Home

Jx-Series-UM WIP - Janak Healthcare

image

Contents

1.
2. HEALTHCARE Examination Couch Motorized Jx Series User s Manual Index 1 Introduction 2 About this Product 3 Definitions 4 Safety 5 Environmental Specifications 6 Installation amp Operation Jx2000 7 Installation amp Operation Jx4000 4001 8 Maintenance amp Cleaning 9 Warranty amp Service TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 INTRODUCTION About this Product A These examination couches and tables are non invasive medical devices used for the patients to lie down for examination treatment by doctor medical paramedical hospital personnel B These examination couches and tables are patient support and patient rest facility which help medical experts n carrying out their medical procedures comfortably C The examination couches and tables are manufactured and supplied in non sterile condition for use in normal hospital environment D These examination couches and tables are not diagnostic measuring monitoring or a therapeutic device or we say that it can prevent or alleviate disease Jx2000 Variable height Motorized Examination Couch helps in convenient mounting of patient Low height helps elderly amp orthopedic patients to mount amp dismount easily High height facilitates the doctor to examine the patient more efficiently The Motorized Examination Couch also facilitates easy general examination User Friendly Hand
3. Janak Healthcare Pvt Ltd reserves the right to change the information in this document without prior notice MANUFACTURER S ADDRESS Corporate Office Janak Healthcare Pvt Ltd Unit No 12 1st Floor Kalpataru Point Opp Cinemax Theatre Sion Circle Sion E Mumbai 400022 Tel 91 22 4915 3000 Fax 91 22 4915 3100 www janakhealthcare com Registered Office Janak Healthcare Pvt Ltd Janak House Opp Indian Oil Corp Depot Sheikh Misry Road Wadala E Mumbai 400037 Tel 91 22 2418 0637 2413 0407 Fax 91 22 2413 9870 Toll Free No 1800 22 8020 Email technicalsupport janakhealthcare com CE TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 145 Notes 16 TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 Notes TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 17 Notes 18 TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 2 JANAK EALTHCARE JANAK HEALTHCARE PVT LTD Unit No 12 1st Floor Kalpataru Point Opp Cinemax Theatre Sion Circle Sion E Mumbai 400022 Tel 91 22 4915 3000 Fax 91 22 4915 3100 www janakhealthcare com
4. Jx Series UserManual Rev No 0 Date 30st October 2014 Plastic Pan e Plastic Pan Paper Roll Holder e Paper Roll Holder is provided on the Backrest Section to keep the Paper Roll Load Bearing Capacity Jx2000 Jx4000 Jx4001 AN 10 TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 Do not load the Jx Series Examination Couches more than the safe working load mentioned above Patient user should not mount or sit or place any heavy load on the backrest section leg section as it may cause toppling With due consideration to environmental limitations materials used to make the device are not affected by contact with any bio chemicals or bio waste When used as per its intended purpose all materials used in the product and accessories do not facilitate any breeding or growth of bio contaminants on their own MAINTENANCE amp CLEANING Maintenance Each time before putting the Jx Series Examination Couch into service the user must check for e Lubrication of all the mechanical joints pins moving parts tightening of the bolts are done properly to avoid unnecessary play sound and wear amp tear of the Jx Series Examination Couch e Visual inspection for any mechanical damage e g loose screws etc Ifany damage or malfunction is observed immediately report this matter to the operator e Ifthe Jx Series Examination Couch is notin use it should be stored in a
5. Series Examination Couch and property e Ensure stabilized and properly earthed input power supply for the equipment Also ensure polarity of the mains socket is as per Standard and matches with the mains plug Inspectallthe wires and cables for any cuts cracks damages at regular intervals ELECTRICAL SPECIFICATIONS ains power supply 90V AC to 300V AC with battery Frequency Protection Voltage ode of operation Power consumption ideal mode without battery Power consumption ideal mode with battery Power consumption at maximum load ains Fuse DC Bus Fuse Protection Class TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 150V AC to 300V AC without battery 50Hz 5Hz 300V to 450V 10 2min In Use 18 min Not in use 5W 10W 300W max 2A fast blow for Mains external 10A fast blow fuse internal Inbuilt Battery Charger Battery Charger Inbuilt ENVIRONMENTAL SPECIFICATIONS Usage Storage and Transport Temperature Relative Humidity Atmospheric Pressure Altitude Protection Degree Installation and Operation Jx2000 Installation 1 Unpack the Jx2000 carefully Suitable to charge 1 3Ahx 2 batteries Reverse polarity protection Spark free connection Short circuit protected output Very minimal battery consumption at idle state to enhance standby time Battery overcharging protection Battery low or dip discharge protection 10 C to 50 C 0 t
6. bring about any change in the structure or adhesive property of the plastic e The Jx Series Examination Couch should be properly cleaned and disinfected at regular intervals to avoid infection and stains e Werecommend use of approved disinfectant and cleaning agents to clean the Jx Series Examination Couch Take extra care to clean areas that may trap dust or dirt All detachable accessories and its component can be cleaned separately Do not expose the Jx Series Examination Couch to excessive moisture as corrosion may cause personal injury or equipment damage Disposal Product and its defective parts especially elements made of plastic steel rubber and electrical material should be disposed off in accordance with the statutory rules and regulations prevailing for such disposal The user is advised to contact Janak Healthcare Pvt Ltd for further assistance 12 TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 JANAK HEALTHCARE Routine Inspection Check List Inspection by the User Recommended Frequency Every new allotment but not later than one month Checks Observation OK NotOK Description of faults Visual check of the electrical components Handset Damage Loose Hanging Mains cable Damage Loose Hanging Control elements Damage Loose Hanging Visual check of the mechanical components Base frame Damage deformation Upholstery Damage Torn Soiled Sc
7. dry and rodent free indoor environment ona flat surface with gradient not more than 5 degrees e If the Ux Series Examination Couch is not in use for long term it is necessary to conduct a test to check for functioning and any mechanical damage that may have been caused Depending on the usage certain moving parts may require replacement due to wear tear We recommend imely replacement with original spares for safety and trouble free operation Mattress upholstery impermeability could be affected by needle sticks Users should be instructed to avoid punctures caused by improper use of needle sticks Failure to do so could result in cross infection amp patient injury The mattress should be regularly inspected for punctures rips tears or other such damage amp replaced with suitable original mattress if required Smoking should be prohibited near the mattress upholstery with without patient as this is a fire hazards and mattress sheets amp pillows generally do not have flame retardant properties TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 11 Cleaning amp Disinfecting e The Jx Series Examination Couch is not suitable for machine wash or steam cleaning Donotuse water jet for cleaning e The Jx Series Examination Couch cannot tolerate the influence of strong solvent basic or alkaline liquids amp caustic agents e The cleaning agents must not contain any substances which
8. external fuse blown off e Battery discharged e Reduce the load Refer Safe Working Load e Replace the fuse e Recharge the battery Backrest not working e Check Alignment of Gas Spring Gas Spring defective damaged e Readjust the Gas Spring Bracket amp Cover e Replace the Gas Spring Abnormal sound vibrations during any operation e Linkages are tight e Nut Bolts loose e Lubricate the Linkages from its joints e Tighten the bolts Unusual burning smell e Check for any short circuit in the Mains wire e Short circuit in the Control Unit e Switch off the mains supply amp Unplug the product from its mains socket amp contact Janak for further assistance TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 WARRANTY amp SERVICE Janak Healthcare Pvt Ltd warrants solely to the end users of this product that for a period specified in the warranty certificate such product shall perform as per its intended use The foregoing warranties shall not apply if the Product has been subjected to a physical abuse misuse abnormal use or use not consistent with Janak Healthcare Pvt Ltd s published directions b any modification by anyone other than Janak Healthcare Pvt Ltd or third parties designated by Janak Healthcare Pvt Ltd or c fraud tampering negligence or accidents depending upon the nature of the products Limitation Of Liability In no event s
9. ement etc who will be responsible for the safe operation of these Jx Series Motorized Examination Couches User User is a person who is capable of assessing clinical condition of patient e g specialist medical personnel doctors nursing staff attendants etc On the basis of their training experience or through the instructions they are entitled to use these Jx Series Examination Couches on their own responsibility or to carry out work on it and are able to recognize and control possible risks to the patient as well as the Jx Series Examination Couches Patient The patient is a person who is ill infirm disabled or in need of medical assistance who needs to be examined SAFETY In this User Manual the following safety symbols are used Danger This symbol will appear wherever safety instructions are designed to protect people from physical harm The symbol stands for imminent danger of death or serious injury Caution This symbol will appear where situations are described which might be dangerous and which might inflict slight injuries Electric Hazard This symbol appears when a life threatening hazard or hazardous condition is likely to occur er Advice This symbol will appear in front of additional helpful pieces of advice e Adotin front of the text implies the action that is required to be taken Safety Instructions e Ensure that the Jx Series Examination Couches are assembled and installed in accordance with the instr
10. hall Janak Healthcare Pvt Ltd be liable or obligated to the end user in any manner for any special non compensatory consequential indirect incidental statutory or punitive damages of any kind including without limitation for injury or loss of life lost profits lost sales lost revenue loss of any software or data or loss of use of any hardware software or data regardless of the form of action whether in contract tort negligence strict product liability or otherwise even if Janak Healthcare Pvt Ltd has been informed of or is aware of the possibility of any such damages in advance Janak Healthcare Pvt Ltd s total aggregate liability under this agreement and in relation to anything which Janak Healthcare Pvt Ltd has done or not done in connection with this agreement shall be limited to the price of the products purchased and paid for by the end user during the period in which such liability arises The limitations set forth above shall be deemed to apply to the maximum extent permitted by applicable law and notwithstanding the failure of the essential purpose of any limited remedies In order to maintain functional safety and right to claim under the warranty only original replacements parts may be used For ordering replacement parts customer service request and further question please contact our technical support department Disclaimer Every effort has been made to ensure that the information in this user manual is valid
11. nts are running on the battery e Red indicator indicates that the battery is fully discharged Battery e The Jx Series Examination Couches are equipped with battery to allow emergency operation of the electric drive system This ensures that all the power adjustment can still be carried out even in the event of power failure The battery also has inbuilt fuse protection for the safety of battery as well as users e Charge the battery for 20 hours and then connect it to the system if the Jx Series Examination Couch has not been in use over a period of one month This may damage the battery e Always keep the Jx Series Examination Couch in charging condition for any emergency use Always keep the Jx Series Examination Couch connected to the main supply to get a fully charged battery e Operations of the Jx Series Examination Couch on Battery should be only as per its Duty cycle refer Electrical Specifications given above Batteries in the Jx Series Motorized Examination Couch may emit hydrogen gas So do not bring fire or a heated object close to the Product TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 Jx4001 Removable Leg Section Removable Leg Section Removable Leg L Section to be inserted in these slots e InJx4001 the Leg Section is removable Hand Grips e Hand Grips Pelvic Tilt Handle e Pelvic Tilt can be adjusted as desired with the help of Handle TF ECT
12. o 95 non condensing 800 to 1060 hPa lt 2000m IP54 2 Ifthe packing is drenched by rain water or other liquids inform this matter to the operator TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 CP Jx2000 comes in aready to use condition Notify if any damage has occurred during transportation either to the authorized agent or directly to Janak Health Care Pvt Ltd A Dispose the packing material waste in accordance with the local waste disposal regulations prevailing Operation A The Height can be operated with the help of Handset provided Press the power button 3 on bottom amp then press the up down button 1 82 on the handset to achieve the desired height Gas Spring Handle B Backrest can be adjusted with the help of Handle fixed on the Gas Spring provided on the backrest section TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 Paper Roll Holder Utility Space C Dual sided Utility space is given as shown in the above figure D Paper roll holder to keep the Paper roll as shown in the above figure Installation and Operation Jx4000 Jx4001 Installation 1 Unpack the JX 4000 4001 carefully 2 Ifthe packing is drenched by rain water or other liquids inform this matter to the operator Each Jx4000 is supplied with the following components as per packing list A Complete Couch with foldable Leg section Jx4000 1 No B Com
13. plete Couch with removable Leg section Jx4001 1 No C Cushioned Lithotomy Crutches 2Nos Notify if any damage has occurred during transportation either to the authorized agent or directly to Janak Health Care Pvt Ltd Installation of the Jx4000 Jx4001 should be done only by Janak trained technicians gt 9 Dispose the packing material waste in accordance with the local waste disposal regulations prevailing TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 Installation Cushioned Lithotomy Crutches Paper Holder Gas Spring Assisted Backrest Flexible Hand Control Plastic Pan with Clam Hand Grips Manually Controlled Pelvic Tilt Foldable Leg Section Well Balanced Base Lithotomy Crutches Star Knob Install the Lithotomy Crutches into its slots provided on both sides amp tighten the same with the help of Star Knobs as shown in the above figure TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 Operation The Height can be operated with the help of Handset provided Press the power button 3 on bottom amp then press the up down button 1 amp 2 onthe handset to achieve the desired height A Handset if dropped can cause malfunctioning of the handset Battery Indicators on Handset e Green indicator on handset shows that the control elements are running on the main supply e Orange indicator indicates that control eleme
14. rews and rivets Loosened Missing Performance check of the electrical components Handset Functional test Control unit Functional test Actuators Functional test Performance check of all mechanical components Backrest Smooth Movement Detachable Lithotomy Crutches Jx4000 Jx4001 Handle Grips Secure retention Drawer Pan Smooth Movement Level Adjust Levelling Screws at Bottom of Base Frame Accessories Fastening Damage Missing Sign Result of inspection Date TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 JANAK HEALTHCARE Trouble Shooting Guide Problem Possible Causes Remedy e No main voltage at mains e Checkinthes ly current Jx2000 Jx4000 Jx4001 Sere ae fi na not working ugin the mains cable e The Mains cable is not pluggedin e Mains fuse blown e Replace the fuse 2A Height function not e Actuator not functioning e Check the Actuator connector for working e Control unit not functioning any loose connection e Handset not functioning e Replace the Actuator e Repair or replace the control unit e Repair or replace the Handset Jx2000 Jx4000 Jx4001 e Battery discharged e Recharge the battery as not functioning during mains power failure e Battery fuse blown off e Battery wire loosened recommended e Replace the fuse Fixthe battery wire firmly Beeping sound from the Control Unit Overloading on the Jx2000 Jx4000 Jx4001 Internal or
15. set helps easy and smooth height adjustment by User Drawer is provided for storage Jx4000 Jx4001 Variable height Gynaec Motorized Examination Couch helps in convenient mounting of pregnant patients mothers Low height helps pregnant patients to mount amp dismount easily High height facilitates the doctor to treat the patient more efficiently User Friendly Handset helps easy and smooth height adjustment by User U Cut helps use of speculum and forceps Lithotomy Crutches helps in lithotomic position and support to lower legs Calf muscles Hand Grip is provided for patient safety and support while the height amp backrest is being adjusted Plastic Panis provided for collection of Placenta Not to be used for storing other medical waste for safety and hygiene of User Foldable Removable Section is provided for easy access of User Jx Series Examination Couches Features Optional Accessories Jx2000 Please refer product catalogue Jx2000 for salient features of this product Jx4000 Jx4001 Please refer product catalogue Jx4000 for salient features of these products Technical Data Jx2000 Please refer product catalogue Jx2000 for Technical Data of this product Jx4000 Jx4001 Please refer product catalogue Jx4000 for Technical Data of these products TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 DEFINITIONS Operator Operator is the person appointed by the owner i e clinic hospital manag
16. uctions given in this User Manual wherever required e Restrict child visitors without proper attendants Supervision is necessary to avoid any mishap due to unintended movement of the Jx Series Examination Couches e Keep some gap between walls and Jx Series Examination Couches while in stationary position and also while moving from one place to another e Keep the User Manual handy with the Operator User for ready reference e Do not allow any visitor to sit on the Jx Series Examination Couches from the Head side as it may cause overloading Refer section operation 2 TF ECT Jx Series UserManual Rev No 0 Date 30st October 2014 e Accessories or any devices used along with Jx series Examination couches should be as per its intended use specified and approved by Janak Healthcare Pvt Ltd e Donotkeep any articles below the table mainframe It can damage the linkages e Patient should be advised not to sit on edge of any section when it is in extended full length position Electrical Safety Points When the Jx Series Examination Couch is connected to 230V 15A or as per country specific main supply Connecting more than one plug to the three pin mains socket can cause electrical overload and damage the control system of the Ux Series Examination Couch e AC power supply exceeding 230V or sudden spikes or lack of proper earthing can be hazardous to User Patient as well as can cause damage to the Jx

Download Pdf Manuals