graph style temperature gauge  The RHI indicates the approximate  temperature of the object viewed within the    crosshairs    shown in the middle  of the display  The numeric temperature indicator  if equipped  functions in the  same way but indicates the temperature as a numeric
8. ing a proper program     Cleaning the Lens    The Bullard Eclipse lens is recessed in an impact resistant bezel  The lens can be  cleaned with a soft cloth and soapy water as required     Replacing the Video Display Cover Window    The display cover  Figure 6  has a scratch resistant hard coating to minimize  marring  However  if heavy scratching or gouging does occur  the cover window  can be replaced  To do this  remove the  four Phillips head screws along the sides  of the window  Remove the plastic display  cover window and replace with a new  one  part number ECLWINDOW   Do not  over tighten        Figure 6    CAUTION    Do not use solvents or paint thinners to clean your Bullard Eclipse Thermal  Imager  as they could permanently mar the surface or degrade the protective  properties of the casing     Do not intentionally submerge the unit underwater or subject the unit to high pressure  water  Follow care instructions described above     Failure to observe these instructions may result in product damage   Any damage caused by improper care is not covered under warranty        D A eE Fre tee    af a     T      a Gaal   J  Yn   Ge Ow i    Regs e  AVA  OLUILI   VW WVW WWe hs ta eae        aSullard       A WARNING    Do not attempt to disassemble the Bullard Eclipse Thermal Imager  Disassembling  the unit voids all warranties  For your convenience  TORX head screws have been  used to mark all areas that are non user serviceable    Like all thermal imagers sold at the time of
9. n and a return authorization  number     If the return is a non warranty repair  a Bullard Customer Service Representative  or your local distributor will provide you with a repair invoice estimate  To  authorize repair  you must provide a purchase order to your distributor for the  amount of the estimate  Once Bullard or a local distributor authorizes your repair   Bullard will issue you a return authorization number so that you can return the  unit to Bullard  Bullard will repair the unit and ship it from our factory within 48  business hours  If the cost of repairs exceeds the stated quote by more than 15   or by more than  100  a Bullard representative will re estimate your repair and  Bullard or your local distributor will contact you for authorization to complete  repairs  After repairs are completed and the goods have been returned to you   Bullard or your distributor will invoice you for the actual repair amount     NOTE    Prior to returning your Bullard Thermal Imager  decontaminate and clean  the thermal imager to remove any hazardous or contaminated materials  that may have settled on the product during use  Laws and or shipping  regulations prohibit the shipment of hazardous or contaminated materials   Products suspected of contamination will be professionally decontaminated  at the customer   s expense     Returned products will be inspected upon return to the Bullard facility  If the repair  is under warranty  Bullard will repair the unit and ship it from our f
10. one  second or turning off the Eclipse and turning it back on     Loading Unloading a Battery    To load a battery  Figure 4   depress and then slide the battery release switch in  the direction of the arrow indicated on the button  With the battery release switch  engaged  slide the battery into the groove in  the cavity located at the bottom of the unit  You  will hear an audible    click    when the battery is  properly seated  To unload a battery  depress  and then slide the battery release switch in the  direction of the arrow indicated on the switch   With the battery release switch engaged  grip  the battery by its exposed bottom section and  pull it away from the unit  Figure 4      NOTE    If the battery is inserted without first  retracting the battery release switch  the battery will not fully seat  If this  occurs  remove the battery and follow reload using the instructions above        Figure 4    The battery latch mechanism prevents accidental battery release upon impact     1     wa dg Ga aa ae  f f TA eS GH sm A    AI FA   Bal      TL  DI E F        TSS AC  P      ViVAVIVAVLY  VIVAVLY  LY   ww ww WW      Eclipse    Thermal Imager  User Manual       Charging and  Maintaining Batteries l    If you purchased an Eclipse Powerhouse  with your Eclipse Thermal Imager  see the  enclosed Powerhouse manual for charging  instructions  If you purchased an Eclipse  Thermal Imager only  you received a  charging base        To charge a battery in the charger  included with y
11. our Eclipse  place it in  the charging base  Figure 5   A steady  red light will indicate that the battery is charging  while a steady green light  will indicate a full charge  The system will detect the full charge and will not  overcharge the battery  A completely drained battery takes up to three hours to  fully recharge     Figure 5    As with all batteries  your Bullard rechargeable battery will experience a slow  drain of its charge during storage  The amount of drain varies widely based   on storage conditions  To ensure adequate battery life  charge each of your  batteries every two weeks or  for best performance  keep your Eclipse and spare  battery charged in your vehicle in the Eclipse Powerhouse    truck mount charger  accessory  part number  ECLPOWERHOUSE   If you are using a Powerhouse  charger  follow the instructions contained in the accompanying manual     NOTE    Ensure that the charging base is receiving power from a source via either  the AC or DC power adapters  If you do not see the red LED illuminate when  you place a battery into the charger  the battery is not charging     A WARNING    Do not allow the metal contacts on the battery to come in contact with a  conductive surface  such as a metal table or another battery  While the Eclipse    is equipped with protective circuitry to prevent product damage  contact with  conductive surfaces can complete the battery circuit and cause the battery to  overheat or melt  Failure to observe this warning may res
12. s   e Straps   e Display covers   e AC DC adapters    Bullard provides a limited lifetime warranty on the Eclipse outer shell  This  warrants that the outer shell is free of defects in materials and workmanship  under intended use and service for the original purchaser  Bullard   s obligation  under this warranty Is limited to repairing or replacing  at Bullard   s option  articles  that after examination are shown to Bullard   s satisfaction to be defective  subject  to the following limitations     l  Article must not be altered from its original configuration   2  Article must not have been misused  abused  or damaged in transport     3  When the outer shell is obsolete and Bullard no longer stocks the part  the  limited lifetime warranty will be terminated     In no event shall Bullard be responsible for damages  loss of use  or other  indirect  incidental  consequential or special costs  expenses or damages incurred  by the purchaser  notwithstanding that Bullard has been advised of the possibility  of such damages     Any implied warranties  including warranties of merchantability and fitness for  a particular purpose  are limited in duration to one  1  year from the date of  manufacture of this     Some states do not allow the exclusion or limitation of incidental or consequential  damages  or allow limitations on how long an implied warranty lasts  so the above  limitations or exclusions may not apply to you  This warranty gives you specific  legal rights  and you may
13. ture available on Bullard firefighting Thermal  Imagers  The ETT is ideal for pinpointing hot  spots during overhaul  searching for overheated  electrical equipment  or clarifying objects in  ambient temperature situations  To activate the  ETT option  locate the rubber cover on the top of  the Eclipse  Press the left side of the cover  which  is the left button on the throttle  to activate the ETT Figure 3   Figure 3   The ETT will automatically sense the hottest area in the scene and color  it blue  Continuing to press the left button  or holding it down  will further engage  ETT and will color more of the scene blue  eventually coloring even the coolest  objects blue     NOTE    As the throttle engages more of the scene  the blue will become lighter in  hue to help differentiate objects in the scene                  As you cycle through the scene  you ll see the symbol    TT    and a corresponding  number in the upper left hand corner of the display  The    TT    indicates    Thermal  Throttle    mode  The number  0 100  is a point of reference to indicate the level  of Thermal Throttle engagement  by itself it has no specific meaning  Most of the  benefits of the ETT are accomplished with the first few presses of the button  To  deactivate the ETT or lessen the amount of blue in the scene  press  or hold  the  right side of the cover  which is the right button on the throttle  Alternatively  you  can quickly deactivate the ETT  by pressing both buttons simultaneously for 
14. ult in permanent  battery damage  property damage and or serious injury     NOTE    New  fully charged NiMH batteries will provide a run time of more than three  hours  To extend the potential lifespan of your batteries  fully drain and  recharge each battery monthly  For best operational results  develop a clear  formalized plan for maintaining  charging  and replacing your batteries        A WARNING    The Eclipse Thermal Imager is extremely sensitive to intense  radiant heat    sources  Never point the Eclipse at the sun or any other source of extreme  radiant heat  as this could severely damage the thermal imager        Retractable Strap    The Eclipse Thermal Imager fits easily into a turnout gear pocket for convenient  storage while crawling or working  Additionally  Bullard offers a retractable strap  that can be used with the Eclipse  so that it is always at the ready  The strap  part  number  ECLRETRACT   purchased separately  can be mounted to a D ring on your  turnout gear coat and connected to the D ring on the Eclipse     Care Instructions    The Bullard Eclipse Thermal Imager requires little maintenance  For best results   after each use     e Clean the outside of the unit with mild soap or detergent   e Wipe the lens with a soft cloth    e Clean the display with a soft cloth    e Check screw tightness on cover display     e Store your thermal imager in the optional truck mount or in the delivery case  provided         All thermal imagers should be maintained us
15. use of thermal imaging prior to    using the Eclipse Thermal Imager  This is especially important for users who may  use the Eclipse Thermal Imager in hazardous or IDLH  immediately dangerous to  life and health  environments     Failure to follow this information could result in death or serious injury     Getting Started  Registering Your Eclipse    Before using your Eclipse Thermal Imager for the first time  it is necessary for you  to register the product with Bullard  Registration accomplishes several important  tasks  First  registration assures that you will always stay informed of the latest  product updates  service and training issues related to the Eclipse Thermal  Imager  Second  registration will reduce the startup time of your imager from 30  seconds to less than four seconds  Third  registration activates a security feature  on the Eclipse that saves your user information to the imager itself  With this  feature activated  should your Eclipse ever become lost or stolen  simply provide  Bullard with a copy of a police report  and we can flag that serial number  If the  imager is ever returned to Bullard for service or upgrade  you will be notified           NOTE    Do not connect your Eclipse Thermal Imager to your computer until  prompted to do so during installation of the Eclipse Control Panel software   Failure to observe this practice may result in the installation of defective  USB drivers     Installing the Software    If you turn on your Eclipse prior to
    