Home
        SWING Quick User`s Guide (National-1)
         Contents
1.      AEQ    SWING Quick User   s Guide  National 1                                        M  OC 0 hms 3                                                          V35 x21 Startup Config E sy Port     AE Analog ie en  Q  ED   Tel  Line Gui  Ancifary Data                                                                                                            amp  Cgntrol Port  Aux   4W    1  Turning the Equipment On     Before connecting the power supply to the equipment make sure that the Power On  switch  7  is on the OFF position    Once the power supply   s threaded connector is properly connected to the equipment  6    then the power supply can be connected to the outlet    After all previous steps have been completed it is now save to turn on the equipment  using the Power On switch  7   The LCD screen should be on  indicating that all is  working properly     2  Connection to the    U    Interface Jack     Make sure that the DIP micro switch 8 is up  Switch 1 selects between the basic ISDN  standards  up   USA  amp  Canada  down   Europe and other countries   If they are not in  the rigth position  place them in the up position and restart the equipment    In most cases the connection to ISDN will be done through the RJ 11 ANSI connector   1   Use the cable supplied with the equipment to connect it to the    U    interface jack  if  the ISDN jack installed by the ISDN service provider is RJ 45     S    type  please refer to  the User   s Manual for further explanation   
2.    3  Configuring the ISDN Terminal Adapter  In order for the Swing to receive or place any  calls the Terminal Adapter must be configured correctly  this is accomplished by entering  MSN and SPID numbers  in the following manner     Press the Set Up button on the keypad to access the Set Up menu    You will see the    1  ISDN    option on the LCD screen  press the Yes button to enter into  this option and set up the MSN and SPID numbers    Press the     7  keys to navigate between NUMBER LINE 1  NUMBER LINE 2  SPID  Line 1 and SPID Line 2  Press the Yes button to enter into the desired option    NUMBER LINE 1 and 2 are entered by pressing the corresponding numbers from the  keypad  Press the    key to erase any mistakes  Press the Yes button once the number is  correct to save it    Note  the three digit area code should not be included when entering these numbers     AEQ SWING Quick User   s Guide  National 1    Revision 02  07      AEQ    The SPID numbers will be entered in the same way using the keypad  Press the    key to  erase any mistakes  Press the Yes button once the numbers are in correctly to save  them  The ISDN service provider should supply the SPID numbers    The equipment should be restarted at this point  Any changes and entries will be saved  even when the equipment is turn off     4  Choosing a Coding Mode     The Swing usually comes ready to place a call in G 722 Statistical mode  but other  modes can be selected  Press the Coding button on the keypad to 
3.  placed    Press the No button to end the call     6  Using the Analog Line     The swing allows an ISDN communication and an analog communication to be  established simultaneously  or individually if desired  Connect the RJ 11 cable in the  Analog Tel  Line connector  9  on the back of the equipment    Press the button on the keypad  this will connect the phone line and the dial tone  should appear on headphones    Press the Dial Pad button to activate the keypad  this will allow the target phone number  to be entered    Press the    button again to end the call    For other analog line options please refer to the User   s Manual     AEQ SWING Quick User   s Guide  National 1    Revision 02  07    
4. access the list of  coding modes that can be selected    The coding method used on the last call will appear on the LCD screen  By pressing the      7  keys all other methods will be accessed    Note  G 722 and G 711u are the most commonly used  so all other modes can be found  under the ADVANCED option    Press the Yes button to select the coding method desired  The coding method will be  saved even after the equipment is turned off     5  Placing a call on ISDN     Press the ISDN button on the keypad  the LCD screen will show the lines that are  available depending on the coding mode being used  Example  If MPEG128 or LD 2 is  being used  two lines will be available  but in all other modes only one line will be  available    There will be a     gt     over the line on which the call will be placed  the     7  keys allow  movement between the lines  Usually the  gt  will be pointing at the line on which the call  should be placed on    Once the line has been selected press the Yes button  which will allow entering the  targeted phone number  The number will be entered using the keypad  and erasing can  be accomplished by using the    key    Finally  when the targeted phone number is in correctly press the Yes button and the call  will be placed    Note  both the codec that is placing the call and the one that is receiving have to be in  the same coding mode    In 128 modes  the call should be placed on L1 first  then after L1 connects and  synchronizes  the call on L2 can be
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
50Hz - 三菱電機  Rapport final de la Commission fédérale d`enquête  Guía del usuario de la Impresora/ Copiadora  Descargar PDF  EVERDEC W98  Classical Nylon Guitar - Kronos - User Guide  Service Manual    USER MANUAL - YMGI Group  Avis du CESC : La participation citoyenne    Copyright © All rights reserved. 
   Failed to retrieve file