Home
User Manual Installation, PoE Injector SPIDER Giga 2TX - e
Contents
1. Operating voltage The operating voltage is not electrically insulated from the PoE voltage Use an external power supply unit that ensures electrical insulation insulation voltage 1500 V L Ground the device before connecting any other cables O Connect solely an operating voltage that corresponds to the type plate of your device L For every operating voltage to be connected verify that the following requirements are met The voltage supply has an easily accessible disconnecting device e g a switch or a plug This disconnecting device is clearly identified So in the case of an emergency it is clear which disconnecting device belongs to which line The power supply cables to be connected are voltage free Relevant for North America The power supply is Class 2 compliant The operating voltage inputs are designed for operation with safety extra low voltage Connect solely SELV circuits with voltage restrictions in line with IEC EN 60950 1 to the operating voltage connections A fuse suitable for DC voltage is located in the plus conductor of the power supply The minus conductor is grounded Regarding the properties of this fuse See General technical data on page 22 The wire diameter of the power supply cable is at least 1 mm North America AWG16 on the input The power supply cables used are permitted for the temperature range required by the use case The power supply cables are suitable for ambient temperatures of up to a
2. ELECTRIC SHOCK Start connecting the operating voltage solely if all the above requirements are fulfilled See Operating voltage on page 5 Failure to follow these instructions can result in death serious injury or equipment damage The operating voltage can be connected redundantly Both inputs are uncoupled There is no distributed load With redundant supply the power supply unit with the higher output voltage supplies the device on its own Installation PoE Injector Release 01 01 2014 17 Note The tightening torque applied to the terminal screws is 5 Ib in 0 56 Nm For the operating voltage to be connected perform the following steps L Pull the terminal block off the device L Connect the power supply lines 2 4 Operating the device A CAUTION ELECTRIC SHOCK Connect solely an operating voltage that corresponds to the type plate of your device Failure to follow these instructions can result in injury or equipment damage LO Mount the terminal block for the operating voltage By connecting the operating voltage via the terminal block you start the operation of the device 2 5 Connecting data cables 1 2 IE a JN Figure 1 The PoE Injector device loops through 1 1 the data paths connected to the pins 1 Data 2 Data PoE Installation PoE Injector 18 Release 01 01 2014 Note In general adhere to the following recommend
3. 1 Unpacking and checking the content of the package LI Check whether the package includes all items named in section Scope of delivery on page 25 L Check the individual parts for transport damage 2 2 Installing and grounding the device A CAUTION TRANSIENT OR ELECTROSTATIC DISCHARGES Do not open the housing Failure to follow these instructions can result in injury or equipment damage 2 2 1 Installing the device onto the DIN rail Note The shielding ground of the connectable twisted pair lines is connected to the ground connection as a conductor To mount the device onto a horizontally mounted 35 mm DIN rail according to DIN EN 60715 proceed as follows L Slide the upper snap in guide of the device into the DIN rail O Press the media module downwards onto the clip in bar LI Snap in the device Installation PoE Injector 14 Release 01 01 2014 Note Verify that there is at least 4 in 10 cm of space above and below the device Verify that there is at least 0 8 in 2 cm of space on the right and left sides of the device 2 2 2 Wall Mount Plate Mounting Follow the steps below to mount the device with the wall mount plates LI To remove the DIN Rail clip from the device unscrew the screws that secure it Align the screw holes of the wall mount plates with the ones of the device Use the screws included to secure the wall mount plates on the device Use the hook holes of the wall mount plates to ha
4. 100 1000 Mbit s PoE port allows you to connect network components such as a powered device PD according to the standards IEEE 802 3 10BASE T 100BASE TX 1000BASE T and IEEE 802 3af at This port supports 1000 Mbit s full duplex 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode Power over Ethernet PoE PoE 1 4 Display elements 1 4 1 Device state These LEDs provide information on the status of the power supply LED Color Activity Meaning P1 Green Lights up The operating voltage 1 is on None The operating voltage 1 is off P2 Green Lights up The operating voltage 2 is on None The operating voltage 2 is off Installation PoE Injector 12 Release 01 01 2014 1 4 2 PoE status PoE a HIRSCHMANN This LED provides information on the PoE status LED Color Activity Meaning PoE Green Lights up The PoE power supply is active None The PoE power supply is inactive Installation PoE Injector Release 01 01 2014 13 2 Installation The devices have been developed for practical application in a harsh industrial environment On delivery the device is ready for operation The following steps should be performed to install and configure a device Unpacking and checking the content of the package Installing and grounding the device Wiring the terminal block for the operating voltage Operating the device Connecting data cables 2
5. fh HIRSCHMANN A BELDEN BRAND User Manual Installation PoE Injector SPIDER Giga 2TX PoE EEC SN Installation PoE Injector Technical support Release 01 01 2014 https hirschmann support belden eu com The naming of copyrighted trademarks in this manual even when not specially indicated should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone 2014 Hirschmann Automation and Control GmbH Manuals and software are protected by copyright All rights reserved The copying reproduction translation conversion into any electronic medium or machine scannable form is not permitted either in whole or in part An exception is the preparation of a backup copy of the software for your own use For devices with embedded software the end user license agreement on the enclosed CD DVD applies The performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document Hirschmann can accept no responsibility for damages resulting fro
6. standard or de facto standard solely if the certification indicator appears on the housing Installation PoE Injector Release 01 01 2014 25 A Further Support Technical Questions For technical questions please contact any Hirschmann dealer in your area or Hirschmann directly You will find the addresses of our partners on the Internet at http Awww hirschmann com Contact our support at https hirschmann support belden eu com You can contact us in the EMEA region at Tel 49 0 1805 14 1538 E mail hac support belden com in the America region at Tel 1 717 217 2270 E mail inet support us belden com in the Asia Pacific region at Tel 65 6854 9860 E mail inet ap belden com Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification The current technology and product training courses can be found at http Awww hicomcenter com Support ranges from the first installation through the standby service to maintenance concepts With the Hirschmann Competence Center you have decided against making any compromises Our client customized package leaves you free to choose the service components you want to use Internet http Awww hicomcenter com Insta
7. to in order to observe the EMC threshold values FCC note This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference 2 this device must accept any interference received including interference that may cause undesired operation Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment The device creates and uses high frequencies and can also radiate high frequencies and if it is not installed and used in accordance with this operating manual it can cause radio transmission interference The use of this device in a living area can also cause interference and in this case the user is obliged to cover the costs of removing the interference Recycling note After usage this device must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county state and country Installation PoE Injector Release 01 01 2014 7 About this Manual The Installation User Manual document contains a device description safety instructions a display description and other information that you require to install the device before starting with the configuration of the dev
8. al length permitted for the twisted pair cables connected to port 1 and port 2 is a maximum of 109 yards 100 m Power consumption power output at 24 V DC Maximum Power output power consumption max 33 8 W with PoE 115 4 Btu IT h 24 Installation PoE Injector Release 01 01 2014 Scope of delivery Number Article 1x Device Order number x 6 pin pluggable terminal block for redundant power supply x Wall mounting set x Installation user manual Device Order number SPIDER Giga 2TX PoE EEC 942 059 001 Accessories Other accessories Order number Rail Power Supply RPS60 48V EEC 943 952 001 Rail Power Supply RPS 80 EEC 943 662 080 Underlying norms and standards Name UL 508 CSA C22 2 No 142 EN 61000 6 2 EN 61000 6 4 FCC 47 CFR Part 15 IEEE 802 3 IEEE 802 3af IEEE 802 3at Safety for Industrial Control Equipment Canadian National Standard s Process Control Equipment Industrial Products Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments Electromagnetic compatibility EMC Part 6 4 Generic standards Emission standard for industrial environments Code of Federal Regulations Ethernet Power over Ethernet Power over Ethernet Plus Table 3 List of norms and standards The device generally fulfills the norms and standards named in their current versions The device has a certification based on a specific
9. ations for data cable connections in environments with high electrical interference levels LI Keep the length of the data cables as short as possible LI When using copper cables verify that there is a sufficient gap between the power supply cables and the data cables when laid over a long distance Ideally install the cables in separate cable channels O Use shielded cables Installation PoE Injector Release 01 01 2014 19 3 Maintenance and service When designing this device Hirschmann largely avoided using wear parts The parts subject to wear and tear are dimensioned to last longer than the lifetime of the product when it is operated normally Operate this device according to the specifications see on page 22 Technical data Depending on the degree of pollution in the operating environment check at regular intervals that the ventilation slots in the device are not obstructed Note You will find information about the complaints and returns procedures in the Internet under http www beldensolutions com en Service Repairs index phtml Installation PoE Injector 20 Release 01 01 2014 4 Disassembly Note Disconnect the grounding soley after disconnecting all other cables L Disconnect the data lines L Disable the operating voltage LI Remove the power connector from the device L Disconnect the grounding 4 1 Removing the device from the DIN rail L To remove the device from the DIN rail press the device
10. downwards and pull it out from under the DIN rail Figure 2 Removal from the DIN rail Installation PoE Injector Release 01 01 2014 21 5 Technical data General technical data Dimensions See Dimension drawing on page 23 WxHxD Weight 4 6 lb 420 g Power supply 2 voltage inputs for redundant voltage supply Safety extra low voltage SELV redundant inputs disconnected Relevant for North America Class 2 Rated voltage range DC 24V 48V Voltage range DC incl maximum 21V 53 V tolerances Connection type 6 pin pluggable terminal block for redundant power supply Current consumption at 24VVDC max 1 5 A with PoE Overload current protection at input Back up fuse per voltage input min 3 5 A Peak inrush current 15V for 1 ms Climatic conditions Ambient air temperature 40 F 158 F 40 C during operation 70 C Humidity 5 95 non condensing Air pressure up to 2187 2 yd 2000 m 795 hPa Climatic conditions Ambient air temperature 4 F 140 F 45 C 85 C during storage Humidity 5 95 non condensing Air pressure up to 2187 2 yd 2000 m 795 hPa Pollution degree 2 Protection classes Degree of protection IP 30 a As an alternative to the back up fuse is possible o Voltage supply according to Class 2 or EN 60950 1 Limited Power Source b Temperature of the ambient air at a distance of 2 inches 5 cm from the device c Temperature of
11. ice Legend The symbols used in this manual have the following meanings Listing O Work step Subheading Installation PoE Injector 8 Release 01 01 2014 1 Description 1 1 General device description The PoE Injector devices are designed for the special requirements of industrial automation They meet the relevant industry standards provide very high operational reliability even under extreme conditions and also long term reliability and flexibility The PoE Injector device is a power sourcing equipment PSE Through a twisted pair cable connected to the 10 100 1000 Mbit s PoE port the device provides power for a powered device PD such as a WLAN access point an IP camera or an IP telephone With the presence of the PoE power supply a separate power supply for the powered device is unnecessary The following installation options are available simply snapping them onto a DIN rail Mounting on a vertical flat surface The devices work without a fan The Hirschmann network components help you ensure continuous communication across all levels of the company Installation PoE Injector Release 01 01 2014 9 E Application Examples PoE connection Data PoE 1000 Mbit s Ethernet connection Data 100 Mbit s Ethernet connection Data 10 Power Input Server Ethernet Switch without PoE Power Input functionality PoE Injector Power Input PoE Injec
12. llation PoE Injector 26 Release 01 01 2014 Installation PoE Injector Release 01 01 2014 27 fh HIRSCHMANN A BELDEN BRAND
13. ls the hazard of physical injury or significant damage to property Before connecting any cable read this document and the safety instructions and warnings See Operating voltage on page 17 The proper and safe operation of this device depends on proper handling during transportation proper storage and assembly and conscientious operation and maintenance procedures Operate the device with undamaged components exclusively Qualification requirements for personnel O Allow qualified personnel exclusively to perform any work on the device Qualified personnel are characterized by the following points The qualified personnel are properly trained Proper training as well as a practical knowledge and experience constitute the qualification This qualification is the requirement to connect to ground and to label power circuits devices and systems in accordance with current safety engineering standards The qualified personnel are aware of the hazards associated with his tasks The qualified personnel know proper measures against such hazards to minimize the risk for themselves and others The qualified personnel participate in training regularly Certified usage O Use the device solely for the application cases described in the Hirschmann product information including this manual Operate the device solely according to the technical specifications See Technical data on page 22 Installation PoE Injector 4 Release 01 01 2014
14. m the use of the network components or the associated operating software In addition we refer to the conditions of use specified in the license contract You can get the latest version of this manual on the Internet at the Hirschmann product site www hirschmann com Printed in China Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Germany Tel 49 1805 141538 Installation PoE Injector Contents 1 1 1 2 1 3 1 4 2 1 2 2 2 3 2 4 2 5 Safety instructions About this Manual Legend Description General device description Device view Ethernet ports 1 3 1 10 100 1000 Mbit s twisted pair port 1 3 2 10 100 1000 Mbit s PoE port Display elements 1 4 1 Device state 1 4 2 PoE status Installation Unpacking and checking the content of the package Installing and grounding the device 2 2 1 Installing the device onto the DIN rail 2 2 2 Wall Mount Plate Mounting 2 2 3 Grounding the device Wiring the terminal block for the operating voltage Operating the device Connecting data cables Maintenance and service Disassembly Removing the device from the DIN rail Technical data Further Support Installation PoE Injector Release 01 01 2014 11 11 12 12 12 13 14 14 14 14 15 16 17 18 18 20 21 21 22 26 Safety instructions General safety instructions You operate this device with electricity Improper usage of the device entai
15. ng the device on the wall To remove the wall mount plates reverse the steps above O OOO Installation PoE Injector Release 01 01 2014 15 mm incl 7 16 028 063 s Z 159 8 6 29 2 2 3 Grounding the device The device has a functional ground connection The device is grounded via the separate ground screw Note Ground the device before connecting any other cables Note The shielding ground of the connectable twisted pair lines is connected to the ground connection as a conductor L Ground the device via the ground screw Installation PoE Injector 16 Release 01 01 2014 2 3 Wiring the terminal block for the operating voltage A WARNING ELECTRIC SHOCK Never insert pointed objects narrow screwdrivers wires etc into the device or into the connection terminals for electric conductors Do not touch the connection terminals Failure to follow these instructions can result in death serious injury or equipment damage Figure Pin assignment on the device Specification of the operating voltage Power supply connection 2 0 V minus Rated voltage range DC terminal VV BV Power supply connection 2 24 48 V Voltage range DC incl plus terminal maximum tolerances QCA AV BV Power supply connection 1 0 V minus terminal 6 Power supply connection 1 24 48 V plus terminal Table 2 Pin assignment 6 pin pluggable terminal block Operating voltage A WARNING
16. nt temperatures gt 140 F 60 C The surfaces of the device housing may become hot Avoid touching the device while it is operating Hou 00 o National and international safety regulations Verify that the electrical installation meets local or nationally applicable safety regulations CE marking The labeled devices comply with the regulations contained in the following European directive s 2011 65 EU RoHS Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2004 108 EC EMC Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility In accordance with the above named EU directive s the EU conformity declaration will be at the disposal of the relevant authorities at the following address Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Germany Tel 49 1805 141538 Installation PoE Injector Release 01 01 2014 The device can be used in the industrial sector Interference immunity EN 61000 6 2 Emitted interference EN 61000 6 4 Warning This is a class A device This device can cause interference in living areas and in this case the operator may be required to take appropriate measures Note The assembly guidelines provided in these instructions must be strictly adhered
17. t least 167 F 75 C For the wires of the power supply cables use copper wire exclusively Start connecting the operating voltage solely if all the above requirements are fulfilled L The device is free of any service components Internal fuses are triggered solely in the case of a detected fault in the device In case of damage or malfunction of the device turn off the operating voltage and return the device to the plant for inspection Shielding ground The shielding ground of the connectable twisted pair lines is connected to the ground connection as a conductor L Beware of possible short circuits when connecting a cable section with conductive shielding braiding Installation PoE Injector Release 01 01 2014 5 Housing Only technicians authorized by the manufacturer are permitted to open the housing The device is grounded via the separate ground screw L Never insert pointed objects narrow screwdrivers wires etc into the device or into the connection terminals for electric conductors Do not touch the connection terminals Verify that the electrical installation meets locally or nationally applicable safety regulations Keep the ventilation slits free to ensure good air circulation Verify that there is at least 4 in 10 cm of space above and below the device Verify that there is at least 0 8 in 2 cm of space on the right and left sides of the device Install the device in the vertical position At ambie
18. the ambient air at a distance of 2 inches 5 cm from the device Installation PoE Injector 22 Release 01 01 2014 Dimension drawing mm inch m psia i Lg 140 5 51 47 05 1 85 i 30 95 1 18 3 74 104 4 09 Figure 3 Dimensions SPIDER Giga 2TX PoE EEC Installation PoE Injector Release 01 01 2014 EMC and immunity EMC interference emission Radiated emission FCC 47 CFR Part 15 EN 61000 6 4 Conducted emission FCC 47 CFR Part 15 EN 61000 6 4 EMC interference immunity Electrostatic discharge EN 61000 4 2 Contact discharge IEEE C37 90 3 EN 61000 4 2 Air discharge IEEE C37 90 3 Electromagnetic field EN 61000 4 3 80 MHz 1000 MHz EN 61000 4 3 1 4 GHz 2 GHz EN 61000 4 3 2 GHz 2 7 GHz Fast transients burst EN 61000 4 4 DC supply connection IEEE C37 90 1 EN 61000 4 4 Data line IEEE C37 90 1 Voltage surges DC supply connection EN 61000 4 5 line ground EN 61000 4 5 line line Conducted disturbances EN 61000 4 6 150 kHz 80 MHz Stability IEC 60068 2 6 test Fc Vibration IEC 60068 2 27 TestEa Shock Network range Class A Fulfilled Class A Fulfilled 4kV 8kV 10 V m 3 V m 1 V m 2kV 1kV 0 5 kV 0 5 kV 10 V 3 Hz 9 Hz with 0 14 in 3 5 mm amplitude 9 Hz 150 Hz with 0 04 oz 1 g 0 53 oz 15 g at 11 ms The tot
19. tor Power Input PoE Injector Power Input PoE Injector SPIDER PD Installation PoE Injector Release 01 01 2014 1 2 Device view 2 1 ead 3a _ 3 3b H HIRSCHMANN 1 Grounding screw 2 6 pin terminal block for the operating voltage 3a LED display element Power Supply P1 3b LED display element Power Supply P2 4 Port 1 RJ45 socket for 10 100 1000 Mbit s twisted pair port 5 LED display element PoE status 6 Port2 RJ45 socket for 10 100 1000 Mbit s PoE port Table 1 Device view 1 3 Ethernet ports The PoE Injector device supplies voltage to the twisted pair cables via the wire pairs carrying the signal phantom voltage and passes the data paths through 1 1 to the connected to the pins 1 3 1 10 100 1000 Mbit s twisted pair port The socket housing is electrically connected to the front panel This port is an RJ45 socket Installation PoE Injector Release 01 01 2014 11 The 10 100 1000 Mbit s twisted pair port offers you the ability to connect network components according to the IEEE 802 3 10BASE T 100BASE TX 1000BASE T standard This port supports 1000 Mbit s full duplex 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode 1 3 2 10 100 1000 Mbit s PoE port The socket housing is electrically connected to the front panel This port is an RJ45 socket The 10
Download Pdf Manuals
Related Search
Related Contents
Pajemploi - Les Titounets DH 27 DH 27 M EA781BG-50 LED作業ライト【マグネット式】取扱説明書 Tassenwärmer / Cup warmer Manual ECOSS Extraits de activités spontanées detector mecánico de calor serie 5600 circuito único: 5601p Moxi Fit - North Guide Utilisateur SANYO DP42848/DP46848 user manual Copyright © All rights reserved.