1. audible alarm and will send an alert message to the Z Wave network if included in the network already Pressing and holding the button for 2 seconds will clear the Water Alarm If freezing conditions are detected no audible alarm will sound but an alert message is sent to the Z Wave network if included in the E 1080 Centre Rd Suite C Phone 248 481 7092 N Auburn Hills MI 48326 sales fortrezz com FORTREZ www fortrezz com Made in USA network Depending on your Z Wave controller it is possible to receive a remote alert For example with some gateway controllers you Can receive an email or cell phone text message when an alarm is activated With a gateway s remote access and depending on your specific controllers capabilities you will be able to check the status of any WWA 01 in your network Choosing a mounting location The WWA 01 is suitable for use in dry interior locations only Avoid placing the WWA 01 close to a metal frame or other metal enclosures that may affect RF range Also avoid areas with rapid temperature swings Place the unit so that any leaks that may occur will not drip directly on the unit Recommended WWA 01 uses Under sink Next to Sump pumps Water Heaters Laundry Room Bathroom Floor Storage Area Garage Utility Sink Vacation Recreation homes Boats etc Low Battery The WWA O01 will broadcast an alert on the Z Wave network at regular intervals when it detects a low battery condition In addition
2. it will periodically sound an audible chirp Your controller may be able to be configured to monitor the WWA 01 wake up notifications If these stop then this might be an indication that the battery has died or that transmissions from the WWA 01 are no longer be received Because the audible water alarm draws a large current from the battery the battery should be replaced each time an actual water leak has been detected After a water leak please ensure that there is no moisture in the unit before replacing the battery Do not install batteries that appear damaged or unsealed When replacing batteries the water seal may be broken around the screws After screwing the parts back together it is recommended to use some sealant such as silicone caulk around the screws FCC Compliance Statement Statements This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Warning Part 15 21 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC Interference Statement Part 15 105 b This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed
3. to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry Canada Statement per Section 4 0 of RSP 100 The term IC before the certification registration number only signifies that the Industry Canada technical specifications were met Section 7 1 5 of RSS GEN Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Limited Warranty THE PRODUCT IS PROVIDED WITH ONE YEAR LIMITED MANUFACTURER WARRANTY FORTREZZ LLC warrants its products to be free from
4. VEC 4 i ay i nstru ct I O n Ma n u al Products that speak A WWA 01 Wireless Water amp Freeze Alarm work together better Thank you for purchasing the WWA 01 Wireless Water amp Freeze Alarm This product will provide you with the peace of mind and protection you expect Leaking pipes corroded water heaters fixtures in bathrooms and laundry rooms refrigerator drip pans etc can all cause water damage The WWA 01 is a Z Wave enabled device and will send a water leak alert on any Z Wave enabled network A WWA 01 unit that is not in a Z Wave network will still alert you to water leaks using the audio alarm Specifications Power One 3 6V 1 2AA 1200mAh Lithium Battery ER14250H LS14250 or equivalent Battery Life Calculated to be 1 to 2 years with no alarms and default Z Wave network settings Frequency Range 908 42MHz US Distance Range Max 100ft line of sight in unobstructed environment Product Size LxWxD 2 4 x 1 6 x 0 8 Product Weight 0 2 Ib Operating Temperature 10 C 14F to 70 C 158F Reported Temperature Reported temperature is at the unit and has a 2 degC accuracy System Requirement Any Z Wave enabled network and controller Testing the WWA 01 Moisten a paper towel and place over both of the small metal pads on the water sensor until you hear the audible alarm sound The water alarm may take up to 4 or 5 seconds before it sounds If the alarm fails to sound your battery may be
5. d listen for commands when in a network press and hold the button for at least 2 seconds The WWA 01 will stay awake for approx 30 seconds Associations Once in a network a controller can be used to associate the WWA 01 with other devices in the Z Wave M network such as a light or another remote audible alarm Refer to your controller s documentation on how to associate the WWA 01 to another device in your network The WWA 01 supports two association groups A maximum of 5 associated devices are allowed in each group The WWA 01 sends the Basic Set Command to the associated nodes assigned to Group1 to convey that a Water Alarm is active If no nodes are assigned to Group 1 then a Binary Sensor Report value OxFF is broadcast The reports are sent at regular intervals while the water alarm is active When the water alarm is cleared via the button one additional report with status no alarm is sent The WWA 01 sends the Basic Set Command to the associated nodes assigned to Group2 to convey that a Freeze Alarm is active If no nodes are assigned to Group 2 then a Binary Sensor Report value OxFF is broadcast The reports are sent at regular intervals while the freeze alarm is active When the freeze alarm is cleared due to temperature rise one additional report with status no alarm is sent Program Switch for inclusion or exclusion During an alarm If water is detected at the monitoring location the unit will sound an 82 decibel
6. defects in material and workmanship under normal use for one year and is not responsible for consequential damages or installation costs of any nature FORTREZZ LLC expressly disclaims all implied warranties including but not limited to the implied warranties of merchantability and fitness for a particular purpose FORTREZZ LLC does not warrant guarantee or make any representations regarding the use or the results of the use of the products or any accompanying materials in terms of their correctness accuracy reliability or otherwise In no event shall FORTREZZ LLC be liable to Purchaser hereunder or in respect of any products ordered or delivered to Purchaser whether in contract tort including negligence or otherwise for a loss of profits or loss of use or for any incidental consequential special or indirect damages howsoever caused whether or not FORTREZZ LLC has been advised of the possibility of such loss or damage FORTREZZ LLC s maximum liability to Purchaser under these conditions shall in no event exceed the amount paid by Purchaser for the products that are the subject of the claim and in respect of all claims for products ordered from FORTREZZ LLC to which these conditions apply to the amount paid by Purchaser for the products which are the subject of the claims If you are not comfortable with your limited warranty or not completely satisfied with the WWA 01 or the WWA 01 does not perform as expected we encourage you to return th
7. e WWA 01 to your DISTRIBUTOR for an exchange or for a full refund within 30 days of purchase Or you can return the WWA 01 to FORTREZZ with an RGA number All products to be returned to FORTREZZ LLC must have a valid Returned Goods Authorization RGA Send the returned unit to FortrezZ LLC Warranty Replacement 1080 Centre Rd Ste C Auburn Hills MI 48326 postage prepaid with a payment of US 9 95 to cover the cost of return shipping postage and handling You must use the original packaging and include a proof of purchase photocopy of receipt along with the RGA and the returned Wireless Water and Freeze Alarm _ 1080 Centre Rd Suite C Phone 248 481 7092 N L Auburn Hills MI 48326 sales fortrezz com FORTREZ www fortrezz com Made in USA
8. old or dead or incorrectly installed the sensor may not be moist enough or the water sensor may be damaged If you do hear the audible alarm remove the moistened paper towel clean the small metal pads of any water residue and hold the button for 2 seconds to clear the alarm You can then add your water alarm to any Z Wave enabled network and controller Examples of Z Wave controllers can be found on the FortrezZ website www fortrezz com Using the WWA 01 in a Z Wave Network reas Oop The button in the rear casing is used for including or excluding the WWA 01 in a Z cts thal speck ZWave Wave network Refer to your controller s User Manual for specific details on SST network inclusion exclusion and association IC 8156A WWAO1 908 MHz Made in USA by a Program FortrezZ LLC Switch www fortrezz com Inclusion in adding to a network 1 Set up the inclusion mode at the controller 2 Press the button or hold the button for approx 2 seconds until the controller indicates the unit has been included in the network Also a beep will be heard when the inclusion completes nclusion and exclusion are always done at normal transmit power mode Exclusion from removing from a network 1 Set up the exclusion mode at the controller 2 Press the button for approx 2 seconds until the controller indicates the unit has been removed from the network A beep will also be heard when the exclusion completes Awake Mode To remain awake an