5069-IN004 - Rockwell Automation

image

Contents

1. Disconnect Wires from the Removable Terminal Block WARNING If you connect or disconnect wiring while power is applied an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Disconnect wires from the RTB RTB Type Action Screw 1 Turn the screwdriver counter clockwise to open the terminal 2 Remove the wire Spring 1 Insert and hold a screwdriver in the right side terminal 2 Remove the wire 3 Pull out the screwdriver 5069 RTB18 SCREW RTB 5069 RTB18 SPRING RTB Rockwell Automation Publication 5069 INOO4A EN P October 2015 11 5069 Compact 1 0 Digital 16 point Sinking Input Modules Wiring Diagram The following is an example wiring diagram The example applies to both of the 5069 IB16 and 5069 IB16F digital input modules Connections to an external power supply that EN provides SA Power via the SA Power RTB on DC the 5069 AEN2TR EtherNet IP adapter or 5069 FPD field potential distributor IMPORTANT The 5069 1B16 and 5069 IB16F module inputs use a shared common The inputs have a return through internal module circuitry to the SA terminal on the SA Power RTB For more information see page 7 Power the 5069 Compact UO System After you install all 5069 Compact I O modules you can turn on MOD power and if used SA power t
2. 16 point Sinking Input Modules 2 Ifan end cap is installed on the right most module that is installed in the system remove it and keep for later use ATTENTION Do not discard the end cap Use this end cap to cover the exposed interconnections on the last module on the DIN rail Failure to do so could result in equipment damage or injury from electric shock 3 Confirm that the DIN rail latch is closed 4 Ifthe DIN rail latches are open gently push the rear latch back until the front latch pops up and clicks Closed Position gt gt Open Position Re a GA c status H 4 ss 3 a Sy 5 Align the interlocking pieces of the module with the device on the left The top interlocking pieces engage first 6 Push the module toward the DIN rail until a click indicates that the module is locked in place Top Interlocking Pieces 7 Verify that the module is installed in one of the following ways e Ifthe module is installed on the 5069 AEN2TR adapter the front of the 5069 Compact I O module is set back slightly from the front of the 5069 AEN2TR adapter e Ifthe module is installed on a 5069 Compact I O module the fronts of both modules are flush with each other Rockwell Automation Publication 5069 INOO4A EN P October 2015 9 5069 Compact 1 0 Digital 16 point Sinking Input Modules Install the End Cap You must install
3. The enclosure must have suitable flame retardant properties to prevent or minimize the spread of flame complying with a flame spread rating of 5VA or be approved for the application if nonmetallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications In addition to this publication see the following e Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 for more installation requirements NEMA Standard 250 and EN IEC 60529 as applicable for explanations of the degrees of protection provided by enclosures Table 2 North American Hazardous Location Approval The following information applies when operating this equipment in hazardous locations Products marked CL I DIV 2 GP A B C D are suitable for use in Class Division 2 Groups A B C D Hazardous Locations and nonhazardous locations only Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code When combining products within a system the most adverse temperature code lowest T number may be used to help determine the overall temperature code of the system Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time
4. belirlenmi amac n d nda kullan l rsa ekipman taraf ndan sa lanan koruma bozulabilir WAH CH BOE BERERE Em EARI TS APAR EERME ament AE Zigar MARTA OAPI EEZOR o D i 90 HIE BEA ABR SIRS AMEE SB TE A E D HCA IRA A ET Um a A BE RIL WU RAS a AFD eS AE BS EY FP P Ae PR THE HS ko SCR POZOR Nez za nete instalovat konfigurovat i provozovat tento v robek nebo prov d t jeho dr bu p e t te si tento dokument a dokumenty uveden v sti Dodate n zdroje ohledn instalace konfigurace a provozu tohoto za zen U ivatel se musej vedle po adavk v ech relevantn ch vyhl ek z kon a norem nutn sezn mit tak s pokyny pro instalaci a elektrick zapojen innosti zahrnuj c instalaci nastaven uveden do provozu u v n mont demont a dr bu mus vykon vat vhodn pro kolen person l v souladu s p slu n mi prov d c mi p edpisy Pokud se toto za zen pou v zp sobem neodpov daj c m specifikaci v robce m e b t naru ena ochrana kterou toto za zen poskytuje UWAGA Przed instalacj konfiguracj u ytkowaniem lub konserwacj tego produktu nale y przeczyta niniejszy dokument oraz wszystkie dokumenty wymienione w sekcji Dodatkowe r d a omawiaj ce instalacj konfiguracj i procedury u ytkowania tego urz dz
5. d d d d d m HI m d m Ground Considerations You must ground DIN rails according to the Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 DIN rail materials for example aluminum or plastic that can corrode oxidize or are poor conductors can result in improper or intermittent grounding Secure DIN rail to mounting surface approximately every 200 mm 7 8 in and use end anchors appropriately Be sure to ground the DIN rail properly Refer to Industrial Automation Wiring and Grounding Guidelines Rockwell Automation publication 1770 4 1 for more information V ATTENTION This product is grounded through the DIN rail to chassis ground Use zinc plated yellow chromate steel DIN rail to assure proper grounding The use of other You can use the following DIN rails with a 5069 Compact I O system e ENS50022 35 x 7 5 mm 1 38 x 0 30 in e ENS50022 35x 15 mm 1 38 x 0 59 in 6 Rockwell Automation Publication 5069 INO04A EN P October 2015 5069 Compact 1 0 Digital 16 point Sinking Input Modules System Power Considerations The 5069 AEN2TR EtherNet IP adapter provides power to a 5069 Compact I O system through the following e Module MOD power System side power that is required to operate the 5069 Compact I O system MOD power is provided through the MOD power RTB and passed across the MOD power bus e Sensor Actuator SA power Field side power that is used to power field side devices
6. di installare configurare ed utilizzare il prodotto o effettuare interventi di manutenzione su di esso leggere il presente documento ed i documenti elencati nella sezione Altre risorse riguardanti l installazione la configurazione ed il funzionamento dell apparecchiatura Gli utenti devono leggere e comprendere le istruzioni di installazione e cablaggio oltre ai requisiti previsti dalle leggi codici e standard applicabili Le attivit come installazione regolazioni utilizzo assemblaggio disassemblaggio e manutenzione devono essere svolte da personale adeguatamente addestrato nel rispetto delle procedure previste Qualora l apparecchio venga utilizzato con modalit diverse da quanto previsto dal produttore la sua funzione di protezione potrebbe venire compromessa D KKAT Bu r n n kurulumu yap land r lmas i letilmesi veya bak m ncesinde bu dok man ve bu ekipman n kurulumu yap land r lmas ve i letimi ile ilgili lave Kaynaklar b l m nde yer listelenmi dok manlar okuyun Kullan c lar y r rl kteki t m y netmelikler yasalar ve standartlar n gereksinimlerine ek olarak kurulum ve kablolama talimatlar n da renmek zorundad r Kurulum ayarlama hizmete alma kullanma par alar birle tirme par alar s kme ve bak m gibi aktiviteler sadece uygun e itimleri alm ki iler taraf ndan y r rl kteki uygulama y netmeliklerine uygun ekilde yap labilir Bu ekipman retici taraf ndan
7. if necessary SA power is provided through the SA power RTB and passed across the SA power bus A 5069 FPD field potential distributor can also provide SA power to a 5069 Compact I O system IMPORTANT We recommend that you use separate external power supplies for MOD power and SA power respectively This practice can prevent unintended consequences that can result if you use one supply If you use separate external power supplies the loss of power from one external power supply does not affect the availability of power from the other supply For example if separate external power supplies are used and SA power is lost MOD power remains available for the 5069 Compact 1 0 modules For more information on MOD power and SA power see the following e EtherNet IP Communication Modules in Logix5000 Control Systems User Manual publication ENET UM004 e 5000 Series Digital I O Modules User Manual publication 5000 UM004 e 5069 Compact I O Modules Specifications Technical Data publication 5069 TDO001 Installation Summary Complete these tasks to install the module Install the Removable Terminal Block Install the Module Install the End Cap Wire the Removable Terminal Block Vi ve WO N Power the 5069 Compact I O System Rockwell Automation Publication 5069 INOO4A EN P October 2015 7 5069 Compact 1 0 Digital 16 point Sinking Input Modules Install the Removable Terminal Block WARNING If you connect or disconnec
8. pa34ene ononHuTenbHble pecypcbi Bam AOKYMEHTAX N3NOKEHbI CBEEHMA 06 ycTaHOBKe Hactpo ke n kcnnyaTaynn gaHHoro OOopyAoBaHua Monb3oBaTenn OOAZaHbI O3HAKOMMTDCA C NHCTPYKUMAMN NO yCTAHOBKe n NPOKNagKe COeAUHEHM a TAKKE C TpeboBannamn Pre MPMMeHMMBIX HOPM 3aKOHOB H CTAHAApTOB Bce geiicrBua Bkniouaa yCTaHOBKy HanaAKY BBOA B IKCNNYATALNIO UCNONb3OBaHue c6opky pa36opky v TeEXHNYeCKOE ocnyknBaHne AONXKHbI BbINOIHATbCA o6y4eHHbIM NepCOHANOM B COOTBETCTBUM C DDWMGHH MIMI HODMAMM n npaBnnamn Fo o6opygoBanne ncnonb3yeTca He NpegyCMOTpeHHbIM NpOn3BOAnTeneM 0 pa30M 3alTa 0 OpYAOBAHMA MOXKET ObITb HapyleHa 7 ZE AM ut EES fe SE kb LOA RO RIE BE PREIS OVC RR ORS D i CHK UC SIC H e TLES SOFIE Te CORAT SRB TER Dom Ju RER LC Co dm one 9 LC E bn EF DE oe SC Mm MLC HRA RFR MATS erie CHES CaM Ze SENT To OZER AR RIT ST 6 DBR HOES ASB ai DS Bis 2 CEO HE since TIE CHE SI CWS BWA DEEL LOSI CWSI RDN EEN SY ET ACHTUNG Lesen Sie Ges SE und die im Abschnitt Literaturverweise genannten Dokumente zur Installation Konfiguration und Bedienung dieser Ausr stung sorgf ltig durch bevor Sie dieses Produkt installieren konfigurieren bedienen oder instandsetzen Benutzer m ssen sich mit den Anweisungen zur Installation und Verdrahtung vertraut machen und m ssen die Anforderungen aller geltenden Vorschriften Gesetze und Normen kennen Aktivit ten wie Installation Einstellung Inbetriebnahme Verwendung Montage Demontage und Instand
9. suitability for Class Division 2 AVERTISSMENT RIQUE D EXPLOSION e Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher l quipement e Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher les connecteurs Fixer tous les connecteurs externes reli s cet quipement l aide de vis loquets coulissants connecteurs filet s ou autres moyens fournis avec ce produit e La substitution de composants peut rendre cet quipement inadapt une utilisation en environnement de Classe Division 2 e S assurer que l environnement est class non dangereux avant de changer les piles Are Equipment Group Il Equipment Category 3 and comply with the Essential Health and Safety Requirements relating to the design and construction of such equipment given in Annex II to Directive 94 9 EC See the EC Declaration of Conformity at http www rockwellautomation com products certification for details The type of protection is Ex nA IICT4 Gc according to EN 60079 15 e The 5069 IB16 and 5069 IB16F modules comply to standards EN 60079 0 2012 A11 2013 EN 60079 15 2010 reference certificate number DEMKO 15 ATEX 1484X Are intended for use in areas in which explosive atmospheres caused by gases vapors mists or air are unlikely to occur or are likely to occur only infrequently and for short periods Such locations correspond to Zone 2 classi
10. Installation Instructions Allen Bradley 5069 Compact 1 0 Digital 16 point Sinking Input Modules Catalog Numbers 5069 1B16 5069 1B16F Topic Page About the Module 5 Before You Begin 5 Required Components 5 Installation Summary 7 Install the Removable Terminal Block 8 Install the Module 8 Install the End Cap 10 Wire the Removable Terminal Block 10 Disconnect Wires from the Removable Terminal Block 11 Wiring Diagram 12 Power the 5069 Compact 1 0 System 12 Remove the Module 13 Replace the Module 13 Module Specifications 14 Additional Resources 15 Product Overview The 5069 IB16 and 5069 IB16F digital 16 point sinking input modules detect input transitions on field devices That is the modules detect when an input changes state from OFF to ON or from ON to OFF The input modules convert input state transition signals to the appropriate logic level used in the controller 5069 Compact I O modules use the Producer Consumer communication model The Producer Consumer communication model is an intelligent data exchange between modules and other system devices in which each module produces data without first being polled 5069 Compact I O systems are used with some Logix5000 controllers and configured with the Studio 5000 Logix Designer application For more information on how which Logix5000 controllers and Logix Designer application versions are compatible with 5069 Compact I O mod
11. O system see the 5069 Compact I O EtherNet IP Adapter Installation Instructions publication 5069 IN003 You can install the module next to any 5069 Compact I O module Required Components To install the module you need the physical components that are listed in Table 7 Table 7 Components Needed for 5069 Compact 1 0 Module Installation Component Removable terminal blocks Backplane end cap Description One of the following RTB types 5069 RTB18 SPRING RTB 5069 RTB18 SCREW RTB IMPORTANT You must order RTBs separately RTBs do not ship with 5069 Compact 1 0 modules We recommend that you order only the RTB type that your system requires A backplane end cap ships with the 5069 AEN2TR EtherNet IP adapter Tools The following tools are needed e Screwdriver e Wire stripper e Wires For more information on available wire sizes and wire insulation stripping length see Module Specifications on page 14 Rockwell Automation Publication 5069 INOO4A EN P October 2015 5 5069 Compact 1 0 Digital 16 point Sinking Input Modules Dimensions 25 56 mm e beach gt IMPORTANT The 1 01 in SS dimensions for the 2mm 5069 IB16F module 0 87 in Lil 105 42mm s are the same as those 4 15 in shown here DU status Li H i E 137 85 mm 5 43 in d d m m
12. an end cap on the last module in your 5069 Compact I O system 1 Align the end cap with the interlocking pieces on the module 2 Push the end cap toward the DIN rail until it locks in place Interlocking Pieces End Cap Wire the Removable Terminal Block WARNING If you connect or disconnect wiring while power is applied an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding 1 Confirm that MOD power and all sources of SA power are turned off 2 Strip insulation from the wires that you connect to the RTB RTB Type Action Strip12 mm 0 47 in of insulation from the wires Spring Strip 10 mm 0 39 in of insulation from the wires 10 Rockwell Automation Publication 5069 INO04A EN P October 2015 5069 Compact 1 0 Digital 16 point Sinking Input Modules 3 Connect the wire to the terminal RTB Type 1 Insert the wire into the terminal 2 Turn the screwdriver to close the terminal on the wire Torque the screw to 0 4 Nem 3 5 Ibein Push the wire into the terminal If the wire is too thin crimp a wire ferrule on the wire and insert it 7 i lt e G SE 1 Lia 5069 RTB18 SPRING RTB Gs Lin Kb s Ge Gin Spring 5069 RTB18 SCREW RTB Oooo oa ol l
13. bed in this publication use these resources Resource Description 5000 Series Digital 1 0 Modules User Manual publication 5000 UM004 Describes how to use the 5069 Compact 1 0 digital 1 0 modules 5069 Compact 1 0 Modules Specifications Technical Data publication 5069 TD001 Provides 5069 Compact 1 0 module specifications Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 Provides general guidelines for installing a Rockwell Automation industrial system Product Certifications website http www ab com Provides declarations of conformity certificates and other certification details You can view or download publications at http www rockwellautomation com literature To order paper copies of technical documentation contact your local Allen Bradley distributor or Rockwell Automation sales representative Rockwell Automation Publication 5069 INOO4A EN P October 2015 15 Rockwell Automation maintains current product environmental information on its website at http www rockwellautomation com rockwellautomation about us sustainability ethics product environmental compliance page Allen Bradley Compact 1 0 Logix5000 Rockwell Software Rockwell Automation and Studio 5000 Logix Designer are trademarks of Rockwell Automation Inc EtherNet IP is a trademark of ODVA Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Rockwell Otomasyon Ticaret A S Kar P
14. ci n y cableado y con los requisitos de todos los c digos leyes y est ndares vigentes IS KE a El personal debidamente capacitado debe realizar las actividades relacionadas a la instalaci n ajustes puesta en servicio uso ensamblaje desensamblaje y mantenimiento de conformidad con el c digo de pr ctica aplicable Si este equipo se usa de una manera no especificada por el fabricante la protecci n provista por el equipo puede resultar afectada ATEN O Leia este e os demais documentos sobre instala o configura o e opera o do equipamento que est o na se o Recursos adicionais antes de instalar configurar operar ou manter este produto Os usuarios devem se familiarizar com as instru es de instala o e fia o al m das especifica es para todos os c digos leis e normas aplic veis necess rio que as atividades incluindo instala o ajustes coloca o em servi o utiliza o montagem desmontagem e manuten o sejam realizadas por pessoal qualificado e especializado de acordo com o c digo de pr tica aplic vel Caso este equipamento seja utilizado de maneira n o estabelecida pelo fabricante a prote o fornecida pelo equipamento pode ficar prejudicada BHUMAHME epeq Tem Kak ycTaHaBnuBaTb HacTpanBaTb IKCNNYATNPOBATb MNN OOcAYKUBaTb age OOopyAOBaHne NpOYNTA TE 3TOT AOKYMEHT M AOKYMEHTbI NepeyvicneHHble B
15. enia U ytkownicy maj obowi zek zapozna sie z instrukcjami dotycz cymi instalacji oraz oprzewodowania jak r wnie z obowi zuj cymi kodeksami prawem i normami Dzia ania obejmuj ce instalacj regulacj przekazanie do u ytkowania u ytkowanie monta demonta oraz konserwacj musz by wykonywane przez odpowiednio przeszkolony personel zgodnie z obowi zuj cym kodeksem post powania Je li urz dzenie jest u ytkowane w spos b inny ni okre lony przez producenta zabezpieczenie zapewniane przez urz dzenie mo e zosta ograniczone OBS L s detta dokument samt dokumentet som st r listat i avsnittet vriga resurser om installation konfigurering och drift av denna utrustning innan du installerar konfigurerar eller b rjar anv nda eller utf ra underh llsarbete p produkten Anv ndare m ste bekanta sig med instruktioner f r installation och kabeldragning f rutom krav enligt g llande koder lagar och standarder tg rder som installation justering service anv ndning montering demontering och underh llsarbete m ste utf ras av personal med l mplig utbildning enligt l mpligt bruk Om denna utrustning anv nds p ett s tt som inte anges av tillverkaren kan det h nda att utrustningens skyddsanordningar f rs tts ur funktion LET OP Lees dit document en de documenten die genoemd worden in de paragraaf Aanvullende informatie over de installatie configuratie en bediening van deze apparatuur voordat u dit
16. er Passthrough 9 55 A 18 32V DC SA Power 200 mA 10 32V DC SA Power Passthrough 9 95 A 10 32V DC Do not exceed 10A MOD or SA Power Passthrough current draw Isolation voltage 300V continuous Basic Insulation Type No isolation between SA power and input ports No isolation between individual input ports Wire size 5069 RTB18 SCREW connections 0 5 1 5 mm 22 16 AWG solid or stranded shielded copper wire rated at 105 C 221 F or greater 3 5 mm 0 14 in max diameter including insulation single wire connection only 5069 RTB18 SPRING connections 0 5 1 5 mm 22 16 AWG solid or stranded shielded copper wire rated at 105 C 221 F or greater 2 9 mm 0 11 in max diameter including insulation single wire connection only Insulation stripping length 5069 RTB18 SCREW connections 12 mm 0 47 in 5069 RTB18 SPRING connections 10 mm 0 39 in RTB torque specifications 5069 RTB18 SCREW RTB only 0 4 N m 3 5 Ib in DIN rail Compatible zinc plated yellow chromate steel DIN rail You can use the following DIN rail sizes e EN50022 35 x 7 5 mm 1 38 x 0 30 in e EN50022 35 x 15 mm 1 38 x 0 59 in North American Temp Code T4 ATEX Temp Code T4 IECEx Temp Code T4 14 Rockwell Automation Publication 5069 IN004A EN P October 2015 5069 Compact 1 0 Digital 16 point Sinking Input Modules Additional Resources For more information on the products that are descri
17. fication according to ATEX directive 1999 92 EC Rockwell Automation Publication 5069 INOO4A EN P October 2015 3 5069 Compact 1 0 Digital 16 point Sinking Input Modules Table 4 IEC Hazardous Location Approval The following applies to products with IECEx certification Such modules Are intended for use in areas in which explosive atmospheres caused by gases vapors mists or air are unlikely to occur or are likely to occur only infrequently and for short periods Such locations correspond to Zone 2 classification to IEC 60079 0 The type of protection is Ex nA IICT4 Gc according to IEC 60079 15 The 5069 IB16 and 5069 IB16F modules comply to standards IEC 60079 0 6th Edition IEC 60079 15 4th Edition reference IECEx certificate number IECEx UL 15 0055X WARNING Special Conditions for Safe Use This equipment is not resistant to sunlight or other sources of UV radiation This equipment shall be mounted in an ATEX IECEx Zone 2 certified enclosure with a minimum ingress protection rating of at least IP54 as defined in EN IEC 60529 and used in an environment of not more than Pollution Degree 2 as defined in EN IEC 60664 1 when applied in Zone 2 environments The enclosure must be accessible only by the use of a tool This equipment shall be used within its specified ratings defined by Rockwell Automation Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140 of
18. ide power is removed We strongly recommend that you take the appropriate actions to prevent unintended consequences that can result from a system power shutdown before removing MOD power and SA power 2 Ifnecessary remove the end cap from the right side of the module 3 If desired disconnect wires from the RTB as described on page 11 4 Press the DIN rail latch down until it clicks and let go of the latch 5 Pull the module off the DIN rail Alen Bradiey Replace the Module To replace the module follow the steps that are described beginning at Installation Summary on page 7 Rockwell Automation Publication 5069 IN004A EN P October 2015 13 5069 Compact 1 0 Digital 16 point Sinking Input Modules Module Specifications The following table lists a subset of the module specifications For a complete list of specifications see the 5069 Compact I O Modules Specifications Technical Data publication 5069 TD001 Table 8 5069 1B16 and 5069 1B16F Digital Input Module Specifications Attribute Value Temperature operating 0 60 C 32 140 F 1EC60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat JEC 60068 2 14 Test Nb Operating Thermal Shock Temperature surrounding air max 60 C 140 F Enclosure type rating None open style Voltage and current ratings Input ratings 4mA per channel 10 32V DC MOD Power 75 mA 18 32V DC MOD Pow
19. laza Is Merkezi E Blok Kat 6 34752 erenk y stanbul Tel 90 216 5698400 www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation NV Pegasus Park De Kleetlaan 12a 1831 Diegem Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication 5069 INOO4A EN P October 2015 PN 324617 Copyright 2015 Rockwell Automation Inc All rights reserved Printed in the U S A
20. o the 5069 Compact I O system The 5069 AEN2TR EtherNet IP adapter provides power to the system For more information see System Power Considerations on page 7 o Input Channel 0 100 Input Channel 1 101 2 wire Input Channel 2 102 Sensor Input Channel 3 103 Input Channel 4 104 Input Channel 5 105 3 wire Sensor Input Channel 6 106 Input Channel 7 107 Input Channel 8 108 Input Channel 9 109 Input Channel 10 110 Input Channel 11 111 Input Channel 12 112 Input Channel 13 113 Input Channel 14 114 Input Channel 15 115 No Connect No Connect 12 Rockwell Automation Publication 5069 INO04A EN P October 2015 D O status 5069 1816 5069 Compact 1 0 Digital 16 point Sinking Input Modules Remove the Module ATTENTION Do not remove or replace the module while power is applied Interruption of the backplane can result in unintentional operation or machine motion 1 Confirm that MOD power and all sources of SA power are turned off IMPORTANT Before you remove power from the MOD power RTB and if used SA power RTB consider the effect on your 5069 Compact 1 0 system When you remove MOD power and SA power from the 5069 AEN2TR EtherNet IP adapter you shut down power to all 5069 Compact I 0 modules in the system That is all system side and field s
21. of installation Informations sur l utilisation de cet quipement en environnements dangereux Les produits marqu s CL I DIV 2 GP A B C D ne conviennent qu une utilisation en environnements de Classe Division 2 Groupes A B C D dangereux et non dangereux Chaque produit est livr avec des marquages sur sa plaque d identification qui indiquent le code de temp rature pour les environnements dangereux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes a inspection par les autorit s locales qualifi es au moment de l installation WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous e Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous Secure any external connections that mate to this equipment by using screws sliding latches threaded connectors or other means provided with this product e If this product contains batteries they must be changed only in an area known to be nonhazardous Table 3 European Hazardous Location Approval cE Zo 113 G Such modules The following applies to products marked Substitution of components may impair
22. product installeert configureert bediend of onderhoudt Gebruikers moeten zich vertrouwd maken met de installatie en de bedradingsinstructies naast de vereisten van alle toepasselijke regels wetten en normen Activiteiten zoals het installeren afstellen in gebruik stellen gebruiken monteren demonteren en het uitvoeren van onderhoud mogen uitsluitend worden uitgevoerd door hiervoor opgeleid personeel en in overeenstemming met de geldende praktijkregels Indien de apparatuur wordt gebruikt op een wijze die niet is gespecificeerd door de fabrikant dan bestaat het gevaar dat de beveiliging van de apparatuur niet goed werkt 2 Rockwell Automation Publication 5069 IN004A EN P October 2015 Table 1 Environment and Enclosure 5069 Compact 1 0 Digital 16 point Sinking Input Modules ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category Il applications as defined in IEC 60664 1 at altitudes up to 2000 m 6562 ft without derating This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such environments This equipment is supplied as open type equipment for indoor use It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts
23. rtified for use only within the surrounding air temperature range of 0 60 C 32 140 F The equipment must not be used outside of this range Use only a soft dry anti static cloth to wipe down equipment Do not use any cleaning agents Any illustrations charts sample programs and layout examples shown in this publication are intended solely for the purposes of example Since there are many variables and requirements associated with any particular installation Rockwell Automation does not assume responsibility or liability for actual use based upon the examples shown in this publication Rockwell Automation Publication 5069 INO04A EN P October 2015 About the Module Module Status Indicator Before You Begin 5069 Compact 1 0 Digital 16 point Sinking Input Modules DIN rail latch lt lop Interlocking Piece DE INPUT D status 5069 1816 H a HIR Handle MOD Power Bus and SA Power Bus Connectors isolated from each other internally Bottom lt _ Interlocking Piece RTB Lower Tab Before you install the module you must install a 5069 Compact I O system At minimum the system must include a 5069 AEN2TR EtherNet IP adapter and backplane end cap For more information on how to install a 5069 Compact I
24. setzung m ssen durch ausreichend geschultes Personal in bereinstimmung mit den geltenden Durchfiihrungsvorschriften ausgef hrt werden Wenn diese Ausr stung in einer Weise verwendet wird die nicht vom Hersteller angegeben wurde kann der von der Ausr stung bereitgestellte Schutz beeintr chtigt sein ATTENTION Lisez ce document et les documents list s dans la section Ressources compl mentaires relatifs a l installation la configuration et le fonctionnement de cet quipement avant d installer configurer utiliser ou entretenir ce produit Les utilisateurs doivent se familiariser avec les instructions d installation et de c blage en plus des exigences relatives aux codes lois et normes en vigueur Les activit s relatives a l installation le r glage la mise en service l utilisation l assemblage le d montage et l entretien doivent tre r alis es par des personnes form es selon le code de pratique en vigueur Si cet quipement est utilis d une fa on qui n a pas t d finie par le fabricant la protection fournie par l quipement peut tre compromise o NE dal 8B As TE RA 8S7 Mol E EMS zH Mal MY D ASol He A Ae AMO EMSS HENA AT SKIAS ASAE SEH Ke HT 2 REO oda AFA Chel BEE Al A GEZEI dai GG SKlsHOr SI Mal zg JS MS 2B Sai SAS S SETHE AH Pol het He WSs HS ASAS Soot SHH SI E YHE MAA Out SES SHOR ASA YHo Ss Jl50 AAS ASIC ATTENZIONE Prima
25. t the removable terminal block RTB with power applied an electrical arc can occur This could cause an explosion in hazardous location installations The removable terminal block RTB does not support Removal and Insertion Under Power RIUP capability Do not connect or disconnect the removable terminal block RTB while power is applied Be sure that power is removed before proceeding 1 Hook the bottom of the RTB on the module 2 Push the RTB against the module until the RTB clicks into place 3 Push the RTB handle against the RTB until you hear another click Install the Module WARNING If you insert or remove the module while backplane power is on an electrical arc can occur This could cause an explosion in hazardous location installations The module does not support Removal and Insertion Under Power RIUP capability Do not connect or disconnect the module while power is applied Be sure that power is removed before proceeding 1 Confirm that MOD power and all sources of SA power are turned off In addition to the risks described in the previous table that exist because the module does not support RIUP if you remove the module with power applied the system MOD power bus and SA power bus are affected For example you can interrupt MOD power to the other modules in the system Unintended consequences can occur as a result 8 Rockwell Automation Publication 5069 INO04A EN P October 2015 5069 Compact 1 0 Digital
26. the rated voltage when applied in Zone 2 environments The instructions in the user manual shall be observed This equipment must be used only with ATEX IECEx certified Rockwell Automation backplanes Secure any external connections that mate to this equipment by using screws sliding latches threaded connectors or other means provided with this product Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous Earthing is accomplished through mounting of modules on rail Devices shall be used in an environment of not more than Pollution Degree 2 Table 5 Prevent Electrostatic Discharge ATTENTION This equipment is sensitive to electrostatic discharge which can cause internal damage and affect normal operation Follow these guidelines when you handle this equipment Touch a grounded object to discharge potential static Wear an approved grounding wriststrap Do not touch connectors or pins on component boards Do not touch circuit components inside the equipment Use a static safe workstation if available Store the equipment in appropriate static safe packaging when not in use Table 6 Electrical Safety Considerations ATTENTION IMPORTANT Do not wire more than 1 conductor on any single RTB terminal In case of malfunction or damage no attempts at repair should be made The module should be returned to the manufacturer for repair Do not dismantle the module This equipment is ce
27. ules see the publications listed in Additional Resources on page 15 Allen Bradley Rockwell Software Rockwell Automation 5069 Compact 1 0 Digital 16 point Sinking Input Modules ATTENTION Read this document and the documents listed in the Additional Resources section about installation configuration and operation of this equipment before you install configure operate or maintain this product Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes laws and standards Activities including installation adjustments putting into service use assembly disassembly and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired ER ERR ACR BAPE AE AS a ml SC RU PR INA CAR EA OCS PRY ri I E Funk ZI FEL Bs GAS At E eae TARE PU EPA 03 PRU AED SE RE D 2 HZ a es AR Se A Pe EE FER ESS i o Ju RAR Ta FR tl ie AS ET A UAT BE SE RE RD ATENCI N Antes de instalar configurar poner en funcionamiento o realizar el mantenimiento de este producto lea este documento y los documentos listados en la secci n Recursos adicionales acerca de la instalaci n configuraci n y operaci n de este equipo Los usuarios deben familiarizarse con las instrucciones de instala