1. CONNECTING ADAPTEC PLUS TO AN ALARM SIREN For all FingerTec door access control models there is a security button behind the terminal During normal operation the security button is compressed and once PA the terminal is dismantled the button will be released gt and a System broken message will appear onscreen During the release of the button the terminal will output an alarm signal However no alarm sound will be emitted if the terminal is not equipped with an external siren To use the siren feature we recommend that you install an additional alarm siren and connect it to the FingerTec terminals Benefits of Using AdapTec Plus with Alarm Siren We recommend that you install a terminal along with AdapTec Plus if you plan to use the alarm siren In AdapTec Plus an additional port is read ily built to receive the alarm signal from the FingerTec terminals AdapTec Plus has an output of 12VDC and it is suitable for use with an alarm siren that has the same power input You do not need to source an additional 12VDC power supply for this purpose Furthermore AdapTec Plus comes with a Siren Mute button where you can press the button to deactivate the alarm siren when required WIRING DIAGRAMS ALARM SIREN R2 Kadex m Kadex H2i and Face ID3 Siren Exit Mute Switch Siren Mute Button Remark AdapTec Plus Tamper Siren EM 12V ov Switch Out Lock Out e Set Auto Alarm in terminal to N
2. e Menu gt Options gt Sys Opt gt Adv Opt gt Auto Alarm gt N WIRING DIAGRAMS ALARM SIREN AC900 AdapTec Plus fo Tamper Siren EM 12V ov Switch Out Lock Out Siren Exit Siren Mute Button Remark e Set Auto Alarm in terminal to N e Menu gt Options gt Sys Opt gt Adv Opt gt Auto Alarm gt N WIRING DIAGRAMS ALARM SIREN Face ID 2 Q2i and i Kiosk 100 Plus AdapTec Plus Siren Exit Lor oo Siren Mute Button Deactivating the Alarm Siren 1 At the terminal press Menu and select Turn Off Alarm to turn off the alarm siren 2 To deactivate the alarm siren of Adaptec Plus press the Siren Mute Button that is connected to the Adaptec Plus This will turn off the alarm siren function in the Adaptec Plus UNDERSTANDING ADAPTEC PLUS INSTALLATION FOR e Wooden Door or Glass Door The diagrams below only highlights the use of an EM lock during installa tion You may opt to use a dropbolt deadbolt door strike instead Please consult a qualified technician installer before proceeding with the instal lation Screws 4 feet 1 2 meter recommended Toinstall FingerTec AC900 R2 on a wall drill 5 holes as shown 4 small holes are for the screws and the bigger hole is for the network cable Tighten the 4 screws to fix the Back Steel Plate on the wall Install the keyswitch as per instructions given in the box The keyswitch is an over
3. signal to work with the AdapTec Plus to setup a door lock system i Kiosk 100 Plus Face ID 2 Face ID 3 Convenient Installation See diagram 1 page 8 for details Secure Installation See diagram 2 page 8 for details Step 4 Connect the wires from AdapTec Plus to the door lock system See diagram 1 page 8 for details Ignore this Step Q Look for the power input port on the FingerTec terminal Normally the con nection ports on the terminals are marked as PWR 12V red wire and GND black wire Step 2 Convenient Installation Look for the door lock output port NO and GND from the terminal Secure Installation Look for the Wi egand output port WDO green WD1 white and GND black from the ter minal Step Connect the wires from the terminals to AdapTec Plus if you only want to use the system for time at tendance purposes Step O Connect AdapTec Plus to a 12VDC re chargeable backup battery See diagram 1 page 8 for details This is optional Ignore this if you do not need any backup power Step Connect AdapTec Plus to a power source 12VDC 3A WIRING DIAGRAMS D CONVENIENT INSTALLATION Siren Exit Mute Switch AdapTec Plus Exit Button Emergency Pass gece Break Glass Connection Points WIRING DIAGRAMS SECURE INSTALLATION AdapTec Plus Emergency Break Glass Connection Points Connection Points
4. FINGORIEC AD PIEC Plas Installer Guide AD PTEC Pius Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I O function enhanc ing door access control functionalities and easing installation processes AdapTec Plus is an exceptional FingerTec accessory in a small package UNDERSTANDING ADAPTEC PLUS FUNCTIONS Enhanced Security with Encrypted Signals It supports FingerTec encrypted 26 bit Wiegand communication output providing enhanced security level for extra protection Power Up Terminals amp Door Lock Systems A single AdapTec Plus can support a maximum of 2 units of FingerTec terminals and 2 sets of door lock accessories such as the EM lock and drop bolt in one single system installation Prolonged Life Span of Hardware With data encryption the life span of the terminals can be prolonged without the risk of short circuiting when using AdapTec Plus Control IN OUT Terminals at an Entrance AdapTec Plus is a perfect choice for an IN OUT installation where a door is controlled both at the entrance and the exit Supports Rechargeable Backup Battery Connects well to any 12VDC rechargeable backup battery providing power to ensure protection of access during any events of power failure Emergency Alerts with Siren Compatible with an NC siren type with a maximum of 0 5A load for an emergency event e g if the terminal is
5. Switch FingerTec Terminal Push Button FINGERTEC ACCESSORIES For more accessories go to accessory fingertec com HID Card MiFare Card RFID Card ON OFF Keyswitch Contactless Release Button BREAK GLASS gt PRESS HERE s EMERGENEGY DOOR RELEASE Emergency Alarm Siren with Break Glass Release Button Strobe Light MOUNTING AN ADAPTEC PLUS ONTO A WALL Mount the AdapTec Plus on a wall Identify a location to mount the AdapTec Plus on a wall Fix the AdapTec Plus onto the wall by tightening the screws into the 4 holes NOTE Details in this user guide are subject to change Check http product fingertec com for latest product information 2015 Timetec Computing Sdn Bhd All rights reserved Printed in Malaysia 022015
6. being dismantled without authori zation Seamless Integration with FingerTec Terminals Mix and match the FingerTec terminals via AdapTec Plus for a cost effec tive access control system suitable for small and medium sized offices UNDERSTANDING THE TECHNICAL SPECIFICATIONS Input signal 26 bit FingerTec encrypted Weigand signal Output signal 12VDC 0 5A Siren 12VDC 3A EM output NO NC Type door locks Illegal dismantle Yes continuous beeps May opt to output external siren FingerTec terminals system Door unlock timer VR type LED blinks to indicate unlock time in Seconds On Board LED indicators EM LED lit up door lock output is working Status LED lit up CPU is working Battery low LED lit up Battery is low and cut off NOTE Specifications are subject to change Check http product fingertec com for latest product information UNDERSTANDING THE DESIGN AdapTec Plus consists of 2 main modules Power supply power input module Door lock timer amp Power output access control module LED status indicator Power supply power input module This portion is to be connected to a power source with AC110 240V An AC current should be supplied into this side and a 12VDC 3A current will be gen erated as output Ed These two ca
7. bles V and V are default and are connected to the inner part of AdapTec Please do not remove or change these cables Power output access control module amp These cables connect to the 12VDC power from the power supply input module Do not remove or dismantle these cables These cables connect to a 12VDC rechargeable backup battery During a power failure the backup battery will power up AdapTec Plus These are the power output ports from AdapTec Plus Refer to the wiring diagram for details These are the Wiegand data input ports from the FingerTec terminals Refer to the wiring diagram for details OTHER FEATURES You will find a buzzer 4 LED indicators and a door lock timer on the board Check and set each of them accordingly after powering up the system You will hear the buzzer beep to indicate e Unlocked Door Short buzz Door is unlocked and access granted during verification or pressing push release button e Over Voltage Non stop buzzing after startup Over voltage of power input Stop the power supply to the system immedi ately and check the input voltage consult support fingertec com Adjust the door lock timer for a longer or shorter unlocking time period by turning the screw clockwise Count the LED blinks after turning it Each blink represents 1 second and the recommended time period i
8. ride key in case of a system failure or breakdown Wooden Doorframe Wooden Door Drill 3 holes on the wooden door Place the Steel Bar on the door Insert the Silver Nut siyer a on one side and the Allen Se Key Screw on the other side Tighten the screw to lock the Steel Bar onto its position Glass Doorframe U Bracket Ilen Key Screws Steel Bar Allen Key Screws Philip Screw Glass Door Lodge the U Bracket into the upper edge of the glass doorframe Tighten the 4 Allen Key Screws to hold the U Bracket into position Place the Steel Bar on the side of the U Bracket Tighten the Philipp Screws to lock the Steel Bar onto position Doorframe Allen Key Dr 5 Screws 3 Drill 4 holes on the wooden frame Tighten the 4 screws to fix the Alumi num Plate properly on the doorframe Use the Allen Key to tighten the 2 screws at the bottom of the Magnet The Magnet will stick to the Aluminum Plate when the screws are tight ened Use the Allen Key to tighten the other 2 screws on the sides of the Mag net OVERVIEW OF THE WHOLE SYSTEM INSTALLATION E aporte gt 10 Switching ace AC110 240V power supply a Power Input 12VDC _ 12VDC Rechargeable battery es ABOVE CEILING rA ON OFF Keyswitch CEILING e EM Lock T Y OUTDOOR NETWORKING Emergency Break Glass Hub
9. s 5 seconds 5 blinks Select the type of door lock to use NO type or NC type e PIN 1 amp 2 NO Type door lock system e PIN 2 amp 3 NC Type door lock system default The LED lights up to indicate the following e EM lock LED The EM lock system is charged up and working properly e Status LED The overall system is working properly Note Contact support fingertec com if either of the above LED lights are not lit up e Bat Low LED The battery is weak and needs to be charged or replaced DETAILS OF WIRING AdapTec Plus supports 2 types of installations Convenient or Secure You can select between modes by applying different wiring arrangements during installation Under Convenient mode AdapTec Plus will unlock doors imme diately after receiving responses from FingerTec devices This feature is sup ported by all FingerTec models For installations using Secure mode there will be a 1s time delay when un locking the door after verification at FingerTec devices This delay is due to the 26 bit Wiegand transmission of encrypted password from device to AdapTec Plus This is an optional security feature provided by AdapTec Plus for users who favor more security slight delay over convenience no delays AdapTec Plus works with FingerTec terminals via an encrypted Wiegand signal to control the door open close mechanism Please make sure you are using the following FingerTec models that support the encrypted 26 bit Wi egand